First Alert UL217

11 pages·749 KB·Carbon Monoxide Alarm·PDF·ENDEFRITNLJA
First Alert UL217
Table of Contents 37 sections USER’S MANUAL Smoke & Carbon Monoxide Alarm · INTRODUCTION · Model SC9120B Input: 120V AC ~ 60 Hz, 0.09A · LISTED TO UL 217 and · … ShowHide
Page 3 of the First Alert UL217 user manual — 7. ACTIVATING THE BATTERY BACK-UP
Page 3 · click to enlarge
Page 3

INSTALLATION, Continued

BEFORE YOU BEGIN INSTALLATION This unit is designed to be mounted on any standard wiring junction box up to a 4-inch (10 cm) size, on either the ceiling or wall. Read “Where to Install This Alarm” and “Where This Alarm Should Not Be Installed ” before you begin installation.

  • STAND ALONE ALARM ONLY:
  • Connect the white wire on the power connector to the neutral wire in the junction box.
  • Connect the black wire on the power connector to the hot wire in the junction box.
  • Tuck the orange wire inside the junction box. It is used for interconnect only.
  • Make sure the alarm is not receiving excessively noisy power. Examples of noisy power could be major appliances on the same circuit, power from a generator or solar power, light dimmer on the same circuit or mounted near fluorescent lighting. Excessively noisy power may cause damage to your Alarm.
  • INTERCONNECTED ALARMS ONLY: Strip off about 1/2” of the plastic coating on the orange interconnect wire on the power connector.
  • Connect the white wire on the power connector to the neutral wire (usually white) in the junction box.
  • Connect the black wire on the power connector to the hot wire (usually black) in the junction box.
  • Connect the orange wire on the power connector to the interconnect wire in the junction box. Repeat for each unit you are interconnecting. Never connect the hot or neutral wires in the junction box to the orange interconnect wire. Never cross hot and neutral wires between interconnected Alarms.

Find the pair of self-adhesive labels included with this Smoke/CO Alarm.

  • On each label write in the phone number of your emergency responder (like 911) and a qualified appliance technician.
  • Place one label near the Smoke/CO Alarm, and the other label in the “fresh air” location you plan to go if the alarm sounds.

3. Plug the power connector into the back of the Smoke/CO Alarm. 4. Position the base of the Smoke/CO Alarm over the mounting bracket and turn. The Alarm will remain secure over a wide rotation range to allow for perfect alignment. When wall mounting, this will allow fine- tuning on the positioning to compensate for out of aligned wall studs and to keep the wording level. The Alarm can be positioned over the bracket every 120°. Rotate the Alarm until aligned properly. 5. Check all connections.

PARTS OF THIS SMOKE/CO ALARM

2 Mounting Slot and Screw*

3 Locking Pins (break out of bracket)

STAND ALONE ALARM ONLY: • If you are only installing one unit, restore power to the junction box.

4 Hot (Black) AC Wire

5 Neutral (White) AC Wire

INTERCONNECTED ALARMS ONLY: • If you are interconnecting multiple Smoke/CO Alarms, repeat Step 1-5 for each Smoke/CO Alarm in the series. When you are finished, restore power to the junction box.

6 Interconnect Wire (Orange)

7 Lever to Open Battery Compartment

8 Swing-Out Battery Compartment

ELECTRICAL SHOCK HAZARD. Do not restore power until all Alarms are completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death.

6. Make sure the Smoke/CO Alarm is receiving AC power. Under normal operation, the green indicator light will shine continuously. If the green power indicator light does not light, TURN OFF POWER TO THE JUNCTION BOX and recheck all connections. If all connections are correct and the green power indicator still does not light when you restore the power, the unit should be replaced immediately.

HOW TO INSTALL THIS SMOKE/CO ALARM

Tools you will need: Standard Flathead screwdriver, wire strippers.

7. ACTIVATING THE BATTERY BACK-UP

ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical shock, injury or death.

Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. You do not need to open the battery compartment and reposition the battery during installation. DO NOT remove the battery activation tab until AC power is turned on to conserve battery power.

To install this unit: 1. Remove the mounting bracket from the base. Position the screw slots on the mounting bracket over the screws in the junction box. Tighten the screws.

8. Single Station Alarms: Test each Alarm. Press and hold the Test/Silence button until you hear the acknowledge “chirp” or the unit alarms. Interconnected Alarms: Press and hold the Test/Silence button until the unit alarms. All interconnected Alarms should sound. The other Alarms sounding only tests the interconnect signal between Alarms. It does not test each Alarm’s operation. You must test each Alarm individually to check if the Alarm is functioning properly.

Improper wiring of the power connector or the wiring leading to the power connector will cause damage to the Alarm and may lead to a non-functioning Alarm.

2. Using wire nuts, connect the power connector to the AC power.

If any unit in the series does not alarm during testing, TURN OFF POWER, REMOVE BATTERIES, and recheck connections. If it does not alarm when you restore power, replace it immediately.

