Page 1 of the Furuno CI-80 user manual — DOPPLER SONAR  CURRENT INDICATOR
Page 1 · click to enlarge
Page 1
Furuno CI-80 diagram (page 1)
Fig. 1
Furuno CI-80 diagram (page 1)
Fig. 2

DOPPLER SONAR CURRENT INDICATOR

Furuno CI-80 — DOPPLER SONAR  CURRENT INDICATOR diagram (page 1)
Fig. 3
Page 2 of the Furuno CI-80 user manual
Page 2 · click to enlarge
Page 2

Your Loc al A gent/Deal er

9. 5 2 , A s h i h a r a - c h o , N i s h i n o m i y a , J a p a n
Tel ephone0798652111 Tel efax : 0798654200
FIRST EDITIONFEB. 1995 F : JAN. 6, 2001 Printed in Japan

All rights reserved.

PUB. No. OME-72390 CI- 80 (DAMI)

Furuno CI-80 diagram (page 2)
Fig. 4
Page 3 of the Furuno CI-80 user manual — CAUTION
Page 3 · click to enlarge
Page 3

SAFETY INSTRUCTIONS

WARNING

WARNING

Keep heater away from equipment.

ELECTRICAL SHOCK HAZARD Do not open the equipment.

A heater can melt the equipment’s power cord, which can cause fire or electrical shock.

Only qualified personnel should work inside the equipment.

Use the proper fuse.

Immediately turn off the power at the switchboard if water leaks into the equipment or something is dropped in the equipment.

Fuse rating is shown on the equipment. Use of a wrong fuse can result in equip- ment damage.

Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO agent for service.

Do not operate the equipment with wet hands.

Electrical shock can result.

Do not disassemble or modify the equipment.

Fire, electrical shock or serious injury can result.

CAUTION

Do not place liquid-filled containers on the top of the equipment.

A warning label is attached to the equipment. Do not remove the label. If the label is missing or damaged, contact a FURUNO agent or dealer.

Fire or electrical shock can result if a liquid spills into the equipment.

NameWarning Label (1) Type: 86-003-1011-0 Code No.: 100-236-230

Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire.

Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO agent for service.

Make sure no rain or water splash leaks into the equipment.

Fire or electrical shock can result if water leaks in the equipment.

Page 5 of the Furuno CI-80 user manual — Ship’s Speed (Here, speed is a vector value including velocity and direction.)
Page 5 · click to enlarge
Page 5

PRINCIPLE OF MEASUREMENT

PRINCIPLE OF MEASUREMENT, FEATURES

When a moving vessel emits an acoustical pulse into the water at an angle, a portion of emitted energy is reflected from the seabed and other microscopic objects in the sound path, such as plankton or air bubbles. The frequency of the received signal is shifted from the transmitted frequency in proportion to relative velocity between the vessel and underwater reflecting objects. This is called Doppler Effect.

The CI-80 calculates and displays movements of ship and currents at specific depths by measuring Doppler shifts obtained from three separate directions.

Frequency of reflected signal is shifted in proportion to relative speed between the vessel and reflecting objects.

Ship’s Speed (Here, speed is a vector value including velocity and direction.)

Depending on the base of measurement, ship’s speed is expressed in two ways:

Ground tracking speedShip’s speed and course relative to (Absolute speed) seabed (fixed base)

Water tracking speed: Ship’s speed and course relative to (Relative speed) water layer just below the vessel (floating base)

Nav-aided speedShip’s speed and course obtained (Absolute speed) by external navigation equipment (GPS)

Planktonic layer · Seabed

Page 6 of the Furuno CI-80 user manual — Tide
Page 6 · click to enlarge
Page 6

Nav-aided speed (Pseudo ground tracking speed)

:Base of measurement

Tide

Tide is movement of watermass at a particular depth.

To know absolute tide (speed on ground), the following two data are required:

1 Ship’s speed and course based on ground

2 Ship’s speed and course based on measuring layer (A)

Absolute tide is, then, given as a difference of these two speed vectors.

Absolute Tide = 1 – 2

:Base of measurement

Show 7 more labels / short text on this page
GPS satellites · Water tracking speed · Near-surface layer · Ground tracking speed · Fixed · Layer (A) · Fixed
Page 7 of the Furuno CI-80 user manual — Tide Differential
Page 7 · click to enlarge
Page 7

Nav Tide

Nav-Tide is an absolute movement of watermass at a particular depth, taking speed information from the external navigator (GPS) as a pseudo ground tracking speed.

To calculate Nav-tide, the following two data are required:

1 Ship’s speed and course obtained by external navigation equipment (GPS)

2 Ship’s speed and course based on measuring layer (A)

Nav-tide is, then, given as a difference of these two speed vectors.

Absolute Tide = 1 – 2

Nav-aided speed (Pseudo ground tracking speed)

:Base of measurement

Tide Differential

Tide differential is a relative movement of tides at different depths, layer (A) and layer (B).

