Faber Range Hood Remote Blower

16 pages·1.2 MB·Blower·PDF·ENDEFRITNLJA
Faber Range Hood Remote Blower
Table of Contents 5 sections warning · CHARACTERISTICS · INSTALLATION · USE · … ShowHide
Page 1 of the Faber Range Hood Remote Blower user manual — Remote Blower
Page 1 · click to enlarge
Page 1

Concept

Faber Range Hood Remote Blower — Concept diagram (page 1)
Fig. 1 · Concept

Remote Blower

Instruction Manual

READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future reference and for local electrical inspectors’ use.

Page 2 of the Faber Range Hood Remote Blower user manual — CHARACTERISTICS 5
Page 2 · click to enlarge
Page 2

CONTENTS

CHARACTERISTICS 5

INSTALLATION 8

USE 13

MAINTENANCE 14

Page 3 of the Faber Range Hood Remote Blower user manual — ELECTRICAL REQUIREMENTS
Page 3 · click to enlarge
Page 3

READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD

READ AND SAVE THESE INSTRUCTIONS WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè). Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT. NEVER PICK UP A FLAMING PAN - You may be burned. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. Use an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire department is being called. 4. You can fight the fire with your back to an exit.

WARRANTY & SERVICE

This rangehood carries a limited warranty against manufacturer’s defects. To obtain warranty service, contact the dealer from whom you purchased the rangehood, or the local Faber distributor. If you cannot identify a local Faber distributor, contact Faber USA at (508) 358-5353 for the name of a distributor in your area.

USE AND CARE INFORMATION

This rangehood system is designed to remove smoke, cooking vapors and odors from the cooktop area. This unit also has several features to insure operator safety.

VENTING REQUIREMENTS Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof. The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap. Flexible ductwork is not recommended. If it is used, each foot of flexible ductwork used is equivalent to two feet of straight metal ductwork when calculating the ductrun length. Thus, a flexible elbow equals two standard elbows.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. For best results, remote blowers should transition to 10" round duct as soon as possible. If small ducting is used, it should be transitioned to 9 or 10" round as soon as possible. WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

  • Venting system MUST terminate outside the home.
  • DO NOT terminate the ductwork in an attic or other enclosed space.
  • DO NOT use 4" laundry-type wall caps.
  • Flexible-type ductwork is not recommended.
  • DO NOT obstruct the flow of combustion and ventilation air.
  • Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/ rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park Quincy, Massachusetts 02269

Page 4 of the Faber Range Hood Remote Blower user manual — warning
Page 4 · click to enlarge
Page 4

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever necessary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

SUITABLE FOR USE WITH SOLID STATE SPEED CONTROLS. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

  • Electrical ground is required on this rangehood.
  • If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.
  • DO NOT ground to a gas pipe.
  • DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.
  • Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.
  • Failure to follow electrical requirements may result in a fire.
Page 5 of the Faber Range Hood Remote Blower user manual — Dimensions
Page 5 · click to enlarge
Page 5

CHARACTERISTICS

Components

Faber Range Hood Remote Blower — Components diagram (page 5)
Fig. 2 · Components

Q.ty 1 1 Hood Body, complete with: Blower, Filters, Controls

A 10 Screws 3,5 x 16

Faber Range Hood Remote Blower — Components diagram (page 5)
Fig. 3 · Components

C 4 Screws 5 x 70

D 4 Wall Plugs ø 10

E 2 Screwsfor wall plugs ø 5

F 2 Wall Plugs ø 5

G 4 Grub screws

Dimensions

Faber Range Hood Remote Blower — Dimensions diagram (page 5)
Fig. 4 · Dimensions
Page 6 of the Faber Range Hood Remote Blower user manual — Dimensional chart - Hood
Page 6 · click to enlarge
Page 6

Dimensional chart - Hood

Faber Range Hood Remote Blower — Dimensional chart - Hood diagram (page 6)
Fig. 5 · Dimensional chart - Hood
Page 7 of the Faber Range Hood Remote Blower user manual — Dimensional chart - LIGHT
Page 7 · click to enlarge
Page 7