1 Mounting Bracket · 9 Quick-Connect Power · *Not Included

Page 4 of the First Alert UL217 user manual — A B } }
Page 4 · click to enlarge
Page 4

INSTALLATION, Continued

SPECIAL REQUIREMENTS FOR INTERCONNECTED ALARMS

  • Failure to meet any of the above requirements could damage the units and cause them to malfunction, removing your protection.
  • AC and AC/DC Smoke/CO Alarms can be interconnected. Under AC power, all units will alarm when one senses smoke or CO. When power is interrupted, only the AC/DC units in the series will continue to send and receive signals. AC powered Smoke/CO Alarms will not operate. See “Smart Interconnect” Feature.

Interconnected units can provide earlier warning of a Smoke/CO problem than stand-alone units, especially if the problem starts in a remote area of the dwelling. If any unit in the series senses Smoke/CO, all units will alarm. To determine which Smoke/CO Alarm initiated an alarm, refer to the table.

During an AlarmOn Initiating Alarm(s) – Red LED(s) flashes (flash) rapidly

On All Other Alarms – Red LED is Off

After an Alarm (Latching):

On Initiating Alarm(s) – Green LED(s) On, Red LED(s) flash once every 5 seconds

On All Other Alarms – Green LED(s) On, Red LED(s) is Off

Interconnect units within a single family residence only. Otherwise all households will experience unwanted alarms when you test any unit in the series. Interconnected units will only work if they are wired to compatible units and all requirements are met. This unit is designed to be compatible with: BRK Electronics® Smoke Alarm Models 9120, 9120B, 7010, 7010B, 7020B, 4120, 4120B, 4120SB, 4919, 2002RAC, 100S, 5919, 5919TH; BRK Electronics® Heat Alarm Models HD6135F, HD6135FB; BRK Electronics® CO Alarm Models CO5120BN, CO5120PDBN; Smoke/CO Alarm Model SC6120B, SC9120B; and First Alert® Smoke Alarm Models SA4120, SA4120B, SA4121B, SA4919B, SA100B, SC7010B, SC7010BV; Accessory devices models RM3, RM4, SL177.

Interconnected units must meet ALL of the following requirements:

  • A maximum of 18 compatible BRK Electronics ® Smoke, Heat or CO Alarms may be interconnected. No more than 12 of the 18 can be Smoke Alarms per NFPA 72.
  • The same fuse or circuit breaker must power all interconnected units.
  • The total length of wire interconnecting the units should be less than 1000 feet (300 meters). This type of wire is commonly available at Hardware and Electrical Supply stores.
  • All wiring must conform to all local electrical codes and NFPA 70 of the National Electrical Code. Refer to NFPA 72, NFPA 101, and/or your local building code for further connection requirements.

A B } }

6 7 8

A. Unswitched 120VAC B. To Additional Alarms, 60 Hz source Maximum = 18 Alarms

1. Smoke/CO Alarm 2. Ceiling or Wall 3. Power Connector
4. Wire Nut 5. Junction Box 6. Neutral Wire (White)
7. Interconnect Wire (Orange) 8. Hot Wire (Black)

Compatible Interconnected Units

Page 5 of the First Alert UL217 user manual — TO PERMANENTLY REMOVE THE BRACKET LOCK:
Page 5 · click to enlarge
Page 5

USING THE OPTIONAL LOCKING FEATURES

The optional locking features are designed to discourage unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or alarm removal is not a concern. These Smoke/CO Alarms have two separate locking features: one locks the battery compartment, and the other locks the Smoke/CO Alarm to the mounting bracket. You can choose to use either feature independently, or use them both. Tools you will need: • Needle-nose pliers or utility knife

  • Standard/Flathead screwdriver.

Both locking features use locking pins, molded into the mounting bracket. Using needle nose pliers or a utility knife, remove one or both pins, depending on which locking features you use.

THE BATTERY COMPARTMENT LOCK

TO LOCK THE BATTERY COMPARTMENT:

TO UNLOCK THE BATTERY COMPARTMENT:

Do not lock the battery compartment until you have activated the battery and tested the battery back-up.

Once the Smoke/CO Alarm is installed, you must disconnect it from the AC power before unlocking the battery compartment.

1. Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. Push and hold the test button on the Smoke/CO Alarm’s cover until the alarm sounds: 4 beeps, pause, 4 beeps, pause, 3 beeps, pause, 3 beeps, pause.

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Smoke/CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury or death.

1. Remove the Smoke/CO Alarm from the mounting bracket. If the unit is locked to the bracket, see the section “To Deactivate the Locking Feature.”

If the unit does not alarm during testing, DO NOT lock the battery compartment! Install a new battery and test again. If it still does not alarm, replace the Smoke/CO Alarm immediately.

2. Disconnect the power connector by gently prying it away from the back of the Smoke/CO Alarm.
3. Insert a flathead screwdriver under the head of the locking pin, and gently pry it out of the battery compartment lock. (If you plan to re-lock the battery compartment, save the locking pin.)
2. Using needle-nose pliers or a utility knife, detach one locking pin from the mounting bracket.
4. To re-lock the battery compartment, close the battery door and reinsert the locking pin in the lock.
3. Push the locking pin through the black dot on the label on the back of the Smoke/CO Alarm.
5. Reconnect the power connector to the back of the Smoke/CO Alarm, reattach the Smoke/CO Alarm to the mounting bracket, and restore the power.

