This manual contains propriety and confidential information of Foxcom Reproduction, release to any third party, or any other unauthorized use, of any information contained herein is expressly forbidden.
The information contained in this document is believed to be accurate as of the time of going to press. Specifications are subject to change without notice.
Beck Science Center 8 Hartom Street, Har Hotzvim P.O.Box 45092 Jerusalem 91450 Tel: +972-2-589-9888 Fax: +972-2-589-9898
Princeton Forrestal Village 136 Main Street Suite 300 Princeton, NJ 08540 Tel: 609-514-1800 Toll free: 1-866-ONEPATH Fax: 609-514-1881
Block 4, Kingfisher Office Park 228 Siphosethu Rd. Mt. Edgecombe Durban, KwaZulu Natal Tel. +278 7.751.3911 Fax +278.6.501.6624
Corporate Office Israel · US Office · South Africa Office


1.1 Options 2 1.2 Product Drawings 3 1.3 Panel Descriptions 4 1.4 Block Diagrams 5
The 7870 IFL is a 10 – 200 MHz IF fiber optic link used primarily in short distance, single channel video applications with high input/ output power levels. The 7870 IFL consists of an optical transmitter (7870T) which receives signals from satellite modems, video modulators, or exciters and transmits them to an optical receiver (7870R) via singlemode fiber.
The 7870T and 7870R modules plug into a 7180M, a 3U chassis and power supply, which enables expansion of the system to accommodate up to eight Sat-Light™ modules. Accessories include the Model 7001P Power Supply, the Model 2040 1:1 Redundant Switch, the Model 2100 Amplifier, and the Model 7050 Serial Optical Multiplexer, an asynchronous data transceiver.
The 7870 IFL transmits all satellite modulation schemes - digital or analog. Any FM modulated RF signal is transmitted accurately. The RF signal is directly modulated and adds virtually no phase noise to the original signal. The direct modulation, along with extremely flat amplitude and group delay, guarantees low bit error rate (BER) and high signal quality, independent of distance.
LEDs, and back panel monitors, and alarms allow for complete system status monitoring and for interfacing with monitor and control (M&C) systems. Gain Control at the Receiver sets the RF level.
7870 Interfacility Link Installation and User’s Guide page 1 Foxcom proprietary information

1.1 Options
The 7870 Interfacility Link comes with a variety of options: 1. 50 Ω Input/Output Impedance/BNC female connector; Standard impedance is 75 Ω/BNC, female connectors. 2. Standalone unit; The 7870 IFL can be installed as a standalone unit. If the 7870 is used as a standalone, a separate power supply must be used.
On the side of the 7870T and the 7870R units is a label1 which lists the options. Under each option is a square. If the unit includes a particular option the square under the option should be marked.

Figure 1 Option Label

1.2 Product Drawings

Figure 2 7870T Transmitter Front and Rear Panel

Figure 3 7870R Receiver Front and Rear Panel
7870 Interfacility Link Installation and User’s Guide page 3 Foxcom proprietary information

1.3 Panel Descriptions
On the Front Panel of the 7870 IFL units are two LEDs. Both LEDs should be on when the unit is in use. T
The LEDs on the Front Panel of the 7870 Transmitter and Receiver are:
Table 1 7870T Transmitter LEDs
Table 2 7870R Receiver LEDs

1.4 Block Diagrams

Figure 4 7870Transmitter Block Diagram

Figure 5 7870R Receiver Block Diagram
7870 Interfacility Link Installation and User’s Guide page 5 Foxcom proprietary information

1.4 Block Diagrams

Chapter 2 describes how to install the 7870 Interfacility Link units. Setting up the 7870E Transmitter/Receiver consists of:
2.1 Setting up the Transmitter 8 2.2 Connecting the Fiber Optic Cable 9 2.3 Setting Up the Receiver 10 2.4 Powering the IFL 11 2.4.1 7180M Chassis 12 2.5 Connecting the Back Panel Jumpers 13 2.6 Aligning the Fiber Optic Link 15
Observe all warnings and cautions mentioned at the beginning of this manual (See Important Information on page iii).
If after set-up you experience problems, see Chapter 4 Troubleshooting on page 25.

