EN
Fishman logo
Official user manual

Fishman LDS9000

32 pages·809 KB·Water Dispenser·PDF·ENDEFRITNLJA
Fishman LDS9000
Table of Contents 31 sections Introduction · Table of Contents · Getting Started · Specifications · … ShowHide
Page 1 of the Fishman LDS9000 user manual — Operating Guide LDS 9000
Page 1 · click to enlarge
Page 1

Operating Guide LDS 9000

AirFree

AirPulse

™ CA Dispenser

™ Dispenser

Fishman LDS9000 — Operating Guide LDS 9000 diagram (page 1)
Fig. 1 · Operating Guide LDS 9000
Page 2 of the Fishman LDS9000 user manual — Introduction
Page 2 · click to enlarge
Page 2

Introduction

Thank You for purchasing the Fishman LDS9000

AirFreeTM dispenser. Our 9000-line of AirFree dispensers uses a patented

positive displacement technology to provide the highest level of repeatability

of any dispenser utilizing a syringe as a reservoir. We guarantee it.

Please spend a few moments familiarizing yourself with the LDS9000

dispenser. Our recommended testing procedures provide an interactive

tutorial on the dispenser’s functions.When complete, review the helpful

information we have included based on our 40 years of dispensing experience.

After completing the guide, should you have any additional questions please

don’t hesitate to contact Fishman or your authorized Fishman dealer.

US & Canada800-433-2115
United Kingdom1285 644211
Worldwide1-508-435-2115
Fishman LDS9000 — Introduction diagram (page 2)
Fig. 2 · Introduction

T h e F i s h m a n P r o m i s e

We promise that our products will operate to your complete satisfaction. We strive for the highest standards regarding quality, workmanship and attention to detail.

If for any reason you feel that you are not satisfied with our products or support, I extend the offer to write or call me personally. Our interest is to build partnerships through understanding your needs and incorporating them into our products and services.Your trust in Fishman is our ultimate reward.

Page 4 of the Fishman LDS9000 user manual — Getting Started
Page 4 · click to enlarge
Page 4

Getting Started

This manual contains all the information you will need to set up and test the 9000 series AirPulseTM dispensers.

  • You will find the hook up for the LDAV on pages 10-15. For the MDAV, review 16-19. For the SDAV review 20-23.
  • Next, pages 24-25 will show your how to set up and test a thick paste-like material.
  • Finally, pages 26-27 explain how to dispense watery fluids using vacuum control.

The remainder of the manual applies to all 9000 series AirFreeTM

dispensers.

Unpack the shipping box and use the supplied checklist to assure all

items are present. If an item is missing, please contact us immediately.

Make sure the set up area has access to power. No compressed air will

be needed. You are about to experience the world’s only AirFreeTM fluid dispenser. No compressors, no filtration, no plumbing.

Activate your extended two (2) year no-fault warranty by following the

instructions in the enclosed “On Line Warranty” letter to activate online. Once your dispenser is set up, return to this section to familiarize yourself with the multiple functions of the program controls.

First Steps

Page 5 of the Fishman LDS9000 user manual — Specifications
Page 5 · click to enlarge
Page 5
Fishman LDS9000 — Specifications diagram (page 5)
Fig. 3 · Specifications
Size7.63 x 8.75 x 3.5in (19.4 x 22.2 x 8.9cm)
Page 6 of the Fishman LDS9000 user manual — Operation
Page 6 · click to enlarge
Page 6

Operation

The LDS9000 Dispensing System uses a patented Linear Drive System (LDS) to transfer force from the drive motor to the syringe piston. The motor, lead screw and syringe piston are linked mechanically. Each attachment (gun to reservoir, gun to piston, piston to reservoir) is specifically designed to provide zero flexing in the system during a dispense. Simply put, zero flexing is what makes the LDS9000 the world’s most repeatable dispenser.

Fishman LDS9000 — Operation diagram (page 6)
Fig. 4 · Operation

Once the dispense cycle is complete, a programmed mechanical pullback retracts the drive rod which is mechanically attached to the AirFreeTM piston. The combined action of the plunger with the preprogrammed forward steps, and pullback feature produces a highly repeatable deposit with no post-dispense ooze. A pause between forward and reverse motion can be programmed in for use with compressible fluids.

The inner diameter and length of the syringe barrel are used to calculate dispense volume. For example, the inner diameter of a 10cc syringe barrel measures 1.63cm. One forward step of the motor moves the drive rod/piston .00127cm, resulting in .0026cc of fluid being displaced. With a 5cc barrel, it takes two steps to displace the same amount of fluid.

