

Installation Guide for the PVS 200, 300, and 400
68-1390-01 Rev. C

This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
Power disconnection • To remove power from the equipment safely, remove all power cords from the rear of
the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be stepped on or pinched by
items placed upon or against them.
Retain Instructions • The safety instructions should be kept for future reference.
Servicing • Refer all servicing to qualified service personnel. There are no user-serviceable parts inside. To
prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Follow Warnings • Follow all warnings and instructions marked on the equipment or in the user
information.
Avoid Attachments • Do not use tools or attachments that are not recommended by the equipment
Slots and openings • If the equipment has slots or holes in the enclosure, these are provided to prevent
manufacturer because they may be hazardous.
overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced. Replace it only with the
same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance (réparation).
matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de tensions dangereuses non isolées posant des risques d’électrocution.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger, déconnectez tous les cordons
d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de manière à ce que personne ne
risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
d’utiliser le matériel.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-maintenance par un technicien
Conserver les instructions• Ranger les consignes de sécurité afin de pouvoir les consulter à l’avenir.
qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Respecter les avertissements • Observer tous les avertissements et consignes marqués sur le matériel ou
présentés dans la documentation utilisateur.
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci servent à empêcher
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni d’outils non recommandés par le
les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
fabricant du matériel car cela risquerait de poser certains dangers.
Lithium Batterie • Il a danger d’explosion s’ll y a remplacment incorrect de la batterie. Remplacer uniquement
avec une batterie du meme type ou d’un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten Sie alle Netzkabel
aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im Weg liegen und niemand
darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem Servicepersonal durchgeführt werden.
Bedienungsanleitungen genau durchlesen und verstehen.
Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie
aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist, dienen diese zur
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in der
Vermeidung einer Überhitzung der empfindlichen Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte, die nicht ausdrücklich vom
Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird. Ersetzen Sie verbrauchte
Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos.
indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida de alimentación eléctrica
al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben instalar en lugares donde
no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal calificado. En el interior no
equipo.
hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Conservar las instrucciones • Conservar las instrucciones de seguridad para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas en el equipo o en la
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento, es para evitar el
documentación del usuario, deben ser obedecidas.
sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Evitar el uso de accesorios • No usar herramientas o accesorios que no sean especificamente recomendados
por el fabricante, ya que podrian implicar riesgos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición incorrecta. Cambiar esta
batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas siguiendo las instrucciones del fabricante.
这个符号提示用户该设备用户手册中有重要的操作和维护说明。
(地线)是安全设施,不能不用或跳过 。 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后或桌面电源的电源线,或任何接到市
这个符号警告用户该设备机壳内有暴露的危险电压,有触电危险。
西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。必须使用与厂家推荐的相同或相近型号的电池。
按照生产厂的建议处理废弃电池。


This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
This manual covers the installation of the Extron PoleVault™ System in a drop ceiling room with a wood or concrete structural ceiling. If the location has a concrete or beam style ceiling, alternative ceiling mounts can be obtained separately from Extron (see 2c, "Optional items", later in this chapter). For those types of installation, refer to the individual mounting hardware user's manuals for method.
It is assumed that the installer has some knowledge and experience of A/V, electrical, or electronic device installation. This manual guides the A/V installer through the steps for installation and connection of each of the system’s component parts.
It may be that the locations for the devices (e.g., wall plates, projector, and screen) have been pre-determined. However, some room installation examples are given to help in installations where final location is yet to be determined.
Extron PoleVault Systems are easy-to-use, network-enabled, all-inclusive packages, making them ideal for single- projector K-12 classrooms. PoleVault Systems use economical twisted pair cables for transmitting signals and include network connectivity for Web-based asset management, monitoring, and control.

N The hardware and devices listed on the inventory pages have individual user manuals which have detailed safety
information, installation, set-up, and configuration instructions, and should be referred to as needed.
For operation and set up of the projector, screen, and input devices, refer to the relevant manufacturer's manuals supplied with those devices.


PV SI 3C LP Full Range Single Driver Ceiling Speakers
Projector on/off control Projector input switching Projector volume control 2 Gang (depth: 1.78”)
UTP network cable - not included PoleVault System installation and wiring overview

Before installation is started, several major factors must be considered to ensure that the overall installation is as smooth and trouble free as possible, and that the final finished project meets the needs of the customers, users, audiences, and installer.
The installation consideration on the following pages, though not comprehensive, should be consulted to help ensure that key aspects have been considered.
The application diagram below shows a typical classroom installation.

Room factors to be considered should include, but are not confined to:
Audience factors (e.g. number, ADA requirements, seating arrangements)
Existing installed furniture (bookcases, racks, cabinets, workbenches, sinks, etc.)
Windows, doors, and support pillar locations in relationship to the proposed screen location
Wall type: drywall, cement, brick etc.

W Check the structural ceiling to ensure that it can handle a load four times the weight of the final setup.

