User Guide XTP T UWP 302 XTP Extender T wo Input XTP T ransmitter – W allplate 68-2541-01 Rev . A 01 14.
Safety Instructions • English WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated danger ous voltage within the product’ s enclosure that may pr esent a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide r easonable protection against harmful interfer ence when the equipment is operated in a commercial environment.
Conventions Used in this Guide Notifications The following notifications are used in this guide: W ARNING: A warning indicates a situation that has the potential to result in death or severe injury . CAUTION: A caution indicates a situation that may result in minor injury .
Contents SIS Configuration and Control ..................... 17 Host Device Connection ................................... 17 SIS Programming Guide ................................... 17 Host-to-Device and Device-to-Host Communication ...............
XTP T UWP 302 • Contents vi.
XTP T UWP 302 • Introduction 1 Intr oduction This section contains general information about this guide and the Extron XTP T UWP 302 wallplate transmitter .
XTP T UWP 302 • Introduction 2 Key Featur es W all mountable — Mounts in a standard three-gang junction box or the pr ovided mud ring. Inputs — Include one HDMI input and one VGA input.
XTP T UWP 302 • Installation and Operation 3 Installation and Operation This section contains information for mounting, connecting, and wiring the XTP T UWP 302.
XTP T UWP 302 • Installation and Operation 4 Installing the Mud Ring or Junction Box Cutting an Opening in the Mounting Surface 1. Using an appropriate template or the mounting enclosur e as a guide, mark the area of the wall with a soft pencil that will be cut (for the provided mud ring, see Mounting T emplate on page 39).
XTP T UWP 302 • Installation and Operation 5 3. Insert the mounting bracket into the opening in the wall. 4. Rotate each backing clip so that the tab is behind the installation surface to hold the bracket snuggly in place when the screw is tightened.
XTP T UWP 302 • Installation and Operation 6 Installing a UL-certified Junction Box 1. Insert the junction box into the hole in the wall. 2. Secure it to the stud using two scr ews or nails, as appropriate. The front edge of the junction box must be flush with the front surface of the wall.
XTP T UWP 302 • Installation and Operation 7 b RS-232 Over XTP port — T o pass bidirectional serial or other control signals between XTP-compatible devices, connect a control device to the 5-pole captive scr ew connector . The port includes only the 3 poles labeled “RS-232.
XTP T UWP 302 • Installation and Operation 8 Mounting the XTP T UWP 302 Bac king Clip Extron XTP T UWP 302 AUDIO IN PWR H DCP HDMI VGA HDMI IN VGA IN Figure 7. Installing the XTP T UWP 302 in the Provided Mud Ring Wall Stud Extron XTP T UWP 302 AUDIO IN PWR HDCP HDMI VGA HDMI IN VGA IN Figure 8.
XTP T UWP 302 • Installation and Operation 9 Fr ont Panel Connections AU DI O IN PW RH DCP HDMI VG A HDMI IN VG A IN ab c Figure 9. Front Panel Connectors a HDMI connectors — Connect a digital video source device to the HDMI connector . It can accept HDMI, DVI, or dual mode DisplayPort video sources.
XTP T UWP 302 • Installation and Operation 10 Making Connections HDMI Connection Use an Extron LockIt Lacing Bracket to secur e an HDMI cable to each connector as follows: 3 3 1 2 4 5 Figure 11. Installing the LockIt Lacing Bracket 1. Plug the HDMI cable into the panel connection.
XTP T UWP 302 • Installation and Operation 11 TP Cable T ermination and Recommendations Use the following pin configurations for twisted pair cables.
XTP T UWP 302 • Installation and Operation 12 RS-232 and IR Over XTP Communication The RS-232 and IR Over XTP connector is for pass-through transmission of serial signals, such as projector contr ol signals, and Infrared data (see figure 13 for an example of how to wire the connector).
XTP T UWP 302 • Installation and Operation 13 Power Connection Apply power to the transmitter locally with the provided power supply or r emotely with a power injector or an XTP matrix switcher . A TTENTION: XTP remote power is intended for indoor use only .
XTP T UWP 302 • Installation and Operation 14 Remote power The XTP T UWP 302 can be powered r emotely through an XTP Power Injector or through an XTP matrix switcher . A TTENTION: XTP remote power is intended for indoor use only . No part of the network that uses XTP remote power should be r outed outdoors.
XTP T UWP 302 • Installation and Operation 15 Operation After all transmitters, all receivers, and their connected devices ar e powered up, the system is fully operational. If any problems ar e encountered, verify that the cables are r outed and connected properly .
XTP T UWP 302 • Installation and Operation 16 Reset Modes Use the recessed Reset button on the r ear panel of the transmitter to return the device to default settings or to restor e factory-shipped firmware. T o access the Reset button, the XTP T UWP 302 may need to be removed fr om the mud ring or junction box.
XTP T UWP 302 • SIS Configuration and Control 17 SIS Configuration and Contr ol The XTP T UWP 302 can be configured and contr olled using Extron Simple Instruction Set (SIS) commands or the XTP System Configuration Software (see XTP System Configuration Software on page 22).
XTP T UWP 302 • SIS Configuration and Control 18 Error Responses When the XTP T UWP 302 receives an SIS command and determines that it is valid, it performs the command and sends the corresponding r esponse to the host device. If the command is determined invalid or contains invalid parameters, the switcher returns an error response to the host.
XTP T UWP 302 • SIS Configuration and Control 19 Command and Response T ables for SIS Commands Command ASCII Command (Host to Device) Response (Device to Host) Additional Description Input Commands Input selection Select input X! ! In X!] Select input X! .
