Display Attached Controller @E.Terminal for MC <Hardware> FEH300b Coverp.1Prefacep.2Safety Precautionsp.3Revisionsp.6Contentsp.7Section 1 Generalp.81-1 Overview of @E.Terminal for MCp.91-2 Appearancep.101-3 Typesp.111-4 System Compositionp.13Section 2 Specificationsp.142-1 Specificationsp.152-1-1 General specificationsp.152-1-2 Display unit specificationsp.16(1) Display unit specificationsp.16(2) Touch switch specificationsp.16(3) Function switch specificationsp.16(4) Interface specificationsp.17(5) Clock and backup memory specificationsp.17(6) Drawing environmentp.18(7) Display function specificationsp.18(8) Function performance specificationsp.192-1-3 Controller unit specificationsp.20(1) Application performance specificationsp.20(2) Specific system memoryp.212-2 Dimensions and Panel Cut-outp.222-2-1 External dimensions and panel cut-out dimensions for the NP5M0101-5H4p.222-2-2 External dimensions and panel cut-out dimensions for the NP5M0101-4H4p.232-2-3 External dimensions and panel cut-out dimensions for the NP5M0101-3H4p.242-3 Names and Functionsp.252-3-1 Display unitp.25(1) NP5M0101-5H4p.25(2) NP5M0101-4H4p.25(3) NP5M0101-3H4p.262-3-2 Controller unitp.282-4 Serial Connectorp.302-5 Modular Jack (MJ1 / MJ2)p.312-6 Dip Switchesp.32Section 3 Installationp.343-1 Mounting Procedurep.35(1) Mounting procedurep.35(2) Mounting anglep.353-2 Power Supply Cable Wiringp.36(1) Power supply cable wiringp.36(2) Groundingp.38Section 4 Inspection and Maintenancep.394-1 Inspection and Maintenancep.404-1-1 Daily inspectionp.404-1-2 Periodical inspectionp.404-2 Battery Replacementp.41(1) Battery specificationp.41(2) Precautionsp.41(3) How to replacement batteryp.414-3 Maintenance Servicesp.434-3-1 Ordering notesp.434-3-2 Free-of-charge warranty period and scope of warrantyp.434-3-3 Service costsp.43Appendix 1 About Project for @E.Terminal (No contents installed)p.44Back Coverp.46
Page 1 of the Epson FEH300b user manual — FEH300b
Page 1 · click to enlarge
Page 1

Display Attached Controller

@E.Terminal for MC

USER'S MANUAL

Hardware

FEH300b

Page 2 of the Epson FEH300b user manual — URL http://www.fesys.co.jp/eng/
Page 2 · click to enlarge
Page 2

Preface

This hardware edition of the user’s manual describes system composition, specifications, and handling of the @E.Terminal. In order to operate the hardware properly, please read this user’s manual carefully. When using modules or peripheral devices, be sure to read the corresponding user’s manuals listed below.

TitleManual No.Contents @E.Terminal for MC User's Manual <Function>FEH301Describes functions and the usage of motion control content for @E.Terminal for MC. V8 series Hardware Specifications2016NExHardware specifications and handling procedures of the MONITOUCH V8 series are explained. V8 series Reference Manual1055NExDescribes functions and the usage of the MONITOUCH V8 series. V series Macro Reference1056NExDescribes overview of the macro of the V-SFT version 5, the usage of the macro editor and contents of the macro commands. V8 series Introductory Manual1057NExDescribes basic operation of the MONITOUCH V8 series. V8 series Connection Manual2201NExThe connection and communication parameters for the V8 series and controllers are explained in detail. User's Manual Hardware, MICREX-SX series SPHFEH201Describes the system configuration, the specifications and operations of modules in the MICREX-SX series. User's Manual Instruction (Standard Loader), MICREX-SX seriesFEH588Describes the memory, language and system definitions of the MICREX-SX series. User's Manual SX-Programmer Standard <Reference>, MICREX-SX seriesFEH590Describes the menu and icon of the SX-Programmer Standard all of the operations of the SX-Programmer Standard. User's Manual Instruction (D300win), MICREX-SX seriesFEH200Describes the memory, language and system definitions of the MICREX-SX series. User's Manual D300win <Reference>, MICREX-SX seriesFEH257Describes the menu and icon of D300winV3 and all of the operations of D300winV3. FALDIC α series User's Manual, RYS-V TypeMHT258 (Eng)Describes the specifications and operations of FALDIC α series. ALPHA 5 series User's Manual, RYT-V TypeMEHT300Describes the specifications and operations of ALPHA 5 series.

