EN
Fortinet logo
Official user manual

Fortinet 2002F

2 pages·573 KB·Network Card·PDF·ENDEFRITNLJA
Fortinet 2002F
Table of Contents 27 sections QuickStart Guide · Configuring · FortiBridge-2002F · INT1 · … ShowHide
Page 1 of the Fortinet 2002F user manual — INT1
Page 1 · click to enlarge
Page 1
Fortinet 2002F — QuickStart Guide diagram (page 1)
Fig. 1 · QuickStart Guide
Fortinet 2002F — QuickStart Guide diagram (page 1)
Fig. 2 · QuickStart Guide

QuickStart Guide

Fortinet 2002F — QuickStart Guide diagram (page 1)
Fig. 3 · QuickStart Guide

Configuring

FortiBridge-2002F

2. Start a terminal emulation program (such as HyperTerminal) on the management computer. Use these settings: Baud Rate 9600, Data bits 8, Parity None, Stop bits 1, Flow Control None. 3. At the login: prompt, type admin and press Enter twice. (The login prompt is preceded by the server default host name.)

Use the following procedure to connect to the web-based manager for the first time. Configuration changes made with the web-based manager are effective immediately with out resetting the FortiBridge unit or interrupting service.

To connect to the web-based manager 1. Connect the management port of the FortiBridge unit to Ethernet port of the manage ment computer. Use a cross-over Ethernet cable to connect the devices directly. Use straight-through Ethernet cables to connect the devices through a hub or switch. 2. Configure the management computer to be on the same subnet as the FortiBridge management port interface. To do this, change the IP address of the management computer to 192.168.1.2 and the netmask to 255.255.255.0. 3. To access the FortiBridge web-based manager, in your browser, go to http://192.168.1.99 4. Type admin in the Name field and click Login.

To configure the FortiBridge unit using the CLI 1. Change the management IP address. config system manageip set ip / end

INT1

EXT1

INT3

EXT3

CONSOLE1

MODEM1 MGMT1

CONSOLE2 MODEM2 MGMT2

USB1

INT1

EXT1

HA1

BYPASS1

MODE1 RESET1

USB2

INT3

EXT3

HA2

BYPASS2

MODE2 RESET2

INT2

INT2

EXT2

EXT2

PWR1 NORMAL1

INT4

INT4

EXT4

EXT4

PWR2 NORMAL2

2. Configure the primary and secondary DNS server IP addresses. config system dns set primary set secondary end
3. Configure the default gateway. config system route edit 1 set gateway end

To configure Probes Probes monitor the FortiGate unit by sending packets from the INT 2 interface through the FortiGate unit to the EXT 2 interface. If probe packets are not received at the EXT 2 interface the FortiBridge unit detects a failure.

AC Power50 W, 100 - 240 VAC, 50 - 60Hz Chassis 1U Dimensions44.0 cm x 30.1 cm x 4.44 cm

Configure probe settings to set actions on failure, add a dynamic IP pattern used by the probe packets, and enter the serial number of the FortiGate unit. Actions on failure can include failing open and sending an alert email, a syslog message, and an SNMP trap.

4. Change the administrator password. config system admin edit admin set password end

4 1GB LC SFP (SX) Ingress/Egress ports

4 1GB SFP (SX) Ingress/Egress ports

1. Go to Probe > Settings . 2. Enter the Probe IP address pattern (#.#.#.*). 3. Enable ping, HTTP, FTP, POP3, SMTP, and/or IMAP probes. 4. Set the Port Number for each protocol. 5. Change the Failure Threshold and probe Interval for each probe.

2 10/100/1000 Management ports

Shutting down the FortiBridge unit

When powering off the FortiBridge unit, always shut down the unit using the following pro cedures before disconnecting the power supply. Not following this procedure can increase the risk of damaging the FortiBridge flash disk.

To set up Notifications 1. Go to Probe > Notifications. 2. Enter a Notification Message Tag. 3. Optionally, select the Syslog check box and enter the IP address, port and facility of the Syslog server that receives FortiBridge syslog messages. 4. Optionally, select the Email check box and enter the SMTP server, email addresses, SMTP user name, and password of the users to send the alert email. 5. Optionally, select the SNMP check box and enter the name, hosts, and traps of the SNMP manager to send alerts to a community.

To power off the FortiBridge unit 1. Go to System > Status. 2. In the Unit Operation area, click Shut Down. 3. Once the indicates the shut down procedure has completed, disconnect the FortiBridge unit from the power source.

