Table of Contents 77 sections MODELS PL30DD & PL36DD DOWNDRAFT BLOWER SYSTEM READ AND SAVE THESE INSTRUCTIONS · ! INTENDED FOR DOMESTIC COOKING ONLY ! · WARNING · CAUTION ! · … ShowHide
MODELS PL30DD & PL36DD DOWNDRAFT BLOWER SYSTEM READ AND SAVE THESE INSTRUCTIONSp.1! INTENDED FOR DOMESTIC COOKING ONLY !p.1WARNINGp.1CAUTION !p.1PLANNINGp.1TYPICAL INSTALLATIONp.1COUNTERp.1CHIMNEY TOPp.1TOPp.1COOK TOPp.1AIR VENTp.1GEAR MOTOR COVERp.1BLOWERp.1BOXp.1120 VAC GROUNDED OUTLETp.13-1/4" X 10" DUCT CONNECTORp.1PLANNING - (continued)p.2PLAN THE DUCTWORKp.2RIGHT DISCHARGEp.2SPECIFICATIONSp.2LEFT DISCHARGEp.2TAKE MEASUREMENTSp.26" ROUND ELBOWp.23-1/4" X 10" TO 6" RD. TRANSITIONp.2EQUALS 2 FT. OF STRAIGHT DUCTp.2EQUALS 6 FT. OF STRAIGHT DUCTp.23-1/4" X 10" 90 O ELBOWp.2EQUALS 8 FT. OF STRAIGHT DUCTp.2PLAN THE WIRINGp.2PREPARATIONp.3CUT COUNTERTOP OPENINGp.3CHANGING BLOWER DISCHARGE (Optional)p.3DOWN DISCHARGE - MOVING BLOWER LEFT OR RIGHTp.3SHEET METAL SCREWp.3NUTSp.3CLAMP CHANNELp.3BOTTOM FLANGEp.3MOUNT THE UNITp.3MOUNTING SCREWSp.3LEFT OR RIGHT DISCHARGEp.3LEVELING BRACKET - FLANGE FACING OUTp.3NUTp.3MOTOR PLUGp.3LEVELING BRACKET - FLANGE FACING INp.3COVER PLATEp.3INSTALL DUCTWORKp.4WIRING DIAGRAMp.4COLLAR SCREWSp.46" RD. ELBOW & DUCTWORKp.4INSTALL COOKTOPp.4ADJUSTMENTp.4INSTALL ELECTRICAL WIRINGp.4SWITCH MEMBRANEp.4SCREWSp.4SWITCH COVERp.4SWITCH BRACKETp.4USE AND CAREp.5USE AND CARE - (Continued)p.5CLEANINGp.5CONTROLSp.5KNOBp.5SERVICINGp.5SERVICE PARTSp.6Models PL30DD & PL36DD Downdraft Blower Systemp.6OPTIONAL TOP COVER KITSp.6Major Appliance Warranty Informationp.8DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIESp.8L5V 3E4p.899043820Ap.8DOWNDRAFT TOP COVER ASSEMBLYp.9INSTALLATIONp.9TOP COVERp.9LEGp.9ACTIVATINGp.9SWITCHp.9COVERp.999043821Ap.10
Page 1 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — 3-1/4" X 10" DUCT CONNECTOR
Page 1 · click to enlarge
Page 1

MODELS PL30DD & PL36DD DOWNDRAFT BLOWER SYSTEM READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au- thorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Do not use this range hood with an additional speed control device. 7. Ducted fans must always be vented to the outdoors. 8. To reduce the risk of fire, use only metal ductwork. 9. Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the burner should be 4 inches. 10.Loose-fitting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop. 11.Children should not be left alone or unattended in the area where this appliance is in use. 12.When flaming foods, turn the blower OFF. An operating blower may spread the flames. 13. This unit must be grounded. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when cooking flaming foods. 3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immedi ately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher, and you

already know how to operate it. B. The fire is small and contained in the area where it

started. C. The fire department is being called. D. You can fight the fire with your back to an exit. a Based on “Kitchen Firesafety Tips” published by NFPA.

CAUTION !

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Clean filters and grease-laden surfaces frequently. 4. Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician. 5. Please read specification label on product for further informa- tion and requirements.

PLANNING

Frigidaire Professional Series Downdraft Vent (PL36DD) — PLANNING diagram (page 1)
Fig. 1

This downdraft blower system is designed to be used to exhaust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, peninsula, or conventional wall locations.

TYPICAL INSTALLATION

COUNTER

CHIMNEY TOP

TOP

COOK TOP

AIR VENT

GEAR MOTOR COVER

This unit can be easily installed following these basic steps:

BLOWER

  • Cut out the countertop opening.

