Installation Checklist
Please read all instructions before using this freezer.
Handles are secure and tight Door seals completely to cabinet on all sides Freezer door is level across the top
liquids in the vicinity of this or any other appliance. Read product labels for warnings regarding fl ammability and other hazards. • DO NOT operate the freezer in the presence of
Freezer is level, side-to-side and tilted 1/4”
(6mm) front-to-back Kick plate is properly attached to freezer Cabinet is setting solid on all corners
explosive fumes. • Remove all staples from the carton. Staples can
cause severe cuts, and also destroy fi nishes if they come in contact with other appliances or furniture.
House power turned on Freezer plugged in
Ice Maker
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
House water supply connected to freezer No water leaks present at all connections -
recheck in 24 hours Ice maker is turned ON Front fi lter must be fl ush with fi lter housing
Shipping material removed Freezer temperatures set Registration card sent in
(select models)

Electrical Information
Destroy or recycle the carton, plastic bags, and any exterior wrapping material immediately after the freezer is unpacked. Children should NEVER use these items to play. Cartons covered with rugs, bedspreads, plastic sheets or stretch wrap may become airtight chambers, and can quickly cause suffocation.
Risk of child entrapment
Child entrapment and suffocation are not problems of the past. Junked or abandoned freezers or freezers are still dangerous – even if they will sit for “just a few days”. If you are getting rid of your old freezer or freezer, please follow the instructions below to help prevent accidents.
Proper Disposal of Refrigerators/Freezers
We strongly encourage responsible appliance recycling/ disposal methods. Check with your utility company or visit www.recyclemyoldfridge.com for more information on recycling your old freezer.
Before you throw away your old refrigerator/ freezer:


To disconnect power to the unit, unplug the unit or switch the breaker that supplies power to the unit to the off position.
These guidelines must be followed to ensure that safety mechanisms in this freezer will operate properly.


Your Frigidaire freezer is designed for optimal convenience and storage fl exibility. The illustration below is provided to
assist you with familiarizing yourself with product features and terminology.
Features may vary according to model.

Two Liter Adjustable Door

You will need the following tools:

This Use & Care Guide provides general operating instructions for your model. Use the freezer only as instructed in this Use & Care Guide. Before starting the freezer, follow these important fi rst steps.
Installation clearances: • Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections:
Sides - 3/8 inch Top and Back - 1 inch

If your freezer is placed with the door hinge side against a wall, you may have to allow additional space so the door can be opened wider.


DO NOT install the freezer where the temperature will drop below 55°F (13°C) or rise above 110°F (43°C). The compressor will not be able to maintain proper temperatures inside the freezer.
DO NOT block the kick plate on the lower front of your freezer. Suffi cient air circulation is essential for the proper operation of your freezer.
The exterior walls of the freezer may become quite warm as the compressor works to transfer heat from the inside. Temperatures as much as 30ºF warmer than room temperature can be expected.

1. Remove handle from carton and any other protective packaging. 2. Position freezer handle end caps over upper and lower pre-installed shoulder bolts (A) that are fastened into door, ensuring the holes for the set screws are facing towards the outside of door if a single unit installation or the freezer door (if installing the matching freezer) 3. While holding handle fi rmly against door, fasten upper and lower Allen set screws (B) with supplied Allen wrench. 4. Repeat steps 2 and 3 to install freezer handle (if installing the matching freezer). Ensure the holes for the set screws are facing towards the freezer door.
B
All set screws should be tightened and sub-fl ush (Allen set screw should be seated just below the surface of the end cap) of handle end cap. The end caps should be drawn tight to freezer door with no gaps.
To remove the kick plate, use a Phillips head screwdriver and remove the two screws holding the kick plate to the cabinet. Then pull the kick plate away from the unit.
Matching Freezer and Freezer Door Handle
Leveling instructions continued on next page.

