Instruction/ maintenance manual of the product ASDA-A2 888 Digital
Go to page of 37
.
English-1 Preface This quick start will be hel pful in the installation, wiring, inspection, and operation of Delta ASDA-A2 serie s AC servo drive and EC MA series ser vo motor . Before using the pro duct, please read thi s quick start to ensure correct use.
English - 2 Wiring ¾ Connect the gr ound ter minals to a class-3 ground (Gr oun d r esistance should no t exceed 100 ). Impr oper gr ounding m ay r esult in electric sho ck or fir e. ¾ Do not connect any po wer supplies to the U, V , W terminals.
English-3 Main Circui t T erminal Wiring ¾ Please perform the wir ing after the terminal b locks ar e all r emoved from the drive. ¾ Insert only one wire into one terminal on the terminal bl ock. ¾ When inserting wires, please ensur e that the conductors ar e not shorted to adjac ent terminals or wires.
English - 4 Encoder Cable - W ire Gauge mm 2 (A W G) Servo Drive Wire Size Core Number UL Rating S tandard W ire Lengt h ASD-A2-0221- 0.13 (A W G26) 10 core (4 pair) UL2464 3m (9.84ft.) ASD-A2-0421- 0.13 (A W G26) 10 core (4 pair) UL2464 3m (9.
English-5 Minimum Clearances: Install a fan to increase ventilation to avoid ambie nt temperatures that exceed the s pecification. W hen installing one or more drives a djacent to each oth er please follo w the clearances as sh own in the following di agram.
English - 6 NOTE The scale o f the clearances d oes not match t he dimensions as show n in the draw ing above. In the event of any di screpancy betw een t he clearances and the dimensions, t he dimensions shall prevai l.
English-7 Basic Inspection After power in connected to t he AC ser vo drive, the char ge LED will be lit which indicates that the AC ser vo drive is ready . Item Content General Inspection Periodically inspect t he screws of the ser vo drive, motor sha ft, terminal block and the connection to m echanical s ystem.
English - 8 Wiring Methods Single-Phase Po wer Supply Connection ( For 1kW and belo w models).
English-9 Three-Phase Po wer Supply Connection ( For all models).
English - 10 Basic Wiring 400W and below models (without built -in regenerative res istor).
English-1 1 750W and abo ve models (with built-in regenerative resist or and fan).
English - 12 Servo Drive Dimensions A B C D E Weight 200W ~ 400W 173 (6.81) 170 (6.69) 45 (1.77) 27.5 (1.08) 163 (6.42) 1.5 (3.3) 750W ~ 1.5kW 173 (6.81) 180 (7.09) 65 (2.56) 47 (1.83) 163 (6.42) 2.0 (4.4) 2kW ~ 3kW 216 (8.50) 203 (7.99) 82 (3.23) 62 (2.
խ - 1 Ԕ֏ ტ൞ࠌشءข Δ ڼٝڜᇘ֫ם༼ࠎ ASDA-A2 ߓ٨ۻࣚ ᦀ೯ᕴ֗ ECMA ߓ٨ۻ್ࣚሒऱઌᣂ ᇷಛ Ζ ڇࠌشհছ Δ ᓮ൞גาᇡᦰءڜᇘ֫ םאᒔঅࠌشՂऱإᒔ .
խ - 2 ᏹբݙཀ ¾ ᐒఓഢ໒ۈၮᙯǴଛӝځ٬ҔޣୖኧፓۓॶǶ ऩ҂ፓډ࣬಄ޑ҅ዴ ۓॶǴёૈᏤठ ᐒఓഢၮᙯѨѐڋ܈ว ғࡺምǶ ¾ ᐒᏔ.
խ - 3 Ҩڇᜭજጡᄃ྿፟ЩჍ၆ᑕણܑ ۻࣚᦀ೯ᕴ ኙᚨऱۻ್ࣚሒ 200W ASD-A2-0221- ECMA-C10602 S ΰ S=14mm α 400W ASD-A2-0421- ECMA-C10604 S ΰ S=14mm α .
