
Installation Instructions Gas & Electric Dryer Instructions d’Installation Sécheuse à Gaz ou Électrique Instrucciones de Instalación Secadora a Gas y Eléctrica

www.frigidaire.com P/N 137135100B (0903)


Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered gen- erators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended.
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Grounding through the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral.
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
4-WIRE POWER SUPPLY CORD KIT (not supplied)
3-wire receptacle (NEMA type 10-30R)
4-wire receptacle (NEMA type 14-30R)
The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp, with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 3-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
The dryer MUST employ a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 4-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM.
Dryers manufactured for sale in Canada have factory- installed, 4-wire power supply cord (NEMA 14-30R).
CIRCUIT - Individual, properly polarized and grounded 15
Grounding type Grounding type wa wall receptacl ll receptacle
amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker.
Do not, Do not, under under an any cir y circumstances, cumstances, cut, cut, remo remove ve, or b or bypass th ypass the gr grounding pr ounding prong. ong.
POWER SUPPLY - 2-wire, with ground, 120 volt, single phase,
60 Hz, Alternating Current.
POWER SUPPLY CORD - The dryer is equipped with a 120 volt
3-wire power cord.
GROUNDING CONNECTION - See “Grounding requirements”
in Electrical Installation section.
Po Power cord with wer cord with 3-prong 3-prong gr grounded plug ounded plug

- EXPLOSION HAZARD - Uncoated copper tubing will corrode when subjected to natural gas, causing gas leaks. Use ONLY black iron, stainless steel, or plastic-coat- ed brass piping for gas supply.
Use only 4 inch (10.2 cm) diameter (minimum) rigid or fl exible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (30.5 cm) clearance between the vent hood and the ground or any other obstruction.

- FIRE HAZARD - Failure to follow these in- structions can create excessive drying times and fi re hazards.
The following are specifi c requirements for proper and safe operation of your dryer.
- FIRE HAZARD - Do not install a clothes dryer with fl exible plastic or metal foil venting materials. Flexible venting materials are known to collapse, be easily crushed and trap lint. These conditions will obstruct clothes dryer airfl ow and increase the risk of fi re.

If your present system is made up of plastic duct or metal foil duct, replace it with a rigid or semi-rigid metal duct. Also, ensure the present duct is free of any lint prior to installing dryer duct.
Correct Incorrect

- FIRE HAZARD - A clothes dryer must be exhausted outdoors. Do not exhaust dryer into a chimney, a wall, a ceiling, an attic, a crawl space or any concealed space of a building. A clothes dryer produces combustible lint. If the dryer is not exhausted outdoors, some fi ne lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fi re hazard.

- FIRE HAZARD - Exceeding the length of duct pipe or number of elbows allowed in the “MAXIMUM LENGTH” charts can cause an accumulation of lint in the ex- haust system. Plugging the system could create a fi re hazard, as well as increase drying times.
The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area.
- FIRE HAZARD - Do not allow combustible materials (for example: clothing, • draperies/curtains, paper) to come in contact with exhaust system. The dryer MUST NOT be exhausted into a chim- ney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fi re hazard.
Do not screen the exhaust ends of the vent system, or use • any screws, rivets or other fasteners that extend into the duct to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fi re hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fi ttings MUST be installed downstream with the fl ow of air.
- FIRE HAZARD - Do not install fl exible plastic or fl exible foil venting mate- • rial.
If installing semi-rigid venting, do not exceed 8 ft. (2.4 m) • duct length.

In installations where the exhaust system is not described in the charts, the following method must be used to determine if the exhaust system is acceptable:
Exhaust direction Directional exhausting can be accomplished by installing a quick-turn 90° dryer vent elbow directly to exhaust outlet of dryer. Dryer vent elbows are available through your local parts distributor or hardware store.

Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the performance of the dryer:
Only the rigid metal duct work should be used. •
See also CLEARANCE REQUIREMENTS on the next page.
Venting vertically through a roof may expose the exhaust • system to down drafts causing an increase in vent restriction.
Use of 90° quick-turn elbow required to meet mini- mum installation depth of free-standing dryer:
Running the exhaust system through an uninsulated area • may cause condensation and faster accumulation of lint.
Compression or crimping of the exhaust system will cause • an increase in vent restriction.
The exhaust system should be inspected and cleaned a • minimum of every 18 months with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.
Installation MUST conform to current Manufactured 1. Home Construction & Safety Standard, Title 24 CFR, Part 32-80 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSAZ240 MH. Dryer MUST be exhausted outside (outdoors, not beneath 2. the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. If dryer is exhausted through the fl oor and area beneath 3. the mobile home is enclosed, the exhaust system MUST
terminate outside the enclosure with the termination securely fastened to the mobile home structure. Refer to previous sections in this guide for other important 4. exhaust venting system requirements. When installing a gas dryer into a mobile home, a 5. provision must be made for outside make up air. This provision is to be not less than twice the area of the dryer exhaust outlet. Installer MUST anchor this (1) dryer or (2) dryer mounted 6. on pedestal to the fl oor with approved Mobile Home Installation Kit - P/N 137067200.


