26-Key model · 52-Key model

PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. or its wholly owned subsidiaries ("PSC"). Owners of PSC products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business pur- poses. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting your PSC rep- resentative. Electronic versions may either be downloadable from the PSC website (www.psc.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other PSC publications, please let us know via the “Contact PSC” page.
PSC has taken reasonable measures to provide information in this manual that is complete and accurate, however, PSC reserves the right to change any specification at any time without prior notice.
PSC is a registered trademark of PSC Inc. The PSC logo is a trademark of PSC. All other trademarks and trade names referred to herein are property of their respective owners.
Falcon® is a registered trademark of PSC Inc. and of its wholly owned subsidiaries.
Microsoft Windows®, Windows® 2000, Windows®CE, Windows Mobile® , Windows® NT, and Windows® XP are registered trademarks of Microsoft Corporation.
Disclaimer


with Windows Mobile ®
The Falcon® 4400 series combines the flexibility of Windows Mobile® with the power of the Intel XScale processor, WiFi wireless technology, a large color display, and laser and imaging (1D and 2D) scanning in an ergonomic PDT. The Falcon® 4400 series is designed for warehouses, distribution centers, retail in-store environments, and other inventory management applications requir- ing maximum performance and durability.
Overmolded models will handle 5’ / 1.5M drops to concrete, and have an IP54 environmental rating; and an 86dBA (at 24") / 100dBA (at 10 cm) beeper. The Falcon® 4400 Series will handle demanding data collection tasks in industrial environments.
The Falcon Management Utility (FMU) and Falcon Desktop Utility (FDU) are included on the CD that comes with every unit, providing remote manage- ment and configurability.
This Quick Reference Guide contains the following sections:

Before using the Falcon for the first time, you must install the battery pack into the Falcon, then charge both the battery pack and the backup battery. See Installing the Battery Pack on page 10 for instructions.
You must charge the battery pack and backup battery in a dock or with a power cable prior to your first use of the Falcon. The initial charge time is approximately 24 hours. See Charging the Batteries on page 13 for more information.
System Requirements
Minimum Desktop Computer Requirements
Falcons communicate with the host PC using Microsoft ActiveSync protocol via either a USB port or a serial port. Connect the Falcon to your PC as shown:
Getting Started

Figure 1. Connecting your Falcon to a PC

If you don’t already have ActiveSync (v4.0 or above) on your computer, you can install it from the Getting Started CD included with your device, or download it from the Microsoft website (www.microsoft.com).
When the device is connected to the PC using Activesync, a Desktop Pass-Through (DTPT) connection is established, causing any WiFi connections to be disconnected. To continue to use a WiFi connection while the device is in a cradle that is connected to a PC, disable the “Synchronization” option in Activesync on the Falcon.
Getting Started

Four perspectives of the Falcon® 4400 Series with Windows® Mobile are shown. Refer to Table 1 on page 8 for a list of the illustrated parts with refer- ences to more detailed information.
Figure 2. Falcon Keypad and Connector Views


For a complete description of each key on the Falcon, refer to page 26.
Getting Started

Figure 3. Falcon Scanner and Battery Door Views


Battery Door Latch (2 each)
For more information, please refer to the Falcon® 4400 Windows Mobile® Product Reference Guide (PRG), located on the Falcon 4400 Product CD that came with your device.

Figure 4. Model comparison

Model 4420 Model 4410
Model 4420 with Tethered Stylus
Table 1. Features of the Falcon
Getting Started


Battery Pack
The battery pack in the Falcon is a 3.7 V, Lith- ium Ion battery pack. You will be alerted with a message dialog box when the battery pack reaches a low state.

After charging the first time, a complete charge takes about four (4) hours depending on the bat- tery pack’s state and the recharging method. A sample battery pack label is shown at the right.
You must charge the battery pack and backup battery in a dock or with a power cable prior to your first use of the Falcon. The initial charge time is approximately 24 hours.
If you remove the battery pack or it fails, there is a 30 minute window in which to insert a charged battery pack before the backup battery fails. If your backup bat- tery fails, the contents of the RAM memory will be lost. If your backup battery is less than fully charged, there is a proportionally smaller window of time available to replace the main battery. Usage time will also be reduced.
Always charge the battery pack within the temperature range of 32°–113°F (0°– 45°C).
Use only the authorized power supplies, battery packs, chargers, and docks sup- plied by your PSC reseller. The use of any other power supplies can damage the Falcon and void your warranty. Refer to the PRG for the correct power supplies and Accessories.
Powering the Falcon

Lithium-ion battery packs may get hot, explode, ignite, or/and cause serious injury if exposed to abusive conditions.
In the event the battery leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
PSC recommends annual replacement of rechargeable battery packs to ensure maximum performance.
When you first remove the Falcon from the box, you must charge both the battery pack and the backup battery for a minimum of 24 hours.
Complete the following instructions to install the battery pack:
Powering the Falcon

Figure 5. Installing the Battery Pack
Unhook/hook Strap As Needed
Cover Plate (unit may have Handle here instead)
If you remove the battery pack or the battery fails, you have about 30 minutes to swap in a new battery pack or charge the battery pack before the backup battery fails (if the backup battery has been fully charged).

Battery Status Indicators
Tap the Battery icon at the top of the screen to view the Battery status.
Figure 6. Battery level


Table 2. Battery Status Indicators
Battery Status Icon Description
Battery Full This icon indicates that the battery is fully charged.
Battery Charging This icon indicates that the battery pack is in the process of recharging.
Battery Low This icon indicates that the battery pack is low.
When the battery is totally discharged, the battery sensor initiates a shutdown of all applications, and closes the RF Network connection. If the battery pack has com- pletely discharged, when the battery pack is charged or replaced, the unit will resume as before.

Additionally, the Power control applet displays a battery power gauge. You can check the status of both the Main Battery and the Backup battery. Tap > Settings > System > Power. See the Falcon 4400 with Windows Mobile® Product Reference Guide (PRG) for more information on configuration items.
Figure 7. Battery Power Gauge

There are several methods for charging the battery pack and backup battery. LEDs on the Falcon, the Single-Slot Dock, Four-Slot Dock, and Four-Slot Battery charger give visual indication of the charge state.
The initial charge for a Falcon should be done in a Dock in order to charge the Backup Battery.
Table 3 on page 14 gives an overview of all the LEDs and what they indicate.
Charging the Batteries

Table 3. Battery Charging Methods and Indications

Charging Duration 4-6 hours 4-6 hours 3-5 hours > 3 hours
Dock or Charger Battery Charge LED(s) No effect No effect
Charging the Batteries

There are two models of docks for the Falcon: a Single-Slot dock and a Four- Slot dock. On both models, an external power supply (AC adaptor) provides power to the dock.
There are two methods for charging a battery pack using a Single-Slot dock. Refer to Table 3 on page 14 to view methods of battery pack charging using the dock, charge duration, dock status indicators and their purpose. For more information on the dock, refer to the dock Operating Instructions that come with each dock.
Use only the correct battery chargers and docks with this color Falcon. This tech- nology used for these models is incompatible with other PSC Falcon chargers and docks, including the Falcon 4410/4420 monochrome models.
Figure 8. Charging the Battery Pack in a Single-Slot Dock
Top/Rear View of Single-Slot Dock


Battery Pack in Spare Battery Charging Slot
Battery Pack in Spare Battery Charging Slot
Refer to Table 3 on page 14 for a list of LED indicators and their purpose. Refer to the PRG for more information on storage and disposal of batteries.

The 3V Lithium Backup Battery receives its charge from the Battery Pack. To retain date, time, data, and other settings for the Falcon, maintain at least a minimal charge on the Battery Pack.
To view the status of the Backup battery, tap > Settings > System > Power, then tap the Battery tab to view. See the Falcon 4400 with Windows Mobile® Product Reference Guide (PRG) for more information on configuration items.
Figure 9. Battery Status Display
Charging the Batteries

Setting Up the Mobile Computer
A Four-Slot Battery Charger is available to charge batteries independently from the Falcon. To use, insert the batteries into the slots in the charger, align- ing the battery contacts with those in the Charger.
Figure 10. Four-Slot Battery Charger

Battery discharge characteristics vary from eight to nine and a half (8-9.5) hours, depending upon device usage, number of scans per minute, backlight usage, and other factors that draw upon battery power.
At first use or a Clean Boot, the unit will go through a series of initial bootup sequences. See Touchscreen Calibration on page 18, Entering a Password on page 18, and Radio Card Setup on page 19.
Power Indicator LED

Setting Up the Mobile Computer
Figure 11. Touchscreen Calibration

Follow the on-screen directions to cali- brate the touchscreen.
For more information on touchscreen calibration, refer to the PRG and the Microsoft help on your device.
The first time you use the Falcon you will be prompted to enter a password. Tap Next to continue, or Skip if you do not want the device to be password- protected.
Figure 12. Password setup

Follow the onscreen instructions to enter your password. Reference the Microsoft help system on your device for more information. You can return to the Password screen anytime by tapping > Settings > Personal > Lock.

