Dehumidifier SERVICE MANUAL

MODELS: DH300EY5/DH305Y5/DH300MY5

LD40Y5/DH400MY5 DH404EY5/DH400EY5/LD40EY5 DH504ELY5/LD50ELY5 LD65ELY5

CAUTION

- BEFORE SERVICING THE UNIT,

READ THE SAFETY PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORIZED SERVICE.

Page 2 of the Frigidaire DH404EY5 user manual — Table of contents
Page 2 · click to enlarge
Page 2

Table of contents

Page 3 of the Frigidaire DH404EY5 user manual — AUTO RESTART
Page 3 · click to enlarge
Page 3

1. PREFACE

This Service Manual provides various service information, including the mechanical and electrical parts. This dehumidifier was manufactured and assembled under the strict quality control procedures. The refrigerant is charged at the factory. Be sure to read the safety precaution prior to servicing the unit.

1.1 SAFETY PRECAUTIONS

  • Disconnect the power supply before servicing or replacing any component.
  • Do not cut off the grounding prong or alter the plug in any manner.

1.2 FEATURES AND DIMENSIONS

  • 1.2.1 FEATURES
  • Quiet operation
  • High efficiency
  • Adjustable humidistat
  • Automatic defrost
  • Automatic shut-off
  • Bucket-full indicator light
  • Easy roll casters
  • Removable & large capacity bucket.
  • Washable air filter
  • Two-speed fan
  • Drain hose connection.
  • Low temperature operation (DH504EL/LD50EL/LD65EL)

1.2.2 DIMENSIONS (mm/in)

385 (15 5 /32 )

340 (13 3 /8 )

Continuous On.

4Hr. On/Off

2Hr. On/Off

AUTO RESTART

HUMIDITY CONTROL BUCKET

FULL

FAN SPEED TIMER

HUMIDITY SETTING

POWER

ENERGY STAR

540 (21 1/4 )

High · Low

Page 4 of the Frigidaire DH404EY5 user manual — 1.4 SPECIFICATIONS
Page 4 · click to enlarge
Page 4

1.3 MODEL NAMES

MODEL NAME CAPACITY (Pints/24hrs)30405065 CONTROL PANELMECHANICAL TYPEDH305Y5, DH300MY5DH400MY5,LD40Y5-- ELECTRONIC TYPEDH300EY5DH404Y5 DH400EY5,LD40EY5DH504ELY5 LD50ELY5LD65ELY5

1.4 SPECIFICATIONS

MODELS ITEMSDH305Y5, DH300MY5 DH300EY5DH400MY5, LD40Y5 DH404EY5 DH400EY5, LD40EY5DH504ELY5* LD50ELY5*LD65ELY5* POWER SUPPLY(Phase,V,Hz)1Ø, 115V,60Hz INPUT(W)480580560850 RUNNING CURRENT(A)4.85.75.48.3 ENERGY FACTOR(L/kw.h)1.231.361.751.50 REFRIGERANTR22 REFRIGERANT CHARGE, oz(g)3.53(100)4.94(140)7.93(225)8.46(240) THERMISTOROPEN33.8°F(1±0.5°C) CLOSE50°F(10±0.5°C) SOLENOID VALVE*--Using Temp/Humid.:-4~122°F(-20~50°C)/95%RH Rating:7W/90mA COMPRESSOR MODEL No.QS064CABQS075CBAQA075CDBQA114CBD PROTECTOROVERLOAD PROTECTOR FOR COMPRESSOR INTERNAL PROTECTOR(FUSE)FOR MOTOR CAPACITOR35µF, 270VAC40µF, 270VAC35µF, 270VAC35µF, 270VAC MOTOR ASSEMBLY,SINGLEShaded pole motor, 72W/1.4A, Thermal cutoff:266°F/130°CShaded pole motor, 91W/1.8A, Thermal cutoff:266°F/130°C SWITCH ASSEMBLY,MICRO15A/250VAC OUTSIDED MENSIONS WxHxD,mm(in)385X540X340(15 5/32 x 21 1/4 x 13 3/8) NET WEIGHT,kg(lbs)17.6(38.9)17.6(38.9)20.4(44.9)22.2(48.9)

*NOTE:Specifications are subject to minor change without notice for further improvement.

Page 5 of the Frigidaire DH404EY5 user manual — SETTING
Page 5 · click to enlarge
Page 5

1.5 CONTROL TYPE

1.5.1 Mechanical type

  • Humidity Control
  • When you first use the dehumidifier, turn the humidity control to 5 or 6. If you still have moisture, turn the humidity control to a higher setting. MAX is the highest setting.
  • When excess moisture and dampness odors are gone, adjust the control to a lower setting. Use the dehumidifier as long as excess moisture is present.

