SERIES HOODS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a quali- fied person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and stan- dards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori- ties. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. To reduce the risk of fire or electric shock, do not use this range hood with an additional speed control device. 7. Ducted fans must always be vented to the outdoors. 8. To reduce the risk of fire, use only metal ductwork. 9. Use with approved cord-connection kit only. 10. This unit must be grounded. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ig- nite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when cooking flaming foods. 3. Clean ventilating fans frequently. Grease should not be al- lowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PRE- VENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you al-
ready know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
INSTALLER: Leave This Manual With Homeowner. HOMEOWNER: Use and Care Information on Page 5.


❏Drill, electric or ratchet drive
❏1/8" Drill bit for drilling pilot holes
❏1-1/4" wood bit for drilling electrical wiring access hole
❏One straight blade and one phillips head screwdriver

❏Pencil and ruler and/or tape measure
❏Saber saw or keyhole saw for cutting 1" x 2" wood strips to
length and cutting wall or cabinet openings
❏Caulking, metal snips, duct tape, duct (with elbows and tran-
sition, if necessary) and roof or wall cap, as required
❏Electrical wiring and supplies of type to comply with local
The following materials are required only for installations on recessed bottom kitchen cabinets:r Ducted
ROOF CAP

❏Two 1" x 2" x 12" (approximate length) wood strips (pur-
❏Four 1-1/4" long flat head wood screws (purchase locally)
PLANNING DUCTWORK INSTALLATION
(This section for F30WV hoods only. F30WR and F24WR hoods skip this section and go on to “Prepare the Hood”. )
Begin planning ductwork by deciding where the duct will run between the range hood and the outside. For best performance, use the shortest possible duct run and a minimum number of elbows. There are several choices shown - FIGS. A - F below.

FIG. A. Ducting directly through the wall (for range hoods mounted on an exterior wall). Shown are two ways to duct through an outside wall. If a wall cap is used directly off the back of the hood, special care must be taken to make sure that the damper in the damper/duct connector on the hood and damper in the wall cap do not interfere with each other when the hood is operating. This could result in either inadequate air delivery or backdrafts. If this condition does exist, remove the hood damper flap. Sometimes when using a wall cap it is easier to duct vertically and then use an elbow as shown in FIG. B.
3-1/4" X 10" TO 6" ROUND DUCT TRANSITION

FIG. E
In more complex ducting situations, a 3-1/4" x 10" rec- tangular ducting range hood (F30WV hood) can be converted to a round duct by means of a transition.
FIG. C. Ducting straight up through the roof using 3-1/4" x 10" rectangular duct (for single story installations - F30WV hood only).
FIG. D. Ducting between the ceiling joists (for multi-story instal- lations) or through the soffit space above the cabinets (where the soffit connects to an outside wall).
FIG. E. Straight up through the roof using 6" round duct (for single-story installations).
❏Pliers · codes · chase locally)


WIRING BOX COVER DUCTFREE FILTER (F24WR & F30WR HOOD ONLY)
SLOTS

Omit STEP 1 if hood will be installed under cabinets with flush bottom.

a.) Electrical wiring opening in wall or cabinet.
b.) Duct opening in wall or cabinet (F30WV hood ONLY).



(This section for F30WV hoods only. F24WR and F30WR hoods skip this section and go on to “Install Range Hood”. )
NOTE These instructions will follow plans made on Page 2. Start at the exterior and run ductwork back to the range hood. For best possible performance, use the shortest possible duct run and a minimum number of elbows. Do not vent a range hood into an attic space. A buildup of grease in the attic could become a fire hazard. Use only metal ductwork. DO NOT USE PLASTIC DUCT. As- semble duct run securely so that in case of a grease fire on the range, the fire will be contained inside metal ductwork. Tape all duct connections.
CENTER LINE
HOOD WIDTH
**10-15/16" FOR 24" RANGE HOOD, 13-15/16" FOR 30" RANGE HOOD

a.) Wall Cap Discharge; (FIG. 7) Use saber saw or keyhole saw to
cut hole slightly larger than duct size used so that duct will line up easily with damper/duct conector on hood. Install casing strips if cap will be installed on siding. Attach required amount of duct to wall cap and run duct back to hood. Fasten cap to wall and caulk well.
b.) Roof Cap Discharge; (FIG. 8) Cut a hole in roof slightly larger
than duct size being used. Run ductwork down to hood location. Leave 3/4" of duct projecting above roof surface on high side.
Trim duct parallel to roof pitch and seal all around duct with roof cement.
Carefully trim shingles and slide back of roof sheet under shingles. Nail roof sheet to roof under shingles at top two corners and two sides. Nail sheet directly to roof in four places at bottom.

Using roof cement, seal all nail heads and shingles which were cut or lifted. Do not seal bottom edge of roof sheet.
CENTER LINE
INSTALL RANGE HOOD

(FIG. 10) c.) Damper/duct connector slides into ductwork.
(F30WV hoods only) 3. Adjust hood so that hood front is flush with cabinet frame. 4. Tighten hood mounting screws firmly. 5. Fasten wiring to hood with proper electrical connector for type of wire being used.