While unit is lying on its back for wood skid removal, note the location of the four (4) leg levelers installed at each corner. These leg levelers will be used to level the freezer and to adjust the height. Use a carpenter’s level to level the freezer from front to back and side to side.
Use the lower hinge adjustment to fi ne tune the door height and for fi nal cabinet spacing. Use a 7/16” socket or wrench to adjust the screw at the bottom of the lower hinge.
Make sure to allow for the Trim and Leveling Kit if it is to be installed with the unit.
The doors may also be adjusted side to side with the slotted hinge for aligning the doors parallel to each other. Loosen the two bolts with a 3/8” wrench and one screw with a Phillips screwdriver. Shift the doors until parallel, then retighten the screws securely. (See illustration below.)
Lower Hinge Adjustment For Leveling The Doors Of The Matching Tall Refrigerator / Tall Freezer Pair
To level the doors using the adjustable lower hinge (some models): 1. If the freezer door is lower than the freezer door,


If door must be removed:
Doors are heavy. It is recommended to have two people to remove or replace the door assembly from the cabinet.
For safe food storage, allow four (4) hours for freezer to cool down completely. The freezer will run continuously for the fi rst several hours.
The Pro-Select™ Electronic Control is located inside the freezer. Temperature is factory preset to provide satisfactory food storage temperatures. However, the temperature control is adjustable to provide a range of temperatures for your personal satisfaction.

To adjust the temperature setting, press the UP (▲) key for warmer temperature and DOWN (▼) key for colder temperature on the control panel. Allow several hours for the temperature to stabilize between adjustments. The freezer can be adjusted between -10°F (-23°C) and 10°F (-12°C). By pressing the TEMP MODE key, the temperature display will toggle between °F to °C.
To turn the freezer OFF, press the UP (▲) key until the warmest temperature setting of 10Fº (-12Cº) shows in the display. Then press the UP (▲) key three (3) times within three (3) seconds to turn the freezer OFF. The display will then show “OF”. To turn the unit back ON, press the DOWN (▼) key three (3) times within three (3) seconds. The control will then display “10Fº (-12Cº)” and may be adjusted to the desired temperature.
Cool Down Period · Pro-Select™ Electronic Control


Air Filter Reset Key Temp Mode Key Alarm Reset Key
When the “REPLACE AIR FILTER” LED is illuminated yellow, the air fi lter needs to be replaced. The control will signal for air fi lter replacement after 3600 hours of freezer operation. After replacing the air fi lter, reset the air fi lter timer by pressing the AIR FILTER key for 3 seconds. The “REPLACE AIR FILTER” LED will be illuminated green for three (3) seconds, confi rming a timer reset.
Resetting Air Filter Alarm
To disable the keypads on the control, begin by pressing the CONTROL LOCK key for three seconds until “LO” is displayed for 1 second. With the control locked, when keys are pressed on the control panel, “LO” will be displayed. To unlock the control, press the CONTROL LOCK key for three seconds. The display will show “UL” for one second.

The POWER FAIL indicator light informs you that due to a power failure the cabinet temperature exceeded 23ºF (-5ºC). If the power failure lasted more than one (1) hour the display alternates between showing the power failure duration (Hours and DURATION LED illuminate in the display) and the cabinet temperature (ºF or ºC illuminates) every ½ second. This safety feature will aid in determining what food spoilage action to take.
The Power Fail indicator light and duration display can be turned off by pressing the Alarm Off Key.
Setting Control Lock · Power Fail Indicator

The Sabbath Mode is a feature that disables portions of the freezer and its controls in accordance with the observance of the weekly Sabbath and religious holidays within the Orthodox Jewish community.
To initiate or cancel Sabbath Mode, press the CONTROL LOCK and TEMP MODE keys at the same time and hold for three (3) seconds. The display will now show “Sb” and the confi rmation tone will sound. When AC power is cycled while the control is in Sabbath mode, the control enters into Sabbath mode automatically. “Sb” will again be displayed. While in Sabbath Mode, the display will show “Sb”.
In the interest of food safety, only the HIGH TEMP Alert remains active and takes precedence over other Sabbath Mode features.
For ice making, the wire signal arm of the ice maker must be lifted to its OFF position and ice cubes be made using a standard ice tray.
For further assistance, guidelines for proper usage and a complete list of models with the Sabbath feature, please visit the web at http:\\www.star-k.org
Your new Pure Advantage air fi lter is located inside one of the 2 Liter Door Bins. The air fi lter cover is located on the upper right side of the control box. In general, you should change the air fi lter with Part Number “EAFCBF” every six months to ensure optimal fi ltering of freezer odors. The replacement air fi lter can be purchased on the Frigidaire website (http://frigidaire.stores.yahoo.net) or call toll free in the U.S. and Canada: 1-800-599-7569. Your electronic control is equipped with a Change Filter Indicator to remind you to change your fi lter. See page 10.