Type and control (important for projector image viewing)
Ambient light from windows
Teacher’s Desk TV / VCR / DVD Inputs
PVT A/V Wallplate Location
b. Location of the screen and projector
Normally located at the front center of the room (not covering fire alarm strobes when screen is lowered)
Dimensions and type of screen (maximum image size, motorized or hanging screen)
Aligned with center of the screen. Not an obstruction to viewing
Projector's throw distance (maximum and minimum limits to screen) of the image
Horizontal offset (horizontal distance from the center of the lens to the center of the projector)
Vertical offset of the projected image (height relationship between the projector and the screen)
Projector angle (image projected up, down, or horizontal to screen)
Projector weight. The Universal Projector Bracket (UPB 25) supports a maximum weight of 25 lbs.
Overhead clearances (refer to a copy of "ADA Standards for Accessible Design", "Section 4-4", "Head Room" for ADA requirements)
27" (68.5 cm)
Walking Parallel to a Wall
(ADA referenced figure 8a, redrawn)
PoleVault Systems Installation • Introduction — Planning 1-4

Pillars, furniture etc., window locations for glare reduction, obstructions between projector and screen

(ADA referenced figure 6c, redrawn) (ADA referenced figure 6b, redrawn) High Forward Reach Limits
High / Low Side Reach Limits
Max Side Reach over Obstruction Limits
(ADA referenced figure 5a, redrawn)
Desk, table, or rack mounted, proximity to proposed transmitter location (wall, podium, or furniture)
Studs, utility pipes, power supply location (raceway installation needed?)
Wall or floor cabled
Based on ceiling height and room size
Desired evenness of sound coverage and ambient noise level compensation

Each speaker covers one-fourth of listening area.
PVT A/V Wallplate Location
1-5 PoleVault Systems Installation • Introduction — Planning

The PoleVault System (PVS xxx) ships in two boxes. The larger box (42-1xx-xx) contain the devices and hardware, individually boxed and labeled. The smaller box (42-103-13) contains only the PV SI 3C LP speakers. Each PVS system has the same quantities of speakers, hardware and devices, but differ in the number and type of PoleVault A/V Source Input Wall Plates, and are shipped as follows:
Carefully check all the received items against the following lists.

UPB 25 Universal Projector Bracket PCM 240 Projector Ceiling Mount
(4) M6 x 40 mm screws (4) M5 x 40 mm screws (4) M4 x 40 mm screws (4) M3 x 40 mm screws 0.328 ID washers (4) #10 washers (4) #6 washers (4) Adhesive pads (4) Hex key (1)
(7) Replacement screws (2) Velcro™ pads (1) Set screw Hex wrench (1) Security screw Hex wrench
(4)Turnbuckles (5) Lag eyes screws (5) Concrete anchors (2) Cable clamps, Gal Steel (1) Safety wire (15 ft 1/8” dia) (2) Tie wire (30 ft, 14 AWG) (4) Locking Screws (4) Adhesive pads (1) Hex key
CAT5 T568A Patch, 50’ Quantity varies depending on PVS system ordered.
These may be boxed separately or loose inside larger box.


(1) 2-pole connector (orange) (2) 3-pole connector (blue) (1) 5-pole connector (blue) (1) Audio connector (black) (2) Securing screws (4) Tie wraps (4) Adhesive foot pads (2) Velcro® pads
(1) Mud ring (2) Dog legs (2) Dog leg screws (2) PVT mounting screws (1) Decora® Faceplate (2) Faceplate screws
(1) Mud ring (2) Dog legs (2) Dog leg screws (2) PVT mounting screws (1) Decora® Faceplate (2) Faceplate screws
(1) Mud ring (8) Mud ring screws (8) Replacement screws
*Part #’s 42-109-03 and 42-110-03 contain 3 or 4 PoleVault Wallplates, according to type ordered.


(2) Speaker grills (8 pcs) Grill putty (1) Grill key
N If any items in the PoleVault System boxes are damaged or missing, contact the Extron Technical Hotline (see rear

The following items are not included. However, input and display devices are essential parts of the system, and at any installation they may vary depending on their use. This list suggests various devices that may be used.
DVD/CD/VCR combo player (and cables)
Document camera (and cables)
PC or Mac (with keyboard, mouse, local monitor, VGA cables, RJ-45 network cables, power cords, and, where desired, a P/2 DA2 or DA for PC signal to local monitor and projector)
Bolts for concrete structural ceilings where needed
Toggles (used for screen mounting on dry wall)
S-hooks for hanging the screen
Spare ceiling tiles in case of accidental damage during installation
Electrical box, where installation of a box on the PCM 240 is desired
Safety wire, lag eye bolts, and strain reliefs for installation and securing ceiling speakers
Heat shrink, extension cord
The optional items suggested below can be added to or substituted for items in the standard PoleVault System.
MLP 101 D (mic to line pre-amplifier)
Wall mount speakers (e.g., SI 26) or extra ceiling speakers
MLC 104 IP Plus DV+ controller (includes DVD/VCR IR control)
MLC 104 IP Plus L controller (with lectern faceplate)
MLC 104 IP Plus AAP controller (with AAP opening)
PPC 25 Priority Page Controller
FCMP (flat ceiling mount)
ACMP (angled ceiling mount)
SMB (surface mount boxes for installing the MLC on a podium or desk)
EWB (external wall boxes to mount devices for a surface raceway system)
MLM-WB+ (lockable metal wall box with flip-down 4U rack space)
PVT CV AAP (composite video architectural adapter plate model)
PVT RGB AAP (RGB architectural adapter plate model)
PVT RGB (RGB rack mount model)
PVT SW RGB (RGB rack mount model with switching capabilities)
PVT CV (composite video rack mount model)
PVT RGB CV (RGB and composite video rack mount model)
SI 3 (Compact Full-Range Surface Mount Speakers)
SI 26X (Two-Way Open Back Ceiling Speakers)
SI 26W (Two-Way-In-Wall Speakers with 6.5" Woofer)
SI 28W (Two-Way-In-Wall Speakers with 8" Woofer)
SI 26CT (Two-Way Ceiling Speakers with 8" Back Can and Transformer)
SI 26 (Two-Way Surface Mount Speakers with 6.5" Woofer)

