User Guide KVM series2-1611 Keyboard/Video/Mouse Switch



English



Edition October 2005

The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs.
Fax forms for sending us your comments are included in the back of the manual.
There you will also find the addresses of the relevant User Documentation Department.
To ensure a consistently high quality standard and user-friendli ness, this documentation was created to meet the regulations of a quality management system which complies with the require ments of the standard DIN EN ISO 9001:2000.
Copyright © 2005 Fujitsu Siemens Computers GmbH.
All rights reserved. Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
This manual is printed on paper treated with chlorine-free bleach.









The Fujitsu Siemens KVM series2-1611 (KVM s2-1611) switches combine analog and digital technology to provide flexible, centralized control of data center serv ers. This solution delivers secure digital access and flexible server management from anywhere at any time.
Throughout the documentation you will see the word “appliance” used generically to describe the KVM s2-1611 switch.
The KVM s2-1611 consists of a rack mountable keyboard, video and mouse (KVM) switch configurable for analog or digital connectivity. Each KVM s2-1611 has 16 Fujitsu Siemens Rack Interface (RI) ports for connecting devices and oper ates over standard LAN connections. Access servers across a 100BaseT Ethernet connection or directly through an analog port on the KVM s2-1611 for analog KVM connectivity and administration. Video resolutions through the analog port can be up to 1600 x 1280 with an end-to-end cable length of up to 15 meters (50 feet). Digital users can achieve video resolution of up to 1280 x 1024 with a cable length of up to 10 meters (32 feet) between the KVM s2-1611 and the server.
The Fujitsu Siemens KVM series2-Adapters (KVM s2-Adapters) with CAT 5 design dramatically reduce cable clutter, while providing optimal digital display resolution and video settings. The built-in memory of the KVM s2-Adapter simplifies configuration by assigning and retaining unique server names or Electronic ID (EID) numbers for each attached server. This integrated intelligence enhances security and prevents unauthorized access to a server through cable manipulation. The KVM s2-Adapter is powered directly from the server and provides Keep Alive functionality even if the KVM s2-1611 is not powered.
Access via network connection
No special software or drivers are required on the attached computers. Digital users access the KVM s2-1611 and all attached systems via Ethernet from a PC running the KVM series2-Client (KVM s2-Client or Client) software. This software resides on the user’s PC only. User PCs can be located anywhere a valid network connection exists. The KVM s2-1611 can be configured on a separate network from your data network, allowing access to your servers even if your applications network is down.
Point and click control with KVM s2-Client software
The KVM s2-Client software is a cross-platform management application that allows you to view and control the KVM s2-1611 and all attached servers.
The Client software provides secure authentication, data transfers and username/
KVM series2-Adapter

password storage. By utilizing a browser interface for navigation with an intuitive split-screen interface, this software provides you with a single point of access for your entire system. From here, you can manage the KVM s2-1611, install a new KVM s2-1611 or launch a video session to a system server. Multiple servers can be accessed by one user; each additional computer’s video will appear in a separate program window.
Throughout the documentation and KVM s2-Client user interface, you will see the word “appliance” used generically to describe the KVM s2-1611 switch.
It is essential to read the following “Safety notes” chapter before starting to work with the KVM s2-1611. That chapter contains essential information for proper installation and handling of the KVM s2-1611 device.
This manual describes how to install the KVM s2-1611 and explains how to config ure and operate the appliance.
The following notational conventions are used in this manual:
Bold This indicates emphasis in the text.
Key This indicates keys or key combinations in continuous text.
Italics This indicates commands, file names, menu names and inputs in con
tinuous text.
This indicates additional information and tips.
This indicates information, which if not heeded, may jeopardize your
health, the functioning of your system or the security of your data.
This indicates a step that you have to perform.
- and • These characters symbolize itemized lists.
Preface · Safety notes · Title

This chapter provides radio frequency and safety information for your appliance.
United States radio frequency information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian radio frequency information
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le Ministère des Communications du Canada.
Japanese radio frequency information


Safety notes Precautions and rack mount safety
Avoiding potential video and/or keyboard problems when using the KVM s2-1611
Avoiding potentially fatal shock hazard and possible damage to equipment
The AC inlet is the main disconnect.
Rack mount safety considerations

3.1 Preinstallation
The KVM s2-1611 system requires that the KVM s2-Client software be installed prior to use. The KVM s2-Client software allows you to view and control a server attached to the appliance system, configure and maintain the system and prevent unauthorized access to the appliance via IP connection.
The analog port does not require the Client software for operation. The analog port uses the On-Screen Configuration and Activity Reporting interface (OSCAR®).
The KVM s2-1611 system uses Ethernet networking infrastructure and TCP/IP protocol to transmit keyboard, video and mouse information between operators and connected computers. Although 10BaseT Ethernet may be used, a dedicated, switched 100BaseT network provides improved performance.
Before installing your KVM s2-1611 appliance, refer to the following list to ensure you have all items that shipped with the appliance as well as other items neces sary for proper installation.
3.1.1.1 Supplied with the KVM series2-1611
3.1.1.2 Additional items needed
The KVM s2-1611 system uses IP addresses to uniquely identify the appliances and the computers running Client software. The KVM s2-1611 appliance supports both BootP (a subset of DHCP) and static IP addressing.
Fujitsu Siemens recommends that IP addresses be reserved for each unit and that they remain static while the appliances are connected to the network.