Windows Zero Config should be used to administer the radio setup. For assis- tance in configuring the radio card, reference the online help on your Falcon. Go to > Help for further information.
To open an application, tap a link on the Today page, or tap > Programs to display a list of available programs. Tap a program icon to open it.
There are several ways to enter data with the Falcon:
Entering Data

Never use a pen, pencil, or other sharp object on the Falcon’s touchscreen dis- play. Use only the supplied stylus or plastic-tipped pens intended for use with a touch-sensitive display. Contact your reseller to replace a missing stylus; refer to the PSC price book at www.psc.com
The stylus is located next to the scanning pod as illustrated in Figure 13. The stylus on the Falcon is the equivalent of the mouse on a PC. Use the stylus to:
Figure 13. Back View of a Falcon 4420 with a Stylus


It is good practice to replace the stylus in the holder after each use so you don’t misplace it. An optional Tethered Stylus is also available, preventing accidental loss of the stylus.
Entering Data · Scanner Pod · Stylus Stylus Holder

Figure 14. Tethered Stylus


There are several navigation areas on your display, including the title bar and the soft key bar. Each of these navigation areas have sub-areas of navigation as well. Take the time to familiarize yourself with these features to save yourself valuable time.
After initial startup, the first screen you will see will be the Today screen (unless your device has been customized differently). You can also access the Today Screen anytime by tapping > Today.
The Title bar at the top of the screen shows Connection status, a link to Vol- ume control, and Time/Date settings.
Entering Data · Tethered Stylus

Figure 15. The Today Screen

The Title bar at the top of the screen contains the Start icon, program name, and notification icons. Tap (Start) to open the Start menu. The Start menu includes access to Programs, Settings, Help and shortcuts to programs and func- tions.
The soft key bar at the bottom of the screen provides context-sensitive menus for tasks in programs, such as opening a file, saving a file, or editing a file.
Figure 16. Start Menu

Entering Data · Start Menu

In applications that accept keyed input, the on-screen keyboard can be used to enter data using the stylus. The on-screen keyboard is a digital, QWERTY- style keyboard. Tap the Keyboard icon to open or close the on-screen keyboard.
Figure 17. On-Screen Keyboard


Use the stylus to select letters, numbers, or symbols from the on-screen key- board for the current application. Tap the key to change the keypad to show international letters.
You can also set up the Falcon to use Block Recognizer, Letter Recognizer, or Transcriber to enter data. Reference the help system on the Falcon for more information on these features.
The Settings screen has three tabs: Personal, System and Connections. Each provides access to various options. Tap > Settings to open the Settings screen, then tap the tab you want to access.
Entering Data · Keyboard Icon

Figure 18. Settings screen

Tap > Programs to open the Programs screen to view and open the avail- able Programs on your Falcon. Tap a program to open it.
Figure 19. Programs screen


Refer to the Falcon 4400 PRG for more information on configuring the key- pads.
The Falcon is available with several different keypad models:
There are a number of keys that are common to the different keypad models. Table 4 lists special function keys that are found on several keypads, as well as those which are unique to specific keypads.
Table 4. Keypad Overview - Special Keys
Key Name Keypad Model(s) Function/Description
<Alpha> 26-key Press <Alpha> to access lower case alpha characters and symbols on the 26- key keypad. Alpha- Numeric
All In Normal mode, use the alpha-numeric keys to enter numbers and letters. In Shift and CAPS modes, the alpha-numeric keys enter upper case letters.
26-key 48-key <BACKLIGHT> toggles the Backlight on or off when you press it.
<Fn> All Press <Fn> to enter the FN input state. Use FN mode to access additional fea- tures and operations.
<POWER> All Press
<Scan> 26-key 52-key Press <Scan> to activate the laser scanner.

Key Name Keypad Model(s) Function/Description
<Ctrl> 48-key Set keyboard shortcuts like a PC with <Ctrl> You can perform functions such as Save (Ctrl-s) and Find (Ctrl-f). Toggle on and off for text formatting (for example, Ctrl-b for bold, Ctrl-i for italics, Ctrl-u for underline).
<Alt> 48-key 52-key Press <Alt> to enter the Alt input state. Use Alt mode to access application menus.
<Shift> 48-key 52-key Press the <Shift> key to enter Shift input states. Use Shift mode to output upper-case characters and punctuation (identified over number keys).
The Keyboard Indicators are visible in the Title Bar at the top of the screen. The most recently activated state is on the left if more than one state is active.
Figure 20. Keyboard Indicators

Scroll between icons to view the active modes.
Entering Data · Keyboard Indicators · Keyboard Indicators

Table 5. Input States and their Indicators
Icon State Keypad Model(s) Function
26-key Present only on keypads with an <Alpha> key. It appears when Alpha or CAPS modes are not on.
Press <Alpha> to enter lower case alpha characters and symbols. When in Alpha mode, the current alpha character is displayed by a keyboard indicator.
Alpha mode is persistent, which means that the system stays in Alpha mode until you press <Alpha> again.
Press <Fn> + <Alpha> to activate CAPS mode. CAPS mode generates upper case alpha characters A-Z.
CAPS mode is persistent; press the <Fn> + <Alpha> keys again to generate lower case characters. Punctuation keys are not affected.
Press <Fn> + <Shift> to activate Caps mode. Caps mode generates upper case alpha characters A-Z.
CAPS mode is normally persistent; you must press <Fn> + <Shift> again to gen- erate lower case characters. Punctuation keys are not affected. If CAPS is active, and SHIFT is active, no icon is displayed.
26-key Press <Fn> to enter FN mode.
<Fn> is independent of <Alpha>. Use FN mode to access the features and oper- ations on the keypad. 48-key 52-key Fn mode converts alpha keys to punctuation and function keys. Fn mode is acti- vated by pressing <Fn>.
Shift mode converts characters to upper-case letters or punctuation. Activated by pressing <Shift>. This state expires after a normal key is pressed unless <Shift> is held down.
Toggles to make the next alpha character capitalized. If Shift state is active when the Caps State is active, no icon is displayed.
On the 48-key keypad, converts keys to system keys that allow users to access the menu. Activated by pressing
Alt Mode 48-key 52-key
Ctrl Mode 48-key Set keyboard shortcuts with <Ctrl>. You can perform functions such as Save (Ctrl-s) and Find (Ctrl-f). Toggle on and off for text formatting (for example, Ctrl-b for bold, Ctrl-i for italics, Ctrl-u for underline).

The 26-key keypad is organized like a cell phone, with multi-tap access to alpha characters on numeric keys (see Figure 21). Use the ten (10) alpha- numeric keys and <Esc> to type letters, numbers, and symbols listed in Table 6 on page 30.
Figure 21. 26-Key Keypad

POWER
26-Key Functions. Most of the keys on the keypad of the Falcon have more than one function. To access the secondary features and functions, you must first press another key to access the desired input state.
Alpha-Numeric Keys. Press the keys in Table 6 once, twice, or more times to cycle through the alpha letters and symbols until the desired character appears in the Title bar. After the last letter or symbol in the sequence for that key, the next keypress will generate the first letter or symbol in the sequence.

