Instruction/ maintenance manual of the product ZQ07B10 Friedrich
Go to page of 24
Room Air Conditioner Ser vice and P ar ts Man ual ZStar ® ZQ05/ZQ07 (06/05) ZQ05B10 ZQ07B10.
—2— CONTENTS 1. PREF A CE ...................................................................................................................................................3 1.1 FEA TURES...........................................................
—3— 1. PREF A CE This ser vice manual provides v arious ser vice inf or mation, including the mechanical and electr ical par ts, etc. This room air conditioner was manuf actured and assembled under a strict quality control system. The refrigerant is charged at the f actory .
—4— 1.3 LOCA TIONS OF CONTROLS 1.4 SAFETY PRECA UTIONS 1. When ser vicing, set the RO T AR Y SWITCH to Off and unplug the power cord. 2. Obser ve the original lead dress. If a shor t circuit is found, replace all parts which hav e been ov erheated or damaged by the short cir- cuit.
— 5 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Disconnect the unit from source of power . 2. Remov e the two knobs by pulling them off . Using a screwdriv er , remov e the screw that secures the front grille to control board.
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel . (Ref er to Section 2.
— 7 — 2.2.3 MO T OR 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel . (Ref er to Section 2.1.3) 5. Remov e the air guide upper .
— 8 — 2.3.2 COMPRESSOR 1. Remov e the front grille and cabinet. (Ref er to Section 2.1) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the overload protector . (Ref er to Section 2.3.1) 4. After discharging the unit completel y , unb r a z e the suction and discharge pipes at the compressor connections.
— 9 — 2.3.6 PO WER CORD 1. Disconnect the unit from source of power . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e a scr e w that secures control panel to base pan. (Ref er to Section 2.
2.4.2 E V APOR A T OR /CONDENS E R 1. Remov e the cabinet. 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the air guide upper . (Refer to Section 2.2.1) 4. After discharging the refrigerant completely , unb r a z e the interconnecting tube at the proper connections.
— 11 — Equipment needed: V acuum pump, charging cylinder , manifold gauge , brazing equipment, pinch-off tool capable of making a v apor proof seal, leak detector , tubing cutter , hand tools to remove components and service valv e.
— 1 2 — 3 . T R OUBLESHO O TING GUIDE 3 .1 OUTSIDE DIMENSIONS (unit: mm [in]) 370 (14 9 / 16 ") 312 (12 1/4 ") 370 (14 9 / 16 ") 312 (12 1/4 ") 29 (1 5 / 32 ") 120 (4 3 / 4 ") 27.5 (1 3 / 32 ") 346 (13 5 / 8 ") 472 (18 9/16 ") 42 (1 21 / 32 ") 42 (1 21 / 32 ") 155(6 3/32 ") 12 (0.
— 1 3 — 3 .2 PIPING SYSTEM Figure 2 2 is a b r ief desc r iption of the impo r tant components and their function in what is called the ref r ige r ation system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
— 1 4 — 3 .3 T R OUBLESHO O TING GUIDE In gene r al, possi b le trou b le is classified in t w o categories . The one is called Starting Failure which is caused by an electrical def ect. The other is Ineffective Air Con- ditioning caused b y a de f ect in the ref r ige r ation circuit and /or improper application.
— 1 5 — Fails to Start Improper thermostat setting Loose ter minal connection Improper wiring Che c k p o w er sourc e . Drop of pow er voltage . Capacitor check. Replacement. Che c k control s witch setting. Compressor f ails to star t. Def ect of compressor capacitor .
— 1 6 — ROOM AIR CONDITIONER V OL T A GE LIMITS NAME PLA TE RA TING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CA USE REMED Y F an motor will not run. No pow er Check v oltage at outlet. Correct if none. P ower supply cord Check v oltage to rotar y switch.
— 17 — COMPLAINT CA USE REMED Y F an motor noise. F an If crac ked, out of balance , or par tially missing, replace it. Blow er If crac ked, out of balance , or par tially missing, replace it. Loose set screw Tighten it. W orn bear ings If knocking sounds contin ue when running or loose, replace the motor .
— 18 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not running, deter mine the cause. Replace if ov er load. required. Condenser air flow Remo ve the cabinet, inspect the interior surf ace restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush.
— 19 — 4 . CIRCUIT DI A GRAM 1 2 6 7 5 3854AR2330A COMP. MOTOR ROCKER SWITCH YL BR THERMOSTAT OLP BR R BL RD BK OR(BR) CAPACITOR F H C YL ROTARY SWITCH 2H L M BK BR RD BL BK POWER INPUT BK(BR) (Plain) WH(BL) (Ribbed) GN(GN/YL) RD BL YL OR(BR) 4 6 8 1 3 5 7 BL RD BK BR WIRING DIAGRAM SYNC.
— 2 0 — 5 . EXPLODED VIEW 152302 149410 147581 147582-2 147582-1 135313 352390 135312 130410 359012 W48602 354210 349480 352380 149980 559011 346811 554030 W48602 130910 266003 264110 269310 W0CZZ.
—2 1 — 6 . SE R VICE P A R TS LIST • ZQ05 B 10 . ZQ07B10 Loc No FRIEDRICH Description 130410 67302921 BASE ASSEMBLY,WELD[SINGLE] 130910 67303709 CABINET ASSEMBLY,SINGLE 135312 67306003 GRILLE AS.
Loc No FRIEDRICH Description 130410 67302921 BASE ASSEMBLY,WELD[SINGLE] 130910 67303709 CABINET ASSEMBLY,SINGLE 135312 67306003 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306103 GRILLE,INLET 135500 673003.
— 2 3 — MEMO.
Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO.
An important point after buying a device Friedrich ZQ07B10 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Friedrich ZQ07B10 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Friedrich ZQ07B10 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Friedrich ZQ07B10 you will learn all the available features of the product, as well as information on its operation. The information that you get Friedrich ZQ07B10 will certainly help you make a decision on the purchase.
If you already are a holder of Friedrich ZQ07B10, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Friedrich ZQ07B10.
However, one of the most important roles played by the user manual is to help in solving problems with Friedrich ZQ07B10. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Friedrich ZQ07B10 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center