Instruction/ maintenance manual of the product LBI-38965 Ericsson
Go to page of 58
Mobile Communications EDACS BCU/CAL Billing Correlation Unit/ Centralized Activity Logger System and Installation Manual LBI-38965.
LBI-38965 2 TABLE OF CONTENTS 1. INTRODUCTION ............................................................................................................................................................. 4 1.1. BCU FUNCTIONAL DESCRIPTION .............
LBI-38965 3 TABLE OF CONTENTS (Cont.) 3.3. CAL OPERATIONAL SPECIFICATIONS ............................................................................................................ 16 3.3.1. System Manager Interface .................................
LBI-38965 4 1. INTRODUCTION This manual contains installation instructions, physical and functional descrip tions, specifications, and usage information for the Enhanced Digital Access Comm unications System (EDACS) Billing Correlation Unit and the Centralized Activity Logger (BCU/CAL).
LBI-38965 5 1.1. BCU FUNCTIONAL DESCRIPTION The main function of the BCU is to generate call d etail records (CDRs) to b e transferred to an external billing system f o r invoice gen eration.
LBI-38965 6 2. PHYSICAL DESCRIPTION AND COMPATIBILITY This section outlines the specifications, d epicts the physical architecture, and provides compatibility inform atio n for the BCU/CAL. Softw are for the BCU and the CA L are merged into on e software packag e.
LBI-38965 7 2.2. BCU/CAL ARCHITECTURE The BCU/CAL 's internal arch itecture is show n in Figure 2. The individual com ponents and their prim ary function s are outlined below. Figure 2 - BCU/CAL Architecture TVME712/M Transition Module Communications Module Hard Disk Floppy Disk From CAM Tape Drive SCSI Appl.
LBI-38965 8 The BCU/CAL is based on a VMEbus computing platform with the following components: CPU Technico TVME 147 single-board computer based on a 68030 microprocessor • Supports BCU/CAL applicat.
LBI-38965 9 2.3. COMPATIBILITY The BCU/CAL software is compatible with the following IMC and System Manager versions: • IMC Software V4.01 and later • IMC CAM Controller Board (P/N 19D903299P3) • Networks/Data VME Controller ROM V1.03 • MicroVax System Manager Software V3.
LBI-38965 10 3. SPECIFICATIONS 3.1. COMMON BCU AND CAL OPERATIONAL SPECIFICATIONS 3.1.1. EDACS System Interface The BCU/CA L interfaces to EDACS v ia a full duplex port supporting hi gh-level data link con trol (HDLC) protocol.
LBI-38965 11 3.2.2. Billing Architecture The EDACS billing system architecture is sho w n in Figure 3 . Each IMC is connected to a BCU/CAL via a high-speed serial communications link using HDLC protocol. Figure 3 - Billing Architecture 3.2.3. BCU Operation Overview Each RF system sends all call information to the IMC via the do w nlink.
LBI-38965 12 3.2.3.1. RF Channel Usage (Air Time) The basic unit of RF channel usage for billing purposes is a channel assignment. One or more w orking RF channels is assigned in response to a request from a subscriber unit (mobile radio, data term inal, etc.
LBI-38965 13 Channel assignment and channel drop messages contain the following information: • Date and time of event to the nearest tenth of a second • Type of event (i.e., assignment or drop) • Call type (individual clear voice, group clear voice, individual digital voice, group digital voice, data, etc.
LBI-38965 14 The thre e configuration files can b e created by running BCS o n a BCU/CAL used as a master. Then, these files can be copied to the appropriate directory (1.2/cnfg) on a target BCU, and the target will assume the sam e configuration values.
LBI-38965 15 3.2.3.10. Call Processing This section contains specifications on the BCU's call processing capability. CDR Processing A record of each conversation is maintain ed by the sy stem. A conversation is a collection of calls detailed by RARs that have been correlated based u pon call participants and caller pseudo hang time.
LBI-38965 16 3.3. CAL OPERATIONAL SPECIFICATIONS This section outlines the sp ecifications that are unique to the CAL personality. Ref er to Figure 4 for the CAL architecture.
LBI-38965 17 3.3.3. CAL Operation Overview As new RA Rs enter the system , they are dispatched to an appropriate site h andler which ref o rm ats and queues the data. When the nu mber of activity records queued exceeds a threshold valu e obtained from the Sy stem Manager at startu p, a download request is sent to the System Manager.
LBI-38965 18 4. INSTALLATION 4.1. HARDWARE INSTALLATION CAUTION Turn off the power before removing or installing VMEbus boards. Removing or reinstalling the bo ards while the po wer is on will damage the boards. This section describ es the phy sical installation o f the B C U/CAL.
LBI-38965 19 If the B CU/CAL is being connected to a netw o rk, plug a MAU (either coaxial or twisted pair) into the 15-pin female connector labeled "ETHERNET" on the TVME-712/M transition m odule on the rear of the BCU/C AL enclosure and attach the MA U to the netw ork.