To configure the Management, Default Gateway, and Primary and Secondary DNS server IP addresses 1. Go to System > Status > Management Port area and click Change.

To connect to the FortiBridge unit 1. Use a RJ-45 to DB-9 cable to connect the FortiBridge management port to the man agement computer serial port.

© Copyright 2010 Fortinet Incorporated. All rights reserved. Products mentioned in this document are trademarks or registered trademarks of their respective holders. Regulatory Compliance FCC Class A Part 15, UL/CB/CUL, C Tick, VCCI 11 May 2010

Visit these links for more information and documentation for your Fortinet product:

Technical Documentation - http://docs.fortinet.com Fortinet Knowledge Center - http://kb.fortinet.com Technical Support - http://support.fortinet.com Training Services - http://campus.training.fortinet.com

Show 10 more labels / short text on this page
Web-based Manager · FortiBridge 2002F · FortiGate · FortiGate · Network Interfaces · 2 USB connections · 2 Console ports · 2 Modem connections · Command Line Interface · 01-410-124834-20100511
Page 2 of the Fortinet 2002F user manual — Connecting
Page 2 · click to enlarge
Page 2

LED Description Package Contents

Interface Description

Fortinet 2002F — LED Description Package Contents diagram (page 2)
Fig. 4 · LED Description Package Contents
LEDStateDescription PowerGreenThe unit is powered on. OffThe unit is powered off. NormalGreenThe unit is being used in Normal mode. HAGreenThe unit is being used in a HA cluster. OffThe unit is in stand-alone mode. BypassGreenBypass network activity at this inter face. OffNormal status. INT and EXT LEDsGreenThe correct cable is in use and the connected equipment has power. Green flashingNetwork data is being sent or re ceived. OffNo link established or the interface has been turned off. MGMT1 and MGMT2 PortsLink/Activity (left) GreenPort has power and network connec Link/Activity (left) Green flashingtion. Network data is being sent or re ceived. Speed (right) indicator is GreenConnected at 1000 Mbps. Speed (right) indicator is AmberThe interface is connected at 100 Mbps. Speed (right) indicator is OffThe interface is connected at 10 Mbps.
InterfaceTypeSpeedProto colDescription Console1 and Con sole2RJ-459600 bps 8/N/1RS-232 serialConnection to the manage ment computer. Provides access to the command line interface (CLI). Modem1 and Mo dem2RJ-11Phone line for internal modem. USB1 and USB2USBUSBTwo optional connections to a USB key for installation. MGMT1 and MGMT2RJ-4510/100/1000 Base-TEthernetTwo management ports. INT1, INT3, EXT1, and EXT3LC SFP1000Base-SXEthernetFiber optic connections to gigabit optical networks. INT2, INT4, EXT2, and EXT4SFP1GB-SXEthernetSmall form-factor pluggable transceiver.
Fortinet 2002F — LED Description Package Contents diagram (page 2)
Fig. 5 · LED Description Package Contents

Copyright 2010 Fortinet Incorporated. All rights reserved. Trademarks Products mentioned in this document are trademarks.

Connecting

Connect the FortiBridge unit to the internal and external networks and the Forti Gate unit. Normally, you would use straight-through ethernet cables to connect the FortiBridge unit. However, for some connections you may need a crossover ethernet cable (for example, for compatibility with network devices that do not support Auto MDI/MDIX).

Administrator user nameadmin Administrator password(none) NAT/Route mode Management1192.168.1.99 Management20.0.0.0
  • Connect the FortiBridge INT 2 interface to the FortiGate unit internal inter face.
  • Connect the FortiBridge EXT 2 interface to the FortiGate unit external inter face.

To reset the unit to the factory defaults, in the CLI type the command: execute factory reset

  • Connect the FortiBridge INT 1 interface to the internal network.
  • Connect the FortiBridge EXT 1 interface to the external network.
  • Turn on the FortiGate unit and any network equipment that was turned off.
  • Connect the power cords at the back of the FortiBridge unit. Plug the other end of the power cables into a grounded electrical outlet.
  • The PWR and Bypass Mode LEDs turn on. After a short time, the Forti Bridge unit switches to Normal mode. The Bypass LED turns off and the Normal LED turns on.
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Fortinet 2002F

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fortinet 2002F

Be the first to ask — other owners or our team will answer.

Original document

Fortinet 2002F manual PDF

2 pages·573 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…