Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501
40 010 527 02 37

installation guide and user manual
CADRA NOVA
SPECTRA NOVA
WHISPER
FEELING
SILENCE
room-sealed built-in gas-fireplace · “Log Burner Technology”


- Meets the essential requirements of the European Gas Appliance Directive (GAD) and carries the CE mark.
- Remote Control option on all appliances.
- Air supply and flue-gases go to outside atmosphere through wall or roof. A maximum horizontal extension of 6 meters is possible.
- Room sealed appliance, inlet and outlet are led to the outside using a natural draught concentric pipe system (100 mm/150 mm) (no power fan required). No additional ventilation required.
- Realistic flame and glow effect because of the "Log burner" technology.
Special features:
Widescreen interior: Types Silence and Feeling Roundscreen interior: Type Misty MV100 interior: Type Whisper MV110 interior: Types Spectra Nova and Cadra Nova
This guide is concerning the following types of appliances:
2.1 General safety
Building Regulations Document J (as applicable).
BS5871 Part1 BS5440 Parts 1 & 2 BS1251.
It is the law in the UK that all gas appliances, are installed by a competent person in accordance with the Gas Safety (Installation and Use) Regulations (as amended), the relevant British Standards for Installation work, Building Regulations, Codes of Practice and the manufacturers instructions. The installation should also be carried out in accordance with the following where relevant:
Ventilation This appliance is room-sealed and doesn't require purpose provided ventilation.
The pilot and flame sensing device fitted to this fire is also a safety device. If for any reason any part of the pilot assembly is to be replaced the entire assembly including the pilot burner, thermocouple, electrode and injector must be exchanged complete for a pilot assembly from the original manufacturer only.
This appliance does not contain any component manufactured from asbestos or any asbestos related products.
This gas appliance is factory set and shall not be adjusted by the installer.
Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.
INFORMATION

Safety instructions for the user: see chapter 9.
Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty.
In the Republic of Ireland installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of Practice, the manufacturers instructions and any other rules in force.
Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department.
3.1 Builders opening and surround
Isolate the appliance with a ceramic blanket (25 mm). See also chapter 4: Installation instructions. Preferred choice for insulation is unbound insulation wool (at 1000 °C gives no smell).
Do not place the lintel, surround or marble stone directly onto the appliance. If possible, apply a lintel made of cement or something similar.
Although the appliance is tested for installation without a hearth, the appliance must not stand on combustible materials or carpets. If the appliance is placed on a combustible floor then a fibrelux or similar heatproof board of 12 mm thickness should be placed under it. Any under floor vents or openings within the builders opening should be sealed off.
In a non-combustible fireplace or builders opening. This could be either an existing builders opening or a new made prefab builders opening. For the measurements, see figure 1 and index.
The appliance can be installed in the following situations:
As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance.
Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot.

*the points A until C applies a tolerance from: – 0 mm and + 5 mm.
C B
D
E
F
K
L M
3.1 Builders opening and surround (continuing)
- Ventilate the space above the appliance (min. 1000 mm2 ).
If the builders' opening is constructed out of non-combustible composition board (Fibrelux) and you install the appliance without a mantel then:
table 1

3.2 Flue requirements
- The total horizontal extension. This is the total horizontal flue length where:
- The effective height (this is the real difference in height between the upper side of the appliance and the terminal).
To establish this you will need to calculate:
Determine on the base of the table 2 and 3, depending on the type and terminal position, if the desired situation is possible.
Flue routing; - a horizontal extension with elbows is allowed for a maximum of 6 meters (depending on the type and situation). - vertical max. 12 meters.
Terminal locations, through the wall as well as through the roof. See figure 3.
The minimum effective height of the flue system must be 0.5 or 1 meter, depending on the appliance.
The appliance is of the type C11/C31. The appliance will need to be supplied with the approved flue pipes and terminal, it is not possible to supply your own.
If applicable, in the table is also stated the size of a flue restrictor. This restrictor needs to be fitted in the combustion chamber when placing the appliance ( see chapter 4.2). Normally the smallest flue restrictor is fitted.
Flue restrictor

