EN
Fujioh logo
Official user manual

Fujioh BUF-01

14 pages·553 KB·Ventilation Hood·PDF·ENDEFRITNLJA
Fujioh BUF-01
Table of Contents 13 sections Installation Manual RANGE HOOD · MODEL:BUF-01 · BUF-02 · 1U030584 · … ShowHide
Page 1 of the Fujioh BUF-01 user manual — 1U030584
Page 1 · click to enlarge
Page 1

Installation Manual RANGE HOOD

MODEL:BUF-01

BUF-02

Fujioh BUF-01 — Installation Manual RANGE HOOD diagram (page 1)
Fig. 1 · Installation Manual RANGE HOOD
Fujioh BUF-01 — Installation Manual RANGE HOOD diagram (page 1)
Fig. 2 · Installation Manual RANGE HOOD
Fujioh BUF-01 — Installation Manual RANGE HOOD diagram (page 1)
Fig. 3 · Installation Manual RANGE HOOD
Fujioh BUF-01 — Installation Manual RANGE HOOD diagram (page 1)
Fig. 4 · Installation Manual RANGE HOOD

TABLE OF CONTENTS Safety Instructions 2 Name of Parts 4 Size & Dimensions 4 Range Hood Location 5 Installation 6

1. Preparation 6 2. Range Hood Mounting 8 3. Connecting Power Supply Wires 10 4. Final Assembly and Check 12 5. Explanation to the End User 13 Circuit Diagram 13

READ AND SAVE THESE INSTRUCTIONS. Keep this manual in a convenient place for future reference.

FUJI INDUSTRIAL CO., LTD.

1U030584

Page 2 of the Fujioh BUF-01 user manual — WARNING
Page 2 · click to enlarge
Page 2

○ SAFETY INSTRUCTIONS

Before installation and operation, read these instructions carefully and use this product only in the manner described by the manufacturer in the operation manual. The signal words shown below are used to alert you to potential personal injury and property damage hazards. There are three hazard classifications based on potentially dangerous situations. Obey all safety instructions that show these symbols to avoid possible injury, death and property damage.

result in death or serious injury. CAUTION: CAUTION indicates a potentially hazardous situation which, if not avoided, may

result in minor or moderate injury. CAUTION: CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

WARNING

1. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. b) Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

2. To reduce the risk of fire or electric shock, do not use this product with any solid-state speed control device.

3. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and The American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d) Ducted fan must always be vented to outdoors.

4. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
5. This unit must be grounded.
6. Install this range hood to a liner. Check that the hood is correctly installed, since incorrect installation could result in the range hood becoming detached and falling off.
7. Connect only to an AC120 Volt power source or the range hood could result in fire, electric shock, and damage.
Page 3 of the Fujioh BUF-01 user manual — CAUTION
Page 3 · click to enlarge
Page 3

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors.
2. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings or into attics, crawl spaces or garages.
3. Read specification label on this product for further information and requirements.
4. Use only for the purpose of kitchen ventilation.
5. Do not install this range hood in the bathroom or in other wet rooms since electrical shock and damage may result.
6. Fasten the filter and other parts securely. Incorrect attachment may result in personal injury or property damage.
7. Keep your hands and other objects away from the fan while it is in motion. The range hood may injure you or damage itself.

pictographic symbols.

: means prohibition. It indicates actions, if any, that

mustn’t be done.

: means forcible execution. It indicates actions, if any,

that must be done.

Page 4 of the Fujioh BUF-01 user manual — CAUTION
Page 4 · click to enlarge
Page 4
Fujioh BUF-01 — CAUTION diagram (page 4)
Fig. 5

- Accessories - - Accessories - - Accessories - - Accessories - - Accessories - Screw M5×30 Four (4) pieces

Fujioh BUF-01 — CAUTION diagram (page 4)
Fig. 6
Page 5 of the Fujioh BUF-01 user manual — CAUTION
Page 5 · click to enlarge
Page 5

RANGE HOOD LOCATION

The range hood must be installed just above the cooktop.

The minimum distance from the cooking surface to the bottom of the range hood must be 24".

The total weight of the BUF-01/BUF-02 range hood unit is:

BUF-01/BUF-02 18 lbs. (8 kg)

Power requirements are:

BUF-01 AC120 V, 60 Hz, 1.3 Amp BUF-02 AC120 V, 60 Hz, 2 Amp

CAUTION

  • Check that the hood is correctly installed, since incorrect installation could result in the detachment of the range hood and the unit fall.
  • To protect hands from injury, wear working gloves when installing the range hood.
Page 6 of the Fujioh BUF-01 user manual — CAUTION
Page 6 · click to enlarge
Page 6

INSTALLATION

1. PREPARATION

  • WARNING
  • If the range hood is not installed properly, it could become detached and fall.
  • Ensure that the metal duct does not touch other metal housing materials, otherwise fire or electric shock could result.