Fan Speed Humidity Control

Fan Speed • The fan control adjusts the fan speed. Set the fan control to HIGH for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to LOW.

  • Auto Shut-Off
  • This light glows when the bucket is full, or when the bucket is removed or not placed in the proper position. In these cases the Water Level Control Switch shuts off the dehumidifier.
  • When the light glows, check the bucket condition.

1.5.2 Electronic type

Bucket Full Indicator • This light glows when the water bucket is full and needs to be emptied.

Constantly On.

4hr. On/Off

HUMIDITY CONTROL BUCKET

2hr. On/Off

FULL

AUTO RESTART

FAN SPEED TIMER

HUMIDITY

POWER

Power • Operation starts when this button is pressed and stops when the button is pressed again.

SETTING

Auto Restart • Once power is restored after a power outage, the unit returns to its previous operation setting after a 2 minute delay. The fan runs immediately when the power is restored.

  • Fan Speed
  • This controls the speed of the airflow.
  • High: Fan speed is set to high.
  • Low: Fan speed is set to low.
  • When Fan Speed button is pressed, the fan speed mode is changed.
  • Humidity Control
  • This button controls the humidity in the room.
  • Press button to raise the humidity setting.
  • Press button to lower the humidity setting.
  • The humidity setting can be set to a permanent "On" setting or to a specific humidity setting between 35% and 70% in 5% increments.
  • "On" setting: Dehumidifier runs continuously regardless of humidity condition.
  • 35% - 70% setting: Dehumidifier runs on and off according to surrounding humidity conditions.
  • Timer
  • Press this button to select type of operation.
  • Select continuous On for uninterrupted operation.
  • Select either 2 or 4 hr. On/Off for cycled operation: The unit will operate for 2 or 4 hours, and then shut off completely for 2 or 4 hours. The cycle repeats until you change the setting.
  • When Timer button is pressed, the Timer indicator lights shift as follow from 2hr.On/Off to 4hr.On/Off.
Show 6 more labels / short text on this page
High · Auto Shut-Off · Low · Off Max · High · Low
Page 6 of the Frigidaire DH404EY5 user manual — 1.6 HOW TO OPERATE DEHUMIDIFIER
Page 6 · click to enlarge
Page 6

1.6 HOW TO OPERATE DEHUMIDIFIER

1.6.1 HOW DOES THE DEHUMIDIFIER WORK? Moist, humid air is drawn over a cold refrigerated dehumidifying coil. Moisture in the air condenses on this coil and drains into a bucket (or through the bucket into a hose and drain). Dry, clean air is drawn over the condenser where it is actually heated several degrees and discharged out the rear grill into the room. (See Figure 4) I It is normal for the surrounding air to become

Frigidaire DH404EY5 — 1.6 HOW TO OPERATE DEHUMIDIFIER diagram (page 6)
Fig. 1

slightly warmer as the dehumidifier operates. This warming effect further reduces the relative humidity of the surrounding air.

1.6.2 LOCATION FOR THE DEHUMIDIFIER Allow at least 12 inches of space on all sides of the unit for good air circulation. (See Figure 5) I The dehumidifier must be operated in an enclosed

Frigidaire DH404EY5 — 1.6 HOW TO OPERATE DEHUMIDIFIER diagram (page 6)
Fig. 2

area to be most effective. I Close all doors, windows and other outside

openings to the room. Place the dehumidifier in a location that does not restrict air flow into the front grille or out the rear grille.

The operation of dehumidifier in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

1.6.3 MICRO SWITCH The micro switch assembly, which is located on the drain pan of inside unit, automatically shuts off the dehumidifier when the bucket is full (note, the Auto Shut Off lights, to indicate bucket must be emptied). The bucket replaces in its place, the unit again turns itself on.

1.6.4 AUTO DEFROST When frost builds up on the cooling coils, the unit will automatically cycle off until the frost disappears. The fan continues to run.

operated in low temperature conditions frost can form in the evaporator coil and the unit will cycle ON/OFF repeatedly. In this case, please check your room temperature conditions and stop the unit.

a temperature of 42°F(6°C).

Page 7 of the Frigidaire DH404EY5 user manual — SETTING
Page 7 · click to enlarge
Page 7

1.6.5 HUMIDITY CONTROLLER 1.6.5.1 Mechanical Type

42% R.H 40%

The humidity control can be set anywhere between Off and Max for normal operation.