When calculating on basis of the Roundscreen table nr. 5: Combination not allowed.
When calculating on basis of the MV150 table nr. 4: Combination not allowed.
When calculating on basis of the MV100 table nr. 3: Allowed but without flue restrictor. Remove the flue restrictor!
When calculating on basis of the Widescreen table nr. 2: Combination not allowed.
Vertical Flue lenght H 1 m
Total horizontal extension 6 m
Flue lenght J + L = 0,5 + 0,5 1 m Elbows K + M = 2m + 2m 4 m Terminal 1 m
Calculati0n horizontal extension fig. 2b:
When calculating on basis of the Roundscreen table nr. 5: Allowed but without flue restrictor. Remove the flue restrictor!
When calculating on basis of the MV150 table nr. 4: Allowed but without flue restrictor. Remove the flue restrictor!
When calculating on basis of the MV100 table nr. 3: Allowed but without flue restrictor. Remove the flue restrictor!
When calculating on basis of the Widescreen table nr. 2: It is allowed. Remove the flue restrictor!
Total effective height 2 m
Flue lenght A 1 m Roof mounted terinal 1 m
Measure or calculate effective height (Hvert)
Total horizontal extension 4 m
Flue lenght C + E = 1m + 1m 2 m Elbows D = 2m 2 m
Calculati0n horizontal extension fig. 2a:
M L K J I
A
C B
Hvert.
Hvert.
fig. 2b
fig. 2a
E
F
G
N
Table Whisper and Spectra Nova with interior MV100 Determine according to the table 3 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.
Table Silence and Feeling with interior Widescreen Determine according to the table 2 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.
* at propane not allowed
1 30/X* 2 30 30 3 45 45 30 4 45 45 30 5 50 50 45 45 30 0 0 6 50 50 45 45 30 0 0 7 60 60 60 50 50 45 8 60 50 9 65 65 60 60 10 65 65 65 11 65 65 12 65
0 1 2 3 4 5 6 0 X
1 0 0 1,5 0 2 30 30 3 45 45 30 30 4 45 45 30 30 30 0 0 5 50 50 45 30 30 30 0 6 50 50 45 30 30 30 0 7 60 60 50 45 45 30 8 60 60 60 50 50 9 65 65 60 60 10 65 65 65 11 65 65 12 65
0 1 2 3 4 5 6 0 X
X X X X X X
X X X X X
X X X X X
X X X X X X X X
X X X X
X X X X
X combination not allowed 0 remove flue restrictor
table 2 interior Widescreen
X combination not allowed 0 remove flue restrictor
table 3 interior MV100
Number is size in mm of the flue restrictor
Number is size in mm of the flue restrictor

Table Cadra Nova with interior MV150 Determine according to the table 4 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.
0,5 X 0 X 1 30 X 2 40 30 3 40 40 30 4 50 40 40 30 5 50 50 40 40 30 30 0 6 50 50 50 40 40 30 7 60 50 50 40 40 8 60 60 50 50 9 60 60 60 10 65 60 65 11 65 65
0 1 2 3 4 5 6 0 X
60 X X X X
50 X X X
table 4 interior Cadra Nova
X combination not allowed 0 remove flue restrictor
Number is size in mm of the flue restrictor
3.2.1 Terminal position Verify if the required terminal position meets the local installation regulations regarding disturbance, good functioning and ventilation. (Also see: safety requirements). Note: The terminal must be located so that the outlet is not obstructed. If the flue terminal is located within 2 meters of a footway, path or where people could come into contact with it then a suitable terminal guard must be fitted.
3.2 Flue requirements (continuing)
Terminals located close to shared walkways, footpaths etc. could be subject to legal constraints and this should be pointed out to the customer before installation. If in any doubt about flue location advice should be sought from local building control, or if appliance- related, from the manufacturer including wherever possible a dimensioned sketch.
Effective height · Horizontal extension


Dimension Terminal position Balanced flue room sealed (kW input 7.5 kW expressed in net) Natural draught A Direct below an opening, airbrick, 300 mm opening windows, etc. B Above an opening, airbrick, 300 mm opening window ect. C Horizontally to an opening, airbrick, 300 mm opening window etc. D Below gutters, soil pipes or drain pipes 500 mm E Below eaves 500 mm F Below balconies or car port roof 600 mm G From a vertical drain pipe or soil pipe 300 mm H From an internal or external corner 600 mm I Above ground roof or balcony level 300 mm J From a surface facing the terminal 600 mm K From a terminal facing the terminal 600 mm L From an opening in the carport (e.g. 1200 mm window) into the dwelling M Vertically from a terminal on the same wall 1500 mm N Horizontally from a terminal on the same wall 300 mm P From a vertical structure on the roof 600 mm Q Above intersection with roof 500 mm

