Faber Feeling Range Hood

29 pages·891 KB·Indoor Fireplace·PDF·ENDEFRITNLJA
Faber Feeling Range Hood
Table of Contents 62 sections MISTY · CADRA NOVA · SPECTRA NOVA · WHISPER · … ShowHide
Page 1 of the Faber Feeling Range Hood user manual — MISTY
Page 1 · click to enlarge
Page 1

Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501

40 010 527 02 37

Faber Feeling Range Hood — MISTY diagram (page 1)
Fig. 1

installation guide and user manual

MISTY

CADRA NOVA

SPECTRA NOVA

WHISPER

FEELING

SILENCE

room-sealed built-in gas-fireplace · “Log Burner Technology”

Page 3 of the Faber Feeling Range Hood user manual — 2. SAFETY AND GENERAL
Page 3 · click to enlarge
Page 3

- Meets the essential requirements of the European Gas Appliance Directive (GAD) and carries the CE mark.

- Remote Control option on all appliances.

- Air supply and flue-gases go to outside atmosphere through wall or roof. A maximum horizontal extension of 6 meters is possible.

- Room sealed appliance, inlet and outlet are led to the outside using a natural draught concentric pipe system (100 mm/150 mm) (no power fan required). No additional ventilation required.

- Realistic flame and glow effect because of the "Log burner" technology.

Special features:

Widescreen interior: Types Silence and Feeling Roundscreen interior: Type Misty MV100 interior: Type Whisper MV110 interior: Types Spectra Nova and Cadra Nova

This guide is concerning the following types of appliances:

1. INTRODUCTION

2.1 General safety

Building Regulations Document J (as applicable).

BS5871 Part1 BS5440 Parts 1 & 2 BS1251.

It is the law in the UK that all gas appliances, are installed by a competent person in accordance with the Gas Safety (Installation and Use) Regulations (as amended), the relevant British Standards for Installation work, Building Regulations, Codes of Practice and the manufacturers instructions. The installation should also be carried out in accordance with the following where relevant:

Ventilation This appliance is room-sealed and doesn't require purpose provided ventilation.

The pilot and flame sensing device fitted to this fire is also a safety device. If for any reason any part of the pilot assembly is to be replaced the entire assembly including the pilot burner, thermocouple, electrode and injector must be exchanged complete for a pilot assembly from the original manufacturer only.

This appliance does not contain any component manufactured from asbestos or any asbestos related products.

This gas appliance is factory set and shall not be adjusted by the installer.

Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.

2. SAFETY AND GENERAL

INFORMATION

Page 4 of the Faber Feeling Range Hood user manual — 3. INSTALLATION REQUIREMENTS
Page 4 · click to enlarge
Page 4

Safety instructions for the user: see chapter 9.

Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty.

In the Republic of Ireland installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of Practice, the manufacturers instructions and any other rules in force.

Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department.

3.1 Builders opening and surround

Isolate the appliance with a ceramic blanket (25 mm). See also chapter 4: Installation instructions. Preferred choice for insulation is unbound insulation wool (at 1000 °C gives no smell).

Do not place the lintel, surround or marble stone directly onto the appliance. If possible, apply a lintel made of cement or something similar.

Although the appliance is tested for installation without a hearth, the appliance must not stand on combustible materials or carpets. If the appliance is placed on a combustible floor then a fibrelux or similar heatproof board of 12 mm thickness should be placed under it. Any under floor vents or openings within the builders opening should be sealed off.

In a non-combustible fireplace or builders opening. This could be either an existing builders opening or a new made prefab builders opening. For the measurements, see figure 1 and index.

The appliance can be installed in the following situations:

As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance.

Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot.

3. INSTALLATION REQUIREMENTS

Page 5 of the Faber Feeling Range Hood user manual — G
Page 5 · click to enlarge
Page 5

*the points A until C applies a tolerance from: – 0 mm and + 5 mm.

A

C B

D

E

F

Builders opening (mm)FeelingSilenceWhisperSpectra NovaCadra NovaMisty AOpening width*960960780780680710 BOpening height*649649705698798890 COpening depth*385385430430430370 Shelf dimensions (combustible) DMin. height shelf from top frame350350350350350350 EDepth shelf max.150150150150150150 Dimensions (mm) FBox width880880750750650698 GBox depth366366397375375338 HBox height636636714715815879 IFrame width10641064815794694740 JFrame height678678720703803905 KFrame thickness4720163030144 LPosition flue (behind frame)255255257235235196 MPosition flue (from the back side box)111111140140140142

G

K

L M

3.1 Builders opening and surround (continuing)

- Ventilate the space above the appliance (min. 1000 mm2 ).

If the builders' opening is constructed out of non-combustible composition board (Fibrelux) and you install the appliance without a mantel then:

table 1

Page 6 of the Faber Feeling Range Hood user manual — C B
Page 6 · click to enlarge
Page 6

3.2 Flue requirements

- The total horizontal extension. This is the total horizontal flue length where:

- The effective height (this is the real difference in height between the upper side of the appliance and the terminal).

To establish this you will need to calculate:

Determine on the base of the table 2 and 3, depending on the type and terminal position, if the desired situation is possible.

