8214/8514/07187 Respirator N95 Particulate

3M recommended for welding on stainless steel, aluminum, galvanized steel, and other applications where ozone and nuisance organic vapors* may be present.

User Instructions

(Keep insert for reference)

Distributed by:

TM

.com

(888) 933-0100

Page 2 of the Filtera 8514 user manual — 8214/8514/07187 Respirator N95 Particulate
Page 2 · click to enlarge
Page 2

07187 is a catalog number only. NIOSH approved as 3M™ 8214 N95 Particulate Respirator.

* 3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government occupational exposure limits, whichever is lower (not NIOSH approved for use against ozone). 3M recommended for relief against nuisance levels of organic vapors. (Nuisance level organic vapor refers to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits, whichever is lower.)

Filtera 8514 — 8214/8514/07187 Respirator N95 Particulate diagram (page 2)
Fig. 1 · 8214/8514/07187 Respirator N95 Particulate

This respirator helps protect against certain airborne contaminants. Misuse may result in sickness or death. For proper use, see supervisor, or User Instructions, or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at 1-800-267-4414.

Use For: Solids such as those from processing minerals, coal, iron ore, flour, and certain other substances. Liquid or non-oil based particles from sprays that do not also emit oil aerosols or harmful vapors. Metal fumes produced from welding, brazing, cutting and other operations involving heating of metals. Organic vapors below the OSHA PEL or applicable government standards, whichever is lower. 3M recommended for ozone protection up to 10 times the OSHA PEL (not NIOSH approved for use against ozone).

Do Not Use For: Gases, oil aerosols, asbestos or sandblasting. Aerosol and/or ozone concentrations that exceed 10 times the PEL, specific OSHA standards, or applicable government regulations, whichever is lower. Organic vapors, including those present in paint spraying operations, when concentrations exceed the OSHA PEL or applicable government occupational exposure limits, whichever is lower. This respirator does not supply oxygen.

Use Instructions: 1. Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can reduce respirator effectiveness and may result in sickness or death.

2. Before occupational use of this respirator a written respiratory protection program must be implemented meeting all the requirements of OSHA 29 CFR 1910.134 such as training and fit testing and applicable OSHA substance specific standards. In Canada, CSA standard Z94.4-93 requirements must be met.
3. The particles which can be dangerous to your health include those so small you cannot see them.
4. Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress occurs.
5. Store the respirator away from contaminated areas when not in use.
6. Dispose of used product in accordance with applicable regulations.
Page 3 of the Filtera 8514 user manual — 8214/8514/07187 Respirator N95 Particulate
Page 3 · click to enlarge
Page 3

Use Limitations: 1. This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.

2. Do not use when concentrations of contaminants are immediately dangerous to life and health, are unknown or when concentrations exceed 10 times the permissible exposure limit (PEL) or according to specific OSHA standards or applicable government regulations, whichever is lower.
3. Do not alter, abuse or misuse this respirator.
4. Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator.

Time Use Limitations: 1. If respirator becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area immediately and replace the respirator.

2. If used for ozone protection, replace respirator in accordance with an established change schedule, or earlier if smell, taste or irritation from contaminants is detected.

Fitting Instructions: Must be followed each time respirator is worn.

1. Thread the top elastic strap through the top buckle. Repeat for the bottom elastic strap. Place the bottom elastic strap around the head, just below the ears. Untwist the strap.
Filtera 8514 — 8214/8514/07187 Respirator N95 Particulate diagram (page 3)
Fig. 2 · 8214/8514/07187 Respirator N95 Particulate

Diagram 1

Page 4 of the Filtera 8514 user manual — 8214/8514/07187 Respirator N95 Particulate
Page 4 · click to enlarge
Page 4
2. Pull the top strap over your head, resting it above the ears at the top back of your head. Untwist the strap.
Filtera 8514 — 8214/8514/07187 Respirator N95 Particulate diagram (page 4)
Fig. 3 · 8214/8514/07187 Respirator N95 Particulate
3. Adjust the strap tension by pulling the straps as shown (3a). Strap tension may be decreased without removing respirator from the head by pushing out on the back of the buckle (3b).
Filtera 8514 — 8214/8514/07187 Respirator N95 Particulate diagram (page 4)
Fig. 4 · 8214/8514/07187 Respirator N95 Particulate
Filtera 8514 — 8214/8514/07187 Respirator N95 Particulate diagram (page 4)
Fig. 5 · 8214/8514/07187 Respirator N95 Particulate

Diagram 3a Diagram 3b

4. Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose area to the shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece.

Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance. Use two hands.

Filtera 8514 — 8214/8514/07187 Respirator N95 Particulate diagram (page 4)
Fig. 6 · 8214/8514/07187 Respirator N95 Particulate

Diagram 2 · Diagram 4

Page 5 of the Filtera 8514 user manual — REMOVAL INSTRUCTIONS:
Page 5 · click to enlarge
Page 5
5. Perform a User Seal Check prior to each wearing. To check the respirator-to-face seal, cover the front of the respirator completely with both hands, being careful not to disturb the position of the respirator. Inhale sharply. A negative pressure should be felt inside the respirator. If any leakage is detected, readjust the position of the respirator according to Steps #3 and #4.

If you CANNOT achieve a proper seal DO NOT enter the contaminated area. See your supervisor.

Filtera 8514 — REMOVAL INSTRUCTIONS: diagram (page 5)
Fig. 7

REMOVAL INSTRUCTIONS:

See step 3b of Fitting Instructions and decrease strap tension as described. Cup respirator in hand to maintain position on face and pull bottom strap over head. Still holding respirator in position, pull top strap over head and remove respirator.

Diagram 5

Page 6 of the Filtera 8514 user manual — REMOVAL INSTRUCTIONS:
Page 6 · click to enlarge
Page 6

NIOSH Approved: N95 At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.

Filtera 8514 — REMOVAL INSTRUCTIONS: diagram (page 6)
Fig. 8

This respirator contains no components made from natural rubber latex.

Page 7 of the Filtera 8514 user manual — TM
Page 7 · click to enlarge
Page 7

FOR MORE INFORMATION and assistance on 3M occupational health and environmental safety products, contact your local 3M representative or call 3M OH&ESD Technical Service toll free in U.S.A., 1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.

Exported by/Exporté par/ Exportado por3M Occupational Health and Environmental Safety Division

3M Center, Building 235-2W-70 P.O. Box 33010 St. Paul, MN 55133-3010 Assembled in U.S.A. from U.S.A. and imported components.

©3M 2001 38-9017-4804-6

Distributed by:

TM

.com

(888) 933-0100

Ask about the Filtera 8514

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Filtera 8514

Be the first to ask — other owners or our team will answer.

Original document

Filtera 8514 manual PDF

7 pages·173 KB·Oxygen Equipment·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…