3.1.3 Rack mounting your appliance
Your KVM s2-1611 appliance ships with rack mounting brackets for easy integra tion into your rack. Before installing the appliance and other components in the rack cabinet (if not already installed), stabilize the rack in a permanent location. Install your equipment starting at the bottom of the rack cabinet, then work to the top. Avoid uneven loading or overloading of rack cabinets.
3.1.3.1 Installing the rack mount brackets
Line up the holes in the “long side” of the kit’s side brackets with the screw holes in the switch.
With a Phillips screwdriver, fasten the mounting brackets to the switch using two 8/32” x 1/2” pan head screws on each side.
Attach the four cage nuts or clip nuts to the rack mounting flange of the rack cabinet so that the nut is positioned on the inside of the rack.
Mount the switch assembly to the rack cabinet by matching the holes in the “short side” of each bracket to an appropriate set of matching holes on your rack cabinet. Next, insert the combination hex head screws through the slots in the bracket and the holes in the mounting rail, then into the cage nuts or clip nuts.

KVM series2-1611

3.2 KVM series2-1611 hardware
The following table lists the port and connection information for your appliance.
Types PS/2, Sun and USB KVM s2-Adapters
Sync Types Separate horizontal and vertical
Plug and Play DDC2B
Video Resolution Analog Port Maximum: 1600 x 1280 @ 75 Hz Digital Port Maximum 1280 x 1024 @ 75 Hz
Type Serial RS232 with terminal set to 9600 baud, 8 bits, 1 stop bit, no parity and no flow control
Type PS/2 and VGA
Connectors PS/2 MiniDIN and 15-pin D

3.2.1 Power ratings
Heat Dissipation 92 BTU/Hr
Power Consumption 25 W
AC-input power 40 W maximum
AC-input voltage rating 100 to 240 VAC Autosensing
AC-input voltage rating 100 to 240 VAC Autosensing
AC-input current rating 1A
AC-input cable 18 AWG three-wire cable, with a three-lead IEC-320 receptacle on the power supply end and a country or region dependent plug on the power resource end
(H x W x D) 4.45 x 43.18 x 27.94 cm 1U form factor (1.75 x 17.00 x 11.00 in)
Weight 3.6 kg (8 lb) without cables
Temperature 10º to 50º Celsius( 50º to 122º Fahrenheit) operating -20º to 60º Celsius (-4º to 140º Fahrenheit) nonoperating
Humidity 20 to 80% noncondensing operating 5 to 95% noncondensing nonoperating
Agency Approvals EN55022 Class A, EN55024, EN61000-3-3, FCC15 Class A, VCCI Class A, IEC950, EN60950, UL 1950/60950 third edition, CSA C22.2 No. 950
KVM series2-1611 · Airflow 8 cfm · AC-frequency 50/60 Hz

3.3 Installing the KVM series2-1611
Figure 2 illustrates one possible configuration for your KVM s2-1611 appliance. Follow the detailed set of procedures following Figure 2 to successfully install your appliance.

Reducing the risk of electric shock or damage to your equipment
is an important safety feature.
accessible at all times.
from either the electrical outlet or the unit.
KVM series2-1611 · RI Port

3.3.1 Installing the KVM series2-1611 hardware
Connect a terminal or PC running terminal emulation software (such as HyperTerminal) to the configuration port on the back panel of the appliance using a RS232 DB9 null modem cable. The terminal should be set to 9600 baud, 8 bits, 1 stop bit, no parity and no flow control.
Plug the supplied power cord into the back of the appliance and then into an appropriate power source.
When you turn on the power, the Power indicator on the front of the unit will
blink for 30 seconds while performing a self-test. Approximately 10 seconds after it stops blinking, press the Enter key to access the main menu.
You will see the Terminal Applications menu with six options. Select option 1, Network Configuration.

Select option 1 to set your network speed. When possible, you should set your connection manually without relying on the auto negotiate feature. Once
KVM series2-1611

you enter your selection, you will be returned to the Network Configuration menu.
Select option 2 and specify if you are using a static or BootP IP address. Use a static IP address for ease of configuration. If you are using a BootP address, please configure your BootP server to provide an IP address to the appliance, skip step 4 and continue to the next procedure.
Select options 3-5 from the Terminal Applications menu, in turn, to finish configuring your appliance for IP address, Netmask and Default Gateway. Once this is completed, type a Ø (zero) to return to the main menu.
Before a server can be connected to the KVM s2-1611, an adjustment to mouse acceleration must be made. Use the default Microsoft® Windows® PS/2 mouse driver for all attached Microsoft Windows systems attached to the appliance.
3.3.3.1 Adjusting the mouse using Microsoft Windows NT® (using default drivers)
From the desktop, select Start - Settings - Control Panel - Mouse.
Click on the Motion tab.
Set the pointer speed to Slow. You will need to set this for any Windows NT user account that will be accessing the Windows NT system through the appliance.
3.3.3.2 Adjusting the mouse using Microsoft Windows 2000/Windows XP
From the desktop, select Start - Settings - Control Panel - Mouse.
Click on the Motion tab.
Set the Acceleration setting to None and the speed setting to the default of 50%.
3.3.3.3 Adjusting the mouse using Solaris
Open the Workspace menu on your desktop.
Select Applications - Application Manager - Desktop_Controls.
Open the Mouse Style Manager and set the Acceleration to 1.0.
Locate the KVM s2-Adapters for your KVM s2-1611 unit.
Attach the appropriately color-coded cable ends to the keyboard, monitor and mouse ports on the first server you will be connecting to the unit.
KVM series2-1611

Attach one end of the CAT 5 cabling that will run between your KVM s2-Adapt er and unit to the RJ45 connector on the KVM s2-Adapter.
Connect the other end of the CAT 5 cable to the desired Rack Interface (RI) port on the back of your KVM s2-1611 unit.
Repeat steps 2-4 for all servers you wish to attach.