Setting Sabbath Mode

There are four possible conditions that will cause the alert tone to sound.
If the temperature inside the cabinet has exceeded 23ºF (-5ºC) for 1 hour or more of normal operation, the HIGH TEMP LED will illuminate, the HIGH TEMP Alert will sound and the cabinet temperature is shown in the display. The LED and temperature alert will remain active until the cabinet temperature is below 23ºF (-5ºC).
The audible alert can be turned off by pressing Alert Reset key.

This alert will sound to alert you that the door has been open for 5 minutes or more. The DOOR AJAR LED will illuminate and the audible alert will sound until the door is closed.
The audible alert can be turned off by pressing the Alert Reset key or by closing the door. If the door is ajar for 15 minutes, the interior light will turn off.
The sensor alarm signals you that a problem exists with a temperature sensor. The audible alarm will sound after one (1) hour and the display will alternate between “E8” or “E9” and -10°F (-23°C) at ½ second intervals. The control will then enter a mode that runs the freezer in a manner that maintains the factory set cabinet temperature.
The audible alert can be turned off by pressing the Alert Reset key.
The stuck key alert will sound if the control reads a keypress for longer than 30 seconds. The audible alert will sound and will be limited to one minute and will stop automatically. The display will alternate between “E7” and -10°F (-23°C) at ½ second intervals and the control will run the freezer continuously until the condition is resolved.
The audible alert can be turned off by pressing the Alert Reset key.

To Connect Water Supply Line To Ice Maker Inlet Valve 1. Disconnect refrigerator from electric power source. 2. Place end of water supply line into sink or bucket. Turn ON water supply and fl ush supply line until water is clear. Turn OFF water supply at shutoff valve. 3. Remove plastic cap from water valve inlet and discard cap. 4. If you use copper tubing - Slide brass compression nut, then ferrule (sleeve) onto water supply line. Push water supply line into water valve inlet as far as it will go (¼ inch / 6.4 mm). Slide ferrule (sleeve) into valve inlet and fi nger tighten compression nut onto valve. Tighten another half turn with a wrench; DO NOT over tighten. See Figure A.
To avoid electric shock, which can cause death or severe personal injury, disconnect the freezer from electrical power before connecting a water supply line to the freezer.
Plastic Water Tubing Steel Clamp
Include enough tubing in loop to allow moving freezer out for cleaning.
Ensure that your water supply line connections comply with all local plumbing codes.
Copper Water Line From Household Water Supply
Figure A. Copper Water Line Connection
If you use stainless steel tubing - The nut and ferrule are already assembled on the tubing. Slide compression nut onto valve inlet and fi nger tighten compression nut onto valve. Tighten another half turn with a wrench; DO NOT over tighten. See Figure B.

If your freezer has an automatic icemaker, it will provide a suffi cient supply of ice for normal use. During the initial startup of your freezer, however, no ice will be produced during the fi rst 24 hours of operation.
Automatic ice makers are also optional accessories that may be installed in some models at any time. Call your local dealer for information.
After the plumbing connections have been completed, the water supply valve must be opened. Place the ice container under the ice maker, pushing it as far back as possible. Lower the wire signal arm to its “down” or ON position. New plumbing connections may cause the fi rst production of ice cubes to be discolored or have an odd fl avor. These fi rst cubes should be discarded until the cubes produced are free of discoloration and taste.
6 ft. Stainless Steel Water Line From Household Water Supply
Figure B. Stainless Steel Water Line Connection
To stop the ice maker, lift the wire signal arm until it clicks and locks in the “up” or OFF position. The ice maker also turns off automatically when the ice container is full. If your model has an adjustable freezer shelf, place the shelf in the lower position, so that the wire signal arm will hit the ice when the container is full.
5. With steel clamp and screw, secure water supply line (copper tubing only) to rear panel of freezer as shown. 6. Coil excess water supply line (copper tubing only), about 2½ turns, behind freezer as shown and arrange coils so they do not vibrate or wear against any other surface. 7. Turn ON water supply at shutoff valve and tighten any connections that leak. 8. Reconnect freezer to electrical power source. 9. To turn ice maker on, lower wire signal arm (side mounted) or set the ice maker’s On/Off power switch to the “I” position (rear mounted).
Check with your local building authority for recommendations on water lines and associated materials prior to installing your new freezer. Depending on your local/state building codes, Frigidaire recommends for homes with existing valves its Smart Choice® water line kit 5305513409 (with a 6 ft. Stainless Steel Water Line) and for homes without an existing valve, Frigidaire recommends its Smart Choice® water line kit 5305510264 (with a 20 ft. Copper Water Line with selftapping saddle valve). Please refer to http://frigidaire.stores.yahoo.net for more information.