XTP T UWP 302 • SIS Configuration and Control 20 Command ASCII Command (Host to Device) Response (Device to Host) Additional Description Black signal for audio only NOTE: The switcher uses a black signal to simulate a 720p or 1080p, 50 Hz or 60 Hz signal so audio can be passed without video.
XTP T UWP 302 • SIS Configuration and Control 21 Command ASCII Command (Host to Device) Response (Device to Host) Additional Description EDID Commands NOTE: For EDID management, use the XTP System Configuration Software (see EDID Minder on page 33).
XTP T UWP 302 • XTP System Configuration Software 22 XTP System Configuration Softwar e This section contains installation and configuration procedur es for the XTP System Configuration Software for configuring and contr olling the XTP T UWP 302.
XTP T UWP 302 • XTP System Configuration Software 23 Using the XTP System Configuration Softwar e The XTP T UWP 302 can be controlled dir ectly from the side panel config port or remotely from an XTP matrix switcher . Connections When opening the XTP System Configuration Software, the Connections scr een opens first.
XTP T UWP 302 • XTP System Configuration Software 24 T op Menu The top menu bar contains three menus for configuring softwar e settings. File menu The File menu contains options for disconnecting and exiting the program. T o access the menu, click the File menu.
XTP T UWP 302 • XTP System Configuration Software 25 Update Firmware This option uploads firmware fr om the host device to the connected device. NOTE: If necessary , download new firmware fr om the Extron website (see Downloading Firmware on page 37).
XTP T UWP 302 • XTP System Configuration Software 26 Help menu The Help menu contains XTP System Configuration Software information, the help file, and a link to the Extron website.
XTP T UWP 302 • XTP System Configuration Software 27 Device Settings The Device Settings screen allows a user to view and edit various device settings for the device directly connected to the host device. Click the Device Settings icon on the Global Navigation bar to open the Device Settings screen.
XTP T UWP 302 • XTP System Configuration Software 28 Input/Output tab Click the Input/Output tab to open the Input/Output screen. It contains input information and options to apply automatic settings to individual inputs. Figure 27. Input/Output T ab Input name — Displays the input name.
XTP T UWP 302 • XTP System Configuration Software 29 Analog Video tab Click the Analog Video tab to open the Analog Video screen. It contains signal sampling, image shifting, and saving and recalling input pr eset options.
XTP T UWP 302 • XTP System Configuration Software 30 Audio tab Click the Audio tab to open the Audio screen. It contains settings for input format and analog audio gain. Figure 29. Audio T ab Input format section Input format — From the Audio Format dr op-down list, select the format for input 2.
XTP T UWP 302 • XTP System Configuration Software 31 General tab Click the General tab to open the general screen. It contains settings for executive mode, auto switch mode, and factory reset. Figure 30. General T ab Executive mode section Unlock the front panel — Click the Unlock Front Panel radio button (default) to disable executive mode.
XTP T UWP 302 • XTP System Configuration Software 32 Device Information panel The Device Information panel displays device information and settings. General Information section Model — Displays the device model. Firmware version — Displays the full firmwar e version.
XTP T UWP 302 • XTP System Configuration Software 33 EDID Minder Use the EDID Minder screen to assign unique EDID to the input or match curr ent output resolutions to the input. Click the EDID Minder icon on the global navigation bar . The EDID Minder screen opens.
XTP T UWP 302 • XTP System Configuration Software 34 Import EDID 1. On the EDID Minder screen, click the Add EDID to Library button. 2. Select the desired EDID file and click Open . The EDID appears in the A vailable EDID pane. 3. Assign the EDID from the A vailable EDID pane to import the EDID setting to the device.
XTP T UWP 302 • Reference Information 35 Refer ence Information This section contains mounting information and instructions for updating firmware. T opics in this section include: • Updating Firmw.
XTP T UWP 302 • Reference Information 36 Figure 34. Navigating to Firmwar e Loader 3. Navigate to Firmware Loader . 4. Click the Download link on the right that corresponds with the pr ogram. 5. Submit any requir ed information to start the download.
XTP T UWP 302 • Reference Information 37 Downloading Firmware Figure 35. Downloading Firmwar e from the Extron W ebsite 1. On the Extron website , click the Download tab. 2. On the left sidebar , click the Firmware link. 3. Navigate to the XTP T UWP 302.
XTP T UWP 302 • Reference Information 38 Installing Firmware with Firmwar e Loader Use the Firmware Loader utility to upload firmwar e to the transmitter when connected directly to the device. 1. Connect the host device to the side panel USB port. 2.
XTP T UWP 302 • Reference Information 39 Mounting T emplate Figure 37 is a example of a mounting template for pr eparing mounting surfaces. It is not to full size. T emplate for the 3-gang mounting bracket 6.41" (16.3 cm) 4.50" (11.4 cm) TEMPLA TE IS NOT FULL SIZE.
Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 F AX Extron Asia +65.
An important point after buying a device Extron electronic XTP T UWP 302 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Extron electronic XTP T UWP 302 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Extron electronic XTP T UWP 302 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Extron electronic XTP T UWP 302 you will learn all the available features of the product, as well as information on its operation. The information that you get Extron electronic XTP T UWP 302 will certainly help you make a decision on the purchase.
If you already are a holder of Extron electronic XTP T UWP 302, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Extron electronic XTP T UWP 302.
However, one of the most important roles played by the user manual is to help in solving problems with Extron electronic XTP T UWP 302. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Extron electronic XTP T UWP 302 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center