F30WC, F36WC, & F42WC SERIES 4-WAY CONVERTIBLE RANGE HOOD READ AND SAVE THESE INSTRUCTIONS
a) Purchase non-ducted filter separately. b) Remove and discard damper/duct connector and louver cover
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
(See Step 4) in “Prepare the Hood,” Page 2. c) Follow all steps except steps inside dotted lines. For Ducted Installation:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PRE- VENT BURNS. If the flames do not go out immediately, EVACU- ATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you
Follow all steps, including steps inside dotted lines.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING:
already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at ser- vice panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhaust- ing of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au- thorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this unit with any solid-state speed control de- vice. 8. To reduce the risk of fire, use only metal ductwork. 9. Use with approved cord-connection kit only. 10. This unit must be grounded. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when cooking flaming foods. 3. Clean ventilation fans frequently. Grease should not be al- lowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/ or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 4. For best capture of cooking impurities, your range hood should be mounted 18-24" above the cooking surface. 5. Please read specification label on product for further information and requirements.
the Homeowner.
Information on Page 5.


TOOLS ❏ Drill, electric or ratchet drive ❏ 1-1/4" Spade bit ❏ Common head and phillips head screwdriver ❏ Pliers ❏ Tape measure or ruler and pencil For Ducted Installations ONLY: ❏ Saber saw or drywall saw ❏ Metal snips MATERIALS ❏ Electrical wiring and supplies of type to comply with local codesFor Ducted Installations Only: ❏ Roof or wall cap ❏ Roof cement or caulk ❏ Duct and duct tape For Installation on Kitchen Cabinets with Recessed Bottoms Only: ❏ Two 1" x 2" x 12" (approximate length) wood strips (pur- chase locally) ❏ Four 1-1/4" long flat head wood screws (purchase locally) to fasten strips to cabinet bottom
FIG. 1B

3-1/4" x 10" DUCT

3-1/4" x 10" DUCT
PLANNING DUCTWORK INSTALLATION
ADJUSTABLE ELBOW

Begin planning ductwork by deciding where the duct will run between the range hood and the outside. For best performance, use the shortest possible duct run and a minimum number of elbows. There are several choices shown - FIGS. 1A - 1E.
6" ROUND DUCT 3-1/4" x 10" TO 6" ROUND DUCT TRANSITION
In more complex ducting situations, a 3-1/4" rectangular ducting range hood can be converted to a round duct by means of a transition.
FIG. 1A. Ducting directly through the wall (for range hoods mounted on an exterior wall). Shown are two ways to duct through an outside wall. If a wall cap is used directly off the back of the hood, special care must be taken to make sure that the damper in the damper/duct connector on the hood and damper in the wall cap do not interfere with each other when the hood is oper- ating. This could result in either inadequate air delivery or back drafts. If this condition does exist, remove the hood damper flap. Sometimes when using a wall cap it is easier to duct vertically and then use an elbow as shown in FIG. 1B.
ROOF CAP

3-1/4" x 10" TO 6" ROUND DUCT TRANSITION
FIG. 1C. Ducting straight up through the roof using 3-1/4" x 10" rectangular duct. (For single story installations.)
FIG. 1D. Ducting between the ceiling joists (for multi-story instal- lations) or through the soffit space above the cabinets (where the soffit connects to an outside wall).
FIG. 1E. Straight up through the roof using 3-1/4” x 10” to 6” round duct transition and 6" round duct (for single-story installa- tions).
FIG. 1F. Straight up through the roof using 7" round duct (for single-story installations). Requires optional damper Model Damp Kit available from your local dealer.

DAMPER
MODEL “DAMPKIT”


For Ductfree Installations Only:

for hood to function in ductfree mode. 5. Remove either top or rear electrical knockout depending upon whether wiring will enter hood from wall or cabinet. (FIG. 4) DUCTED INSTALLATION ONLY
function in ducted mode. 6. Remove appropriate duct knockout on hood by inserting screwdriver into edge of knockout and breaking tabs holding knockout to hood. You may have to tap screwdriver with ham- mer to break tabs. Peel knockout back with pliers. (FIG. 5) 7. Fit damper/duct connector over opening and secure in place with black sheet metal screws. (FIG. 6) Hinge pins and damper/duct connector should be toward top of hood for ducting through wall or toward back of hood for ducting through cabinet above hood. Seal joint between damper/duct connector and hood with duct tape. 8. 7” round ducted discharge only: Re-install 7” round duct plate removed in Step #2 under “PREPARING THE RANGE HOOD” section. For best performance, line up the 7” round duct plate with the 7” round opening on hood. Mount duct plate to hood with 2 screws from duct plate and 2 screws from 3¼” x 10” damper. Install a 7” round damper (purchase separately). Damper flap must open freely in direction of air flow (away from range hood).