- EXPLOSION HAZARD - Do not install the dryer where gasoline or other fl ammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the fl oor. Failure to do so can result in death, explosion, fi re or burns.
DO NOT INSTALL YOUR DRYER: In an area exposed to dripping water or outside weather 1. conditions. In an area where it will come in contact with curtains, 2. drapes, or anything that will obstruct the fl ow of com- bustion and ventilation air. On carpet. Floor MUST be solid with a maximum slope of 3. 1 inch (2.54 cm).
F * or other than straight back venting, a quick-turn 90° dryer vent elbow (vented right or down in free-standing dryer or right on pedestal-mounted dryer) must be installed to achieve 0” (0 cm) installation.

DO NOT install your dryer in a closet with a solid door.

To achieve an installation with 0” (0 cm) clearance for the back of the dryer (for other than straight back vent- ing), a quick-turn 90° dryer vent elbow must be installed as described previously in this manual.
closet door


* To obtain these minimal depth dimensions, dryer must be vented straight back. Using a quick-turn 90° elbow (right or down on freestanding dryer) adds approximately 0.75 in. (2.0 cm) to installation depth. Upward venting of exhaust on pedestal-mounted or freestanding dryer adds approximately 4 in. (10.2 cm) to installation depth. Leftward venting on pedestal-mounted or freestanding dryer adds approximately 3.75 in. (9.5 cm) to installation depth. Downward venting of exhaust on pedestal-mounted dryer adds approximately 2.25 in. (5.7 cm) to installation depth.
3.75” (9.5cm) 13.50” (34.5cm) to center of rear vent

* To obtain these minimal depth dimensions, dryer must be vented straight back. Using a quick-turn 90° elbow (right) adds approximately 0.75 in. (2 cm) to installation depth. Upward venting of exhaust on stacked dryer adds approximately 4 in. (10.2 cm) to installation depth. Downward venting of exhaust on stacked dryer adds approximately 2.25 in. (6.5 cm) to installation depth. Leftward venting of exhaust on stacked dryer adds approximately 3.75 in. (9.5 cm) to installation depth.

The following are specifi c requirements for proper and safe electrical installation of your dryer. Failure to follow these instructions can create electrical shock and/or a fi re hazard.
- ELECTRICAL SHOCK HAZARD - A U.L.-approved strain relief must be installed onto pow- • er cord. If the strain relief is not attached, the cord can be pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock.
- ELECTRICAL SHOCK HAZARD - This appliance MUST be properly grounded. Electrical • shock can result if the dryer is not properly grounded. Follow the instructions in this manual for proper ground- ing.
Do not use an aluminum wired receptacle with a copper • wired power cord and plug (or vice versa). A chemical reaction occurs between copper and aluminum and can cause electrical shorts. The proper wiring and receptacle is a copper wired power cord with a copper wired recep- tacle.
Do not use an extension cord with this dryer. Some ex- • tension cords are not designed to withstand the amounts of electrical current this dryer utilizes and can melt, creat- ing electrical shock and/or fi re hazard. Locate the dryer within reach of the receptacle for the length power cord to be purchased, allowing some slack in the cord. Refer to the pre-installation requirements in this manual for the proper power cord to be purchased.
Dryers operating on 208 volt power supply will have longer drying times than dryers operating on 240 volt power supply.
- ELECTRICAL SHOCK HAZARD - Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded.
the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician.
DO NOT modify the plug you’ve installed on this appliance.
For a grounded, cord-connected dryer:
For a permanently connected dryer:
- ELECTRICAL SHOCK HAZARD - Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded.
For a grounded, cord-connected dryer:
DO NOT modify the plug provided with the appliance.


