Your Loc al A gent/Deal er
All rights reserved.
PUB. No. OME-72390 CI- 80 (DAMI)


WARNING
WARNING
Keep heater away from equipment.
ELECTRICAL SHOCK HAZARD Do not open the equipment.
A heater can melt the equipment’s power cord, which can cause fire or electrical shock.
Only qualified personnel should work inside the equipment.
Use the proper fuse.
Immediately turn off the power at the switchboard if water leaks into the equipment or something is dropped in the equipment.
Fuse rating is shown on the equipment. Use of a wrong fuse can result in equip- ment damage.
Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO agent for service.
Do not operate the equipment with wet hands.
Electrical shock can result.
Do not disassemble or modify the equipment.
Fire, electrical shock or serious injury can result.
Do not place liquid-filled containers on the top of the equipment.
A warning label is attached to the equipment. Do not remove the label. If the label is missing or damaged, contact a FURUNO agent or dealer.
Fire or electrical shock can result if a liquid spills into the equipment.
Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire.
Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO agent for service.
Make sure no rain or water splash leaks into the equipment.
Fire or electrical shock can result if water leaks in the equipment.


PRINCIPLE OF MEASUREMENT, FEATURES
When a moving vessel emits an acoustical pulse into the water at an angle, a portion of emitted energy is reflected from the seabed and other microscopic objects in the sound path, such as plankton or air bubbles. The frequency of the received signal is shifted from the transmitted frequency in proportion to relative velocity between the vessel and underwater reflecting objects. This is called Doppler Effect.
The CI-80 calculates and displays movements of ship and currents at specific depths by measuring Doppler shifts obtained from three separate directions.
Frequency of reflected signal is shifted in proportion to relative speed between the vessel and reflecting objects.
Depending on the base of measurement, ship’s speed is expressed in two ways:
Water tracking speed: Ship’s speed and course relative to (Relative speed) water layer just below the vessel (floating base)
Planktonic layer · Seabed

Nav-aided speed (Pseudo ground tracking speed)
:Base of measurement
Tide is movement of watermass at a particular depth.
To know absolute tide (speed on ground), the following two data are required:
1 Ship’s speed and course based on ground
2 Ship’s speed and course based on measuring layer (A)
Absolute tide is, then, given as a difference of these two speed vectors.
Absolute Tide = 1 – 2
:Base of measurement

Nav-Tide is an absolute movement of watermass at a particular depth, taking speed information from the external navigator (GPS) as a pseudo ground tracking speed.
To calculate Nav-tide, the following two data are required:
1 Ship’s speed and course obtained by external navigation equipment (GPS)
2 Ship’s speed and course based on measuring layer (A)
Nav-tide is, then, given as a difference of these two speed vectors.
Absolute Tide = 1 – 2
Nav-aided speed (Pseudo ground tracking speed)
:Base of measurement
Tide differential is a relative movement of tides at different depths, layer (A) and layer (B).
To calculate tide differential, the following two data are used:
1 Ship’s speed and course based on layer (A)
2 Ship’s speed and course based on layer (B)
Tide differential between two layers is, then, given as a difference of these two speed vectors.
GPS satellites · Water tracking speed · Layer (A)

Tide Difference = 1 - 2 (Movement of layer B based on
= 2 - 1 (Movement of layer A based on
Layer (B) :Base of measurement
Absolute tide can be measured in the ground tracking mode.
10 NM (1 hour trip)
(Moving at 10 kt on ground)
(Moving at 3 kt on ground)
:Base of measurement
Assume that the ship and layer A are moving in the same direction, and ship’s speeds based on ground (Vg) and on layer A (Vwa) are measured as;
Vg = 10 kt (Ship’s speed based on ground)
Vwa = 7 kt (Ship’s speed based on layer A).

Speed of layer A based on ground (C1) can be calculated as follows:
C1 = Vg – Vwa
= 10 – 7
Absolute tide can be measured in the nav-aided mode.
Nav-aided ship’s speed (Vn) is equivalent to ship’s ground tracking speed in the ideal conditions. That is, the nav-tide can be calculated by simply replacing Vg with Vn in the above equation.
Tide differential is a relative movement of tides at different depths.
It can be measured in the ground tracking, water tracking and nav-aided modes.
10 NM (1 hour trip)
:Base of measurement

