2. (F31) Check resistance at room temperature, if less than 500 ohms, replace RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector. If resistance is correct replace the EOC. F31

F30 1. (F30) Check resistance at room temperature & compare to RTD Sensor resistance chart. If resistance is correct replace the EOC. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring

F10 1. Check Oven Sensor Probe using the RTD scale found in the tech sheet. Replace if defective. 2. If oven is overheating disconnect power from the range and unplug connector P1 from power supply board 1. Reapply power to the range. If oven continues to heat when the power is reapplied, replace the EOC.

3. If motor runs with test cord check continuity of wire harness to lock motor terminals. If harness is good replace the EOC.
1. Test continuity of lock motor windings. Replace lock motor assembly if windings are open. 2. Test lock motor operation by using a test cord to apply voltage. If motor does not operate replace lock motor assy.
1. Test continuity of wiring between EOC and lock switch on lock motor assy. Repair if needed. 2. Advance motor until cam depresses the plunger on lock motor switch. Test continuity of switch contacts. If switch is open replace lock motor assy.

F60 1. Verify proper assembly of backguard panel. Check for damaged or loose panels, brackets, endcaps, etc. 2. Check for blocked ventilation slots in control panel rear cover. 3. Inspect oven vent for proper assembly and air flow. 4. Verify operation of cooling fan (if present)

Fault CodeLikely Failure Condition/ CauseSuggested Corrective Action F10Runaway Temperature. Oven heats when no cook cycle is programmed.1. Check Oven Sensor Probe using the RTD scale found in the tech sheet. Replace if defective. 2. If oven is overheating disconnect power from the range and unplug connector P1 from power supply board 1. Reapply power to the range. If oven continues to heat when the power is reapplied, replace the EOC. NOTE: Severe overheating may require the entire oven to be replaced should damage be extensive. F11Shorted Keypad or Selector Switch1. Reset power supply to range - Disconnect power, wait 30 seconds and reapply power. 2. Check/reseat ribbon harness connections. 3. Replace the EOC. F12 F13EOC Internal software error or failureDisconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC. F15EOC Internal hardware error of failureDisconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC. F16 F17 F18EOC Internal software error of failureDisconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC. F30 F31Open oven sensor probe circuit. Shorted oven sensor probe circuit.1. (F30) Check resistance at room temperature & compare to RTD Sensor resistance chart. If resistance is correct replace the EOC. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector. 2. (F31) Check resistance at room temperature, if less than 500 ohms, replace RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector. If resistance is correct replace the EOC. F60Electronic Oven Control (EOC) over temperature. Higher than normal temperature detected on1. Verify proper assembly of backguard panel. Check for damaged or loose panels, brackets, endcaps, etc. 2. Check for blocked ventilation slots in control panel rear cover. 3. Inspect oven vent for proper assembly and air flow. 4. Verify operation of cooling fan (if present) F90 F91 F92 F93 F94 F95the EOC circuit board Door lock motor or latch circuit failureIf lock motor runs: 1. Test continuity of wiring between EOC and lock switch on lock motor assy. Repair if needed. 2. Advance motor until cam depresses the plunger on lock motor switch. Test continuity of switch contacts. If switch is open replace lock motor assy. 3. If motor runs and switch contacts and wiring harness test good, replace the EOC. If lock motor does not run: 1. Test continuity of lock motor windings. Replace lock motor assembly if windings are open. 2. Test lock motor operation by using a test cord to apply voltage. If motor does not operate replace lock motor assy. 3. If motor runs with test cord check continuity of wire harness to lock motor terminals. If harness is good replace the EOC. LinE ERREOC Internal voltage test error or failureDisconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC.

F13 Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC.

error of failure F15 Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC.

Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC.

ERR Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC. EOC Internal voltage test

Selector Switch F11 1. Reset power supply to range - Disconnect power, wait 30 seconds and reapply power. 2. Check/reseat ribbon harness connections. 3. Replace the EOC.

3. If motor runs and switch contacts and wiring harness test good, replace the EOC. If lock motor does not run:

Cause Suggested Corrective Action

harness between EOC & Sensor Probe connector.

Electonic Oven Control Fault Code Descriptions

If lock motor runs:

Likely Failure Condition/

Oven heats when no cook

Open oven sensor probe

(EOC) over temperature.

Runaway Temperature.