When connecting a Sun KVM s2-Adapter, you must use a multi-sync monitor to accommodate Sun computers that support both VGA and sync-on-green or composite sync.
You can add your cascade switches to the KVM s2-1611 system for better inte gration into your existing configuration. In a cascaded system, each RI port will accommodate up to 24 servers.
Tiered KVM s2 Appliance Cascade to a KVM s2-1611, 1602 or 0801 via a CAT 5 cable con nected from an RI port to the ACI port on the KVM s2-1602
KVM s2-Adapter PS/2, USB and Sun cables are available
1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16
KVM series2-1611 · KVM s2-1611

Mount the KVM switch into your rack cabinet. Locate a length of CAT 5 cabling to connect your appliance to the KVM s2-Adapter for your switch.
Attach one end of the CAT 5 cabling to the RJ45 connector on the KVM s2- Adapter.
Connect the other end of the CAT 5 cable to a port on the back of your KVM s2-1611.
Attach the keyboard, monitor and mouse connectors of the KVM s2-Adapter to a user port on your cascade switch.
Connect the servers to your Fujitsu Siemens cascade switch according to the instructions included with the device.
Power cycle the switch to enable the cascade code.
Repeat steps 2-5 for all cascade switches you want to attach to your system.
You can also cascade a KVM s2-1611 off of a KVM s2-1602/0801. To do this, attach one end of a CAT 5 cable to the ACI port on the main KVM s2-1602/0801. Attach the other end of the CAT 5 cable to an RI port on the cascaded KVM s2-1611. Note that only one level of tiering is supported in this type of configuration and the local port OSCAR is disabled when the main KVM s2-1602/0801 is cascaded below the KVM s2-1611. See the KVM series2-1602/0801 User Guide for more information on this process.
Connect your network cable from the LAN port on the rear of the KVM s2- 1611 appliance to your network.
The components in the KVM s2-1611 system may be turned on in any order. However, since the KVM s2-Adapters are powered by the servers, turn on the servers first and then turn on all attached systems for the most efficient startup.
See the KVM series2-Client Installer/User Guide that ships with your appliance.
The KVM s2-1611 system has an analog port that allows you to attach a monitor and a PS/2 keyboard and mouse to the back of the unit. First, set up your servers at the analog port via OSCAR before proceeding to the Client software to finish configuring your system. Proceed to the “Operations” chapter in this installer/user guide for detailed instructions on OSCAR setup and configuration. Once your servers are named, you will want to use a digital station to configure the Client
KVM series2-1611

software. See the KVM series2-1611 Quick Installation Guide for an overview of the hardware and software installation procedure.
KVM series2-1611

The KVM s2-1611 includes an analog port on the back of the unit that allows you to connect a monitor and a PS/2 keyboard and mouse for direct analog access. The appliance uses OSCAR®, the On-Screen Configuration and Activity Report ing interface, which utilizes intuitive menus to configure your system and select computers.
Use the OSCAR Main dialog box to view, configure and control servers in the KVM s2-1611 system. View your servers by name, port or by the unique Electronic ID number (EID) embedded in each KVM s2-Adapter. You will see an OSCAR-gener ated port list by default when you first launch OSCAR.
The Port column indicates the RI port to which a server is connected. If you con nect a legacy KVM switch to the appliance, the port numbering displays the RI port first, then the switch port to which the server is connected. For example, in Figure 5, servers 06-03 and 01-02 are connected to switches.
Press Print Screen to launch OSCAR. The Main dialog box appears.


You can also press the Control key twice within one second to launch OSCAR. You can use this key sequence in any place you see Print Screen throughout this installer/user guide.
The status of the servers in your system is indicated in the right columns of the Main dialog box. The following table describes the status symbols.
KVM s2-Adapter is online.
KVM s2-Adapter is offline or is not operating properly.
KVM s2-Adapter is being accessed by the indicated user channel.
KVM s2-Adapter is blocked by the indicated user channel. For instance, in Figure 5, user B is viewing Forester, but is blocking access to Acton, Barrett and Edie which are connected to the same KVM s2- Adapter chain.
Use the Main dialog box to select servers. When you select a server, the appliance reconfigures the keyboard and mouse to the proper settings for that server.
Double-click the server name, EID or port number. -or- If the display order of your server list is by port (Port button is depressed), type the port number and press Enter . -or- If the display order of your server list is by name or EID number (Name or EID button is depressed), type the first few characters of the name of the server or the EID number to establish it as unique and press Enter .
4.2.3.1 Selecting the previous server
Press Print Screen and then Backspace. This key combination toggles you between the previous and current connections.
4.2.3.2 Disengaging the user from a server
Press Print Screen and then Alt+Ø . This leaves the user in a free state, with no server selected. The status flag on your desktop displays Free.

