First Alert CO600

6 pages·2.3 MB·Carbon Monoxide Alarm·PDF·ENDEFRITNLJA
First Alert CO600
Table of Contents 38 sections INTRODUCTION · BASIC SAFETY INFORMATION · TABLE OF CONTENTS · HOW YOUR CO ALARM WORKS · … ShowHide
Page 2 of the First Alert CO600 user manual — INSTALLATION
Page 2 · click to enlarge
Page 2

UNDERSTANDING YOUR CO ALARM

WHERE CO ALARMS SHOULD NOT BE INSTALLED

WHAT YOU SEE AND HEAR DURING INSTALLATION

WHEN YOU FIRST PLUG-IN THE CO ALARM:

DO NOT LOCATE THIS CO ALARM: • In garages, kitchens, furnace rooms, or in any extremely dusty, dirty or greasy areas.

HORNSilent POWER/ALARM LIGHT: Shines continuously
  • Closer than 15 feet (4.6 meters) from a furnace or other fuel burning heat source, or fuel burning appliances like a water heater.

UNDER NORMAL CONDITIONS (AC POWER):

HORNSilent POWER/ALARM LIGHT: Shines continuously
  • Within 5 feet (1.5 meters) of any cooking appliance.
  • In extremely humid areas. This Alarm should be at least 10 feet (3 meters) from a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room or other source of high humidity.

WHEN YOU TEST THE CO ALARM:

HORNSounds loudly - 4 beeps, pause, 4 beeps, pause POWER/ALARM LIGHT: Flashes rapidly
  • In areas where temperature is colder than 40˚ F (4˚ C) or hotter than 100˚ F (38˚ C). These areas include non-airconditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches, and garages.

WHAT YOU SEE AND HEAR UNDER DIFFERENT CONDITIONS:

WHEN THE ELECTRICITY COMES BACK ON AFTER A POWER FAILURE:

  • In turbulent air, like near ceiling fans, heat vents, air conditioners, fresh air returns, or open windows. Blowing air may prevent CO from reaching the sensors.

HORN: Silent POWER/ALARM LIGHT: Shines continuously.

  • In direct sunlight.
  • In outlets covered by curtains or other obstruction.

IF THE CO ALARM IS NOT OPERATING PROPERLY (MALFUNCTION SIGNAL):

HORN: Three rapid chirps every minute POWER/ALARM LIGHT: Flashes three times in sync with the horn.

  • This CO Alarm is designed for use inside a single-family home or apartment. It is not meant to be used in common lobbies, hallways, or basements of multi-family buildings unless working CO Alarms are also installed in each family living unit. CO Alarms in common areas may not be heard from inside individual family living units.

WHAT YOU SEE AND HEAR IF CO IS DETECTED:

ALARM LEVELS OF CO ARE DETECTED:

  • This CO Alarm alone is not a suitable substitute for complete detection systems in places which house many people, like hotels or dormitories, unless a CO Alarm is also placed in each unit.

HORN: Sounds loudly - 4 beeps, pause, 4 beeps, pause. This sequence repeats for as long as the unit is in alarm. POWER/ALARM LIGHT: Flashes rapidly

IF YOU SILENCE THE ALARM:

  • DO NOT use this CO Alarm in warehouses, industrial or commercial buildings, special-purpose non-residential buildings, or airplanes. This CO Alarm is specifically designed for residential use, and may not provide adequate protection in non-residential applications.

HORN: Silent for about 4 minutes POWER/ALARM LIGHT: Flashes rapidly Note: After 4 minutes, if CO levels drop below alarm levels, the unit will remain silent and return to normal operation. If CO presence still indicates a potentially dangerous situation, the horn will sound again.

IF THE CO LEVELS RETURN TO NORMAL:

HORNSilent POWER/ALARM LIGHT: Shines continuously

INSTALLATION

WHERE TO INSTALL CO ALARMS The National Fire Protection Association (NFPA) recommends that a CO Alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms. For added protection, install additional CO Alarms in each separate bedroom, and on every level of your home.

In a Single-level Home: • Install at least one CO Alarm near or within each separate sleeping area.

  • For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.

If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm at BOTH ends of the hallway.

In a Multi-level Home: • Install at least one CO Alarm near or within each separate sleeping area.