To aid the professional installer, this checklist gives the tools recommended to complete the installation. Tools should include, but are not confined to:

This overview outlines the basic steps for installing the PoleVault System. Detailed description of these steps is given in five sections, Stages One though Five.

N Additional installation hardware is needed and should be supplied by the installer. See Introduction, “Items not
included”, for a list. Optional accessories may be desired for this installation. See Introduction, “Optional items”, for a list, or visit www.extron.com for details. Refer to local building standards and codes to verify that the installation will meet all the regulatory requirements. Observe all local and national building and safety codes, UL requirements, and ADA Accessibility Guidelines. For details of the OSHPD approved method of installation (OPA-1782), consult the PCM 240 User’s Manual, 68-1180-01, Rev D. Refer to the specifications on pages 2-31 through 2-33 for system hardware weights and dimensions.
Carefully check inventory of PoleVault system packages, input and output devices, any optional accessories, and installation hardware before commencing.
Outline of installation steps Stage One — Install the Screen and Projector.

c Mark the screen location (page 2-3).
c Install projector to verify location (page 2-3).
c Verify the image location (page 2-4).
c Cut the ceiling tile (page 2-5).
c Finish projector ceiling mount installation (page 2-5).
c Secure the projector ceiling mount to the ceiling (page 2-6).
c Install the screen (page 2-7).
Stage Two — Install the A/V Source Input Wall Plates and MLC 104 IP Plus.
c Install the mud rings (page 2-10).
c Pull cables (page 2-11).
c Install the wall plates (page 2-12).
c Install the MediaLink Controller (page 2-13).
Stage Three — Install the PV SI 3C LP Ceiling Speakers.
c Cut the ceiling tile (page 2-17).
c Install the speaker in the ceiling tile (page 2-17).
c Secure the speakers to the structural ceiling (page 2-18).
c Cable the speakers (page 2-18).
c Finish speaker installation (page 2-20).
Stage Four — Install the PMK 450 and the PVS 204SA.
c Pull the cables (page 2-22).
c Install the PMK 450 pole mount kit (page 2-22).
c Install the PVS 204SA switcher (page 2-23).
c Finish installing the pole mount kit (page 2-24).
Stage Five — Configuring the system.
c Configure the system (page 2-26).
c Test the system (page 2-28).
c Final installation (page 2-29).
Where possible in the following pages, line drawings and photos from an actual installation are used to clarify some of the steps discussed in the text. Each image has a number corresponding to the particular step (e.g., Ñ) described.

Stage 1
This stage involves installing the three pieces of hardware shown below.

1-gang and 2-gang Accessory Mounting Points (e.g. power sockets)
Where it goes: Attaches to structural ceiling, rests on suspended ceiling.
What it does: Holds Pole Mount Kit and projector.
What it does: Holds PMP, Pole Mount Kit (see Stage 4), and projector.
Where it goes: Adjuster plate screws onto base of PMP, and projector bracket attaches to projector.
What it does: Attaches projector to PMP. Allows projector orientation to be adjusted in three planes.



T When marking the location of screens, devices, or site
for installing transmitters and MediaLink control devices, use painters’ tape to avoid wall surface damage.
When marking the center line of the screen, where possible, keep it aligned with the center of the ceiling tile. This makes the projector installation and alignment easier.
b. Mark any structural studs, utility pipes, conduits,
or fire-breaks before drilling the hardware holes. Do not drill the holes at this time.

minimum throw distances on the T-frame.
b. Place the PCM 240 over the T-frame, between the two
marks. Lightly tighten the frame screws.
c. Back out the set screws on the PCM 240 adapter plate

and screw the PMP into the pipe adapter, with the cable access hole closest to the ceiling. Turn it so the cable access hole faces away from the screen. Tighten the set screws.
d. Back out the set screws on the top portion (the adjuster
plate, see a below) of the UPB 25, and screw the plate onto the base of the PMP. Align it so the security flange is at the rear. Tighten the set screw.
a
Loosen the four Adjuster Plate Locking Screws and slide the Adjuster Plate away from the Projector Bracket
Adjuster Plate Locking Screws (4)
Set Screws (2) · Adjuster Plate · Projector Bracket

e. Using suitable screws, mount the projector onto the
lower portion of the UPB 25 (the projector bracket, see b in step 2d’s drawing). Align it so the security flange is at the rear. A minimum of three arms need to be attached to the projector Adjust the arms to fit as needed. Lock down the arm adjustment screws.

