Instruction/ maintenance manual of the product ZQ08A10C Friedrich
Go to page of 28
Room Air Conditioner Ser vice and P ar ts Man ual ZStar TM ZQ08 (01/01).
—2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ................................2 1.2 INSULATION RESISTANCE TEST .................2 1.3 SPECIFICATIONS ...........................................3 1.4 FEATURES...............................................
—3— 1.3 SPECIFICA TIONS POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (Btu/W.h) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP.
1.4 FEA TURES • Designed for cooling only. • Powerful and whisper cooling. • Slide-in and slide-out chassis for the simple installation and service.
— 5 — 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the INLET GRILLE downward and remove the air filter. 2. Remove the screw which fastens the FRONT GRILLE. 3. Pull the FRONT GRILLE from the right side. 4. Remove the FRONT GRILLE. 5. Re-install the component by referring to the above removal procedure.
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE AND BLO WER 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the control box. (Refer to section 2.1.3) 4. Remove the 3 screws which fasten the brace.
2.3 ELECTRICAL P AR TS 2.3.1 O VERLO AD PRO TECT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the terminal cover. (See Figure 7) 4. Remove all the leads from the overload protector. 5.
— 8 — 2.3.4 PO WER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Open the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the control box. 4. Disconnect the 2 receptacles. 5. Remove a screw which fastens the clip cord.
2.4 REFRIGERA TING CYCLE 2.4.1 CONDENSER 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the 3 screws which fasten the brace.(Refer to section 2.2.1) 3. Remove the 3 screws which fasten the condenser and shroud. 4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.
— 10 — — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
— 11 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
— 12 — 3. INST ALLA TION 3.1 INST ALLA TION HARD W ARE Type C (5) Type A (13) Bolt (2) Nut (2) Type B (3) Foam top window gasket Window sash seal Right frame curtain Window locking bracket Left frame curtain Frame guide(2) Sill support(2) 3.2 SELECT THE BEST LOCA TION Step 1.
— 13 — 3.3 WINDO W REQUIREMENTS Step 1. These instructions are for a standard double hung window. You will need to modify them for other types of windows. Step 2. The air conditioner can be installed without the frame curtain if needed to fit in a narrow window.
✓ Remove the 2 shipping screws from the back of the case. ✓ Remove the 2 screws on each side of the case. Keep these for later use. ✓ Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.
Step 1. Open the window and mark the centerline of the window stool (or desired air conditioner location). Step 2. Carefully place the case on the window stool and align the center mark on the bottom front with the centerline of the stool Step 3.
Step 1. Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Step 2. Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown.
— 17 — 4. TR OUBLESHOO TING GUIDE 4.1 OUTSIDE DIMENSIONS 525mm(20 11 / 16 ") 470mm(18 1 / 2 ") 353mm(13 7 / 8 ") 250mm(10").
— 18 — CAPILLARY TUBE COMPRESSOR BLOWER EV APORA TOR COIL : REFRIGERANT FLOW CONDENSER COIL FA N MOTOR 4.2 PIPING SYSTEM The following is a brief description of the important components and their function in what is called the refrigeration system.
— 19 — 4.3 TROUBLESHOO TING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect. The other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
— 20 — Fails to Start Check of circuit breaker and fuse. Gas leakage of feeler bulb of thermostat Check of control switch. Only fan fails to start. Improper wiring Defect of fan motor capacitor Resistance irregular motor ( ). Insulation irregular motor ( ).
— 21 — — 21 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification.
— 22 — COMPLAINT CAUSE REMEDY If cracked, out of balance, or partially missing, replace it. If cracked, out of balance, or partially missing, replace it. Tighten it. If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor.
— 23 — COMPLAINT CAUSE REMEDY If not running, determine the cause. Replace if required. Remove the cabinet, inspect the interior surface of the condenser. If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. Clean the interior base before re-assembling.
—24— 5. SCHEMA TIC DIA GRAM • CIRCUIT DIA GRAM • MODEL : ZQ08A10C 1 3 4 8 5 9 2 6 7 COMP. MOTOR WH(BL) POWER INPUT (Plain) GN(GN/YL) GN(GN/YL) BK(BR) (Ribbed) WIRING DIAGRAM 3854AR3563A BL BL RD BK R C S YL YL RD BK BL RD ROTARY SWITCH BK BL L 7 1 8 6 4 2 H M OR(BR) OR(BR) BL RD BK THERMOSTAT CAPACITOR P.
— 25 — 6. EXPLODED VIEW 17 34 62 50 52 51 48 49 6 29 28 31 26 23 24 18 19 20 27 21 29 30 3 2 10 9 7 1 22 25 61 37 36 43 42 47 46 41 40 44 16 15 14 13 12 11 8 55 56 54 58 59 57 60 35 32 45 38 E A C.
— 26 — 7. REPLA CEMENT P AR TS LIST • MODEL: ZQ08A10C A FRONT GRILLE ASSY 3531A20034C 1 R 1 673-044-02 FRONT GRILLE 3530A10026A 1 R 2 673-061-01 INLET GRILLE 3530A10028A 1 R 3 AIR FILTER ASSY 52.
— 27 — PART NO. DESCRIPTION REMARK ZQ08A10C LOCATION NO . FRIEDRICH PART NO. Q'TY PER SET C CONTROL BOX ASSY 4995A20072B 1 N 35 CONTROL BOX, SINGLE 4994A10006B 1 R 36 CONTROL PANEL ASSY 3721A.
ZQ08 (01/01) Printed in the U.S.A Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.: 3828A20038U Use F actor y Cer tified P ar ts.
An important point after buying a device Friedrich ZQ08A10C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Friedrich ZQ08A10C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Friedrich ZQ08A10C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Friedrich ZQ08A10C you will learn all the available features of the product, as well as information on its operation. The information that you get Friedrich ZQ08A10C will certainly help you make a decision on the purchase.
If you already are a holder of Friedrich ZQ08A10C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Friedrich ZQ08A10C.
However, one of the most important roles played by the user manual is to help in solving problems with Friedrich ZQ08A10C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Friedrich ZQ08A10C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center