First Alert CO600 — INSTALLATION diagram (page 2)
Fig. 1
  • For added protection, install at least one CO Alarm on each level of the home.
  • For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
BEDROOMBEDROOM HALLKITCHEN

This unit should receive continuous electrical power. Choose an outlet where it cannot be accidentally unplugged or switched off by children. Keep small children away from the unit. Teach them not to play with it or unplug it. Explain what the alarms mean.

Page 3 of the First Alert CO600 user manual — If you hear the alarm horn and the red light is flashing,
Page 3 · click to enlarge
Page 3

HOW TO INSTALL YOUR CO ALARM

USING THE SILENCE FEATURE

Read “Where To Install Your CO Alarm” before starting.

Before you start installation, find the pair of self-adhesive labels included with this CO Alarm. On each label write in the phone number of your emergency responder (like 911) and a qualified appliance tech- nician. Place one label near the CO Alarm, and the other label in the “fresh air” location you plan to go if the alarm sounds.

The Silence Feature is for your convenience only and will not correct a CO problem. Always check your home for a potential problem after any alarm. Failure to do so can result in injury or death.

1. Plug the unit into a standard UNSWITCHED 120V AC outlet. The unit should be located where it can wake you if it alarms at night.

NEVER unplug your CO Alarm to silence the horn. Use the silence feature. Unplugging the CO Alarm removes your protection! See “If Your CO Alarm Sounds” for details on responding to an alarm.

When CO reaches alarm levels the alarm will sound— repeating horn pattern: 4 beeps, a pause, 4 beeps, etc. Press and hold the Test/Silence button until the horn is silent. The initial Silence cycle will last approxi- mately 4 minutes.

2. Make sure the POWER/ALARM light shines continuously when you plug it.
3. Test by pressing the Test/Silence button firmly until the unit sounds: four loud beeps, pause, 4 beeps. During testing, the POWER/ ALARM light will flash rapidly. This is normal.

While the detector is silenced:

IF YOUR CO ALARM SOUNDS

If the CO Alarm...

This means...

Is silent for only 4 minutes, then starts sounding loudly— 4 beeps, pause, 4 beeps, pause

CO levels are still potentially dangerous.

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!

IF THE ALARM SIGNAL SOUNDS: 1. Operate the Test/Silence button.

If the CO Alarm...

This means...

Remains silent after you pressed the Test/Silence button

CO levels are dropping.

2. Call your emergency services, fire department or 911. Write down the number of your local emergency service here:
3. Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.

TESTING AND MAINTENANCE

WEEKLY TESTING

Press the Test/Silence button on the Alarm cover until alarm sounds. During testing, you will hear a loud alarm sequence – 4 beeps, pause, 4 beeps, pause. The alarm sequence should last 5-6 seconds. If it does not alarm, make sure the unit is fully plugged into an unswitched outlet. If the unit still does not alarm, replace it immediately.

4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:

  • If the Alarm ever fails to test properly, replace it immediately. Products under warranty may be returned to the manufacturer for replacement. See “Limited Warranty” at the end of this manual.
  • DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.
  • NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.
First Alert CO600 — WEEKLY TESTING diagram (page 3)
Fig. 2

If you hear the alarm horn and the red light is flashing,

REGULAR MAINTENANCE

  • To keep the CO Alarm working properly:
  • Test it every week as described in “Weekly Testing.”
  • Vacuum the CO Alarm cover at least once a month, using the soft brush attachment. Never use water, cleaners, or solvents, since they may damage the unit. Test the Alarm again after vacuuming.

Alarms have various limitations. See "General Limitations of CO Alarms" for details.

DO NOT spray cleaning chemicals or insect sprays directly on or near the CO Alarm. DO NOT paint over the CO Alarm. Doing so may cause permanent damage.

  • Household cleaners, aerosol chemicals and other contaminants can affect the sensor. When using any of these materials near the CO Alarm, make sure the room is well ventilated.
  • If your home is being fumigated, unplug the unit temporarily and put it where it will not be exposed to chemicals or fumes. When fumigation is complete and all traces of fumes clear, plug the unit back in and retest it.

AC Plug

Page 4 of the First Alert CO600 user manual — FINDING THE SOURCE OF CO AFTER AN ALARM
Page 4 · click to enlarge
Page 4

WHAT YOU NEED TO KNOW ABOUT CO

WHAT IS CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO.

