EN
Foster logo
Official user manual

Foster BQCF 40

19 pages·573 KB·Freezer·PDF·ENDEFRITNLJA
Foster BQCF 40
Table of Contents 19 sections QC 11 & QC 600 · Blast Chiller · & BQCF 40 Chill / Freeze · Bakery Cabinet · … ShowHide
Page 1 of the Foster BQCF 40 user manual — QC 11 & QC 600
Page 1 · click to enlarge
Page 1
Foster BQCF 40 — QC 11 & QC 600 diagram (page 1)
Fig. 1

QC 11 & QC 600

Blast Chiller

& BQCF 40 Chill / Freeze

Bakery Cabinet

Foster BQCF 40 — QC 11 & QC 600 diagram (page 1)
Fig. 2
Page 2 of the Foster BQCF 40 user manual — QC 11 & QC 600
Page 2 · click to enlarge
Page 2
ContentsPage Introduction2 Model Details2 QC 11 & QC 600 BQCF 40 Blast Chill Operating Instructions3 Controller operating instructions4 LED’s and there meanings4 Program function and operation.5 Cycle Parameter Definitions.5 Cycle Parameter Access5 QC 11 Cycle Parameters.5 to 6 QC 600 Cycle Parameters.6 BQCF 40 Cycle Parameters.6 to 7 Function Menu7 to 8 Parameter Access and modification8 Parameter Settings8 to 9 Parameter Definitions9 to 11 Printer Management11 Alarm Signals11 Controller Electrical Connections11 Technical Data12 Wiring Diagram Numbers12
Page 3 of the Foster BQCF 40 user manual — QC 11 & QC 600
Page 3 · click to enlarge
Page 3

Introduction.

Cook Chill Operation. Blast chilling is a process to reduce the temperature of cooked food by swiftly arresting the cooking process, locking in its colour, flavour, texture and nutritional value. Department of health guidelines state that to safely blast chill food the temperature must be reduced from +70°c to +3°c within 90 minutes. Pre Chill ensures the correct cabinet temperature in the unit before chilling commences therefore improving the chilling performance.

Program 1 Soft Chilling. Soft chilling is the process of rapid but gentle chilling of food. This cycle brings down the food temperature to +3°c in no more than 90 minutes without the air or food temperature going below +2°c. This prevents large ice crystals forming therefore maintaining the texture, consistency and appearance of food such as vegetables, rice, pasta, custard and fruit with no dehydration or cell damage.

Program 2 Hard Chilling Time. Hard chilling is the process of general purpose chilling using time. This cycle brings down the food temperature to +3°c in no more than 90 minutes and is ideal for chilling meat pies, lasagne, pasta and individually portioned meals. The air temperature for this process goes down to -15°c for the first 70 minutes of the cycle, to extract the maximum amount of heat from the product quickly. The air temperature then increases to +2°c for the final 30 minutes of the time to reduce surface damage and ensure quality.

Program 3 Hard Chill + This program is for specialist chilling only and not recommended for normal use.

Program 4 Hard Chilling Temperature. Hard chilling is the process of general purpose chilling using the food probe. This cycle brings down the food temperature to +3°c in no more than 90 minutes and is ideal for chilling meat pies, lasagne, pasta and individually portioned meals. The air temperature for this process goes down to -15°c for the first 70% of the cycle, to extract the maximum amount of heat from the product quickly. The air temperature then increases to +2°c for the final 30% of the time to reduce surface damage and ensure quality.

Longer Term Storage – ‘Hold’ Mode (Conservation) Upon the completion of the blast chilling cycle the controller will automatically enter the ‘Hold’ mode. This will either be because the selection set time has elapsed or the product core temperature has been achieved. When the hold period commences an alarm will sound for a period denoted in the service operating parameters. The controller will determine the temperature to be maintained during the hold phase based on the chilling or freezing cycle that has been completed. If a soft or hard chill has taken place the controller will maintain an air temperature of 2°c, if a freeze program is completed the air temperature of -21°c will be maintained. The hold mode is principally intended as a temporary storage facility offering the operator flexibility until the product can be unloaded into a longer term storage units at the correct storage temperature. On occasion this hold period may become extended to operate overnight or to provide emergency refrigeration backup. In such instances defrosting would automatically occur as necessary.

Model Details.

Cabinet Blast Chiller & Freezers. Controls located in the unit cover. All of the cabinet range incorporate a bottom mounted refrigeration systems with the evaporator located on the back wall. The refrigerant used is R404a. Door operated fan switches stop the fans when the door is opened. QC11, QC 600 all 230/1/50Hz 13amp.