4.2.4 Soft switching
Soft switching is the ability to switch servers using a hot key sequence. You can soft switch to a server by pressing Print Screen and then typing the first few char acters of its name or number. If you have set a Screen Delay Time and you press the key sequences before that time has elapsed, OSCAR will not display.
4.2.4.1 Configuring servers for soft switching
Press Print Screen to launch OSCAR. The Main dialog box appears.
Click Setup - Menu. The Menu dialog box appears.
For Screen Delay Time, type the number of seconds of delay desired before
the Main dialog box is displayed after Print Screen is pressed.
Click OK.
4.2.4.2 Soft switching to a server
To select a server, press Print Screen. If the display order of your server list is
by port (Port button is depressed), type the port number and press Enter . -or- If the display order of your server list is by name or EID number (Name or EID button is depressed), type the first few characters of the name of the server or the EID number to establish it as unique and press Enter .
To switch back to the previous server, press Print Screen then Backspace.
This table describes how to navigate OSCAR using the keyboard and mouse.
Print Screen Opens OSCAR. Press Print Screen twice to send the Print Screen keystroke to the currently selected device.
F1 Opens the Help screen for the current dialog box.
Escape Closes the current dialog box without saving changes and returns to the previous one. In the Main dialog box, it closes OSCAR and returns to the flag. In a message box, it closes the pop-up box and returns to the current dialog box.

This Keystroke Does This
Alt Opens dialog boxes, selects or checks options and executes actions when used with underlined or other designated letters.
Alt+X Closes the current dialog box and returns to the previous one.
Alt+O Selects the OK button, then returns to the previous dialog box.
Single-click, Enter In a text box, it selects the text for editing and enables the Left and Right Arrow keys to move the cursor. Press Enter again to quit the edit mode.
Enter Completes a switch in the Main dialog box and exits OSCAR.
Print Screen, Backspace Toggles back to previous selection.
Print Screen, Alt+ Ø Immediately disengages user from a server; no server is selected. Status flag displays Free. (This only applies to the Ø on the keyboard and not the keypad.)
Print Screen, Pause Immediately turns on screen saver mode and prevents access to that particular console, if it is password protected.
Up/Down Arrows Moves the cursor from line to line in lists.
Right/Left Arrows Moves the cursor between columns. When editing a text box, these keys move the cursor within the column.
Page Up/Page Down Pages up and down through Name and Port lists and Help pages.
Home/End Moves the cursor to the top or bottom of a list.
Backspace Erases characters in a text box.
Delete Deletes current selection in the scan list or characters in a text box.
Shift-Del Deletes from the current selection to the end of the list when editing a scan list.
Numbers Type from the keyboard or keypad.
Caps Lock Disabled. Use the Shift key to change case.

4.4 Configuring OSCAR
You can configure your KVM s2-1611 system from the Setup menu within OSCAR. Select the Names button when initially setting up your appliance to identify servers by unique names. Select the other setup features to manage routine tasks for your servers from the OSCAR menu.
Menu Change the server listing between numerically by port or EID number and alphabetically by name. Change the Screen Delay Time before OSCAR displays after pressing Print Screen .
Flag Change display, timing, color or location of the status flag.
Broadcast Set up to simultaneously control multiple servers through keyboard and mouse actions.
Scan Set up a custom scan pattern for up to 16 servers.
Security Set passwords to restrict server access. Enable the screen saver.
Devices Identify the appropriate number of ports on an attached cascade switch.
Names Identify servers by unique names.
Press Print Screen to launch OSCAR. The Main dialog box appears.
Click Setup. The Setup dialog box appears.


Use the Names dialog box to identify individual servers by name rather than by port number. The Names list is always sorted by port order. Names are stored in the KVM s2-Adapter, so even if you move the cable/server to another RI port, the name and configuration will be recognized by the appliance.
If a server is turned off, its respective KVM s2-Adapter will not appear in the Names list.
4.4.2.1 Accessing the Names dialog box
Press Print Screen . The Main dialog box will appear.
Click Setup - Names. The Names dialog box appears.


If the server list changes, the mouse cursor will turn into an hourglass as the list is automatically updated. No mouse or keyboard input will be ac cepted until the list update is complete.
4.4.2.2 Assigning names to servers
In the Names dialog box, select a server name or port number and click Modify. The Name Modify dialog box appears.

Type a name in the New Name box. Names of servers may be up to 15 characters long. Legal characters include: A-Z, a-z, Ø-9, space and hyphen.
Click OK to transfer the new name to the Names dialog box. Your selection is not saved until you click OK in the Names dialog box.
Repeat steps 1-3 for each server in the system.
Click OK in the Names dialog box to save your changes. -or- Click X or press Escape to exit the dialog box without saving changes.
If a KVM s2-Adapter has not been assigned a name, the EID is used as the default name.
While the appliance automatically discovers cascade switches attached to your unit, you will need to specify the number of ports on the cascade switch through the Devices dialog box. The appliance recognizes KVM switches. You will see an Sw-8 or Sw-24 appear in the Type category. When you select that switch from the list, the Modify button appears, allowing you to assign the appropriate number of ports to it.