Flue routing; - a horizontal extension with elbows is allowed for a maximum of 6 meters (depending on the type and situation). - vertical max. 12 meters.

Terminal locations, through the wall as well as through the roof. See figure 3.

The minimum effective height of the flue system must be 0.5 or 1 meter, depending on the appliance.

The appliance is of the type C11/C31. The appliance will need to be supplied with the approved flue pipes and terminal, it is not possible to supply your own.

  • each elbow, which is in the horizontal area, counts for 2 meters.
  • each 45-degree bend, which is in the horizontal area, counts for 1 meter.
  • elbows and bends at the transition of horizontal to vertically are not to be counted.
  • the wall mounted terminal counts for 1 meter.

If applicable, in the table is also stated the size of a flue restrictor. This restrictor needs to be fitted in the combustion chamber when placing the appliance ( see chapter 4.2). Normally the smallest flue restrictor is fitted.

Flue restrictor

Page 7 of the Faber Feeling Range Hood user manual — X X X X X X
Page 7 · click to enlarge
Page 7

When calculating on basis of the Roundscreen table nr. 5: Combination not allowed.

When calculating on basis of the MV150 table nr. 4: Combination not allowed.

When calculating on basis of the MV100 table nr. 3: Allowed but without flue restrictor. Remove the flue restrictor!

When calculating on basis of the Widescreen table nr. 2: Combination not allowed.

Vertical Flue lenght H 1 m

Total horizontal extension 6 m

Flue lenght J + L = 0,5 + 0,5 1 m Elbows K + M = 2m + 2m 4 m Terminal 1 m

Calculati0n horizontal extension fig. 2b:

When calculating on basis of the Roundscreen table nr. 5: Allowed but without flue restrictor. Remove the flue restrictor!

When calculating on basis of the MV150 table nr. 4: Allowed but without flue restrictor. Remove the flue restrictor!

When calculating on basis of the MV100 table nr. 3: Allowed but without flue restrictor. Remove the flue restrictor!

When calculating on basis of the Widescreen table nr. 2: It is allowed. Remove the flue restrictor!

Total effective height 2 m

Flue lenght A 1 m Roof mounted terinal 1 m

Measure or calculate effective height (Hvert)

Total horizontal extension 4 m

Flue lenght C + E = 1m + 1m 2 m Elbows D = 2m 2 m

Calculati0n horizontal extension fig. 2a:

H

M L K J I

A

C B

Hvert.

Hvert.

fig. 2b

fig. 2a

D

E

F

G

N

Table Whisper and Spectra Nova with interior MV100 Determine according to the table 3 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.

Table Silence and Feeling with interior Widescreen Determine according to the table 2 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.

* at propane not allowed

1 30/X* 2 30 30 3 45 45 30 4 45 45 30 5 50 50 45 45 30 0 0 6 50 50 45 45 30 0 0 7 60 60 60 50 50 45 8 60 50 9 65 65 60 60 10 65 65 65 11 65 65 12 65

0 1 2 3 4 5 6 0 X

1 0 0 1,5 0 2 30 30 3 45 45 30 30 4 45 45 30 30 30 0 0 5 50 50 45 30 30 30 0 6 50 50 45 30 30 30 0 7 60 60 50 45 45 30 8 60 60 60 50 50 9 65 65 60 60 10 65 65 65 11 65 65 12 65

0 1 2 3 4 5 6 0 X

X

X X X X X X

X X X X X

X X X X X

X X X X X X X X

X X X X

X X X X

X combination not allowed 0 remove flue restrictor

table 2 interior Widescreen

X combination not allowed 0 remove flue restrictor

table 3 interior MV100

Number is size in mm of the flue restrictor

Number is size in mm of the flue restrictor

Show 6 more labels / short text on this page
Example calculation 2 · Example calculation 1 · Effective height · Effective height · Horizontal extension · Horizontal extension
Page 8 of the Faber Feeling Range Hood user manual — X X X X X
Page 8 · click to enlarge
Page 8
Nova wit cording t g an X, a mally the Horizo 0 12 3 4 5 6 0 0,5 1 2 3 4 5 6 7 8 9 10 11 12X X X 0 X 30 40 30 40 40 50 40 50 60 50 60 65 60 65 65 65 XX 0 X 0 30 40 30 40 40 30 30 0 50 40 40 30 0 50 40 40 40 X 50 50 50 X X 60 50 X X X 60 X oundscre cording t g an X, a mally the Horizo 0 12 3 4 5 6 0 0,5 1 1,5 2 3 4 5 6 7 8 9 10 11 12X X X 0 X 30 40 30 40 30 40 40 50 40 50 60 50 60 65 60 65 65 65 XX 0 0 0 X X 0 30 40 30 40 40 30 30 0 50 40 40 30 0 50 40 40 40 X 50 50 50 X X 60 50 X X X 60 X

Table Cadra Nova with interior MV150 Determine according to the table 4 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.