QC11: Economy Blast Chiller, 11kg capacity with three GN1/1 shelves. QC 600: Economy Blast Chiller, 40kg capacity BQF 40: Bakery Quick Freeze,

Page 4 of the Foster BQCF 40 user manual — QC 11, QC 600 & BQCF 40 Blast Chill Operating Instructions. Operation
Page 4 · click to enlarge
Page 4

QC 11, QC 600 & BQCF 40 Blast Chill Operating Instructions. Operation

When mains electrical power is first applied to the controller it will carry out a self-test function - - - for approximately 3 seconds, after this the cabinet air temperature will be displayed. To start, select the program required by pressing the program mode button (1, 2, 3,4), the LED for that mode will

illuminate, press and hold start key

for three seconds to start the program. The display will show the program time. The compressor may pause before starting at the start of a cycle to prevent short cycling of the condensing system and is normal.

When the time or temperature is achieved the machine will go in to the Hold mode with the sounding of an alarm.

To stop the cycle press and hold the start key

for 2 seconds, the cycle will be terminated.

Manual Defrost.

When the blast chiller is in hold press the defrost key

and hold for 2 seconds to start the defrost. When defrost is complete the machine will revert to the hold temperature.

Foster BQCF 40 — QC 11, QC 600 & BQCF 40 Blast Chill Operating Instructions. Operation diagram (page 4)
Fig. 3 · QC 11, QC 600 & BQCF 40 Blast Chill Operating Instru…
Program ModeProgram TypeProgram TimeAir TemperatureChill TemperatureHold Temperature SOFT9090 minutes @ +2°cN/A+3°c HARD9070 minutes @ -15°cN/A+3°c 20 minutes @ +2°c HARD +240240 minutes @ -15°cN/A+3°c HARD75% @ -15°c75% @ -6°c+3°c 25% @ +3°c25% @ +2°c

Introduction There are four main programmes that you will need to use your Blast Chiller.

Soft Chill- for the safe chilling of delicate products.

Hard Chill Time - For general purpose chilling based on time.

Hard Chill +-. This program is for specialist chilling only and is not recommended for normal use.

Hard Chill Temperature - For general purpose chilling using the food probe.

Guide for Blast Chilling

Food TypeIncludesBlast Chill Programme required MeatBeef, pork, lamb, poultry & mince2 or 4 FishFried, poached or baked – haddock, plaice, salmon, cod fillets etc1 Prepared dishesStews & casseroles, lasagne, risotto, shepherds pie2 or 4 Vegetables & PulsesSteamed or roasted veg, rice and potatoes etc.1 FruitStewed and cooked fruits.1 BakeryCakes2 or 4 BakeryPastries2 or 4 DessertsFruit Based desserts & egg based flans.1 DessertsSponge puddings and dense desserts such as cheesecake.2 or 4
Foster BQCF 40 — QC 11, QC 600 & BQCF 40 Blast Chill Operating Instructions. Operation diagram (page 4)
Fig. 4 · QC 11, QC 600 & BQCF 40 Blast Chill Operating Instru…
Page 5 of the Foster BQCF 40 user manual — DOWN SET
Page 5 · click to enlarge
Page 5

Controller operating instructions

Foster BQCF 40 — Controller operating instructions diagram (page 5)
Fig. 5 · Controller operating instructions

DOWN SET

Display Set Point: Press the SET key whilst in the HOLD Mode will display the set point for 5 seconds.

Modify Set Point: Press and hold the SET key for 2 seconds. The SET point will be displayed and the LED’s of the first and third digits will blink. To change the value, press the UP key to increase the value or the DOWN key to decrease. To store the new value either press the SET key or wait for the controller to return to displaying air temperature.

Manual Defrost: Press and hold the DEFROST/UP key for 2 seconds to initiate a manual defrost.

Starting the cycle: Press and hold the START/STOP key for 3 seconds.

Temporarily Stopping the Cycle:

Press and release the START/STOP key.

The condensing system will stop and the message “Stb” will be displayed.

To restart the cycle press and release the START/STOP key for the cycle to continue from the point it was interrupted. Alternatively the cycle will restart automatically after the time set in parameter PAU (see parameter list on page ).

Stopping the Cycle: Press and hold the START/STOP until the display shows “End”, the buzzer will sound and the unit will enter the stand by mode.

LED’s and there meanings A series of LED’s, number 1 to 4, on the front panel are used to indicate certain functions controlled by the controller. There functions are listed below.