BOX

120 VAC GROUNDED OUTLET

  • Mount the unit in the cabinet.
  • Connect the ductwork and electrical.
  • Install the cooktop.

3-1/4" X 10" DUCT CONNECTOR

INSTALLER: Save this manual for Electrical Inspector and Homeowner to use.

HOMEOWNER: Use and Care Information on Page 5.

Page 2 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — PLAN THE WIRING
Page 2 · click to enlarge
Page 2

PLANNING - (continued)

PLAN THE DUCTWORK

Frigidaire Professional Series Downdraft Vent (PL36DD) — PLANNING - (continued) diagram (page 2)
Fig. 2 · PLANNING - (continued)

RIGHT DISCHARGE

SPECIFICATIONS

LEFT DISCHARGE

VOLTSAMPSCFMDUCT 1204.05003-1/4 X 10

DOWN DISCHARGE (as shipped)

1. This downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Three different discharge directions are available with side-to-side adjustment for accurate alignment of ductwork.

TAKE MEASUREMENTS

2. For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. NOTE: The unit is shipped with the 3-1/4" x 10" discharge facing DOWN. See “CHANGING BLOWER DIRECTION” on page 3, if necessary.
1. Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The Model PL30DD will fit in most 30" wide cabinets and the Model PL36DD will fit in most 36" wide cabinets. However, it is recommended that oversized cabinets be used for easier installation.
Frigidaire Professional Series Downdraft Vent (PL36DD) — TAKE MEASUREMENTS diagram (page 2)
Fig. 3

6" ROUND ELBOW

3-1/4" X 10" TO 6" RD. TRANSITION

2. Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.

EQUALS 2 FT. OF STRAIGHT DUCT

EQUALS 6 FT. OF STRAIGHT DUCT

Frigidaire Professional Series Downdraft Vent (PL36DD) — EQUALS 2 FT. OF STRAIGHT DUCT diagram (page 2)
Fig. 4

3-1/4" X 10" 90 O ELBOW

EQUALS 8 FT. OF STRAIGHT DUCT

3. The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less.

Pay special attention to the areas of potential interference high- lighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2" of flat countertop is required behind cooktop and that 1-3/4" is necessary between the back edge of the cooktop and the inside of cabinet back.

PLAN THE WIRING

1. The downdraft blower system draws 4 AMPS and requires a 120 VAC, 60 Hz circuit.
2. The unit has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach. (Note: If the Model PL30DD is being installed in a 30" wide cabinet or the Model PL36DD is being installed in a 36" wide cabinet, the outlet cannot be located on the back wall of cabinet.) Outlet may also be wall-mounted, with access hole in cabinet.
Page 3 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — MOTOR PLUG
Page 3 · click to enlarge
Page 3

PREPARATION

CUT COUNTERTOP OPENING

CHANGING BLOWER DISCHARGE (Optional)

1. Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will fit behind it.
2. Set cooktop in place and slide it as far forward as possible. Center and square it with edges of countertop.

The blower is shipped with its discharge facing DOWN. Follow these steps ONLY if:

Frigidaire Professional Series Downdraft Vent (PL36DD) — CHANGING BLOWER DISCHARGE (Optional) diagram (page 3)
Fig. 5 · CHANGING BLOWER DISCHARGE (Optional)
  • the position of the blower discharge needs to be moved so ductwork does not interfere with floor joists, plumb ing or wiring below.
  • it is necessary to rotate the blower discharge to the RIGHT or LEFT.

Place the unit on its back on a table or work surface.

DOWN DISCHARGE - MOVING BLOWER LEFT OR RIGHT

SHEET METAL SCREW

Frigidaire Professional Series Downdraft Vent (PL36DD) — DOWN DISCHARGE - MOVING BLOWER LEFT OR RIGHT diagram (page 3)
Fig. 6

BLOWER

NUTS

CLAMP CHANNEL

3. Place the plastic template against the back flange of the cooktop and center it. Trace around template to mark the downdraft opening.
4. Remove cooktop from countertop.
5. Cut downdraft opening. Be careful not to chip edges of countertop.

BOTTOM FLANGE

1. Loosen the 4 nuts and 2 clamp channels.
2. Slide blower to desired position.
3. Use supplied cover plate to close open space (if any).