T Adjust the threaded barrels at the end of each
arm to keep the bracket level.
f. Lift the projector up to the mount plate and slide it into
place. Tighten down the locking and pivot screws.
b. Verify image size and location by loosening the
PCM 240 adapter plate locking nuts, and adjust the plate (left-right) to center the image.

T Remember to include the vertical and horizontal offsets
when aligning the projector. Refer to the projector manual for information.
Measure the horizontal offset
c. When satisfied lock down the plate locking nuts.
Projector Center Line · Lens Center Line · T Horizontal offset

removing it. This aids putting it back in the correct location when the tile is replaced.

T Mark the screen direction on back of the tile (e.g. with
an arrow or “to front”) to help orientation of tile when replacing it after cutting.
b. Measure the distances X and Y (see figure) from the inner
vertical section of the front and left T-bar runners to the center of the Pipe Adapter Plate.
Minimum and Maximum Throw Distance Marks
c. Using these dimensions, mark and cut a hole for the
PMP in the ceiling tile.

T Place the tile on a box, mark hole center on the
underside of the tile. Use a hole saw bit to start to cut the hole by hand (turning bit counter clockwise) to avoid damaging the tile. When the drill bit is through the tile, turn the tile over and finish cutting from the top side.
4c Mark and start cutting the hole on the underside. Finish on the top side.
mounting pole. Do not remove the projector bracket from the projector.

b. Loosen the PCM 240 ‘s set screw and remove the
mounting pole, then remove the PCM 240.
c. Replace the cut ceiling tile, checking the orientation to
align the hole with the PCM 240.
d. Replace the PCM 240 over the ceiling tile and screw
the mounting pole (with the access hole uppermost) up through the hole into the mounting plate. Tighten the set screws.
T-bar


C DO NOT rest or lean on the mounting plate or
suspended ceiling when attaching turnbuckles, tie wire, or when drilling into the ceiling
b. Mark and drill holes at 10 degrees out from vertical.
Drill a fifth hole directly centered above the PCM 240 for the safety cable.
c. Install appropriate anchors or lag eye-bolts for the
structural ceiling into each drilled hole
d. Cut four equal lengths of the supplied hanging wire, and
loop the wire through the anchors or eye screws, and the turnbuckles, then twist the wire around itself at least five times tightly.
e. Hand tighten the turnbuckles, and level the plate so it
just rests on the grid.

C The four hanging wires should be taut, taking
the full weight of the completed installation.
Do not overtighten the turnbuckles or the T‑bar assembly could be lifted, making the suspended ceiling bowed and unsafe.
Adjust the turnbuckles to take up any slack in the hanging wire.
f. Tighten the four T-bar securing screws on the PCM 240.
g. Mark a point in the ceiling directly above the plate’s
center, drill a hole and install a ceiling anchor or eye screw
C DO NOT rest or lean on the plate or suspended ceiling grid during installation of safety cable, or during installation and wiring of electrical boxes, accessories, and projector.
T-bar


h. Pass the safety cable through the anchor and attach it to
the center holes on either side of the plate. Ensure the cable is of equal length on both sides of the anchor and secure the cable using the cable clamps.
Attach safety cable to center holes and secure with cable clamps.
T Install any optional power outlets in the 2 gang opening
on the mounting plate, towards the outside edge of the mount, so it does not interfere with the PMK 450 when installed.
C For safety, all wiring of the electrical boxes and
accessories should be completed after the plate is fully installed and secure.
Install power outlet in the 2-gang cutout (RACO box installed)
to install the screen mounting brackets and then hang the screen.

T Use S-hooks to hang the screen from the brackets.
Bend the ends of the S-hooks so the screen does not fall when it is rolled up.

Stage 2
This stage involves installing the devices shown below.

PVT CV D and PVT RGB D PoleVault A/V Source Input Wall Plates
Audio and Video output ports (2* - at rear)
* Each RGB wall plate needs 2 output cables, A and B.
Where it goes: Installs in a wall near input location.
What it does: Transmits an input’s composite or RGB video and audio signals to the switcher.
Where it goes: Installs in a wall at a location convenient to user.
What it does: Provides remote control of switcher and projector.




local electrical codes, and UL requirements. Refer to the devices’ user manuals for details.
mud ring or a wall box. If installing a box, allow enough depth for the plate, and the cables. The box should be at least 2.5" (6.4 cm) deep to accommodate the connectors and cables. If a suitable wall box is already installed, follow step 2 onwards.
a. Mark the holes for the mud rings.

b. Cut out the material from the marked area.
c. Insert the mud ring into the opening. The mud ring’s
rear connectors should fit easily into the opening. Bend over the mud ring doglegs and secure with the screws provided.
Repeat steps a to c for all the transmitters needing to be installed.
d. At the desired location repeat steps a to c for the larger