խ - 4 ᒳᒘᕴᒵ — ᒵஉ mm² ΰ AWG α ᦀ೯ᕴীᇆ ज़ᒵ֡՚ ज़ᒵයᑇ ᒵጟᒤ ᑑᄷᒵ९ ASD-A2-0221- 0.13 ΰ AWG26 α 10 යΰ 4 ኙα UL2464 3 ֆ֡ΰ 9.84 ܢα ASD-A2-0421- 0.13 ΰ AWG26 α 10 යΰ 4 ኙα UL2464 3 ֆ֡ΰ 9.
խ - 5 ڜᇘقრቹΚ Աࠌཋᑷଅ౨ ജڶֺለ܅ऱଅॴאڶயඈ נᑷၦ Δ ᓮࠌشृᙅښԫ ፖڍٌੌۻࣚᦀ೯ ᕴऱڜᇘ ၴሶ၏ᠦ৬ᤜଖΰ ڕՀቹࢬقα Ζ NOTE ڜ.
խ - 6 NOTE ڜᇘቹᚾհၴሶ၏ᠦ ፖ֮ڗုᇞॺֺࠏ ֡՚Δᓮא֮ڗုᇞ ᄷΖ.
խ - 7 ૄώᑭീ ᛀྒྷႈؾ ᛀྒྷփ୲ ԫᛀྒྷ ࡳཚᛀۻࣚᦀ೯ ᕴڜᇘຝٝΕ್ሒၗ֨ፖᖲ ඳຑ൷ऱᝅΕጤ ፖᖲ ඳຝٝऱᝅਢܡ ڶᠾ೯Ζ ൳.
խ - 8 ੨ቢ ઌሽᄭ൷ᒵऄΰ 1.5kW ΰܶαאՀᔞ شα.
խ - 9 Կઌሽᄭ൷ᒵऄΰ ٤ߓ٨ઃᔞشα.
խ - 10 Ҩڇրૄώ͞ဦ 400W Ğӣğͽ˭፟Ğ̰ޙаϠ ܡğ.
խ - 11 750W Ğӣğͽ˯፟Ğ̰ޙ֘ ܡࢲैğ.
խ - 12 ᜭજጡ͎̇ᄃࢦณ A B C D E ૹၦ 200W ~ 400W 173 ΰ 6.81 α 170 ΰ 6.69 α 45 ΰ 1.77 α 27.5 ΰ 1.08 α 163 ΰ 6.42 α 1.5 ΰ 3.3 α 750W ~ 1.5kW 173 ΰ 6.81 α 180 ΰ 7.09 α 65 ΰ 2.56 α 47 ΰ 1.83 α 163 ΰ 6.42 α 2.0 ΰ 4.4 α 2kW ~ 3kW 216 ΰ 8.
ᖎ̚ - 1 ᑣ㿔 ᛳ䇶ᙼՓ⫼ᴀѻક ˈ ℸӑᅝ㺙ݞᦤկ ASDA-A2 ㋏߫ Ԏ᳡偅ࡼ఼ঞ ECMA ㋏߫Ԏ᳡⬉ᴎⱘ Ⳍֵ݇ᙃDŽ Փ⫼Пࠡˈ 䇋ᙼҨ㒚䆺䇏ᴀᅝ㺙 ݞҹ⹂ֱՓ⫼Ϟⱘ.
ᖎ̚ - 2 ᪡⊼ᛣ ¾ ᔧᴎẄ䆒ᓔྟ䖤 䕀ࠡˈ乏䜡 ড়݊Փ⫼㗙খ᭄䇗ᭈ䆒ᅮ ؐDŽ㢹䇗 ᭈࠄⳌヺⱘℷ⹂䆒 ᅮؐˈৃ㛑Ӯᇐ㟈 ᴎẄ䆒䖤䕀༅এࠊথ ⫳.
ᖎ̚ - 3 Ԏ᳡偅ࡼ఼Ϣ⬉ᴎᴎ⾡ৡ⿄ᇍᑨখ✻㸼 Ԏ᳡偅ࡼ఼ ᇍᑨⱘԎ᳡⬉ᴎ 200W ASD-A2-0221- ECMA-C10602 S ΰ S=14mm α 400W ASD-A2-0421- ECMA-C10604 S ΰ S=14mm .