To calculate tide differential, the following two data are used:

1 Ship’s speed and course based on layer (A)

2 Ship’s speed and course based on layer (B)

Tide differential between two layers is, then, given as a difference of these two speed vectors.

GPS satellites · Water tracking speed · Layer (A)

Page 8 of the Furuno CI-80 user manual — Tide (Absolute tide)
Page 8 · click to enlarge
Page 8

Tide Difference = 1 - 2 (Movement of layer B based on

= 2 - 1 (Movement of layer A based on

Layer (B) :Base of measurement

TIDE, NAV-TIDE & TIDE DIFFERENTIAL

Tide (Absolute tide)

Absolute tide can be measured in the ground tracking mode.

10 NM (1 hour trip)

(Moving at 10 kt on ground)

(Moving at 3 kt on ground)

:Base of measurement

Assume that the ship and layer A are moving in the same direction, and ship’s speeds based on ground (Vg) and on layer A (Vwa) are measured as;

Vg = 10 kt (Ship’s speed based on ground)

Vwa = 7 kt (Ship’s speed based on layer A).

Show 8 more labels / short text on this page
layer A) · or · layer B) · Layer (A) · Start of trip · End of trip · Layer A · Fixed
Page 9 of the Furuno CI-80 user manual — Tide Differential
Page 9 · click to enlarge
Page 9

Speed of layer A based on ground (C1) can be calculated as follows:

C1 = Vg – Vwa

= 10 – 7

Nav-Tide (Absolute tide)

Absolute tide can be measured in the nav-aided mode.

Nav-aided ship’s speed (Vn) is equivalent to ship’s ground tracking speed in the ideal conditions. That is, the nav-tide can be calculated by simply replacing Vg with Vn in the above equation.

Tide Differential

Tide differential is a relative movement of tides at different depths.

It can be measured in the ground tracking, water tracking and nav-aided modes.

10 NM (1 hour trip)

:Base of measurement

Show 9 more labels / short text on this page
= 3 (kt) · Start of trip · End of trip · Layer A · (Moving) · Layer B · (Moving) · 2 kt · 5 kt
Page 10 of the Furuno CI-80 user manual — Tide differential calculations in ground tracking mode
Page 10 · click to enlarge
Page 10

Assuming that the ship, layer A and layer B are moving in the same direction, and ship’s speeds based on layer A (Vwa) and on layer B (Vwb) are measured as;

Vwa = 8 kt (Ship’s speed based on layer A)

Vwb = 5 kt (Ship’s speed based on layer B)

Tide differential calculations in ground tracking mode

As an absolute ship’s speed (Vg) is available in the ground tracking mode, tide speeds of layer A (C1) and layer B (C2) based on ground are calculated as follows:

C1 = Vg - Vwa (Speed of layer A based on ground)

C2 = Vg - Vwb (Speed of layer B based on ground)

Thus, the tide differential (Cd) between layer A and layer B is;

Cd = C2 - C1 = (Vg - Vwb) - (Vg - Vwa) = Vwa - Vwb = 8 - 5 = 3 (kt)

Tide differential based on layer A

Speed of layer B viewed from layer A

Cd = C1 - C2 = (Vg - Vwa) - (Vg - Vwb) = Vwb - Vwa = 5 - 8 = -3 (kt)

Tide differential based on layer B

Speed of layer A viewed from layer B

In the water tracking mode, watermass just below the transducer (near-surface layer) is taken as the base of all measurements (virtual ground). Therefore, the ship and tide speeds in the water tracking mode are not absolute but relative to this near-surface layer.

Vw = 9 kt (Ship’s speed based on near-surface layer)

Vwa = 8 kt (Ship’s speed based on layer A)

Vwb = 5 kt (Ship’s speed based on layer B)

or

Page 11 of the Furuno CI-80 user manual — TIDE, NAV-TIDE & TIDE DIFFERENTIAL
Page 11 · click to enlarge
Page 11

10 NM (1 hour trip)

:Base of measurement Layer A

1 kt Assume that the ship and all measuring layers are moving in the same direction, but at different speeds.

Show 6 more labels / short text on this page
Start of trip · End of trip · Near- surface layer · Layer B · 2 kt · 5 kt
Page 12 of the Furuno CI-80 user manual — SETTING SHIP’S HEADING
Page 12 · click to enlarge
Page 12

[READ THIS FIRST!!]

IMPORTANT NOTICE ON TIDE MEASUREMENTS

(In the nav-aided mode, tide accuracy depends heavily on gyro accuracy.)

SETTING SHIP’S HEADING

The CI-80 has the nav-aided mode to measure absolute tides even in deep waters where ground tracking is unattainable. To achieve reliable measurements, however, you must supply accurate heading (gyro) information and ship’s position (or speed/course) data to the CI-80.

If you are going to use the nav-aided mode, set the reading of the AD converter (gyro interface) exactly with that of the master gyrocompass.