If you need more dehumidification, turn the Humidity Control toward Max. If you need less dehumidification, turn the Humidity Control toward Off.

The relative humidity range is from 20% to 80%. (See Figure 6)

Turn the Humidity Control to Off to stop the unit manually.

Max. Off DEAD DIAL

1.6.5.2 Electronic Type

The humidity control can be set 'on' or 35%-70% RH(Relative Humidity) for normal operation. (See Figure 7) If you need drier air, press the Humidity Control button. If you need moister air, press the Humidity Control button.

HUMIDITY CONTROL

HUMIDITY

Press the Power button to stop the unit manually.

SETTING

Show 8 more labels / short text on this page
5(42%) · 6(35%) 4(50%) · 3(60%) · 7(30%) · 2(70%) · 8(25%) · 9(20%) · 1(80%)
Page 8 of the Frigidaire DH404EY5 user manual — 2. CIRCUIT DIAGRAM
Page 8 · click to enlarge
Page 8

2. CIRCUIT DIAGRAM

  • MODEL : DH305Y5, DH300MY5
Frigidaire DH404EY5 — 2. CIRCUIT DIAGRAM diagram (page 8)
Fig. 3
NO.DESCRIPTIPART NO. ON DH305Y5,DH300MY5Q'TY PER SETREMARKS 1POWER CORD ASSEMBLY 6411A20001Z1S 2SWITCH, ROCKER6600FX5001G1S 3MOTOR ASSEMBLY4681A20040Q1S 4CAPACITOR0CZZA20005J1S 5COMPRESSOR, SET2520UCBS0051S 6OLP6750U-L082A1S 7PWB(PCB) ASSEMBLY, DISPLAY 6871A20289B1S 8SENSOR ASSEMBLY6877A30013L1S 9SWITCH ASSEMBLY,ROTARY 6601A30001B1S 10SWITCH ASSEMBLY,MICRO 6600A30003C1S 11PWB(PCB) ASSEMBLY, MAIN 6871A10142A1S
Frigidaire DH404EY5 — 2. CIRCUIT DIAGRAM diagram (page 8)
Fig. 4

S: SERVICE PARTS A: ALTERNATE PARTS N: NOT SERVICE PARTS

Page 9 of the Frigidaire DH404EY5 user manual
Page 9 · click to enlarge
Page 9
  • MODEL : DH300EY5
Frigidaire DH404EY5 diagram (page 9)
Fig. 5
NO.DESCRIPTIONPART NO.Q'TY PER SETREMARKS DH300EY5 1POWER CORD ASSEMBLY6411A20001Z1S 2MOTOR ASSEMBLY4681A20040Q1S 3CAPACITOR0CZZA20005J1S 4COMPRESSOR, SET2520UCBS0051S 5OLP6750U-L082A1S 6PWB(PCB) ASSEMBLY, DISPLAY6871A20482A1S 7SENSOR ASSEMBLY6877A30013L1S 8SWITCH ASSEMBLY, MICRO6600A30003C1S 9PWB(PCB) ASSEMBLY, MAIN6871A10141A1S
Frigidaire DH404EY5 diagram (page 9)
Fig. 6

S: SERVICE PARTS A: ALTERNATE PARTS N: NOT SERVICE PARTS

Page 10 of the Frigidaire DH404EY5 user manual
Page 10 · click to enlarge
Page 10
Frigidaire DH404EY5 diagram (page 10)
Fig. 7
NO.DESCRIPTIONPART NO. DH400MY5/LD40Y5Q'TY PER SETREMARKS 1POWER CORD ASSEMBLY6411A20001Z1S 2SWITCH, ROCKER6600FX5001G1S 3MOTOR ASSEMBLY4681A20040J1S 4CAPACITOR0CZZA20005N1S 5COMPRESSOR (ROTARY), SET 2520UCAS0031S 6OLP (ASSEMBLY)6750U-L103A1S 7PWB(PCB) ASSEMBLY, DISPLAY 6871A20289B1S 8SENSOR ASSEMBLY6877A30013M1S 9SWITCH ASSEMBLY, ROTARY6601A30001C1S 10SWITCH ASSEMBLY, MICRO6600A30003C1S 11PWB(PCB) ASSEMBLY, MAIN6871A10142A1S
Frigidaire DH404EY5 diagram (page 10)
Fig. 8