Dimensional chart - LIGHT

Faber Range Hood Remote Blower — Dimensional chart - LIGHT diagram (page 7)
Fig. 6 · Dimensional chart - LIGHT
Page 8 of the Faber Range Hood Remote Blower user manual — CALCULATE THE DUCTRUN LENGTH
Page 8 · click to enlarge
Page 8

INSTALLATION

The hood can be installed in the following ways: top air outlet, bottom air outlet, rear air outlet. Once the desired configuration has been chosen (see the diagrams below) it will be necessary to provide an opening in the wall where to house the built-in hood body case. Besides the air ducting pipes, basing on the chosen configuration, the hood has to be electrically connected, and an additional connection raceway between the hood installation area and the lighting area has to be provided.

HOOD INSTALLATION SCHEME

RECESSED HOUSING LOWER BORDER SHALL BE INSTALLED AT THE MINIMUM DISTANCE OF 7-3/32 IN. ABOVE THE COOKING SURFACE.

  • Basing on the following scheme prepare the opening H for housing the built-in hood body case. In case of the bottom air outlet configuration consider that the holes for electrical connection have to be made up on the left side (position U).
  • Concerning the ductrun consider the figures in the following scheme bearing in mind that the rear hole P serves only for the rear air outlet-configuration.
Faber Range Hood Remote Blower — HOOD INSTALLATION SCHEME diagram (page 8)
Fig. 7
Faber Range Hood Remote Blower — HOOD INSTALLATION SCHEME diagram (page 8)
Fig. 8

CALCULATE THE DUCTRUN LENGTH

The ductwork length should not exceed 35 equivalent feet for 3 1/4" X 10" duct, or 55 equivalent feet for 9" or 10" round duct. Calculate the length of the ductwork by adding the equivalent feet listed in FIGURE 1 for each piece of duct in the complete system. An example is given in FIGURE 2. For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. Round duct is recommended instead of rectangular duct especially if elbows are needed. For internal blower models, rectangular duct should be transitioned to 9" round as soon as possible.

45° Elbow 5.0 feet 90° Elbow 7.0 feet 90° Flat Elbow 12.0 feet Wall Cap 0.0 feet FIGURE 1

9 Feet Straight Duct 9.0 feet 2 - 90° Elbows 14.0 feet Wall Cap 0.0 feet Total System 23.0 feet FIGURE 2

Page 9 of the Faber Range Hood Remote Blower user manual — LIGHTING UNIT INSTALLATION SCHEME
Page 9 · click to enlarge
Page 9

LIGHTING UNIT INSTALLATION SCHEME

LIGHTING UNIT LOWER BORDER SHALL BE INSTALLED AT THE MINIMUM DISTANCE OF 34 9/16 IN. ABOVE THE COOKING SURFACE.

With the aid of the drilling template provided mark the necessary holes and drill them.

Faber Range Hood Remote Blower — LIGHTING UNIT INSTALLATION SCHEME diagram (page 9)
Fig. 9
Faber Range Hood Remote Blower — LIGHTING UNIT INSTALLATION SCHEME diagram (page 9)
Fig. 10

The hood is manufactured with the air outlet at the top.

  • Fit the flange with non-return valve onto the air outlet position of the built-in hood body case.
  • In case of the bottom air outlet configuration turn the built-in hood body case 180° before fixing it to the wall.
Page 10 of the Faber Range Hood Remote Blower user manual — FIXING INTO THE WOODEN WALL
Page 10 · click to enlarge
Page 10

REAR AIR OUTLET CONFIGURATION

  • Remove the suction panel by unfastening the 8 screws around the frame.
  • Remove the metal grease filters.
  • Remove the metal profile fixed to the flange by unfastening the 5 screws.
  • Fit the air outlet plug into the top air outlet.
  • Remove the rear air outlet plug .
  • Fit the rear air outlet flange in place of the plug

Built-in hood body case installation

FIXING INTO THE BRICK WALL

  • With the aid of pliers bend the lateral metal tongues of the built-in case.
  • It is necessary to wall the built-in hood body case inside the hollow in the wall paying attention that the external edge of the built-in case adheres perfectly to the wall. It is necessary that the built-in case is precisely levelled both horizontally and vertically, and that the air outlet flange is correctly placed inside the ductrun.

