LBI-38505A (Supercedes LBI-30025) T ABLE OF CONTENTS RF ASSEMBL Y , MIXER AND REFI L TE R BOARD . . . . . . . . . . . . . LBI-30 032 (DF110 7) OSCILLA TOR/MUL TIPLIE R BOARD . . . . . . . . . . . . . . . . . . . . LB I-30 029 (DF110 6) IF A UDIO AND SQUELCH BOARD .
Copyright © May 1990, Eri csson GE M obile C ommunications Inc. T ABLE OF CONTENTS Page SPECIFICA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION MASTR II Base Station, 406 to 512 mega hertz receivers are single co n version, superhe terodyn e FM recei vers design ed for one-th rough eight-freq uency op eration.
T o remove the IF Filter board from the radi o: 1. Remove the eight screws (E) holding the IF Filter bottom cov er . 2. Remove the six scre ws (F) holding the IF Filter top cover . 3. R e move the th ree screws (G) and the C onnector (H ), and care fully pus h do wn on the top of t he boar d to a void dama gi n g t he f ee dthrough ca pa cito rs .
FR ONT END ALIGNMENT EQUIPMENT REQUIRED 1. T est Set Mode ls 4EX3A11, 4EX8K12, or 20,000 ohms-per-V olt multimete r with a 1 V olt scale. 2. A 406-512 MHz signa l source. PRELIMIN AR Y CHECKS AND ADJUSTMENT S 1. Connect blac k plug from T est Set to Rece iver Centralized Met ering Jack J601, and red plug to system board met ering jack J905.
406-512 MHz MASTR II RECEIVER ICOM FREQ UENCY ADJUSTMENT First, check the frequency to determine if any adjustment is required. The frequency meas urement requires equipment with an absolute accurac y which is 5 to 10 times better than the tolerance to be maintained.
ALIGNMENT PR OCEDURES COMPLETE RECEIVER ALIGNMENT EQUIPMENT REQUIRED 1. T est Set Model s 4EX3A11, 4EX8K12, or 20,000 ohms-per V olt multi meter with a 1- V olt scal e. 2. An 11.2 MHz signal s ource (T est Set Model 4EX9A10). Al so a 406-512 MHz signal source with a one-inc h piece of insulated wire no la rger than .
TEST PR OCEDURES These T est Proc edures are desi gned to h elp yo u to ser vice a recei ver that is operating---but not proper ly . The problems e n- countered could be low po wer , poor sensiti vity , distortion, limiter not operating properly , and low gain.
TR OUBLESHOO TING PR OCEDURES TEST PR OCEDURES TEST PR OCEDURES STEP 2 USABLE SENSITIVITY (12 dB SIN AD) If STEP 1 checks out properly , measure the rece i ver sensiti vity as follows: A. Apply a 1 000 microvolt, on frequency signal mod ulated by 10 00 Hz with 3.
TR O UBLESHOO TING PROC EDURES SQUELCHED UNSQUEL CHED NOISE SQ OUTPUT U605-2 0.2 VDC 9 .9V CAS U605-1 0.1 VD C 9.9V RX MUTE U605-14 0.2 VDC 9 .9V R U S U605-13 0. 2 VDC 4.9 V SQ DISABLE SW . INPUT U606-1 0.2 VD C 9.9V A UDIO GA T E SW . CONTR OL U606-11 0.
TR O UBLESHOO TING PROC EDURES 406-512 MHz MASTR II RECEIVER LBI-38505 LBI-38505 10.
406-512 MHz MASTR II RECEIVER TR OUBLESHOO TING PR OCEDURES LBI-38505 LBI-38505 11.
An important point after buying a device Ericsson LBI-38505A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ericsson LBI-38505A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ericsson LBI-38505A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ericsson LBI-38505A you will learn all the available features of the product, as well as information on its operation. The information that you get Ericsson LBI-38505A will certainly help you make a decision on the purchase.
If you already are a holder of Ericsson LBI-38505A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ericsson LBI-38505A.
However, one of the most important roles played by the user manual is to help in solving problems with Ericsson LBI-38505A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ericsson LBI-38505A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center