LBI-38965 20 The following tab le sum marizes the co nfiguration files contained on Installation Diskette 4. These files are provided in template form , and should be m odified to suit customer- specific requiremen ts. T he files are in MS-DOS format, and may be edited with any ASCII text editor.
LBI-38965 21 Network routes are specified in the following form: type destination_ip gateway gateway_ip Table 4 - ROUTES.DAT File Parameters Parameter Meaning type Keyword for the type of route being added, either host or network . destination_ip IP address of the destination host or network, in Internet dotted-decimal notation.
LBI-38965 22 Export entries are specified in the following form: directory client_ip Table 5 - EXPORTS.DAT File Parameters Parameter Meaning directory Directory structure(s) to be exported. Must be a fully specified, valid directory on the BCU/CAL system disk (volume 1.
LBI-38965 23 Table 6 - CAL.DAT File Parameters Parameter Meaning SITE. ss .PASSWD Specifies the System Manager passw ord to be used for logins to /from this site. system_manager_passw ord m ust match the associated value prog rammed on th e System Manager for the site specified by ss .
LBI-38965 24 4.2.2. Initial Installation The followin g section discusses softw are installation on a new BCU/CAL. An ex ample of the expected term inal display during this sequence is also pro vided.
LBI-38965 25 INSTALLATION 1. Insert Installation Diskette 1 into the BCU/CAL floppy disk drive. 2. Apply unit pow er, and observe th e user console. The rem ainder of the instal lation is provided by way of example. Actual observed output may be slightly different.
LBI-38965 26 USER ACTION: Remove Installation Diskette 2. Insert Installation Diskette 3. Press the Enter key. <LOADER> Floppy disk has been mounted. Scanning floppy disk for BCU/CAL installation files... Copying BC_B.SX to 01.02/loads/BC_B.SX..
LBI-38965 27 ************************************************************** * Welcome to the EDACS BCU/CAL. * * * * Copyright (C) Ericsson GE Mobile Communications * * Mountain View Road * * Lynchburg.
LBI-38965 28 USER INFORMATION: Enter “ls” to observe the root lev el directory files a nd subdirectories w hich w ere created during the software installation process.
LBI-38965 29 Offload time = 00:00:00 Tape logging = Off CDR archive(s) lifetime = 7 IMC time synchronization = Off RAR activity logging = Off RAR maximum file records = 10000 System ID = 0 Node ID = 0 NIM slot = 0 PIM slot = 0 USER ACTION: To define the IMC NIM slot, execute the following com mand.
LBI-38965 30 <LOADER> Loading file 01.02/loads/BC_A.SX from the hard disk... * <LOADER> First load complete. 393126 bytes loaded. <LOADER> Loading file 01.02/loads/BC_B.SX from the hard disk... * <LOADER> Second load complete. 55692 bytes loaded.
LBI-38965 31 4.2.3. Software Upgrades Softw are upgrades are similar to th e initial installation procedu re discussed above. Each time the BC U/CAL boots, it will check to determ ine w hether a floppy diskette is installed. If a diskette is present, it w ill be scanned to check w hether any BCU/CAL installation files are present.
LBI-38965 32 For each site defined in the CAL.DAT file, configure the associated port on the terminal server as follows: Server>> change port port_no access remote Server>> change port por.
LBI-38965 33 Configuration Tips If all 16 ports of a term inal server are needed for Sy stem Manag er interface, first conf igure 15 of them using a “dumb” termin al connected to port 1. Port 1 (con figuration port) m ay then be re- assigned to a remote port, accessible via a teln et connection.
.
LBI-38965 A-1 APPENDIX A EDACS BILLING (CDR) FORMAT.
LBI-38965 A-2 This appendix defines the EDA CS call detail record (CDR) format f o r the collection of system reso urce usage data in a multisite trunked radio system .
LBI-38965 A-3 5. RECORD LAYOUT 5.1. SINGLE-SITE CALLS The followin g diagram show s the layout of the fields in a basic CDR for a single- site call. The top row sh ows the field name and num b er, the middle row shows the subfield nam e and letter, if ap plicab le, and the b otto m row shows the byte offset within the record.
LBI-38965 A-4 5.4. CALCULATING THE NUMBER OF BYTES IN A CDR Note that th e final linefeed character w hich termin ates the record is not shown in these diagrams. The actual n umber of bytes in a CDR is calculated by adding 2 to the offset of the final byte.
LBI-38965 A-5 6. CALL TYPE DEFINITIONS Table A.2 contains the ty pical values of the call ty pe (CDR field 6). Note that many call types are invalid, and most call types are valid only in conjunction with particular record types (CDR field 1).
LBI-38965 A-6 Table A.2 - Call Types (Cont.) Call Type Description Valid with Hex Decimal Rec. Type 45 69 Group, Digital Voice, System All Call, TX Trunked 00 46-48 70-72 **** Invalid Call Type **** 4.
LBI-38965 A-7 Call Type Bit Fields The call ty pe values h ave been selected so that individu al attributes of the call type m ay be associated w ith single- or double-bit fields w ithin the call ty pe byte. (The call type byte is the 8-bit value represented by the ASCII encoded, 2-digit hexadecimal number in the CDR call type field.