12 X

0,5 X 0 X 1 30 X 2 40 30 3 40 40 30 4 50 40 40 30 5 50 50 40 40 30 30 0 6 50 50 50 40 40 30 7 60 50 50 40 40 8 60 60 50 50 9 60 60 60 10 65 60 65 11 65 65

0 1 2 3 4 5 6 0 X

X

60 X X X X

50 X X X

table 4 interior Cadra Nova

X combination not allowed 0 remove flue restrictor

Number is size in mm of the flue restrictor

3.2.1 Terminal position Verify if the required terminal position meets the local installation regulations regarding disturbance, good functioning and ventilation. (Also see: safety requirements). Note: The terminal must be located so that the outlet is not obstructed. If the flue terminal is located within 2 meters of a footway, path or where people could come into contact with it then a suitable terminal guard must be fitted.

3.2 Flue requirements (continuing)

Terminals located close to shared walkways, footpaths etc. could be subject to legal constraints and this should be pointed out to the customer before installation. If in any doubt about flue location advice should be sought from local building control, or if appliance- related, from the manufacturer including wherever possible a dimensioned sketch.

Effective height · Horizontal extension

Page 9 of the Faber Feeling Range Hood user manual — Table 6
Page 9 · click to enlarge
Page 9

Flue terminal positions

Faber Feeling Range Hood — Flue terminal positions diagram (page 9)
Fig. 2 · Flue terminal positions

Dimension Terminal position Balanced flue room sealed (kW input 7.5 kW expressed in net) Natural draught A Direct below an opening, airbrick, 300 mm opening windows, etc. B Above an opening, airbrick, 300 mm opening window ect. C Horizontally to an opening, airbrick, 300 mm opening window etc. D Below gutters, soil pipes or drain pipes 500 mm E Below eaves 500 mm F Below balconies or car port roof 600 mm G From a vertical drain pipe or soil pipe 300 mm H From an internal or external corner 600 mm I Above ground roof or balcony level 300 mm J From a surface facing the terminal 600 mm K From a terminal facing the terminal 600 mm L From an opening in the carport (e.g. 1200 mm window) into the dwelling M Vertically from a terminal on the same wall 1500 mm N Horizontally from a terminal on the same wall 300 mm P From a vertical structure on the roof 600 mm Q Above intersection with roof 500 mm

Table 6

Page 10 of the Faber Feeling Range Hood user manual — B
Page 10 · click to enlarge
Page 10

3.2.2 Using an existing chimney as air inlet You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function.

Example of how terminal position is measured

Faber Feeling Range Hood — Example of how terminal position is measured diagram (page 10)
Fig. 3 · Example of how terminal position is measured

Requirements: - Any existing chimney used as an air supply must only service this appliance. - A chimney that has previously been used for solid fuel must be swept before use. - The existing chimney needs to be airtight. - The existing chimney needs to have an opening of min. 150 x 150 mm. - The chimney needs to be intact and well looked after. - Use the adjustable roof-mounted-terminal especially made for this, and the chimney connection set. - The minimum distance between two terminals should be at least 450 mm.

4.2 Preparing the appliances Widescreen and Whisper

4.1 Gas connection

1. Open the ashtray door by pushing on the right side for the Silence/Feeling and on the left side for the Whisper. Remove the frame by loosening the screws A behind the door (see fig. 5). Lift and pull forward when you take it away.
5. The gas connection is nut and olive suitable for 8 mm pipe.
4. The connection should be made in 8 mm copper or similar semi flexible tube. (max 1 meter). Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls.
3. A means of isolation must be provide in the supply to facilitate servicing.
2. The complete installation including the meter must be tested for soundness and purged as described in the above code.
1. Installation pipes should be in accordance with BS 6891. Pipe work from the meter to the appliance must be of adequate size.

gas supply routes when fire is fitted in a deep surround

A

C = Through wall - Pipe must be sleeved and sealed to fire

A & B = Behind surround - Sleeve pipe through surround

4. INSTRUCTIONS FOR INSTALLATION

B

Show 5 more labels / short text on this page
inner wall · cavity · outer wall · marble · surround
Page 11 of the Faber Feeling Range Hood user manual — Example of how terminal position is measured
Page 11 · click to enlarge
Page 11
Faber Feeling Range Hood — Example of how terminal position is measured diagram (page 11)
Fig. 4 · Example of how terminal position is measured
3. Remove the glass by removing the glass clamps C (see fig. 7) for instance with a screwdriver. Careful when removing the glass! Wear gloves! Before placing the glass back, be sure that there are no fingerprints on the glass, it is not possible to remove those prints after you burn the appliance or a while (they will be burnt in).

Remove the back panel by loosening the screws B (see fig. 6).

4.2 Preparing the appliances Widescreen and Whisper (continuing)

5. Place the right flue restrictor in the combustion chamber. To determine the right flue restrictor, see chapter 3.
4. Take the box with the log set out of the combustion chamber.

Page 12 of the Faber Feeling Range Hood user manual — Example of how terminal position is measured
Page 12 · click to enlarge
Page 12
Faber Feeling Range Hood — Example of how terminal position is measured diagram (page 12)
Fig. 5 · Example of how terminal position is measured
3. To open the door, remove the screws C (see fig. 11). The door opening is limited; if you need more space then remove the door (lift and pull forward). Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in).
2. Open the ashtray door by pulling down (bottom handle).
1. Remove the door frame. Lift and pull forward (see fig. 10).