LEDModeFunction 1IlluminatedCompressor Enabled 1FlashingProgramming Phase (flashing with LED 2). 1FlashingAnti Short Cycle Enabled 2IlluminatedFan/s Enabled 2FlashingProgramming Phase (flashing with LED 1). 2FlashingActivation Delay Active 3IlluminatedDefrost Active 3FlashingDrip Time Active 4IlluminatedFreezing Cycle or Hold Mode Active 4FlashingInstrument Temporarily Stopped 5IlluminatedAlarm Signalling
Foster BQCF 40 — DOWN SET diagram (page 5)
Fig. 6
Page 6 of the Foster BQCF 40 user manual — Controller operating instructions
Page 6 · click to enlarge
Page 6

5 Illuminated When in program Pr2 indicates the parameter is also present in Program function and operation.

Each of the programs is divided into 3 phases of operation.

Phase 1: Hard Chill. Phase 2: Soft Chill. Phase 3: Freezing Cycle.

For each phase there are 3 parameters. IS1 (iS2, iS3): operation controlled by the Food Probe. RS1 (rS2, rS3): set point for the room Temperature Probe for each phase. Pd1 (Pd2, Pd3): The maximum time duration for each phase. Hds: hold phase set point at the end of the whole cycle.

There are also 2 parameters relating to defrost. These are dbC = Defrost Before cycle, dbH = defrost before hold (at the end of the cycle).

Cycle Parameter Definitions.

Parameter Range Minimum Description dbc: yes/ no Defrost before cycle First Phase iS1 50 to + 50°C 1°C or 1°F Food Probe Set Point (when the temperature measured by the food probe reaches this value the first phase is ended). rS1 50 to + 50°C 1°C or 1°F Air Temperature Set Point (prevents the air temperature going to low during the first phase). Pd1 OFF to 4.0 hours 10 minutes Maximum Time For The First Phase Second Phase iS2 50 to + 50°C 1°C or 1°F Food Probe Set Point (when the temperature measured by the food probe reaches this value the second phase is ended). rS2 50 to + 50°C 1°C or 1°F Air Temperature Set Point (prevents the air temperature going to low during the first phase). Pd2 OFF to 4.0 hours 10 minutes Maximum Time For The Second Phase Third Phase iS3 50 to + 50°C 1°C or 1°F Food Probe Set Point (when the temperature measured by the food probe reaches this value the whole cycle is ended). rS2 50 to + 50°C 1°C or 1°F Air Temperature Set Point (prevents the air temperature going to low during the third phase). Pd3 OFF to 4.0 hours 10 minutes Maximum Time For The Third Phase.

dbH yes/ no Defrost before the hold phase HdS 50 to + 50°C or OFF 1°C or 1°F Set Point OF The Hold Phase. If set to OFF the hold Phase is disabled. Important Note: If the duration time phase is set to OFF the corresponding phase is disabled. E.G. If Pd3 = OFF the third phase of the cycle is not active.

Cycle Parameter Access To access the cycle parameters Press and Hold the Set and Down buttons for 2 seconds. The display will show “Prb” press the down button and scroll through until you get to “FCY” cycle management. Press Set “Cy1” will be displayed, press the down button to scroll through the submenu to select the required cycle parameters. Once selected press the set key to access the cycle parameters.

QC 11 Cycle Parameters.

Soft Chill- for the safe chilling of delicate products. (Cy1)

dbC = noiS1 = -10°CiS2 = 5°CiS3 = 3°CdbH = no rS1 = 2°CrS2 = -2°CrS3 = -2°CHdS = 3°C Pd1 = 1.3 hoursPd2 = OFFPd3 = OFF
Page 7 of the Foster BQCF 40 user manual — Controller operating instructions
Page 7 · click to enlarge
Page 7
Page 7 of the Foster BQCF 40 user manual — Controller operating instructions
Page 8 of the Foster BQCF 40 user manual — Controller operating instructions
Page 8 · click to enlarge
Page 8

Hard Chill Time - For general purpose chilling based on time. (Cy2)

dbC = noiS1 = -15°CiS2 = 2°CiS3 = -18°CdbH = no rS1 = -15°CrS2 = 2°CrS3 = -30°CHdS = 3°C Pd1 = 1.1hoursPd2 = 0.2 hoursPd3= OFF

Hard Chill +-. This program is for specialist chilling only and is not recommended for normal use. (Cy3)

dbC = noiS1 = -15°CiS2 = -18CiS3 = -18°CdbH = no rS1 = -15°CrS2 = -30°CrS3 = -15°CHdS = 3°C Pd1 = 4 hoursPd2 = OFFPd3 = OFF

Hard Chill Temperature - For general purpose chilling using the food probe. (Cy4)

dbC = noiS1 = -6°CiS2 = 3°CiS3 = -18°CdbH = no rS1 = -15°CrS2 = 2°CRS3 = -30°CHdS = 3°C Pd1 = 1.1 hoursPd2 = 0.2Pd3 = OFF

QC 60 Cycle Parameters.