S: SERVICE PARTS A: ALTERNATE PARTS N: NOT SERVICE PARTS

Page 11 of the Frigidaire DH404EY5 user manual
Page 11 · click to enlarge
Page 11
Frigidaire DH404EY5 diagram (page 11)
Fig. 9
NO.DESCRIPTIONPART NO.Q'TY PER SETREMARKS DH404EY5/DH400EY5 LD40EY5 1POWER CORD ASSEMBLY6411A20001Z1S 2MOTOR ASSEMBLY4681A20040J1S 3CAPACITOR0CZZA20005N1S 4COMPRESSOR,SET2520UCAS0031S 5OLP6750U-L103A1S 6PWB(PCB) ASSEMBLY,DISPLAY6871A20482A1S 7SENSOR ASSEMBLY6877A30013M1S 8SWITCH ASSEMBLY,MICRO6600A30003C1S 9PWB(PCB) ASSEMBLY,MAIN6871A10141A1S
Frigidaire DH404EY5 diagram (page 11)
Fig. 10

S: SERVICE PARTS A: ALTERNATE PARTS N: NOT SERVICE PARTS

Page 12 of the Frigidaire DH404EY5 user manual
Page 12 · click to enlarge
Page 12
Frigidaire DH404EY5 diagram (page 12)
Fig. 11
NO.DESCRIPTIONPART NO. DH504ELY5/LD50ELY5 LD65ELY5Q'TY PER SETREMARKS Y5 LD65ELY5 1POWER CORD ASSEMBLY6411A20001Z1S 2MOTOR ASSEMBLY4681A20040J4681A20040K1S 3CAPACITOR0CZZA20005J0CZZA20005J1S 4COMPRESSOR (ROTARY), SET 2520UCBA0102520UCBA0071S 5OLP.6750U-L001A6750U-L048A1S 6PWB(PCB) ASSEMBLY, DISPLAY 6871A20482A1S 7SENSOR ASSEMBLY6877A30013L1S 8SWITCH ASSEMBLY, MICRO6600A30003C1S 9PWB(PCB) ASSEMBLY, MAIN6871A10141C1S 10COIL ASSEMBLY, SOLENOID6421A20003K1S
Frigidaire DH404EY5 diagram (page 12)
Fig. 12

S: SERVICE PARTS A: ALTERNATE PARTS N: NOT SERVICE PARTS

Page 13 of the Frigidaire DH404EY5 user manual — Figure 13 Figure 14
Page 13 · click to enlarge
Page 13

3. DISASSEMBLY INSTRUCTIONS

3.1 MECHANICAL PARTS

Frigidaire DH404EY5 — 3.1 MECHANICAL PARTS diagram (page 13)
Fig. 13

3.1.1 BUCKET AND AIR FILTER

1. Turn the Humidity Control off(Mechanical type) or press the power button off. (Electronic type) 2. Disconnect the power supply. 3. Remove the bucket. (See Figure 9) 4. Pull out the air filter. (See Figure 10)

Figure 9 Figure 10

Frigidaire DH404EY5 — Figure 9 Figure 10 diagram (page 13)
Fig. 14 · Figure 9 Figure 10
Frigidaire DH404EY5 — Figure 9 Figure 10 diagram (page 13)
Fig. 15 · Figure 9 Figure 10

3.1.2 FRONT CASE AND REAR GRILLE

1. Remove 2 screws which fasten the front grille. 2. Pull the front grille forward and upward. (See Figure 11) 3. Remove 6 screws that secure the rear grille. 4. Remove the rear grille. (See Figure 12)

Figure 11 Figure 12

3.1.3. CABINET AND CONTROL BOX

Frigidaire DH404EY5 — Figure 11 Figure 12 diagram (page 13)
Fig. 16 · Figure 11 Figure 12
1. Remove the Bucket, the Air filter and Front grille according to the procedure above. 2. Remove 1 screws that fasten Control box. (See Figure 13) 3. Remove 8 screws on all sides of the cabinet. 4. Lift the Cabinet from the base.(See Figure 13) 5. Remove a screw fasten the earth wire on the inside of control box. 6. Remove 1 screw that fasten control box and unhook control box from hook on the shroud. (See Figure 14)

Figure 13 Figure 14

Page 14 of the Frigidaire DH404EY5 user manual — 3.2.5 MICRO SWITCH ASSEMBLY
Page 14 · click to enlarge
Page 14
Frigidaire DH404EY5 diagram (page 14)
Fig. 17

3.2 CONTROL PARTS

3.2.1 POWER CORD ASSEMBLY

1. After opening the control box, remove the screw that holds the ground wire. (See Figure 15) 2. Disconnect the remaining leads of the power cord from the PWB(PCB) ASSEMBLY, MAIN, then remove it from the control box.