Assuming that the ship, layer A and layer B are moving in the same direction, and ship’s speeds based on layer A (Vwa) and on layer B (Vwb) are measured as;
Vwa = 8 kt (Ship’s speed based on layer A)
Vwb = 5 kt (Ship’s speed based on layer B)
As an absolute ship’s speed (Vg) is available in the ground tracking mode, tide speeds of layer A (C1) and layer B (C2) based on ground are calculated as follows:
C1 = Vg - Vwa (Speed of layer A based on ground)
C2 = Vg - Vwb (Speed of layer B based on ground)
Thus, the tide differential (Cd) between layer A and layer B is;
Cd = C2 - C1 = (Vg - Vwb) - (Vg - Vwa) = Vwa - Vwb = 8 - 5 = 3 (kt)
Tide differential based on layer A
Speed of layer B viewed from layer A
Cd = C1 - C2 = (Vg - Vwa) - (Vg - Vwb) = Vwb - Vwa = 5 - 8 = -3 (kt)
Tide differential based on layer B
Speed of layer A viewed from layer B
In the water tracking mode, watermass just below the transducer (near-surface layer) is taken as the base of all measurements (virtual ground). Therefore, the ship and tide speeds in the water tracking mode are not absolute but relative to this near-surface layer.
Vw = 9 kt (Ship’s speed based on near-surface layer)
Vwa = 8 kt (Ship’s speed based on layer A)
Vwb = 5 kt (Ship’s speed based on layer B)
or

10 NM (1 hour trip)
:Base of measurement Layer A
1 kt Assume that the ship and all measuring layers are moving in the same direction, but at different speeds.

IMPORTANT NOTICE ON TIDE MEASUREMENTS
(In the nav-aided mode, tide accuracy depends heavily on gyro accuracy.)
The CI-80 has the nav-aided mode to measure absolute tides even in deep waters where ground tracking is unattainable. To achieve reliable measurements, however, you must supply accurate heading (gyro) information and ship’s position (or speed/course) data to the CI-80.
If you are going to use the nav-aided mode, set the reading of the AD converter (gyro interface) exactly with that of the master gyrocompass.

AD Converter (Gyro Interface)
If the gyro reading is accurate, the CI-80 should provide accurate tide information. If the gyro data contains some error, however, you may see the following symptoms.
Procedure · Master Gyrocompass

0 10 20 10 20
0 10 20 10 20
0.2 kt
0.5 kt
NAV Mode GT Mode NAV Mode
1° · -3° · GT Mode

The CI-80 mainly consists of three units: a display unit, a transceiver unit, and a transducer, each compact enough to fit on small boats.
The main features of the CI-80 are;

Control Description

Figure 11 Display unit

Figure 12 Transceiver unit

Table 1 Control description
Turns the system on/off.
Adjusts brilliance of display. Setting can be locked by pushing in control.
Alternately selects echo display and course plot display.
Selects tracking mode among ground tracking, water tracking, nav aided and automatic selection.
(G) (W) (A)
Select "T/D" or "NAV" from the item WATER SPEED on the SYSTEM menu.
Opens/closes the menu.
Select menu.
In menu operation, select menu items; change settings; enter data. On the course plot display, shift cursor.
Turns cursor on/off.
ON/OFF
Enters event mark. Also activates self tests and demonstration display and register calibrations.
Calculates trip distance. Also enables system menu, when pressed and held down while pressing the MENU key.
Inscribes target point mark, to predict flow of object (for example, fishing tackle) against tide.
POINT
Control Description

The CI-80 has two display modes: echo display and course plot display.
A display may be selected with the DISP MODE key.

Figure 13 Sample echo display

Speed or depth data containing error appears in red.
Ships speed Cannot find reference echo in respective tracking mode.
Tide speed Cannot find echo in given layer.
Set depth Depth set is invalid. In ground tracking mode, depth should be shallower than 7 m, or in the water tracking mode no more 3/4 of seabed depth.
Measured speed When measured speed (tide or ship's) is unreliable.

Figure 14 Sample course plot display
with display mode as follows, by a DIP switch in the display unit.


three seconds, in the default setting. They can be updated every second. For details, consult your dealer.

Most major functions of the CI-80 are carried out through an easy-to-follow menu system. The menu system consists of two main groups of menus: main (operation) and system (testing, calibration). This chapter covers the main menu. For complete menu tree, see page 36.
Most major functions of the CI-80 are carried out through an easy-to-follow menu system.
Two general types of menus are used: main (operation) and system (testing).
Opening/closing the menu: Press the MENU key.
Selecting menus: Press ◄ / ►.
Selecting menu items: Press / .
Selecting menu options, changing settings: Press / .