Door lock motor or latch

cycle is programmed.

the EOC circuit board

error or failure F12

error of failure F16

probe circuit.

circuit.

Code

Fault

F17

F18

F90

F91

F92

F93

F94

F95

  • All uninsulated electrical terminals, connectors, heaters, etc. are adequately spaced away from all metal parts and panels.
  • All safety grounds (both internal and external) are correctly and securely reassembled.
4. Press the Self-clean key pad to change the sign of the adjustment to a (-)

Set the electronic oven control for normal baking at 350°F. Obtain an average

3. Use the number key pads (0-9) to enter the desired amount of adjustment

oven temperature after a minimum of 5 cycles. Press Cancel keypad to end

2. The current calibration offset (temperature adjustment) should appear in
5. Once the desired adjustment (-35° to 35° F) has been entered, press the

Start key pad to accept the change or the Cancel key pad to reject the

1. While in a non-cooking mode, press and hold the Bake key pad for 6

if necessary. A positive adjustment will not display a sign.

will not change the self-cleaning temperature.

Temperature Adjustment

the temperature display.

Gas Range with ES 540 Electronic Oven Control

SERVICE DATA SHEET

Oven Calibration

(up to 35°F).

seconds.

change.

Circuit Analysis Matrix

Bake mode.

Electronic Oven Control & Jumper Connections (EOC Rear View)

of these subjects generally considered acceptable in the appliance

having electrical and mechanical training and a level of knowledge

GREEN or GREEN WITH YELLOW STRIPES. Ground leads are not

NOTICE - This service data sheet is intended for use by persons

assume any liability for injury or damage of any kind arising from

3. GROUNDING: The standard color coding for safety ground wires is

grounds prior to completion of service. Failure to do so will

1. Before servicing or moving an appliance remove power cord from

important that the service technician reestablish all safety

  • All electric connections are correct and secure.
  • All electrical leads are properly dressed and secured away from sharp edges, high-temperature components, and moving parts.

To avoid the possibility of personal injury and/or property damage, it is

2. Never interfere with the proper installation of any safety device.

repair trade. The manufacturer cannot be responsible, nor

to be used as current carrying conductors. It is extremely

electrical outlet, trip circuit breaker to OFF, or remove fuse.

4. Prior to returning the product to service, ensure that:

OR DESTROY THE CONTENTS

REPLACE CONTENTS IN BAG

examples, but without limitation, of such practices.

DO NOT REMOVE THIS BAG

WIRING DIAGRAMS AND SERVICE

INFORMATION ENCLOSED

IMPORTANT

create a potential safety hazard.

p/n 316905002 (0906) En

SAFE SERVICING PRACTICES

the use of this data sheet.

Show 11 more labels / short text on this page
temperature detected on · EOC Internal hardware · Electronic Oven Control · EOC Internal software · EOC Internal software · Shorted oven sensor · Shorted Keypad or · Higher than normal · error or failure · circuit failure · LinE
Page 2 of the Frigidaire ES 540 user manual — General Troubleshooting Diagram General Troubleshooting Schematic
Page 2 · click to enlarge
Page 2
Frigidaire ES 540 — General Troubleshooting Diagram General Troubleshooting Schematic diagram (page 2)
Fig. 1 · General Troubleshooting Diagram General Troubleshoot…

General Troubleshooting Diagram General Troubleshooting Schematic

Page 4 of the Frigidaire ES 540 user manual — Schéma de dépannage général Schéma de dépannage général
Page 4 · click to enlarge
Page 4
Frigidaire ES 540 — Schéma de dépannage général Schéma de dépannage général diagram (page 4)
Fig. 2 · Schéma de dépannage général Schéma de dépannage géné…

Schéma de dépannage général Schéma de dépannage général

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
F12 F13F12 F13Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC. p.1
F16 F17 F18F16 F17 F18Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC. p.1
F30 F31F30 F311. (F30) Check resistance at room temperature & compare to RTD Sensor resistance chart. If resistance is correct replace the EOC. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector. 2. (F31) Check resistance at room temperature, if less than 500 ohms, replace RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector. If resistance is correct replace the EOC. p.1

Ask about the Frigidaire ES 540

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frigidaire ES 540

Be the first to ask — other owners or our team will answer.

Original document

Frigidaire ES 540 manual PDF

4 pages·657 KB·Range·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…