3.2.2 Using an existing chimney as air inlet You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function.

Requirements: - Any existing chimney used as an air supply must only service this appliance. - A chimney that has previously been used for solid fuel must be swept before use. - The existing chimney needs to be airtight. - The existing chimney needs to have an opening of min. 150 x 150 mm. - The chimney needs to be intact and well looked after. - Use the adjustable roof-mounted-terminal especially made for this, and the chimney connection set. - The minimum distance between two terminals should be at least 450 mm.
4.2 Preparing the appliances Widescreen and Whisper
4.1 Gas connection
gas supply routes when fire is fitted in a deep surround
C = Through wall - Pipe must be sleeved and sealed to fire
A & B = Behind surround - Sleeve pipe through surround


Remove the back panel by loosening the screws B (see fig. 6).
4.2 Preparing the appliances Widescreen and Whisper (continuing)


4.3 Preparing the appliance Misty (continuing)

4.4 Preparing the appliances Spectra Nova/Cadra Nova


4.4 Preparing the appliances Spectra Nova/Cadra Nova (continuing)

4.5 Fitting the firebox
2 Make the gas connection according to the instructions (also see gas connection, chapter 4.1).
Points of attention for placement: - If possible, first locate the appliance before assembling the flue. - If this is not possible then always use an extendible pipe before connection onto the appliance.

4.5 Fitting the firebox (continuing)
- Widescreen and Whisper; Place the glass in front of the appliance and fix it with the glass clamps. Replace the frame. - Misty, Cadra Nova and Spectra Nova: Place the door and fix it. Check on visual leakages around the door sealing.

4.6.1 Placing the log set Widescreen, Whisper, Spectra Nova, Misty and Cadra Nova
4.6 Placing the log set
On the bottom of the logs is a identification:
Never place extra elements of any kind into the combustion chamber. To guarantee good combustion, the log set may only be installed in the way specified by Faber International. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or missing logs.


5.1 Connections with use of concentric duct material
- The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre.
- To get the exact measure flue length you can use cut down- concentric pipe, wall mounted terminal or roof mounted terminal. To obtain a smoke sealed connection, the inner pipe must be 20 mm longer then the outside pipe.
- Because of expansion or cooling down the concentric pipes can turn loose. It is recommended to fix the spring clip with a self tapping screw at inaccessible places.
- The outside of the pipe can become hot (140 degrees). Stay 50 mm away from wall surface or sealing. Make sure to provide sufficiently heat resistant isolation when going through the wall or roof.
- Make sure the pipes are fixed sufficiently, a wall clamp every 2m, so the weight of the pipes is not resting onto the appliance.
- Make sure you place the pipes in the right direction, the narrow end towards the appliance.
- Make a hole of ø 153 mm for the wall or roof mounted terminal.
- Build the system starting from the appliance on.
UK/IRL UK/IRL

Requirements: - 300 mm of free space above the appliance; - The chimney only supply’s air to this appliance; - The existing chimney needs to be clean and very well swept; - The existing chimney needs to be airtight; - The existing chimney needs to have an opening of min. 150 x 150 mm.
You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function. Any existing chimney used as an air supply must only service this appliance.
5.2 Connection onto an existing chimney
F
D
A
B
Parts needed for this kind of installation: - Chimney connection set part number A9225000 Fig 20 part D - Short roof terminal part number A9266100 Fig 19 part B - Chimney closure plate part number A 9240000 Fig 19 part A - Two stainless steel tubes one 100 mm - length 500 mm and one 150 mm - length 500 mm part number A 9273900 Fig 19 part E and F
5.2 Connection onto an existing chimney (continuing)

5.3.1 Installation remote control 1. Connect the mains adapter to the receiver box. The adapter is set to the correct voltage in the factory 4.5V.
5.3 Remote control (if applicable)
Features: - Manual control will always remain possible. - The remote control is a radio frequency type and has been approved internationally. - The remote control generates a unique safety code every time you activate the transmitter, its similar to those used in a car. - The remote control is easy to install retrospectively.
The radio-frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria, Denmark, Finland and Greece.
The remote control is only meant to regulate the flames, it functions only when the pilot burner is ignited. It is therefore not possible to ignited the appliance with the remote control or to shut-off the pilot- flame.