4.4.3.1 Accessing the Devices dialog box
Press Print Screen. The Main dialog box will appear.
Click Setup - Devices. The Devices dialog box appears.
The Modify button will only be available if a configurable switch is selected.

When the KVM s2-1611 appliance discovers a cascade switch, you will notice the port numbering change to accommodate each server under that switch. For ex ample, if the switch is connected to RI port 6, the switch port would be listed as 06 and each server under it would be numbered sequentially 06-01, 06-02 and so on.
4.4.3.2 Assigning a device type
In the Devices dialog box, select the desired port number.
Click Modify. The Device Modify dialog box appears.


Choose the number of ports supported by your switch and click OK.
This appliance does not support 24 port switches at this time.
Repeat steps 1–3 for each port that needs a device type assigned.
Click OK in the Devices dialog box to save settings.
Changes made in the Device Modify dialog box are not saved until you click OK in the Devices dialog box.
Use the Menu dialog box to change the display order of servers and set a Screen Delay Time for OSCAR. The display order setting alters how servers will display in several screens including the Main, Devices and Broadcast dialog boxes.
4.4.4.1 Accessing the Menu dialog box
Press Print Screen to launch OSCAR. The Main dialog box appears.
Click Setup - Menu in the Main dialog box. The Menu dialog box appears.


4.4.4.2 Choosing the default display order of servers
Select Name to display servers alphabetically by name. -or- Select EID to display servers numerically by EID number. -or- Select Port to display servers numerically by port number.
Click OK.
4.4.4.3 Setting a Screen Delay Time for OSCAR
Type in the number of seconds (Ø-9) to delay OSCAR display after you press Print Screen. Entering Ø will instantly launch OSCAR with no delay.
Click OK.
Setting a Screen Delay Time allows you to complete a soft switch without OSCAR displaying. To perform a soft switch, see Soft switching in this chapter.
The status flag displays on your desktop and shows the name or EID number of the selected server or the status of the selected port. Use the Flag dialog box to configure the flag to display by server name or EID number, or to change the flag color, opacity, display time and location on the desktop.

OSCAR Flag Description
Flag type by name
Flag type by EID number
Flag indicating that the user has been disconnected from all systems
Flag indicating that Broadcast mode is enabled
4.4.5.1 Accessing the Flag dialog box
Press Print Screen . The Main dialog box will appear.
Click Setup - Flag. The Flag dialog box appears.

4.4.5.2 Determining how the status flag is displayed
Select Name or EID to determine what information will be displayed.
Select Displayed to show the flag all the time or select Timed to display the flag for only five seconds after switching.
Select a flag color in Display Color.
In Display mode, select Opaque for a solid color flag or select Transparent to see the desktop through the flag.

To position the status flag on the desktop: a. Click Set Position to gain access to the Position Flag screen. b. Left-click on the title bar and drag to the desired location. c. Right-click to return to the Flag dialog box.
Changes made to the flag position are not saved until you click OK in the Flag dialog box.
Click OK to save settings. -or- Click X to exit without saving changes.
OSCAR enables you to set security on your analog port console. You can estab lish a screen saver mode that engages after your console remains unused for a specified Inactivity Time. Once engaged, your console will remain locked until you press any key or move the mouse. You will then need to type in your password to continue.
Use the Security dialog box to lock your console with password protection, set or change your password and enable the screen saver.
If a password has been previously set, you will have to enter the password before you can access the Security dialog box.
4.4.6.1 Accessing the Security dialog box
Press Print Screen . The Main dialog box will appear.
Click Setup - Security. The Security dialog box appears.


4.4.6.2 Setting or changing the password
Single-click and press Enter or double-click in the New text box.
Type the new password in the New text box and press Enter . Passwords must contain both alpha and numeric characters, are case sensi tive and may be up to 12 characters long. Legal characters are: A-Z, a-z, Ø-9, space and hyphen.
In the Repeat box, type the password again and press Enter .
Click OK to change only your password, and then close the dialog box.
If you should lose or forget your password, you must return your switch. See theTechnical Support section for contact information.
4.4.6.3 Password protecting your console
Set your password as described in the previous procedure.
Select Enable Screen Saver.
Type the number of minutes for Inactivity Time (from 1 to 99) to delay activa tion of password protection and the screen saver feature.
For Mode, select Energy if your monitor is Energy Star®compliant; otherwise select Screen.
Monitor damage can result from the use of Energy mode with monitors not compliant with Energy Star®.
(Optional) Click Test to activate the screen saver test which lasts 10 seconds
Monitor Damage

then returns you to the Security dialog box.
Click OK.
4.4.6.4 Logging in to your console
Press any key or move the mouse.
The Password dialog box appears. Type your password, then click OK.
The Main dialog box appears if the password was entered properly.
4.4.6.5 Removing password protection from your console:
From the Main dialog box, click Setup - Security; the Password dialog box ap pears. Type your password, then click OK.
In the Security dialog box, single-click and press Enter or double-click in the New box. Leave the box blank. Press Enter .
Single-click and press Enter or double-click in the Repeat box. Leave the box blank. Press Enter .
Click OK to eliminate your password.
4.4.6.6 Enabling the screen saver mode with no password protection
If your console does not require a password to gain access to the Security dialog box, proceed to step 2. -or- If your console is password protected, see the previous procedure, then go to step 2.
Select Enable Screen Saver.
Type the number of minutes for Inactivity Time (from 1–99) to delay activation of the screen saver.
Choose Energy if your monitor is Energy Star® compliant; otherwise select Screen.
Monitor damage can result from the use of Energy mode with monitors not compliant with Energy Star®.
(Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you to the Security dialog box.
Click OK.
Monitor Damage