Figure 6 Typical Application of a 7870 Interfacility Link
7870 Interfacility Link Installation and User’s Guide page 7 Foxcom proprietary information

2.1 Setting up the Transmitter
The signal level should be -4.5 ± -0.3VDC. 4. On the rear panel, connect the coax cable to the RF Input Connector. The RF LED should be lit. 5. On the rear panel, connect the fiber optic cable to the Optical Connector.

2.2 Connecting the Fiber Optic Cable
Before connecting the cable: 1. The fiber optic cable must be either fusion spliced or connected via FC/APC connectors. 2. Wipe the connector with a lint-free cotton cloth. 3. Note the polarity key of the optical connector before inserting.
To connect the cable:



7870 Interfacility Link Installation and User’s Guide page 9 Foxcom proprietary information

2.3 Setting Up the Receiver
For more information see 2.6 Aligning the Fiber Optic Link on page15. 2. If the LED is not lit, see Chapter 4 Troubleshooting on page 25.

2.4 Powering the IFL
7870 Interfacility Link Installation and User’s Guide page 11 Foxcom proprietary information

2.4 Powering the IFL
7870 Interfacility Link Installation and User’s Guide page 12
The 7180M Chassis provides power to the plug in units. The power supply is a switching type. Each plug-in

regulates its own voltage. The power supply provides:
Figure 7 7180M Chassis Rear View
Foxcom proprietary information



2.5 Connecting the Back Panel Jumpers
optional 2040 1:1 Redundant Switch, and one is for the 7180M. A 2 pin jumper (female) is placed on the relevant pins to
7870 Interfacility Link Installation and User’s Guide page 13
complete the connection between the 7180M and the units. For example, if a 2040 Switch is being used, the jumper is
connecting point between the slots and the back panel. One pin is for the transmitter/receiver (Tx/Rx), one is for the
On the rear panel of the 7180M Back Panel are product selectors (JP1 to JP4). The 3 pin selectors (male) are the
jumpers on the lower two pins.
placed on the Switch-7180M pins.
To connect the jumpers:
Foxcom proprietary information



2.5 Connecting the Back Panel Jumpers
7870 Interfacility Link Installation and User’s Guide page 14
jumpers on the higher two pins.
Foxcom proprietary information

2.6 Aligning the Fiber Optic Link
The final step in installing the 7870 Interfacility Link is re-adjusting the Receiver Gain Control for unity gain.
To set the unity gain (standard version) 1. Set the Signal Generator to -15 dBm. Alternatively measure the operational input level. 2. Set up the system as shown in Figure 12 Fiber Optic Alignment Setup 3. Adjust the Receiver Gain Control for -15 dBm reading on the power meter.

Figure 12 Fiber Optic Alignment Setup
7870 Interfacility Link Installation and User’s Guide page 15 Foxcom proprietary information