Soft Chill- for the safe chilling of delicate products. (Cy1)

dbC = noiS1 = -10°CiS2 = 5°CiS3 = 3°CdbH = no rS1 = 2°CrS2 = -2°CrS3 = -2°CHdS = 3°C Pd1 = 1.3 hoursPd2 = OFFPd3 = OFF

Hard Chill Time - For general purpose chilling based on time. (Cy2)

dbC = noiS1 = -15°CiS2 = 2°CiS3 = -18°CdbH = no rS1 = -15°CrS2 = 2°CrS3 = -30°CHdS = 3°C Pd1 = 1.1hoursPd2 = 0.2 hoursPd3= OFF

Hard Chill +-. This program is for specialist chilling only and is not recommended for normal use. (Cy3)

dbC = noiS1 = -15°CiS2 = -18CiS3 = -18°CdbH = no rS1 = -15°CrS2 = -30°CrS3 = -15°CHdS = 3°C Pd1 = 4 hoursPd2 = OFFPd3 = OFF

Hard Chill Temperature - For general purpose chilling using the food probe. (Cy4)

dbC = noiS1 = -6°CiS2 = 3°CiS3 = -18°CdbH = no rS1 = -15°CrS2 = 2°CRS3 = -30°CHdS = 3°C Pd1 = 1.1 hoursPd2 = 0.2Pd3 = OFF

BQCF 40 Cycle Parameters.

Foster BQCF 40 — Controller operating instructions diagram (page 8)
Fig. 7 · Controller operating instructions

Soft Chill- for the safe chilling of delicate products. (Cy1)

dbC = noiS1 = -10°CiS2 = 5°CiS3 = 3°CdbH = no rS1 = 2°CrS2 = -2°CrS3 = -2°CHdS = 3°C Pd1 = 1.3 hoursPd2 = OFFPd3 = OFF

Hard Chill Time - For general purpose chilling based on time. (Cy2)

dbC = noiS1 = -15°CiS2 = 2°CiS3 = -18°CdbH = no rS1 = -15°CrS2 = 2°CrS3 = -30°CHdS = 3°C Pd1 = 1.1hoursPd2 = 0.2 hoursPd3= OFF
Page 9 of the Foster BQCF 40 user manual — Function Menu
Page 9 · click to enlarge
Page 9

Hard Chill +-. This program is for specialist chilling only and is not recommended for normal use. (Cy3)

dbC = noiS1 = -6°CiS2 = 3°CiS3 = -18°CdbH = no rS1 = -15°CrS2 = 2°CrS3 = -30°CHdS = 3°C Pd1 = 1.1 hoursPd2 = 0.2Pd3 = OFF

Hard Chill Temperature - For general purpose chilling using the food probe. (Cy4)

dbC = noiS1 = -6°CiS2 = 3°CiS3 = -18°CdbH = no rS1 = -15°CrS2 = 2°CRS3 = -30°CHdS = 3°C Pd1 = 1.1 hoursPd2 = 0.2Pd3 = OFF

Function Menu

To access the cycle parameters Press and Hold the Set and Down buttons for 2 seconds. The display will show “Prb”.

  • Prb: Probe Display. Allows the probe temperatures to be displayed for ten seconds.
  • rPr: Displays temperature measured by the AIR probe.
  • Epr: Displays temperature measured by the EVAPORATOR probe.
  • IPr: Displays temperature measured by the FOOD probe.

Press SET to display the reading of the selected probe, press SET with the reading displayed returns to the probe labels.

Probe Fault Identification. rPF = AIR probe fault. EPF = EVAPORATOR probe fault. iPF = Food probe fault.

Pr1: User Parameters. Includes all user accessible parameters. If no parameters are present in the menu “Pr2” will be displayed.

Pr2: Installer Parameters. Includes all the instrument parameters (at installer level). It can only be accessed using the security code. On entering the parameters it is possible to modify all parameters and add or remove parameters from “Pr1” (user level) by pressing “SET” + “UP”. When a parameter is enabled at user level, LED 5 (Alarm LED) is on.