POTENTIAL SOURCES OF CO IN THE HOME

First Alert CO600 — POTENTIAL SOURCES OF CO IN THE HOME diagram (page 4)
Fig. 3

These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane.

Common appliances are often sources of CO. If they are not properly maintained, are improperly ventilated, or malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient. “Air-tight” homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.

SYMPTOMS OF CO POISONING

These symptoms are related to CO POISONING and should be discussed with ALL household members.

Mild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).

Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate.

Extreme Exposure: Convulsions, unconsciousness, heart and lung failure. Exposure to carbon monoxide can cause brain damage, death.

Fuel-burning appliances like: portable heater, gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer.

Damaged or insufficient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked or clogged chimney opening.

Some individuals are more sensitive to CO than others, including people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. Members of sensitive populations should consult their doctors for advice on taking additional precautions.

Improper use of appliance/device: operating a barbecue grill or vehicle in an enclosed area (like a garage or screened porch).

Transient CO Problems: “transient” or on-again-off-again CO problems can be caused by outdoor conditions and other special circumstances.

FINDING THE SOURCE OF CO AFTER AN ALARM

Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of CO after an alarm. These are a few of the factors that can make it difficult to locate sources of CO:

The following conditions can result in transient CO situations:

1. Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
  • House well ventilated before the investigator arrives.
  • Problem caused by “backdrafting.”
  • Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air with extended periods between cycles).
  • Transient CO problem caused by special circumstances.

Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO. BRK Brands, Inc. shall not be obli- gated to pay for any carbon monoxide investigation or service call.

  • Negative pressure differential resulting from the use of exhaust fans.
  • Several appliances running at the same time competing for limited fresh air.

HOW CAN I PROTECT MY FAMILY? A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threaten- ing for average, healthy adults.

  • Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
  • Obstructions in or unconventional vent pipe designs which can amplify the above situations.

A CO Alarm is not a substitute for proper maintenance of home appliances.

2. Extended operation of unvented fuel burning devices (range, oven, fireplace).

To help prevent CO problems and reduce the risk of CO poisoning:

3. Temperature inversions, which can trap exhaust close to the ground.
  • Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow. Also, have a professional check for rust and corrosion, cracks, or separations. These conditions can prevent proper air movement and cause backdrafting. Never “cap” or cover a chimney in any way that would block air flow.
4. Car idling in an open or closed attached garage, or near a home.

These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come and go, they are also hard to recreate during a CO investigation.

  • Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC companies offer appliance inspections for a nominal fee.
  • Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust and scaling. Also check the flame on the burner and pilot lights. The flame should be blue. A yellow flame means fuel is not being burned completely and CO may be present. Keep the blower door on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are vented to the outside. Do not grill or barbecue indoors, or in garages or on screen porches.
  • Check for exhaust backflow from CO sources. Check the draft hood on an operating furnace for a backdraft. Look for cracks on furnace heat exchangers.
  • Check the house or garage on the other side of shared wall.
  • Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a window or a door. Opening windows and doors can significantly decrease CO levels.

In addition, familiarize yourself with all enclosed materials. Read this manual in its entirety, and make sure you understand what to do if your CO Alarm sounds.

Page 5 of the First Alert CO600 user manual — GENERAL LIMITATIONS OF CO ALARMS
Page 5 · click to enlarge
Page 5

REGULATORY INFORMATION FOR CO ALARMS

WHAT LEVELS OF CO CAUSE AN ALARM? Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to levels of CO and exposure times as described below. CO levels are measured in parts per million (ppm) of CO over time (in minutes).

Why is this important? Because you need to be warned of a potential CO problem while you can still react in time. In many reported cases of CO exposure, victims may be aware that they are not feeling well, but become disoriented and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!

UL2034 Required Alarm Points*: • If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES

  • If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.

Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034.

  • If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.

* Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH). The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.

According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and is designed to alarm before CO levels become life threatening. This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained as described in this manual.

CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume it’s not present. • An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.

  • An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours.

Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.

This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults.

Audible Alarm: 85 dB minimum at 10 feet (3 meters).

GENERAL LIMITATIONS OF CO ALARMS

This CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide detectors must be met.

CO Alarms may not be heard. The alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if the CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This CO Alarm is not intended for people who are hearing impaired.