N For PVT RGB D Wall plates, two CAT 5 signal
cables for each input are needed.
Maximum distance from the PVS 204SA to the Wall plates is 100 feet. The optimum distance is between 50 and 75 feet.
The CAT 5 cables supplied are terminated to the TIA 568A standard. Other CAT 5 cables can be used if they are TIA 568A or 568B standards and terminated to the same standard at both ends.
then wrap the clear section around it.
2b Use the supplied labels for clear cable identification during installation.
a. Drill cable pathways through any obstructions
(e.g., wall caps, fire-breaks, or horizontal studs).
b. Label the CAT 5 signal cables at both ends with the
RGB 1A (Input 1 RGB) Orange
supplied labels. Refer to the PVS 204SA User’s Manual for labeling details.
RGB 1 B (Input 1 RGB) Orange w/black stripe
RGB 2A (Input 2 RGB) Yellow
RGB 2B (Input 2 RGB) Yellow w/black stripe
Video 3 (Input 3 Composite Vid) Green
Video 4 (Input 1 Composite Vid) Red

c. Pull the cabling through the wall from the ceiling space
down to the location of the transmitters and other wall devices, and out through the openings.
T Secure cables with cable clamps to provide strain relief.
Trim back the outer foil shield to the point where the
cable exits the cable clamp, and insulate exposed cable shields with heat shrink to reduce the chance of short circuits.
Both braided and foil shields should be connected to an
equipment ground at the other end of the cable.


(for RGB devices, cable labeled A to port A, cable B to port B).
3a Connect the cables to the A/V source input devices at each location.
b. Mount each device into the mud ring.
c. Attach the supplied Decora faceplate.
d. Label the Decora plate with the supplied label, using the
appropriate input number. This makes inputs easier to identify when configuring the switcher.
e. Repeat steps a-d for other wall plates.
3b Mount the PVT in the mud ring, then attach 3c and label 3d the Decora faceplate.


T Before cabling and installing the MLC 104 IP Plus,
locate and write down the MAC address of the device for configuring the IP address. The 12 character alphanumeric address (e.g., 00-05-A6-03-9G-H4) can be found on a label on the rear of the controller.
Heat Shrink on Outer Jacket to Inner Conductor Transition
T The length of exposed wire is critical to avoid
transmission problems. Ensure the lengths given here are adhered to when stripping the cables for connection.
N If a drain wire is used, both ends of the
wire must be covered by heat shrink to avoid accidental grounding.
a. Connect the MLC power and RS-232 control cable as
shown.

N The MLC 104 IP Plus is powered from the
PVS 204SA. DO NOT connect an external power supply to the MLC 104 IP Plus unless installing an optional secondary control panel.
PVS 204SA Switcher's rear panel RS-232/MLC/IR port A B C D E
A - (Rx on the MLS port) White A - (Tx on the RS-232 port)
B - (Tx on the MLS port) Violet B - (Rx on the RS-232 port)
the drain wire to ground at both ends. Apply heat shrink cover to both ends of the wire to avoid accidental grounding.


4b Connect the MLC to the projector with an RS-232 cable or IR emitter cable, as appropriate.
c. Connect a CAT 5, 5e, or 6 straight through cable to the

The connections between the MLC 104 IP Plus and the PVS 204SA switcher should look like this.

Plenum Rated UL 2043 Suitable for Use in Air-Handling Spaces
e. Sliding the cables into the opening, secure the

MLC 104 IP Plus to the mud ring with the provided machine screws

Stage 3
This stage involves installing the devices shown below.

Where it goes: Installs in ceiling tiles at predetermined location for best acoustics. Connects to switcher.


N The installation must conform to national and

local electrical codes, and UL requirements. Refer to the device’s user manual for details.
a. Remove the ceiling tiles where the speakers are to be
installed.

T For ease of working on the speaker when it is replaced
on the T-bar, remove an adjacent tile(s).
b. Locate the tile center, and using the supplied template,
trace and cut the hole for the speaker.

T Place an empty box under the tile for support and to
collect the waste.
Measure and mark the center point of the tile and align
the cross marks with those on the supplied template.
Use a fine hacksaw blade to cut the tile without
damaging the face.

a. Lay two supplied speaker V-rails across the tile on either
side of the hole.
b. Remove the C-ring from the speakers and attach it to the
center of the V-rails with the supplied hardware.

T At the ends of each V-rail, bend the tabs upwards.
This makes it easier when replacing the tile back on the T-bars. When installation is complete, bend the V-tabs down onto the T-bars
2a Place the V-rails on either side of the hole, insert and 2b attach the C-ring

Bend the end tabs upwards.
c. Remove the plenum cover from the speaker terminals

Loosen the screws and remove the plenum cover.
d. Insert the speaker into the ceiling tile from the face side.

e. Loosen the four screws on the front baffle (counter

clockwise) 1/2 turn (see figure, A) and turn the doglegs to lock onto the C-ring. Tighten down the front screws (see figure, B).

T Use a handheld screwdriver, as a powered screwdriver
may slip and damage the speaker.
f. Repeat steps a through e for each speaker that is to be
installed.

b. Bend down the V-rail tabs to hold it in place and give
added support.
c. Drill a hole into the structural ceiling and install a lag eye

bolt at a suitable location over the speaker.
Mark, drill a hole, and insert a lag eyebolt in the structural ceiling.
d. Attach a hanging wire to the speaker seismic tab.
Attach hanging wire to the speaker (seismic tab) and to the eye bolt.
run the cable from the PVS 204SA to the first speaker in the speaker system being installed.

b. If not using conduit, insert a ½" clamp into the terminal
(plenum) cover knockout and pass the cable through the knockout. Clamp the cable or conduit to the cover.
Attach the Conduit or Cable to the Terminal Cover

c. To terminate the cable, strip the end of the cable 0.2" (5

mm) and secure the wires into the supplied 4-pole captive screw connector.
d. Plug the 4-pole connector into the speaker terminal and
observed when setting up a speaker system See figures below for examples.
Two 8 ohm speakers wired in parallel equal a 4 ohm load.


speaker, using the supplied adhesive tabs (putty) to secure it in place.
Apply 4 pieces of black putty (supplied), equally spaced 90° apart, to the upper inside edge of the grille.
5a Apply putty to speaker grill.
b. Repeat cabling and final installation steps for all
speakers, connecting the speakers according to the system preferred (e.g in parallel, see page 2-19)

Stage 4
This stage covers installing the devices shown below.