ᖎ̚ - 4 㓪ⷕ఼䜡㒓 — 㒓ᕘ mm² ˄ AWG ˅ 偅ࡼ఼ൟো 㢃㒓ሎᇌ 㢃㒓ᴵ᭄ 㒓⾡㾘㣗 ᷛޚ㒓䭓 ASD-A2-0221- 0.13 ˄ AWG26 ˅ 10 ᴵ˄ 4 ᇍ˅ UL2464 3 ݀ሎ˄ 9.84 㣅 ֡ ˅ ASD-A2-0421- 0.13 ˄ AWG26 ˅ 10 ᴵ˄ 4 ᇍ˅ UL2464 3 ݀ሎ˄ 9.
ᖎ̚ - 5 ᅝ㺙⼎ᛣ˖ ЎњՓᬷ⛁亢㛑 ᳝↨䕗Ԣⱘ亢䰏ҹ᳝ᬜᥦ ߎ⛁䞣ˈ 䇋Փ⫼㗙䙉 ᅜϔৄϢৄѸ⌕Ԏ᳡偅 ࡼ఼ⱘᅝ㺙 䯈䱨䎱⾏ᓎ䆂ؐ˄ བϟ᠔⼎˅ DŽ .
ᖎ̚ - 6 NOTE ᅝ㺙ḷП䯈䱨䎱⾏ Ϣ᭛ᄫ⊼㾷䴲ㄝ↨՟ ሎᇌˈ䇋ҹ᭛ᄫ⊼㾷 ЎޚDŽ !.
ᖎ̚ - 7 ᴀẔ⌟ Ẕ⌟乍Ⳃ Ẕ⌟ݙᆍ ϔ㠀Ẕ⌟ ᅮᳳẔᶹԎ᳡偅ࡼ ఼ᅝ㺙䚼ߚǃ⬉ᴎ䕈ᖗϢᴎ Ẅ䖲໘ⱘ㶎ϱǃッᄤϢ ᴎẄ䚼 ߚⱘ㶎ϱᰃ৺᳝ᵒ ࡼDŽ .
ᖎ̚ - 8 䜡㒓 ऩⳌ⬉⑤㒓⊩˄ 1kW ˄˅ҹϟ 䗖⫼˅.
ᖎ̚ - 9 ϝⳌ⬉⑤㒓⊩˄ ܼ㋏߫ⱚ䗖⫼˅.
ᖎ̚ - 10 Ԏ᳡㋏㒳ᴀᮍഫ 400W ˄˅ҹϟᴎ⾡˄᮴ݙᓎಲ⫳ ⬉䰏˅.
ᖎ̚ - 11 750W ˄˅ҹϞᴎ⾡˄ݙᓎࠢ䔺⬉ 䰏亢˅.
ᖎ̚ - 12 偅ࡼ఼ሎᇌϢ䞡䞣 A B C D E 䞡䞣 200W ~ 400W 173 ΰ 6.81 α 170 ΰ 6.69 α 45 ΰ 1.77 α 27.5 ΰ 1.08 α 163 ΰ 6.42 α 1.5 ΰ 3.3 α 750W ~ 1.5kW 173 ΰ 6.81 α 180 ΰ 7.09 α 65 ΰ 2.56 α 47 ΰ 1.83 α 163 ΰ 6.42 α 2.0 ΰ 4.4 α 2kW ~ 3kW 216 ΰ 8.
An important point after buying a device 888 Digital ASDA-A2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought 888 Digital ASDA-A2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data 888 Digital ASDA-A2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, 888 Digital ASDA-A2 you will learn all the available features of the product, as well as information on its operation. The information that you get 888 Digital ASDA-A2 will certainly help you make a decision on the purchase.
If you already are a holder of 888 Digital ASDA-A2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime 888 Digital ASDA-A2.
However, one of the most important roles played by the user manual is to help in solving problems with 888 Digital ASDA-A2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device 888 Digital ASDA-A2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center