Table 6. 26-Key Keypad Alpha Characters and Symbols
Fifth Keypress : / @ : / , \ * , \ A B C A B D E F D E G H I G H J K L J K M N O M N P Q R S P T U V T U W X Y Z W
The 48-key keypad is designed so you can type all letters and numbers without requiring multiple key presses.
Figure 22. 48-Key Keypad

Some of the keys on the 48-key keypad of the Falcon have more than one function. To access the secondary features and functions, you must first press

another key to access the desired input state. See Table 4 on page 26 for fur- ther information.
Press <Backlight> to toggle the backlight on or off. Press <Fn>+<Backlight> to adjust the brightness. Press <ENTER> to accept the changes.
The input states for the 48-key keypad are <Shift>, <Ctrl>, <Alt>, and <Fn>. Each state is described in Table 5 on page 28.
The standard 52-key keypad is designed to allow you to type all letters and numbers without requiring multiple key presses.
Figure 23. 52-Key Keypad

. (Backlight)
Some of the keys on the keypad of the Falcon have more than one function. To access the secondary features and functions, you must first press another key to access the desired input state. See Table 4 on page 26 for more information.

Press <Fn>+< . > (period/decimal) to toggle the backlight on or off. To adjust the brightness, press <Fn>+<Alt> or tap > Settings > System > Backlight. Press <ENTER> to accept the changes.
The input states for the 52-key keypad are <Shift>, <Alt>, and <Fn>. Each is described in Table 5 on page 28.
The control panel for the 52-key keypad has some additional options and an additional tab for key mapping.
The 5250 52-key keypad is designed to provide the keyboard functions needed to run 5250 terminal emulation software.
The 5250 keypad is a remapped version of the 52-key model.
Figure 24. 5250 Keypad

. (Backlight)

Laser Scanning
To use the scanning function on units containing a laser scanning module, complete the following steps:
Figure 25. Scanning a bar code

Press <Scan> (on 26 and 52- key) or the Scan Trigger to ini- tiate a scan with the Falcon.
Scanning Bar Codes


Ideal positioning A bit high, will read correctly A bit angled, will read correctly
Positioned too far to the right. Will not read entire bar code.
Bar code will not read. The scanner should be posi- tioned perpendicular to the bar code bars.
If the bar code scan failed, adjust the reading angle or distance. Make sure that the laser beam scans across all bars of the bar code. Refer to Figure 26.
Refer to the section on Scanner Configuration in the PRG to modify the default settings.
Scanning Bar Codes

Scanning bar codes with the 2D imaging device is similar to scanning with a laser scanner. The operation and configuration of the scanner is performed in the same way as laser scanning devices. Trigger behavior and scanning time- outs are the same as laser scanning devices.
The imager contains an aiming beam rather than a red laser. The aiming beam mimics a laser line for purposes of orienting the imager to a bar code. Figure 27 shows how the aiming beam visually differs from the laser beam in laser scanning devices.
Figure 27. Laser vs. Imaging beam

Rotational orientation does not affect the imager module's ability to read bar codes. For example, the imager can read a bar code when the aimer beam is parallel to the lines of the bar code. What is important is the location of the aimer in relation to the center of the bar code. The aiming beam should be centered over the bar code, but it can be positioned in any direction for a good read.

Figure 28. Aiming Beam Positioning
Linear bar codes 2D Matrix symbol



The aiming beam is smaller when the imager is closer to the code and larger when it is farther away. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. To scan a label, hold the imager at an appropriate distance from the target, pull the trigger, and center the aim- ing beam on the symbol.
Another feature that can be enabled for 2D scanning is an array of illumina- tion LEDs. These LEDs provide illumination in dark environments and can improve scanning performance under certain lighting conditions. By default, the illumination LEDs are turned on. Illumination LEDs can be disabled using the PDT parameters. See the PRG for complete information on pro- gramming the LEDs.
Scanning Bar Codes

Optical character recognition (OCR) decodes certain fonts and outputs the data as a string, in a similar fashion to bar code labels. The Falcon 2D Imager supports limited decoding of some OCR fonts. See the PRG for information on setup and programming for OCR fonts.
The 2D Imager can be used for capturing, manipulating, and transferring images.
You can set options for image capture in the Imaging Control Panel. Various image formats can be selected, including TIFF, JPEG and BMP. You can also scale, rotate, and modify image quality settings. See the PRG for detailed infor- mation on using the Falcon 2D for image capture.
Access Microsoft Windows Mobile help by tapping > Help from any screen.
Figure 29. Using Windows Mobile Context Sensitive Help


Additionally, you can tap the in the upper right corner of some screens to access context sensitive help for that screen.
Image Capture

There are several reset methods for the Falcon.
Once you initiate a Clean Boot, all applications are forcibly closed and installed applications and data are deleted. PSC recommends that you first attempt a Warm Reset, then a Hard Reset, before initiating a Clean Boot.
DO NOT use a sharp object to reset. Sharp objects can puncture the keypad, disabling the reset function, rupturing the Falcon’s industrial seal, and voiding your warranty. PSC recommends using a straightened paper clip
Warm Reset
A Warm Reset is a complete reset of the Falcon in which all applications are forcibly closed and working RAM is cleared.
Reason to Warm Reset. Perform a Warm Reset when the Windows Mobile operating system locks up and you cannot reset a “hung” application using the Settings, as described above.
The reset procedure varies, depending upon the keypad on your Falcon. The first two keys of the sequence can be pressed in any order, but the unit will not reset until they both are held down and then the third key (<Bksp> or <F1>) is pressed. All three keys must be held down for the unit to reset. Refer to Figure 30 for the location of the reset keys.
26-Key Falcon. Press and hold: <FN>+<Alpha>+<Bksp>.
48-Key Falcon. Press and hold: <Ctrl>+<Alt>+<Bksp>.
Resetting the Falcon

52-Key Falcon. Press and hold: <ALT>+<FN>+<F1>.
Figure 30. Warm Reset Key Sequence




When a Falcon goes through the Warm Reset sequence, it clears the working RAM and initializes the file system.
The splash screen will appear after a short period.
A Hard Reset is a complete reset of the Falcon in which all applications are forcibly closed, working RAM is cleared, and the system time and date are reset.
Reason to Hard Reset. Perform a Hard Reset when the Windows Mobile operating system locks up and you cannot reset a “hung” application using the Settings or Warm Reset, as described above.
Resetting the Falcon

Once you initiate a Hard Reset, all applications are forcibly closed, working RAM and files are cleared, and the Real Time clock is reset.
Any files or data in RAM will be lost if you Hard Reset.
Do not use a sharp object to perform a Hard Reset, as this can puncture the key- pad, disabling the reset function, rupturing the Falcon industrial seal, and voiding your warranty. PSC recommends using a straightened paper clip.
Procedure to Hard Reset. To perform a Hard Reset, insert a paper clip into the <Reset> aperture while pressing the <POWER> button (refer to Figure 31).
Figure 31. Hard Reset Key Sequence
: / @
A B C
G H I
J K L
M N O
P Q R S W X Y Z T U V
After Hard Reset
When a Falcon goes through the Hard Reset sequence, it clears the working RAM, initializes the file system and resets the system time and date.
The splash screen will appear after a short period.

A Clean Boot is a complete reset of the Falcon in which all applications are forcibly closed and the Falcon is restored to factory defaults. ALL USER- INSTALLED PROGRAMS, DATA AND REGISTRY SETTINGS ON THE DISK WILL BE ERASED.
Reason to perform a Clean Boot. Use Clean Boot if the Windows Mobile operating system locks up and the Hard Reset command does not work.
Once you initiate a Clean Boot, all applications are forcibly closed and installed applications and data are deleted. PSC recommends that you first attempt a Warm Reset, then a Hard Reset, before initiating a Clean Boot.
DO NOT use a sharp object to reset. Sharp objects can puncture the keypad, disabling the reset function, rupturing the Falcon’s industrial seal, and voiding your warranty.
Procedure to perform a Clean Boot. The procedure is the same for all keyboards. To perform a Clean Boot:
The Splash screen will appear after you remove the reset pin from the hole.
Resetting the Falcon

Figure 32. Clean Boot key sequence

P Q R S W X Y Z T U V
When a Falcon goes through the Clean Boot sequence, it clears the working memory and initializes the file system. You will lose all user-installed applica- tions, custom registry settings and data.
Resetting the Falcon