1. Confirm that the gyrocompass has settled and all the necessary compensations (latitude compensation, weather compensation, etc.) are made correctly.
2. Operate the AD converter to obtain the same reading as you read on the master gyrocompass. (Do not make adjustment while the ship is turning.)
Furuno CI-80 — SETTING SHIP’S HEADING diagram (page 12)
Fig. 5

AD Converter (Gyro Interface)

If the gyro reading is accurate, the CI-80 should provide accurate tide information. If the gyro data contains some error, however, you may see the following symptoms.

  • Set/drift information on the nav-aided mode differs from that on the ground-tracking mode.
  • Tide/tide differential information on the nav-aided mode differs from that on the ground-tracking mode.

Procedure · Master Gyrocompass

Page 13 of the Furuno CI-80 user manual — IMPORTANT NOTICE ON TIDE MEASUREMENTS
Page 13 · click to enlarge
Page 13

0 10 20 10 20

0 10 20 10 20

0.2 kt

0.5 kt

NAV Mode GT Mode NAV Mode

1° · -3° · GT Mode

Page 14 of the Furuno CI-80 user manual — Features
Page 14 · click to enlarge
Page 14

Features

The CI-80 mainly consists of three units: a display unit, a transceiver unit, and a transducer, each compact enough to fit on small boats.

The main features of the CI-80 are;

  • Even in deep waters where ground (bottom) reference is not available acoustically, the CI-80 can provide absolute movements of measuring layers by receiving position (or speed) data from GPS navigator and heading data from gyro compass. It may be used on deep sea fishing boats or on ocean research vessels.
  • Triple-beam system for automatic compensation against pitching and rolling of vessel.
  • Single mold transducer for excellent mechanical beaming accuracy.
  • DC powered for economic operation.
  • Alphanumeric information display on high resolution 10 inch color CRT.
  • Simultaneous display of tide vectors and ship’s track. Indispensable for maneuvering and docking.
  • Echo level display constantly displays underwater conditions of three sounding beams.
  • Target point feature predicts flow of objects (for example, fishing tackle) against tide.
  • Easy-to-follow menu operation for control of various settings and measuring conditions.
Page 15 of the Furuno CI-80 user manual — Transceiver unit (CI-810)
Page 15 · click to enlarge
Page 15

SYSTEM OVERVIEW

Control Description

Display unit (CI-800)

Furuno CI-80 — Display unit (CI-800) diagram (page 15)
Fig. 6 · Display unit (CI-800)

Figure 11 Display unit

Transceiver unit (CI-810)

Furuno CI-80 — Transceiver unit (CI-810) diagram (page 15)
Fig. 7 · Transceiver unit (CI-810)

Figure 12 Transceiver unit

Page 16 of the Furuno CI-80 user manual — TARGET
Page 16 · click to enlarge
Page 16

Table 1 Control description

ON

Turns the system on/off.

OFF

Adjusts brilliance of display. Setting can be locked by pushing in control.

0 BRLL

Alternately selects echo display and course plot display.

DISP MODE

Selects tracking mode among ground tracking, water tracking, nav aided and automatic selection.

MODE

(G) (W) (A)

Select "T/D" or "NAV" from the item WATER SPEED on the SYSTEM menu.

(G) (N) (A)

Opens/closes the menu.

MENU

Select menu.

In menu operation, select menu items; change settings; enter data. On the course plot display, shift cursor.

Turns cursor on/off.

CURSOR

ON/OFF

Enters event mark. Also activates self tests and demonstration display and register calibrations.

EVENT

Calculates trip distance. Also enables system menu, when pressed and held down while pressing the MENU key.

TRIP

Inscribes target point mark, to predict flow of object (for example, fishing tackle) against tide.

TARGET

POINT

Control Description

Page 17 of the Furuno CI-80 user manual — Echo display
Page 17 · click to enlarge
Page 17

How to Read the Displays

The CI-80 has two display modes: echo display and course plot display.

A display may be selected with the DISP MODE key.

Echo display

Furuno CI-80 — Echo display diagram (page 17)
Fig. 8 · Echo display

Figure 13 Sample echo display

Page 18 of the Furuno CI-80 user manual — Course plot display
Page 18 · click to enlarge
Page 18

When speed or depth data appears in red…

Speed or depth data containing error appears in red.

Ships speed Cannot find reference echo in respective tracking mode.

Tide speed Cannot find echo in given layer.

Set depth Depth set is invalid. In ground tracking mode, depth should be shallower than 7 m, or in the water tracking mode no more 3/4 of seabed depth.

Measured speed When measured speed (tide or ship's) is unreliable.

Course plot display

Furuno CI-80 — Course plot display diagram (page 18)
Fig. 9 · Course plot display

Figure 14 Sample course plot display

with display mode as follows, by a DIP switch in the display unit.

Page 19 of the Furuno CI-80 user manual — How to Read the Displays
Page 19 · click to enlarge
Page 19
Furuno CI-80 — How to Read the Displays diagram (page 19)
Fig. 10 · How to Read the Displays

three seconds, in the default setting. They can be updated every second. For details, consult your dealer.