3.2.2 SENSOR ASSEMBLY

1. Disconnect the sensor assembly from the PWB(PCB) ASSEMBLY, MAIN. 2. Remove the screw which fastens the humidity sensor. (See Figure 16) 3. Remove the thermistor from the holder. (See Figure 16) 4. Disconnect the switch wires from the micro switch assembly. (See Figure 16)

3.2.3 PWB(PCB) ASSEMBLY, MAIN

1. Disconnect all leads of the motor and the compressor from PWB(PCB) ASSEMBLY, MAIN. 2. Remove the screw which fastens the PWB(PCB) ASSEMBLY, MAIN and pull it out after unhooking from 2 rectangular holes of the control box (lower). (See Figure 17)

3.2.4 CAPACITOR 1. Remove the screw that fastens the capacitor. (See Figure 17) 2. Disconnect all leads from the capacitor and then remove it from control box.

Frigidaire DH404EY5 — 3.2.3 PWB(PCB) ASSEMBLY, MAIN diagram (page 14)
Fig. 18

3.2.5 MICRO SWITCH ASSEMBLY

1. Turn the nut counterclockwise and pull out the micro switch from the drain pan. (See Figure 18)
Page 15 of the Frigidaire DH404EY5 user manual — LD50ELY5/LD65ELY5)
Page 15 · click to enlarge
Page 15
Frigidaire DH404EY5 diagram (page 15)
Fig. 19

3.2.6 COIL ASSEMBLY, SOLENOID (DH504ELY5, LD50ELY5, LD65ELY5)

1. Disconnect the housing of the COIL ASSEMBLY, SOLENOID from the PCB(PWB) ASSEMBLY, MAIN. 2. Remove the screw that fastens the COIL ASSEMBLY, SOLENOID. (See Figure 19) 3. Pull it out upwards.

3.2.7 CONTROL PANEL

3.2.6.1 CONTROL PANEL - Mechanical Type (DH305Y5/DH300MY5/DH400MY5/LD40Y5) 1. Disconnect housing and all leads of the rocker switch, SWITCH ASSEMBLY, ROTARY and PWB(PCB) ASSEMBLY, DISPLAY from PWB(PCB) ASSEMBLY, MAIN (3.1.3) 2. Pull out the knob assembly. 3. Remove the nut which fastens the SWITCH ASSEMBLY, ROTARY. 4. Remove the knob of the rotary switch by pulling it upward. 5. Pull out the rocker switch by pushing the hooks on the both sides of rocker switch. 6. Pull out the PWB(PCB) ASSEMBLY, DISPLAY after turning over both hooks of the display cover.

Frigidaire DH404EY5 — 3.2.7 CONTROL PANEL diagram (page 15)
Fig. 20
Frigidaire DH404EY5 — 3.2.7 CONTROL PANEL diagram (page 15)
Fig. 21

3.2.6.2 CONTROL PANEL - Electronic Type (DH300EY5/DH404EY5/DH400EY5/LD40EY5/DH504ELY5/

LD50ELY5/LD65ELY5)

1. Disconnect the housing of the PWB(PCB) ASSEMBLY, DISPLAY from PWB(PCB) ASSEMBLY, MAIN (3.1.3). 2. Remove 6 screws that secure the PWB(PCB) ASSEMBLY, DISPLAY to the display cover.
Page 16 of the Frigidaire DH404EY5 user manual — 3.2.9 SHROUD AND DRAIN PAN
Page 16 · click to enlarge
Page 16

3.2.8 FAN AND MOTOR

Frigidaire DH404EY5 — 3.2.8 FAN AND MOTOR diagram (page 16)
Fig. 22
1. Turn the nut left and full out the Fan by hands carefully. 2. Remove 2 screws that fasten Heat Exchange. 3. Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 22) 4. Unfasten 3 screws that secure the Motor and earth wire. (See Figure 23) 5. Remove the Motor.