When replacing the battery, always test the Smoke/CO Alarm before re-locking the battery compartment.

THE MOUNTING BRACKET LOCK

TO ACTIVATE THE BRACKET LOCK: 1. Using needle-nose pliers, detach one locking pin from the mounting bracket.

TO DEACTIVATE THE BRACKET LOCK:

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Smoke/CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury or death.

2. Insert the locking pin into the lock located on the base as shown in the diagram.
3. When you attach the Smoke/CO Alarm to the mounting bracket, the locking pin’s head will fit into a notch on the bracket.

Always discharge the branch circuit before servicing an AC or AC/DC Smoke/CO Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Smoke/CO Alarms with battery back-up. Finally, press and hold the test button. 1. Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket. 2. Pry the Smoke/CO Alarm away from the bracket by turning both the screwdriver and the Smoke/CO Alarm counterclockwise (left) at the same time.

TO PERMANENTLY REMOVE THE BRACKET LOCK:

Insert the flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.

Battery Drawer Lock · Locking Pin · Mounting Bracket Lock

Page 6 of the First Alert UL217 user manual — “LATCHING” ALARM INDICATOR
Page 6 · click to enlarge
Page 6

HOW YOUR SMOKE/CO ALARM WORKS

WHAT TO DO IF CARBON MONOXIDE IS DETECTED

THE COVER OF YOUR SMOKE/CO ALARM

“ALARM-MOVE TO FRESH AIR”

1. Test/Silence Button: Press and hold to activate test, or to silence the alarm.

If you hear the alarm horn sound 4 beeps, pause, 4 beeps, pause, and the RED CO light is flashing, move everyone to a source of fresh air.

2. POWER Light (GREEN)/ SMOKE ALARM Light (RED)
3. CO ALARM Light (RED)

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!

4. Battery Drawer
5. (Behind the Cover) Alarm Horn: 85dB audible alarm for test, alarm, and unit malfunction warning.

IF THE CO ALARM SOUNDS: 1. Operate the Test/Silence button.

2. Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

UNDERSTANDING THE LIGHT AND HORN PATTERNS

3. Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your Smoke/CO Alarm remains in its normal condition.

Condition LED (Red or Green Lights)

POWER UP Green LED flashes ON once, then shines continuously

4. After following steps 1-3, if your Smoke/CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:

DURING TESTING Smoke & CO Red LEDs flash once every second during their respective repetitive horn patterns

Horn pattern(Smoke) 3 beeps, pause, 3 beeps, pause; (CO) 4 beeps, pause, 4 beeps, pause

LOW OR MISSING BATTERY

Green LED flashes (with horn)

Horn “chirps” about once a minute

ALARM CONDITION Interconnected Series of Smoke/CO Alarms

Smoke or CO Red LED flashes rapidly on the unit that triggered the alarm.

Horn pattern: (CO) 4 beeps, pause, 4 beeps, pause repeating on all CO Alarms and “Smart Interconnect” Alarms; (Smoke) 3 beeps, pause, 3 beeps, pause repeating on all Smoke, Heat, and “Smart Interconnect” Alarms

WHAT TO DO IF SMOKE IS DETECTED

If you hear the alarm horn sound 3 beeps, pause, 3 beeps, pause and the RED SMOKE light is flashing, smoke has been detected. Evacuate everyone from the building.

LEDs on the other alarms in an interconnected series will not flash.

  • If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death.
  • Never disconnect the AC power to quiet an unwanted alarm. Disconnecting the power disables the Alarm so it cannot sense smoke. This will remove your protection. Instead, open a window or fan the smoke away from the unit. The Alarm will reset automatically.
  • If the unit alarms get everyone out of the house immediately.

IN ALARM SILENCE MODE

Red Smoke or CO LED flashes once every second on initiating unit

Horn remains silent: CO for 4 minutes; Smoke for up to 15 minutes. Horn will sound if Smoke or CO levels increase.

“LATCHING” ALARM INDICATOR

Red Smoke and/or CO LED flashes once every 5 seconds

  • ELECTRICAL SHOCK HAZARD: Attempting to disconnect the power connector from the unit when the power is on may result in electrical shock, serious injury or death.

MALFUNCTION Green LED flashes 3 times synchro- nized with 3 rapid chirps

Horn sounds 3 consecutive rapid chirps every minute

When an interconnected system of AC powered units is in alarm, the alarm indicator light on the unit(s) that initiated the alarm will blink rapidly. It will remain OFF on any remaining units.

If the unit alarms, get everyone out of the dwelling immediately.

If the unit alarms and you are certain that the source of smoke is not a fire—cooking smoke or an extremely dusty furnace, for example—open a nearby window or door and fan the smoke away from the unit. Use the Silence Feature to silence the Alarm. This will silence the alarm, and once the smoke clears the unit will reset itself automatically.