The mid level and upper level lighting comes on automatically when the door is opened.
IMPORTANT
To disconnect power to the unit, unplug the unit or switch the breaker that supplies power to the unit to the off position. Replace the old bulb with a bulb of the same wattage.
1. To replace the light bulb, turn the temperature control to OFF and unplug the electrical cord. 2. Remove the lens from the lamp housing by unsnapping it from the lamp housing using your fi ngers or a screwdriver. Be careful not to break the locking tabs on the lamp housing. 3. Replace the old bulb with a bulb of the same type and wattage. 4. To replace the lens, snap one side of the lens opening to the tab on the lamp housing. Then carefully attach the other side.
Ice Container
1” or less
IMPORTANT
Your ice maker is shipped with the wire signal arm in the ON position. To ensure proper function of your ice maker, hook up water supply immediately or turn ice maker OFF by lifting the wire signal arm until it clicks and locks in the UP position. Check the leveling bracket on the ice maker to ensure the ice maker is level. If the gap between the freezer wall and the ice maker is the same at top and bottom, then ice maker is level. If the ice maker is not level, loosen the screw and slide the bracket to the correct position to make it level. Retighten the screw. You will need a 1/4 inch socket wrench for this task.
Mid Level Lighting Light Bulb Removal

The upper level lighting comes on automatically when the door is opened.
IMPORTANT
To disconnect power to the unit, unplug the unit or switch the breaker that supplies power to the unit to the off position. Replace the old bulb with a bulb of the same wattage.
1. To replace the light bulb, turn the temperature control to OFF and unplug the electrical cord. 2. Remove the light shield by pushing in on the sides where the two tabs are located in the back, then rotate the light shield down and out. 3. Replace the old bulb with a bulb of the same type and wattage. 4. When replacing the light shield, insert the three tabs in the front of the light shield into the slots in the control box and then rotate the rear upward until the two retaining latches lock into place.
SpaceWise™ Glass Shelves
Multi-position adjustable slide out glass shelves can be moved to any position for larger or smaller packages. The shipping spacers that stabilize the shelves for shipping may be removed and discarded.

The freezer baskets are ideal for large items or items that do not store well on the shelves.
To remove the Mid Level and Tall Lower Basket:
Pull the basket to be removed out until the slide is fully extended. Pull the basket upwards to release the basket from the retaining clips on the basket glides.
This model is equipped with adjustable door bins that can be moved to suit individual needs.
The full width door bin is especially designed to hold large containers or freezer bags. The full width bins are removed in the same manner as the adjustable two liter door bins.

VACATION AND MOVING TIPS
Keep your freezer clean to prevent odor build-up. Wipe up any spills immediately and clean at least twice a year. Never use metallic scouring pads, brushes, abrasive cleaners or strong alkaline solutions on any surface. Do not wash any removable parts in a dishwasher. Always unplug the electrical power.

Part Cleaning Agents Tips and Precautions
Interior & Door Liners
(Stainless Steel Models Only)
Exterior & Handles · Exterior & Handles




Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this freezer.
* Freezer is plugged into a circuit that has a ground fault interrupt. * Temperature control set to “OFF”. * Freezer may not be plugged in, or plug may be loose. * House fuse blown or tripped circuit breaker. * Power outage.
* Use another circuit. If you are unsure about the outlet, have it checked by a certifi ed technician. * See “SETTING THE TEMPERATURE CONTROL” section. * Ensure plug is tightly pushed into outlet.
Freezer does not run.
* Check/replace fuse with a 15 amp time delay fuse. Reset circuit breaker. * Check house lights. Call local Electric Company.
Freezer runs too much or too long.
* Room or outside weather is hot.
* It’s normal for the Freezer to work harder under these conditions. * It takes 24 hours for the Freezer to cool down completely.
* Freezer has recently been disconnected for a period of time. * Large amount of warm or hot food have been stored recently. * Door is opened too frequently or kept open too long. * Door may be slightly open. * Temperature control is set too low.
* Warm food will cause Freezer to run more until the desired temperature is reached. * Warm air entering the Freezer causes it to run more. Open the door less often. * See “DOOR PROBLEMS”. * Set control to a warmer setting. Allow several hours for the temperature to stabilize. * Clean Freezer gaskets (See Care and Cleaning Chart) Worn, cracked or poorly fi tting gaskets should be replaced.
* Freezer gaskets are dirty, worn, cracked or poorly fi tted.
Interior freezer temperature is too cold.
* Temperature control is set too low.
* Set control to a warmer setting. Allow several hours for the temperature to stabilize.
Interior freezer temperature is too warm.
* Temperature control is set too warm. * Door is opened too frequently or kept open too long. * Door may be slightly open. * Large amount of warm or hot food have been stored recently. * Freezer has recently been disconnected for a period of time.
* Set control to a colder setting. Allow several hours for the temperature to stabilize. * Warm air entering the freezer causes it to run more. Open the door less often. * See “DOOR PROBLEMS”. * Wait until the freezer has had a chance to reach its selected temperature. * Freezer requires 24 hours to cool down completely.
“LO” is displayed on control.
* Control has been locked.
* Press the CONTROL LOCK key for three seconds to unlock.
“E7”, “E8”, “E9” is
* The control has registered an error code.
* For toll-free telephone support in the U.S. and Canada: 1-800-374-4432
displayed on control.
“Sb” is displayed on control.
* The control is in Sabbath Mode.
* Pressing the CONTROL LOCK and TEMP MODE keys to exit Sabbath Mode.
Problem Cause Correction · Freezer Operation