An electronic signal is sent via the electronic control cable that connects the dispense gun to the control box. The signal energizes the motor pushing the drive rod, attached to the piston, into the syringe barrel. The forward motion forces the fluid out to make a deposit.

The LDS9000 features a universal power supply. It automatically adjusts for input voltages ranging from 100 VAC to 240 VAC. There is no adjustment required by the user.

Flexible Control Cable · Power Supply

Page 7 of the Fishman LDS9000 user manual — Program Control
Page 7 · click to enlarge
Page 7
Fishman LDS9000 — Program Control diagram (page 7)
Fig. 5 · Program Control
  • Each mode provides you access to different features on the liquid crystal display. Use the Auto/Manual switch to move back and forth from manual mode to automatic mode.
  • In manual mode, you can use the foot pedal to dispense a deposit or bead “by eye”. You are in manual mode when the Auto/Manual toggle switch is in the downward position.
  • In Automatic Dispense mode, you can set several variables, including program number, syringe barrel size, deposit volume, dispense rate, pullback, delay. You are in automatic dispense mode when the Auto/Manual toggle switch is in the upward position.

In manual mode, flip the Extend switch, located on the control panel, from Extend to Retract to engage the motor in reverse direction. This will draw fluid back into the reservoir stopping any ooze.

In both manual and auto mode, flip the Foot/Hand switch, from Foot to Hand to operate the dispenser with a finger switch. Finger switches are sold separately.

Manual/Auto Dispense · Reverse Motion—Drawback · Hand Control

Page 8 of the Fishman LDS9000 user manual — P SYRINGE:30CC
Page 8 · click to enlarge
Page 8

How to use the Control Pad

Fishman LDS9000 — How to use the Control Pad diagram (page 8)
Fig. 6 · How to use the Control Pad

P SYRINGE:30CC

1 VOLUME: 4.99

Wait 3-5 seconds for on-screen instructions

When in program mode, if you are not sure what to do wait approximately 3-5 seconds and rolling instructions appear. If you missed them, not to worry, they will repeat until you make an entry.

New or Saved Program

In Auto Mode hit the NEXT key. Hit the left arrow to enter a new program or hit the right arrow to enter a saved program.

Edit the existing program

In Auto mode hit the BACK key once to enter the program manager. Each time you hit the BACK key it shows a different program parameter. Find the one you wish to edit, make your edit and hit the ENTER key. Hit the NEXT key as many times as needed to return to program mode. Follow on-screen instructions.

In Auto mode when entering a new program or editing an existing one, when prompted for a dispense volume press the digit keys to type the amount you require. Press the ENTER key to save your input.

Skip forward/back through the menu

In Auto mode, press the NEXT key to skip one slot forward in the programming menu. Use the BACK key to skip back one slot in the programming menu.

On Screen Instructions · Enter a Volume

Page 9 of the Fishman LDS9000 user manual — How to U se the Control Pad
Page 9 · click to enlarge
Page 9

How to U se the Control Pad

Erase an Input or Make a Selection

In Auto mode when entering a new program or editing, use the left and right arrow keys to erase and input or skip between choices such as multiple saved programs. Use the ENTER key to select a choice.

In auto or manual, always use the ENTER key to save an input or selection. The NEXT or BACK keys do not save—they only skip to the next choice. The ENTER key saves your data.

Jog Between Menu Choices

In auto or manual, always use the left or right arrow to move between menu selections.

Fishman LDS9000 — How to U se the Control Pad diagram (page 9)
Fig. 7 · How to U se the Control Pad
Show 4 more labels / short text on this page
Confirming a Choice · Back Panel · Foot Pedal · Power Cord Receptacle
Page 10 of the Fishman LDS9000 user manual — LDS9000 Gun Assembly
Page 10 · click to enlarge
Page 10

LDS9000 Gun Assembly

Fishman LDS9000 — LDS9000 Gun Assembly diagram (page 10)
Fig. 8 · LDS9000 Gun Assembly

SureLok™ Retaining Ring Cover

Show 6 more labels / short text on this page
Barrel Reservoir · PosiLokTM Piston · Piston Hub · Lead Screw · Dispensing Gun · LDS9000 Gun
Page 11 of the Fishman LDS9000 user manual — Attaching the Syringe
Page 11 · click to enlarge
Page 11
Fishman LDS9000 — Attaching the Syringe diagram (page 11)
Fig. 9 · Attaching the Syringe
  • Make sure a tip cap is on the barrel.