4.3 Preparing the appliance Misty (continuing)

5. Place the right flue restrictor in the combustion chamber. To determine the right flue restrictor, see chapter 3.
4. Take the box with the log set out of the combustion chamber.

Page 13 of the Faber Feeling Range Hood user manual — Example of how terminal position is measured
Page 13 · click to enlarge
Page 13

4.4 Preparing the appliances Spectra Nova/Cadra Nova

2. Remove the back panel by loosening the 4 screws B (see fig. 14).
Faber Feeling Range Hood — Example of how terminal position is measured diagram (page 13)
Fig. 6 · Example of how terminal position is measured
1. To open the door, remove the screws A (see fig. 13). Open and remove the door; lift and pull forward. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in).
Faber Feeling Range Hood — Example of how terminal position is measured diagram (page 13)
Fig. 7 · Example of how terminal position is measured

4.4 Preparing the appliances Spectra Nova/Cadra Nova (continuing)

5. Place the right flue restrictor in the combustion chamber. To determine the right flue restrictor, see chapter 3.
4. Take the box with the log set out of the combustion chamber.

Page 14 of the Faber Feeling Range Hood user manual — Example of how terminal position is measured
Page 14 · click to enlarge
Page 14

4.5 Fitting the firebox

7. Place the log set (see placing log set, chapter 4.4).
6. Isolate the firebox with a ceramic blanket (25 mm). Preferred choice for insulation is unbound insulation wool (at 1000 °C gives no smell).
5. If necessary, place the DC convection system (also consult the instruction belonging to the DC construction set).
4. Check if applicable that the safety hatch seals the combustion chamber properly.
3. Assemble the flue system onto the firebox (see chapter 5).

2 Make the gas connection according to the instructions (also see gas connection, chapter 4.1).

1. Position the firebox in the fireplace opening. You can adjust the height with the 4 adjustable feet.

Points of attention for placement: - If possible, first locate the appliance before assembling the flue. - If this is not possible then always use an extendible pipe before connection onto the appliance.

Faber Feeling Range Hood — Example of how terminal position is measured diagram (page 14)
Fig. 8 · Example of how terminal position is measured

4.5 Fitting the firebox (continuing)

10. Misty and widescreen: Fix the back and top or door frame (the back frame first).
9. Before placing the glass; check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in).
8. Spread, the bags of embers (imitation ashes) provide with the appliance over the burner tray. Attention! No embers on the grid end between the logs and the burner tray.

- Widescreen and Whisper; Place the glass in front of the appliance and fix it with the glass clamps. Replace the frame. - Misty, Cadra Nova and Spectra Nova: Place the door and fix it. Check on visual leakages around the door sealing.

Show 7 more labels / short text on this page
safety hatch · ceramic blanket · · ceramic blanket · ceramic blanket · ceramic blanket · ceramic blanket
Page 15 of the Faber Feeling Range Hood user manual — 5. INSTALLATION OF THE FLUE
Page 15 · click to enlarge
Page 15

4.6.1 Placing the log set Widescreen, Whisper, Spectra Nova, Misty and Cadra Nova

4.6 Placing the log set

  • L location on the left side resting on the rear log.
  • R location on the right side resting on the rear log.
  • 1 dimple first log left placed over the burner and resting on the burner tray.
  • 2 dimples placed in the middle over he burner and resting on the burner tray.
  • 3 dimples the right side log placed over the burner and resting on the burner tray.

On the bottom of the logs is a identification:

Never place extra elements of any kind into the combustion chamber. To guarantee good combustion, the log set may only be installed in the way specified by Faber International. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or missing logs.

Faber Feeling Range Hood — 5. INSTALLATION OF THE FLUE diagram (page 15)
Fig. 9
Faber Feeling Range Hood — 5. INSTALLATION OF THE FLUE diagram (page 15)
Fig. 10

5.1 Connections with use of concentric duct material

- The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre.

- To get the exact measure flue length you can use cut down- concentric pipe, wall mounted terminal or roof mounted terminal. To obtain a smoke sealed connection, the inner pipe must be 20 mm longer then the outside pipe.

- Because of expansion or cooling down the concentric pipes can turn loose. It is recommended to fix the spring clip with a self tapping screw at inaccessible places.

- The outside of the pipe can become hot (140 degrees). Stay 50 mm away from wall surface or sealing. Make sure to provide sufficiently heat resistant isolation when going through the wall or roof.

- Make sure the pipes are fixed sufficiently, a wall clamp every 2m, so the weight of the pipes is not resting onto the appliance.

- Make sure you place the pipes in the right direction, the narrow end towards the appliance.

- Make a hole of ø 153 mm for the wall or roof mounted terminal.

- Build the system starting from the appliance on.

5. INSTALLATION OF THE FLUE

UK/IRL UK/IRL

Page 16 of the Faber Feeling Range Hood user manual — UK/IRL UK/IRL
Page 16 · click to enlarge
Page 16

UK/IRL UK/IRL

Requirements: - 300 mm of free space above the appliance; - The chimney only supply’s air to this appliance; - The existing chimney needs to be clean and very well swept; - The existing chimney needs to be airtight; - The existing chimney needs to have an opening of min. 150 x 150 mm.