Refer to the Falcon 4400 with Windows Mobile® PRG for more information.
Table 7. Troubleshooting Problems, Causes, and Solutions
Problem Possible Cause Solution
The Falcon does not turn on.
The battery pack is not installed properly.
Ensure the battery is installed properly.
The battery is not fully charged. Insert the Falcon in dock and begin charging. The bat-
tery pack backup battery and require 24 hours to fully charge at first use, and 4 hours thereafter.
System failure. Perform a Hard Reset or a Clean Boot. Refer to Reset- ting the Falcon starting on page 38.
Rechargeable battery pack did not charge.
Battery failure. Replace the battery. If the Falcon terminal still does not operate, try a Hard Reset then a Clean Boot; refer to Resetting the Falcon starting on page 38.
The Falcon was removed from the dock while battery was charging.
Insert the Falcon in dock and begin charging. The bat- tery pack and backup battery require 4 hours to fully charge.
Characters are not visible on the display.
The Falcon is not powered on. Press <POWER>.
The ambient room light is too dark or low.
Turn on the backlight. Refer to the PRG.
No sound is audible. Volume setting is low or turned off.
Adjust the sound volume by going to the Volume icon on the Task bar at the top of the screen.
The expected sound is not con- figured in the software.
Ensure that sounds are enabled by tapping > Settings > Personal > Sounds & Notifications, or
> Settings > System > Decoding for sounds related to bar code scanning.
Scan the appropriate bar code from the PRG.
The Falcon turns itself off. The Falcon is inactive. The Falcon turns off after a period of inactivity. You can set duration from one to 30 minutes. Refer to the PRG to modify the default settings.
The Falcon will not accept input from the stylus or the keypad.
A software application is “hung.” Tap > Settings > System > Memory > Running Programs. Select the problematic pro- gram(s) and tap Stop, or Stop All to stop all running programs.
System failure. Perform a Hard Reset or a Clean Boot. Refer to Reset- ting the Falcon starting on page 38.
Troubleshooting

Problem Possible Cause Solution
During data communication, no data was transmitted, or transmitted data was incomplete.
The Falcon was removed from the dock or unplugged from host PC during communications.
Replace the terminal in the dock, or replace the serial cable, and retransmit.
Incorrect cable configuration. See your System Administrator.
Communication software was incorrectly installed or config- ured.
Perform setup as described in the PRG.
The Falcon does not accept scan input.
The scanning window is dirty. Carefully wipe the scanning window with a soft, clean cloth. Do not use abrasive cleaners.
The scanning application is not loaded.
Verify that the unit is loaded with a scanning applica- tion. See your System Administrator.
Unreadable bar code. Be sure the symbol is not defaced.
Distance between exit window and bar code is incorrect.
Be sure you are within proper scanning range.
The Falcon is not programmed for that symbology.
Be sure the terminal is programmed to accept the type of bar code you are scanning. Try using FF3A to turn on maximum defaults, as described in “Programming Parameters” in the Falcon 4400 PRG.
The Falcon is not programmed to generate a beep.
If you are expecting a beep on a good decode and don’t hear one, check that the application is set to gen- erate a beep on good decode.
Tap > Settings > System > Decoding > Gen- eral > Audio
Scan the appropriate bar code from the PRG.
Battery is low. If the scanner stops emitting a laser beam when you press the trigger, check your battery level. Refer to the PRG.
The UPC/EAN extension (supplemental label) is not always scanned.
Laser beam only crosses over base of UPC/EAN label.
Set the Read Verification for extensions (parameter 0528) to a value lower than the Read Verification for the base label. See the PRG.
Troubleshooting

Problem Possible Cause Solution
The Spare Battery LED on the dock is flashing RED.
Time-out fault: the spare bat- tery pack charging has exceeded the maximum time- out period.
In either case, if the Spare Battery LED is flashing red, do the following: 1. Disconnect the AC adapter from the dock. 2. Remove the spare battery pack and the Falcon from the dock. 3. Connect the AC adapter to the dock. 4. If the Spare Battery LED is flashing red, there is a problem with the dock. Disconnect the AC adapter from the dock and contact a service technician. 5. If the Spare Battery LED is off, insert a different spare battery pack in the dock. 6. If, in the course of charging the spare battery, the Spare Battery LED is flashing red, there is a problem with the dock. Disconnect the AC adapter from the dock and contact a service technician. 7. Otherwise, there is a problem with the first spare battery pack. Discontinue use of the first spare bat- tery pack. Refer to the PRG for instructions on bat- tery disposal.
Over-voltage fault: the spare battery pack charging has exceeded the maximum charge voltage of the battery.
Troubleshooting

NO
YES display an error during the
Does the Falcon respond to a PING
Contact Tech Support.
NO
Does the Falcon associate with the AP
: Potential Problems
Ping Falcon from host or use tracert to determine the location of the breakdown in communication.
Can you ping the Falcon from the AP
NO NO
Does the Falcon connect to the host ?
Can you ping the host from a PC on same
YES
RF connectivity obtained. See your software manual for further information or contact PSC technical support.
(For more information on the Ping command, go to the command prompt on the PC and type PING. For more information on the trace route command, go to the command prompt on the PC and type tracert.)

PSC Website Support
The PSC website (www.psc.com) is the complete source for technical support and information for PSC products. The site offers the PSC TekForum, prod- uct support, product registration, warranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair.
Search for information on the TekForum by clicking on the Support link on the PSC home page. Browse the TekForum to find answers to your questions about common technical issues.
An excellent source for technical assistance and information is an authorized PSC reseller. A reseller is acquainted with specific types of businesses, applica- tion software, and computer systems and can provide individualized assistance.
If you do not have internet or email access, you may contact PSC technical support at (541) 349-8281.
Technical Support

Technical Support

End User License Agreement
Notice to End User: The product you have acquired contains software, which is integral to the product's operation. This soft- ware is provided only for use with, and for authorized end users of, the PSC Falcon® 44xx series Portable Computing Device (“PSC Product”). The PSC Product operates with PSC software, including but not limited to, PSC documentation and all PSC software applications and software tools (e.g. Falcon Update Utility, Falcon Management Utility, and Falcon desktop Utility)(“Soft- ware”) and the PSC Product also operates with either Microsoft Windows®CE .NET or Windows® Mobile™ 5.0 software (“SOFTWARE”) (see Microsoft Addendum for specific terms and conditions)(hereinafter collectively referred to as “Software”).
Software is provided only for use with the PSC Product and any other use of Software is strictly prohibited and may subject you to legal action. Software is provided to you under license, subject to the terms and conditions of this end user license agreement (“EULA”). Any and all updates to Software shall also be subject to this EULA. In the event upgrades are made available, you will be authorized to order only one upgrade for each licensed PSC Product. If you use the PSC Product, you will be deemed to have accepted the terms and conditions of this EULA. If you do not intend to be bound to the terms of this EULA, PSC is not willing to license the Software to you, you may not use the PSC Product or the Software, and you must contact the party from whom you acquired the PSC Product for instructions on how to return the PSC Product.
This End User Software License Agreement (\"EULA\") is a legally binding agreement governing the licensing of the Software and Documentation by PSC Inc. and its wholly owned subsidiaries and affiliates (\"PSC\") to the entity or person who has pur- chased or otherwise acquired a PSC Product (\"End User\"). For purposes of this EULA, any software that is associated with a separate end-user license agreement is licensed to you under the terms of that license agreement. PSC and End User hereby agree as follows:
1.1 \"Documentation\" means materials such as user's guides, program reference guides, quick reference guides, manuals, or similar materials associated with or related to the PSC Product, whether in printed, \"online\", or other form.
1.2 \"Proprietary Information\" means: (a) source code, object code, software, documentation, and any related internal design, system design, data base design, algorithms, technology, technical data or information, implementation techniques, and trade secrets related to the Software, (b) any other trade secrets marked appropriately or identified as proprietary or confidential, and (c) any information that End User, under the circumstances, should recognize as confidential. Proprietary Information does not include any information that the receiving party can establish was (1) in the public domain, (2) already in the receiving party's possession or rightfully known prior to receipt, (3) rightfully learned from a third party not in violation of any other's proprietary rights, or (4) independently developed without access to Proprietary Information.
1.3 \"PSC Product\" means PSC's FALCON® Windows®CE .NET and/or Windows Mobile 5.0 44xx Series, including all pre- loaded Software in or provided in connection with the PSC Product and all Documentation related to such product, which has been purchased or otherwise acquired by End User, whether obtained directly or indirectly from PSC.
1.4 \"Software\" means any software or computer program of PSC or its third party licensors in machine readable form which is either preloaded in, or provided in connection with, the PSC Product, whether obtained directly or indirectly from PSC, including any related update or upgrade such as enhancements or modifications.
2.1 PSC grants to End User a non-exclusive, non- transferable, perpetual license to use the Software, solely on a PSC Product, in machine- readable form only, solely for End User's internal business purposes. This EULA does not convey ownership of the Software to End User. Title to the Software shall be and remain with PSC or the third party from whom PSC has obtained a licensed right. As used in this EULA, the term \"purchase\" or its equivalents when applied to the Software shall mean \"acquire under license.\"
2.2 End User shall not copy, modify, decompile, disassemble, reverse engineer, or otherwise reproduce or remanufacture the Software, whether modified or unmodified, nor sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Soft- ware to any other person or organization, for purposes other than as expressly provided in this EULA, without PSC's prior written consent.