BEFORE INSTALLING THE HOOD IT WILL BE NECESSARY TO WAIT UNTILL THE BUILT-IN HOOD BODY CASE WALLING PROCESS IS COMPLETELY TERMINATED.

FIXING INTO THE WOODEN WALL

  • Insert the built-in hood body case inside the wall paying attention that the built-in case is precisely levelled both horizontally and vertically.
  • Fix the built-in case to the wall using the 10 screws A (3,5x16) provided.
Page 11 of the Faber Range Hood Remote Blower user manual — Hood body installation
Page 11 · click to enlarge
Page 11

Hood body installation

Faber Range Hood Remote Blower — Hood body installation diagram (page 11)
Fig. 11 · Hood body installation
  • In case of the bottom air outlet configuration the hood body has to be turned 180°.
  • Remove the top cover of the terminal box by unfastening the two screws fixing it to the hood casing.
  • With the aid of pliers brake through a hole inside the terminal box providing thus for a passage of the electrical connection for the lighting unit.
  • Place the hood body inside the built-in case paying attention that the screws of the built-in case fall to the gaps of the hood body.
  • Once the screws have reached the gaps it is necessary to fasten them in order to definitively fix the hood body inside the built-in case.
Faber Range Hood Remote Blower — Hood body installation diagram (page 11)
Fig. 12 · Hood body installation
  • It is necessary to make sure that the hood body air outlet is correctly in its’ position inside the air outlet of the builtin case.
Page 12 of the Faber Range Hood Remote Blower user manual — Lighting unit installation
Page 12 · click to enlarge
Page 12

Lighting unit installation

Faber Range Hood Remote Blower — Lighting unit installation diagram (page 12)
Fig. 13 · Lighting unit installation
  • Provide for passage of the electrical connection wires with the hood body.
  • Slide the top cover downwards, unfastening the two side screws and taking care not to scratch the tubular support members.
  • Insert the 4 plugs D into the earlier drilled holes.
  • Decide the height of the light; loosen the grub screws on the outer columns to allow the light to slide up and down. Take care not to scratch the columns when sliding.
  • Fasten the light to the ceiling using 4 screws C .
  • Fix the two support arm connection bushes to the wall..
Faber Range Hood Remote Blower — Lighting unit installation diagram (page 12)
Fig. 14 · Lighting unit installation
  • Make electrical connection:
  • Connect the red wire in the Light-unit with the red lead in the hood using a twist-on connector; connect the purple wire in the Light-unit with the purple lead in the hood using a twist-on connector.
  • Connect the green ground wire to the unused, green ground screw.
  • Replace the top cover, fixing it in place with the two side screws.
Faber Range Hood Remote Blower — Lighting unit installation diagram (page 12)
Fig. 15 · Lighting unit installation
  • Screw the support arms into their housings.
  • Hook them to the connection bushes and lock them in position with the grub screws provided.
  • Close the bush using the masking plug provided
Show 4 more labels / short text on this page
· · ·
Page 13 of the Faber Range Hood Remote Blower user manual — Electrical connection
Page 13 · click to enlarge
Page 13

Electrical connection

Faber Range Hood Remote Blower — Electrical connection diagram (page 13)
Fig. 16 · Electrical connection
  • ELECTRICAL SHOCK HAZARD
  • Disconnect power before making electrical connctions.
  • Connect ground wire to green ground screw in terminal box.