2.6 Aligning the Fiber Optic Link

3.1 7870 Interfacility Link Specifications
3.1 7870 Interfacility Link Specifications 17 3.2 Model Dimensions 19 3.3 7870 Interfacility Link Pinouts 20 3.3.1 Transmitter Pinout 20 3.3.2 Receiver Pinouts 21 3.4 7180M Chassis Pinouts 22 3.4.1 7180M Alarm Connector Pinouts [J12] 23 3.4.2 7180M Monitor Connector Pinout [J13] 24 3.4.3 7180M and Redundancy Switching 24
Frequency range 10 - 200 MHz
Flatness 10 – 200 MHz @ unity gain ± 0.4 dB [typical]
Flatness @ 36 MHz ± 0.2 dB [max.]
CNR 45 dB @ 36 MHz
Noise Figure [50 Ω]
@ unity gain / 1 dB optical loss @ unity gain / 8 dB optical loss1
28 dB [typical] 35 dB [typica]
Noise Figure [75 Ω]
@ unity gain / 1 dB optical loss @ unity gain / 8 dB optical loss1.
30 dB [typical] 37 dB [typica]
OIP3 @ -10 dBm in / 0 dBm out 24 dBm
Group delay variation @ 20 - 200 MHz
Input /output impedance 75 Ω [50 Ω optional]
Third order modulation - 50 dBc with 2 equal carrier, total input power -5 dBm
Input signal range [total power] -25 to - 5 dBm
Output signal range [total power] -25 to - 5 dBm
Maximum input without damage +10 dBm
Receiver gain control Manual
RF connector BNC female [default] F, and SMA [optional]
Test port coupling 20 dBc
Table 3 7870 Interfacility Link Specifications
7870 Interfacility Link Installation and User’s Guide page 17 Foxcom proprietary information

3.1 7870 Interfacility Link Specifications
Optical Wavelength 1310 ± 10 nm
Optical power output 0.5 mW/-2 dBm [minimum]
Optical budget / distance 16 dB / 40 Km
Optical return loss -60 dB
Optical connector loss 0.5 dB/mated pair Physical Specifications
Chassis capacity 8 plug-ins, and 2 power supplies
Chassis size 19” × 3U × 7”
Power for rackmount [max.] 100 to 240 VAC 50/60Hz 90 Watts
Standalone size 5” × 4.8” × 1.3”
Transmitter +14 VDC @ 200 mA max. [300 mA temp.< 10° C)
Receiver +14VDC @ 250 mA max.
Operating Temperature Range -10°C to +55°C
Storage Temperature Range -40°C to +85°C
All specifications are subject to change without prior notice
Optical connector FC/APC · Power for standalone

3.2 Model Dimensions

Figure 13 Unit dimensions

Figure 14 7810M Chassis Dimensions
7870 Interfacility Link Installation and User’s Guide page 19 Foxcom proprietary information

3.3 7870 Interfacility Link Pinouts
Standalone 9-Pin Connector [J13]
7180M Chassis Backplane Connector
2380 Relay Adapter Connector Name Description
1 — — +14V Power 200 mA [max ≥ 10°C]1
2 — — Spare Not Used
J4-P25 GND Chassis Ground
4 J13-P1 to J13-P8 J4-P1 to J4-P8 RSSI RF signal strength indicator: range 0.2 - 10 V
5 J13-P9 to J13-P16
J4-P9 to J4-P16 PDI Indicates laser optical power: range -4.2 to 4.8
6 J13-P17 to J13-P24 J4-P17 to J4-P24 LSRI Indicates Laser Bias; Range
RFA RF Alarm: Open collector interface.2 Sinks current when RF level is low, up to 30 mA.
8 J12-P9 to J12-P16
See note below OPTA Optical Alarm: Open Collector Interface2.. Sinks current at low optical, up to 30 mA.
9 J11-P1 to J11-P6 Spare Not used
Table 4 7870T Transmitter Pinout

Figure 15 7870T Transmitter pinout

3.3 7870 Interfacility Link Pinouts
Standalone 9 Pin Connector [J14]
2380 Relay Adapter Connector Name Description 1 — — +14V Power 350 mA 2 — — Spare Not Used 3 J11-P9 J12-P25 J13-P25
J4-P25 GND Chassis Ground
4 J13-P1 to J13-P8 J4-P1 to J4-P8 RSSI RF signal strength indicator: range 0.2 - 10 V 5 J13-P9 to J13-P16 J4-P9 to J4-P16 PDI Indicates input optical power: 1 V/ 1 m optical power 6 — — Spare Not used 7 J12-P1 to J12-P8 J2: P1-P2 P3-P4, P5-P6 P7-P8, P9-P10 P11-P12 P13-P14 P15-P16
RFA RF Alarm: Open collector interface.1 Sinks current when RF level is low, up to 30 mA.
8 J12-P9 to J12-P16 See note below OPTA Optical Alarm: Open Collector Interface1.. Sinks current at low optical, up to 30 mA. 9 — — Spare Not used
Table 5 7870R Receiver Pinout