Page 20 of the Furuno CI-80 user manual — DEP Menu
Page 20 · click to enlarge
Page 20

MAIN MENU DESCRIPTION

Most major functions of the CI-80 are carried out through an easy-to-follow menu system. The menu system consists of two main groups of menus: main (operation) and system (testing, calibration). This chapter covers the main menu. For complete menu tree, see page 36.

Basic Menu Operation

Most major functions of the CI-80 are carried out through an easy-to-follow menu system.

Two general types of menus are used: main (operation) and system (testing).

Opening/closing the menu: Press the MENU key.

Selecting menus: Press ◄ / ►.

Selecting menu items: Press / .

Selecting menu options, changing settings: Press / .

DEP Menu

Furuno CI-80 — DEP Menu diagram (page 20)
Fig. 11 · DEP Menu

This menu sets both the measuring depths for three layers and the reference layer for tide differential calculation.

LAYER 1, LAYER 2, LAYER 3: Depth for measuring layers 1, 2 and 3 can be set between 2 and 250 meters, in resolution of one meter.

REF TIDE DIFFERENCE: Selects tide layer to be used reference layer in tide differential calculation.

number does not necessarily correspond to depth in ascending order.

Figure 15 DEP menu

Page 21 of the Furuno CI-80 user manual — TRK Menu
Page 21 · click to enlarge
Page 21

ECHO Menu

Furuno CI-80 — ECHO Menu diagram (page 21)
Fig. 12 · ECHO Menu

Sets up the echo display.

SPEED RANGE: Sets length of tide speed vector between 0.1 and 15.0 knots, in resolution of 0.1 knots.

ECHO DEPTH RANGE: Sets echo depth range. Depth can be set either manually between 50 and 300 meters in resolution of 50 meters or automatically. In AUTO, seabed depth is automatically selected as depth range.

ECHO LEVEL SHIFT: Sets echo intensity level, between 1 and 100 in resolution of 1. The higher the figure the stronger the echo level.

does not affect detection of tide speed or ship’s speed.

Figure 16 ECHO menu

TRK Menu

Furuno CI-80 — TRK Menu diagram (page 21)
Fig. 13 · TRK Menu

Sets up the course plot display.

PLOT RANGE: Sets latitude and longitude range of course plot, between 0.1 and 5.0 miles in resolution of 0.1 mile.

PLOT MODE: You may select either Head-up (bow at top of display) or North-up (North at top of display) orientation.

TRACK DISPLAY: Turn on/off trackline display.

Figure 17 TRK menu

Page 22 of the Furuno CI-80 user manual — AVR Menu
Page 22 · click to enlarge
Page 22

MARK Menu

Furuno CI-80 — MARK Menu diagram (page 22)
Fig. 14 · MARK Menu

This menu sets measuring conditions for tide vector and target point mark.

PRESET REFERENCE VALUE: Sets the effect of tide on the target point mark. The higher the figure, the greater the effect of tide.

TIDE HISTORY: Sets tide vector plotting interval, among 0 (turns off tide vector display), 15 sec. (1/4 min.), 1 min., 5 min., 10 min., 30 min., and 60 min.

Figure 18 MARK menu

AVR Menu

The AVR (Averaging) sets averaging time for measuring raw speed, tide and water tracking data, to smooth out random variation of data.

Furuno CI-80 — AVR Menu diagram (page 22)
Fig. 15 · AVR Menu

SHIP SPD AVR: Raw speed data (from connected sensor) may change randomly due to receiving conditions, etc. If speed data varies greatly increase speed averaging. Speed averaging is available in times of 15 sec., 30 sec., 60 sec., and 90 sec. The default setting is 15 sec., which is suitable for most conditions.

TIDE AVERAGE: Direction and speed of a tide changes with time, place and depth. Therefore it is important that the current indicator not respond to quickly or too slowly to tide movement. Tide averaging time is available between 0 and 5 minutes in the nearest minute. (“0” is for use of raw tide data.) In most cases “2 min.” provides excellent results. Too high a setting may prevent detection of rapid changes in tide movement, such as a current rip.

Figure 19 AVR menu

WT SPD DEPTH: Sets measuring depth of water speed in the water tracking mode. The default setting is two meters, and it is suitable for most conditions. Change the setting when water tracking speed display becomes unstable (due to air bubbles, etc.), or to measure water tracking speed at a given depth.

Page 23 of the Furuno CI-80 user manual — Selecting operating mode
Page 23 · click to enlarge
Page 23

OPERATION

Basic Operating Procedure

Turning on the system

1. Turn on the transceiver unit.
2. Turn on the display unit.
3. Adjust brilliance of display.

The display unit conducts a check of the system, displaying the results about 40 seconds after turning on the power.

Furuno CI-80 — Turning on the system diagram (page 23)
Fig. 16 · Turning on the system

Figure 20 Display unit and transceiver unit

Selecting operating mode

Press the MODE key to select operating mode among water tracking, ground tracking, or automatic selection. Selected mode appears at top right corner on the display.