NOTE MOUNT HOOD SO THAT BOTTOM OF HOOD IS 18"-24" ABOVE COOKING SURFACE. TOP FRONT EDGE OF HOOD SHOULD BE FLUSH WITH FRONT OF CABINET FRAME. IF DISTANCE BETWEEN WALL AND FRONT OF CABINET FRAME IS MORE THAN 12" THERE WILL BE A SPACE BE- TWEEN BACK OF HOOD AND WALL. THIS IS NORMAL. OMIT STEP 9 if range hood will be installed under cabinets with flush bottom.

9. (For installation on recessed bottom cabinets only) Attach a wood filler strip at each side of recessed area under cabi- net. (Use two 1" x 2" strips cut to length.) If recess is more than 1" use thicker strips. Attach strips with 1-1/4" screws about 3" from each end. See FIG. 7. 10.Measure and mark the following (FIGS. 7 & 8): a) Electrical line opening b) Duct opening 11.Drill four pilot holes in corners of marked duct opening as shown and cut opening with saber saw or keyhole saw. 12.Use 1-1/4" drill bit to drill opening for electrical connection in wall or cabinet. 13.Hold hood up against cabinet bottom and trace keyhole slots onto cabinet bottom of filler strips. 14.Screw the four supplied 7/8" wood screws for mounting the hood into the exact center of the narrow end of the keyhole slots marked underneath the cabinet. Allow 3/8" of the screws to project, so the hood can be fitted into place.



3-1/4” x 10” DUCT
NOTE THESE INSTRUCTIONS WILL FOLLOW THE PLANS MADE ON PAGE 2. START AT THE EXTERIOR AND RUN THE DUCT BACK TO THE RANGE HOOD. FOR BEST PERFORMANCE OF YOUR RANGE HOOD, USE THE SHORTEST POSSIBLE DUCT RUN AND A MINI- MUM NUMBER OF ELBOWS. NEVER VENT A RANGE HOOD INTO AN ATTIC SPACE BECAUSE A BUILDUP OF GREASE WILL BECOME A FIRE HAZARD. USE ONLY METAL DUCTWORK (DO NOT USE PLASTIC DUCT). ASSEMBLE SECURELY SO THAT IN CASE OF A GREASE FIRE ON THE RANGE, THE FIRE WILL BE CON- TAINED INSIDE METAL DUCT WORK. IT IS A GOOD PRACTICE TO TAPE ALL DUCT CONNEC- TIONS, MAKING THEM BOTH SECURE AND AIR TIGHT.

CABINET BOTTOM
BACK WALL
VERTICAL DUCTING AND WIRING
15.Follow appropriate directions below for type of duct work you are installing:
Use a saber saw to cut a hole slightly larger than duct so duct will line up easily with hood. Install casing strips on outside walls finished in siding. Assemble the duct work and tape all joints. Run duct work back to hood. Fasten wall cap to last section of duct and nail or screw cap to wall. Seal all around flange on wall cap with caulking compound. Make sure that enough duct runs into the room so that the duct will overlap the damper/duct connector by 3/4" when the hood is installed.
CABINET FRONT / FRENTE DEL GABINETE
CABINET BOTTOM FONDO DEL GABINETE 7½"
8" DIA. ACCESS HOLE ORIFICIO DE ACCESO
8" DE DIÁ.
ROOF CAPS Cut hole in roof slightly larger than duct so duct will line up easily with hood. Trim shingles around hole so that they will fit snugly around hood of cap when cap is installed. Assemble the duct work and tape all joints. Run the duct work down to hood. Trim duct parallel to roof pitch, leaving 3/4" of duct projecting above roof. Seal all around duct with roof cement. Install roof cap, inserting back edge of cap under shingles. Seal around cap with roof cement and seal all nail heads and shingles which were cut or lifted. Make sure that enough duct runs into the room so that the duct will overlap the damper/duct connector by 3/4" when the hood is put into place.
WOOD SHIMS (recessed-bottom cabinets only)
(in cabinet bottom) ORIFICIO DE ACCESO PARA
CUÑAS DE MADERA (sólo gabinetes de fondo empotrado)
(en el fondo del gabinete)
ROOF CAP