MOUNT THE UNIT

4. Tighten wing nuts to secure top of blower and use sheet metal screws through bottom flange to secure bottom of blower.
Frigidaire Professional Series Downdraft Vent (PL36DD) — MOUNT THE UNIT diagram (page 3)
Fig. 7

MOUNTING SCREWS

LEFT OR RIGHT DISCHARGE

LEVELING BRACKET - FLANGE FACING OUT

BLOWER

NUT

Frigidaire Professional Series Downdraft Vent (PL36DD) — MOUNTING SCREWS diagram (page 3)
Fig. 8

MOTOR PLUG

CLAMP CHANNEL

LEVELING BRACKET - FLANGE FACING IN

SHEET METAL SCREW

COVER PLATE

1. Set downdraft into opening. Extend leveling brackets to floor of cabinet so downdraft sits straight. (Note: Leveling brackets can be removed and re-attached in other positions. Bottom flange may have to face inward in tight cabinet installations.)
1. Remove the 4 nuts and 2 clamp channels.
2. Carefully lift blower and disconnect motor plug if necessary. Reposition blower and RECONNECT MOTOR PLUG.
2. Secure the downdraft to the countertop as follows: Hold the downdraft against the back of countertop cut-out and tightening the 2 mounting screws (one on each end of unit) on underside of countertop. Use a wood shim between screw and underside of granite countertops.
3. Use supplied cover plate to close open space (if any).
4. Replace clamp channels and use nuts to secure the blower in its new position.
5. Use sheet metal screws through bottom flange to secure bottom of blower.
3. Screw leveling brackets to bottom of cabinet. Tighten screws holding leveling bracket to unit on each side.
Page 4 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — SWITCH COVER
Page 4 · click to enlarge
Page 4

INSTALL DUCTWORK

WIRING DIAGRAM

Frigidaire Professional Series Downdraft Vent (PL36DD) — INSTALL DUCTWORK diagram (page 4)
Fig. 9
Frigidaire Professional Series Downdraft Vent (PL36DD) — INSTALL DUCTWORK diagram (page 4)
Fig. 10

➡

➡

BLOWER

3-1/4" X 10" TO 6" RD. TRANSITION

COLLAR SCREWS

6" RD. ELBOW & DUCTWORK

INSTALL COOKTOP

1. Align the cooktop with the downdraft and fasten cooktop in place.
1. Cut hole in cabinet as well as holes in wall or floor as necessary.
2. Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight.

ADJUSTMENT

The downdraft is factory-adjusted for proper operation. However, shipping and handling may affect the position of the activating switch.

3. Connect ductwork (and transition, if required) to downdraft. If necessary, LOOSEN nuts and screws that hold the blower in place, and slide blower left or right to meet ductwork. Retighten screws and nuts.

To adjust position of activating switch:

1. If downdraft is plugged into electrical outlet, unplug it.

INSTALL ELECTRICAL WIRING

2. Lift air vent straight up and cock it slightly so it remains in the UP position.
1. Mount a standard wiring box, with 3-pronged receptacle, inside the cabinet. Make sure the downdraft’s power cord can easily reach it.
Frigidaire Professional Series Downdraft Vent (PL36DD) — INSTALL ELECTRICAL WIRING diagram (page 4)
Fig. 11

SWITCH MEMBRANE

2. Run appropriate power cable into cabinet and connect it to receptacle.

SCREWS

3. Plug the downdraft’s power cord into the outlet.

SWITCH COVER

SWITCH BRACKET

3. Remove switch cover from right end of air vent.
4. Loosen the 2 screws holding the switch bracket in place. Position switch bracket so that activating switch just comes in contact with underside of switch membrane. Tighten screws.
5. Replace switch cover, gently lower air vent into chimney, and plug in power cord. Re-connect electrical power and check operation.
Page 5 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — KNOB
Page 5 · click to enlarge
Page 5

USE AND CARE

USE AND CARE - (Continued)

Always turn the downdraft blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off. This will keep the whole kitchen cleaner and brighter.

CLEANING

CONTROLS

Use a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS. Vacuum blower to clean. Do not immerse blower in water.

Frigidaire Professional Series Downdraft Vent (PL36DD) — CONTROLS diagram (page 5)
Fig. 12

Wash the 2 aluminum grease filters in a mild detergent solution or a dishwasher. Remove them from the air vent by grasping the tab at the top of each filter.

Turn the downdraft blower ON by pressing down on the activating switch. The air vent will rise.

Frigidaire Professional Series Downdraft Vent (PL36DD) — CONTROLS diagram (page 5)
Fig. 13

KNOB

SERVICING

The blower can be turned ON or OFF and its speed can be adjusted with the recessed knob on the right side of the air vent.

It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism.