Furuno CI-80 — Selecting operating mode diagram (page 23)
Fig. 17 · Selecting operating mode

N: Nav

Figure 21 Location of operating mode indication on echo

display

Page 24 of the Furuno CI-80 user manual — Setting measuring depths
Page 24 · click to enlarge
Page 24
„ Ground Tracking ModeShows absolute ship and tide

movements based on ground. (Bottom echo required.)

„ Water Tracking ModeShows movements of ship and tide

relative to near-surface water.

„ Nav-aided ModeShows ship’s movement measured by the

external navigation equipment, and the tide movements based on the nav speed data.

„ Auto Tracking ModeUses ground tracking mode when

bottom echo is available. Switches to water tracking mode (or nav-aided mode) when bottom echo is lost. Bottom echo is continuously searched for, and if re-acquired the ground tracking mode is restored.

Setting measuring depths

1. Press the MENU key.
2. Press ◄ / ► to select DEP menu.
3. Press / to select layer.
4. Press / to set depth.
5. Repeat steps 1-4 to set other layers.
Page 25 of the Furuno CI-80 user manual — Turning off the power
Page 25 · click to enlarge
Page 25

Setting tide differential layer

1. On the DEP menu, press / to select REF TIDE DIFFERENCE.
2. Press / to set layer.
Furuno CI-80 — Setting tide differential layer diagram (page 25)
Fig. 18 · Setting tide differential layer

Figure 22 How to set tide differential

Turning off the power

Press the power switch on the display unit.

Page 26 of the Furuno CI-80 user manual — Selecting a layer, setting depth
Page 26 · click to enlarge
Page 26

Setting Tide Measuring Depths on the Echo Display

Earlier you learned how to set tide measuring depths on the DEP menu.

Measuring depths can also be set directly on the echo display.

Selecting a layer, setting depth

1. On the echo display, press / to select layer desired. Selected layer’s depth indication changes from white to orange.
Furuno CI-80 — Selecting a layer, setting depth diagram (page 26)
Fig. 19 · Selecting a layer, setting depth

Figure 23 Echo display

2. Press / to set depth. “DEPTH SETTING” appears while setting depth.
3. Press to finish. Depth indications change from orange to white.
Page 27 of the Furuno CI-80 user manual — Registering settings, closing the menu
Page 27 · click to enlarge
Page 27

Setting up the Echo Display

Setting tide speed vector range

1. Press the MENU key.
Furuno CI-80 — Setting tide speed vector range diagram (page 27)
Fig. 20 · Setting tide speed vector range
2. Press ◄ / ► to select the

ECHO menu.

3. Press / to select SPEED RANGE.
4. Press / to set speed. (Default setting: 1.0 knot)

Figure 24 ECHO menu

Setting echo depth range

1. Press / to select ECHO DEPTH RANGE.
2. Press / to set depth. (Default setting: 100 meters)

Setting echo intensity

1. Press / to select ECHO LEVEL SHIFT.
2. Press / to set echo intensity.

Registering settings, closing the menu

Press the MENU key.

Page 28 of the Furuno CI-80 user manual — Setting tide vector plotting interval
Page 28 · click to enlarge
Page 28

Setting up the Course Plot Display

The course plot display mainly plots ship’s track. It can be displayed by pressing the DISP MODE key.

Furuno CI-80 — Setting up the Course Plot Display diagram (page 28)
Fig. 21 · Setting up the Course Plot Display

Figure 25 Sample course plot display, TRK menu

Setting the plot range

1. Press the MENU key.
2. Press ◄ / ► to select the TRK menu.
3. Press / to select PLOT RANGE.
4. Press / to set plot range.

Setting plot orientation

1. Press / to PLOT MODE.
2. Press / to select HU (Head-up) or NU (North-up).
Furuno CI-80 — Setting plot orientation diagram (page 28)
Fig. 22 · Setting plot orientation

Setting tide vector plotting interval

1. Press ◄ / ► to select the

MARK menu.

2. Press / to select TIDE HISTORY.
3. Press / to set plotting interval.

Figure 26 MARK menu

Page 29 of the Furuno CI-80 user manual — Target point mark
Page 29 · click to enlarge
Page 29

Marks

The CI-80 has two types of marks which can be inscribed on the display: event mark and target point mark.

Furuno CI-80 — Marks diagram (page 29)
Fig. 23 · Marks

Figure 27 Appearance of event mark and target point mark

Event mark

The EVENT key inscribes present position on the display. It is useful for marking important locations, etc. 25 event marks may be entered. When the event mark memory is full the oldest event mark is erased to make room for the latest.

Target point mark

The TARGET POINT key inscribes a target point mark on the display. The target point mark is useful for estimating 3-D deformation of fishing tackle (net, etc.) by the effect of tides at different depths. 25 target point marks can be entered. When the target point mark memory is full the oldest target point mark is erased to make room for the latest.