Setting the right transmission code The receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the receiver is disconnected from the mains for a longer period.

6.2 Functional burner check
6.1. Check pilot ignition
1. Turn knob (B) to max. clockwise. 2. Turn the knob (A) more anticlockwise to the position (large flame). Now it is possible to light the main burner. 3. Turn knob B anticlockwise to max. The main burner should light. Check for gas soundness at all joints with leak detection floud! 4. Check the ignition of the main burner on low and high setting. 5. Turn knob B clockwise till {. The main burner is off. 6. Turn the knob A to {. The pilot should go out.
1. Push in and turn the control knob (A) from { anticlockwise to the setting (small flame). You will hear a tick meaning there is ignition. Hold the knob in and wait for a few seconds while the air is purged. 2. Bring the knob back in the start position and turn the knob several times to the position. Check that the pilot has lit. 3. Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable. 4. Release the knob. The pilot should remain alight.
6. COMMISSIONING (functional checks)
6.4 Check reference pressure
6.3 Functional balanced flue check
After checking the pressure, turn off the appliance. Remove the pressure gauge and close the sealing screw. Re-light the appliance. Turn to max. input and test around the test point D for gas soundness using a suitable leak detection fluid.
The pressure should be checked with the appliance alight and at max input. The setting pressure should be as shown at the technical data page 41.
The appliance is preset to give the correct heat input. No further adjustment is necessary. Fit a pressure gauge at the test point D to check the burner pressure.
1. Set the appliance on max. input. 2. Verify the flame picture, this means no flames against the window, the flame have to come besides the logs, if not check the log layout. 3. Check if the flames are yellow after 10 minutes of operation. If you still have a blue flame or the appliance goes out check: - If the flue pipes are fitted correctly (no leakage). - If the wall mounted terminal is placed with the correct side up. - If the correct flue restrictor is installed.
D C
A B
B A
UK/IRL UK/IRL

7.2.4 Recommend that the appliance should be serviced by a competent person at least once a year.
7.2.3 Hand over these instructions including the user guide to the consumer.
7.2.2 Instruct the customer on the operation of the remote control, including replacement of batteries and how to set the right transmissions code.
7.2.1 Advise the customer how to clean the appliance including the glass.
7.1 Instruct the customer on the full operation of the appliance.
8.1 Routine annual servicing
It is recommended, that the fire is inspected/serviced by a competent person at least once a year.
To ensure safe, efficient operation of the appliance, it is necessary to carry out routine servicing at regular intervals.

8.1.3 Propane conversion For conversion from propane to natural gas, order for a propane burner unit. Please give the serial number from the data plate when you order.
8.1.2 Cleaning the combustion chamber and burner You can clean the combustion chamber with a vacuum cleaner.
8.1.1 Cleaning the glass Depending on the intensity of use, you can get a deposit on the glass. This can be removed with a special ceramic glass cleaner (ceramic cook-top cleaner) as follows:
If the burner is visibly damaged, this can affect the distribution of the flame, if so then replace the burner.
Attention: Before placing the glass: check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in). Place the glass in front of the appliance and fix the glass frame or use the glass clamps.
8.1.5 Pilot/thermocouple assembly Remove the burner tray as described above. Now you have access to all the pilot and thermocouple parts.
8.1.4 Burner tray assembly 1. Remove the front, glass, log set, grid and burner tray cover. 2. Break the gas supply at the control valve. 3. Unscrew the burner assembly and take them out of the combustion chamber.
A. Pilot assembly B. Burner C. Fixation plate D. Injector E. Gas control F. Receiver

E F
B
A

8.1.6 Gas control block
A Governor B Adjusting screw pilot flame C Inlet pressure test point D Burner pressure test point
D C
B A
A B
8.1.7 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet.
A reading of CO in the room centre should give a rise of less than 9ppm over ambient, peak reading.
A Ratio of CO/CO2 should be less than 0.01 within 30 minutes. (100ppm CO per 1% CO2).