3.2.9 SHROUD AND DRAIN PAN

1. Discharge the refrigerant by using a refrigerant Recovery System. 2. After purging the unit completely, unbrace the Discharge and the Suction tube connected compressor carefully. 3. Remove 2 screws that fasten the H/E. 4. Unfasten 2 screws that secure the shroud on the sides and then lift shroud from the drain pan. (See Figure 24) 5. Unfasten 2 screws that secure the drain pan to base pan. (See Figure 25) 6. Pull the drain pan backward then take it up from the base. (See Figure 25)

Page 17 of the Frigidaire DH404EY5 user manual — 3.3.2 COMPRESSOR
Page 17 · click to enlarge
Page 17

3.3 REFRIGERATING CYCLE

Frigidaire DH404EY5 — 3.3 REFRIGERATING CYCLE diagram (page 17)
Fig. 23

3.3.1 CONDENSER, EVAPORATOR AND CAPILLARY TUBE 1. Remove the insulation on the Heater/Evaporator (H/E) assembly 2. Pierce the pinch-off tube to discharge the refrigerant, using a refrigerant recovery system. 3. After discharging the refrigerant completely, remove 2 screws between the housing assembly and the H/E. (See Figure 26) 4. Lift the H/E and open the H/E around 45 degree counterclockwise carefully. 5. Unbraze each of interconnecting tubes of the evaporator and condenser carefully. 6. Remove the H/E assembly from the orifice. (See Figure 27) 7. Unbraze the capillary tube at the connections of the condenser and evaporator. (See Figure 28) 8. Remove 4 screws between the condenser and evaporator. (See Figure 28)

Figure 26 Figure 27

Frigidaire DH404EY5 — Figure 26 Figure 27 diagram (page 17)
Fig. 24 · Figure 26 Figure 27
Frigidaire DH404EY5 — Figure 26 Figure 27 diagram (page 17)
Fig. 25 · Figure 26 Figure 27

Using Rotary Compressor models

3.3.2 COMPRESSOR

1. Discharge the refrigerant by using a refrigerant Recovery System. 2. After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections. 3. Remove the nuts and washers which fasten the compressor. (See Figure 29) 4. Remove the compressor. (See Figure 29)
Page 18 of the Frigidaire DH404EY5 user manual — CAUTION
Page 18 · click to enlarge
Page 18

3.4 HOW TO REPLACE THE REFRIGERATION SYSTEM

1. When replacing a refrigeration component, be sure to discharge the refrigerant system by using a refrigerant recovery system. 2. After discharging the unit completely, remove the desired component, and unbraze the pinch-off tubes. 3. Solder service valves into the pinch-off tube ports, leaving the valves open. 4. Solder the pinch-off tubes with service valves. 5. After doing the above procedures, the valve must be closed and left in place on the system for any subsequent procedures. 6. Evacuate as follows. 1) Connect the vacuum pump, as illustrated in Figure 31A. 2) Start the vacuum pump, slowly open manifold valves A and B two full turns counterclockwise and leave the valves open. The vacuum pump is now pulling through valves A and B to valve C by means of the manifold and entire system.

7. Recharge as follows : 1) Refrigeration cycle systems are charged from the High-side. If the total charge cannot be put in the High-side, the balance will be put in the suction line through the access valve which you installed as the system was opened. 2) Connect the charging cylinder as shown in Figure 31B. With valve C open, discharge the hose at the manifold connection. 3) Open valve A and allow the proper charge to enter the system. Valve B is still closed. 4) If more charge is required, the high-side will not take it. Close valve A. 5) With the unit running, open valve B and add the balance of the charge. a. Do not add the liquid refrigerant to the Low-

side. b. Watch the Low-side gauge; allow pressure to

rise to 30 lbs. c. Turn off valve B and allow pressure to drop. d. Repeat steps B and C until the balance of the

CAUTION

charge is in the system. 6) When satisfied the unit is operating correctly, use the pinch-off tool with the unit still running and clamp on to the pinch-off tube. Using a tube cutter, cut the pinch-off tube about 2 inches from the pinch-off tool. Use sil-fos solder and solder pinch-off tube closed. Turn off the unit, allow it to set for a while, and then test the leakage of the pinch-off connection.

If high vacuum equipment is used, just crack valves A and B for a few minutes, then open slowly with the two full turns counterclockwise. This will keep oil from foaming and being drawn into the vacuum pump.

3. Operate the vacuum pump for 20 to 30 minutes, until 600 microns of vacuum are obtained. Close valves A and B, and observe vacuum gauge for a few minutes. A rise in pressure would indicate a possible leak or moisture remaining in the system. With valves A and B closed, stop

the vacuum pump. 4) Remove the hose from the vacuum pump and place it on the charging cylinder. See Figure 31B. Open valve C. Discharge the line at the manifold connection. 5) The system is now ready for final charging.