Fcy: Cycle Managent. The Fcy menu contains the Cy1, Cy2, Cy3 and Cy4 sub menus. Each of the sub menus should be set to the Standard Cycle Parameters as detailed on pages 6 and 7.

Sto: Cycle Length. The “Sto” menu records the real length of a cycle and the real length of each single phase. It contains the following sub menu: tCy: Cycle Duration. tP1: First Phase Duration. tP2: Second Phase Duration. tP3: Third Phase Duration.

rtC: Clock Managent. Real time clock parameters. SEC: Seconds (00 to 59). Min: Minutes (00 to 59). Hou: Hours (1 to 24). 7dY: Day of the week (Mon = Monday. tue = Tuesday. Wed = Wednesday. Thu = Thursday. Fri = Friday. Sat = Saturday. Sun: Sunday) dAY: Day of the Month (1 to 31). Mon: Number of the month (1 to 12). YEA: Year (0 to 99). Alr: Alarms Display. This function displays any alarm messages.

Prt: Printer Management. Contains the parameters for the management of the printer.

Page 10 of the Foster BQCF 40 user manual — Parameter Settings
Page 10 · click to enlarge
Page 10

PrP: Printer presence. (Yes or no) Enables or disables the printer. ItP: Printing interval. (0.0 to 30.0). Sets the print interval. PbP: Print probe selection. (iP: only the food probe selected. rP: only the air probe selected. irP: Food and Air probe selected. irE: All probes selected). PtH: (yes or no) Enables or disables the printing during the holding phase.

tSt: Starts the controller self test function.

Out: Exit from the menu.

Parameter Access and modification To access the parameters firstly enter the function menu by pressing the “SET” and “DOWN” keys for 3 seconds. Scroll through the labels and select “PR2”, press the “SET” key. “PAS” label flashes for a few second followed by “0 _ _” with the zero flashing. The access code is ‘ 321’. Use the “UP” or “DOWN” key to input the first number of the security code in the flashing section, confirm by pressing “SET”. Repeat the operation for the second and third digits. If the security code is correct “Hy” will be displayed. NOTE: if no key is pressed for 15 seconds the controller reverts to displaying the room temperature.

Parameter Settings

LabDescriptionDefaultQC 11QC 600BQCF 40 Regulation Hydifferential3333 ACAnti-short cycle delay2222 1c2Second compressor configuration0000 rPOThermostat probe calibration0000 EPPEvaporator probe presenceYESNOYESYES EPOEvaporator probe calibration0000 iPPInsert probe presenceYESYESYESYES iPOInsert probe calibration0000 CFTemperature measurement unit°C°C°C°C rESResolution (for °C):ININININ PAUTime of stand by1111 PFtMaximum acceptable duration of power failure2222 iPdTemperature difference for the automatic recognition of the insert probe3333 iPtTime delay for the automatic recognition of the insert probe60606060 ConCompressor ON time with faulty probe15151515 COFCompressor OFF time with faulty probe10101010 diCDigital input operating modedordordorDor diPDigital input polarityOPOPOPOP didDigital input delay5555 OACAuxiliary output configurationALALALAL OAPAuxiliary output polarityOPCLCLCL OAtAUX output timer60606060 OASSet point for AUX output0000 OAHDifferential for AUX output2222 OAiProbe selection for the AUX outputrPrPrPrP Defrost tdFDefrost typeinininIn dPODefrost before holding cycleYESYESYESYES IdFInterval between defrost cycles6.06.06.06.0 dtEDefrost termination temperature20202020 MdFMaximum length for defrost20202020 dFdTemperature displayed during defrostrtrtrtRt FdtDrip time1111 Fans FnCFan operating modec nO YO YO Y FStFan stop temperature_ 30_ 30_ 30_ 30 AFHDifferential for the stop temperature and for the alarm2222 FndFan delay after defrost2222
Page 11 of the Foster BQCF 40 user manual — Parameter Definitions
Page 11 · click to enlarge
Page 11
Foster BQCF 40 — Parameter Definitions diagram (page 11)
Fig. 8 · Parameter Definitions
Alarm ALUMAXIMUM temperature alarm30303030 ALLMinimum temperature alarm30303030 ALdTemperature alarm delay60606060 EdAAlarm delay after defrost30303030 tbASilencing alarm relayYESYESYESYES Others Ad1Address 1 for RS485:0000 Ad2Address 2 for RS4851111 LodLocal displaynrnrnrnr rEdRemote displayiPiPiPIP LOCKeypad LOCKnononoNo PASSecurity code set up321321321321 tPbType of probentcntcntcNtc rELRelease code (readable only)1,01.01.01.0 PtbParameter code (readable only)--------