Touch Latch assembly 28103900 28103900 28103900 x x x
Set of glass clips 20900008 20900008 20900008 x x x
spray for comb. chamb. 09000008
Embers 20900019
Spark electrode 06006600
Thermocouple 37002033
propane 20900154
Pilot burner assemb.
Pilot burner assemb. NG 20900145
Motor (remote control) 37003086
Gas control 37003089
Adapter 20900142
Remote control 20603900
Receiver 20604000
Spark wire 06017300
Log set 20773200 20774500 20772500 20786130 20773700 20773700
Burner propane 20521835 20900167
Burner NG 20521808 20900166
Glass below x 04509600 04509400
Glass 04508200 04508300 04508300 04509000 4509500 04509300
Surround antracite A9271453 A9270053 A9267753 AA9272853 A9274149 A9274249
Whisper Feeling Silence Misty Spectra Cadra Nova Nova Description Company part
8.3 TECHNICAL DATA
Gas connection mm 8 mm nut 18 mm nut and olive. and olive
Remote control Adapter V 4,5 Batteries remote control 2x LR03 1,5 V Alkaline
Gas control GV36 with GV36 without pressure reg. pressure reg.
Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30
Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30
Injector size mm 3x 1,45 3x 1,00 1x 1,30 Reduced input restrictor mm 1,8 1,1
Reference burner pressure mbar 17 22
Gas rate 15 °C / 1013 mbar m3/h 740 231 kg/h 540 g
Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7,5 7,2 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 / 37
Country UK/IRL UK/IRL Category II2H3+ II2H3+
Heat resisting paint

Weight incl packing material kg 75 75 Dimensions: see table 1
Gas connection mm 8 mm nut 8 mm nut and olive and olive
Remote control Voltage adapter V 4,5 Batteries 2x LR03 1,5 V Alkaline
Gas control GV36 with GV36 without pressure reg. pressure reg.
Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30
Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30
Injector size mm 2x 1,40 3x 1,00 1x 1,30 Reduced input restrictor mm 1,8 1,1
Reference burner pressure mbar 17 22
Gas rate 15 °C / 1013 mba m3/h 790 231 kg/h 540 g
Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7,5 7,5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30/37
Country UK/IRL UK/IRL Category II2H3+ II2H3+
8.3 TECHNICAL DATA
Weight incl. packing material kg 75 75 Dimensions: see table 1
Gas connection mm 8 mm nut 8 mm nut and olive and olive
Remote control Voltage adapter V 4,5 Batteries 2x LR03 1,5 V Alkaline
Gas control GV36 with GV36 without pressure reg. pressure reg
Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30
Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30
Reduced input restrictor mm 1.8 1.1
Injector size mm 3x 1.50 3x 0.90
Reference burner pressure mbar 13 25
Gas rate 15 °C / 1013 mbar m3/h 800 231 kg/h 540 g
Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7.5 7.5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30/37
Country UK/IRL UK/IRL Category II2H3+ II2H3+
8.3 TECHNICAL DATA

Gas connection mm 8 mm nut 8 mm nut and olive and olive
Remote control Voltage adapter V 4,5 Batteries 2x LR03 1,5 V Alkaline
Gas control GV36 with GV36 without pressure reg. pressure reg.
Flue system MV size 100-150 100-150 Preinstalled flue restrictor mm 30 30
Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30
Reduced input restrictor mm 1,8 1,1
Injector size mm 3x 1,50 3x 0,95
Reference burner pressure mbar 16 25
Gas rate 15 °C / 1013 mbar m3/h 900 231 kg/h 540 g
Model type C11 0f C31 C11 0f C31 Heat input Hi kW 8,5 8,5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 / 37
Country UK/IRL UK/IRL Category II2H3+ II2H3+
8.3 TECHNICAL DATA
USER GUIDE
UK/IRL UK/IRL UK/IRL