You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function. Any existing chimney used as an air supply must only service this appliance.

5.2 Connection onto an existing chimney

E

F

D

A

B

Parts needed for this kind of installation: - Chimney connection set part number A9225000 Fig 20 part D - Short roof terminal part number A9266100 Fig 19 part B - Chimney closure plate part number A 9240000 Fig 19 part A - Two stainless steel tubes one 100 mm - length 500 mm and one 150 mm - length 500 mm part number A 9273900 Fig 19 part E and F

4. Place the roof terminal onto the closure plate.
3. Connect the liner onto the roof terminal and fix this with the clamp provided with the chimney connection set.
2. Pull the liner (C) through the chimney.
1. Place the aluminium closure plate (A) onto the chimney. Permanently attach and make airtight.

5.2 Connection onto an existing chimney (continuing)

11. Slide the outside pipe onto the appliance or concentric extension so that you have a air tight connection.
10. If the distance from the flue outlet to the sealing plate is bigger then 300 mm, you have to use a concentric pipe first.
9. Connect the flexible stainless steel liner onto the appliance using the 100mm pipe (F) as adapter.
8. Install the appliance.
7. Slide the pipe (E) 150mm length 500mm into the sealing plate. Slide this pipe so far that you will have enough space later on for assembling the liner.
6. Fix the sealing plate air tight into the builders opening (use the isolation rope from the chimney connection set to make the plate air tight).
5. Fixing the chimney sealing plate (D) and place the 150 mm grommet into the hole of the sealing plate.

UK/IRL UK/IRL

Page 17 of the Faber Feeling Range Hood user manual — UK/IRL UK/IRL
Page 17 · click to enlarge
Page 17

UK/IRL UK/IRL

5.3.1 Installation remote control 1. Connect the mains adapter to the receiver box. The adapter is set to the correct voltage in the factory 4.5V.

5.3 Remote control (if applicable)

2. Slide the receiver box into the holder.

Features: - Manual control will always remain possible. - The remote control is a radio frequency type and has been approved internationally. - The remote control generates a unique safety code every time you activate the transmitter, its similar to those used in a car. - The remote control is easy to install retrospectively.

The radio-frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria, Denmark, Finland and Greece.

The remote control is only meant to regulate the flames, it functions only when the pilot burner is ignited. It is therefore not possible to ignited the appliance with the remote control or to shut-off the pilot- flame.

Faber Feeling Range Hood — UK/IRL UK/IRL diagram (page 17)
Fig. 11
6. Check if you can hear a sound and the motor runs when you push a button on the remote control.
5. The receiver now recognizes the remote control. The remote control now functions.
4. Again push a button on the remote control. The lamp starts flashing and will switch off eventually.
3. Push a button on the remote control. The control lamp on the receiver should now go out.
2. The green control lamp will light up and stay on. Repeat this step if it doesn't.
1. Push the "mod" button on the receiver and hold it for 3 seconds.

Setting the right transmission code The receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the receiver is disconnected from the mains for a longer period.

5. Set the on/off switch on the receiver to "on".
4. Check that there are batteries in the transmitter. See "Replacing batteries", see chapter 10.4.4.
3. Connect the wires to the gas valve (see fig. 22).

UK/IRL UK/IRL

Page 18 of the Faber Feeling Range Hood user manual — C D
Page 18 · click to enlarge
Page 18

UK/IRL UK/IRL

6.2 Functional burner check

6.1. Check pilot ignition

1. Turn knob (B) to max. clockwise. 2. Turn the knob (A) more anticlockwise to the position (large flame). Now it is possible to light the main burner. 3. Turn knob B anticlockwise to max. The main burner should light. Check for gas soundness at all joints with leak detection floud! 4. Check the ignition of the main burner on low and high setting. 5. Turn knob B clockwise till {. The main burner is off. 6. Turn the knob A to {. The pilot should go out.

1. Push in and turn the control knob (A) from { anticlockwise to the setting (small flame). You will hear a tick meaning there is ignition. Hold the knob in and wait for a few seconds while the air is purged. 2. Bring the knob back in the start position and turn the knob several times to the position. Check that the pilot has lit. 3. Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable. 4. Release the knob. The pilot should remain alight.

A B

6. COMMISSIONING (functional checks)

6.4 Check reference pressure

6.3 Functional balanced flue check

After checking the pressure, turn off the appliance. Remove the pressure gauge and close the sealing screw. Re-light the appliance. Turn to max. input and test around the test point D for gas soundness using a suitable leak detection fluid.

The pressure should be checked with the appliance alight and at max input. The setting pressure should be as shown at the technical data page 41.

The appliance is preset to give the correct heat input. No further adjustment is necessary. Fit a pressure gauge at the test point D to check the burner pressure.

1. Set the appliance on max. input. 2. Verify the flame picture, this means no flames against the window, the flame have to come besides the logs, if not check the log layout. 3. Check if the flames are yellow after 10 minutes of operation. If you still have a blue flame or the appliance goes out check: - If the flue pipes are fitted correctly (no leakage). - If the wall mounted terminal is placed with the correct side up. - If the correct flue restrictor is installed.