16.Bring electrical cable through access hole drilled in wall or bottom of cabinet. Provide 6" wire leads and install proper connector for type of cable being used. Remove lock nut from connector and let prepared cable project through cabi- net or wall opening so it is ready for installation into range hood. (FIG. 10) 17.Position hood in place so that: a) Electrical line is routed through appropriate knockout open-
ELECTRICAL LINE FIG. 11

ing. This step will have to be accomplished while position- ing hood. (FIG. 13) b) Large part of keyhole mounting slots on hood fit onto
hood mounting screws projecting from bottom of cabi- net. (FIG. 11) c) Damper/duct connector slides into duct work in wall or
cabinet.

GREEN GROUND SCREW
GROUND WIRE (BARE OR GREEN WIRE)
STAR LOCKNUT GROUNDING BRACKET
USE AND CARE
FIG. 13

SWITCHES Right knob controls light. Left knob controls blower. Rotate knob CLOCKWISE to turn blower ON to HIGH speed. Further CLOCKWISE rotation de- creases blower speed. Rotate knob fully COUNTERCLOCK- WISE (past HIGH speed) to turn fan OFF. CLEANING Finish Keep your range hood clean using a mild detergent suit- able for painted surfaces. Aluminum Filters should be cleaned frequently with a deter- gent solution to avoid grease build up. They are also dishwasher safe.
NON-DUCTED FILTER (SOLD SEPARATELY)
FIG. 14

FILTER REMOVAL Filters are removed by turning filter clip to the side and lifting filter or filters out. In ducted version, turn filter retaining clip to one side and place aluminum filter under embossed retaining tabs on back of fan housing. Turn filter clip so that the low end of clip holds single filter firmly in place. (FIG. 13) In ductfree version, place both aluminum and ductfree filter un- der tabs on back of fan housing. Turn filter retaining clip so that high end holds both filters firmly in place. Make sure ductfree filter is next to fan assembly, with blue side next to fan blade, and aluminum filter is facing out. NOTE: Make sure that arrows on filter retaining clip point to- ward back and front of hood. LIGHT BULB REPLACEMENT Light bulb (not supplied with hood) should be 75 watts maxi- mum. The lens covering bulb is removed by pressing the two extending tabs together until they release from the retaining slots. (FIG. 14) FAN ASSEMBLY REMOVAL Be sure power is disconnected. Remove filters. Remove the two screws holding the motor bracket to the range hood and unplug the fan assembly. Be careful not to allow fan assembly to drop when the screws are removed. (FIG. 15).
FIG. 15


F30WC, F36WC, & F42WC SERIES RANGE HOOD

1 Outlet Box Cover 2 #8 x 3/8 Sheet Metal Screw* 3 Bulb Holder with Wires 4 Light Lens 5 Screw/Nut Kit (Includes 2 - #10-16 x .500 screws and 2 - #10-16 sheet metal nuts) 6 Fan Blade 7 #6-32 Locking Nuts* (2 Required) 8 Motor Mounting Bracket 9 Motor Assembly (Includes Key Nos. 6, 7, and 8) 10 Aluminum Filter Non-Ducted Filter (purchase separately) 11 Filter Retainer 12 #8B x 1/4 Hex Head Sheet Metal Screws* (2 Req) 13 Damper Flap 14 Damper Bushing 15 Damper Assembly (Includes Key Nos. 13 and 14) 16 Nameplate (Black) Nameplate (White) Nameplate (Biscuit) 17 2-Speed Motor Switch (Black) 2-Speed Motor Switch (White) 2-Speed Motor Switch (Biscuit) 18 Light Switch (Black) Light Switch (White) Light Switch (Biscuit) 19 Motor Receptacle with Wires 20 Louver Cover (Black) Louver Cover (White) Louver Cover (Biscuit) 21 7” Round Duct Plate
Order service parts by “KEY NO.” * Standard Hardware. May be purchased locally.



Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.
This warranty does not cover the following:
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
If You Need Service
Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below.
This warranty only applies in the USA and Canada. In the USA, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed by Electrolux or an authorized service company. Product features or specifications as described or illustrated are subject to change without notice.
USA 1.800.944.9044 Electrolux Major Appliances North America P.O. Box 212378 Augusta, GA 30907
Canada 1.800.668.4606 Electrolux Canada Corp.
5855 Terry Fox Way Mississauga, Ontario, Canada
99043806A
Exclusions
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.