The dryer is equipped with a three-prong (grounding) plug 1. for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
Grounding type Grounding type wa wall receptacl ll receptacle
Do not, Do not, under under an any cir y circumstances, cumstances, cut, cut, remo remove ve, or b or bypass th ypass the gr grounding pr ounding prong. ong.
The plug must be plugged into an appropriate outlet that 2. is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician.
DO NOT cut or remove ground prong from the plug.
Po Power cord with wer cord with 3-prong 3-prong gr grounded plug ounded plug
Remove the shipping cap from gas pipe at the rear of the 1. dryer.
Open the shutoff valve in the gas supply line to allow gas 3. to fl ow through the pipe. Wait a few minutes for gas to move through the gas line.
DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualifi ed gas technician.

Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved 2. pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer for the connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefi ed gases on all pipe connections.

Check for gas system leaks with a manometer. If a 4. manometer is not available, test all connections by brushing on a soapy water solution.
Inlet Pipe on Back of Dryer elp pi N
- EXPLOSION HAZARD - NEVER test for gas leaks with an open fl ame.
The supply line must be equipped with an ap- proved manual shutoff valve. This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing. Do not block access to the gas shutoff valve.


3-wire receptacle (NEMA type 10-30R)
Neutral Neutral (center wire) (center wire)
- ELECTRICAL SHOCK HAZARD - Failure to disconnect power source before servicing could result in personal injury or even death.
Turn off power supply to outlet. 1.
Access cover Access cover
Remove the screw securing the terminal block access 2. cover in the lower corner on the back of the dryer.
Install a UL-approved strain relief according to the power 3. cord/strain relief manufacturer’s instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place.
Line 2 Line 2 (BRASS terminal) (BRASS terminal)
Neutral Neutral (SILVER terminal) (SILVER terminal)
Thread an UNPLUGGED, UL-approved, 30 amp. power 4. cord, NEMA 10-30 type SRDT, through the strain relief.
Line 1 Line 1 (BRASS terminal) (BRASS terminal)
Attach the power cord neutral (center wire) conductor to 5. the SILVER colored center terminal on the terminal block. Tighten the screw securely.
Internal ground Internal ground (GREEN screw) (GREEN screw)
Install Install UL-approved UL-approved strain relief here strain relief here
Attach the remaining two power cord outer conductors 6. to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely.
Terminal screw Terminal screw
recovery slot recovery slot
- ELECTRICAL SHOCK HAZARD - Do not make a sharp bend or crimp wiring/conductor at connections.
If a terminal screw falls during cord installation, it can be retrieved in the terminal screw recovery slot below the access panel.
Follow manufacturer’s guidelines for fi rmly securing the 7. strain relief and power cord.
Reinstall the terminal block cover. 8. DO NOT remove DO NOT remove internal ground in internal ground in
Neutral Neutral terminal terminal
If moving dryer from a 4-wire system and installing it in a 3-wire system, move the internal ground from the center terminal back to the GREEN screw next to the terminal block.

screw screw · Terminal Terminal · block block

4-wire receptacle (NEMA type 14-30R)

Neutral Neutral (WHITE wire) (WHITE wire) 30 AMP 30 AMP NEMA 14-30 NEMA 14-30
- ELECTRICAL SHOCK HAZARD - Failure to disconnect power source before servicing could result in personal injury or even death.
Turn off power supply to outlet. 1. Remove the screw securing the terminal block access 2. cover in the lower corner on the back of the dryer. Install a UL-approved strain relief according to the power 3. cord/strain relief manufacturer’s instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place. Thread an UNPLUGGED, UL-approved, 30 amp. power 4. cord, NEMA 14-30 type ST or SRDT, through the strain relief. Disconnect the internal (BLACK) dryer harness ground 5. wire from the (GREEN) ground screw next to the terminal block. Attach the ground (GREEN) power cord wire to the 6. cabinet with the ground (GREEN) screw. Tighten the screw securely. Move the internal dryer harness ground (BLACK) wire to 7. the terminal block and attach it along with the neutral (WHITE) power cord wire conductor to the center, SILVER colored terminal on the terminal block. Tighten the screw securely. Attach the RED and BLACK power cord conductors to 8. the outer, BRASS colored terminals on the terminal block. Tighten both screws securely.
Access cover Access cover
Line 2 Line 2 (BRASS terminal) (BRASS terminal)
Neutral Neutral (SILVER terminal) (SILVER terminal)
Line 1 Line 1 (BRASS terminal) (BRASS terminal)
Internal ground Internal ground (GREEN screw) (GREEN screw)
Install Install UL-approved UL-approved strain relief here strain relief here
Terminal screw Terminal screw
recovery slot recovery slot
If a terminal screw falls during cord installation, it can be retrieved in the terminal screw recovery slot below the access panel.
Neutral Neutral terminal terminal
Move internal ground (BLACK) Move internal ground (BLACK)
- ELECTRICAL SHOCK HAZARD - Do not make a sharp bend or crimp wiring/conductor at connections.
wire to neutral (SILVER) wire to neutral (SILVER) terminal for 4-wire system. terminal for 4-wire system.