C D

D C

A B

B A

UK/IRL UK/IRL

Page 19 of the Faber Feeling Range Hood user manual — 8. SERVICING
Page 19 · click to enlarge
Page 19

UK/IRL UK/IRL

7.2.4 Recommend that the appliance should be serviced by a competent person at least once a year.

7.2.3 Hand over these instructions including the user guide to the consumer.

7.2.2 Instruct the customer on the operation of the remote control, including replacement of batteries and how to set the right transmissions code.

7.2.1 Advise the customer how to clean the appliance including the glass.

7.1 Instruct the customer on the full operation of the appliance.

7. HANDING OVER

(final check and customer briefing)

8.1 Routine annual servicing

1. Clean (if necessary): - the pilot system; - the burner; - the combustion chamber; - the glass. 2. Check the log lay and replace the embers (if applicable). 3. Do the functional test as described at page 34. 4. Check the flue system and terminal on damage and soundness (visual inspection).

It is recommended, that the fire is inspected/serviced by a competent person at least once a year.

To ensure safe, efficient operation of the appliance, it is necessary to carry out routine servicing at regular intervals.

8. SERVICING

Page 20 of the Faber Feeling Range Hood user manual — D
Page 20 · click to enlarge
Page 20

8.1.3 Propane conversion For conversion from propane to natural gas, order for a propane burner unit. Please give the serial number from the data plate when you order.

8.1.2 Cleaning the combustion chamber and burner You can clean the combustion chamber with a vacuum cleaner.

8.1.1 Cleaning the glass Depending on the intensity of use, you can get a deposit on the glass. This can be removed with a special ceramic glass cleaner (ceramic cook-top cleaner) as follows:

If the burner is visibly damaged, this can affect the distribution of the flame, if so then replace the burner.

Attention: Before placing the glass: check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in). Place the glass in front of the appliance and fix the glass frame or use the glass clamps.

1. Remove the front and the back. 2. Clean the glass. Handle the glass with clean hands, wear gloves if possible. 3. To fit the glass, proceed in reverse order. Make sure that the log set has been installed correctly before fixing the glass.

8.1.5 Pilot/thermocouple assembly Remove the burner tray as described above. Now you have access to all the pilot and thermocouple parts.

8.1.4 Burner tray assembly 1. Remove the front, glass, log set, grid and burner tray cover. 2. Break the gas supply at the control valve. 3. Unscrew the burner assembly and take them out of the combustion chamber.

A. Pilot assembly B. Burner C. Fixation plate D. Injector E. Gas control F. Receiver

Faber Feeling Range Hood — E F diagram (page 20)
Fig. 12

D

E F

B

A

Page 21 of the Faber Feeling Range Hood user manual — UK/IRL UK/IRL
Page 21 · click to enlarge
Page 21

8.1.6 Gas control block

A Governor B Adjusting screw pilot flame C Inlet pressure test point D Burner pressure test point

C D

D C

B A

A B

8.1.7 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet.

A reading of CO in the room centre should give a rise of less than 9ppm over ambient, peak reading.

A Ratio of CO/CO2 should be less than 0.01 within 30 minutes. (100ppm CO per 1% CO2).

UK/IRL UK/IRL

Page 22 of the Faber Feeling Range Hood user manual — Widescreen Silence en Feeling C11/C31
Page 22 · click to enlarge
Page 22

8.2 LIST OF SPARE PARTS

Touch Latch assembly 28103900 28103900 28103900 x x x

Set of glass clips 20900008 20900008 20900008 x x x

spray for comb. chamb. 09000008

Embers 20900019

Spark electrode 06006600

Thermocouple 37002033

propane 20900154

Pilot burner assemb.

Pilot burner assemb. NG 20900145

Motor (remote control) 37003086

Gas control 37003089

Adapter 20900142

Remote control 20603900

Receiver 20604000

Spark wire 06017300

Log set 20773200 20774500 20772500 20786130 20773700 20773700

Burner propane 20521835 20900167

Burner NG 20521808 20900166

Glass below x 04509600 04509400

Glass 04508200 04508300 04508300 04509000 4509500 04509300

Surround antracite A9271453 A9270053 A9267753 AA9272853 A9274149 A9274249

Whisper Feeling Silence Misty Spectra Cadra Nova Nova Description Company part

Widescreen Silence en Feeling C11/C31

8.3 TECHNICAL DATA

Dimensionssee table 1

Gas connection mm 8 mm nut 18 mm nut and olive. and olive

Remote control Adapter V 4,5 Batteries remote control 2x LR03 1,5 V Alkaline

Gas control GV36 with GV36 without pressure reg. pressure reg.

Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30

Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30

Injector size mm 3x 1,45 3x 1,00 1x 1,30 Reduced input restrictor mm 1,8 1,1

Reference burner pressure mbar 17 22

Gas rate 15 °C / 1013 mbar m3/h 740 231 kg/h 540 g

Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7,5 7,2 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 / 37

Country UK/IRL UK/IRL Category II2H3+ II2H3+

Heat resisting paint

Page 23 of the Faber Feeling Range Hood user manual — MV150 Cadra Nova
Page 23 · click to enlarge
Page 23

Weight incl packing material kg 75 75 Dimensions: see table 1

Gas connection mm 8 mm nut 8 mm nut and olive and olive

Remote control Voltage adapter V 4,5 Batteries 2x LR03 1,5 V Alkaline

Gas control GV36 with GV36 without pressure reg. pressure reg.

Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30

Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30

Injector size mm 2x 1,40 3x 1,00 1x 1,30 Reduced input restrictor mm 1,8 1,1

Reference burner pressure mbar 17 22

Gas rate 15 °C / 1013 mba m3/h 790 231 kg/h 540 g

Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7,5 7,5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30/37

Country UK/IRL UK/IRL Category II2H3+ II2H3+

MV100 Whisper and Spectra Nova

8.3 TECHNICAL DATA

Weight incl. packing material kg 75 75 Dimensions: see table 1

Gas connection mm 8 mm nut 8 mm nut and olive and olive

Remote control Voltage adapter V 4,5 Batteries 2x LR03 1,5 V Alkaline

Gas control GV36 with GV36 without pressure reg. pressure reg

Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30

Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30

Reduced input restrictor mm 1.8 1.1

Injector size mm 3x 1.50 3x 0.90

Reference burner pressure mbar 13 25

Gas rate 15 °C / 1013 mbar m3/h 800 231 kg/h 540 g

Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7.5 7.5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30/37

Country UK/IRL UK/IRL Category II2H3+ II2H3+

MV150 Cadra Nova

8.3 TECHNICAL DATA

Page 24 of the Faber Feeling Range Hood user manual — Roundscreen Misty
Page 24 · click to enlarge
Page 24
Dimensionssee table 1

Gas connection mm 8 mm nut 8 mm nut and olive and olive

Remote control Voltage adapter V 4,5 Batteries 2x LR03 1,5 V Alkaline

Gas control GV36 with GV36 without pressure reg. pressure reg.

Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30

Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30

Reduced input restrictor mm 1,8 1,1

Injector size mm 3x 1,50 3x 0,95

Reference burner pressure mbar 16 25

Gas rate 15 °C / 1013 mbar m3/h 900 231 kg/h 540 g

Model type C11 0f C31 C11 0f C31 Heat input Hi kW 8,5 8,5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 / 37

Country UK/IRL UK/IRL Category II2H3+ II2H3+

Roundscreen Misty

8.3 TECHNICAL DATA

USER GUIDE

UK/IRL UK/IRL UK/IRL

Page 25 of the Faber Feeling Range Hood user manual — 9. SAFETY INSTRUCTIONS FOR THE
Page 25 · click to enlarge
Page 25

9.1 General safety instructions

Switch off the receiver of the remote control if you don’t use the fire for a long time. Do not let children use the remote control without supervision.

Do not place curtains, clothing, laundry, furniture or other flammable materials nearby the appliance. The required minimum distance is 100 cm.

Due to the newness of materials, they may give off a slight smell for a period after initial lighting. This is normal, odours will disperse after a few hours use.

The appliance has been designed for heating purposes. This means that all surfaces, including the glass, can become very warm (over 100 degrees). An exception to this is the lower side of the door and the control buttons.

The fire has a safety device which turns off the gas supply if there is a build up from flue gasses in the combustion room or a temporary gas cut-off. Wait at least 5 minutes before turning the appliance on again. Contact a qualified installer when the appliance goes off regularly.

Do not use the fire with a broken or damaged glass.

These instructions should be read carefully and retained for future reference.

If a gas leak is found or suspected, turn off the gas supply at the meter and contact your installer or gas emergency service.

9. SAFETY INSTRUCTIONS FOR THE

USER

Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot. As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance.

In your own interest and that of safety, all gas appliances must be installed by competent persons. Installation must be in accordance with National Regulations. CORGI registered installers are required to work to recognised standards.

Page 26 of the Faber Feeling Range Hood user manual — A B
Page 26 · click to enlarge
Page 26

10.1 Lighting the fire

With control button A you can light the pilot. With the control button B you can adjust the height of the flames (see fig. 27).

Cadra Nova and Spectra Nova Open by pushing the lip located on the right side in the gap between the ashtray door and the frame (door flaps open).

Misty Open the ashtray door by pulling down (bottom handle with gas damper).

Silence /Feeling /Whisper Open the ashtray door by pushing on the right side for the Silence/Feeling and on the left side for the Whisper.

The control valve is behind the ashtray door.

If the main burner or pilot light are extinguished for any reason, do not attempt to relight the pilot within 5 minutes. Contact a qualified installer when the appliance goes off regularly.

A B

10. CONTROLLING THE APPLIANCE

fig. 27 control unit

10.2 To light

Knob B The { is the OFF position preventing gas entering the main burner if the pilot is lit. The knob should be turned slowly anticlockwise. This allows gas to enter the burner and be ignited by the pilot flame. Once ignition has taken place, the fire may be set to any level between min. and max. by adjusting the control knob B.