3.1 Any copying, installing, reproduction, remanufacture, reverse engineering, electronic transfer, or other use of the Software on other than a PSC Product will be a material breach of this EULA.
3.2 End User shall not sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer a PSC Product containing Soft- ware to any third party unless such third party agrees with PSC in writing to be bound by the terms and conditions of this EULA. Any such transfer of a PSC Product absent such agreement shall be null and void.
3.3 End User may obtain support for Software from PSC at PSC's standard support fees and under PSC's standard support terms and conditions in effect at the time the support is requested.
End User acknowledges that the Software constitutes valuable trade secrets of PSC or PSC's third party licensors and that the Software is protected by intellectual property laws and treaties. The license set forth in this EULA does not transfer to End User any ownership of PSC's or of its third party licensors' copyrights, patents, trademarks, service marks, trade secrets, or other intellectual property rights and End User shall have no right to commence any legal actions to obtain such rights. End User shall not remove, modify, or take any other action that would obscure any copyright, trademark, patent marking, or other intellectual property notices contained in or on the PSC Product.
5.1 End User acknowledges that Proprietary Information is the confidential, proprietary, and trade secret property of PSC and PSC's third party licensors and End User acquires no right or interest in any Proprietary Information.
5.2 End User shall not disclose, provide, or otherwise make available the Proprietary Information of PSC or its third party licen- sors to any person other than End User's authorized employees or agents who are under confidentiality agreement, and End User shall not use the Proprietary Information other than in conjunction with use of the PSC Product exclusively for End User's internal business purposes. End User shall take steps to protect the Proprietary Information no less securely than if it were End User's own intellectual property.
5.3 The provisions of this Proprietary Information Section shall survive and continue for five (5) years after the termination of this EULA.
6.1 PSC warrants that, under normal use and operation, the PSC Product will conform substantially to the applicable Documen- tation for the period specified in the Documentation. During this period, for all reproducible nonconformities for which PSC has been given written notice, PSC will use commercially reasonable efforts to remedy nonconformities verified by PSC. End User agrees to supply PSC with all reasonably requested information and assistance necessary to help PSC in remedying such non- conformities. For all defects reported to PSC within the warranty period, PSC's liability is limited to providing End User with one copy of corrections or responding to End User's problem reports according to PSC's standard assistance practices. PSC does not warrant that the product will meet End User's requirements or that use of the product will be uninterrupted or error free, or that PSC's remedial efforts will correct any non-conformance.
This limited warranty does not cover any product that has been subjected to damage or abuse, whether intentionally, acciden- tally, or by neglect, or to unauthorized repair or unauthorized installation, and shall be void if End User modifies the product, uses the product in any manner other than as established in the Documentation, or if End User breaches any of the provisions of this EULA.
6.2 EXCEPT AS PROVIDED IN THIS EULA, THE PSC PRODUCT IS PROVIDED \"AS IS\" AND PSC MAKES NO WARRAN- TIES OF ANY KIND, EXPRESS OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PRODUCT, AND SPECIFI- CALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
7.1 PSC will defend End User against any claim in a lawsuit that the PSC Product furnished hereunder infringes a United States patent or copyright of a third party and PSC will pay any damages finally awarded against End User by a court of competent jurisdiction that are directly attributable to such claim or will pay End User's part of any settlement that is attributable to such claim, provided, that 1) End User notifies PSC promptly in writing of the claim, 2) PSC controls the defense or settlement of the claim, and 3) End User cooperates fully with PSC in such defense or settlement. All notices of a claim should be sent to PSC Inc, 959 Terry Street, Eugene, OR 97402.
7.2 In the defense or settlement of any such claim, PSC may, at its option, 1) procure for End User the right to continue using the PSC Product, 2) modify the PSC Product so that it becomes non- infringing, 3) replace the PSC Product with an equivalent prod- uct not subject to such claim, or 4) provide End User an opportunity to return the PSC Product and receive a refund of the pur- chase price paid, less a reasonable allowance for use.

7.3 PSC shall have no liability to End User for claims of infringement based upon 1) the use of any PSC Product in combination with any product which PSC has not either furnished or authorized for use with such PSC Product 2) the use of any PSC Product designed, manufactured, or modified to the specifications of End User, or 3) End User's modification of the PSC Product without written authorization from PSC.
7.4 THE FOREGOING STATES PSC'S COMPLETE AND ENTIRE OBLIGATION CONCERNING CLAIMS OF PATENT, COPY- RIGHT, OR OTHER INTELLECTUAL PROPERTY INFRINGEMENT, CANCELS AND SUPERCEDES ANY PRIOR AGREE- MENTS, WHETHER ORAL OR WRITTEN, BETWEEN THE PARTIES CONCERNING SUCH CLAIMS, AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST, CONTEMPORANEOUS, OR FUTURE AGREEMENTS OR DEALINGS BETWEEN THE PARTIES, WHETHER ORAL OR WRITTEN, EXCEPT AS SET FORTH IN A FUTURE WRITING SIGNED BY BOTH PAR- TIES.
EXCEPT AS PROVIDED IN SECTION 7 (above), PSC SHALL NOT BE LIABLE FOR ANY CLAIMS AGAINST END USER BYANY OTHER PARTY. IN NO EVENT SHALL PSC'S LIABILITY FOR DAMAGES, IF ANY, WHETHER BASED UPON CON- TRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER BASIS, EXCEED THE PRICE OR FEE PAID BY END USER FOR THE PSC PRODUCT. UNDER NO CIRCUMSTANCES SHALL PSC BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR SERVICE, OR FOR ANY OTHER SPECIAL, CONSEQUENTIAL, CONTINGENT, INDIRECT, INCIDENTAL, PUNITIVE, EXEM- PLARY, OR OTHER SIMILAR DAMAGES, EVEN IF PSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
9.1 Use, duplication, or disclosure of the Software by the U.S. Government is subject to the restrictions for computer software developed at private expense as set forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or 52.227-19 or in the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013(c)(1)(ii), whichever is applicable.
9.2 If End User is using the PSC Product outside of the United States, End User must comply with the applicable local laws of the country in which the PSC Product is used, with U.S. export control laws, and with the English language version of this EULA. The provisions of the \"United Nations Convention on International Sale of Goods\" shall not apply to this EULA.
10.1 Either party may terminate this EULA or any license granted under this EULA at any time upon written notice if the other party breaches any provision of this EULA.
10.2 Upon termination of this EULA, End User immediately shall cease using any non-preloaded software and shall return to PSC or destroy all non-preloaded software covered by this EULA, and shall furnish PSC with a certificate of compliance with this provision signed by an officer or authorized representative of End User. For preloaded software, End User agrees to sign a waiver prepared by PSC concerning further use of the preloaded Software. End User's resumed or continued use of the pre- loaded Software after termination shall constitute End User's agreement to be bound by the terms and conditions of this EULA for such use.
11.1 Entire EULA; Amendment. This document contains the entire agreement between the parties relating to the licensing of the Software and supersedes all prior or contemporaneous agreements, written or oral, between the parties concerning the licensing of the Software. This EULA may not be changed, amended, or modified except by written document signed by PSC.
11.2 Notice. All notices required or authorized under this EULA shall be given in writing, and shall be effective when received, with evidence of receipt. Notices to PSC shall be sent to the Legal Department, attention Contracts Administration, PSC Inc., 959 Terry Street, Eugene, OR 97402, or such other address as may be specified by PSC in writing.
11.3 Waiver. A party's failure to enforce any of the terms and conditions of this EULA shall not prevent the party's later enforce- ment of such terms and conditions.
11.4 Governing Law; Venue: This EULA and the rights of the parties hereunder shall be governed by and construed in accor- dance with the laws of the State of Oregon U.S.A, without regard to the rules governing conflicts of law. The state or federal courts of the State of Oregon located in either Multnomah or Lane counties shall have exclusive jurisdiction over all matters regarding this EULA, except that PSC shall have the right, at its absolute discretion, to initiate proceedings in the courts of any other state, country, or territory in which End User resides, or in which any of End User's assets are located.
11.5 Attorneys' Fees. In the event an action is brought to enforce the terms and conditions of this EULA, the prevailing party shall be entitled to reasonable attorneys' fees, both at trial and on appeal.