Holding the dispensing gun with the piston hub pointed upward, place the barrel over the piston hub of the dispense gun.

Holding both loosely. Step on the foot pedal until the barrel ears are raised at least 1/4” (.635mm) above the plate.

Page 12 of the Fishman LDS9000 user manual — Attach the Syringe (continued)
Page 12 · click to enlarge
Page 12

Attach the Syringe (continued)

Attaching the Syringe (continued)

Fishman LDS9000 — Attach the Syringe (continued) diagram (page 12)
Fig. 10 · Attach the Syringe (continued)

Manually twist the barrel in a clockwise direction until the luer lock connector is finger tight and the ears of the barrel are flush against the retaining plate. It may be necessary to set the EXTEND/RETRACT switch to RETRACT and step on the foot pedal to bring the barrel ears completely flush to the retaining plate. If you set the switch to RETRACT be sure to set it back to EXTEND before proceeding.

Slide the retaining ring cover over the syringe and rotate the cover in a clockwise direction.

The syringe should be firmly connected to the dispensing gun.

Page 13 of the Fishman LDS9000 user manual — Removing the Syringe
Page 13 · click to enlarge
Page 13
Fishman LDS9000 — Removing the Syringe diagram (page 13)
Fig. 11 · Removing the Syringe

control unit will display a message: “Remove syringe and press enter.”

Twist the barrel reservoir clockwise to remove it from the piston hub.

Page 14 of the Fishman LDS9000 user manual — <- SHOT SIZE ->
Page 14 · click to enlarge
Page 14

Program Function

The LDS9000 AirFreeTM Dispensing system allows 10 user-defined programs to be stored in memory, ranging from 0 to 9. The program stores:

  • Barrel reservoir size
  • Deposit volume
  • Dispense rate
  • Backoff or Pullback
  • Delay between forward and reverse motion

<-SYRINGE SIZE->

Follow These Steps to Input a Program

3 5 10 30

  • Press the NEXT key

Use the left and right arrow keys to select your syringe size.

.01 cc .00261-12.2335

Enter your dispense volume by using the keypad to enter your volume followed by pressing the ENTER key or use the left or right arrows to use the SpeedBarTM feature*.

.392 cc/sec .065 - 1.567

Enter your dispense rate by using the keypad to enter the volume followed by pressing the ENTER key or use the left or right arrows to use the SpeedBarTM feature*.

5 STEPS 0 - 500

Enter the amount of back off by using the keypad followed by pressing the ENTER key or use the left or right arrows to use the SpeedBarTM feature*.

Enter the amount of delay (0-9 seconds) between forward and reverse motion by using the keypad followed by the ENTER key.

0 seconds .00 - 10.00

*SpeedbarTM—This feature is available in the volume input, dispense rate input and backoff input. Hold down the left or right arrow key to make this feature appear. Continue holding to make the bar increase or decrease. The longer you hold, the faster the bar moves. When satisfied, release the key and SpeedbarTM will show you your selected volume.

<- SHOT SIZE ->

0cc 12cc

Page 15 of the Fishman LDS9000 user manual — DEFAULT POWER-ON
Page 15 · click to enlarge
Page 15

Program Function

To save program, answer YES followed

SAVE PROGRAM?

by the program number (0-9) of the location you wish to save your program.

<- YES NO ->

If you want the program to automatically load as the default program when the machine is turned on, answer YES to the default question.

DEFAULT POWER-ON

<- YES NO ->

  • Press the foot pedal to dispense the first deposit

Follow These Steps to Edit a Program

  • Press the BACK key to enter the program manager.

the start of the program manager. The NEXT key moves you through each parameter to the bottom of the program manager.

  • Press the BACK key as many times as you need to get to the parameter you wish to edit.
  • Use the keypad to make your edit followed by the enter key.
  • Use the NEXT/BACK keys to make any remaining edits.
  • When finished, use the NEXT key as many times as needed to get to the Save menu.
  • Save your program edits.
Page 16 of the Fishman LDS9000 user manual — PROGRAM MANAGER <-NEW SAVED->
Page 16 · click to enlarge
Page 16

Program Function

Follow these steps to save a program to a different location.

  • Press the BACK key to enter the program manager.
  • Press the NEXT key to enter the Save menu.
  • Press the left arrow to make the save.
Fishman LDS9000 — Program Function diagram (page 16)
Fig. 12 · Program Function
  • Select a location by pressing a digit from 0-9.

program you will be asked if you wish or overwrite the program.

  • Decide if you want your saved program to default at start up by choosing yes or no.