Page 19 of the Frigidaire DH404EY5 user manual — Figure 31A-Pulling Vacuum Figure 31B-Charging
Page 19 · click to enlarge
Page 19

Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment. pinch-off tool capable of making a vapor-proof seal, leak detector, tubing cutter, hand tools to remove components, service valve.

Frigidaire DH404EY5 diagram (page 19)
Fig. 26

Figure 31A-Pulling Vacuum Figure 31B-Charging

Page 20 of the Frigidaire DH404EY5 user manual — CONDITION
Page 20 · click to enlarge
Page 20

4. TROUBLESHOOTING GUIDE

CONDITION

CAUSE

REMEDY

1. Dehumidifier does not start. (Both compressor and fan motor do not operate.)

Check power supply at outlet. Correct if none.

Poor plug contact at outlet.

Install plug properly or replace it.

Bucket is full.

If Auto Shut Off lights, empty the bucket and replace properly.

Humidity control is at Off position

Turn the humidity control switch toward Max.

Wire disconnected or loose

Connect wire. Refer to wiring diagram for terminal identification. Repair or replace loose terminal.

Capacitor. (Discharge capacitor before testing.)

Test capacitor. Replace if not within ±10% of manufacturer's rating. Replace if shorted, open, or damaged.

2. Motor runs but compressor does not run.

Voltage (115V ± 10%)

It must be between 103.5V and 126.5V. If not within limits, call an electrician

Check the wire connections; If loose, repair or replace the terminal. If the wires are disconnected, refer to wiring diagram for identification, and replace the wires. Check the wire connections; If not according to the wiring diagram, correct the connections.

Check for continuity, refer to the wiring diagram for terminal identification. Replace the switch if the circuit is open.

The Defrost Control senses frost build-up on the evaporator coil and automatically shuts off the compressor. The fan continues to run, drawing air across the coil, and melting the frost. When the coil is defrosted, the compressor automatically restarts, and dehumidifying resumes.

Capacitor (Discharge capacitor before servicing.)

Check the capacitor. Replace if not within ±10% of manufacturer's rating. Replace if shorted, open, or damaged.

Check the compressor for open circuit or ground. If open or grounded, replace the compressor.

Check the compressor OLP if externally mounted. Replace if open. (If the compressor temperature is high, remove OLP, cool, and retest.)

3. Does not defrost control.

Defrost control is defective.

Check defrost control, replace it.

4. Insufficient dehumidification

Turn dehumidifier off.

Move dehumidifier to obtain free and unobstructed air circulation.

H/E clogged with dust and dirt

Clean evaporator and/or condenser assembly

Air filter is dirty.

Clean it.

Motor is not operating.

Check Motor, repair or replace it.

Show 8 more labels / short text on this page
No power · Wiring · Rotary switch · Defrost control · Compressor · Overload protector (OLP) · Low relative humidity · Poor air circulation
Page 21 of the Frigidaire DH404EY5 user manual — CONDITION
Page 21 · click to enlarge
Page 21

CONDITION

CAUSE

REMEDY

5. Noisy operating

If cracked, out of balance, or partially missing, replace it

Loose foreign material inside the housing.

Remove it.

Tube hits frame.

Adjust tubing routine carefully.

Fan blade hits frame

Check Motor Mount. If loose, tighten it.

Internal compressor noise.

Replace compressor.

Tighten them.

Worn bearings of Motor Assembly

If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor assembly.

6. Water drips

The bucket is not installed properly.

The bucket should be properly positioned on the hangers of the drain pan.

Connection may be loose.

Check connection and repair.

Replace bucket.

Water drips when bucket removed for emptying.

Before removing bucket, the unit should be turned off.

Bucket overflows.

Check micro switch and float.

7. Compressor cycles on overload protector. (OLP)

High or low line voltage. (115V ± 10%)

Check line voltage. It must be between 103.5V and 126.5V volts. If intermittent, provide new supply.

Poor air circulation.

Move dehumidifier for free and unobstructed air flow.

Heat Exchange clogged with dust or dirt.

Clean dust or dirt on the Heat Exchange.

If not running, determine the cause. Replace if required.

Short circuit or ground in electrical circuit

Check electrical circuit. Repair.

Unit pressures not equalized

Allow 2 or 3 minutes for pressure to equalize before starting compressor.

Test the capacitor.

Check the terminals. If loose, repair or replace.

Check the system for a restriction.

Check compressor, replace compressor

Check OLP, if externally mounted. Replace if open. (If the compressor temperature is high, remove the OLP, cool, and retest.)