Addendum to EULA
GRANT OF SOFTWARE LICENSE. This EULA grants you the following license:
DEVICE Software. You may use the DEVICE Software as installed on the DEVICE.
Companion CD. A Companion CD is included with your DEVICE, and you may install and use the Microsoft® ActiveSync® com- ponent on one (1) or more personal computers to exchange information with one (1) or more computing devices that contain a compatible version of the Microsoft® Windows Mobile™ Version 5.0 operating system. For other software component(s) con- tained on the Companion CD, you may install and use such components only in accordance with the terms of the printed or online end user license agreement(s) provided with such component(s). In the absence of an end user license agreement for particular component(s) of the Companion CD, you may install and use only one (1) copy of such component(s) on the DEVICE or a single personal computer with which you use the DEVICE.
Phone Functionality. If the DEVICE Software includes phone functionality, all or certain portions of the DEVICE Software may be inoperable if you do not have and maintain a service account with an appropriate wireless telecommunication carrier to whom PSC may distribute its DEVICES (“Mobile Operator”),or if the Mobile Operator’s network facilities are not operating or configured to operate with the DEVICE.
Microsoft® Outlook®. If Microsoft Outlook is included with your Device, the following terms apply to your use of Microsoft Out- look: (i) regardless of the information contained in the “Software Installation and Use” section of the online EULA you may install one (1) copy of Microsoft Outlook on one (1) personal computer to use, exchange data, share data, access and interact with the DEVICE, and (ii) the EULA for Microsoft Outlook is between PSC and the end user – not between the PC manufacturer and end user.
DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS.

If you have questions regarding this Notice, please contact MPEG LA, L.L.C., 250 Steele Street, Suite 300, Denver, Colorado 80206; Telephone 303 331.1880; FAX 303 331.1879 • Rental. You may not rent, lease, or lend the SOFTWARE.
If the DEVICE Software includes phone functionality, you may not permanently transfer any of your rights under this EULA with regard to the DEVICE Software or Companion CD, except as permitted by the applicable Mobile Operator. In the event that the Mobile Operator permits such transfer, you may permanently transfer all of your rights under this EULA only as part of a sale or transfer of the DEVICE, provided you retain no copies, you transfer all of the SOFTWARE (including all component parts, the media and printed materials, any upgrades, this EULA and, if applicable, the Certificate(s) of Authenticity), and the recipient agrees to the terms of this EULA. If the SOFTWARE is an upgrade, any transfer must include all prior versions of the SOFT- WARE.

UPGRADES AND RECOVERY MEDIA.
COPYRIGHT. All title and intellectual property rights in and to the SOFTWARE (including but not limited to any images, photo- graphs, animations, video, audio, music, text and “applets,” incorporated into the SOFTWARE), the accompanying printed mate- rials, and any copies of the SOFTWARE, are owned by MS or its suppliers (including Microsoft Corporation). You may not copy the printed materials accompanying the SOFTWARE. All title and intellectual property rights in and to the content which may be accessed through use of the SOFTWARE is the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties. This EULA grants you no rights to use such content. All rights not spe- cifically granted under this EULA are reserved by MS and its suppliers (including Microsoft Corporation).
EXPORT RESTRICTIONS. You acknowledge that the SOFTWARE is subject to U.S. and EU export jurisdiction. You agree to comply with all applicable international and national laws that apply to the SOFTWARE, including the U.S. Export Administration Regulations, as well as end-user, end-use and destination restrictions issued by U.S. and other governments. For additional information, see http://www.microsoft.com/exporting/
PRODUCT SUPPORT. Product support for the SOFTWARE is not provided by MS, its parent corporation Microsoft Corporation, or their affiliates or subsidiaries. For product support, please refer to PSC support number provided in the documentation for the DEVICE. Should you have any questions concerning this EULA, or if you desire to contact PSC for any other reason, please refer to the address provided in the documentation for the DEVICE.
NO LIABILTIY FOR CERTAIN DAMAGES. EXCEPT AS PROHIBITED BY LAW, MICROSOFT CORPORATION AND ITS AFFILIATES SHALL HAVE NO LIABILITY FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE SOFTWARE. THIS LIMITATION SHALL APPLY EVEN IF ANY REMEDY FAILS OF ITS ESSENTIAL PURPOSE.
FOR APPLICABLE LIMITED WARRANTIES AND SPECIAL PROVISIONS PERTAINING TO YOUR PARTICULAR JURISDIC- TION, PLEASE REFER TO YOUR WARRANTY BOOKLET INCLUDED WITH THIS PACKAGE OR PROVIDED WITH THE SOFTWARE PRINTED MATERIALS.

Product Series Warranty
Falcon products are guaranteed against defects in materials and workmanship for the period specified at the time of sale. This warranty shall apply to Falcon Portable Data Terminals (PDT's), Base Stations for the Falcon and Chargers for the Falcon. Cables, mounts and other accessory items are specifically warranted for a period of 90-days from product purchase. Customer must notify PSC of the claimed defect before the expiration of the Warranty period and obtain from PSC a return authorization number for return of the product to designated PSC service center. If PSC determines Customer’s claim is valid, PSC will repair or replace product without additional charge for parts and labor. Customer shall be responsible for packaging and shipping the product to the designated PSC service center, with shipping charges prepaid. PSC shall pay for the return of the product to Cus- tomer if the shipment is to a location within the country in which the PSC service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
Warranty is subject to the limitations and exclusions set forth in the paragraphs that follow.
WARRANTY SET FORTH ABOVE IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MER- CHANTABILITY AND FITNESS.
Warranty coverage shall not apply to any claimed defect, failure or damage which PSC determines was caused by: abuse, neglect, improper use of product; failure to provide product maintenance, including but not limited to cleaning of the display in accordance with product reference guide; installation or service of product by other than PSC representatives; use of product with any other instrument, equipment or apparatus; modification or alteration of product or units with Warranty Void labels that have been tampered with. External cables and replacement of upper window/cartridge due to scratching, stains or other degra- dation will not be covered under the Warranty. External power supplies returned for service must be accompanied by the original product for performance of service.
Returned products that PSC inc. has determined are not covered by Warranty, will be charged PSC Inc. standard repair rates then in effect for repair of product. Replacement of display due to scratching, stains or other degradation will not be covered under Warranty. If a product is determined to be not repairable customer will be notified and product may be returned to cus- tomer at their request. A minimum repair fee may be charged.
PSC's REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCT AS SET FORTH ABOVE IS THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY ON ACCOUNT OF CLAIMS OF BREACH OF WARRANTY OR PRODUCT DEFECT. UNDER NO CIR- CUMSTANCES WILL PSC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCI- DENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES REGARDLESS OF WHETHER PSC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Customer may not assign or otherwise transfer its rights or obligations under Warranty except to a purchaser or transferee of product. No attempted assignment or transfer in violation of this provision shall be valid or binding upon PSC.
Customer shall bear risk of loss or damage for product in transit to PSC. PSC shall assume risk of loss or damage for product in PSC's possession or product being returned to Customer by PSC, except such loss or damage as may be caused by the negli- gence of Customer, its agents or employees. In the absence of specific written instructions for the return of product to Customer, PSC will select the carrier, but PSC shall not thereby assume any liability in connection with the return shipment.

