MT106-101
SCAN DOUBLER CARD FOR
TM
MULTI-TASKER USER’S GUIDE




Please read this manual carefully before using your MT106-101. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MT106-101 and to prevent fire and shock hazard. Please read them carefully and heed all warnings.



The MT106-101 is a Scan Doubler Card designed for use with the Multi-Tasker system. When installed in a Multi-Tasker enclosure, this card allows the connection of an S-Video or one of three Composite Video (NTSC/PAL) sources to a data- grade monitor or projector. The MT106-101 doubles the scan rate from 15.7 kHz to 31.5 kHz, while converting the interlaced broadcast video type signal to a non-interlaced VGA-type signal. The selection of an input source is accomplished by RS-232 control through the Multi-Tasker enclosure.

A/V presentation systems often require the use of monitors that are designed specifically to handle computer video signals. The MT106-101 allows the integration of composite video or S-Video into these systems. The MT106-101 can also help to simplify systems that would otherwise require switching between video and RGB inputs on a projector or large screen display. Furthermore, the MT106-101 improves the quality of a composite video signal, resulting in a steadier image with higher definition.

The MT106-101 provides a number of features that can be controlled via RS-232 through the Multi- Tasker Basic Enclosure. These features include controls for horizontal and vertical positioning, horizontal and vertical sizing, black level, color, contrast and brightness.
The MT106-101 offers 3 composite video inputs on female BNC connectors and an S-Video input on a standard 4-pin mini-DIN connector. The latter may be adapted to 2 BNC connectors using ALTINEX adapter cables. The MT106-101 output is provided on a 15-pin HD female (VGA-type) computer video connector. This output may also be easily adapted to 5 BNC connectors for RGBHV using an ALTINEX adapter cable. Using the MT104-101 8-in Video Switcher expansion cards, up to 32 additional composite inputs can be connected internally to the MT106-101, and controlled via RS-232 control to the Multi-Tasker enclosure.