Follow these steps to restore a program at Start Up.

  • Press the right arrow to enter the Save menu.

PROGRAM MANAGER <-NEW SAVED->

  • If you know the number of the program you wish to restore, press the number now on the keypad to restore the program.
  • If you do not know the program number hit the right arrow to review the saved programs.

worry if you miss a program, the scroll feature will repeat until you make a selection

  • When you see the program you want appear on the screen press the NEXT key and the program will restore.

Follow these steps to restore a program while in an active program.

  • Press the NEXT key.
  • If you know the number of the program you wish to restore, press the number now on the keypad to restore the program.
  • If you do not know the program number hit the right arrow to review the saved programs.
  • When you see the program you want appear on the screen press the NEXT key and the program will restore.
Page 17 of the Fishman LDS9000 user manual — How to Make a Bead
Page 17 · click to enlarge
Page 17

How to Make a Bead

Fishman LDS9000 — How to Make a Bead diagram (page 17)
Fig. 13 · How to Make a Bead

To dispense a continuous bead of fluid instead of a single dot, follow these steps.

Switch the AUTO/MANUAL switch to

MANUAL.

Fishman LDS9000 — How to Make a Bead diagram (page 17)
Fig. 14 · How to Make a Bead

Set the shot size to the lowest setting.

For best results, set the dispense rate to slow, to minimize backpressure in the syringe.

As a beginning point, set drawback to 5 steps

Keep delay set to zero, then adjust as needed to eliminate any post dispense ooze.

  • Press and hold the foot pedal until the required amount is dispensed.
Page 18 of the Fishman LDS9000 user manual — Operating Tips
Page 18 · click to enlarge
Page 18
Fishman LDS9000 — Operating Tips diagram (page 18)
Fig. 15 · Operating Tips
  • The faster you dispense the more backoff you will need. That’s because the speed at which the piston is traveling exceeds the flow rate of the material out of the dispense tip. Therefore, creating internal pressure. More reverse motion is required to get the internal reservoir pressure back to zero. We recommend you start with a slow rate and progress from there.
  • The LDS9000 positively displaces fluids. That means if you program .02cc’s of fluid, you will get .02cc’s out of a very small tip or a large tip. The only difference is trying to force the fluid through a very small tip will take twice as long. We recommend you increase the fluid flow by using our FreeFlow TM tapered tip.
  • A change in the dispense rate will change your deposit size. When the piston moves forward it often exceeds the flow rate of the fluid, thus creating pressure buildup. The best way to rapidly relieve that pressure is to apply reverse motion. When the dispense rate is doubled the fluid has half the time to flow before reverse motion, therefore the deposit size becomes smaller. Conversely, when the dispense rate is cut in half the fluid has twice the time to flow before reverse motion, therefore the deposit size becomes larger. The only way to maintain the same deposit size at all speeds is to adjust all parameters.

First Shot Set Up

  • Follow the steps listed in the LDS9000 Rapid Setup Guide. We recommend you work with the Fishman test fluid provided in your dispenser to establish the first deposit.
  • When priming your dispense tip watch how long the fluid flows out of the tip. Little to no ooze, start with a minimum amount of backoff (1-10 steps). Lots of ooze, start with a higher amount of backoff (10-25 steps) and adjust from there.
  • Start with a slow dispense rate and adjust your dispense volume and backoff until you achieve the right size deposit. Once your deposit is stabilized try adjusting the speed to your liking, watch the effect on your deposit. Return to volume and backoff to tweak the deposit size. Always allow the deposit to stabilize via 5 or 6 dispenses before making the next adjustment.

Suggested Tips

Page 19 of the Fishman LDS9000 user manual — Operating Tips
Page 19 · click to enlarge
Page 19
Fishman LDS9000 — Operating Tips diagram (page 19)
Fig. 16 · Operating Tips
  • Always use Fishman AirFree™ barrel reservoirs and dispense tips. Safely dispose after use. This method prevents contamination, ensures proper safety and provides maximum cleanliness.
  • The heart of the Linear Drive System (LDS) is the AirFree™ piston. The specially designed luer connection provides a no slip connection assuring the highest deposit repeatability.
  • Use Fishman FreeFlow™ tapered dispense tips. Small gauge tips will only create backpressure, put stress on the fluid and cause ooze. The Linear Drive System will positively displace fluids, which allows the use of larger tips with no effect on performance. The FreeFlow™ taper tips eliminate fluid flow restrictions preventing drooling and ooze.
Fishman LDS9000 — Operating Tips diagram (page 19)
Fig. 17 · Operating Tips
Page 20 of the Fishman LDS9000 user manual — Loading the Reservoirs
Page 20 · click to enlarge
Page 20