Show 9 more labels / short text on this page
Fan · Loose set screws · Leak in bucket · Motor · Capacitor · Wiring · Refrigeration system · Stuck compressor · Overload protector (OLP)
Page 22 of the Frigidaire DH404EY5 user manual
Page 22 · click to enlarge
Page 22
Frigidaire DH404EY5 diagram (page 22)
Fig. 27

l o r t n o C y ti d i m u H

Page 23 of the Frigidaire DH404EY5 user manual
Page 23 · click to enlarge
Page 23
Frigidaire DH404EY5 diagram (page 23)
Fig. 28
Page 24 of the Frigidaire DH404EY5 user manual
Page 24 · click to enlarge
Page 24
Frigidaire DH404EY5 diagram (page 24)
Fig. 29

d e e p S n a F m u H o C y ti d i l o r t n

Page 25 of the Frigidaire DH404EY5 user manual
Page 25 · click to enlarge
Page 25
Frigidaire DH404EY5 diagram (page 25)
Fig. 30
Page 26 of the Frigidaire DH404EY5 user manual
Page 26 · click to enlarge
Page 26
Frigidaire DH404EY5 diagram (page 26)
Fig. 31
Page 27 of the Frigidaire DH404EY5 user manual — #EV#
Page 27 · click to enlarge
Page 27
Frigidaire DH404EY5 — #EV# diagram (page 27)
Fig. 32
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
1. Dehumidifier does not start. (Both compressor and fan motor do not operate.)No powerCheck power supply at outlet. Correct if none. p.20
1. Dehumidifier does not start. (Both compressor and fan motor do not operate.)Poor plug contact at outlet.Install plug properly or replace it. p.20
1. Dehumidifier does not start. (Both compressor and fan motor do not operate.)Bucket is full.If Auto Shut Off lights, empty the bucket and replace properly. p.20
1. Dehumidifier does not start. (Both compressor and fan motor do not operate.)Humidity control is at Off positionTurn the humidity control switch toward Max. p.20
1. Dehumidifier does not start. (Both compressor and fan motor do not operate.)Wire disconnected or looseConnect wire. Refer to wiring diagram for terminal identification. Repair or replace loose terminal. p.20
1. Dehumidifier does not start. (Both compressor and fan motor do not operate.)Capacitor. (Discharge capacitor before testing.)Test capacitor. Replace if not within ±10% of manufacturer's rating. Replace if shorted, open, or damaged. p.20
2. Motor runs but compressor does not run.Voltage (115V ± 10%)It must be between 103.5V and 126.5V. If not within limits, call an electrician p.20
2. Motor runs but compressor does not run.WiringCheck the wire connections; If loose, repair or replace the terminal. If the wires are disconnected, refer to wiring diagram for identification, and replace the wires. Check the wire connections; If not according to the wiring diagram, correct the connections. p.20
2. Motor runs but compressor does not run.Rotary switchCheck for continuity, refer to the wiring diagram for terminal identification. Replace the switch if the circuit is open. p.20
2. Motor runs but compressor does not run.Defrost controlThe Defrost Control senses frost build-up on the evaporator coil and automatically shuts off the compressor. The fan continues to run, drawing air across the coil, and melting the frost. When the coil is defrosted, the compressor automatically restarts, and dehumidifying resumes. p.20
2. Motor runs but compressor does not run.Capacitor (Discharge capacitor before servicing.)Check the capacitor. Replace if not within ±10% of manufacturer's rating. Replace if shorted, open, or damaged. p.20
2. Motor runs but compressor does not run.CompressorCheck the compressor for open circuit or ground. If open or grounded, replace the compressor. p.20
2. Motor runs but compressor does not run.Overload protector (OLP)Check the compressor OLP if externally mounted. Replace if open. (If the compressor temperature is high, remove OLP, cool, and retest.) p.20
3. Does not defrost control.Defrost control is defective.Check defrost control, replace it. p.20
4. Insufficient dehumidificationLow relative humidityTurn dehumidifier off. p.20
4. Insufficient dehumidificationPoor air circulationMove dehumidifier to obtain free and unobstructed air circulation. p.20
4. Insufficient dehumidificationH/E clogged with dust and dirtClean evaporator and/or condenser assembly p.20
4. Insufficient dehumidificationAir filter is dirty.Clean it. p.20
4. Insufficient dehumidificationMotor is not operating.Check Motor, repair or replace it. p.20

Ask about the Frigidaire DH404EY5

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frigidaire DH404EY5

Be the first to ask — other owners or our team will answer.

Original document

Frigidaire DH404EY5 manual PDF

34 pages·6.7 MB·Dehumidifier·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…