Figure 16 7870R Receiver pinout
7870 Interfacility Link Installation and User’s Guide page 21 Foxcom proprietary information


3.4 7180M Chassis Pinouts
The unit’s pins are found at the backplane of the 7180M chassis. The 7180M chassis backplane incorporates eight slots.
Pinouts from the 9-pin connector at each slot are sent through the backplane assembly to the two 25-pin D-connectors,
7870 Interfacility Link Installation and User’s Guide page 22
J12 and J13, and one 9-pin connector, J113. Any monitor voltages to be measured may be done between the chassis
For more information about pinouts, see Appendix 4 Pinout Charts and Diagrams on page 41.
Figure 17 7180M Chassis rear view

Figure 18 7180M Chassis Pin numbers
ground and the required pin.
Foxcom proprietary information
![Page 31 of the Foxconn 7870 user manual — 3.4.1 7180M Alarm Connector Pinouts [J12]](/cdn/reader/7c/7c521e980d6487cf8293264cd204ee3baf6019039f4a012872e3dd60ccf8580f/images/page-31.webp?w=400)
3.4 7180M Chassis Pinouts
Pin No. Function Name Slot No.
1 RF Alarm RfAlm1 1
2 RF Alarm RfAlm2 2
3 RF Alarm RfAlm3 3
4 RF Alarm RfAlm4 4
5 RF Alarm RfAlm5 5
6 RF Alarm RfAlm6 6
7 RF Alarm RfAlm7 7
8 RF Alarm RfAlm8 8
9 Optical Alarm OptAlm1 1
10 Optical Alarm OptAlm2 2
11 Optical Alarm OptAlm3 3
12 Optical Alarm OptAlm4 4
13 Optical Alarm OptAlm5 5
14 Optical Alarm OptAlm6 6
15 Optical Alarm OptAlm7 7
16 Optical Alarm OptAlm8 8
21 Standby Power Supply SPSNOP
22 Standby Power Supply SPSCOM
23 Main Power Supply MPSNOP
24 Main Power Supply MPSCOM
25 Chassis Ground GND
Table 6 7180M Alarm Connector [J12] Pinouts
7870 Interfacility Link Installation and User’s Guide page 23 Foxcom proprietary information

3.4 7180M Chassis Pinouts
Pin # Function Name
1 RSSI Monitor RSSI 1
2 RSSI Monitor RSSI2 2
3 RSSI Monitor RSSI3 3
4 RSSI Monitor RSSI4 4
5 RSSI Monitor RSSI5 5
6 RSSI Monitor RSSI6 6
7 RSSI Monitor RSSI7 7
8 PDI Monitor RSSI8 8
9 PDI Monitor PDI1 1
10 PDI Monitor PDI2 2
11 PDI Monitor PDI3 3
12 PDI Monitor PDI4 4
13 PDI Monitor PDI5 5
14 PDI Monitor PDI6 6
15 PDI Monitor PDI7 7
16 PDI Monitor PDI8 8
17 LSRI Monitor LSR1 1
18 LSRI Monitor LSR2 2
19 LSRI Monitor LSR3 3
20 LSRI Monitor LSR4 4
21 LSRI Monitor LSR5 5
22 LSRI Monitor LSR6 6
23 LSRI Monitor LSR7 7
24 LSRI Monitor LSR8 8
25 Chassis Ground GND
Table 7 7180M Monitor Connector [J13] Pinout
The 2040 Switch provides optional 1:1 redundancy switching for all Foxcom Interfacility Links. If the customer chooses to add redundancy switching to the link, the pin connector jumpers need to be moved.
Detailed instructions on moving the jumpers are provided in the Model 2040 1:1 Redundant Switch Installation and User’s Guide (Document Number 93-005-26-A2).