Loading the Reservoirs

Avoid Air in the Syringe Barrel

Trapped air in the fluid creates voids that will make the fluid compressible. Although the LDS9000 Linear Drive System is stable enough to handle most compressible fluids excess air will force the user to use a greater amount of pullback. This will create a greater amount of forward and reverse motion in the syringe during a dispense cycle. Excess motion will put more stress on the fluid being dispensed. The goal is to reduce dispense motion as much as possible to protect the fluid and maximize repeatability. Paying attention to minimization during syringe filling will drastically improve performance.

For best results, use a Fishman barrel filing station (see next page). If needed, use a centrifuge or vacuum chamber to eliminate any trapped air.

Fishman LDS9000 — Loading the Reservoirs diagram (page 20)
Fig. 18 · Loading the Reservoirs

Twist on a tip cap and pour your fluid into the barrel using a funnel. Insert a Venting Ribbon along the inside edge of the barrel, followed by an AirFree™ piston. Carefully press down until it contacts the fluid. While holding the piston in place gently pull the Venting Ribbon from the barrel.

Thick or Non Leveling Fluid

If the fluid comes packed in a caulking cartridge try loading the reservoir with a caulking gun. If not, spoon-feeding with a spatula often works. Follow the loading by inserting the Venting Ribbon along the inside of the barrel, followed by AirFree™ piston. Carefully press down to move the fluid to the bottom of the barrel and to remove trapped air. While holding the piston in place gently pull the Venting Ribbon from the barrel.

Pourable Fluid

Page 21 of the Fishman LDS9000 user manual — Alternative Filling Methods
Page 21 · click to enlarge
Page 21

Alternative Filling Methods

  • If your fluid comes prepackaged in a medical style syringe use the Fishman B250001 luer-to luer fitting to transfer the material from prepackaged syringe to the Fishman syringe.
  • Another option is to use the Fishman C370001 AirPulse TM reservoir filler. Purchase your fluid in a 12oz cartridge or prepack the cartridge yourself. The prepackaged cartridge easily sips into the barrel loader. Air pressure, activated by a finger switch, transfers the fluid from the cartridge to the Fishman syringe (piston inserted), filing from the bottom up.
  • If the fluid comes prepackaged in a 1/10 gallon caulking style cartridge use the Fishman B250001 barrel loader. Operation is exactly as above; the only difference is the reservoir is designed to fit the caulking cartridge.

For additional assistance, contact one of our Application Specialists:

Fishman LDS9000 — Alternative Filling Methods diagram (page 21)
Fig. 19 · Alternative Filling Methods
Page 22 of the Fishman LDS9000 user manual — Dispense Rate:
Page 22 · click to enlarge
Page 22

Defining the System

Program mode is ideally suited for dot type applications or automated (XYZ system) beads. This mode allows you to program a desired volume of fluid for repeated and consistent output. In the program mode there are two utilities. Program Manager and the Save/Restore Manager.

Utility 1Program Manager

The Program Manager has five adjustable parameters:

  • Barrel Selection
  • Dispense Volume
  • Dispense Rate
  • Drawback
  • Drawback Delay

Barrel Selection:

The selection of the proper barrel is critical to positive displacement dispensing. For the best results always select the smallest barrel reservoir that will work for your application. To minimize set up time we preprogrammed the control unit using standard Fishman luer lock barrels. Simply select the proper size (3,5,10,30) and move to the next parameter.

Dispense Volume:

Having the ability to enter a dispense volume is what separates the LDS9000 from traditional pneumatic dispensing systems. Our patented technology allows us to apply a formula based on the syringe’s inner diameter and the distance traveled by the PosiLokTM

piston to arrive at the desired volume. This method drastically reduces the amount of time consumed by the guesswork of the pneumatic systems.

Dispense Rate:

This is an important parameter that allows the LDS9000 to dispense a wide range of material. By altering the speed at which the Linear Drive System travels down the barrel, we can dispense non-compressible to thixotropic materials with little to no impact on rheology. The microprocessor calculates dispense rate in the cc per second.

Program Mode

Page 23 of the Fishman LDS9000 user manual — Drawback Delay:
Page 23 · click to enlarge
Page 23

Defining the System

Drawback:

Upon completion of the dispense cycle, fluid oozing out of the dispense tip is a common problem when dispensing compressible fluids. The Drawback parameter eliminates any oozing by implementing a mechanically reversed action at the end of the dispense cycle. Because the system is intelligent, it knows the distance traveled forward and the distance traveled back. Therefore, on the next dispense cycle, the system will add the distance traveled back to the forward motion, guaranteeing a positive displaced dispense every time.