Tide effect can be set on the MARK menu.

Page 30 of the Furuno CI-80 user manual — Opening the system menu
Page 30 · click to enlarge
Page 30

Erasing marks

1. Press the CURSOR ON/OFF key.
Furuno CI-80 — Erasing marks diagram (page 30)
Fig. 24 · Erasing marks
2. Operate the four arrow keys to place cursor on mark to erase.
3. Press the EVENT key (or TARGET POINT key).

Figure 28 How to erase

Calculating Trip Distance

Press the TRIP key to start calculation of trip distance from present position. The trip distance indication is automatically reset to zero.

Furuno CI-80 — Calculating Trip Distance diagram (page 30)
Fig. 25 · Calculating Trip Distance

Figure 29 Course plot display, showing location of trip distance

Calibrations (offsets)

Offsets can be applied to measured values to further refine accuracy. This can be done on the CALB menu.

Opening the system menu

1. Press the DISP MODE key to display the echo display.
2. While pressing and holding down the TRIP key, press the MENU key.

marks · indication

Page 31 of the Furuno CI-80 user manual — Water Speed Display Setting
Page 31 · click to enlarge
Page 31

Displaying the CALB menu

1. Press ◄ / ► to select the CALB menu.

MODE CALB

2. Press / to select menu item.

GT SPD CALIB

3. Press / to set offset.

0.0 % [-12.8~12.7]

WT SPD CALIB

Menu items

0.0 % [-12.8~12.7]

GT SPD CALIB: Raise setting when ground tracking speed is slower than ship’s speed.

DRAFT LEVEL

0.0 m [0.0~50.0]

WT SPD CALIB: Raise setting when water tracking speed is slower than ship’s speed.

BEARING CALIB

0.0 ° [-12.8~12.7]

DRAFT LEVEL: Enter depth of transducer from sea surface.

COURSE CALIB

0.0 ° [-12.8~12.7]

BEARING CALIBCompensate for bearing error in

relation to ship’s bow.

*1: Shown when current (tide) processor is active.

COURSE CALIB: Compensate for course error.

from that of navigator (GPS) even with a correct bearing calibration, enter the course calibration angle.

Figure 30 CALB menu

4. Press the MENU key to register settings and close the menu.

Water Speed Display Setting

1. Press the DISP MODE key to display the echo display.
2. While pressing and holding down the TRIP key press the MENU key.
3. Press ◄ / ► to select MODE.
4. Press or to select WATER SPEED.
5. Press or to select T/D or NAV.

T/D: Ship’s speed, tide and tide differential are calculated from doppler shift frequency. Press the MODE key to select measuring mode, in the sequence of G(Ground), W(Water), A(Auto).

NAV: Ship’s speed and position data are fed from the GPS navigator. Tide and tide differential are calculated using GPS data when the ground echo cannot be detected. Press the MODE key to select measuring mode, in the sequence of G(Ground), N(Nav), A(Auto).

*1

Page 32 of the Furuno CI-80 user manual — Nav Data Setting
Page 32 · click to enlarge
Page 32

MODE CALB

SELF TEST

OFF SYS

ECHO PNL

DEMONSTRATION

OFF ON

WATER SPEED

T/D NAV

NAV DATA

SPD L/L

*1: Shown when tide processor is active.

Figure 31 MODE menu

Nav Data Setting

1. Press the DISP MODE key to display the echo display.
2. While pressing and holding down the TRIP key press the MENU key.
3. Press ◄ / ► to select MODE.
4. Press or to select NAV DATA.
5. Press or to select L/L or SPD.

“L/L”: Calculates speed internally from position data change.

“SPD”: Takes speed data from external navigator as they are. (Select “SPD” if connected with GPS.)

*1 · *1

Page 33 of the Furuno CI-80 user manual — Transducer unit
Page 33 · click to enlarge
Page 33

MAINTENANCE & TROUBLESHOOTING

Preventive Maintenance

Regular checks

  • Regular maintenance is important for continued performance. Check the following on a monthly basis.
  • Check that all connectors and cables are securely tightened.
  • Check grounding systems of units for corrosion.
  • Also regularly measure voltage to confirm that it is within prescribed rating.

Cleaning of units

Display unit/ transceiver unit

Accumulated dirt can be wiped off with a soft cloth. If necessary, a mild detergent diluted in water may be used. Chemical cleaners should not be used to clean any unit; they can remove paint and markings.

Transducer unit

Barnacles and other marine life adhering to the transducer face can cause a considerable drop in performance. Check the transducer face regularly for marine life and clean if necessary. The transducer should never be painted.

Page 34 of the Furuno CI-80 user manual — Troubleshooting
Page 34 · click to enlarge
Page 34

Troubleshooting

The troubleshooting table which follows provides simple troubleshooting procedures which the user may use to restore normal operation. If normal operation cannot be restored, do not attempt to check inside any unit. Any repair is best left to a qualified technician.