9.1 General safety instructions
Switch off the receiver of the remote control if you don’t use the fire for a long time. Do not let children use the remote control without supervision.
Do not place curtains, clothing, laundry, furniture or other flammable materials nearby the appliance. The required minimum distance is 100 cm.
Due to the newness of materials, they may give off a slight smell for a period after initial lighting. This is normal, odours will disperse after a few hours use.
The appliance has been designed for heating purposes. This means that all surfaces, including the glass, can become very warm (over 100 degrees). An exception to this is the lower side of the door and the control buttons.
The fire has a safety device which turns off the gas supply if there is a build up from flue gasses in the combustion room or a temporary gas cut-off. Wait at least 5 minutes before turning the appliance on again. Contact a qualified installer when the appliance goes off regularly.
Do not use the fire with a broken or damaged glass.
These instructions should be read carefully and retained for future reference.
If a gas leak is found or suspected, turn off the gas supply at the meter and contact your installer or gas emergency service.
USER
Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot. As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance.
In your own interest and that of safety, all gas appliances must be installed by competent persons. Installation must be in accordance with National Regulations. CORGI registered installers are required to work to recognised standards.

10.1 Lighting the fire
With control button A you can light the pilot. With the control button B you can adjust the height of the flames (see fig. 27).
Cadra Nova and Spectra Nova Open by pushing the lip located on the right side in the gap between the ashtray door and the frame (door flaps open).
Misty Open the ashtray door by pulling down (bottom handle with gas damper).
Silence /Feeling /Whisper Open the ashtray door by pushing on the right side for the Silence/Feeling and on the left side for the Whisper.
The control valve is behind the ashtray door.
If the main burner or pilot light are extinguished for any reason, do not attempt to relight the pilot within 5 minutes. Contact a qualified installer when the appliance goes off regularly.
10. CONTROLLING THE APPLIANCE
fig. 27 control unit
10.2 To light
Knob B The { is the OFF position preventing gas entering the main burner if the pilot is lit. The knob should be turned slowly anticlockwise. This allows gas to enter the burner and be ignited by the pilot flame. Once ignition has taken place, the fire may be set to any level between min. and max. by adjusting the control knob B.
Knob A The { is the OFF position preventing any gas from passing through the control valve to either the pilot burner or to the main burner. By pressing the knob in it is possible to turn it anticlockwise. The first function is to turn on the gas to the pilot- this occurs just before reaching the |position (if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner). Once gas is available at the pilot, continued rotation anti-clockwise will cause the piezo igniter to spark. This is accompanied by a click at the valve and should result in the pilot burner igniting. Once the pilot is lit, the control knob should be held pressed in for 10 seconds. In this time the pilot flame will have heated the flame supervision thermocouple sufficiently to operate a hold- on magnet within the valve. Now turn the control knob A to the position. This allows gas to enter control knob B.

10.4 Remote control version
10.3.1 When the pilot extinguishes Warning! When the pilot extinguishes, for whatever reason, you should wait at least 5 minutes before trying to turn it on again.
10.3 To extinguish
Features: - Manual control will always remain possible. - The remote control is a radio frequency type and had been approved internationally. - The remote control generates a unique safety code every time you activate the transmitter, its similar to those used in a car. - The remote control is easy to install retrospectively.
The remote control is only meant to regulate the flames from off till max., it functions only when the pilot burner is ignited and knob A in (big flame) position. It is therefore not possible to ignite the pilot flame with the remote control or to extinguish the pilot flame. The radio-frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria, Denmark, Finland, and Greece.
Contact a qualified installer when the appliance goes off regularly.
Possible causes of pilot extinguish are: - Operating error. - Interference of the safety device. - Failure in the pilot flame system.
10.4.2 To extinguish 1. Push (low) till the burner goes out and you can hear the motor clicking.
10.4.1 To light 1. Push in and turn the control knob (A) from { anticlockwise to the setting (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).
remote control · high flame · low flame

10.4.3 Setting the right transmission code he receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the receiver is disconnected from the mains for a longer period,
10.4.4 Changing the batteries There is no risk of electric shock as the low voltage supply is similar to that used in torches. Always turn off the appliance before changing batteries.
AAA

To maintain the finish on the trim wipe with soft damp cloth only. Do not use abrasive cleaners, polish or solvents as these can damage the surface finish.
It is recommended that the fire is inspected/serviced, by a competent person at least once a year.
INSTRUCTIONS
Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities.
Batteries are considered chemical waste. The batteries should be disposed of responsibly and in conformity with government regulations. Remove the batteries before disposing of the remote control.
These materials should be disposed responsibly and in conformity with government regulations.