Figure 1. Laser Safety Label
PSC 959 Terry St. Eugene, OR 97402
S U R E
— LASER LIGHT IS EMITTED FROMTHI
R T U R
E
PRODUCT OF USA
This figure illustrates an example of a laser safety label, which is located on the scanning pod of laser-based Falcon 4400 series units. The label on your unit may appear different or have different informa- tion. Please refer to your unit for specific laser safety requirements.
Complies with 21CFR and Part 15 of FCC rules.
EUR: CE0560 RADIO: BREEZECOM
The Advanced Long Range Laser is rated Class 3R per EN60825-1 and Class II per CFR 1040.
FCC: M52PCRNZZ-00
Models with the Linear Imager are rated LED Class 1 per IEC 60 825-1:2001, only.
NRTL
P A
T :
N263
Advisory Statement
Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous visible or invisible laser light exposure.
Regulatory Statements
Radio Frequency Interference
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter- ference at his or her own expense. Canadian Compliance Statement
This Class A Digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est confirme à la norme NMB-003 du Canada.
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the PSC website at www.psc.com

International Caution Statements for CLASS 11, 22, 3R3, II4, and IIA5 Laser Devices
PSC scanners are certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC/EN 60825-1:1998-2001.
Class 1, 2, 3R, Class II, and IIA products are not considered to be hazardous. The scanner contains internally a Vis- ible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations. The scanner is designed so that there is no human access to harmful laser light during normal operation, user main- tenance or during prescribed service operations.
Ce scanneurs du PSC sont certifié conforme à la norme DHHS/CDRH 21CFR sous-chapitre J et à la norme IEC/ EN 60825-1:1998-2001.
Les produits de class 1, 2, 3R, class II, et de IIA ne sont pas considérés dangereux. Le scanneur contient une diode laser visible (VLD) dont les émissions ne dépassent pas les limites prescrites dans les normes précitées. Le scanneur est conçu de façon à ce qu’il ne soit pas possible d’accéder à la lumière laser pendant l’utilisation normale, l’entretien par l’utilisateur et les fonctions de maintenance prescrites.
ATTENTION Si, quand la fonction de balayage est lancée, le diagramme de balayage est constitué d’un seul point, cesser d’utiliser le scanneur et le retourner à PSC.

Dieser Scanner ist den in den Vereinigten Staaten geltenden Vorschriften des DHHS/CDRH 21 CFR Subchapter J und den Vorschriften der IEC/EN 60825-1:1998-2001 entsprechend bescheinigt.
Produkte der Klasse 1, 2, 3R, Klasse II oder der IIA sind als ungefährlich eingestuft. Im Inneren des Scanners befin- det sich eine VLD (Visible Laser Diode), deren Ausstrahlung die in den oben genannten Vorschriften angeführten Höchstgrenzen nicht überschreitet. Die Konstruktion des Scanners garantiert, daß bei normalem Betrieb, bei War- tung durch den Benutzer oder im Laufe planmäßiger Wartungsarbeiten kein Zugang zu schädlichem Laserlicht besteht.
È stato certificato che questo scanner si conforma ai requisiti della sezione J della normativa DHHS/CDRH 21CFR, e anche ai requisiti di IEC/EN 60825-1:1998-2001.
I prodotti di Classe 1, 2, 3R, Classe II, o IIA non sono considerati pericolosi. Lo scanner contiene al suo interno un Visible Laser Diode (VLD), diodo laser visibile, le cui emissioni non eccedono i limiti stabiliti dalle normative sun- nominate. Lo scanner è progettato in modo che non ci sia alcun accesso alla luce dannosa del laser nel corso di uso normale, di manutenzione da parte dell’utente o durante la manutenzione periodica stabilita.

International Caution Statements for CLASS 1, 2, 3R, II, and IIA Laser Devices
Denne scanner opfylder de amerikanske krav stillet i "DHHS/CDRH 21CFR Subchapter J" og opfylder også de krav, der stilles i IEC/EN 60825-1:1998-2001.
Klasse 1, 2, 3R, klasse II eller klasse IIA produkter anses for at være sikre. Scanneren indeholder en Visible Laser Diode (VLD), der ikke overskrider maksimumgrænserne, som beskrevet i ovenstående reglement. Scanneren er konstrueret, så der ikke er nogen menneskelig kontakt medskadelige niveauer af laserbestråling under normal brug, normal vedligeholdelse eller under foreskrevet servicering.
ADVARSEL Hvis scanningmønsteret er et enkelt punkt, når triggeren indtrykkes, skal betjening ophøre og scanneren returneres til PSC.
ADVARSEL Forsøg ikke at åbne eller reparere komponenter i det optiske hulrum. Uautoriseret åbning eller reparation af komponenter i det optiske hulrum kan være en overtrædelse af lasersikkerhedsregulativer. Det optiske system må udelukkende repareres as PSC.
ADVARSEL Anvendelse af optiske systemer med scanneren øger risikoen for øjenskader. Optiske instruments omfatter kik- kerter, mikroskoper og lupper. Det omfatter ikke anvendelse af almindelige briller.
Deze scanner is in de V.S. goedgekeurd en voldoet aan de vereisten van DHHS/CDRH 21CFR Subchapter J een aan de vereisten van IEC/EN 60825-1:1998-2001.
Producten van klasse 1 ,2, 3R, klasse II en IIA worden niet geacht gevaarlijk te zijn.
De scanner bevat een inwendige Visible Laser Diode (VLD) waarvan de emissies de maximumgrenzen van boven- staande reglementen niet overschrijden.
De scanner is zo ontworpen dat men bij normaal gebruik, onderhoud of tijdens het uitvoeren van de voorge- schreven onderhoudswerkzaamheden niet aan schadelijke niveaus wordt blootgesteld.
Denna scanner uppfyller de amerikanska kraven DHHS/CDRH 21CFR Subchapter J samt kraven i IEC/EN 60825-1:1998-2001.
Produkter i Klass 1, 2, 3R, Klass II och IIA anses ej farliga. Scannern är utrustad med en intern, synlig laserdiod (Visible Laser Diode - VLD) vars emission inte överstiger max. värdena i ova stående säkerhetsföreskrifter. Scannern har konstruerats så att personer vid normal användning, bruksunderhåll och föreskriven service inte utsätts för skadlig laserstrålning.
VAR FÖRSIKTIG Om scanningsmönstret är en enda punkt när du trycker på avtryckaren, ska du avbryta användningen och ta scan- nerna tillbaka till PSC.

VAR FÖRSIKTIG Försök inte öppna eller reparera komponenter i den optiska kamaren. Om icke auktoriserad personal öppnar eller reparerar delar i den optiska kammaren, kan detta strida mot säkerhetsföreskrifterna för laserutrustning. Det optiska systemet får endast repareras på fabriken.
VAR FÖRSIKTIG Användning av optiska system med scannern ökar risken för ögoskada. Optiska instrument inkluderar kikare, mik- roskop och förstoingsglas, men inte användarens glasögon.
Tämä tutkain on hyväksytty Yhdysvalloissa vastaamaan DHHS/CDRH 21CFR Subchapter J luokka 60825- 1:1998-2001 IEC/EN-vaatimuksia.
Luokka 1, 2, 3R, Luokka II tai IIAtuotteiden ei katsota olevan vaarallisia. Tutkain sisältää sisäisen näkyvän laserdio- din (Visible Laser Diode (VLD), jonka päästöt eivät ylitä yllä olevien säädösten asettamia maksimirajoja. Tutkain on suunniteltu siten, etteivät ihmiset altistu vaaralliselle lasersäteilylle normaalikäytön, käyttäjän suorittaman huol- lon tai ohjeiden mukaisten huoltotoimenpiteiden aikana.
VAROITUS Jos skannauskuva on yksittäinen piste laukaisinta painettaessa, keskeytä käyttö ja palauta tutkain PSC:lle.
VAROITUS Älä yritä avata tai muuten huoltaa mitään rakenneosia optisessa osassa. Valtuuttamattoman henkilöstön suoritta- man optisen osan avauksen tai huoltotoimen voidaan katsoa olevan rikkomus lasersuojaohjeita vastaan. Optisen järjestelmän saa korjata ainoastaan tehtaalla.
VAROITUS Mikäli optisia järjestelmiä käytetään tutkainmen kanssa, silmille aiheutuva vaara lisääntyy. Optiset kojeet käsittävät kiikarit, mikroskoopit ja suurennuslasit. Käyttäjän silmälasit eivät kuulu tähän ryhmään.
Denne skanneren er godkjent i USA i samsvar med retningslinjene for DHHS/CDRH 21CFR, avsnitt J, og til IEC/EN 60825-1:1998-2001.
Produkter i klasse 1 2, 3R, klasse II eller IIA ansees ikke som helsefarlige. Skanneren inneholder en innvendig, syn- lig laserdiode (VLD, Visible Laser Diode), som ikke overskrider maksimalgrensene som er fastsatt i retningslinjene ovenfor. Skanneren er konstruert, slik at personer ikke utsettes for farlige doser med laserstråler ved normal drift, brukers vedlikehold eller ved foreskrevet service.
OBS! Hvis skanningsmønsteret består av én enkel prikk når utløseren trykkes inn, skal driften stanses, og skanneren settes tilbake til PSC.
OBS! Prøv ikke å åpne eller på noen måte utføre service på noen av delene i det optiske kammeret. Ved å åpne eller utføre service på noen av delene i det optiske kammeret av uautorisert personell, kan krenke forskriftene for lasersikkerhet. Optikksystemet skal bare repareres på fabrikken.
OBS! Bruk av optiske systemer med skanneren kan innebære høyere fare for øynene. Optiske instrumenter innbefatter, kikkerter, mikroskop og forstørrelsesglass. Dette omfatter ikke briller som brukeren har på seg.

