SMOKE & CO COMBO ALARM P H O T O E L E C T R I C


First Alert Model SCO5 is a battery operated single station photoelectric smoke and carbon monoxide combination alarm specifically designed for residential and institutional applications including sleeping rooms of hospitals, hotels, motels, dormitories, and other multifamily dwellings as defined in standard NFPA 101. Model SCO5 has been fully tested and complies with, UL217, UL2034, CSFM, NFPA 72, and NFPA 101 and other agencies that model their codes after the above agencies. It meets building codes where battery operated photoelectric smoke and carbon monoxide combination alarms are required and with model building codes published by the ICC.
ELECTROCHEMICAL CO SENSOR Most accurate technology available for detecting carbon monoxide as compared to other sensing technologies.
First Alert Model SCO5 is a state of the art smoke and CO combination alarm designed to provide early warning of a fire or carbon monoxide danger. It features a photoelectric smoke sensing chamber and an electrochemical CO sensor. It features a Sweeping Horn Tone that has a lower and varying frequency that makes it easier for the elderly with normal age related hearing loss to hear the horn. Two AA alkaline batteries power supply, a single button test/silence switch. This alarm has two silence features. Low Battery Silence: Temporarily silence the low battery chirp for up to eight hours. Alarm Silence: Silence alarm for several minutes. Optipath 360 technologyTM provides 360 degrees of direct access to the smoke sensing chamber. It also features tamper resistant locking pins that lock the alarm to the mounting bracket and/or the battery drawer to prevent removal of battery. Battery installation and removal can occur while the unit is mounted to the ceiling or wall via the slide out battery drawer. Designed for wall or ceiling mounting. Includes mounting anchors and screws.
TM Provides 360 degrees of direct access to the smoke sensing chambers.
SWEEPING HORN TONE Varying horn tone makes it easier for elderly with normal age related hearing loss to hear the alarm.
TWO SILENCE FEATURES Silences low battery chirp for up to eight hours or silence nuisance alarm for several minutes.

TWO LOCKING FEATURES Pins are provided to lock battery drawer and/or alarm to base. Perfect for apartment, dormitory or hotel applications.

Alarm Dimensions: 5.0” dia x 2.0”H Weight: 8.4 oz. Operating Voltage: 2AA Alkaline Battery Powered Temperature Range: 40F (4C) to 100F (38C) Humidity Range: 10% to 95% relative humidity (RH) Audio Alarm: 85dB at 10 feet Test/Silence: Electronically simulates smoke and CO conditions, causing the unit to alarm and temporarily silence the alarm Remote: Use vol/chn buttons on most household IR remotes. Manual: Press and hold test/silence button

TOP VIEW SIDE VIEW
BRACKET

Alarm Reset: Automatic when smoke and/or CO clears Smoke Sensor: Photoelectric CO Sensor: Electrochemical Indicator Lights/Sounds: DC Power: Intermittent Red Light Alarm: Audio Alarm, rapidly flashing red light by corresponding smoke or CO indicator light
The smoke/CO combination alarm shall be a First Alert Model SCO5 and shall provide at a minimum the following features and functions: 1. A Photoelectric smoke sensing chamber and an electrochemical CO sensor. 2. The unit shall have a lower and varying horn frequency to to make it easier for the elderly with normal age related hearing loss to better hear the horn 3. The unit shall be capable of self restoring. 4. Fully screened smoke sensing chamber to resist entry of small insects thereby reducing the probability of unwanted alarms. 5. Powered by supervised 2 AA alkaline batteries and a solid state piezo horn rated at 85dB at 10 ft. 6. A visual green LED power-on indicator to confirm unit is receiving power. A visual red indicator to show unit is alarm. 7. A full function test button should check all alarm functions by simulating a smoke and CO condition, causing the unit to alarm. 8. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8 hours. Alarm Silence: Temporarily silence unwanted nuisance alarms. 9. Optipath 360 TechnologyTM - provides 360 degrees of direct access to the smoke sensing chambers. 10. Two Locking features - tamper resistant locking pins that lock battery drawer and/or alarm to mounting bracket. 11. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 95%. 12. The unit shall contain mounting hardware and shall be listed for wall or ceiling mounting. 13. The unit shall at a minimum meet the requirements of UL217, UL2034, CSFM, NFPA 72, NFPA 720, NFPA 101, ICC
Individual Carton Dimensions 5.13 ”L x 2.380”W x 5.13”H
Weight 0.66lbs.
Cube 0.036 ft3
Master Carton Dimensions 10.750”L x 7.880”W x 11.06”H
Weight 8.4lbs.
Cube 0.542 ft3
Cases per Layer 22
Number of Layers 4
Cases per Pallet 88
Units per Pallet 1,056
Cube 53.9 ft3
Installation of this alarm must conform to NFPA 72 and NFPA 720. Always check your local building codes. Follow all instructions for placement as outlined in the user’s manual.
Weight 804 lbs.


Close Door. Insert Pin in Holes through alarm and Battery Drawer
©2009 BRK Brands, Inc. a Jarden Corporation Company (NYSE: JAH) 3901 Liberty Street Road Aurora, IL 60504-8122 All rights reserved First Alert is a registered trademark of the First Alert Trust BRK is a registered trademark of BRK Brands, Inc. CM2912
Master Pack 12 · Pallet Information
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.