Application 1 · Application 2


![Page 8 of the Altinex MT106-101 user manual — 1. [VER]](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/page-8.webp?w=400)
After processing a command, an OK or ER string will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero.
Each command consists of three parts: function, card ID, and unit ID. [Function, Card ID, Unit ID].
Example:
VER = Function C3 = Card ID U2 = Unit ID
For Function, see a detailed explanation under each command description.
The Card ID is an assigned value from 1 to 19, based on which slot the card is put in. The Card ID 0 (C0) is used for the controller (see user’s guide for the MT100-100). Changing the position of a card will significantly affect the commands recorded on software definitions or a third party control system.
The Unit ID has a value from 0 to 9. The Unit ID 0 should be used for single unit operation. If the Unit ID is set to 0, then each command can be used without Ui (use command [SETU0]; see user’s guide for the MT100-100).
7.1 RS-232 CONTROL
When used in the Multi-Tasker™ Basic Enclosure, the MT106-101 has many advanced remote control capabilities, which are accessible through standard RS-232 communication. The actual control may be accomplished through a computer control system or any other device capable of sending RS-232 commands.
Example: [VERC3]: for unit ID zero [VERC3Ui]: for unit ID other than zero [VERC3]: equivalent to [VERC3U0]
7.1.1 RS-232 INTERFACE
This command displays the software version and card type for the Scan Doubler card.
The RS-232 commands for the MT106-101 are in a simple ASCII character format.
Cn = card ID No. (n = slot # from 1 to 19)
![Page 9 of the Altinex MT106-101 user manual — [ON0C4U2]](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/page-9.webp?w=400)
Ui = Unit ID (i = # from 0 to 9) (refer to the MT100-100 user’s guide for explanation)
This command resets the card configuration to factory defaults.
Example: If one Scan Doubler Card is in slot #2 of unit 3. Send the command [VERC2U3], and the Multi-Tasker™ Basic Enclosure will return the following:
Ci = card ID (n = a slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)
Example:
MT106-101 = card type 690-0155-003 = software version
There is an MT106-101 in slot 4 of unit 0. All controls are set to various levels and the output is in PAL mode. Sending the command [CLRC4] will set the level controls to their default values and place the output in NTSC format.
This command receives the status of the card.
Cn = card ID (n = a slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)
The ON command selects one of four possible input sources to connect to the output.
Ui = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)
Example: If there is one MT106-101 card in slot #2 of unit 3 set for NTSC outputs, sending the command [C2U3] to the Multi-Tasker™ will yield the following feedback:
INPUT: 640x480 = Input resolution OUTPUT: NTSC = Output mode C02 = card is in slot 2
n = value from 0 to 3
If there is no card in slot #2 of unit 3, sending the [C2U3] command will not return any feedback from either card.
Example: Connect the S-Video signal input on the MT106-101 located in slot 4 of unit ID 2 to the VGA output connector.
The Signal Present command tests for the presence of a signal on the input. After sending the command, the feedback will be either "1" signifying a signal is present, or "0" indicating no signal was detected.
These commands allow the user to increase or decrease the value of the selected attribute. They must be used immediately following one of the following STATUS commands.
Ci = card number
Example: To check for the presence of an input signal on card 4, send the command [SIGC4] and verify
feedback of "1" or "0".
![Page 10 of the Altinex MT106-101 user manual — [HPOSC4U1] 10](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/page-10.webp?w=400)
![Altinex MT106-101 — [HPOSC4U1] 10 diagram (page 10)](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/fig-10-1.webp)
Example: There is an MT106-101 in slot 7 of unit ID 4. Set the Horizontal Position to the maximum value of 20 by sending the command [HPOS20C7U4].
This command selects the Horizontal Position adjustment and makes it the active control. It is also used to return the status of the current Horizontal Position. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Attempting to cycle past the minimum or maximum values will have no effect on the attribute's value.
Any command other than [ + ] or [ - ] will reset the previous selection and the STATUS command will need to be reissued.
Example: There is an MT106-101 in slot 4 of unit ID 1. View the current Horizontal Position and adjust for the best image.
Example: There is an MT106-101 in slot 4 of unit ID 2. The current Horizontal Position is set to a value of 10. Use the [ + ] and [ - ] controls to find the best horizontal position. Starting from 10, first increment the value to 12. Next, decrement the value back down to 8 for the best picture.
[HPOSC4U1] = STATUS command 10 = Feedback of current value [ + ] & [ - ] = Adjust as required
[HPOSC4U2] 10 [ + ][ + ][ - ][ - ][ - ][ - ]
[HPOSC4U2] = STATUS/Current value 10 = Feedback of current value [ + ][ + ] = Increment twice to 12 [ - ][ - ][ - ][ - ] = Decrement 4 times to 8 [HPOSC4U2] = STATUS/Current Value 8 = Feedback of new value
This command sets the Vertical Position to an absolute value and makes the Vertical Position adjustment the active control.
This command sets the Horizontal Position to an absolute value. It also makes the Horizontal Position adjustment the active control.
Example: There is an MT106-101 in slot 2 of unit ID 3. Set the Vertical Position to the value of 12 by sending the command [VPOS12C2U3].
![Altinex MT106-101 — [HPOSC4U1] 10 diagram (page 10)](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/fig-10-2.webp)
![Page 11 of the Altinex MT106-101 user manual — [VSIZEC2U3] 10](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/page-11.webp?w=400)
This command selects the Vertical Position adjustment and makes it the active control. It also returns the status of the current Vertical Position. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Example: There is an MT106-101 in slot 2 of unit ID 3. View the current Horizontal Size and adjust the image to the center of the screen.
[HSIZEC2U3] = STATUS/Current value 10 = Feedback of current value [ + ] & [ - ] = Adjust as required
Example: There is an MT106-101 in slot 2 of unit ID 3. View the current Vertical Position and adjust the image for the best vertical position.
This command sets the Vertical Size to an absolute value and makes the Vertical Size adjustment the active control.
[VPOSC2U3] = STATUS/Current value 10 = Feedback of current value [ + ] & [ - ] = Adjust as required
Example: There is an MT106-101 in slot 1 of unit ID 1. Set the Vertical Size to the value of 6 by sending the command [VSIZE6C1U1].
This command sets the Horizontal Size to an absolute value and makes the Horizontal Size adjustment the active control.
This command selects the Vertical Size adjustment and makes it the active control. It also returns the status of the current Vertical Size. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Example: There is an MT106-101 in slot 2 of unit ID 3. Set the Horizontal Size to the value of 12 by sending the command [HSIZE12C2U3].
This command selects the Horizontal Size adjustment and makes it the active control. It also returns the status of the current Horizontal Size. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Example: There is an MT106-101 in slot 2 of unit ID 3. View the current Vertical Size and adjust the vertical size for the best fit.
[VSIZEC2U3] = STATUS/Current value 10 = Feedback of current value [ + ] & [ - ] = Adjust as required
![Page 12 of the Altinex MT106-101 user manual — [BRIGC2U3] 2](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/page-12.webp?w=400)
This command selects the Brightness adjustment and makes it the active control. It also returns the status of the current Brightness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Example: There is an MT106-101 in slot 4 of unit ID 2. Set the Sharpness to the value of 2 by sending the command [SHARP2C4U2].
This command selects the Sharpness adjustment and makes it the active control. It is also used to return the status of the current Sharpness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Example: There is an MT106-101 in slot 4 of unit ID 2. Set the Brightness to the value of 2 by sending the command [BRIG2C4U2].
This command selects the Brightness adjustment and makes it the active control. It is also used to return the value of the current Brightness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Example: There is an MT106-101 in slot 2 of unit ID 3. View the current Sharpness and adjust the sharpness for a clean, clear image.
[SHARPC2U3] = STATUS/Current value 2 = Feedback of current value [ + ] & [ - ] = Adjust as required
Example: There is an MT106-101 in slot 2 of unit ID 3. View the current Brightness and adjust the brightness for a good image.
The COLOR command sets the Color to an absolute value. It also makes the Color adjustment the active control.
[BRIGC2U3] = STATUS/Current value 2 = Feedback of current value [ + ] & [ - ] = Adjust as required
This command sets the Sharpness to an absolute value. It also makes the Sharpness adjustment the active control.
Example: If there is an MT106-101 in slot 4 of unit ID 2, the color may be set to a value of 2 by sending the command [COLOR2C4U2].
![Page 13 of the Altinex MT106-101 user manual — 24. [WR]](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/page-13.webp?w=400)
The COLOR command, with no value, selects the Color adjustment and makes it the active control. It is also used to return the status of the current Color level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
Example: There is an MT106-101 in slot 2 of unit ID 3. View the current Hue and set the hue for a good image.
[HUEC2U3] = STATUS/Current value 2 = Feedback of current value [ + ] & [ - ] = Adjust as required
Example: There is an MT106-101 in slot 2 of unit ID 3. View the current Color level and adjust the color for the best possible picture.
In MTSetup.exe, this command displays a list of the commands available for the MT106-101 along with a brief description.
[COLORC2U3] = STATUS/Current value 2 = Feedback of current value [ + ] & [ - ] = Adjust as required
This command sets the Hue to an absolute value. It also makes the Hue adjustment the active control.
This command groups multiple cards in the Enclosure. Each unit contains a maximum of nine groups.
Cn = card ID No. (n = slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)
Example: An MT106-101 is in slot 4 of unit ID 2. Set the Hue to the value of 7 by sending the command [HUE7C4U2].
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
Example: To group cards #1, 2, and 3 as group 5 of unit #1, send the command [WRC1C2C3G5U1]. After executing this command, cards 1, 2 and 3 will be grouped together as group 5 of unit 1.
This command selects the Hue adjustment and makes it the active control. It is also used to return the value of the current Hue level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.
![Page 14 of the Altinex MT106-101 user manual — 27. [RD]](/cdn/reader/66/666c18634551a9a772534fdf96f5833781cdc5814ff04dc6cca7cf70da2343a6/images/page-14.webp?w=400)
C1C2C19 G5U1.
This command clears the members for a single group or for all nine groups.
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
Example: 1) To clear group #1, send the [CLRG1U1] command. This command clears the members for the specified group only.
This command is used to request group data. With the command, the user can identify which input or output of a particular group is on.
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
Example: In unit ID0, if group 1 has DA Cards with outputs 1 and 2 on, while group 2 has SW Cards with input 2 on:
[G1]: will return feedback as ON12 G1U0. [G2]: will return feedback as ON2 G2U0.
This command displays the members in each group.
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
member = C1 - C19 (card 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)
Example: The cards in slots 1, 2 and 19 are part of group 5 in unit 1. Read the member data for group 5 of unit 1, by sending the command [RDG5U1]. The system will return feedback as follows:

sockets. If the LED is still blinking red, see Cause 2.
We have carefully tested and have found no problems in the supplied MT106-101; however, we would like to offer suggestions for the following:
Cause 2: The card and its serial device are not communicating.
again. If there is still an error, see Cause 3.
Cause 1: Card cage is not plugged in.
Solution: Plug the card cage in. If the LED lights, the problem is solved. If the LED is still not ON, see Cause 2.
all the way into the slot. If there is still an error, see Solution 2.
Cause 2: Card is not plugged in all the way.
again. If there is still an error, see Solution 3.
Solution: Push the card in all the way. If the LED is still not ON, see Cause 3.
Solution 3: Call ALTINEX at (714) 990-2300.
Cause 3: Card cage slot has a problem.
Cause 1: The source has a problem.
card cage. If the slot was damaged, the card may work in other slots. If other slots work and the LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2.
Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2.
Cause 2: The card output is not selected.
Solution: Select the card output. See RS-232 accessible commands in Section 7. If no display is present, see Cause 3.
with an LED and verify that the slot used is good by seeing if the other card’s LED lights in that slot. If it lights, then the original card may be the source of the problem. Call ALTINEX at (714) 990-2300.
Cause 3: Cable connections are incorrect.
Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4.
Cause 1: The CPU on the card is not working properly.
Cause 4: The display has a problem.
Solution: Make sure the display has power and is turned ON. If there is still no display, please call Altinex at (714) 990-2300.
there is no damage. If there is no damage, see Solution 2.

9.1 LIMITED WARRANTY/RETURN POLICY
Please see the Altinex website at www.altinex.com for details on warranty and return policy.