To avoid electric shock, which can cause death or severe personal injury, disconnect the refrigerator from electrical power before connecting a water supply line to the refrigerator.
The following items will be required to install the ice maker kit.







Putty Knife Pliers ¼ inch Socket Wrench Needle Nose Pliers or Nut Driver Adjustable Wrench Knife

If condenser is mounted inside compressor compartment (D), remove screws securing sound baffle to cabinet (B).








To avoid electric shock, which can cause death or severe personal injury, disconnect the refrigerator from electrical power before connecting a water supply line to the refrigerator.
To Avoid Property Damage: Copper tubing is recommended for the water supply line. Water supply tubing made of 1/4 inch plastic is not
recommended since it greatly increases the potential for water leaks. Manufacturer will not be responsible for any damage if plastic tubing is used for supply line. DO NOT install water supply tubing in areas where temperatures fall below freezing. Connect the ice maker to a potable water source that is not tied into a water softening system. Chemicals from the
softener may damage the ice maker, causing it to malfunction.
Before Installing The Water Supply Line, You Will Need Basic tools: adjustable wrench, flat blade screwdriver, and PhillipsTM screwdriver.
Access to a household cold water line with water pressure between 20 and 120 psi.
A water supply line made of 1/4 inch (6.4 mm) OD, copper tubing. To determine the length of copper tubing
needed, you will need to measure the distance from the ice maker inlet valve at the back of the refrigerator to your cold water pipe. Then add approximately 7 feet (2.1 meters), so the refrigerator can be moved out for cleaning.
A shutoff valve to connect the water supply line to your household water system. DO NOT use a self-piercing type
shutoff valve.
A compression nut and ferrule (sleeve) for connecting the water supply line to the ice maker inlet valve.
To Connect Water Supply Line To Ice Maker Inlet Valve 1. Disconnect refrigerator from electric power supply.
10.To turn ice maker on, lower wire signal arm. (See ice maker front cover for on/off position of arm.)

Remember that water quality determines your ice quality. Do not connect the ice maker to water that is softened. Chemicals from a malfunctioning softener can damage the ice maker.
To stop the ice maker, lift the wire signal arm until it clicks and locks in the up or OFF position. The ice maker turns off automatically when the ice container is full. If your model has an adjustable freezer shelf, place the shelf so the wire signal arm will hit the ice when the ice container is full.
Ice stored too long may develop an odd flavor. Empty the container and be sure the wire signal arm is in its down or ON position. The ice maker will then produce more ice. Occasionally shake the container to keep ice separated. Keep the wire signal arm in its up or OFF position until the refrigerator is connected to the water supply or whenever the water supply is turned off. The following sounds are normal when the ice maker is operating.
Motor running Ice loosening from tray Ice dropping into ice container Running water Water valve opening or closing
DO NOT place the ice container in your dishwasher.
Wash ice container in warm water with mild detergent. Rinse well and dry. Stop the ice maker when cleaning the freezer or for short vacations. If the ice maker will be turned off for a long period of time, turn the water supply valve to the closed position.
Ice Maker Tips