Activation of the screen saver mode disconnects the user from a server; no server is selected. The status flag displays Free.
4.4.6.7 Exiting the screen saver mode
Press any key or move your mouse. The Main dialog box appears and any previ ous server connection will be restored.
4.4.6.8 Turning off the screen saver
In the Security dialog box, clear Enable Screen Saver.
Click OK.
4.4.6.9 Immediately turning on the screen saver
Press Print Screen, then press Pause .
You can view and disconnect users through the User Status dialog box. The user name (U) will always be displayed; however, you can display either the server name or EID number to which a user is connected. If there is no user currently connected to a channel, the user field will be blank and the server field will display Free.
Press Print Screen . The Main dialog box will appear.
Click Commands - User Status. The User Status dialog box appears.
4.5.1.1 Disconnecting a user
Press Print Screen . The Main dialog box will appear.
Click Commands - User Status. The User Status dialog box appears.
Click the letter of a user to disconnect. The Disconnect dialog box will appear.



Click OK to disconnect the user and return to the User Status dialog box. -or- Click X or press Escape to exit the dialog box without disconnecting a user.
If the User Status list has changed since it was last displayed, the mouse cursor will turn into an hourglass as the list is automatically updated. No mouse or keyboard input will be accepted until the list update is complete.
If your keyboard or mouse locks up, you may be able to re-establish operation of these peripherals by issuing a reset command. The reset command sends a key sequence to the server which causes the mouse and keyboard settings to be sent to the appliance. With communication re-established between the server and the appliance, functionality is restored to the user.
Press Print Screen . The Main dialog box will appear.
Click Commands - Reset PS/2. A message box displays indicating that the mouse and keyboard have been reset.
Click X to close the message box.
OSCAR enables you to display the KVM s2-1611 and KVM s2-Adapter firmware versions. For optimum performance, keep your firmware current. For more infor mation, see Chapter 5.

Press Print Screen . The Main dialog box will appear.
Click Commands - Display Versions. The Version dialog box appears. The top half of the box lists the subsystem versions in the appliance.

Click Digital to view the Digitizer unit firmware versions. The Digital Version dialog box appears. The top section identifies the Digitizer subsystem ver sions. The center section identifies the current network settings. Click X or press Escape to return to the Version dialog box.

Click KVMS2 (see Figure 17) to view individual KVM s2-Adapter version infor mation. The KVM s2-Adapter Selection dialog box appears.


Select a KVM s2-Adapter to view and click the Version button. The KVM s2- Adapter Version dialog box appears. For more information on loading firm ware, see Chapter 5.

Click X to close the Version dialog box.
In scan mode, the appliance automatically scans from port to port (server to server). You can scan up to 16 servers, specifying which servers to scan and the number of seconds that each server will display. The scanning order is determined by placement of the server in the list. The list is always shown in scanning order. You can, however, choose to display the server’s name or EID number by press ing the appropriate button.

Scanning is only available to the analog user.
Press Print Screen . The Main dialog box will appear.
Click Setup - Scan. The Scan dialog box appears.

Determine the order within the list to add the server. If there are no servers in
the scan list, your cursor will appear in a blank line at the top of the list. -or- To add a server to the end of the list, place your cursor in the last server entry and press the Down Arrow key. -or- To add a server in the midst of an existing list, place your cursor in the line below where you want to insert a new server and press Insert .
Type the first few characters of a server name or port number to scan. The
first matching server will appear in the line. -or- To move through the list, press the following keyboard commands in the Name, Port or Sec column to move through the list of servers available to scan.
a. Press Alt+Down Arrow to move the cursor down through the list
of servers.
b. Press Alt+Up Arrow to move the cursor up through the list of servers.
c. Press Alt+Home to move the cursor to the first server in the list.

d. Press Alt+End to move the cursor to the last server in the list.
In the Sec column, type the number of seconds (from 3 to 255) of desired time
before the scan moves to the next server in the sequence.
Move the cursor to the next line or press the Down Arrow and repeat steps 2-5
for each of the remaining servers to be included in the scan pattern.
Click OK.
In the Scan dialog box, click the server to be removed.
Press Delete . -or- Press Shift+Delete to remove the selected server and all entries below it.
Click OK.
Press Print Screen . The Main dialog box will appear.
Click Commands. The Commands dialog box appears.

Select Scan Enable in the Commands dialog box.
Click X to close the Commands dialog box.
Scanning will commence when the Main dialog box or flag is displayed. Scanning is inhibited in any other OSCAR dialog box.

4.8.4 Cancelling scan mode
Select a server if OSCAR is open.
-or- Move the mouse or press any key on the keyboard if OSCAR is not open. Scanning will stop at the currently selected server. -or- Press Print Screen . The Main dialog box will appear.
Click Commands. The Commands dialog box appears.
Clear Scan Enable.
The analog user can simultaneously control more than one server in a system, to ensure that all selected servers receive identical input. You can choose to broad cast keystrokes and/or mouse movements independently.
You can broadcast to up to 16 servers at a time, one server per RI port.
Press Print Screen . The Main dialog box will appear.
Click Setup - Broadcast. The Broadcast dialog box appears.