This range hood is designed to discharge upward. For vertical discharge, run duct work between the hood location and roof cap location. To get the best result, use a minimum number of transitions and elbows. Be sure to attach a roof cap to avoid leaking rain in the end.

The range hood unit must be mounted to a liner which has the following dimensions. Install the liner securely after checking that the opening size of the liner is the same as the figure below.

CAUTION

The liner should be installed tightly. If the liner installation is not correct, the range hood unit may become detached and fall.

Page 7 of the Fujioh BUF-01 user manual — INSTALLATION
Page 7 · click to enlarge
Page 7
Fujioh BUF-01 — INSTALLATION diagram (page 7)
Fig. 7

Run house wiring between service panel and hood location.

supplied) to connect the exhaust pipe and external duct. The diameter of the transition duct should be more than 6".

Page 8 of the Fujioh BUF-01 user manual — INSTALLATION
Page 8 · click to enlarge
Page 8
Fujioh BUF-01 — INSTALLATION diagram (page 8)
Fig. 8

Hold up the range hood unit and insert it into the opening of the liner. When the 4 securing plates on both sides have passed through the top of the liner, turn them outward to secure the range hood on the liner temporarily. Make sure that the top of the exhaust pipe is inserted into the bottom of the transition duct.

Page 9 of the Fujioh BUF-01 user manual — INSTALLATION
Page 9 · click to enlarge
Page 9
Fujioh BUF-01 — INSTALLATION diagram (page 9)
Fig. 9

Remove 4 screws which are fixed to the front cover. The front cover swings open 90° as shown in Fig.

Align 4 screw holes of the liner and range hood unit, then fix securely using the supplied screws and nuts.

Make the duct joint secure and air tight using non-flammable tape such as duct tape, etc. (not supplied)

Page 10 of the Fujioh BUF-01 user manual — 3. CONNECTING POWER SUPPLY WIRES
Page 10 · click to enlarge
Page 10

3. CONNECTING POWER SUPPLY WIRES

  • WARNING
  • Electrical wiring should be done by a qualified person(s) in accordance with allapplicable codes and standards, including fire-rated construction. An unqualified person doing the work could result in fire, electric shock or injury.
  • This range hood uses 120V AC. Do not connect to other voltage since fire, electric shock or damage could result.

Remove the nut from the conduit connector at the end of power wiring.

Remove one screw fixing the wire cover and detach it.

Connect the conduit through the connecting hole of the body using the nut previously removed.

Page 11 of the Fujioh BUF-01 user manual — 3. CONNECTING POWER SUPPLY WIRES
Page 11 · click to enlarge
Page 11
Fujioh BUF-01 — 3. CONNECTING POWER SUPPLY WIRES diagram (page 11)
Fig. 10

Connect the electrical wires as follows: Connect wires tightly and securely using wire connectors (not supplied).

  • Black to Black
  • White to White
  • Green to Green

Replace the wire cover with the screw removed previously. Make sure that all wires are connected properly and enclosed inside of the wiring compartment.

Page 12 of the Fujioh BUF-01 user manual — 4. FINAL ASSEMBLY AND CHECK
Page 12 · click to enlarge
Page 12

4. FINAL ASSEMBLY AND CHECK

One 40 W light bulb (not supplied) can be mounted to this range hood. Prior to final assembly, install a light bulb (ordinary type, in the base diameter 17 mm: intermediate base), rated 120 V-40 W or below.

Assembly Replace the front cover with 4 screws.

Check (1) Turn on the electrical circuit to the range hood. (2) Make sure that the switch and light operate correctly. Refer to page 4 of the

Operation Manual. (3) Check the ventilating functions at Hi, Me and Lo positions. (4) Make sure that the range hood has no abnormal noises and/or vibration.

  • CAUTION
  • To reduce the risk of injury, keep your hands and other objects away from the fan while it is in motion.
  • Wear working gloves to avoid injury.
Page 13 of the Fujioh BUF-01 user manual — CIRCUIT DIAGRAM
Page 13 · click to enlarge
Page 13

5. EXPLANATION TO THE END USER

(1) Refer to the Operation Manual, explain the operation of this range hood to end

users. (2) The Installation Manual and Operation Manual should be given to the end user.

CIRCUIT DIAGRAM

White Orange Brown Blue

Bulb:Max40W

White Orange Brown Blue

Show 17 more labels / short text on this page
120V 60Hz · Motor · Green · Connector · Terminal · Black · White · Capacitor Red · White · Orange Brown Blue · Red · Green · Black · Connector · Green Black · Red · Control Switch
Page 14 of the Fujioh BUF-01 user manual — 1U030584
Page 14 · click to enlarge
Page 14

Fuji Industrial USA, Inc. 16300 Christensen Rd., Ste-212 Seattle, WA 98188-3403 Telephone: 1-888-547-9880

1U030584

Ask about the Fujioh BUF-01

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fujioh BUF-01

Be the first to ask — other owners or our team will answer.

Original document

Fujioh BUF-01 manual PDF

14 pages·553 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…