Knob A The { is the OFF position preventing any gas from passing through the control valve to either the pilot burner or to the main burner. By pressing the knob in it is possible to turn it anticlockwise. The first function is to turn on the gas to the pilot- this occurs just before reaching the |position (if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner). Once gas is available at the pilot, continued rotation anti-clockwise will cause the piezo igniter to spark. This is accompanied by a click at the valve and should result in the pilot burner igniting. Once the pilot is lit, the control knob should be held pressed in for 10 seconds. In this time the pilot flame will have heated the flame supervision thermocouple sufficiently to operate a hold- on magnet within the valve. Now turn the control knob A to the position. This allows gas to enter control knob B.

6. Adjust flames to the required level.
5. Turn knob B slowly anticlockwise, the fire should then ignite.
4. Turn the control knob A to the position.
3. Release the knob. The pilot should remain alight.
2. Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable.
1. Push in and turn the control knob (A) from { anticlockwise to the setting (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).
Page 27 of the Faber Feeling Range Hood user manual — 10. CONTROLLING THE APPLIANCE
Page 27 · click to enlarge
Page 27

10.4 Remote control version

10.3.1 When the pilot extinguishes Warning! When the pilot extinguishes, for whatever reason, you should wait at least 5 minutes before trying to turn it on again.

10.3 To extinguish

Features: - Manual control will always remain possible. - The remote control is a radio frequency type and had been approved internationally. - The remote control generates a unique safety code every time you activate the transmitter, its similar to those used in a car. - The remote control is easy to install retrospectively.

The remote control is only meant to regulate the flames from off till max., it functions only when the pilot burner is ignited and knob A in (big flame) position. It is therefore not possible to ignite the pilot flame with the remote control or to extinguish the pilot flame. The radio-frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria, Denmark, Finland, and Greece.

Contact a qualified installer when the appliance goes off regularly.

Possible causes of pilot extinguish are: - Operating error. - Interference of the safety device. - Failure in the pilot flame system.

3. To extinguish the pilot turn control knob A to position { , although it is in order lo leave the pilot permanently lit.
2. To disable knob B turn knob A to the position.
1. For the main burner turn the control knob B clockwise to position { .

10.4.2 To extinguish 1. Push (low) till the burner goes out and you can hear the motor clicking.

10.4.1 To light 1. Push in and turn the control knob (A) from { anticlockwise to the setting (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).

3. To extinguish the pilot turn control knob A to position { , although it is in order to leave the pilot permanently lit.
2. To enable the remote control turn knob A to the position.
8. When the fire is not be used for a prolonged period, turn off the pilot (see 10.4.2).
7. You will hear a beep every time the receiver recognises a good signal. (If not, so see 10.4.3, setting the right transmission code).
6. Use (high) and (low) to achieve the desired heating and flame effect.
5. Set the on/off switch on the receiver to "on”.
4. Turn the control knob A to the position.
3. Release the knob. The pilot should remain alight.
2. Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable.

remote control · high flame · low flame

Page 28 of the Faber Feeling Range Hood user manual — AAA
Page 28 · click to enlarge
Page 28

10.4.3 Setting the right transmission code he receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the receiver is disconnected from the mains for a longer period,

7. Check if you can hear a sound and the motor runs when you push a button on the remote control.
6. The receiver now recognizes the remote control. The remote control now functions.
5. Again push a button on the remote control. The lamp starts flashing and will switch off eventually.
4. Push a button on the remote control. The control lamp on the receiver should now go out.
3. The green control lamp will light up and stay on. Repeat this step if it doesn't.
2. Push the "mod" button on the receiver and hold it for 3 seconds.
1. Set the on/off switch on the receiver to "on".

10.4.4 Changing the batteries There is no risk of electric shock as the low voltage supply is similar to that used in torches. Always turn off the appliance before changing batteries.

AAA

AAA

5. It might be possible that you have to set the transmission code after changing the batteries (see 10.4.3).
4. Click the battery clip into the remote control and close the cover.
3. If necessary, remove the old batteries and place the new ones: 2 x LR03 Alkaline long life 1.5 V.
2. Carefully remove the battery clip along the side. Pay attention not to pull the wires.
1. Remove the cover on the back of the remote control.
Show 4 more labels / short text on this page
changing batteries · + · + · Remote control
Page 29 of the Faber Feeling Range Hood user manual — 12. DISPOSAL OF THE PACKAGING
Page 29 · click to enlarge
Page 29

To maintain the finish on the trim wipe with soft damp cloth only. Do not use abrasive cleaners, polish or solvents as these can damage the surface finish.

It is recommended that the fire is inspected/serviced, by a competent person at least once a year.

11. CLEANING AND SERVICE

INSTRUCTIONS

Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities.

Batteries are considered chemical waste. The batteries should be disposed of responsibly and in conformity with government regulations. Remove the batteries before disposing of the remote control.

These materials should be disposed responsibly and in conformity with government regulations.

The appliance packaging is recyclable. The packaging could include the following materials: - cardboard; - CFC-free foam (soft); - wood; - plastic; - paper.

12. DISPOSAL OF THE PACKAGING

AND THE APPLIANCE

UK/IRL UK/IRL UK/IRL UK/IRL

Ask about the Faber Feeling Range Hood

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Faber Feeling Range Hood

Be the first to ask — other owners or our team will answer.

Original document

Faber Feeling Range Hood manual PDF

29 pages·891 KB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…