Where it goes: Attaches to PMP around cable access hole, above the projector.
What it does: Supports and hides the installed PVS 204SA switcher, power supply, and any installed optional accessories.
Plenum Rated UL 2043 Suitable for Use in Air-Handling Spaces
Where it goes: PVS 204SA and power supply install on the base plate of the PMK 450.
What it does: Receives input video and audio signals from A/V source input wall plates, outputs and switches the signals to projector and ceiling speakers.


N The installation must conform to national and local
electrical codes, and UL requirements. Refer to the device’s user manual for details.
a. Loosen the PCM 240 set screws and remove the PMP.

b. Gather all the cables from the speakers, A/V wall plates,
MLC 104 IP Plus controller, and any optional devices installed that have been run to the projector location, and pull them down through the hole in the ceiling tile. These cables are: the MLC power/RS-232 cable, the CAT 5 input cables from the wall plates, the speaker cables, the MLC to projector IR/Serial comms cable, any optional device cables (e.g. PPC 25 sensor)
c. Gather the cables together below the suspended ceiling
1c Gather the cables, pass them down the PMP and 1d screw it into place.
and pass them down the PMP.
d. Screw the PMP back up into position and tighten the set
screws on the PCM 240.

Slide the top cover upwards until it is located just above the cable access hole.
remove the side screws, and slide the top plate forward and away from the base plate lugs.


b. Slide the PMK 450’s top plate up the projector pole until
it is located just above the cable access hole.

PMK 450 Top Plate
c. Level the plate and secure it in place with the four set
screws located on the collar, ensuring that a minimum of three set screws are tightened firmly against the pole. Rotate the pipe if necessary to achieve this.
d. Pull the CAT 5 cables from the wall plates, the speaker’s
cable, and the MLC control cable through the access hole, ready for connection to the switcher. Leave the MLC to projector serial communications cable to hang out of the bottom of the pipe.

Cables from A/V wall plates, MLC 104 IP Plus, and SI 3CT LP speakers.
1 1 1 2 3 4 4
e. Insert the output video signal cables (VGA and RCA)
Cables to PVS 204SA
into the access hole and pull them down the pipe so one end hangs out the pipe with the MLC to projector communication cable. These cables connect to the projector later.
A/V wall plate cables, RGB (2), Video (1)
MLC 104 IP Plus switcher control cable
4 SI 3CT LP speaker cables
Cables from PVS 204SA
2 MLC 104 IP Plus projector control cable


bottom plate into the holes in the base of the switcher, and secure it in place at the left front of the bottom plate.
N Do not install the rubber feet on the switcher
b. Install the power supply on the right rear of the
PMK 450 bottom plate and secure it using velcro.
3a Install the switcher and power supply onto the base plate of the PMK 450
c. Attach the supplied 2-pole male captive screw connector
to the cord of the supplied power source and connect the power cord to the rear of switcher.
T Insert the extra captive screw connectors into any
ports which are not going to be used at this time. This keeps the connectors handy for any future system modifications.
d. Set the DIP switches on the rear panel of the
PVS 204SA to Dual Mono and high pass filter off. Refer to the PVS 204SA User’s Manual for details.

Plenum Rated UL 2043 Suitable for Use in Air-Handling Spaces
e. Install any other optional devices, such as the Extron
Priority Page Sensor Kit on the PMK 450, following the installation steps in the devices’ user’s manuals. See the “Optional Accessory Installation — PPC-25” section in this manual for an overview.


and power supply installed) up to base of the pole and connect the cables as follows:
b Control/power cable from the MLC 104 IP Plus
f Power supply cable. Do not apply power yet.
N Do not thread the power cable through the
projector pipe. Threading the power cable through the pipe violates national electrical regulations.
PVT RGB D Input (2 cables, A and B)
Plenum Rated UL 2043 Suitable for Use in Air-Handling Spaces


b. Align the bottom plate lugs with the slots in the top plate
and slide up and into place.
c. Attach the rear plate to secure the PMK 450. Ensure the
power cable exits via the cable notch in the top plate, or via the gap in front of the filler plate at the bottom.
d. Screw the UPB 25 adjuster plate back onto the base of the
PMP, and replace the projector (with the UPB 25 bracket attached) on the adjuster plate.
e. Connect the switchers VGA and RCA cables to the
projector.
f. Connect the projector control cable from the MLC to the
projector. Refer to the projector’s user manual for RS-232 control port pinout details.

Stage Five — Configure the System
Stage 5
Items needed to help complete this stage:


(GC2) configuration program (available at www.extron.com) on the laptop or PC
b. Ensure the laptop (or PC), and the MLC 104 IP Plus are
connected to the LAN.