This menu sets both the measuring depths for three layers and the reference layer for tide differential calculation.
LAYER 1, LAYER 2, LAYER 3: Depth for measuring layers 1, 2 and 3 can be set between 2 and 250 meters, in resolution of one meter.
REF TIDE DIFFERENCE: Selects tide layer to be used reference layer in tide differential calculation.
number does not necessarily correspond to depth in ascending order.
Figure 15 DEP menu


Sets up the echo display.
SPEED RANGE: Sets length of tide speed vector between 0.1 and 15.0 knots, in resolution of 0.1 knots.
ECHO DEPTH RANGE: Sets echo depth range. Depth can be set either manually between 50 and 300 meters in resolution of 50 meters or automatically. In AUTO, seabed depth is automatically selected as depth range.
ECHO LEVEL SHIFT: Sets echo intensity level, between 1 and 100 in resolution of 1. The higher the figure the stronger the echo level.
does not affect detection of tide speed or ship’s speed.
Figure 16 ECHO menu

Sets up the course plot display.
PLOT RANGE: Sets latitude and longitude range of course plot, between 0.1 and 5.0 miles in resolution of 0.1 mile.
PLOT MODE: You may select either Head-up (bow at top of display) or North-up (North at top of display) orientation.
TRACK DISPLAY: Turn on/off trackline display.
Figure 17 TRK menu


This menu sets measuring conditions for tide vector and target point mark.
PRESET REFERENCE VALUE: Sets the effect of tide on the target point mark. The higher the figure, the greater the effect of tide.
TIDE HISTORY: Sets tide vector plotting interval, among 0 (turns off tide vector display), 15 sec. (1/4 min.), 1 min., 5 min., 10 min., 30 min., and 60 min.
Figure 18 MARK menu
The AVR (Averaging) sets averaging time for measuring raw speed, tide and water tracking data, to smooth out random variation of data.

SHIP SPD AVR: Raw speed data (from connected sensor) may change randomly due to receiving conditions, etc. If speed data varies greatly increase speed averaging. Speed averaging is available in times of 15 sec., 30 sec., 60 sec., and 90 sec. The default setting is 15 sec., which is suitable for most conditions.
TIDE AVERAGE: Direction and speed of a tide changes with time, place and depth. Therefore it is important that the current indicator not respond to quickly or too slowly to tide movement. Tide averaging time is available between 0 and 5 minutes in the nearest minute. (“0” is for use of raw tide data.) In most cases “2 min.” provides excellent results. Too high a setting may prevent detection of rapid changes in tide movement, such as a current rip.
Figure 19 AVR menu
WT SPD DEPTH: Sets measuring depth of water speed in the water tracking mode. The default setting is two meters, and it is suitable for most conditions. Change the setting when water tracking speed display becomes unstable (due to air bubbles, etc.), or to measure water tracking speed at a given depth.

Basic Operating Procedure
The display unit conducts a check of the system, displaying the results about 40 seconds after turning on the power.

Figure 20 Display unit and transceiver unit
Press the MODE key to select operating mode among water tracking, ground tracking, or automatic selection. Selected mode appears at top right corner on the display.

N: Nav
Figure 21 Location of operating mode indication on echo
display

movements based on ground. (Bottom echo required.)
relative to near-surface water.
external navigation equipment, and the tide movements based on the nav speed data.
bottom echo is available. Switches to water tracking mode (or nav-aided mode) when bottom echo is lost. Bottom echo is continuously searched for, and if re-acquired the ground tracking mode is restored.


Figure 22 How to set tide differential
Press the power switch on the display unit.

Earlier you learned how to set tide measuring depths on the DEP menu.
Measuring depths can also be set directly on the echo display.

Figure 23 Echo display


ECHO menu.
Figure 24 ECHO menu
Press the MENU key.

The course plot display mainly plots ship’s track. It can be displayed by pressing the DISP MODE key.

Figure 25 Sample course plot display, TRK menu

MARK menu.
Figure 26 MARK menu

The CI-80 has two types of marks which can be inscribed on the display: event mark and target point mark.

Figure 27 Appearance of event mark and target point mark
The EVENT key inscribes present position on the display. It is useful for marking important locations, etc. 25 event marks may be entered. When the event mark memory is full the oldest event mark is erased to make room for the latest.
The TARGET POINT key inscribes a target point mark on the display. The target point mark is useful for estimating 3-D deformation of fishing tackle (net, etc.) by the effect of tides at different depths. 25 target point marks can be entered. When the target point mark memory is full the oldest target point mark is erased to make room for the latest.
Tide effect can be set on the MARK menu.