When broadcasting keystrokes, the keyboard state must be identical for all servers receiving a broadcast to interpret keystrokes identically. Specifi cally, the Caps Lock and Num Lock modes must be the same on all key boards. While the appliance attempts to send keystrokes to the selected servers simultaneously, some servers may inhibit and thereby delay the transmission.

When broadcasting mouse movements, all systems must have identical mouse drivers, desktops (such as identically placed icons) and video resolu tions for the mouse to work accurately. In addition, the mouse must be in ex actly the same place on all screens. Because these conditions are extremely difficult to achieve, broadcasting mouse movements to multiple systems may have unpredictable results.
4.9.1.1 Broadcasting to selected servers:
From the Broadcast dialog box, select the mouse and/or keyboard checkbox es for the servers that are to receive the broadcast commands. -or- Press the Up or Down Arrow keys to move the cursor to the target server. Then press Alt+K to select the keyboard checkbox and/or Alt+M to select the mouse checkbox. Repeat for additional servers.
Click OK to save the settings and return to the Setup dialog box. Click X or press Escape to return to the Main dialog box.
Click Commands. The Commands dialog box appears.
Click the Broadcast Enable checkbox to activate broadcasting.
From the user station, type the information and/or perform the mouse move
ments you want to broadcast.
4.9.1.2 Turning broadcasting off
From the Commands dialog box, clear the Broadcast Enable checkbox.
Each individual KVM s2-1611 may be configured at the unit level through the configuration port on the back of the unit. All Terminal commands are accessed through a terminal or PC running terminal emulation software.
The KVM s2-1611 Terminal Applications menu features five selections: Network Configuration, Firmware Management, Enable Debug Messages, Set/Change Password and Exit.

4.10.1.1 Accessing the Terminal menu
Connect a terminal or PC running terminal emulation software (such as
HyperTerminal) to the configuration port on the back panel of the KVM s2- 1611 using a RS232 DB9 null modem cable. The terminal should be set to 9600 baud, 8 bits, 1 stop bit, no parity and no flow control. The terminal may be connected at any time, even when the unit is powered.
Press any key to access the main menu.
The KVM s2-1611 is configured for network access through the Network Configuration option. When it is selected, you will have access to the addressing that allows the KVM s2-1611 to be positioned in your network. For more information, see Installing the KVM s2-1611 in Chapter 3.
4.10.2.1 Firmware Management
This menu option contains the FLASH Download command. The FLASH Down load selection allows you to keep your KVM s2-1611 firmware current with up grades available from Fujitsu Siemens. For more information, see Chapter 5.
4.10.2.2 Enable Debug Messages
This menu option allows you to configure the KVM s2-1611 to display messages regarding the status of the KVM s2-1611. Once you select the level of detail to receive, the KVM s2-1611 will begin to display information on your terminal screen. When you are finished viewing, press any key to exit this mode.
4.10.2.3 Set/Change Password
The KVM s2-1611 can be set to a secure mode where the Terminal menu cannot

be accessed without first entering a password.
4.10.2.3.1 Activating security
Select the Set/Change Password menu option. You will be prompted with the option to continue. Enter a Y .
Type a password for this KVM s2-1611 and press Enter. This password must
be a minimum of 5 characters and can be up to a maximum of 12 characters (10 are visible). The password must consist of a combination of alpha and numeric characters.
You will be prompted to re-type the password. Once you complete this step,
security will be active and you will not be able to access KVM s2-1611 termi nal operations without the password.
4.10.2.3.2 Changing the password
Select the Set/Change Password menu option.
You will be prompted to type the old password and a new one.
Re-enter the new password to verify.
This password places your KVM s2-1611 terminal in a secure mode. This pass word should be guarded like any network password and care should be taken to avoid forgetting or misplacing it. There are no means for recovering a lost pass word.
4.10.2.4 Exit
This menu selection will return you to the ready prompt.

5.1 FLASH Upgrades
The KVM s2-1611 FLASH upgrade feature allows you to upgrade your unit with the latest firmware available. To perform this update you will need a TFTP server. If you don’t already have a TFTP server, there are several you can download from the internet.
If you upgrade the appliance firmware, please verify the individual firmware of the KVM s2-Adapters. The upgrade of the adapters requires a separate upgrade procedure which is found in Chapter 4.
Next, you will need to copy the FLASH upgrade file (.fl file extension) from the CD. Save the FLASH upgrade file to the appropriate directory on the TFTP server. Once this is complete, the following steps will upload the new FLASH file.
When upgrading your switch firmware, ensure that the keyboard coun try codes with your system correspond with the firmware loaded in your switch. Contact Fujitsu SiemensTechnical Support for more informa tion. Technical Support contact information is available at the end of this manual. 5.1.1. Uploading a new FLASH file
Connect a terminal or PC running terminal emulation software (such as
HyperTerminal) to the configuration port on the back panel of the KVM s2-1611 using a straight-through null modem cable. The terminal should be set to 9600 baud, 8 bits, 1 stop bit, no parity and no flow control.
Connect the LAN port on the KVM s2-1611 to an Ethernet hub that is also
connected to the PC being used as the TFTP server.
Launch both the server software and the terminal emulation software.
Verify that the KVM s2-1611 is turned on. After approximately 40 seconds, the
KVM s2-1611 will send out a message, Fujitsu Siemens KVM series2-1611 Ready__Press any key to continue. Press any key to access the main menu. The KVM s2-1611 main menu appears.
Get the IP address of the TFTP server: If using the SolarWinds TFTP server, it
appears in the lower right-hand corner of the server’s pane. Otherwise, extract it from the OS tools (may be OS-dependent): a. Right-click on Network Neighborhood. b. Select Properties. c. Select the Protocols tab. d. Select TCP/IP protocol. e. Select Properties and note the IP address.