Frigidaire Professional Series Downdraft Vent (PL36DD) — KNOB diagram (page 5)
Fig. 14

Disconnect power to the cooktop and remove it first. Reverse the steps under “MOUNT THE UNIT” to remove the downdraft from the cabinet.

Turn the downdraft blower OFF by pressing the activating switch again. The air vent will go down and the blower will shut OFF.

Page 6 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — OPTIONAL TOP COVER KITS
Page 6 · click to enlarge
Page 6

SERVICE PARTS

Models PL30DD & PL36DD Downdraft Blower System

KEY NO.DESCRIPTIONQTY. 1 2 3 4 5 6 7 8 9 10 11 12 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31 32 33 45 46 47 49 50 51 52 53 54 55 56 57 58 59 60 61 62 64 65 66 67 68 70 71 73 74 75 84 ** **Bushing, 7/8" Bushing, Split Heyco, 5/8" Bushing, Heyco, 1/2" Roller Switch Assembly, Up/Down Wire Harness, Speed Control Nut, 3/8-32 Knob Motor Insolator Lower Switch Bracket Assembly Green Ground Wire Wire Harness Back-up Plate Crank Switch Cover Chimney Assembly with Slide Motor (with Capacitor-Key No. 73) Blower Wheel Scroll Box Extension Spacer Top Bracket Assembly, Right Top Bracket Assembly, Left Top, Stainless Scroll Box Assembly Gear Motor Cover Air Box Assembly Scroll Box Cover Capacitor Strap Filter Kit (contains 2 filters) End Cap Gearmotor Slide Strip Screw, #8-18 x .375 SLT HX WS HD Screw, #10-32 x .500 HX WS BDRH Screw, #8-18 x .375 SR PH TRH Screw, #8-18 x .500 No. 5 PH Trim Cover, Air Box Opening Nut, #10-24 Air Box Cover Gearmotor Bracket Assembly Leg Support Screw, 1/4-20 x 5/16 Washer, 1/4 Screw, #8-32 x 1/2 PH HD MS Screw, #10-24 x 3/8 SH WH LOCK Screw, #10-24 x 3/8 PH FL HD LD Nut, 10-24 HEX KEPS Nut, 1/4-20 WHIZ LOCK U-Bolt, 10-24 Strain Relief Nut, Hex Flange Wire Channel Clamp Wire Tie Capacitor Screw, 1/4-20 x 1.250 HEX HD #8-18 x .250 PH TR HD BPT Seal - Foam Blower Assembly, Complete (Includes Key Nos.2, 9, 20, 21, 22, 28, 31, 32, 49, 58, 64, 65, & 73) Chimney Assembly, Complete (Includes Key Nos. 5, 8, 19, 45, 51, 52, & 71)1 3 1 3 1 4 19 2 6 2 1 4 1 1 2 5 2 4 1 1 7 3 1 1 1 2 3 1 2 2 1

OPTIONAL TOP COVER KITS

MODEL NO.DESCRIPTION HT2730B HT2736B HT2730W HT2736W30" Black 36" Black 30" White 36" White

*Standard Hardware - May be purchased locally. **Service Assembly - Contains numerous parts.

Page 7 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — SERVICE PARTS
Page 7 · click to enlarge
Page 7

SERVICE PARTS

Models PL30DD & PL36DD Downdraft Blower System

Frigidaire Professional Series Downdraft Vent (PL36DD) — SERVICE PARTS diagram (page 7)
Fig. 15
Frigidaire Professional Series Downdraft Vent (PL36DD) — SERVICE PARTS diagram (page 7)
Fig. 16
Page 8 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — L5V 3E4
Page 8 · click to enlarge
Page 8

Major Appliance Warranty Information

Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.

This warranty does not cover the following:

1. Products with original serial numbers that have been removed, altered or cannot be readily determined.
2. Product that has been transferred from its original owner to another party or removed outside the USA or Canada.
3. Rust on the interior or exterior of the unit.
4. Products purchased "as-is" are not covered by this warranty.
5. Food loss due to any refrigerator or freezer failures.
6. Products used in a commercial setting.
7. Service calls which do not involve malfunction or defects in materials or workmanship, or for appliances not in ordinary household use or used other than in accordance with the provided instructions.
8. Service calls to correct the installation of your appliance or to instruct you how to use your appliance.
9. Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc., which are not a part of the appliance when it is shipped from the factory.
10. Service calls to repair or replace appliance light bulbs, air filters, water filters, other consumables, or knobs, handles, or other cosmetic parts.
11. Surcharges including, but not limited to, any after hour, weekend, or holiday service calls, tolls, ferry trip charges, or mileage expense for service calls to remote areas, including the state of Alaska.
12. Damages to the finish of appliance or home incurred during installation, including but not limited to floors, cabinets, walls, etc.
13. Damages caused by: services performed by unauthorized service companies; use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies; or external causes such as abuse, misuse, inadequate power supply, accidents, fires, or acts of God.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES

CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

If You Need Service

Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below.

