Instruction/ maintenance manual of the product DD605 Fisher & Paykel
Go to page of 28
DishDra wer Installation instructions NZ A U GB IE DD605 and DS605 models.
Safety and warnings Impor tant safety precautions! Installation of this DishDrawer® requires basic mechanic al and electrical skills. Be sure to leave these Instructions with the Customer . Installation must comply with your loc al building and electricity regulations.
1 Contents DOUBLE MODELS Product and cabinetry dimensions 2 Installation Cavity prepar ation 4 Route the hoses and mov e into the cavity 5 Removing the tub and levelling the pr oduct 6 Securing the pr.
2 Pr oduc t dimensions O B C E D F G H J N P Pr oduct dimensions (mm) Pre nished L CD DD605 Pre nished Flat door DD605 Integrated DD605 A overall height* of product 819.5 - 879.5 819.5 - 879.5 819.5 - 879.5 B overall width of product 595 595 595 C overall depth of product (excl.
3 Cabinetry dimensions A B C D Cabinetry dimensions (mm) Pre nished LC D DD605 Pre nished Flat door DD605 Integrated DD605 A inside height of cavity 820 - 882.
4 Note: Services can be located either side of DishDr awer®. Ca vity preparation Parts supplied These marks indicate mounting tab screw locations Pref erred position. If adequate clearance, services hole can be higher to clear toe kick space. If hole is higher , ensure drain hose(s) are r outed straight into the waste connection.
5 Route the hoses and mov e into the ca vity DOUBLE MODELS 2 1 1 1 2 3 3 optional 1 b 2 optional 1 a Tie together to a void kink ing If top two tabs are being used, ensure they’r e securely fitted before sliding pr oduct into cavity . Ensure hoses and cord are not kinked or twisted.
6 Removing the tub and lev elling the product 30 mm x 4 1 2 3 4 5 5 1 2 3 4 5 3 DOUBLE MODELS 4 Ensure the tub is remov ed and then rotated counter-clockwise to prevent kinked hoses. Ensure product is level. U sing the most appropriate length Hexagonal socket supplied, and a screw driver , fully extend levelling feet up to r equired distance.
7 Securing the product and re tting the tub DOUBLE MODELS A 1 2 4 5 4 3 C C BB A 5 6 optional The mounting tabs are in pairs, one on each side of the product. At least two sets of tab pairs must be used. A and B tab pairs OR B and C tab pairs or all three pairs.
8 DishDraw er® and Standpipe Ø 38 mm W ater Pr essure Max Min W ater softener models 1 MPa (145 psi) 0.1 MP a (14.5 psi) Other models 1 MP a (145 psi) 0.03 MPa (4.3 psi) Drains will need to be separated to satisfy Kosher requir ements. W e suggest you confirm acceptability with your local Rabbi in respect to Kosher installations.
9 Plumbing and drainage - OPTION 1 (c onnec tion) DOUBLE MODELS 2 750- 882.5 mm 38 mm max. 120 mm 4 3 2 1 1 180 o 7 If space is limited for fixing, push hose through drain hose support to required hei.
10 DishDraw er® using sink trap with drain hose joiner Plumbing and drainage - OPTION 2 DOUBLE MODELS 750 - 882.5 mm Wa st e Va lv e Wa te r supply (COLD) Supplied drain hose joiner min.
11 Plumbing and drainage - OPTION 2 (c onnec tion) DOUBLE MODELS 2 3 750- 882.5 mm 1 4 3 2 1 180 o DishDraw er® using sink trap with drain hose joiner If space is limited for fixing, push hose through drain hose support to required height 7 8 Fit supplied washer Ensure hoses are rout ed straight to joiner .
12 F itting the toekick 1 2 3 4 5 6 7 8 9 10 19 9 10 DOUBLE MODELS Impor tant! D o not overtighten screw ..
13.
14 Pr oduc t dimensions A B C E D F G H J K L Pr oduct dimensions (mm) Pre nished L CD DS605 Pre nished Flat door DS605 Integrated DS605 A overall height* of product 409 409 409 B overall width of product 595 595 595 C overall depth of product (excl.
15 Cabinetry dimensions A B C D Cabinetry dimensions (mm) Pre nished LC D DS605 Pre nished Flat door DS605 Integrated DS605 A inside height of cavity 412 412 412 B inside width of cavity 600 600.
16 Ca vity preparation Cavit y These marks indicate mounting tab screw locations Note: T o align drawer front to adjacent cabinetry , the product to counter top clearance can be increased to 3 mm. Pref erred position. If adequate clearance, services hole can be higher .
17 SINGLE MODELS Route the hoses and mov e into the cavity 1 1 1 2 2 2 Tie together to a void kink ing 1 b 2 1 a Ensure hoses and cord are not kinked or twisted.
18 Removing the tub and securing the pr oduc t 2 30 mm 1 5 5 3 4 SINGLE MODELS 3 4 Ensure the tub is remov ed and then rotated counter-clockwise to prevent kinked hoses. The mounting tabs are in pairs, one on each side of the product. Ensure the sound insulation is repositioned correctly .
19 Re tting the tub 2 1 4 5 4 3 SINGLE MODELS 5 Before r efitting the tub, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward. Ensure the tub clips on both sides are reset. Ensure the tub is now rotated clockwise back.
20 DishDraw er® and Standpipe Ø 38 mm W ater Pr essure Max Min W ater softener models 1 MPa (145 psi) 0.1 MP a (14.5 psi) Other models 1 MP a (145 psi) 0.03 MPa (4.3 psi) Plumbing and drainage - OPTION 1 750 - 882.5 mm Wa st e Wa st e Va lv e Wa te r supply (C OLD) W aste disposal (optional) Do not connect to DishDrawer® min.
21 Plumbing and drainage - OPTION 1 (c onnec tion) 2 1 750- 882.5 mm 38 mm max. 120 mm 4 3 2 1 180 o DishDraw er® and Standpipe Ø 38 mm SINGLE MODELS If space is limited for fixing, push hose throug.
22 Plumbing and drainage - OPTION 2 DishDraw er® using sink trap with drain hose joiner 750 - 882.5 mm Va lv e Wa st e Wa te r supply (COLD) Supplied drain hose joiner min.
23 Plumbing and drainage - OPTION 2 (c onnec tion) 2 3 750- 882.5 mm 38 mm max. 120 mm 1 4 3 2 1 180 o DishDraw er® using sink trap with drain hose joiner SINGLE MODELS If space is limited for fixing.
24 F inal checklist Check all parts are installed. Ensure product is level, secur ely fastened to the cabinetry and opens and closes freely . The DishDrawer® must be free t o fully close with no resistance from the cabinetry . Ensure inlet hose to water supply has rubber washer fitted and is tight ened a fur ther half turn after seal contact.
.
Copyright © F isher & Pa ykel 2007. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at an y time.
An important point after buying a device Fisher & Paykel DD605 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Fisher & Paykel DD605 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Fisher & Paykel DD605 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Fisher & Paykel DD605 you will learn all the available features of the product, as well as information on its operation. The information that you get Fisher & Paykel DD605 will certainly help you make a decision on the purchase.
If you already are a holder of Fisher & Paykel DD605, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Fisher & Paykel DD605.
However, one of the most important roles played by the user manual is to help in solving problems with Fisher & Paykel DD605. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Fisher & Paykel DD605 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center