Louder sound levels whenever freezer is on.
* Modern freezers have increased storage capacity and more stable temperatures. They require heavy duty compressors.
* This is normal. When the surrounding noise level is low, you might hear the compressor running while it cools the interior.
Louder sound levels when compressor comes on.
* Freezer operates at higher pressures during the start of the ON cycle.
* This is normal. Sound will level off or disappear as freezer continues to run.
Popping or cracking sound when compressor comes on. Bubbling or gurgling sound.
* Metal parts undergo expansion and contraction, as in hot water pipes. * Refrigerant (used to cool freezer is circulating throughout the system.
* This is normal. Sound will level off or disappear as freezer continues to run. * This is normal.
Vibrating or rattling noise.
* Freezer is not level. It rocks on the fl oor when it is moved slightly.
* Level the freezer. Refer to “LEVELING” section.
* Floor is uneven or weak.
* Ensure fl oor can adequately support freezer. Level the freezer by putting wood or metal shims under part of the freezer.
* Freezer is touching the wall.
* Re-level freezer or move freezer slightly. Refer to “LEVELING” in the “FIRST STEPS” section.
Water / Moisture / Frost Inside Freezer
Moisture forms on inside freezer walls.
* Weather is hot and humid, which increases internal rate of frost buildup. * Door is slightly open. * Door is kept open too long.
* This is normal.
* See “DOOR PROBLEMS”. * Open the door less often.
Odors in freezer.
* Interior needs to be cleaned.
* Clean interior with sponge, warm water, and baking soda. Replace air fi lter. * Cover the food tightly.
* Foods with strong odors are in the freezer.
Door will not close.
* Freezer is not level. It rocks on the fl oor when it is moved slightly. * Floor is uneven or weak.
* This condition can force the cabinet out of square and misalign the door. Refer to “LEVELING” section. * Ensure fl oor can adequately support freezer. Level the freezer by putting wood or metal shims under part of the freezer.
Light bulb is not on.
* The light bulb is burned out. * No electric current is reaching the freezer. * Control is in Sabbath mode (Sb is displayed on control)
* Follow directions under “INTERIOR LIGHTING” section. * See “Freezer DOES NOT RUN”.
* Depress TEMP MODE key and CONTROL LOCK key for 3 seconds.

Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Freezer Operation | p.20 | ||
| Freezer does not run. | * Freezer is plugged into a circuit that has a ground fault interrupt. * Temperature control set to “OFF”. * Freezer may not be plugged in, or plug may be loose. * House fuse blown or tripped circuit breaker. * Power outage. | * Use another circuit. If you are unsure about the outlet, have it checked by a certifi ed technician. * See “SETTING THE TEMPERATURE CONTROL” section. * Ensure plug is tightly pushed into outlet. * Check/replace fuse with a 15 amp time delay fuse. Reset circuit breaker. * Check house lights. Call local Electric Company. | p.20 |
| Freezer runs too much or too long. | * Room or outside weather is hot. * Freezer has recently been disconnected for a period of time. * Large amount of warm or hot food have been stored recently. * Door is opened too frequently or kept open too long. * Door may be slightly open. * Temperature control is set too low. * Freezer gaskets are dirty, worn, cracked or poorly fi tted. | * It’s normal for the Freezer to work harder under these conditions. * It takes 24 hours for the Freezer to cool down completely. * Warm food will cause Freezer to run more until the desired temperature is reached. * Warm air entering the Freezer causes it to run more. Open the door less often. * See “DOOR PROBLEMS”. * Set control to a warmer setting. Allow several hours for the temperature to stabilize. * Clean Freezer gaskets (See Care and Cleaning Chart) Worn, cracked or poorly fi tting gaskets should be replaced. | p.20 |
| Interior freezer temperature is too cold. | * Temperature control is set too low. | * Set control to a warmer setting. Allow several hours for the temperature to stabilize. | p.20 |
| Interior freezer temperature is too warm. | * Temperature control is set too warm. * Door is opened too frequently or kept open too long. * Door may be slightly open. * Large amount of warm or hot food have been stored recently. * Freezer has recently been disconnected for a period of time. | * Set control to a colder setting. Allow several hours for the temperature to stabilize. * Warm air entering the freezer causes it to run more. Open the door less often. * See “DOOR PROBLEMS”. * Wait until the freezer has had a chance to reach its selected temperature. * Freezer requires 24 hours to cool down completely. | p.20 |
| “LO” is displayed on control. | * Control has been locked. | * Press the CONTROL LOCK key for three seconds to unlock. | p.20 |
| “E7”, “E8”, “E9” is displayed on control. | * The control has registered an error code. | * For toll-free telephone support in the U.S. and Canada: 1-800-374-4432 | p.20 |
| “Sb” is displayed on control. | * The control is in Sabbath Mode. | * Pressing the CONTROL LOCK and TEMP MODE keys to exit Sabbath Mode. | p.20 |
| Sound And Noise | p.21 | ||
| Louder sound levels whenever freezer is on. | * Modern freezers have increased storage capacity and more stable temperatures. They require heavy duty compressors. | * This is normal. When the surrounding noise level is low, you might hear the compressor running while it cools the interior. | p.21 |
| Louder sound levels when compressor comes on. | * Freezer operates at higher pressures during the start of the ON cycle. | * This is normal. Sound will level off or disappear as freezer continues to run. | p.21 |
| Popping or cracking sound when compressor comes on. Bubbling or gurgling sound. | * Metal parts undergo expansion and contraction, as in hot water pipes. * Refrigerant (used to cool freezer is circulating throughout the system. | * This is normal. Sound will level off or disappear as freezer continues to run. * This is normal. | p.21 |
| Vibrating or rattling noise. | * Freezer is not level. It rocks on the fl oor when it is moved slightly. | * Level the freezer. Refer to “LEVELING” section. | p.21 |
| Vibrating or rattling noise. | * Floor is uneven or weak. | * Ensure fl oor can adequately support freezer. Level the freezer by putting wood or metal shims under part of the freezer. | p.21 |
| Vibrating or rattling noise. | * Freezer is touching the wall. | * Re-level freezer or move freezer slightly. Refer to “LEVELING” in the “FIRST STEPS” section. | p.21 |
| Water / Moisture / Fr | st Inside Freezer | p.21 | |
| Moisture forms on inside freezer walls. | * Weather is hot and humid, which increases internal rate of frost buildup. * Door is slightly open. * Door is kept open too long. | * This is normal. * See “DOOR PROBLEMS”. * Open the door less often. | p.21 |
| Odor In Freezer | p.21 | ||
| Odors in freezer. | * Interior needs to be cleaned. * Foods with strong odors are in the freezer. | * Clean interior with sponge, warm water, and baking soda. Replace air fi lter. * Cover the food tightly. | p.21 |
| Door Problems | p.21 | ||
| Door will not close. | * Freezer is not level. It rocks on the fl oor when it is moved slightly. * Floor is uneven or weak. | * This condition can force the cabinet out of square and misalign the door. Refer to “LEVELING” section. * Ensure fl oor can adequately support freezer. Level the freezer by putting wood or metal shims under part of the freezer. | p.21 |
| Lighting Problems | p.21 | ||
| Light bulb is not on. | * The light bulb is burned out. * No electric current is reaching the freezer. * Control is in Sabbath mode (Sb is displayed on control) | * Follow directions under “INTERIOR LIGHTING” section. * See “Freezer DOES NOT RUN”. * Depress TEMP MODE key and CONTROL LOCK key for 3 seconds. | p.21 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.