  • Connect the red wire of the Light cable with the red lead in the hood using a twist-on connector; connect the purple wire of the Light cable with the purple lead in the hood using a twist-on connector.
  • Connect the blue blower wire with the blue lead in the hood using a twiston connector; connect the brown blower wire with the brown lead in the hood using a twist-on connector.
  • Connect the ligth unit to the ground using one of the following two alternative ways: aConnect the domestic green ground wire under the unused green ground
Faber Range Hood Remote Blower — Electrical connection diagram (page 13)
Fig. 17 · Electrical connection

screw belonging to the light unit wiring box using a listed conduit connector. b- Connect one end of the green ground wire (max lenght 10 yards using

  • 14 awg wire) under the unused green ground screw belonging to the light unit wiring box and the other end under the unused green ground screw belonging to the range hood wiring box.
  • Connect the green ground wire (from exterior blower and from power supply cable) under the unused green ground screw.
  • Tighten strain relief screws.
  • Connect the white wire of the power supply conduit with the white lead in the hood using a twist-on connector; connect the black wire of the power supply conduit with the black lead in the hood using a twist-on connector.
  • Place the suction panel so that the connection flat wiring for the hood controls passes through the specific opening in the hood body.
  • Fix the suction panel to the hood body fastening the screws removed earlier.
  • Open the suction cover using the lever provided.
  • Connect the flat connection wiring coming from the hood controls with the connector piece placed close to the terminal box. Only in case of the bottom air outlet configuration remove the protection cover from the connector piece on the opposite side of the terminal box.
  • Fix the terminal box cover again and fasten the 2 screws removed earlier.
  • Replace the metal grease filters in their housings.
  • Close the suction panel.
Faber Range Hood Remote Blower — Electrical connection diagram (page 13)
Fig. 18 · Electrical connection
Show 7 more labels / short text on this page
· · · · · ·
Page 14 of the Faber Range Hood Remote Blower user manual — CLEANING METAL GREASE FILTERS
Page 14 · click to enlarge
Page 14

USE

Control Panel

The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.

LED FUNCTIONS L 0/1 Light Turns lighting on and off.

T1 0/1 Motor Fixed First speed. When pressed for about 2 seconds the motor is switched off. T2 Speed Fixed Second speed. T3 Speed on Third speed.

T4 Speed Fixed Max. speed Flashing Intensive speed. Suitable for the strongest cooking vapours and odours. The function becomes active when the button is pushed for about 2 seconds. After 10 minutes of functioning it turns off automatically. This function can be interrupted by means of pressing any of the buttons. S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered, and the filters need to be washed. The alarm is triggered after 100 working hours. (Reset; check the Maintenance- paragraph) Flashing indicates that the activated charcoal odour filter saturation alarm has been triggered, and the filter has to be replaced; the metal grease filters must also be washed. The activated charcoal odour filter is triggered after 200 working hours. (Activation and Reset; check the Maintenance- paragraph)

MAINTENANCE

Grease filters

CLEANING METAL GREASE FILTERS

  • Alarm signal reset
  • Switch off the lights and extractor motor.
  • Press button T3 for at least 3 seconds, until the leds start to flash.
Faber Range Hood Remote Blower — CLEANING METAL GREASE FILTERS diagram (page 14)
Fig. 19
  • Cleaning the filters
  • Open the suction cover using the lever provided.
  • The filters are washable and must be cleaned when the Led S1 lights up or at least every 2 months of operation, or more frequently for particularly heavy usage.
  • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
  • Wash the filters, taking care not to bend them. Allow them to dry before refitting.
  • When refitting the filters, make sure that the handle is visible on the outside.
  • Close the suction panel.

Page 15 of the Faber Range Hood Remote Blower user manual — Electric Diagram
Page 15 · click to enlarge
Page 15

Lighting

Faber Range Hood Remote Blower — Lighting diagram (page 15)
Fig. 20 · Lighting
  • 20 W halogen light.
  • Extract the lamp from the Support.
  • Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.

Electric Diagram

Faber Range Hood Remote Blower — Electric Diagram diagram (page 15)
Fig. 21 · Electric Diagram
Page 16 of the Faber Range Hood Remote Blower user manual — MAINTENANCE
Page 16 · click to enlarge
Page 16

436002499_02 - 041103

Ask about the Faber Range Hood Remote Blower

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Faber Range Hood Remote Blower

Be the first to ask — other owners or our team will answer.

Original document

Faber Range Hood Remote Blower manual PDF

16 pages·1.2 MB·Blower·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…