The 7870D Interfacility Link unit was tested before it left the factory. However if you are experiencing difficulties see the list below for possible solutions. if you are still experiencing problems, attempt to isolate and identify the malfunctioning unit before consulting Foxcom’s technical support.
Table 8 Troubleshooting the Transmitter
and -4.8VDC. If not, laser may have overheated. Disconnect power or remove plug and allow to cool. Try again with better airflow. c. If an optical power meter is avail-
able, measure the optical power out of the transmitter. The power should between 0.5 mW[-3 dBm]. If an optical power meter is not avail- able, use another receiver to deter- mine if there is optical power emerging from the transmitter (use a 5 meter jumper cable). If there is no optical power, then the transmit- ter unit is malfunctioning.
If any or all the above are not within the guidelines, the transmitter unit is faulty. 2. The RF LED is not lit
The input signal is less than -28 dBm; verify RF signal strength [RSSI] is≤0.2 VDC. [See Table 4 7870T Transmitter Pinout on page 20]. Even if slightly out of range, the unit may still function, although it will register an alarm condition. 3. RF LED illuminated - with no input signal
Unit may be receiving stray RF “pick up”. Solution: provide RF input or use necessary termination input.`
7870 Interfacility Link Installation and User’s Guide page 25 Foxcom proprietary information

Table 9 Troubleshooting the Receiver
If a spectrum analyzer or power meter is not available then use a DVM and adjust the gain control for RF signal strength (RSSI) so that the reading is > 0.2VDC. (See Table 5 7870R Receiver Pinout on page 21).
Conclusion: If signal still not present then transmitter input stage amplifier or receiver amplifier is defective. Contact factory. 2. No optical power, LED not illuminated.
a. Transmitter is not functioning, see above. b. There is a break or severe bend in the fiber optic cable. Use an optical power meter or another functioning receiver unit to verify optical power coming down the fiber. c. The connector is dirty. Clean it. d. Optical power too low, too many
splits, too long a distance (thus exceeding optical budget). System may still function without LED illuminated although at reduced performance. 3. Optical power light illuminated with disconnected optical input.
Damaged (leaky) photodiode. Unit may still function, otherwise contact Factory for service.
Verify that the RF signal strength (RSSI) is

Appendix 1.1 Cleaning Procedures for FC/APC Connectors 28 Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports 29 Appendix 1.2.1 Swab Method 29 Appendix 1.2.2 Compressed Air Method 29
The unit has an FC/APC angle polished optical connector for very high optical return loss performance. The units are specified into single mode fiber i.e. 9/125 micron core diameter. Full performance is specified only for low return loss optical plant - meaning that the fiber must be fusion spliced and all connections or splices must have a return loss greater than -60 dB. With these guidelines in mind, link lengths beyond 20 kilometers (DFB based products) can be achieved with high performance. Specific performance and/or design assistance is available by request from Foxcom.
If there is low/no signal or noisy signal at a Foxcom module, the connector should be cleaned. Dirt on the inside connector tip can impair the flow of light causing problems in signal transmission. Foxcom modules are sealed but dirt can occasionally enter during installation and alignment.
The input and output optical ports of all Foxcom equipment are known in the fiber optic world as bulkhead ports. Foxcom uses FC/APC connectors.
The following materials are representative of the types of cleaning materials that should be used for cleaning the fiber optic ports and connectors. They are available from several suppliers.
Kim wipes Kimberly Clark
Cletop Automatic Connector Cleaner Cletop
fiber optic Swab Cletop or FIS
fiber optic Compressed Air Chemtronics
Table 10 Cleaning materials
Wiping clothes should be made of lint free alcohol free nonabrasive materials. Swabs should have a tightly wrapped tip and be talcum- free. For removing dust from receptacles, a canned compressed gas is recommended. Do not use commercial compressed air because of risk of contamination.
7870 Interfacility Link Installation and User’s Guide page 27 Foxcom proprietary information

Appendix 1.1 Cleaning Procedures for FC/APC Connectors
Use a Kim Wipe to gently wipe the end face surface of the connector. Alternatively a Cletop automatic connector cleaner can be used.