Fishman LDS9000 — Defining the System diagram (page 23)
Fig. 20 · Defining the System

Example: The system converts dispense volume to motor steps. Assume .02cc equals 20 steps. The following is what happens when 10 steps of reverse motion is added.

Drawback Delay:

This parameter is most useful when potting or beading with a compressible fluid. A delay (in seconds) is applied between the end of the forward motion and the start of the reverse motion when drawback steps are programmed. This allows the entire programmed shot to dispense prior to the reverse motion.

Utility 2Save/Restore Manager

The Save/Restore Manager has three adjustable parameters:

  • Save your program to ten locations
  • Recall your program from ten locations
  • Set a program as the default on start up.

The Save/Restore Manager allows you to save and recall up to ten different programs, eliminating setup time when changing dispense volumes. Also, you may specify one program as the default program meaning this program will automatically load when the controller is turned on. This is useful when multiple LDS9000 are used on a production line. You are assured all systems will start with the same program.

Page 24 of the Fishman LDS9000 user manual — The Dispense Gun— The precision of AirFree dispensing technology
Page 24 · click to enlarge
Page 24

Defining the System

Program is ideally suited for priming the dispense tip and manual dispensing such as potting and beads. In manual mode the parameters and function of the parameters are exactly the same as program mode. The only difference is that the system will only dispense fluid for the amount of time the user holds the foot pedal down.

The Linear Drive System

AirFree PosiLok TM Piston— The heart of AirFree dispensing

This unique design has made positive displacement with a barrel reservoir possible. Re-engineering the pneumatic piston concept, the high interference fit of the piston and the luer lock connection with the Linear Drive System enables intelligent dispensing. By increasing the interference between the O.D. of the piston and the I.D. of the barrel, we are able to completely seal the chamber eliminating material leakage. The luer lock connection provides complete control over forward and reverse motion. The intelligent control unit microprocessor knows the barrel I.D., the distance traveled forward and the distance traveled backward. With every dispense cycle the piston moves the exact distance every time, guaranteed. Drip-free dispensing, air pocket venting and all-plastic component dispensing are maintained with the new design.

The Dispense Gun— The precision of AirFree dispensing technology

The motor used inside the dispense gun is a linear actuator. The linear actuator creates forward motion by rotating nut between electrically charged poles. The drive screw runs through the nut located at the center of the motor. The design of the plastic gun housing captures the top of the drive screw preventing it from rotation. When electrically charged, the center nut will step from one magnetic pole to the other, moving the drive screw forward. It is important to note that the drive screw not rotating allows the attachment of the PosiLokTM piston, creating the linear motion critical to positive displacement. By reversing the charge, we are able to create reverse motion.

Manual Mode

Page 25 of the Fishman LDS9000 user manual — The Control Unit— The brains of AirFree dispensing
Page 25 · click to enlarge
Page 25

Defining the System

Retaining Ring— The brawn of the AirFree dispensing technology

The multi-legged stainless steel design locks the syringe in place, making the syringe and gun one. In dispensing, any flexing between the barrel reservoir and surface to which it is secured represents a pressure loss and will change the amount of fluid dispensed. Due to the tight tolerance between the stainless steel retaining ring and the gun, there is no room for barrel flexing when the thrust-of-dispense cycle is applied. This is a key contributor to maintaining positive displacement dispensing.

The Control Unit— The brains of AirFree dispensing

The control unit gives the user control over volume output; dispense rate, reverse motion and motion delay. By imputing and manipulating these parameters, the microprocessor will calculate the number of steps needed to achieve the requested result. A universal switching power supply automatically adapts to multiple AC inputs. The foot pedal may be removed for automated activation using a dry contact.

Helpful Hints Priming the System

Removal of the tip cap and introduction of a new needle traps air pockets inside the stem of the syringe and hub of the needle. Because our system positively displaces fluid, it is very important no air is present in any portion of the syringe. Therefore, it is important that any trapped air is pushed out of the syringe prior to dispensing.

Same Size Barrels: Simply switch one barrel for the next. The only consideration is to prime the new dispense tip prior to dispensing (page ?). The LDS9000 recognizes barrels of the same size so it is not necessary to reset the system.