Table 2 Troubleshooting table

power is on but nothing appears on the display

  • adjust BRILL control.
  • check power cable.
  • check for loosened power connector.
  • check for blown fuse.

nothing appears on the echo display

  • check that transceiver unit is turned on.
  • check power cable and connector on transceiver unit for tight connection.
  • check fuse on transceiver unit.

echo display is normal but echo or tide is not displayed

  • check interconnection cable between transceiver unit and display unit.
  • adjust BRILL control.

color is distorted or display is too bright/ dark

  • check for magnets near display unit.

certain colors are abnormal or picture jumps

  • try turning off and on the power to restore normal picture.

tide vector is not displayed

  • “TIDE HISTORY” on the MARK menu may be set to “0”.

no echoes are displayed

  • “ECHO LEVEL SHIFT” on the ECHO menu may be set too narrow.
  • “TRACK DISPLAY” on the TRK menu may be turned off.

If ship’s track is not displayed

seabed does not appear on the echo display

  • “ECHO DEPTH RANGE” on the ECHO menu is set too shallow. Set to suitable depth, or select AUTO.
  • depth is beyond measurable depth (300 meters).

echo display is interrupted

  • vessel is in heavy seas or passing over wake of another vessel.
  • marine life may be adhering to the transducer.

tide data is unstable • “TIDE AVERAGE” on the AVR menu may be set to “0”.

interference is present on the display

  • check ground for corrosion.
  • cables of other equipment may be too near transducer cable.

If… Then…

Page 35 of the Furuno CI-80 user manual — SPD L/L
Page 35 · click to enlarge
Page 35

Self Tests, Demonstration Display

The CI-80 has four self tests and a demonstration display which check the system for proper operation.

Display the system menu

1. Press the DISP MODE key to select the echo display.
2. While pressing and holding down the TRIP key, press the MENU key.

Conducting self tests

1. Press ◄ / ► to select the MODE menu.

MODE CALB

SELF TEST

2. Press / to select SELF TEST

OFF SYS

ECHO PNL

3. Press / to select test.

DEMONSTRATION

Self test menu description

OFF ON

WATER SPEED

SYS: Conducts general check of all circuit boards.

T/D NAV

ECHO: Checks receiver and transmitter.

NAV DATA

PNL: Checks key and switches of display unit.

SPD L/L

4. Press the EVENT key to start test.
5. Press the MENU key when test is completed.

*1: Shown when tide processor is active.

To quit the self test, Select “SELF TEST-OFF” on the MODE menu and press the EVENT key.

Figure 32 MODE menu

*1 · *1

Page 36 of the Furuno CI-80 user manual — NAV DATA *1
Page 36 · click to enlarge
Page 36

Starting the demonstration display

MODE CALB

The demonstration display checks the controls on the display unit and conducts a loopback test between the display unit and the transceiver unit.

SELF TEST

OFF SYS

ECHO PNL

DEMONSTRATION

1. Press / to select DEMONSTRATION.

OFF ON

2. Press to select ON.

WATER SPEED

3. Press the EVENT key.

T/D NAV

The echo display appears and the demonstration begins. "DEMO DATA OUTPUTTING” appears while the demonstration display is on. All data shown is for purpose of demonstration; it is not actual data.

NAV DATA *1

SPD L/L

To quit the demonstration display, select “DEMONSTRATION- OFF” on the MODE menu and press the EVENT key.

*1: Shown when tide processor is active.

Figure 33 MODE menu

*1

Page 37 of the Furuno CI-80 user manual — ---------CI-810---------
Page 37 · click to enlarge
Page 37

Self Test Results

System test

The system test check results appear at each power on or whenever the system check is conducted though the self test.

SYSTEM CHECK

---------CI-800---------

IP VOL 66503001** ICP Board ROM prog. no. IP DSW “00 00” IPU Board’s DIP switch setting in hexadecimal notation IP MEM 1 2 3 4 5 6 OK ICP Board memory test IP MEM 7 8 9

CI-810

CP VOL 66503101** JCPA Board ROM prog no. CP VOL 66503110** CP MEM 1 2 3 4 5 6 7 8 OK JCPA Board memory test CP DSW “00” JCPA Board’s DIP switch setting in hexadecimal notation FT VOL 66503201** JFTA Board ROM prog. no. FT NEM 1 2 3 4 5 6 7 OK JFTA Board memory test. TX DEV 1 OK TX device test. IF VOL 66500401** JIFA Board ROM prog no. IF MEM 1 2 3 JIFA Board memory test IF DSW “00 00 00” JIFA Board’s DIP switch setting in hexadecimal notation IF DEV 1 JIFA Board device test IF AN1 RU3 00V RL2.00V OK

AD Converter reference voltage test IF AN2 MLD 2.50V Temperature sensor signal test IF AN3 PWR 1.01V Power check IF AN4 PTH…RLL…V Inclinometer signal test IF AN5 IS1 1.01V IS2 1.01V ERR No. Error Number NOTE: **indicates version no.