This warranty only applies in the USA and Canada. In the USA, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed by Electrolux or an authorized service company. Product features or specifications as described or illustrated are subject to change without notice.

USA 1.800.944.9044 Electrolux Major Appliances North America P.O. Box 212378 Augusta, GA 30907

Canada 1.800.668.4606 Electrolux Canada Corp.

5855 Terry Fox Way Mississauga, Ontario, Canada

L5V 3E4

99043820A

Exclusions

Page 9 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — SWITCH
Page 9 · click to enlarge
Page 9

DOWNDRAFT TOP COVER ASSEMBLY

INSTALLATION

ADJUSTMENT

Frigidaire Professional Series Downdraft Vent (PL36DD) — DOWNDRAFT TOP COVER ASSEMBLY diagram (page 9)
Fig. 17

The downdraft is factory-adjusted for proper operation. How- ever, shipping and handling may affect the position of the activating switch.

To adjust position of activating switch:

TOP COVER

Frigidaire Professional Series Downdraft Vent (PL36DD) — TOP COVER diagram (page 9)
Fig. 18

LEG

ACTIVATING

SWITCH

1. If downdraft is plugged into electrical outlet, unplug it.
2. Lift air vent straight up and cock it slightly so it remains in the UP position.
Frigidaire Professional Series Downdraft Vent (PL36DD) — LEG diagram (page 9)
Fig. 19
1. Press activating switch to raise chimney. NOTE: If electrical power supply is not connected, lift chimney manually and cock it slightly to keep it in position. Remove four (4) screws and remove existing top cover.
2. Slide legs on top cover into ends of chimney as shown. Make sure switch membrane is above activating switch. Fasten with four (4) screws provided.

SWITCH

COVER

3. Remove switch cover from right end of air vent.
4. Loosen the 2 screws holding the switch bracket in place. Position switch bracket so that activating switch just comes in contact with underside of switch membrane. Tighten screws.
5. Replace switch cover, gently lower air vent into chimney, and plug in power cord. Re-connect electrical power and check operation.
Page 10 of the Frigidaire Professional Series Downdraft Vent (PL36DD) user manual — L5V 3E4
Page 10 · click to enlarge
Page 10

Major Appliance Warranty Information

Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.

This warranty does not cover the following:

1. Products with original serial numbers that have been removed, altered or cannot be readily determined.
2. Product that has been transferred from its original owner to another party or removed outside the USA or Canada.
3. Rust on the interior or exterior of the unit.
4. Products purchased "as-is" are not covered by this warranty.
5. Food loss due to any refrigerator or freezer failures.
6. Products used in a commercial setting.
7. Service calls which do not involve malfunction or defects in materials or workmanship, or for appliances not in ordinary household use or used other than in accordance with the provided instructions.
8. Service calls to correct the installation of your appliance or to instruct you how to use your appliance.
9. Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc., which are not a part of the appliance when it is shipped from the factory.
10. Service calls to repair or replace appliance light bulbs, air filters, water filters, other consumables, or knobs, handles, or other cosmetic parts.
11. Surcharges including, but not limited to, any after hour, weekend, or holiday service calls, tolls, ferry trip charges, or mileage expense for service calls to remote areas, including the state of Alaska.
12. Damages to the finish of appliance or home incurred during installation, including but not limited to floors, cabinets, walls, etc.
13. Damages caused by: services performed by unauthorized service companies; use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies; or external causes such as abuse, misuse, inadequate power supply, accidents, fires, or acts of God.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES

CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

If You Need Service

Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below.

This warranty only applies in the USA and Canada. In the USA, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed by Electrolux or an authorized service company. Product features or specifications as described or illustrated are subject to change without notice.

USA 1.800.944.9044 Electrolux Major Appliances North America P.O. Box 212378 Augusta, GA 30907

Canada 1.800.668.4606 Electrolux Canada Corp.

5855 Terry Fox Way Mississauga, Ontario, Canada

L5V 3E4

99043821A

Exclusions

Ask about the Frigidaire Professional Series Downdraft Vent (PL36DD)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frigidaire Professional Series Downdraft Vent (PL36DD)

Be the first to ask — other owners or our team will answer.

Original document

Frigidaire Professional Series Downdraft Vent (PL36DD) manual PDF

10 pages·225 KB·Blower·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…