Different Size Barrels: When changing to a different size barrel, it is necessary to reset the lead screw, reset the dispense parameters and prime the dispense tip. To reset the lead screw remove the barrel reservoir, flip the Auto/Manual switch to Manual and the Extend/Retract switch to Retract. Hold the foot pedal down until the lead screw retracts all the way into the dispense gun.

Changing Barrels Reservoirs

Page 26 of the Fishman LDS9000 user manual — How the LDS9000 Works
Page 26 · click to enlarge
Page 26

How the LDS9000 Works

With the power ON, here’s what happens when you press the foot pedal:

The program is engaged, the motor is energized beginning the dispense

cycle countdown.

The motor pushes the lead screw, with piston attached to the end,

down the barrel pushing the liquid out the dispensing tip.

At the end of the program, the motor is de-energized—stopping

forward movement of the lead screw and stopping all fluid flow.

If drawback is programmed, the motor is re-energized and begins a drawback cycle countdown.

The motor retracts the lead screw, with piston attached to the end,

creating a vacuum that stops any post dispense oozing. The vacuum is controlled by the software program.

When in manual mode the microprocessor switches to direct motor control by the foot pedal. As long as the foot pedal is pressed, the motor remains energized, providing a flow of liquid for filling or beading.

Page 27 of the Fishman LDS9000 user manual — Troubleshooting
Page 27 · click to enlarge
Page 27

Troubleshooting

Problem: The fluid continues to ooze long after the dispense, (including drawback) is completed.

Potential Solutions:

  • Check the needle size. The unpredictable nature of the pneumatic drive system has forced customers to use the needle as a flow control. What this means is that they use an ultra small (25G) needle to control the flow fluid because the pneumatic drive system can’t.
  • Check that the syringe is packaged air free. The presence of air will cause oozing. It is recommended the syringes be packaged using centrifuge or vacuum when possible.
  • Make sure you are using an PosiLok TM piston. Pistons are included in your dispense kit.

Problem: The fluid is blowing by the AirFreeTM piston.

Potential Solutions:

  • Examine the seal of the piston. Sometimes syringe fillers, either by rushing or attempting to squeeze air out, allow fluid to permeate the front seal of the piston. When the front seal is maintained the piston will not leak. Also, adding a Fishman Piston Stabilizer will help. See Accessories for ordering information.
  • Make sure you are using Fishman Syringes. The inner diameter has been preloaded into the software for dispense calculations. Competitor’s syringes have different diameters, which will cause problems trying to achieve the dispensed amount.
Page 28 of the Fishman LDS9000 user manual — MANAGER
Page 28 · click to enlarge
Page 28

Glossary

FOOT Setting for using a foot pedal to activate dispensing cycle

HAND Setting for using finger switch to activate a dispense cycle

SYR Syringe— barrel reservoir selection

DIA Length—user-defined syringe inside length from ears to bottom in

V Volume—Volume to be dispensed, in cubic centimeters

R Dispense Rate—The rate, in cubic centimeters per second, at

which you want to dispense the fluid

PRGM Program key to enter or exit at AUTO DISPENSE PROGRAM

MANAGER

ENTER Key to activate desired parameter

NEXT Key to advance to the next screen without changing the exiting

SYRINGE ATTACHMENT The ideal position for the ears of the barrel reservoir after locking

it into place, is flush up against the retaining plate. Note: Always attach a new barrel reservoir with the tip cap on.

PRIMING THE SYSTEM Eliminates any trapped air between the barrel reservoir and

needle. Always prime the system at start up.

PARAMETER LIMITS If you want to know the min., max, or high and low values of

parameters for a given syringe, type in 999 at the prompt and press the ENTER key. View the display; it will flash the values on the screen and then return.

RETRACT When you are in program mode and you change the

EXTEND/RETRACT switch to RETRACT, the system will prompt you to hit the ENTER key or flip the switch back to EXTEND. This is a safety precaution. If you retract with the PosiLok

TM piston attached, the barrel reservoir will fill up with air from the open end. Before you use the retract feature, be sure you remove your barrel reservoir. When retracting the lead screw in manual mode, all you have to do is flip the EXTEND/RETRACT switch to RETRACT. The PosiLokTM

piston will retract for as long as the foot pedal is depressed.

millimeters · parameters

Page 29 of the Fishman LDS9000 user manual — Glossary
Page 29 · click to enlarge
Page 29

Glossary

DISPENSE RATE Always start with the slowest recommended rate and increase

incrementally.

DRAWBACK DELAY When using a small needle you can take advantage of the

drawback delay feature to give you more control over your output volume. This feature allows the fluid to flow out of the syringe before you drawback the PosiLokTM piston and begin your next dispense cycle.