Parameter Definitions

REGULATION HyIntervention differential for set point: (0,1 ÷ 12,0 /0,1°C/1°F), always positive. Compressor cut IN is Set Point

Plus Differential (Hy). Compressor cut OUT is when the temperature reaches the set point. AC Anti-short cycle delay: (0÷30 min) minimum interval between the compressor stop and the following restart. 1c2 Second compressor setting: (enabled only if OAC=C2) The fourth relay work as second compressor if OAC=Co2. Second compressor operates on set + OAS. (whit set= set loaded during the current phase). It starts oAt min. after the first compressor The following table shows how it works:

Foster BQCF 40 — Parameter Definitions diagram (page 11)
Fig. 9 · Parameter Definitions
CycleHolding 1c2=0C1 ON; C2 OnC1 on; C2 On 1c2=1C1 on; C2 OnC1 on C2 off 1c2=2C1 on; C2 offC1 on; C2 On 1c2=3C1 on; C2 offC1 off; C2 On

rPO Thermostat probe calibration (-12,0 ÷ 12,0; res. 0,1 °C /1°F) EPP Evaporator probe presence (not present in the XB350C): (no / YES) no: not present (timed defrost); YES:

present (end defrost ) EPO Evaporator probe calibration (not present in the XB350C): (-12,0 ÷ 12,0; res. 0,1 °C /1°F) iPP Insert probe presence (no / YES) no: not present; YES: present. iPO Insert probe calibration (-12,0 ÷ 12,0; res. 0,1 °C /1°F) CFTemperature measurement unit: °C =Celsius; °F =Fahrenheit rES Resolution (for °C): in: integer; de: with decimal point PAU Time of stand by: (0 ÷ 60min) after this time the controller restart the cycle PFt Maximum acceptable duration of power failure: (0 ÷ 250 min) if power failure duration is less than PFt, the cycle restarts from the same point at which it was stopped otherwise the cycle restarts from the beginning of the current phase. iPd Temperature difference for the automatic recognition of the insert probe: (0 ÷ 30; ris.1 °C/1°F) if the difference of temperature between the insert probe and the thermostat probe is less than iPd, the selected cycle is made by time. iPtTime delay for the automatic recognition of the insert probe: (0÷255sec, with 0 only timed cycles are done)

time between the start of a cycle and the comparison of the temperature of the thermostat probe and the insert probe to recognising if the insert probe is used. Con Compressor ON time with faulty probe: (0÷ 255 min) time during which the compressor is active in case of

faulty thermostat probe. With COn=0 compressor is always OFF COF Compressor OFF time with faulty probe: (0÷255 min) time during which the compressor is off in case of

faulty thermostat probe. With COF=0 compressor is always active diC Digital input operating mode (EAL, bAL, dor) EAL: external alarm; bAL: serious alarm; dor: door open function diP: digital input polarity: (OP÷CL)select if the digital input is activated by opening or closing the contact. OP=

opening; CL=closing did: digital input delay (0÷255 min) delay between digital input activation and his signalling for configurable or

door opened alarm. NOTE: with diC=EAL did has to be different from zero.

Page 12 of the Foster BQCF 40 user manual — Parameter Definitions
Page 12 · click to enlarge
Page 12
OACAUX output configuration: (AL, Li, UL, Ip, AA, rE, dF, C2)

AL: alarm output; Li: light of the cabinet; UL: for the ultra-violet light (It is actionable only when the controller is in OFF position); Ip: to extract the insert probe (It is actionable only when the controller is in OFF position); AA: anti - condensation; rE: the IV relay works as a thermostat, with direct action (cooling) (OAH>0), and inverse actions (heating) (OAH

of the auxiliary, with OAH0 it is for cooling. COOLING: AUX cut IN is OAS Plus Differential (OAH>0). AUX cut OUT is when the temperature reaches the set point OAS. HEATING: AUX cut IN is OAS Plus Differential (OAH

point OAS. OAi Probe selection for the AUX output (rP, EP, iP) rP = thermostat probe, EP = evaporator probe; iP = insert probe