Figure 28 How to erase
Press the TRIP key to start calculation of trip distance from present position. The trip distance indication is automatically reset to zero.

Figure 29 Course plot display, showing location of trip distance
Offsets can be applied to measured values to further refine accuracy. This can be done on the CALB menu.
marks · indication

0.0 % [-12.8~12.7]
Menu items
0.0 % [-12.8~12.7]
GT SPD CALIB: Raise setting when ground tracking speed is slower than ship’s speed.
0.0 m [0.0~50.0]
WT SPD CALIB: Raise setting when water tracking speed is slower than ship’s speed.
0.0 ° [-12.8~12.7]
DRAFT LEVEL: Enter depth of transducer from sea surface.
0.0 ° [-12.8~12.7]
relation to ship’s bow.
*1: Shown when current (tide) processor is active.
COURSE CALIB: Compensate for course error.
from that of navigator (GPS) even with a correct bearing calibration, enter the course calibration angle.
Figure 30 CALB menu
T/D: Ship’s speed, tide and tide differential are calculated from doppler shift frequency. Press the MODE key to select measuring mode, in the sequence of G(Ground), W(Water), A(Auto).
NAV: Ship’s speed and position data are fed from the GPS navigator. Tide and tide differential are calculated using GPS data when the ground echo cannot be detected. Press the MODE key to select measuring mode, in the sequence of G(Ground), N(Nav), A(Auto).
*1

SELF TEST
OFF SYS
ECHO PNL
DEMONSTRATION
OFF ON
WATER SPEED
T/D NAV
NAV DATA
SPD L/L
*1: Shown when tide processor is active.
Figure 31 MODE menu
“L/L”: Calculates speed internally from position data change.
“SPD”: Takes speed data from external navigator as they are. (Select “SPD” if connected with GPS.)
*1 · *1

Preventive Maintenance
Accumulated dirt can be wiped off with a soft cloth. If necessary, a mild detergent diluted in water may be used. Chemical cleaners should not be used to clean any unit; they can remove paint and markings.
Barnacles and other marine life adhering to the transducer face can cause a considerable drop in performance. Check the transducer face regularly for marine life and clean if necessary. The transducer should never be painted.

The troubleshooting table which follows provides simple troubleshooting procedures which the user may use to restore normal operation. If normal operation cannot be restored, do not attempt to check inside any unit. Any repair is best left to a qualified technician.
Table 2 Troubleshooting table
power is on but nothing appears on the display
nothing appears on the echo display
echo display is normal but echo or tide is not displayed
color is distorted or display is too bright/ dark
certain colors are abnormal or picture jumps
tide vector is not displayed
no echoes are displayed
If ship’s track is not displayed
seabed does not appear on the echo display
echo display is interrupted
tide data is unstable • “TIDE AVERAGE” on the AVR menu may be set to “0”.
interference is present on the display
If… Then…

The CI-80 has four self tests and a demonstration display which check the system for proper operation.
SELF TEST
ECHO PNL
Self test menu description
OFF ON
WATER SPEED
SYS: Conducts general check of all circuit boards.
ECHO: Checks receiver and transmitter.
PNL: Checks key and switches of display unit.
*1: Shown when tide processor is active.
To quit the self test, Select “SELF TEST-OFF” on the MODE menu and press the EVENT key.
Figure 32 MODE menu
*1 · *1

The demonstration display checks the controls on the display unit and conducts a loopback test between the display unit and the transceiver unit.
OFF SYS
ECHO PNL
DEMONSTRATION
The echo display appears and the demonstration begins. "DEMO DATA OUTPUTTING” appears while the demonstration display is on. All data shown is for purpose of demonstration; it is not actual data.
SPD L/L
To quit the demonstration display, select “DEMONSTRATION- OFF” on the MODE menu and press the EVENT key.
*1: Shown when tide processor is active.
Figure 33 MODE menu
*1