IF YOUR SMOKE/CO ALARM SOUNDS WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM Type of Alarm What You See and Hear

Carbon Monoxide CO Light(CO) Flashing RED Horn: 4 beeps, pause, 4 beeps, pause
Smoke Smoke LightFlashing RED Horn: 3 beeps, pause, 3 beeps, pause
Show 5 more labels / short text on this page
_____________________________________________________________ · Horn · Horn remains silent · _____________________________________________________________ · Horn remains silent
Page 7 of the First Alert UL217 user manual — REGULAR MAINTENANCE
Page 7 · click to enlarge
Page 7
  • WHAT TO DO IN CASE OF FIRE
  • Don’t panic; stay calm. Follow your family escape plan.
  • Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.
  • Feel doors with the back of your hand before opening them. If a door is cool, open it slowly. Don’t open a hot door. Keep doors and windows closed, unless you must escape through them.
  • Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.
  • Meet at your planned meeting place outside your home, and do a head count to make sure everybody got out safely.
  • Call the Fire Department as soon as possible from outside. Give your address, then your name.
  • Never go back inside a burning building for any reason.
  • Contact your Fire Department for ideas on making your home safer.

WEEKLY TESTING

  • NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to your home. The built-in test switch accurately tests the unit’s operation as required by Underwriters Laboratories, Inc. (UL). NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.
  • DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.

It is important to test this unit every week to make sure it is working properly. Using the test button is the recommended way to test this Smoke/CO Alarm. 1. Push and hold the Test/Silence button on the cover until you hear a “chirp.” The “chirp” marks the start of the self-test sequence. 2. During testing, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause, while the red smoke LED flashes. Then you will hear a loud, repeating horn pattern: 4 beeps, pause, 4 beeps, pause, while the red CO LED flashes. 3. When testing a series of interconnected units you must test each unit individually. Make sure all units alarm when each one is tested.

Alarms have various limitations. See "General Limitations of Smoke/CO Alarms" for details.

“SMART INTERCONNECT” FEATURE This Alarm includes "Smart Interconnect" which enables the Alarm to be interconnected with other BRK Smoke, Heat, and "Smart Interconnect" CO Alarms. When smoke is detected, all Alarms will sound the smoke horn pattern. When CO is detected, "Smart Interconnect" Alarms will sound the CO horn pattern. Alarms that do not have the "Smart Interconnect" Feature will remain silent during a CO alarm.

If the Smoke/CO Alarm does not test properly: 1. Make sure the AC power is applied and battery is fresh and installed correctly. 2. Be sure the alarm is clean and dust-free. 3. Test the unit again. If the Smoke/CO Alarm is still not working properly, replace it immediately. Refer to the “Limited Warranty” at the end of this manual.

USING THE SILENCE FEATURE

NEVER disconnect the power to your Smoke/CO Alarm to silence the horn—use the Silence Feature. Disconnecting the Smoke/CO Alarm removes your protection! If the unit will not silence or if it stays in silence mode continuously, it should be replaced immediately.

  • The Silence Feature is intended to temporarily silence the horn while you identify and correct the problem. Do not use the Silence Feature in emergency situations. It will not correct a CO problem or extinguish a fire.
  • To use the Silence Feature, press the Test/Silence button until you hear the acknowledge “chirp” or until the horn is silent.
  • If the Test/Silence button is pressed while the Smoke/CO Alarm is in the silence mode, the alarm will start sounding again. To silence Alarms in an interconnected series: To silence an interconnected series of Smoke/CO Alarms, you must press the Test/Silence button on the initiating alarm (The unit with the flashing red light; the red light will be off on all other Alarms.). If you press the Test/Silence on any other Alarm, it will only silence that unit, not the whole interconnected series.

If there is still a problem, do not try to fix the Alarm yourself. This will void your warranty!

REGULAR MAINTENANCE

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge. This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working properly:

  • Test it at least once a week.
  • Clean the Smoke/CO Alarm at least once a month; gently vacuum the outside of the Smoke/CO Alarm using your household vacuum’s soft brush attachment. Test the Smoke/CO Alarm. Never use water, cleaners or solvents since they may damage the unit.
  • If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately.
  • Relocate the unit if it sounds frequent unwanted alarms. See “Where This Alarm Should Not Be Installed” for details.
  • When the battery back-up becomes weak, the Alarm will “chirp” about once a minute (the low battery warning). This warning should last 7 days, but you should replace the battery immediately to continue your protection. This Alarm must have AC or battery power to operate. If AC power fails, and the battery is dead or missing, the Alarm cannot operate.

WHEN THE SMOKE ALARM IS SILENCED... The Smoke Alarm will remain silent for up to 15 minutes and then return to normal operation. If the smoke has not cleared within the silence period or if smoke increases to a critical level during the silence period, the unit will go back into alarm.

Use the Silence Feature only if you are certain of the source of smoke. If you are not certain of the source or a fire starts while you are clearing smoke, evacuate the house immediately. Not responding to an alarm can result in property loss, injury, or death.