DEFROST tdF Defrost type (not present in the XB350C): (rE= electrical heater; in = hot gas). dPO Defrost before the holding: no= no defrost; YES= defrost at the start of a holding cycle. IdF Interval between defrost cycles: (0.1÷ 24.0; res. 10 min) Determines the time interval between the beginning of two defrost cycles. (with 0.0 the defrost is disabled) dtE Defrost termination temperature (not present in the XB350C): (-50÷50 °C/°F) Sets the temperature measured by the evaporator probe, which terminates the defrost. MdF Maximum length for defrost: (0÷255 min) When EPP = no (timed defrost) it sets the defrost duration, when

EPP = YES (defrost termination based on temperature) it sets the maximum length for defrost. dFd Temperature displayed during defrost: (rt , it, SEt, dEF) rt: real temperature; it: temperature at the start of defrost; SEt: set point; dEF: “dEF” message Fdt Drip time (not present in the XB350C): (0 ÷ 60 min) Time interval between reaching defrost termination temperature and the restoring of the controllers' normal operation. This time allows the evaporator to eliminate water drops that might have formed during defrost.

FANS FnC Fans operating mode during the holding phase:

C-n= runs with the compressor, OFF during defrost; o-n = continuous mode, OFF during defrost; C-Y = runs with the compressor, ON during defrost; o-Y = continuous mode, ON during defrost; FSt Fan stop temperature: (-50÷50°C/°F; res. 1°C/1°F) if the temperature, detected by the evaporator probe is above FSt fans are stopped. It serves to avoid blowing warm air around the room. AFH Differential for the stop temperature and for the alarm (0.1 ÷ 25.0 °C; ris.0.1°C/1°F) Fans carry on working

when the temperature reaches the FSt-AFH value, the temperature alarm recovers when the temperature is AFH degrees below the alarm set. Fnd Fan delay after defrost: (0 ÷ 255 min) The time interval between end of defrost and evaporator fans start.

ALARM ALU MAXIMUM temperature alarm(1 ÷ 50 °C/°F) When the “SET+ALU” temperature is reached the alarm is

enabled, (possibly after the “Ald” delay time). ALL Minimum temperature alarm: (1÷50°C/1°F) When the “SET-ALL” temperature is reached the alarm is

enabled, (possibly after the “Ald” delay time). ALd Temperature alarm delay: (0÷255 min) time interval between the detection of an alarm condition and alarm

signalling. EdA Temperature alarm delay at the end of defrost: (0 ÷ 255 min) Time interval between the detection of the

temperature alarm condition at the end of defrost and alarm signalling. tbA Silencing alarm relay: (Yes= silencing buzzer and alarm relay, no= only buzzer silencing).

OTHER Ad1 Address 1 for RS485: (0 ÷ 94) Ad2 Address 2 for RS485 (0 ÷ 94) Lod: Local display: (rP, EP, iP, nr) Select which probe is displayed by the instrument. rP: Thermostat probe. EP: Evaporator probe. iP: Insert probe, nr: During a temperature cycle the insert probe is displayed, during the holding phase the room probe is displayed. If the cycle is made by time the time remaining is displayed (in minutes). rEd Remote display: (rP, EP, Ip) select which probe is displayed by the XR REP. rP: thermostat probe; EP: evaporator probe; iP: insert probe. Loc Set point of the holding phase lock (no - YES) It locks the set point of the holding phase.

Page 13 of the Foster BQCF 40 user manual — Controller Electrical Connections
Page 13 · click to enlarge
Page 13

PAS Security code set up: (0 ÷ 999) tPb Type of probe: it displays the probe used (NTC or PTC) (readable only) rEL Release code (readable only) Ptb Parameter code (readable only)

Printer Management The instrument XB570L can drive the serial printer XB05PR by means of the RS232 output. So temperatures measured during a freezing cycle can be printed. The internal Real Time clock of the instrument provides time reference. The “Prt” functions manages the printer by means of the following parameters: Prt: printer presence: (Yes/no) it enables or disables the printer. itP: printing interval: (0.0÷30.0 min). PbP: which probe has to be printed: (iP: Only the insert probe; rP: Only the thermostat probe; irP: Insert and thermostat probes; irE: All the probes. PtH: Printing during the holding phase (yES, no) yES = Printing enabled during the holding phase; no = Printing disabled during the holding phase.

Alarm Signals

Mess. Cause Outputs “EE” Data or memory failure Alarm output ON; Other outputs unchanged

“rPF” Thermostat Probe failure Alarm output ON; Compressor output according to parameters “COn” and “COF”

“EPF” Evaporator Probe failure Alarm output ON; Defrost termination is timed; No temperature control on fans.