CO alarms may not waken all individuals. If children or others do not readily waken to the sound of the CO alarm, or if there are infants or family members with mobility limitations, make sure that someone is assigned to assist them in the event of an emergency.

CO Alarms will not work without power. This CO Alarm requires a continuous supply of AC power. Plug into an unswitched 120V AC outlet only.

CO Alarms are not a substitute for a smoke alarm. Although fire is a source of carbon monoxide, this CO Alarm does not sense smoke or fire. This CO Alarm senses CO that may be escaping unnoticed from malfunctioning furnaces, appliances, or other sources. Early warning of fire requires the installation of smoke alarms.

CO Alarms for Solar or Wind Energy users and battery backup power systems: AC powered CO Alarms should only be operated with true or pure sine wave inverters. Operating this CO Alarm with most battery-powered UPS (uninterruptible power supply) products or square wave or “quasi sine wave” inverters will damage the Alarm. If you are not sure about your inverter or UPS type, please consult with the manu- facturer to verify.

CO Alarms are not a substitute for life insurance. Though these CO Alarms warn against increasing CO levels, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives from CO poisoning. Homeowners and renters must still insure their lives.

This CO Alarm will not sense carbon monoxide that does not reach the sensor. This CO Alarm will only sense CO at the sensor. CO may be present in other areas. Doors or other obstructions may affect the rate at which CO reaches the CO Alarm. For this reason, if bedroom doors are usually closed at night, we recommend you install a CO Alarm in each bedroom and in the hallway between them.

CO Alarms have a limited life. Although the CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test your CO Alarm weekly.

CO Alarms are not foolproof. Like all other electronic devices, CO Alarms have limitations. They can only detect CO that reaches their sensors. They may not give early warning to rising CO levels if the CO is coming from a remote part of the home, away from the CO Alarm.

CO Alarms may not sense CO on another level of the home. For example, a CO Alarm on the second level, near the bedrooms, may not sense CO in the basement. For this reason, one CO Alarm may not give adequate warning. Complete coverage is recommended. Place CO Alarms on each level of the home.

Page 6 of the First Alert CO600 user manual — Date Installed: ____________/____________Month/Year
Page 6 · click to enlarge
Page 6
TROUBLESHOOTING GUIDE PROBLEM...THIS MEANS...YOU SHOULD... Red light is OFF. Unit will not alarm when you press the Test/Silence button.CO Alarms may not be plugged all the way in, or is not receiving power.Gently push unit all the way into outlet. Make sure it is not plugged into an outlet controlled by a switch. The light flashes (RED) and the horn sounds 3 quick “chirps” every minute.MALFUNCTION SIGNAL. CO Alarm needs to be replaced.Make sure unit is plugged in securely. CO Alarms under warranty should be returned to manufacturer for replacement. See “Limited Warranty” for details. CO Alarm goes back into alarm 4 minutes after you press the Test/Silence button.CO levels indicate a potentially dangerous situation.IF YOU ARE FEELING SYMPTOMS OF CO POISONING, EVACUATE your home and call 911 or the Fire Department. If not, press the Test/ Silence button again and keep ventilating your home. CO Alarm sounds frequently even though no high levels of CO are revealed in an investigation.The CO Alarm may be improperly located. Refer to “Where to Install CO Alarms.”Relocate your Alarm. If frequent alarms continue, have home rechecked for potential CO problems. You may be experiencing an intermittent CO problem.

If you have any questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005.

LIMITED WARRANTY

BRK Brands, Inc. ("BRK") the maker of First Alert® brand products, warrants that for a period of 5 years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value This is your exclusive warranty.

This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change the terms and conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty does not cover acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces, or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state, or province to province.

How to Obtain Warranty Service

Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005, 7:30 AM to 5:00 PM, Central Standard Time, Monday through Friday. To assist in serving you, please have the model number and date of purchase available when calling. For Warranty Service return to: BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906

For your records, please record:

Replacement date is five years after installation:

Date Purchased: __________________

_____________/____________Month/Year

Where Purchased: _______________________

Date Installed: / Month/Year

First Alert® is a registered trademark of the First Alert Trust.

Printed in Mexico M08-0152-002 S 07/07

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the First Alert CO600

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the First Alert CO600

Be the first to ask — other owners or our team will answer.

Original document

First Alert CO600 manual PDF

6 pages·2.3 MB·Carbon Monoxide Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…