DUCT
6. Strip 1/2" of insulation from wires. Connect white to white, black to black, and green to prepared hole with green ground screw pro- vided. (FIG. 11) 7. Replace wiring box cover and screw. Make sure that all wiring is safely contained inside. 8. Install light (75 Watt maximum). For easier installation, squeeze plas- tic lens and remove it from hood. Remember to reinstall lens. (FIG.12) 9. Turn on power and check operation of fan and light. Make sure that damper operates freely.
CABINET


SWITCHES The fan and light are each controlled by a rocker switch. The light switch has two positions, “ON” and “OFF”. The fan switch has three positions - “HIGH”, “LOW” and “OFF”. ( “OFF” is the middle position.)

FILTERS F30WV Hood Only: Remove aluminum filter by turning filter retainer to one side. (FIG. 13) Filter should be washed once a month in a hot deter- gent solution. Aluminum filters are dishwasher safe. When in- stalling filter, make sure that filter slides under retaining tabs on back of fan housing. Turn filter retainer so that arrows on re- tainer point toward front and back of hood. F24WR & F30WR Hoods Only: The F24WR AND F30WR hoods are equipped with a ductfree filter. Remove filter by turning filter retainer to one side. (FIG. 13) The ductfree filter is not washable, and will last up to twelve months with normal use. Replace the filter when colored side becomes noticeably dirty or discolored. When installing filter, make sure that filter slides under retain- ing tabs on back of fan housing. MAKE SURE THAT COLORED SIDE OF FILTER IS NEXT TO FAN WHEN FILTER IS IN- STALLED. Turn filter retainer so that arrows on retainer point toward front and back of hood.


WARNING ALWAYS DISCONNECT ELECTRIC POWER BEFORE
SERVICING RANGE HOOD.
FAN ASSEMBLY Remove filter. Remove two screws holding motor bracket to range hood, and unplug fan assembly. Be careful not to allow fan assembly to drop when screws are removed. (FIG. 14)
GROUND WIRE (BARE OR GREEN WIRE) GROUNDING BRACKET STAR LOCKNUT
CLEANING Clean your hood with a mild detergent suitable for painted sur- faces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS OR SCOURING POWDERS. Fan assembly may be vacuumed. Fan assembly is permanently lubricated, and never needs oiling.

SOCKET
HOW TO AVOID A COMMON RANGE-TOP GREASE FIRE



SERVICE PARTS
F30WV SERIES 3-1/4" X 10" DUCTED HOOD
KEY NO. DESCRIPTION
1 Outlet Box Cover 2 #8 x 3/8 Sheet Metal Screw* 3 Bulb Holder with Wires 4 Light Lens 5 Screw/Nut Kit (Includes 2 - #10-16 x .500

screws and 2 - #10-16 sheet metal nuts) 6 Fan Blade 7 #6-32 Locking Nuts* (2 Required) 8 Motor Mounting Bracket 9 Motor Assembly (Includes Key Nos. 6, 7, & 8) 10 Aluminum Filter 11 Filter Retainer 12 #8B x 1/4 Hex Head Sheet Metal Screws*
(2 Required) 13 Damper Flap 14 Damper Bushing 15 Damper Assembly
(Includes Key Nos. 13, 14 and 21) 16 Nameplate - Black Nameplate - White 17 2-Speed Motor Switch - Black 2-Speed Motor Switch - White 18 Light Switch - Black Light Switch - White 19 Motor Receptacle with Wires 20 #10-32 x 1/2 Green Ground Screw* 21 Damper Bumper ** Light Bulb, 75 Watt (not included)*
Order service parts by "KEY NO." * Standard Hardware. May be purchased locally. ** Not Illustrated.

F30WR & F24WR SERIES NON-DUCTED HOOD

1 Outlet Box Cover 2 #8 x 3/8 Sheet Metal Screw* 3 Bulb Holder with Wires 4 Light Lens 5 Screw/Nut Kit (Includes 2 - #10-16 x .500
screws and 2 - #10-16 sheet metal nuts) 6 Fan Blade 7 #6-32 Locking Nuts* (2 Required) 8 Motor Mounting Bracket 9 Motor Assembly
(Includes Key Nos. 6, 7, & 8) 10 Ductfree Filter 11 Filter Retainer 12 Nameplate - Black Nameplate - White Nameplate - Bisque 13 2-Speed Motor Switch - Black 2-Speed Motor Switch - White 2-Speed Motor Switch - Bisque 14 Light Switch - Black Light Switch - White Light Switch - Bisque 15 Motor Receptacle with Wires 16 #10-32 x 1/2 Green Ground Screw* 17 Grommet ** Light Bulb, 75 Watt (not included)*
Order service parts by "KEY NO." * Standard Hardware. May be purchased locally. ** Not Illustrated.

Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.
This warranty does not cover the following:
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
If You Need Service
Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below.
This warranty only applies in the USA and Canada. In the USA, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed by Electrolux or an authorized service company. Product features or specifications as described or illustrated are subject to change without notice.
USA 1.800.944.9044 Electrolux Major Appliances North America P.O. Box 212378 Augusta, GA 30907
Canada 1.800.668.4606 Electrolux Canada Corp.
5855 Terry Fox Way Mississauga, Ontario, Canada
99043804A
Exclusions
Owners and our team usually reply within a day — and your question helps the next person too.