FACTORY SETTINGS The factory settings will be replaced with your settings when you

save into location #1 and #2

SAVE When you save an application into a location that has a

previously stored application, you will be asked to replace the existing application.

RESTORE When you restore an application from a location, the parameters

will flash on the display. You will then be asked to restore the application.

ACTIVATING A PARAMETER if you notice that a parameter that you set didn’t take effect,

make sure you pressed the ENTER key before proceeding to the next screen. If you did not press the ENTER key, the values you entered will not take effect on the next dispensing cycle.

NEEDLE SELECTION When selecting a needle we recommend using the FreeFlowTM tip

with the LDS9000. This tip allows the least amount of flow restriction thus allowing positive flow of the fluid from the syringe.

PREPACKAGED SYRINGE Must be free of air pockets to receive the full benefits of the

LDS9000. Contact your Fishman representative for AirFreeTM

filling suggestions.

Page 30 of the Fishman LDS9000 user manual — PosiLok TM Teflon ® - Lined Dispense Tips
Page 30 · click to enlarge
Page 30

Dispenser Component Selector Guide

The charts below are only a small sample of available Fishman components. Please refer to the complete Fishman catalog to view the entire product line.

Retaining Ring

PosiLok TM Flexible Dispense Tips

The unique multi-legged design firmly locks the barrel into place eliminating any possibility of pressure loss during dispense.

Soft polypropylene burr and flash free tips assure accurate deposit control.

Gauge ID .5” 1.5” Color 15G .049” Z532115 Z534115 Brown 18G .032” Z532118 Z534118 Dk. Green 20G .019” Z532120 Z534120 Pink 25G .014” Z532125 Z534125 Red

Size Retaining Ring Quantity Per Pack 3cc O312291 1 10cc O314291 1

Fishman LDS9000 — Retaining Ring diagram (page 30)
Fig. 21 · Retaining Ring

AirFree TM CA Barrels/Pistons

Accessories

Each package contains same amount of barrels and PosiLok™engageable pistons.

Gun Stand Holds the dispense gun when not in use.

Size Clear Quantity Per Pack 3cc O502051 50 10cc O504171 30

Piston Stabilizer Attaches to the end of the Linear Drive System dispense rod. Clam shell design clamps onto the piston hub. Each kit contains a piston stabilizer, assembly tool and instructions

PosiLok TM Teflon ® - Lined Dispense Tips

5cc Stabilizer Kit Y010101 10cc Stabilizer Kit Y020101 30cc Stabilizer Kit Y030101

ID 1/2” Length Hub Color

.020” Z592121 Gray .006” Z592125 Pink

Automation Gun Bracket Mounts the gun to an XYZ dispense station.

LDS9000 Stand D600001 · LDS9000 Bracket Y200001

Page 31 of the Fishman LDS9000 user manual — F
Page 31 · click to enlarge
Page 31
Fishman LDS9000 — Warranty diagram (page 31)
Fig. 22 · Warranty
Fishman LDS9000 — Warranty diagram (page 31)
Fig. 23 · Warranty

Two Year Fault-Free Warranty

Fishman Corporation (Fishman) warrants its product to be free from defects in materials and workmanship for a period of two years from the date of purchase.

Under this warranty, Fishman will repair or replace any defective part or, at its own option, the complete dispenser regardless of fault.To obtain service under warranty, product must be returned, freight prepaid, to Fishman.

Before use, the customer must determine the suitability of the product for their intended use and therefore customer assumes all risk and liability connected with products use.

At no time under any circumstance shall any liability or obligation of Fishman arising from the warranty exceed the purchase price of the product.

Except as provided herein, Fishman makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. In no event will Fishman be liable for direct, indirect, special, incidental, or consequential damages arising out of use of this product.

F

O

R

N

D

U

S

T

E

D

R

A

O

N

M

A

D

E

N

S

U

S

A

M

S

A

M

N

M

U

F

O

A

T

A

S

R

U

U

N

N

E

D

A

M

G

Page 32 of the Fishman LDS9000 user manual — Contact Info
Page 32 · click to enlarge
Page 32

192 South Street Hopkinton, MA 01748 800-433-2115 Fax 508-435-2119 www.fishmancorp.com email: fishman@fishmancorp.com

Fishman Corporation

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Fishman LDS9000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fishman LDS9000

Be the first to ask — other owners or our team will answer.

Original document

Fishman LDS9000 manual PDF

32 pages·809 KB·Water Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…