WHEN THE CO ALARM IS SILENCED... The CO Alarm will remain silent for 4 minutes. While the Alarm is silenced, it will continue to monitor the air for CO. After 4 minutes, if CO levels remain potentially dangerous the horn will start sounding again.

DO NOT spray cleaning chemicals or insect sprays directly on or near the Alarm. DO NOT paint over the Alarm. Doing so may permanently damage the Alarm.

The Silence Feature is intended to temporarily silence the Alarm horn. It will not correct a CO problem.

LOW BATTERY SILENCE FEATURE This Silence Feature can temporarily quiet the low battery warning “chirp” for up to 8 hours if AC power is present. Press the Test/Silence button on the Alarm cover until you hear the acknowledge “chirp”. Once the low battery warning “chirp” silence feature is activated, the unit continues to flash the green light once a minute for 8 hours. After 8 hours, the low battery “chirp” will resume. The Alarm will continue to operate as long as AC power is supplied. However, replace the battery as soon as possible, to maintain protection in event of a power outage.

CHOOSING A REPLACEMENT BATTERY: Your Smoke/CO Alarm requires one standard 9V battery. The following batteries are acceptable as replacements: Duracell #MN1604, (Ultra) #MX1604; Eveready (Energizer) #522. These batteries are available at many local retail stores.

Actual battery service life depends on the Smoke/CO Alarm and the environment in which it is installed. All the batteries specified above are acceptable replacement batteries for this unit. Regardless of the manufacturer’s suggested battery life, you MUST replace the battery immediately once the unit starts “chirping” (the “low battery warning”).

THE “LATCHING ALARM” INDICATOR: The Latching Alarm Indicator is activated after an Alarm is exposed to alarm levels of smoke or carbon monoxide. This feature will only work with AC power. After smoke or CO levels drop below alarm levels, the red smoke or CO LED will begin to flash once every 5 seconds. It will continue to flash or “latch” until you clear it by testing the alarm. This feature helps emergency responders, investigators, or service technicians identify which unit(s) in your home were exposed to alarm levels of smoke or carbon monoxide. This can help investigators pinpoint the source of smoke or CO. Interconnected Alarms. Latching Alarm Indicator shows which Alarm(s) in the series were exposed to alarm levels of smoke or carbon monoxide. The Latching Alarm Indicator stays ON until you clear it, so it can alert you to an alarm that occurred while you were away from home, even though smoke or CO present in the air has dropped below alarm levels.

Page 8 of the First Alert UL217 user manual — REGULATORY INFORMATION FOR CO ALARMS
Page 8 · click to enlarge
Page 8

WHAT YOU NEED TO KNOW ABOUT CO

HOW CAN I PROTECT MY FAMILY FROM CO POISONING? A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before Carbon Monoxide levels become threatening for average, healthy adults.

WHAT IS CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO. These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane. Common appliances are often sources of CO. If they are not properly maintained, are improperly ventilated, or malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient. “Air-tight” homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.

A CO Alarm is not a substitute for proper maintenance of home appliances. To help prevent CO problems and reduce the risk of CO poisoning:

  • Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow. Also, have a professional check for rust and corrosion, cracks, or separations. These conditions can prevent proper air movement and cause backdrafting. Never “cap” or cover a chimney in any way that would block air flow.
  • Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC companies offer appliance inspections for a nominal fee.
  • Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust and scaling. Also check the flame on the burner and pilot lights. The flame should be blue. A yellow flame means fuel is not being burned completely and CO may be present. Keep the blower door on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are vented to the outside. Do not grill or barbecue indoors, or in garages or on screen porches.
  • Check for exhaust backflow from CO sources. Check the draft hood on an operating furnace for a backdraft. Look for cracks on furnace heat exchangers.
  • Check the house or garage on the other side of shared wall.
  • Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a window or a door. Opening windows and doors can significantly decrease CO levels.

SYMPTOMS OF CO POISONING These symptoms are related to CO POISONING and should be discussed with ALL household members. Mild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms). Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate. Extreme Exposure: Convulsions, unconsciousness, heart and lung failure. Exposure to Carbon Monoxide can cause brain damage, death.

This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults. Why is this important? Because you need to be warned of a potential CO problem while you can still react in time. In many reported cases of CO exposure, victims may be aware that they are not feeling well, but become disoriented and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!

In addition, familiarize yourself with all enclosed materials. Read this manual in its entirety, and make sure you understand what to do if your CO Alarm sounds.

REGULATORY INFORMATION FOR SMOKE/CO ALARMS

FINDING THE SOURCE OF CO AFTER AN ALARM Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of CO after an alarm. These are a few of the factors that can make it difficult to locate sources of CO:

REGULATORY INFORMATION FOR CO ALARMS

WHAT LEVELS OF CO CAUSE AN ALARM? Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to levels of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over time (in minutes).

  • House well ventilated before the investigator arrives.
  • Problem caused by “backdrafting.”
  • Transient CO problem caused by special circumstances. Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.

UL2034 Required Alarm Points*:

  • If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES.
  • If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.
  • If the alarm is exposed to 70 ppm if CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.