N If this is not possible, connect a 2.5 mm TRS
configuration cable (part # 70-355-01) to the laptop (or PC) and to the front panel configuration port of the MLC 104 IP Plus.


c. Launch GC2. Click on Help, then Contents (or press F1).

d. Select the MLC 104 IP Plus/PoleVault system from the


drop-down box. Follow the instructions on the help page.
e. To move to the next page (shown in the yellow box),


click the NEXT button above the drop-down box. Repeat as needed, following the instructions on the pages to configure the MLC 104 IP Plus, as needed.
1e Click next to navigate through the pages to configure the MLC 104 IP Plus


and power on the MLC 104 IP Plus.
2a Turn on the MLC 104 IP Plus controller and the PVS 204Sa switcher
b. Connect all the input devices (e.g., PC, DVD, document
camera, etc.) to the transmitters and power up the input devices. Check that power and signal are present at the transmitters. The LEDs light red when only power is present and light green when power and a signal are present.
c. Power on the projector and with a video source (PC
or DVD playing) check that a good image is shown on screen. Adjust projector settings as follows:

Tighten these 2 set screws (one each side) to lock the UPB onto the pole.
2c Check that an image is present, adjust as needed.

d. Test the controller’s configuration with the following:

e. Adjust the audio input sensitivity as follows:
MIN/MAX CLIP AUX/MIX LEVEL
This LED flashes when the amplifier output is clipping.
f. If necessary adjust the amplifier level by rotating
the same encoder used in Step e.
2e Set MLC volume to maximum, and adjust the level on the switcher
g. If necessary set the Aux/Mix level by rotating the
Aux/Mix encoder.

cable exits the unit through the power cable access slot at the rear.
Tighten Front and Rear Plate Screws (4) and Side Screws (2)
Cable from power source
b. Tighten down all six screws on the PMK 450, four on
the front and rear plates, and two on the sides.
3a Replace the front plate and 3b tighten down the screws on the mounting kit
c. Check and tighten the adjuster plate locking screws
on the projector bracket.
Front Plate

The example below is the installation of the optional accessory Priority Page Controller and Sensor (PPC 25). The Priority Page Controller momentarily silences classroom audio whenever a page is made from a public address (PA) system.
For detailed information, refer to the PPC 25 Installation Instructions, supplied with the device.

N Follow all local fire and safety code requirements for installation and anchoring.
b. Loop (only) one of the Paging speaker wire leads around
the top (open) part of the Sensor. Either speaker wire will work. Leave the other speaker wire connected directly to the Paging speaker. Polarity need not be observed.
c. Close the top of the Priority Page Sensor.
supplied blue sensor cable, for use in step 3.
b. Connect the bare wire end of the supplied blue sensor
cable to the 2-pole captive screw connector on the Page Sensor. Polarity need not be observed.
c. Route the connector end of the sensor cable to the PPC 25
Controller and plug it into the Paging Sensor port.

port on the PPC 25 Controller and to the mute and ground pins on the PVS 204SA Vol/Mute port. Polarity need not be observed.
b. Use the included power supply cable assembly
(PN 27-576-01LF) to power the PPC 25 from the PVS 204SA power supply. The PPC 25 must be mounted near the PVS 204SA and its power supply.
Plenum Rated UL 2043 Suitable for Use in Air-Handling Spaces

Specifications
For detailed specifications and warranty information of the PoleVault System components, refer to the device manuals, or the product pages at www.extron.com
PCM 240
Mounting Drop ceiling mount Enclosure type 14 gauge steel/powder coated white Plate dimensions 25.8" L x 8.0" W x 1.2" D (65.5 cm L x 20.3 cm W x 3.0 cm D) Product weight 5.6 lbs (2.5 kg) Listings UL, CUL as an accessory, for use with UL Listed mount and projector Compliances CE, OSHPD anchorage pre-approval Vibration ISTA 1A in carton (International Safe Transit Association)
Material Steel Pipe Color/finishes White or black powder coat Pipe dimensions 6" length, 1.5"-11.5 NPT threads) Product weight 1.0 lbs (0.5 kg) Listings UL, CUL as an accessory, for use with UL Listed mount and projector Compliances CE Vibration ISTA 1A in carton (International Safe Transit Association)
Mounting Mountable to round projector mount pipes with an outer diameter of 1.85" to 1.95"
(4.7 cm to 5.0 cm) using included hardware Maximum load 15 lbs (6.8 kg) Enclosure type (material) Metal Enclosure dimensions 2.32" H x 12.25" W x 11.63" D (5.9 cm H x 31.1 cm W x 29.5 cm D) Product weight 2.4 lbs (1.2 kg) Listings UL, CUL Compliances CE Vibration ISTA 1A in carton (International Safe Transit Association)
Material Steel General dimensions Refer to UPB 25 Manual Product weight 3.7 lbs (1.7 kg) Maximum capacity 25 lbs (11.3 kg) Listing UL, CUL as an accessory, for use with UL Listed mount and projector Compliances CE Vibration ISTA 1A in carton (International Safe Transit Association)
N Specifications are subject to change without notice.

