Dryer Tech Data Sheet This information is intended for Qualified Technicians Only. CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to its Envelope in the Product for Future Reference

FUNCTION TEST SEQUENCE 1. Non-Digital Readout Display Models: Position the cycle selector knob to the 12 O’clock position. Digital Readout Display Models: Position the cycle selector knob to the Normal cycle option. 2. Press and hold the Select and Pause Cancel buttons simultaneously for six seconds. 3. Immediately after, press and hold the START and Pause Cancel buttons simultaneously for 4 seconds. The control will enter test mode, the buzzer will sound 3 times and all LED’S will rapidly flash. After entering the test mode, the program knob can now be rotated to select the following tests: Rotate the program knob clockwise from the start position: 1 turn: Drive motor runs; heat source is on. Drying LED is lit. “H” and the control thermistor reading will toggle back and forth in the display.** 2 turns: Drive motor runs; heat source is off. Cool Down LED is lit and “AF” (Air Fluff) is displayed. 3 turns: Drive motor runs; heat source is off. Drying and Cool Down LED’s are lit and numbers appear in the display showing moisture sensor readings. Opening the door (press in on door switch plunger) and placing a finger on the both moisture sense bars at the same time will make the numbers decrease. In controls that do not have a digit display, the MORE DRY LED should be ON. Opening the door (press in on door switch plunger) and placing a finger on the both moisture sense bars at the same time will make the DAMP LED come on. 4 turns: Drive motor runs; heat source is off.
a. When the TEMP button is pressed, all the TEMP LED’s should light. If the Temp selector is the
rotary knob, and the knob is rotated, there should be a key beep with each setting. b. When the DRYNESS button is pressed, all the dryness level LED’s should light. c. When the OPTION or Select button is pressed, all the Option LED’s should light. d. When the START button is pressed, all the cycle status LED’s should light. e. When the Pause Cancel button is pressed, all the Cycle status LED’s should light. 5 turns: Drive motor runs; heat source is off. Cool Down LED is lit. Control thermistor reading is displayed.** 6 turns: Drive motor runs; heat source is on. Drying LED is lit. Control thermistor reading is displayed.** **For models that do not have a digital display, the dryness LED’S could be used to determine the control thermistor temperature reading. The number of flashes of the bottom three LED’S will determine the value of the temperature as follows.
Less Dry flashes 2 times (Less Dry = TEN’S) Damp flashes 6 times (Damp = ONE’S)

To EXIT the test mode, press and hold the SELECT and Pause Cancel buttons simultaneously for six seconds or disconnect power from dryer. Dryer will be reset for regular operation.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| E10 | Problem with communication between EEPROM and the microprocessor. | Clear code, exit mode and start dryer. If problem persists, replace electronic control. | p.1 |
| E11 | Problem with communications or memory did not check, one has become corrupted. | Clear code, exit mode and start dryer. If problem persists, replace electronic control. | p.1 |
| E12 | Problem reading or writing to the memory or input/output. | Clear code, exit mode and start dryer. If problem persists, replace electronic control. | p.1 |
| E24 | Control thermistor or its wiring is shorted. | Remove wires from control thermistor. Measure resistance of thermistor. If reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 10%), check wiring between thermistor and electronic control. If good, replace electronic control. | p.1 |
| E25 | Control thermistor or its wiring is open. | Remove wires from control thermistor. Measure resistance of thermistor. If reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 10%), check wiring between thermistor and electronic control. If good, replace electronic control. | p.1 |
| E4A | The drying time has exceeded program time for that cycle. | Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes. Position cycle selector to NORMAL, temperature selector to HIGH HEAT and touch START. Check for anything that would extend dry times such as: no heat, restricted vent, blower fan blade broken or loose, dryer installed in closet with solid door, or bad connection in moisture sensor bar circuit or dirty bars. If dryer operates normally but code returns, replace electronic control. | p.1 |
| E5B | Temperature reading of control thermistor has not changed in a certain amount of time. | Position cycle selector to NORMAL, temperature selector to HIGH HEAT and touch START. Measure voltage across terminals on relay K2 (heater relay) on electronic control. If meter reads 240V on electric models and 120V on gas models, replace electronic control. If meter reads zero, remove power from dryer. Disconnect wire going to NO terminal on the relay K2. Reconnect power and measure voltage drop between terminal COM on relay K2 and neutral. If meter reads zero, wire between incoming line and relay K2 is open. If meter reads 120V, check the rest of the heater circuit. | p.1 |
| E68 | One of the keys (buttons) is stuck closed (active). | Enter function test mode and perform key (button) test to determine which button is at fault. Carefully free the and perform the test again. If button is free but the key struck code still exists, replace electronic control. | p.1 |
| E8C | The safety (high limit) thermostat has tripped too many times within a certain period of program time. | Check for blocked lint filter, blocked exhaust, air leaks around air duct, broken blower fan blades, worn or loose drum seals, dryer installed in closet with solid doors or door seal not correctly seated. | p.1 |