Figure 19 Wiping the connector with a Kim wiper

Figure 20 Wiping the connector with a Kim wiper [2]

Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports
Using a clean fiber optic cleaning swab, gently wipe out the optical port. Discard the swab after use.

Figure 21 Cleaning the Optical Port

Figure 22 Cleaning the Optical Port [2]
Using the extension tube of the compressed air, blow into the port to remove any dust or debris. Do not allow the tube to touch the bottom of the port. Do not use commercial compressed air due to potential oil contamination.
7870 Interfacility Link Installation and User’s Guide page 29 Foxcom proprietary information

Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports

To install the 7870T-STD or 7870R--STD Standalone: 1. Place the 7870 unit on the standalone flange, matching the holes. 2. Using four screws (#4 or #6) secure the unit and the flange to the wall. 3. Apply AC power to the standalone power supply unit. 4. Connect the 7870 unit to the power supply. The Laser LED should be lit.
All remaining steps are the same as in the product manual. See sections 2.1 Setting up the Transmitter on page8 and 2.3 Setting Up the Receiver on page10.
7870 Interfacility Link Installation and User’s Guide page 31 Foxcom proprietary information



Appendix 3.1 Installing the 2380 Relay Adapter 34 Appendix 3.1.1 Parts Required for Installing the 2380 34 Appendix 3.1.2 Mounting the the 2380 Relay Adapter 34 Appendix 3.2 2380 Dimensions and Front Panel Label 36 Appendix 3.3 2380 Adapter Pinouts 37
The following section describes how to install the 2380 Relay adapter onto the 7180M Chassis. The 2380 Relay adapter assembly provides dry contact output signals as an option to the standard open collector signals available on the 7180M chassis backplane.
If the 2380 Relay adapter is ordered separately from the 7180M chassis, it must mounted by the user. The 2380 is mounted directly over the connectors on the 7180M backplane, as shown below.
7870 Interfacility Link Installation and User’s Guide page 33 Foxcom proprietary information

Appendix 3.1 Installing the 2380 Relay Adapter

Figure 23 Installing the guide pins

Figure 24 Mounting the adapter

Appendix 3.1 Installing the 2380 Relay Adapter

Figure 25 Mounting the Screws [1]

Figure 26 Mounting the screws [2]

Figure 27 Mounted 2380 Adapter
7870 Interfacility Link Installation and User’s Guide page 35 Foxcom proprietary information

Appendix 3.2 2380 Dimensions and Front Panel Label

Figure 28 2380 Dimensions

Figure 29 2380 Front Label

Appendix 3.3 2380 Adapter Pinouts
Table 11 2380 Alarms Pinouts [J2]
Pin Number Function Name Slot Number 1 Alarm NOP1 1 2 Alarm COM1 1 3 Alarm NOP2 2 4 Alarm COM2 2 5 Alarm NOP3 3 6 Alarm COM3 3 7 Alarm NOP4 4 8 Alarm COM4 4 9 Alarm NOP5 5 10 Alarm COM5 5 11 Alarm NOP6 6 12 Alarm COM6 6 13 Alarm NOP7 7 14 Alarm COM7 7 15 Alarm NOP8 8 16 Alarm COM8 8 17 18 19 20 21 22 23 Main PS Alarm MPSA 24 Standby PS Alarm SPSA 25 Power Supply Comm. PSCOM
7870 Interfacility Link Installation and User’s Guide page 37 Foxcom proprietary information

