Instruction/ maintenance manual of the product XTRA SERIES Extron electronic
Go to page of 28
User Guide XTRA ™ Series Audio Products Half-Rack Audio P ower Amplifiers 68-2354-01 Rev . A 02 14.
Safety Instructions Safety Instructions • English WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated danger ous voltage within the product’ s enclosure that may pr esent a risk of electric shock.
FCC Class B Notice This equipment has been tested and found to comply with the limits for a ClassB digital device, pursuant to part15 of the FCC rules. These limits provide r easonable protection against harmful interfer ence in a residential installation.
.
Contents Introduction .................................................. 1 About this Manual............................................ 1 T erms Used in this Manual ........................... 1 Features ..............................................
.
Intr oduction About this Manual This manual contains information about the Extron XTRA Series of power amplifiers. • XP A 1002 two-channel stereo audio power amplifier • XP A 1002 Plus two-chann.
Extron patented CDRS — Class D ripple suppr ession — A patented, exclusive technology from Extr on that eliminates the high frequency switching ripple and EMI emissions found in typical Class D amplifiers. CDRS enables Extron power amplifiers to be situated near wireless A V devices without RF interference.
Installation This section discusses how to install the XTRA Series of audio power amplifiers. T opics that are cover ed, include: • Application Examples • Mounting the XTRA Series Amplifier W ARNING: Failure to follow these instructions may r esult in serious injury .
50/60 Hz 100-240V 0.3A L 1 R L 2 R L 3 R L 4 R L 1 R L 2 R L 3 R L 4 R L 1 R L 2 R L 3 R L 4 R L 3 R L 4 R I N P U T S O U T P U T S C O N T R O L I N P U T S O U T P U T S RESET ACT LINK RS-232 1 2 3.
2. Reduced air flow — Installation of the equipment in a rack should be such that the amount of air flow requir ed for safe operation of the equipment is not compromised. 3. Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Rack Mounting V entilation Recommendations Excessive heat can decrease the optimal lifetime of the power amplifier . An over temp indicator LED on the front panel of the amplifier lights r ed whenever the recommended operating temperature has been exceeded (see Fr ont Panel Features and Operation on page 9).
The optional Flexible Conduit Adapter Kit consists of: • One EMT adapter plate • One 6-foot long electrical conduit • Three 7.5 feet, 18-gauge spade connector power wir es • One UL-rated zip t.
3. Remove the 2 screws holding the hot (Line) and neutral wir es from the terminal block on the PCB (see figure 6). 100-240V 1.3A 50-60Hz Remove sc re ws (both sides) to re lease IEC connector plate. Remove nut Blue Wi re Brown Wi re L N Figure 6. Removing the IEC Connector 4.
Operation This section discusses how to operate the XTRA Series of audio power amplifiers. T opics covered, include: • Front Panel Featur es and Operation • Rear Panel Features and Operation Fr o.
c Limiter/Protect indicator LEDs — These LEDs (r epresenting their r espective output channels) light red under thr ee circumstances: 12 LIMITER/PRO TECT • When the output wiring is shorted together . • When audio clipping occurs, the LED of the corresponding channel blinks once per clip occurrence.
Rear Panel Featur es and Operation 100-240V 0.5A, 50-60Hz XP A 2001-70V LIMITER/PROTECT SIGNAL 0 2 4 6 8 10 12 18 14 26 ∞ ATTENU AT ION HPF 70 V OUTPUT REMOTE INPUTS CLASS 2 WIRING G G C V L (SUMMED) R 10V 80 Hz OFF 50mA STANDBY XP A 2001-70V Rear Panel XP A 1002 XP A 1002 Plus Rear Panel 100-240V 0.
d Attenuation — Use a small screwdriver to adjust the audio input level for the corresponding channel. The analog potentiometers contr ol the level from = (full attenuation) to 0 dB (no attenuation).
Do not tin the wires! Balanced Stereo Input Ti p Ring Ti p Ring Sleeves LR Unbalanced Stereo Input Ti p Sleeve Sleeve Ti p LR Unbalanced Mono Input Ti p Sleeve LR Balanced Mono Input Ti p Ring Sleeve LR or 1 2 INPUTS NOTE: The input connector receptacle may be labeled one of two ways.
MUTE VOLUME G 10K OHMS 2K OHMS MAX 2 C 3 1 V MIN 12 3 ST ANDBY MUTE SWITCH VOL/MUTE 10V 50 mA 45 or REMOTE G G C V 10V 50mA ST ANDBY Pin 5 (standby) connected to ground (pin 4) places the amplifier in standby mode. Standby mode turns off all output, although the amplifier is still receiving power .
12 OUTPUT XP A 1002 XP A 1002 Plus CLASS 2 WIRING 1 2 8 Ω /4 Ω OUTPUTS or A TTENTION: Do not tie channel outputs 1 and 2 to each other or to ground. Doing so will short the outputs, damage the amplifier , or both. NOTE: The power output of the XP A 1002 series can be effectively doubled by bridging the output.
ç Mono audio output connector — W ire the included 2-pole, 5 mm scr ew lock captive screw connector for mono audio (see the steps below). Output is designed to power 70 V (XP A 2001-70V) or 100 V (XP A 2001-100V) line distribution systems and is rated at 200 watts.
h High pass filter (HPF) toggle switch (XP A 2001 series) — Use a small screwdriver to toggle this r ecessed two-position switch. Setting the switch to 80 Hz (default) prevents the saturation of 70 V and 100 V speaker input transformers by low frequency signals.
Controlling Multiple Amplifiers with One V olume Controller Several XP A 1002 and XP A 2001 series units can be daisy-chained so that one volume controller can simultaneously r egulate the volume of all the amplifiers. NOTES: • As additional amplifiers are added to the daisy chain, the sensitivity of the volume potentiometer will change.
Bridged Mono Output The power output of the XP A 1002 and XP A 1002 Plus can be effectively doubled by bridging the output. Bridging allows power to be output in mono at 200 watts at 8 ohms. NOTES: • The bridging instructions that follow apply only to the XP A 1002 series.
T r oubleshooting The front and r ear panels have LED warning indicators, as described in the following diagnostic information. Amplifier Fails to Exit Standby Mode Promptly The input channel (channels 1 and 2) Signal LED lights green per indicated input channel when an input signal is detected.
Amplifier Enters Standby Mode T oo Early The input channel (channels 1 and 2) Signal LED lights green per indicated input channel when an input signal is detected. Power LED Color Signal LED State Problem Description Problem Solution Green or Amber Lit intermittently Enters standby mode early .
Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 F AX Extron Asia +800.
An important point after buying a device Extron electronic XTRA SERIES (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Extron electronic XTRA SERIES yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Extron electronic XTRA SERIES - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Extron electronic XTRA SERIES you will learn all the available features of the product, as well as information on its operation. The information that you get Extron electronic XTRA SERIES will certainly help you make a decision on the purchase.
If you already are a holder of Extron electronic XTRA SERIES, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Extron electronic XTRA SERIES.
However, one of the most important roles played by the user manual is to help in solving problems with Extron electronic XTRA SERIES. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Extron electronic XTRA SERIES along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center