Upgrading the firmware Appendices
Assign the IP address in the KVM s2-1611, if needed:
a. In the HyperTerminal window, type 1 to select Network Configuration.
b. Note the KVM s2-1611 IP address. The first three numbers must be the
same as in the server’s IP address from step 5 above. The last number must be different. If the KVM s2-1611 IP address is not correct, change it as follows: type 3 to select IP address, then enter the correct address.
c. Type Ø to exit the Network Configuration menu. If you changed the IP
address, wait per the directions on the screen.
From the main menu, type 2 to select Firmware Management. The current version of your firmware displays in the Firmware Management screen.
From the Firmware Management menu, type 1 to select FLASH Download.
Type the IP address of the TFTP server and press Enter .
Type the name of the FLASH file and press Enter .
Confirm the TFTP download by typing y or yes and pressing Enter .
The KVM series2-1611 will verify the file you downloaded is valid. Next you
will be prompted to confirm the upgrade. Type y or yes and Enter .
The KVM series2-1611 will begin the FLASH upgrade process. On-screen indi cators will display the upgrade process. When the upload is complete, the KVM series2-1611 will reset and upgrade the internal subsystems.
Do not cycle power to the KVM s2-1611 during this process. A loss of power might render the appliance inoperable and require the unit be re turned to the factory for repair. This upgrade may take up to 10 minutes to complete.
Once the upgrade is complete, the startup message from step 4 will appear
on the terminal screen.
The KVM s2-Adapters can be upgraded individually or simultaneously.
Do not cycle power to the server or disconnect the KVM s2-Adapter during this process. A loss of power will render the KVM s2-Adapter inoperable and require the switch to be returned to the factory for repair.
5.1.2.1 Simultaneously upgrading multiple KVM s2-Adapters
Press Print Screen . The Main dialog box will appear.
Click Commands - KVM s2-Adapter Status. The KVM s2-Adapter Status
dialog box appears.
Power Loss


Click one or more types of adapters to upgrade. Click Upgrade.

The KVM s2-Adapter Upgrade dialog box appears. Click OK to initiate the upgrade and return to the KVM s2-Adapter Status dialog box.
5.1.2.2 Upgrading KVM s2-Adapter firmware individually
Press Print Screen . The Main dialog box will appear.
Click Commands - Display Versions. The Version dialog box appears.
Upgrading firmware Appendices

Upgrading firmware individually Appendices
Click KVMS2 to view individual cable version information.
Select a KVM s2-Adapter to upgrade and click the Version button. The KVM s2-Adapter Version dialog box appears.

Upgrading firmware individually Appendices
Click the Load Firmware button. The Load dialog box appears.

Click OK to initiate the upgrade and return to the Status dialog box.
During an upgrade, the KVM s2-Adapter status indicator in the Main dialog box will be yellow. The KVM s2-Adapter is unavailable while an upgrade is in progress. When an upgrade is initiated, any current connection to the server via the KVM s2-Adapter will be terminated.
Certain keys on a standard Type 5 (US) Sun keyboard may be emulated by key press sequences on a PS/2 keyboard. To enable Advanced Sun Key Emulation mode and use they keys, press and hold Ctrl+Shift+Alt and then press the Scroll

Appendices Sun Advanced Key Emulation
Lock key. The Scroll Lock LED blinks. Use the indicated key in the following table as you would use the advanced keys on a Sun keyboard.
Vol. + keypad +
Vol. - keypad -
Command (left) (2) F12
Command (left) (2) Win (GUI) left (1)
Command (right) (2) Win (GUI) right (1)
(1) Windows 95 104-key keyboard (2) The Command key is the Sun Meta (diamond) key
For example: For Stop + A, press and hold Ctrl+Shift+Alt and press Scroll Lock, then F1 + A .
These key combinations will work with the USB KVM series2-Adapters (if your Sun system comes with a USB port) as well as the Sun KVM series2- Adapters. With the exception of Scroll Lock+F12, these key combinations are not recognized by Microsoft Windows. The Scroll Lock+F12 combination performs a Windows key press.

Our Technical Support staff is ready to assist you with any installation or operat ing issues you encounter with your Fujitsu Siemens product. If an issue should develop, follow the steps below for the fastest possible service:
Check the pertinent section of this manual to see if the issue can be resolved by following the procedures outlined.
Check our web site at www.fujitsu-siemens.com/support and click on Services & Support. Click helpdesk on the left side of the page for a listing of technical support phone numbers in your area.
Appendices Technical Support



Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Germany
Corrections
Comments on KVM series2-1611
Submitted by




Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.