POTENTIAL SOURCES OF CO IN THE HOME Fuel-burning appliances like: portable heater, gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer.

First Alert UL217 — REGULATORY INFORMATION FOR CO ALARMS diagram (page 8)
Fig. 1

* Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH). The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.

Damaged or insufficient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked or clogged chimney opening.

  • CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume it’s not present.
  • An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.
  • An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours.

Improper use of appliance/device: operating a barbecue grill or vehicle in an enclosed area (like a garage or screened porch).

Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034. According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and is designed to alarm before CO levels become life threatening. This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained as described in this manual.

Transient CO Problems: “transient” or on-again-off-again CO problems can be caused by outdoor conditions and other special circumstances.

  • The following conditions can result in transient CO situations: 1. Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
  • Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air with extended periods between cycles).
  • Negative pressure differential resulting from the use of exhaust fans.
  • Several appliances running at the same time competing for limited fresh air.
  • Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
  • Obstructions in or unconventional vent pipe designs which can amplify the above situations. 2. Extended operation of unvented fuel burning devices (range, oven, fireplace). 3. Temperature inversions, which can trap exhaust close to the ground. 4. Car idling in an open or closed attached garage, or near a home. These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come and go, they are also hard to recreate during a CO investigation.

Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically.

Audible Alarm: 85dB minimum at 10 feet (3 meters).