“iPF” Insert probe failure Alarm output ON; Other outputs unchanged; The cycle is made by time “rtC” Real Time Clock data lost Alarm output ON; Other outputs unchanged;

“rtF” Real Time Clock failure Alarm output ON; Other outputs unchanged; The date and the duration of the cycle are not available. “HA” Maximum temperature alarm Alarm output ON; Other outputs unchanged. “LA” Minimum temperature alarm Alarm output ON; Other outputs unchanged.

“FF” Fast freezing interrupted by short power failure Alarm output ON; The freezing cycle restart from the same point at which was interrupted. “PFA” Fast freezing interrupted by long power failure Alarm output ON; The freezing cycle restart from the current phase.

“OCF” Max duration of the cycle is expired Alarm output ON; Other outputs unchanged. In any case the cycle ends when the final temperature is reached “EA” External alarm Alarm output ON; Other outputs unchanged. “CA” Serious external alarm Alarm output ON; Other outputs OFF. “dA” Door open alarm Alarm output ON; Other outputs unchanged.

Controller Electrical Connections

Foster BQCF 40 — Controller Electrical Connections diagram (page 13)
Fig. 10 · Controller Electrical Connections
Page 14 of the Foster BQCF 40 user manual — Wiring Diagram Numbers
Page 14 · click to enlarge
Page 14

Technical Data

Foster BQCF 40 — Technical Data diagram (page 14)
Fig. 11 · Technical Data

QC11 QC600 BQF 40 Nominal Chilling Capacity 11Kg 40Kg Duty @ -15°C 830w 1031w Fans 1 2 Defrost Load N/A N/A Evaporating Temperature -15°C -15°C Refrigerant Control TEV TEV Refrigerant R404a R404a Refrigerant Quantity 1000g TBA Electrical Supply 230/1/50 – 13amp 230/1/50 – 13amp Total Heat Rejection 1500w 2080w

Wiring Diagram Numbers

Foster BQCF 40 — Wiring Diagram Numbers diagram (page 14)
Fig. 12 · Wiring Diagram Numbers

Model Wiring Diagram Number Fuse Rating QC 11 01-233728 13 Amp QC 600 01-233729 13 Amp BQCsF 40 13 Amp

Page 15 of the Foster BQCF 40 user manual — QC 11 Wiring Diagram
Page 15 · click to enlarge
Page 15
Foster BQCF 40 — QC 11 Wiring Diagram diagram (page 15)
Fig. 13 · QC 11 Wiring Diagram

QC 11 Wiring Diagram

Page 16 of the Foster BQCF 40 user manual — QC 600 Wiring Diagram
Page 16 · click to enlarge
Page 16
Foster BQCF 40 — QC 600 Wiring Diagram diagram (page 16)
Fig. 14 · QC 600 Wiring Diagram

QC 600 Wiring Diagram

Page 17 of the Foster BQCF 40 user manual — BQCF 40 Wiring Diagram. Sheet 1 of 2
Page 17 · click to enlarge
Page 17
Foster BQCF 40 — BQCF 40 Wiring Diagram. Sheet 1 of 2 diagram (page 17)
Fig. 15 · BQCF 40 Wiring Diagram. Sheet 1 of 2

BQCF 40 Wiring Diagram. Sheet 1 of 2

Page 18 of the Foster BQCF 40 user manual — BQCF 40 Wiring Diagram. Sheet2 of 2
Page 18 · click to enlarge
Page 18
Foster BQCF 40 — BQCF 40 Wiring Diagram. Sheet2 of 2 diagram (page 18)
Fig. 16 · BQCF 40 Wiring Diagram. Sheet2 of 2

BQCF 40 Wiring Diagram. Sheet2 of 2

Page 19 of the Foster BQCF 40 user manual — BC11 BC600/SM/08/04
Page 19 · click to enlarge
Page 19
Foster BQCF 40 — BC11 BC600/SM/08/04 diagram (page 19)
Fig. 17

France Foster Refrigerator France SA Tel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: commercial@fosterfrance.com

Germany Foster Refrigerator Gmbh, Tel(49) 2333 839375. Fax (49) 2333 839377. Email: [email protected]

Foster Refrigerator Oldmedow Road Kings Lynn Norfolk PE30 4JU

Tel01553 691122 Fax: 01553 691447 Website: www.fosterrefrigerator.co.uk Email: sales@ foster-uk.com

a Division of ‘ITW (UK) Ltd’

BC11 BC600/SM/08/04

Foster European Operations

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Foster BQCF 40

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Foster BQCF 40

Be the first to ask — other owners or our team will answer.

Original document

Foster BQCF 40 manual PDF

19 pages·573 KB·Freezer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…