International Caution Statements for CLASS 1, 2, 3R, II, and IIA Laser Devices
Este scanner foi certificado nos EUA para atender os requisitos do subcapítulo J do DHHS/CDRH 21 CFR e os requisitos do IEC/EN 60825-1:1998-2001.
Os produtos da Classe 1, 2, 3R, Classe II ou IIA não são considerados perigosos. O scanner contém internamente um Diodo de Laser Visível (VLD - Visible Laser Diode) cujas emissões não ultrapassam os limites definidos nos regulamentos mencionados acima. O scanner foi projetado de maneira que não exista acesso humano à luz de laser nociva durante a operação normal, manutenção pelo usuário ou durante as operações recomendadas de serviço.
CUIDADO Se ao pressionar o gatilho a luz do laser for um único ponto, interrompa a operação e devolva o scanner à PSC.
CUIDADO Não tente abrir ou consertar qualquer componente da cavidade óptica. A abertura ou manutenção de qualquer peça da cavidade óptica por pessoal não autorizado pode infringir os regulamentos de segurança do laser. O sistema óptico só deve ser reparado na fábrica.
CUIDADO O uso de instrumentos ópticos com o scanner aumenta o risco para a visão. Incluem-se entre os instrumentos ópti- cos os binóculos, microscópios e lentes de aumento. Não se incluem os óculos usados pelo usuário.
Este escáner está certificado en los EE.UU. porque reúne los requisitos DHHS/CDRH 21CFR Sección J y los req- uisitos de IEC/EN 60825-1:1998-2001.
Los productos de Clase 1, 2, 3R, Clase II, o IIA no se consideran como peligrosos. El escáner tiene en su interior un Diodo Láser Visible (VLD) cuyas emisiones no exceden los límites máximos fijados en los reglamentos menciona- dos anteriormente. El escáner está diseñado de modo que las personas no tengan acceso a la luz láser peligrosa durante la operación normal, el mantenimiento por parte del usuario o durante las operaciones de servicio prescri- tas.




International Caution Statements for CLASS 1, 2, 3R, II, and IIA Laser Devices


DECLARATION OF CONFORMITY PSC hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and Standards:
Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC

This equipment is in compliance with the essential requirements & other relevant provisions of Directive 1999/5/ EC. Deze apparatuur voldoet aan de essentiële vereisten en andere relevante voorzieningen van EU-richtlijn 1999/5/ EC. Tämä laite noudattaa direktiivin 1999/5/EC keskeisiä vaatimuksia ja sen muita olennaisia määräyksiä. Cet équipement répond aux exigences et provisions de la Directive 1999/5/EC. Diese Geräte entsprechen den Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EC. Questa apparecchiatura rispetta i requisiti essenziali e le altre clausole rilevanti della Direttiva 1999/5/CE. Dette utstyret er i samsvar med de grunnleggende kravene og andre relevante forskrifter i 1999/5/EC-direktivet. Este equipamento está de acordo com os requisitos essenciais e outras provisões relevantes da Diretiva 1999/5/ EC. Este equipo cumple con los requisitos esenciales y otras provisiones relevantes de la Directiva 1999/5/EC. Denna utrustning uppfyller de väsentliga kraven och andra relevanta förordningar i Direktiv 1999/5/EC. Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-direktiv 1999/5/EF Þetta taeki er samkvaemnt grunnkröfum og öðrum viðeigandi ákvaðum Tilskipunar 1999/5/CE.
Brad West Vice President Quality and Process Management PSC, Inc. 959 Terry Street Eugene, OR 97402 U.S.A.
Peter Lomax Vice President Europe, Middle East & Africa PSC Bar Code Ltd. Axis 3, Rhodes Way Watford Hertfordshire WD24 4TR UK
Standards

Asia Pacific PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Fax: [852]-2-521-0291
Italy PSC S.p.A. Vimercate (MI), Italy Telephone: [39] (0) 39/62903.1 Fax: [39] (0) 39/6859496
Australia PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61] 0 (2) 9878 8999 Fax: [61] 0 (2) 9878 8688
Japan PSC Japan K.K. Shinagawa-ku, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656
France PSC S.A.R.L. LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.44
Latin America PSC S.A., INC. Miami, Florida, USA Telephone: (305) 591-3222 Fax: (305) 591-3007
Germany PSC GmbH Darmstadt, Germany Telephone: 49 (0) 61 51/93 58-0 Fax: 49 (0) 61 51/93 58 58
United Kingdom PSC Bar Code Ltd. Watford, England Telephone: 44 (0) 1923 809500 Fax: 44 (0) 1923 809 505
PSC Inc. 959 Terry Street Eugene, OR Telephone: (541) 683-5700 Fax: (541) 345-7140
©2006 PSC INC. R44-2536 (Rev C) 07/06
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The Falcon does not turn on. | The battery pack is not installed properly. | Ensure the battery is installed properly. | p.45 |
| The Falcon does not turn on. | The battery is not fully charged. | Insert the Falcon in dock and begin charging. The bat- tery pack backup battery and require 24 hours to fully charge at first use, and 4 hours thereafter. | p.45 |
| The Falcon does not turn on. | System failure. | Perform a Hard Reset or a Clean Boot. Refer to Reset- ting the Falcon starting on page 38. | p.45 |
| Rechargeable battery pack did not charge. | Battery failure. | Replace the battery. If the Falcon terminal still does not operate, try a Hard Reset then a Clean Boot; refer to Resetting the Falcon starting on page 38. | p.45 |
| Rechargeable battery pack did not charge. | The Falcon was removed from the dock while battery was charging. | Insert the Falcon in dock and begin charging. The bat- tery pack and backup battery require 4 hours to fully charge. | p.45 |
| Characters are not visible on the display. | The Falcon is not powered on. | Press <POWER>. | p.45 |
| Characters are not visible on the display. | The ambient room light is too dark or low. | Turn on the backlight. Refer to the PRG. | p.45 |
| No sound is audible. | Volume setting is low or turned off. | Adjust the sound volume by going to the Volume icon on the Task bar at the top of the screen. | p.45 |
| No sound is audible. | The expected sound is not con- figured in the software. | Ensure that sounds are enabled by tapping > Settings > Personal > Sounds & Notifications, or > Settings > System > Decoding for sounds related to bar code scanning. OR Scan the appropriate bar code from the PRG. | p.45 |
| The Falcon turns itself off. | The Falcon is inactive. | The Falcon turns off after a period of inactivity. You can set duration from one to 30 minutes. Refer to the PRG to modify the default settings. | p.45 |
| The Falcon will not accept input from the stylus or the keypad. | A software application is “hung.” | Tap > Settings > System > Memory > Running Programs. Select the problematic pro- gram(s) and tap Stop, or Stop All to stop all running programs. | p.45 |
| The Falcon will not accept input from the stylus or the keypad. | System failure. | Perform a Hard Reset or a Clean Boot. Refer to Reset- ting the Falcon starting on page 38. | p.45 |