PVS 204SA
External power supply 100 VAC to 240 VAC, 50/60 Hz, external, autoswitchable; to 12 VDC, 3 A, regulated Power input requirements 12 VDC, 0.97 A (typical) Temperature/humidity Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing Enclosure type Metal Enclosure dimensions 1.7" H x 8.7" W x 3.0" D (1U high, half rack wide) (4.3 cm H x 22.1 cm W x 7.6 cm D) Product weight 2.5 lbs (1.1 kg), plus power supply 0.8 lbs (0.4 kg) Vibration ISTA 1A in carton (International Safe Transit Association) Listings UL, CUL, (UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release,
excluding the power supply; meets UL 60065 for safety) Compliances CE, FCC Class A, VCCI, AS/NZS, ICES MTBF 30,000 hours
Power Supplied by the PVS 204SA twisted pair receiver/switcher Power input requirements 12 VDC, 0.19 A (0.305 A if used with an optional IRCM-DV+) Temperature/humidity Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing Rack mount Wall and furniture mountable Enclosure type Metal Enclosure dimensions MLC 104 IP Plus faceplate 4.5" H x 4.6" W x 0.1" D (11.4 cm H x 11.7 cm W x 0.3 cm D)
MLC 104 IP Plus device 2.7" H x 3.4" W x 1.8" D (6.9 cm H x 8.6 cm W x 4.6 cm D) (Depth excludes knob and buttons. Fits some 2 gang boxes. Allow at least 1.9" [4.8 cm] depth
in the wall or furniture.) Product weight 1.9 lbs (0.9 kg) Vibration ISTA 1A in carton (International Safe Transit Association) Listings UL, CUL Compliances CE, FCC Class A, VCCI, AS/NZS, ICES, Section 508 of the Rehabilitation Act
(29 U.S.C. 794d) MTBF 30,000 hours
Power Supplied by the PVS 204SA twisted pair receiver/switcher Power input requirements 5 VDC, 0.10 A for PVT CV D; 5 VDC, 0.15 A for PVT RGB D Temperature/humidity Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing Mount Wall or furniture mountable with included Decora wall plate. Enclosure type Metal Enclosure dimensions Faceplate 2.6" H x 1.3" W x 0.3" D (6.6 cm H x 3.3 cm W x 0.7 cm D)
(fits the opening in a 1 gang Decora plate) Device 2.6" H x 1.6" W x 0.7" D (6.6 cm H x 4.1 cm W x 1.8 cm D) (Depth excludes connectors, height excludes mounting tabs.)
Product weight 0.2 lbs (0.1 kg) Vibration ISTA 1A in carton (International Safe Transit Association) Listings UL, CUL Compliances CE, FCC Class A, VCCI, AS/NZS, ICES MTBF 30,000 hours
N All nominal levels are at ± 10%
N Specifications are subject to change without notice.


Extron PMK 450 Low Profile Multi-Product Pole Mount Kit weight 2.5 lbs (1.2 kg)
Extron PMP 6 6” Projector Mount Pole weight 1.0 lbs (0.5 kg)
Extron Power Supply weight 0.8 lbs (0.4 kg)
Extron UPB 25 Universal Projector Mounting Bracket weight 3.7 lbs (1.7 kg)
Total weight (without projector)* 16-18 lbs (7.3-8.2 kg)
* Projector weight must not exceed 25 lbs (11.3 kg)
2-33 PoleVault Systems Installation • Installation - Reference Information



Stage One — Install the Screen and Projector.
c Mark the screen location (page 2-3).
c Install projector to verify location (page 2-3).
c Verify the image location (page 2-4).
c Cut the ceiling tile (page 2-5).
c Finish projector ceiling mount installation (page 2-5).
c Secure the projector ceiling mount to the ceiling (page 2-6).
c Install the screen (page 2-7).
Stage Two — Install the A/V Source Input wall plates and MLC 104 IP Plus.
c Install the mud rings (page 2-10).
c Pull cables (page 2-11).
c Install the wall plates (page 2-12).
c Install the MediaLink Controller (page 2-13).
Stage Three — Install the PV SI 3C LP Ceiling Speakers.
c Cut the ceiling tile (page 2-17).
c Install the speaker in the ceiling tile (page 2-17).
c Secure the speakers to the structural ceiling (page 2-18).
c Cable the speakers (page 2-18).
c Finish speaker installation (page 2-20).
Stage Four — Install the PMK 450 and the PVS 204SA.
c Pull the cables (page 2-22).
c Install the PMK 450 pole mount kit (page 2-22).
c Install the PVS 204SA switcher (page 2-23).
c Finish installing the pole mount kit (page 2-24).
Stage Five — Configuring the system.
c Configure the system (page 2-26).
c Test the system (page 2-28).
c Final installation (page 2-29).
Extron USA - West Headquarters
Extron USA - East
+800.633.9876 Inside USA / Canada Only
+800.3987.6673 Inside Europe Only
+800.7339.8766 Inside Asia Only
+400.883.1568 Inside China Only
+800.633.9876 Inside USA / Canada Only
+31.33.453.4040 +31.33.453.4050 FAX
+65.6383.4400 +65.6383.4664 FAX
+86.21.3760.1568 +86.21.3760.1566 FAX
+1.714.491.1500 +1.714.491.1517 FAX
© 2008 Extron Electronics. All rights reserved.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.