Follow manufacturer’s guidelines for fi rmly securing the 9. strain relief and power cord.
Reinstall the terminal block cover. 10.
BLACK BLACK or RED or RED power wire power wire
BLACK or BLACK or RED power wire RED power wire
screw screw · Terminal Terminal · block block

Connect the exhaust duct to the outside exhaust system 1. (see pages 4 through 6). Use of a 4” (10.2 cm) clamp (item A) is recommended to connect the dryer to the exhaust vent system. Use metal foil tape to seal all other joints. Carefully slide the dryer to its fi nal position. Adjust one or 2. more of the legs until the dryer is resting solidly on all four legs. Place a level on top of the dryer. The dryer MUST be level and resting solidly on all four legs. Rock alternating corners to check for stability. Remove and discard door tape.

Be sure the power is off at a circuit breaker/ fuse box before plugging the power cord into an outlet.
Plug the power cord into a grounded outlet. 3. Turn on the power at the circuit breaker/fuse box. 4. Read the 5. Use & Care Guide provided with the dryer. It contains valuable and helpful information that will save you time and money. If you have any questions during initial operation, please 6. review the “Avoid Service Checklist” in your Use & Care Guide before calling for service. Place these instructions in a location near the dryer for 7. future reference.

A wiring diagram and technical data sheet are located inside the dryer console.

Grounding type Grounding type wa wall receptacl ll receptacle

Do not, Do not, under under an any cir y circumstances, cumstances, cut, cut, remo remove ve, or b or bypass th ypass the gr grounding pr ounding prong. ong.
Po Power cord with wer cord with 3-prong 3-prong gr grounded plug ounded plug



Figure 1 1.Open door and remove four (4) plugs in the door opening opposite the hinges. Retain all parts for uses later, unless otherwise noted. (Figure 1) Note: Use care in removing plugs
from door. Again taking care not to scratch paint on door. (Figure 4)
in not scratching paint on the front panel.


Figure 5 6. Pull handle away from door assembley. (Figure 5)
the front panel. (Figure 2) For best results, start by only removing one screw per hinge. Then only loosen the two remaining screws while firmly holding door to prevent damage
to hinge, front panel or door. After the remaining screws are loosened, continue to remove all.


Figure 6 7. Separate the outer door from the inner door assembly with
a putty knife or flat screw driver. (Figure 6)
Figure 3 3. Place door on a towel or pad handle side down to prevent any possible scratches to door. Remove all remaining four (4) screws between hinge and door. (Figure 3)







Figure 10 10. Remove two (2) transition ring plugs and reinstall on
previous handle side. (Figures 9 and 10)

Failure to use accessories manufactured by (or approved by) the manufacturer could result in personal injury, property damage or damage to the dryer.
White Pedestal - P/N NLPWD15 Black Pedestal - P/N NLPWD15E A storage pedestal accessory, specifi cally designed for this dryer may be used to elevate the dryer for ease of use. This pedestal will add about 15” (38 cm) to the height of your unit for a total height of 51.25” (130 cm).

P/N 134700600 Depending on the model you purchased, a kit for stacking this dryer on top of matching washer may have been included in the initial purchase of your dryer. If your model did not include a stacking kit or you desire another stacking kit, you may order one
15.00” 15.00” (38.10cm) (38.10cm)
P/N PCK4200 Gas dryers intended for use in a location supplied with LP must use a conversion kit prior to installation.
P/N 137067200 Installations in mobile homes require use of MOBILE HOME INSTALLATION KIT.
P/N 137067300 Depending on the model you purchased, a drying rack may have been included in the initial purchase of your dryer. If your model did not include a drying rack or you desire another drying rack, you may order one.
P/N 137019200 A UNIVERSAL APPLIANCE WRENCH is available to aid in dryer/washer/pedestal feet adjustment.
White Touch Up Pen - P/N 5303321319 Black Touch Up Pen - P/N 5304458932
If replacements parts are needed for your dryer, contact the source where you purchased your dryer, call 1-800- 944-9044 (in Canada 1-800-265-8352), or visit our website, www.frigidaire.com for the Frigidaire Authorized Parts Distributor nearest you.
- ELECTRICAL SHOCK HAZARD - Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.