Instruction/ maintenance manual of the product 24 Friedrich
Go to page of 20
840-170-38 Single Package V ertical Air Conditioning System B – Series 18,000 – 24,000 – 30,000 – 36,000 – 42,000 – 49,000 – 60,000 Btuh INST ALL A TION & OPERA TION MANUAL.
2 Page T ABLE OF CONTENTS V ert-I-Pak B -Series V ertical Air Conditioning System Safety Considerations ....................................................................................................... 3 General Recommendations .................
3 SAFETY CONSIDERA TIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or dealer for information and assistance.
4 MODELS: V(E,H)B18K05 V(E,H)B18K10 V(E,H)B24K05 V(E,H)B24K10 V(E,H)B30K10 V(E,H)B30K15 V(E,H)B36K10 V(E,H)B36K15 B-SERIES CHASSIS SPECIFICA TIONS Section I – General Specifications VERT-I-P AK ® M.
5 Cooling Cap. 42000 42000 48500 48500 58000 58000 Cooling Power (W) 4500 4500 5500 5500 6450 6450 SEER 9. 8 9.8 9 .8 9. 8 9.9 9 .9 Cooling SHR 0.72 0.72 0.69 0.69 0.72 0.72 ELECTRIC AL HEAT DA T A: Heater Size (KW) 10.0 15.0 15.0 20.0 20.0 25.0 Heating Cap.
6 The Vert-I-Pak was designed for installation in residential and light commercial applications. These instructions detail a typical method of installation.
7 Unit Configuration Figure 4 1) INDOOR AND OUTDOOR AIR REQUIREMENTS The indoor and outdoor air systems are designed to operate at specified airflow rates and external static pressures.
8 VPBWP4 – 8/14 Wall Plenum Figure 6 VPBWP3 – 8/14 Wall Plenum Figure 5 For Models • VE/VHB18 • VE/VHB24 For Models • VE/VHB18 • VE/VHB24 • VE/VHB30 • VE/VHB36.
9 VPBWP5 – 8/14 W all Plenum Figure 7 VPBWP6 – 8/14 W all Plenum Figure 8 For Models • VE/VHB42 • VE/VHB49 For Model • VE/VHB60.
10 B . . . . . Ducted Condenser Air For ducted outside air applications, the combined pressure losses of the intake and discharge air paths must not exceed the external static capabilities of the system at the design airflow (See Table 3).
11 C. Indoor -Air (Conditioned Supply Air) System The VEB/VHB series unit may be applied in either a free return air configuration or a ducted return air configuration.
12 2) Electrical A. Grounding CAUTION: The unit must be electrically wired and grounded in accordance with all state and local codes, national electric code, and NFPA 70. Unit and controls will NOT operate unless properly grounded. A ground lug is provided for ground connection.
13 B. Thermostat Mounting and Wiring The thermostat is a precision instrument and was carefully adjusted at the factory . Handle it carefully . CAUTION: Disconnect the power supply before beginning installation of the thermostat to prevent electrical shock or equipment damage.
14 4) CONDENSA 4) CONDENSA 4) CONDENSA 4) CONDENSA 4) CONDENSA TE DRAIN LINE TE DRAIN LINE TE DRAIN LINE TE DRAIN LINE TE DRAIN LINE The condensate drain exits the unit 2" above floor level at the right side front corner of the unit. The condensate drain line is already internally trapped therefore, no external condensate trap is required.
15 IDENTIFYING YOUR SYSTEM Take the time to familiarize yourself with the type of system you have. This knowledge will be of use in understanding the basic operation of your unit. A self-contained unit, like the Vert-I-Pak, has all of its major components in one cabinet located inside your home.
16 The temperature control is a selector or set of buttons that allows you to establish the degree of temperature that you wish to maintain for your personal comfort. Some thermostats have two temperature control selectors: one for setting the temperature desired during the cooling cycle, and one for setting the heating operation temperature.
17 System Control The SYSTEM or MODE control on your thermostat offers the following selections: COOL, OFF, HEAT, and EM HEAT. Neither the cooling nor heating equipment will operate when the SYSTEM or MODE control is set to OFF. With the SYSTEM or MODE control set to COOL, your unit will operate in cooling mode.
18 PERFORMING ROUTINE MAINTENANCE With the proper maintenance and care, your system will operate economically and dependably. Maintenance can be accomplished easily by referring to the following directions. However, before performing any maintenance, consider these important safety precautions: WARNING: Electrical Shock Hazard.
19 INSPECT AND CLEAN INDOOR-AIR COIL Eventually, minor amounts of lint and dirt may pass through the filter and collect on the indoor-air coil. These minor accumulations can be carefully vacuumed away with a brush attachment on a vacuum cleaner. Care must be taken to avoid bending the aluminum fins on the coil.
20 Use Factory-Certified Parts FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO . . . . . P ost Office Box 1540 • San Antonio , T exas 78295-1540 4200 N.
An important point after buying a device Friedrich 24 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Friedrich 24 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Friedrich 24 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Friedrich 24 you will learn all the available features of the product, as well as information on its operation. The information that you get Friedrich 24 will certainly help you make a decision on the purchase.
If you already are a holder of Friedrich 24, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Friedrich 24.
However, one of the most important roles played by the user manual is to help in solving problems with Friedrich 24. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Friedrich 24 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center