Page 9 of the First Alert UL217 user manual — WHAT YOU NEED TO KNOW ABOUT CO
Page 9 · click to enlarge
Page 9
BOUT SMOKE ALARMS ttery (DC) operated Smoke Alarms: Provide protection even when ctricity fails, provided the batteries are fresh and correctly installed. its are easy to install, and do not require professional installation. wever, they do not provide interconnected functionality. C powered Smoke Alarms: Can be interconnected so if one unit nses smoke, all units alarm. They do not operate if electricity fails. C with battery (DC) back-up: will operate if electricity fails, provided e batteries are fresh and correctly installed. AC and AC/DC units ust be installed by a qualified electrician. ireless Interconnected Alarms: Offer the same interconnected nctionality as with hardwired alarms, without wires. Units are easy install and do not require professional installation. They provide otection even when electricity fails, provided the batteries are fresh d correctly installed. moke Alarms for Solar or Wind Energy users and battery backup wer systems: AC powered Smoke Alarms should only be operated th true or pure sine wave inverters. Operating this Smoke Alarm with ost battery-powered UPS (uninterruptible power supply) products or uare wave or “quasi sine wave” inverters will damage the Alarm. you are not sure about your inverter or UPS type, please consult with e manufacturer to verify. moke Alarms for the hearing impaired: Special purpose Smoke arms should be installed for the hearing impaired. They include a ual alarm and an audible alarm horn, and meet the requirements of e Americans With Disabilities Act. These units can be interconnected if one unit senses smoke, all units alarm. moke alarms are not to be used with detector guards unless the mbination has been evaluated and found suitable for that purpose. these Smoke Alarms are designed to provide early warning of fires if ated, installed and cared for as described in the user’s manual, and if oke reaches the Alarm. If you are unsure which type of unit to install, er to NFPA (National Fire Protection Association) 72 (National Fire arm Code) and NFPA 101 (Life Safety Code). National Fire Protection sociation, One Batterymarch Park, Quincy, MA 02269-9101. Local ilding codes may also require specific units in new construction in different areas of the home. PECIAL COMPLIANCE CONSIDERATIONS is unit alone is not a suitable substitute for complete fire tection systems in places housing many people—like apartment ildings, condominiums, hotels, motels, dormitories, hospitals, ng-term health care facilities, nursing homes, day care facilities, group homes of any kind—even if they were once single-family mes. It is not a suitable substitute for complete fire detection stems in warehouses, industrial facilities, commercial buildings, ING SMOKE ALARMS IN MOBILE HOMES & m security install one Smoke Alarm as close to each sleeping ssible. For more security, put one unit in each room. Many le homes (especially those built before 1978) have little or no If your mobile home is not well insulated, or if you are unsure unt of insulation, it is important to install units on inside walls e Alarms should be installed where temperatures normally ween 40˚ F (4˚ C) and 100˚ F (38˚ C). WARNING: Test units s after the vehicle has been in storage, before every trip, a week while in use. Failure to test units used in RVs as may remove your protection. ment should be installed in accordance with NFPA (National tion Association) 72 and 101. National Fire Protection , One Batterymarch Park, Quincy, MA 02269-9101. Additional ing and regulatory codes may apply in your area. Always pliance requirements before beginning any installation. Y PLACEMENT RECOMMENDATIONS National Fire Code) rms shall be installed in each separate sleeping room, outside ing area in the immediate vicinity of the bedrooms and on each tory of the family living unit, including basements and excluding es and unfinished attics. struction, Alarms shall be so arranged that operation of any shall cause the operation of all Alarms within the dwelling. tection-Are More Smoke Alarms Desirable? The required Smoke Alarms might not provide reliable early warning for those areas separated by a door from the areas protected ired Smoke Alarms. For this reason, it is recommended that older consider the use of additional Smoke Alarms for those creased protection. The additional areas include the baseooms, dining room, furnace room, utility room, and hallways ed by the required Smoke Alarms. The installation of Smoke itchens, attics (finished or unfinished), or garages is not commended, as these locations occasionally experience that can result in improper operation. State Fire Marshal (CSFM) ng detection is best achieved by the installation of fire detection in all rooms and areas of the household as follows: A Smoke lled in each separate sleeping area (in the vicinity, but outside and Heat or Smoke Alarms in the living rooms, dining rooms, kitchens, hallways, finished attics, furnace rooms, closets, utility e rooms, basements, and attached garages.and special-purpose non-residential buildings which require special fire detection and alarm systems. Depending on the building codes in your area, this unit may be used to provide additional protection in these facilities. The following information applies to all four types of buildings listed below: In new construction, most building codes require the use of AC or AC/DC powered Smoke Alarms only. AC, AC/DC, or DC powered Smoke Alarms can be used in existing construction as specified by local building codes. Refer to NFPA 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code), local building codes, or consult your Fire Department for detailed fire protection requirements in buildings not defined as “households.” 1. Single-Family Residence: Single family home, townhouse. It is recommended this unit be installed on every level of the home, in every bedroom, and in each bedroom hallway. 2. Multi-Family or Mixed Occupant Residence: Apartment building, condominium. This unit is suitable for use in individual apartments or condos, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this unit in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/ regulations. 3. Institutions: Hospitals, day care facilities, long-term health care facilities. This unit is suitable for use in individual patient sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this unit in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations. 4. Hotels and Motels: Also boarding houses and dormitories. This unit is suitable for use inside individual sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this unit in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations.d special-purpose non-residential buildings which require special e detection and alarm systems. Depending on the building codes your area, this unit may be used to provide additional protection these facilities. e following information applies to all four types of buildings listed low: new construction, most building codes require the use of AC or /DC powered Smoke Alarms only. AC, AC/DC, or DC powered moke Alarms can be used in existing construction as specified by cal building codes. Refer to NFPA 72 (National Fire Alarm Code) and PA 101 (Life Safety Code), local building codes, or consult your Fire partment for detailed fire protection requirements in buildings not fined as “households.” Single-Family Residence: ngle family home, townhouse. It is recommended this unit be installed every level of the home, in every bedroom, and in each bedroom llway. Multi-Family or Mixed Occupant Residence: artment building, condominium. This unit is suitable for use in individual artments or condos, provided a primary fire detection system already ists to meet fire detection requirements in common areas like lobbies, llways, or porches. Using this unit in common areas may not provide fficient warning to all residents or meet local fire protection ordinances/ gulations. Institutions: spitals, day care facilities, long-term health care facilities. This unit is itable for use in individual patient sleeping/resident rooms, provided primary fire detection system already exists to meet fire detection quirements in common areas like lobbies, hallways, or porches. ing this unit in common areas may not provide sufficient warning to residents or meet local fire protection ordinances/regulations. Hotels and Motels: so boarding houses and dormitories. This unit is suitable for use ide individual sleeping/resident rooms, provided a primary fire tection system already exists to meet fire detection requirements common areas like lobbies, hallways, or porches. Using this unit in mmon areas may not provide sufficient warning to all residents or eet local fire protection ordinances/regulations. 9
Page 10 of the First Alert UL217 user manual — TROUBLESHOOTING GUIDE
Page 10 · click to enlarge
Page 10
GENERAL LIMITATIONS OF SMOKE/CO ALARMS This Smoke/CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for Carbon Monoxide Alarms must be met. The Smoke Alarm portion of this device is not intended to alert hearing impaired residents. Special purpose Smoke Alarms should be installed for hearing impaired residents (CO Alarms are not yet available for the hearing impaired). Smoke/CO Alarms may not waken all individuals. Practice the escape plan at least twice a year, making sure that everyone is involved – from kids to grandparents. Allow children to master fire escape planning and practice before holding a fire drill at night when they are sleeping. If children or others do not readily waken to the sound of the Smoke/CO Alarm, or if there are infants or family members with mobility limitations, make sure that someone is assigned to assist them in fire drill and in the event of an emergency. It is recommended that you hold a fire drill while family members are sleeping in order to determine their response to the sound of the Smoke/CO Alarm while sleeping and to determine whether they may need assistance in the event of an emergency. Smoke/CO Alarms cannot work without power. Battery operated units cannot work if the batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or AC power, install both types of units. This Smoke/CO Alarm will not sense smoke or CO that does not reach the sensors. It will only sense smoke or CO at the sensor. Smoke or CO may be present in other areas. Doors or other obstructions may affect the rate at which CO or smoke reaches the sensors. If bedroom doors are usually closed at night, we recommend you install an alarm device (Combination CO and Smoke Alarm, or separate CO Alarms and Smoke Alarms) in each bedroom and in the hallway between them. This Smoke/CO Alarm may not sense smoke or CO on another level of the home. Example: This alarm device, installed on the second floor, may not sense smoke or CO in the basement. For this reason, one alarm device may not give adequate early warning. Recommendedminimum protection is one alarm device in every sleeping area, every bedroom, and on every level of your home. Some experts recommend battery powered Smoke and CO Alarms be used in conjunction with interconnected AC powered Smoke Alarms. For details, see “About Smoke Alarms” for details. Smoke/CO Alarms may not be heard. The alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if the Smoke/CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This Smoke/CO Alarm is not intended for people who are hearing impaired. The Alarm may not have time to alarm before the fire itself causes damage, injury, or death, since smoke from some fires may not reach the unit immediately. Examples of this include persons smoking in bed, children playing with matches, or fires caused by violent explosions resulting from escaping gas. This Smoke/CO Alarm is not a substitute for life insurance. Though this Smoke/CO Alarm warns against increasing CO levels or the presence of smoke, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives. Homeowners and renters must still insure their lives. This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test this device weekly. The unit should be replaced immediately if it is not operating properly. This Smoke/CO Alarm is not foolproof. Like all other electronic devices, this Smoke/CO Alarm has limitations. It can only detect smoke or CO that reaches the sensors. It may not give early warning of the source of smoke or CO is in a remote part of the home, away from the alarm device.minimum protection is one alarm device in every sleeping area, every bedroom, and on every level of your home. Some experts recommend battery powered Smoke and CO Alarms be used in conjunction with interconnected AC powered Smoke Alarms. For details, see “About Smoke Alarms” for details. Smoke/CO Alarms may not be heard. The alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if the Smoke/CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This Smoke/CO Alarm is not intended for people who are hearing impaired. The Alarm may not have time to alarm before the fire itself causes damage, injury, or death, since smoke from some fires may not reach the unit immediately. Examples of this include persons smoking in bed, children playing with matches, or fires caused by violent explosions resulting from escaping gas. This Smoke/CO Alarm is not a substitute for life insurance. Though this Smoke/CO Alarm warns against increasing CO levels or the presence of smoke, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives. Homeowners and renters must still insure their lives. This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test this device weekly. The unit should be replaced immediately if it is not operating properly. This Smoke/CO Alarm is not foolproof. Like all other electronic devices, this Smoke/CO Alarm has limitations. It can only detect smoke or CO that reaches the sensors. It may not give early warning of the source of smoke or CO is in a remote part of the home, away from the alarm device.