Appendix 3.3 2380 Adapter Pinouts
Table 12 7180M Monitor Connector [J4] Pinout
Pin # Function Name Slot No.
1 RSSI Monitor RSSI1 1
2 RSSI Monitor RSSI2 2
3 RSSI Monitor RSSI3 3
4 RSSI Monitor RSSI4 4
5 RSSI Monitor RSSI5 5
6 RSSI Monitor RSSI6 6
7 RSSI Monitor RSSI7 7
8 RSSI Monitor RSSI8 8
9 PDI Monitor PDI1 1
10 PDI Monitor PDI2 2
11 PDI Monitor PDI3 3
12 PDI Monitor PDI4 4
13 PDI Monitor PDI5 5
14 PDI Monitor PDI6 6
15 PDI Monitor PDI7 7
16 PDI Monitor PDI8 8
17 LSRI Monitor LSRI1 1
18 LSRI Monitor LSRI2 2
19 LSRI Monitor LSRI3 3
20 LSRI Monitor LSRI4 4
21 LSRI Monitor LSRI5 5
22 LSRI Monitor LSRI6 6
23 LSRI Monitor LSRI7 7
24 LSRI Monitor LSRI8 8

Figure 30 2380 Pin Number
25 Chassis Ground


Document no. 93-005-35-C5 page 40

7180M LNB Powering Connector Pinouts (J11)

2380 Alarm Connecter Pinouts (J2)
7180M Alarm Connector Pinouts (J12)

2380 Monitor Connector Pinouts (J4)
P18 LSRI2
P19 LSRI3
P20 LSRI4
P21 LSRI5
P22 LSRI6
P23 LSRI7
P24 LSRI8
P1 RSSI1
P2 RSSI2
P3 RSSI3
P4 RSSI4
P5 RSSI5
P6 RSSI6
P7 RSSI7
P8 RSSI8
P9 PDI1
P10 PDI2
P11 PDI3
P12 PDI4
P13 PDI5
P14 PDI6
P15 PDI7
P16 PDI8
P25 GND
Figure 31 Standard 7180M and 7180M with 2380 Relay Adapter Pinout

J13P12
J13P20
J12P4
J12P12
J13P11
J13P19
J12P11
J13P3
J12P3
P9 LNB4**
P1 15VDC
P3 GND
P4 RSSI4
P5 PDI4
**No LNB Signal in IF Links, or in L-Band Rx
P4 RSSI3
P9 LNB3**
P3 GND
P5 PDI3
A4/J1
*LSRI Signal in a Tx Spare in an Rx
J13P10
J13P18
J12P10
J13P2
J12P2
P1 15VDC
P9 LNB2**
J13P1
J13P9
J13P17
J12P1
J12P9
P3 GND
P4 RSSI2
P5 PDI2
A2/J1
P1 15VDC
P4 RSSI1
P9 LNB1**
P3 GND
P5 PDI1
A1/J1

Document no. 93-005-35-C5 page 41


7180M LNB Powering Connector Pinouts (J11)


