Page 1 of the Foster LC125 user manual — LC125 /SM/07/04
Page 1 · click to enlarge
Page 1
Foster LC125 — LC125 diagram (page 1)
Fig. 1
Foster LC125 — LC125 diagram (page 1)
Fig. 2
Foster LC125 — LC125 diagram (page 1)
Fig. 3

LC125 MEATWELL

FREEZER

Foster LC125 — LC125 MEATWELL diagram (page 1)
Fig. 4

Foster Refrigerator Oldmedow Road Kings Lynn Norfolk PE30 4JU

Tel01553 691122 Fax: 01553 691447 Website: www.fosterrefrigerator.co.uk Email: sales@ foster-uk.com

a Division of ‘ITW (UK) Ltd’

LC125 /SM/07/04

Page 2 of the Foster LC125 user manual — lae
Page 2 · click to enlarge
Page 2

DISPOSAL REQUIREMENTS If not disposed of properly all refrigerators have components that can be harmful to the environment. All old refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in accordance with UK laws and regulations.

ContentsPage Introduction1 Technical Information1 Temperature Controller1 Controller Parameters2 Alarms and Warnings2 Electrical Connections2 Wiring Diagram3

Introduction Top loading meatwell for the storage of frozen products One piece foam shell with skin evaporator and bottom mount condensing system. R 134A refrigerant Fitted with corner bumpers to each side. Front smash bar as an option, fitted as standard for Burger King. Fitted with 4 x 60mm castors.

Temperature Set Point-21°C RefrigerantR134A Refrigerant Charge180 gms Capillary4.5mts x 042 Power supply230/50/1

Temperature Controller When the controller is switched on a single line appears on the display for 3 seconds to indicate the autotest period. After this period the air temperature measured by the T1 probe is displayed. It is strongly advised that before adjusting any Service Parameters a thorough understanding of the following instructions should be obtained.

lae

Check temperature set point.

Check set point by pressing the button

To increase set point press +

To decrease set point press +

Factory Temperature Set Point -21°C.

Exit from set up occurs after 10 seconds if no button is pressed.

Controller Set Up. The parameters are accessed by pressing the following keys in succession + + and keeping them pressed for 3 seconds. Access to the parameters has been achieved with the first parameter SCL being displayed.

To pass from one parameter to the next press either the or key.

To display the value press.

To change the value press + to increase, or + to decrease.

Show 10 more labels / short text on this page
LDU 15 Controller · aux · set · aux · set · set · set · set · set · set set
Page 3 of the Foster LC125 user manual — Controller Parameters
Page 3 · click to enlarge
Page 3

Controller Parameters

DisplayParameterLDU151E-B Default ValuesLC 125 SCLReadout Scale2°C2°C SPLMinimum Temperature Set Point05-25 SPHMaximum Temperature Set Point01-15 SPEffective Temperature Set Point03-21 HYSHysteresis3+3 CRTCompressor Rest Time (minutes)100 CDCCompressor Regulation with T1 Fail207 DFRDefrosting Frequency (/24 hours)40 DTODefrosting Duration (minutes)2020 DDYDefrost Display Control11 ATLLow Alarm Differential-5-10 ATHHigh Alarm Differential510 ATDTemperature Alarm Delay (minutes)6090 ACCCondenser Clean Interval050 OAUAuxiliary Output Mode of Operation30NON BAUAuxiliary Button Mode of Operation05NON OS1T1 Offset0000 SIMDisplay Slowdown0000 ADRAddress0101
HIHigh Temperature Alarm LOLow Temperature Alarm E1T1 Probe Failure DFDefrosting in Progress CLNCondenser

LDU 151E-BG Electrical Connections

DATA AUX T1 1 2 3 4 5 6 7 8 9 10 11 1234567891011 PWR
Foster LC125 — Controller Parameters diagram (page 3)
Fig. 5 · Controller Parameters
ITEMDescriptionPart Number Temperature ControllerLDU 151E-BG00-555357 Air ProbeT1POA Rocker Switch15243562 Rocker Switch Cover15243609 Capillary4.5 mts X 042"16010654 (sold in 5m lengths) CompressorGL60AA15427002 Drier1/4 DBL ENT1/4 OUT R13415480908 Condenser15432001 Condenser Fan MotorGrid Mount 5W15470032 Corner Bumpers15260653 Front Smash Bar00-744880-01 Castor60mm Swivel00-555335 Castor60mm Swivel Braked00-555336
Foster LC125 — Controller Parameters diagram (page 3)
Fig. 6 · Controller Parameters

Alarms and Warnings

Page 4 of the Foster LC125 user manual — Controller Parameters
Page 4 · click to enlarge
Page 4
Foster LC125 — Controller Parameters diagram (page 4)
Fig. 7 · Controller Parameters

Wiring Diagram

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Foster LC125

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Foster LC125

Be the first to ask — other owners or our team will answer.

Original document

Foster LC125 manual PDF

4 pages·188 KB·Freezer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…