LBI-38965 A-8 7. CDR FILE TOPICS CDR files are located in the 1.2/cdr directory. All closed CDR files are named t dddhhmm. CDR, where ddd = Day of the year the record was created (001 to 366). hh = Hour of the day the record was created (00 to 23). mm = Minute of the hour the record was created (00 to 59).
LBI-38965 B-1 APPENDIX B PHYSICAL CONFIGURATION DETAILS.
LBI-38965 B-2 This appendix contains information about jumper settings and cable pinouts for the BCU/CAL. 1. JUMPER SETTINGS Jumper settings for the BCU/CAL components are shown on the pages listed below: Figure Page B.1 TVME 147SA1 Single-Board Computer .
LBI-38965 B-3 J1 J2 2 * AM27C040 U22 U30 Factory Set P1 P2 J5 J6 J3 System Controller Factory Set Serial Port 4 J8 J9 J7 Figure B.1 - TVME 147SA1 Single-Board Computer.
LBI-38965 B-4 Terminators Removed Figure B.2 - TVME 712/M Transition Module (Terminators Installed) Figure B.3 - TVME 147P2 Adapter Board.
LBI-38965 B-5 Figure B.4 - fv5310 Main Board.
LBI-38965 B-6 Figure B.5 - fv5310 Mezzanine Card PORT 0: DTE WITH DCE PROVIDING RX AND TX CLOCKS *IMC/CAM INTERFACE.
LBI-38965 B-7 J6 J7 J5 0 1 2 3 4 0 1 2 3 4 SCSI Connector RN2 RN1 (Terminators Removed) Parity SCSI ID = 2 (Factory Set) Motor start on power-up Figure B.
LBI-38965 B-8 Pwr SCSI Conn. Factory Set Jumpers RA2 RA1 TEAC FD235HS-711 ID2 ID1 ID0 SCSI ID = 1 (Terminators Removed) Figure B.7 - Teac FD235HS-711 Floppy Disk 1 2 3 4 5 6 7 8 SW1 JP6 JP4 RD2 RD1 PWR (Terminators Removed) SCSI Connector ON SCSI ID = 3 Self-Test Reserved DDS Pass-Through (Compression Off) Parity On SCSI Mode (SCSI-1) OFF Figure B.
LBI-38965 B-9 2. CABLE PINOUTS BCU/CAL Internal Wiring - VME P2 Backplane connector (of WANServer card) to DB-25 connectors on backplate Table B.1 - WANServer Port 0 Table B.
LBI-38965 B-10 Table B.3 - WANServer Port 2 Table B.4 - WANServer Port 3 VME P2 Connector DB-25F Connector Signal Name Function A-18 02 XMT-P Transmit Data C-19 14 XMT-N A-17 03 RCV-P Receive Data C-1.
LBI-38965 B-11 Table B.5 - BCU/CAL HDLC Loopback Cable Specification DB-25M Connector M/W BCU/CAL Port 1 DB-25M Connector M/W BCU/CAL Port 0 Signal Name Function 02 03 XMT-P Transmit Data 14 16 XMT-N .
LBI-38965 B-12 2 3 9X PI N 1 PI N 13 PI N 14 PI N 25 5 1 PI N 1 TBD .7 5 NOT ES: 1 . F ABRI CATE CABL E T O L ENGT H I NDI CATED. NOTE CO NNECTO R O RI ENTAT I O N CAREF ULL Y.
LBI-38965 B-13 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J15 J16 420 3 8 40 G 1 TER M I N A L S E R V ER 1 420384 0 G1 TER M I N A L S E RV ER 2 1 J33 P O R T 1 PO R T 2 P O R T 3 P O R T 4 PORT .
LBI-38965 B-14 Co mpu t e r Te rm i n a l ASCI I Ke y b o a r d A7 P 2 A 7 IN M A C H 3 5 3 -2 A7P1 PORT 1/ CONSOLE SE RI AL POR T 3 SE R I AL PO R T 2 SERI AL POR T 4 SC SI I N TER F AC E ETH ERN E T.
LBI-38965 C-1 APPENDIX C FAULT TOLERANCE.
LBI-38965 C-2 Figure C.1 shows the architecture for a fault tolerant EDACS billing system. RF System Console Terminal MIM (Primary) MIM BCU BCU C A M C A M AREA IMC Console Terminal To StarGate Primary Downlink Backup Downlink (Backup) Figure C.
An important point after buying a device Ericsson LBI-38965 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ericsson LBI-38965 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ericsson LBI-38965 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ericsson LBI-38965 you will learn all the available features of the product, as well as information on its operation. The information that you get Ericsson LBI-38965 will certainly help you make a decision on the purchase.
If you already are a holder of Ericsson LBI-38965, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ericsson LBI-38965.
However, one of the most important roles played by the user manual is to help in solving problems with Ericsson LBI-38965. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ericsson LBI-38965 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center