7180M Alarm Connector Pinouts (J12)
P8 Chan A Optical Alarm P4 Chan A RSSI
J13P12
J13P20
J12P4
J12P12
P18 Remote Control A/B (Slot 2)
P21 Remote Control A/B (Slot 5)
7180M Monitor Connector Pinouts (J13)
J13P19
J12P11
Not functional in this setup
Not functional in this setup
P10 Local/Remote (Slot 2)
P13 Local/Remote (Slot 5)
J12P3
P1 15VDC
Figure 32 7180M and 2040 RF Switch Pinout
P4 RSSI4
P5 PDI4
P1 15VDC
P4 RSSI3
A1J1P4 P1 RSSI1
P3 RSSI3
P4 RSSI4
P6 RSSI6
P7 RSSI7
P8 RSSI8
P12 PDI4
P14 PDI6
P15 PDI7
P16 PDI8
P17 LSRI1
P19 LSRI3
P20 LSRI4
P22 LSRI6
P23 LSRI7
P24 LSRI8
P25 GND
P3 GND
P5 PDI3
P9 PDI1
P11 PDI3
A3/J1
RX
A3J1P4
A4J1P4
A6J1P4
A7J1P4
A8J1P4
A1J1P5
A2J1P5
A3J1P5
A4J1P5
A5J1P5
A6J1P5
A7J1P5
A8J1P5
A1J1P6
A2J1P6
A3J1P6
A4J1P6
A5J1P6
A6J1P6
A7J1P6
A8J1P6
**No LNB Signal in IF Links, or in L-Band Rx
*LSRI Signal in a Tx Spare in an Rx
J13P10
J13P18
J13P1
J13P9
J13P17
J12P1
J12P9
P6 Remote Control A/B
P8 Chan A Optical Alarm P4 Chan A RSSI
P9 Chan B Optical Alarm
P4 Chan B RSSI
P4 RSSI1
P1 15VDC
P3 GND
P3 GND
P5 PDI1


Figure 33 Pinout of 7180M Jumper with 2040 RF Switch in slots 2 and 5


Figure 34 Pinout of 7180M jumper with 2040 RF switch in slot 5
7870 Interfacility Link Installation and User’s Guide page 43 Foxcom proprietary information


Figure 35 Pinout of 7180M jumper with 2040 RF switch in slot 5

Figure 36 Pinout of 7180 jumper with transmitter and receiver units only
7870 Interfacility Link Installation and User’s Guide page 45 Foxcom proprietary information


Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 1. Laser LED not on | a. No DC power to the unit. Possible power supply problem or AC power input problem. Check the power supply fuse. b.Verify LSRI monitor is between -4.2 and -4.8VDC. If not, laser may have overheated. Disconnect power or remove plug and allow to cool. Try again with better airflow. c. If an optical power meter is avail- able, measure the optical power out of the transmitter. The power should between 0.5 mW[-3 dBm]. If an optical power meter is not avail- able, use another receiver to deter- mine if there is optical power emerging from the transmitter (use a 5 meter jumper cable). If there is no optical power, then the transmit- ter unit is malfunctioning. If any or all the above are not within the guidelines, the transmitter unit is faulty. | p.33 | |
| 2. The RF LED is not lit | The input signal is less than -28 dBm; verify RF signal strength [RSSI] is≤0.2 VDC. [See Table 4 7870T Transmitter Pinout on page 20]. Even if slightly out of range, the unit may still function, although it will register an alarm condition. | p.33 | |
| 3. RF LED illuminated - with no input signal | Unit may be receiving stray RF “pick up”. Solution: provide RF input or use necessary termination input.` | p.33 | |
| 1. Lack of RF signal present at Receiver, yet optical power is functioning. | If a spectrum analyzer or power meter is not available then use a DVM and adjust the gain control for RF signal strength (RSSI) so that the reading is > 0.2VDC. (See Table 5 7870R Receiver Pinout on page 21). Conclusion: If signal still not present then transmitter input stage amplifier or receiver amplifier is defective. Contact factory. | p.34 | |
| 2. No optical power, LED not illuminated. | a. Transmitter is not functioning, see above. b. There is a break or severe bend in the fiber optic cable. Use an optical power meter or another functioning receiver unit to verify optical power coming down the fiber. c. The connector is dirty. Clean it. d. Optical power too low, too many splits, too long a distance (thus exceeding optical budget). System may still function without LED illuminated although at reduced performance. | p.34 | |
| 3. Optical power light illuminated with disconnected optical input. | Damaged (leaky) photodiode. Unit may still function, otherwise contact Factory for service. | p.34 | |
| 4. The RF LED is not illuminated. | Verify that the RF signal strength (RSSI) is <0.2° VDC. | p.34 |
Owners and our team usually reply within a day — and your question helps the next person too.