Test ICP JCPA JFTA JIFA

Prog. ROM test 5 6 1 1

Data ROM test 6

Memory test 1-4, 7-9 1-5, 7-8 2-7 2-3

Page 38 of the Furuno CI-80 user manual — Error display
Page 38 · click to enlarge
Page 38

Error display

“OK” appears for normal memory IC test. For fault NG (No Good) and asterisk (*) appear next to ROM/RAM number.

Table 3 Error number display and meaning

Furuno CI-80 — Error display diagram (page 38)
Fig. 26 · Error display

200 External KP input interval JCPA, JIFA, abnormal external KP interval

201 Depth sensor input JLGA, JCPA, JIFA, faulty temperature sensor

202 Inclinometer roll signal JCPA, JIFA, no inclinometer data

203 Inclinometer pitch signal JCPA, JIFA, no inclinometer data

* Abnormally high Tx voltage, abnormally low transducer impedance, too high Tx duty, faulty temperature sensor (faulty element), high water temperature, and other factors may also cause this error display.

Page 39 of the Furuno CI-80 user manual — Panel test
Page 39 · click to enlarge
Page 39

Echo test

Checking echo display intensity

Press the right and left arrow keys. The SHIFT indication should change with key operation, between 0 and 100.

Checking echo display range

Press the up and down arrow keys. The echo display range should in steps of 50 between 0 and 300.

Furuno CI-80 — Checking echo display range diagram (page 39)
Fig. 27 · Checking echo display range

Figure 34 Sample echo test display

Panel test

Press each key on the control panel one by one. The pressed key’s corresponding “0” on the display should change to “1”.

Furuno CI-80 — Panel test diagram (page 39)
Fig. 28 · Panel test

Figure 35 Panel test display

Page 40 of the Furuno CI-80 user manual — DEMONSTRATION OFF ON
Page 40 · click to enlarge
Page 40

MENU TREE

MAIN MENU DEP LAYER1 LAYER2 LAYER3 REF TIDE DIFFERENCE

ECHO SPEED RANGE ECHO DEPTH RANGE ECHO LEVEL SHIFT

TRK PLOT RANGE PLOT MODE TRACK DISPLAY

MARK PRESET REFERENCE VALUE TIDE HISTORY

AVR SHIP SPD AVR TIDE AVERAGE WT SPD DEPTH

SYSTEM MENU MODE SELF TEST OFF SYS ECHO PANEL

DEMONSTRATION OFF ON

WATER SPEED T/D NAV

NAV DATA SPD L/L

CALIB GT SPD CALIB WT SPD CALIB DRAFT LEVEL BEARING CALIB COURSE CALIB

Page 41 of the Furuno CI-80 user manual — SP-1
Page 41 · click to enlarge
Page 41

SPECIFICATIONS OF CI-80 DOPPLER SONAR CURRENT INDICATOR

1. General (1) Ground tracking acquirable 3m-200m (measure able range 300m) depth (2) Measurable tide range 2m-100m, or 75% of depth, whichever is shallower (3) Measurable tide depth 10m (measurable from 7m) (4) Measurable ship's speed Fore/aft: +30kts to –10kts, Port/starboard: +9.9kts to –9.9kts (5) Measurable tide speed 0kts to 9.9kts (6) Tide differential range –9.9kts to +9.9kts (7) Measuring accuracy Ship’s speed: ±1 (1% +0.1kt), Tide speed: (±2% +0.1kt) (8) Number of beams Three (tilt angle 60° each beam) (9) Transmitting frequency 288kHz (10) Display type 10-inch color CRT 2. Display (1) Common displays Speed, heading: 360 degree or 32 compass points Tide speed, direction: Three layers (2) Course plot display Track display: DR, max. 1000 pts. Tide vector: Three layers, max. 1000 pts. Target point mark: 25 pts. Event mark: 25 pts. Ship’s position: Latitude, longitude Orientation: Head-up (true motion), North-up Trip distance indication: Provided (3) Echo display Tide vector: Three layers, circular graph Tide differential: Three layers, measurement between two layers Video sounder: Three directions (4) Other Self test: All circuit boards, controls demonstration: With internal data Calibration facilities Range selection Object flow prediction 3. Input/Output Signal (1) Input signal Compass signal (heading): AD-100 format KP (2 circuits): Photo isolation (current loop) CIF/NMEA 0183: Position data (2) Output signal Log signal: 200/400 pulses, contact signal KP signal: TTL CIF/NMEA 0183: Speed, tide CI-7000 format signal 4. Environmental Conditions (1) Useable temperature 0°C to 45°C (2) Relative humidity 85% 5. Power Supply & Power Consumption Main’s input 11-40VDC, less than 120W avg., or 100/110/115/220/230VAC, 1φ, 50/60Hz (rectifier required)

SP-1

Ask about the Furuno CI-80

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Furuno CI-80

Be the first to ask — other owners or our team will answer.

Original document

Furuno CI-80 manual PDF

41 pages·768 KB·Radar Detector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…