TROUBLESHOOTING GUIDE

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Alarm is installed BEFORE removing it from the mounting bracket or checking any electrical connections! Failure to turn off the power first may result in serious electrical shock, injury or death.

your Alarm does this...It means...You should... reen light is OFF. Unit will not alarm when you ress the Test/Silence button.Unit may not be receiving any power.Check the AC power supply. Make sure the power connector is securely attached to the alarm. Make sure a fresh 9V battery is installed to power the battery back-up*. reen light flashes ON, once a minute (horn is lent).Alarm is not receiving AC power.Unit is operating on battery back-up. Check the AC power supply. nce a minute, the Green light flashes and the orn “chirps”.Low battery warning. Battery is low or missing.Replace the battery, avoid interrupting AC power. nce a minute, the alarm sounds 3 quick hirps”, and the green light flashes quickly ree times.MALFUNCTION SIGNAL. Unit needs to be replaced. Based on self-diagnostic tests, the unit has detected a fault.Units under warranty should be returned to manufacturer for replacement. See “Limited Warranty” for details. arm goes back into alarm after you pressed e Test/Silence button to silence an alarm.Smoke and/or CO levels are still potentially dangerous.Refer to “If Your Smoke/CO Alarm Sounds” for details on how to respond to an alarm. If anyone is feeling ill, EVACUATE your home immediately and call 911. arm sounds frequently even though no high vels of smoke or CO are revealed in an vestigation.The Alarm may be improperly located. Refer to “Where to Install This Alarm.”Relocate your alarm. If frequent alarms continue, have home rechecked for potential problems. You may be experiencing an intermittent smoke or CO problem. or a list of acceptable replacement batteries, see “Regular Maintenance.” you have any questions that cannot be answered by reading this manual, call Consumer Affairs: 1-800-323-9005.
Page 11 of the First Alert UL217 user manual — LIMITED WARRANTY
Page 11 · click to enlarge
Page 11

LIMITED WARRANTY

BRK Brands, Inc., ("BRK") the maker of BRK® brand and First Alert® brand products, warrants that for a period of five years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty.

This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change the terms and conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.

How to Obtain Warranty Service Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when calling. For Warranty Service return to: BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906

Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with respect to battery.

For your records, please record:

Date Purchased_______________________________
Where Purchased__________________________________________
Date Installed____________/____________Month/Year

Replacement date is five years after installation: /

BRK Electronics® is a registered trademark of BRK Brands, Inc. First Alert® is a registered trademark of the First Alert Trust.

Printed in Mexico M08-0094-006 K1 08/08

Month/Year

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the First Alert UL217

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the First Alert UL217

Be the first to ask — other owners or our team will answer.

Original document

First Alert UL217 manual PDF

11 pages·749 KB·Carbon Monoxide Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…