PL36WC51EC PL42WC51EC

! INTENDED FOR DOMESTIC COOKING ONLY !
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this unit with any separate solid-state speed control device. 8. To reduce the risk of fire, use only metal ductwork. 9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef
Flambe’). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
! CAUTION 1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 5. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 6. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 7. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface. See “Install Mounting Bracket” section for mounting restrictions. 8. Two installers are recommended because of the large size and weight of this hood. 9. Please read specification label on product for further information and requirements.

LIGHT SWITCH
PILOT
MEDIUM
SPEED
LAMP
The hood is operated using the (4) push-buttons located at eye-level, on the front edge of the hood.
The light switch turns the halogen lamps on and off.
HIGH SPEED
OFF SWITCH
The blower on-low / off switch turns the blower on to its lowest running speed. The blower must be turned on using this switch. Turn the blower off by pressing this switch a second time.
The blower medium speed switch changes the blower speed to medium. This switch works only if the blower is already running at low or high speed.
The blower high speed switch changes the blower speed to high. This switch works only if the blower is already running at low or medium speed.
The pilot lamp lights up whenever the blower is on.
This range hood requires two halogen bulbs (Type GU10, MR16 shielded, 120V, 50W). ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

RING NUT
MAINTENANCE
Proper maintenance of the Range Hood will assure proper performance of the unit.
Grease Filters The grease filters should be cleaned frequently. Use a warm detergent solution. Grease filters are dishwasher safe.
See “INSTALL FILTERS” section for removal and installation instructions.
Non-Ducted Recirculation Filters The non-ducted recirculation filters should be changed every 6 months.
See “INSTALL FILTERS” section for removal and installation instructions.
Hood Cleaning Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance. Cleaning tips:
Controls

Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag containing: 1 - Mounting Bracket 1 - Discharge Collar 1 - Flue Mounting Bracket 8 - Mounting Screws (4,8 x 38mm Pan Head) 4 - Mounting Screws (3,9 x 9,5mm Pan Head) 2 - Mounting Screws (3.9 x 6mm Flat Head) 8 - Drywall Anchors 1 - Installation Instructions
DISCHARGE COLLAR
4 MOUNTING SCREWS (3.9 x 9.5mm Pan Head)

2 MOUNTING BRACKET SCREWS (3.9 x 6mm Flat Head)
FLUE MOUNTING BRACKET
8 MOUNTING SCREWS (4.8 x 38mm Pan Head)


! CAUTION: To reduce the risk of fire, use only metal ductwork.
WALL
CAP
HOOD
24” TO 30” ABOVE COOKING SURFACE (see
“INSTALL MOUNTING BRACKETS” section for

SUPPORT
(DUCTED AND NON-DUCTED HOODS)

the framing within the dimensions shown.
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a)
DRYWALL WOOD CROSS SUPPORT
24” 25” 26” 27” 28” 29”
8-FOOT
10- FOOT (see note b) 39-7/8” 40-7/8” 41-7/8” 42-7/8” 41-7/8” 42-7/8”

DRYWALL ANCHORS
3.9 x 6 mm FLAT HEAD BRACKET SCREWS

7-3/4” (196.8 mm)
4.8x38mm MOUNTING SCREWS

(DUCTED HOODS ONLY)
Install the discharge collar into the duct connector of the range hood. Fig. 9.

5”-6” ADAPTER 3.9x6mm FLAT HEAD
BRACKET


FIG.10 FIG.11
INSTALL THE HOOD
(DUCTED AND NON-DUCTED HOODS) Note: at least two people will be required to mount the hood.
1. Raise the hood into its mounting position. 2. Align the rectangular opening on the back of the hood with the wall-mounting bracket. Gently lower the hood until it securely engages the bracket. Fig. 12. 3. Level the hood with 2 mounting screws (3.9x9.5mm) and secure with (4) mounting screws. Use drywall anchors provided if wall studs or framing are not available. Fig. 12. 4. On ducted hoods, attach 6” round metal duct between the hood’s blower collar and duct that leads to the outside location. 5. On non-ducted hoods, attach 5” round metal expandable duct between the 5”-6” adapter on the hood and the connector on the plenum. 6. Tape all duct joints to make them secure and air tight. 7. Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue.
(4.8x38mm)
MOUNTING SCREWS

(3.9x9.5mm)
(4.8x38mm)
BRACKET
RECTANGULAR
CUTOUT

ROOMS WITH 10-FOOT CEILINGS (DUCTED HOODS ONLY) Rooms with 10-foot ceilings require flue extension model FXWC51EC available from your local dealer. 9. Discard the upper flue supplied with the product. Replace it with the flue extension. 10. Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 14. 12. Secure the flue with (2) 3.9x9.5mm mounting screws. Fig. 14.
UPPER FLUE
VENTS CONCEALED
3.9x9.5mm MOUNTING SCREWS


LOWER FLUE
INSTALL FILTERS
(DUCTED AND NON-DUCTED HOODS)


FILTERS