The system test check results appear at each power on or whenever the system check is conducted though the self test.
---------CI-800---------
IP VOL 66503001** ICP Board ROM prog. no. IP DSW “00 00” IPU Board’s DIP switch setting in hexadecimal notation IP MEM 1 2 3 4 5 6 OK ICP Board memory test IP MEM 7 8 9
CP VOL 66503101** JCPA Board ROM prog no. CP VOL 66503110** CP MEM 1 2 3 4 5 6 7 8 OK JCPA Board memory test CP DSW “00” JCPA Board’s DIP switch setting in hexadecimal notation FT VOL 66503201** JFTA Board ROM prog. no. FT NEM 1 2 3 4 5 6 7 OK JFTA Board memory test. TX DEV 1 OK TX device test. IF VOL 66500401** JIFA Board ROM prog no. IF MEM 1 2 3 JIFA Board memory test IF DSW “00 00 00” JIFA Board’s DIP switch setting in hexadecimal notation IF DEV 1 JIFA Board device test IF AN1 RU3 00V RL2.00V OK
AD Converter reference voltage test IF AN2 MLD 2.50V Temperature sensor signal test IF AN3 PWR 1.01V Power check IF AN4 PTH…RLL…V Inclinometer signal test IF AN5 IS1 1.01V IS2 1.01V ERR No. Error Number NOTE: **indicates version no.
Test ICP JCPA JFTA JIFA
Prog. ROM test 5 6 1 1
Data ROM test 6
Memory test 1-4, 7-9 1-5, 7-8 2-7 2-3

“OK” appears for normal memory IC test. For fault NG (No Good) and asterisk (*) appear next to ROM/RAM number.
Table 3 Error number display and meaning

200 External KP input interval JCPA, JIFA, abnormal external KP interval
201 Depth sensor input JLGA, JCPA, JIFA, faulty temperature sensor
202 Inclinometer roll signal JCPA, JIFA, no inclinometer data
203 Inclinometer pitch signal JCPA, JIFA, no inclinometer data
* Abnormally high Tx voltage, abnormally low transducer impedance, too high Tx duty, faulty temperature sensor (faulty element), high water temperature, and other factors may also cause this error display.

Press the right and left arrow keys. The SHIFT indication should change with key operation, between 0 and 100.
Press the up and down arrow keys. The echo display range should in steps of 50 between 0 and 300.

Figure 34 Sample echo test display
Press each key on the control panel one by one. The pressed key’s corresponding “0” on the display should change to “1”.

Figure 35 Panel test display

MAIN MENU DEP LAYER1 LAYER2 LAYER3 REF TIDE DIFFERENCE
ECHO SPEED RANGE ECHO DEPTH RANGE ECHO LEVEL SHIFT
MARK PRESET REFERENCE VALUE TIDE HISTORY
AVR SHIP SPD AVR TIDE AVERAGE WT SPD DEPTH
SYSTEM MENU MODE SELF TEST OFF SYS ECHO PANEL
WATER SPEED T/D NAV
NAV DATA SPD L/L
CALIB GT SPD CALIB WT SPD CALIB DRAFT LEVEL BEARING CALIB COURSE CALIB

1. General (1) Ground tracking acquirable 3m-200m (measure able range 300m) depth (2) Measurable tide range 2m-100m, or 75% of depth, whichever is shallower (3) Measurable tide depth 10m (measurable from 7m) (4) Measurable ship's speed Fore/aft: +30kts to –10kts, Port/starboard: +9.9kts to –9.9kts (5) Measurable tide speed 0kts to 9.9kts (6) Tide differential range –9.9kts to +9.9kts (7) Measuring accuracy Ship’s speed: ±1 (1% +0.1kt), Tide speed: (±2% +0.1kt) (8) Number of beams Three (tilt angle 60° each beam) (9) Transmitting frequency 288kHz (10) Display type 10-inch color CRT 2. Display (1) Common displays Speed, heading: 360 degree or 32 compass points Tide speed, direction: Three layers (2) Course plot display Track display: DR, max. 1000 pts. Tide vector: Three layers, max. 1000 pts. Target point mark: 25 pts. Event mark: 25 pts. Ship’s position: Latitude, longitude Orientation: Head-up (true motion), North-up Trip distance indication: Provided (3) Echo display Tide vector: Three layers, circular graph Tide differential: Three layers, measurement between two layers Video sounder: Three directions (4) Other Self test: All circuit boards, controls demonstration: With internal data Calibration facilities Range selection Object flow prediction 3. Input/Output Signal (1) Input signal Compass signal (heading): AD-100 format KP (2 circuits): Photo isolation (current loop) CIF/NMEA 0183: Position data (2) Output signal Log signal: 200/400 pulses, contact signal KP signal: TTL CIF/NMEA 0183: Speed, tide CI-7000 format signal 4. Environmental Conditions (1) Useable temperature 0°C to 45°C (2) Relative humidity 85% 5. Power Supply & Power Consumption Main’s input 11-40VDC, less than 120W avg., or 100/110/115/220/230VAC, 1φ, 50/60Hz (rectifier required)