In addition to the above manuals, the following Fuji Electric Systems Co., Ltd. site offers various manuals and technical documents associated with the @E.Terminal for MC.

URL http://www.fesys.co.jp/eng/

Notes

1. This manual may not be reproduced in whole or part in any form without prior written approval by the manufacturer. 2. The contents of this manual (including specifications) are subject to change without prior notice. 3. If you find any ambiguous or incorrect descriptions in this manual, please write them down (along with the manual No. shown on the cover) and contact FUJI.
Page 3 of the Epson FEH300b user manual — Warning
Page 3 · click to enlarge
Page 3

Safety Precautions

Be sure to read the “Safety Precautions” thoroughly before using the module. Here, the safety precaution items are classified into “Warning” and “Caution.”

Even some items indicated by “Caution” may also result in a serious accident.

Both safety instruction categories provide important information. Be sure to strictly observe these instructions.

Warning

◊Never use the output signal of @E.Terminal for operations that may threaten human life or damage the system, such

as signals used in case of emergency. Please design the system so that it can cope with the malfunctions of a touch switch. A malfunction of a touch switch will result in machine accident or damage. ◊Turn off the power supply when you set up the unit, connect new cables or perform maintenance or inspections.

Otherwise, electrical shock or damage may occur. ◊Never touch any terminals while the power is on. Otherwise, electric shock may occur. ◊You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Otherwise,

electric shock may occur. ◊The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, do not ingest the leaked

liquid crystal. If the liquid crystal spills on skin or clothing, use soap and wash off thoroughly. ◊Never disassemble, recharge, deform by pressure, short-circuit, reverse the polarity of the lithium battery, nor dispose

of the lithium battery in fire. Failure to follow these conditions will lead to explosion or ignition. ◊Never use a lithium battery that is deformed, leaks, or shows any other signs of abnormality. Failure to follow these

conditions will lead to explosion or ignition. ◊The power lamp flashes when the backlight is at the end of life or is faulty. However, the switches on the screen are

operable at this time. Do not touch the screen when the screen becomes dark and the power lamp flashes. Otherwise, a malfunction may occur and result in machine accident or damage.

Page 4 of the Epson FEH300b user manual — Caution
Page 4 · click to enlarge
Page 4

Safety Precautions

Caution

◊Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found.

Failure to do so may lead to fire, damage or malfunction. ◊For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile

installations, please consult your local distributor. ◊Operate (or store) @E.Terminal under the conditions indicated in this manual and related manuals. Failure to do so

could cause fire, malfunction, physical damage or deterioration. ◊Understand the following environmental limits for use and storage of @E.Terminal. Otherwise, fire or damage to the

unit may result. - Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding fluids or cutting oil can come into contact with the unit. - Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight. - Avoid locations where excessive dust, salt, and metallic particles are present. - Avoid installing the unit in a location where vibration or physical shock may be transmitted. ◊Equipment must be correctly mounted so that the main terminal of @E.Terminal will not be touched inadvertently.

Otherwise, an accident or electric shock may occur. ◊Check periodically that terminal screws on the power supply terminal block and fixtures are firmly tightened. Loosened

screws may result in fire or malfunction. ◊Tighten terminal screws on the power supply terminal block of display part equally to a torque of 0.8 N·m for the

NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, or 1.2 N·m for the NP5M0101-3H4/NP5N-0011-3H4. And tighten terminal screws on the power supply terminal block of the controller unit equally to a torque of 0.5 to 0.6 N·m. Improper tightening of screws may result in fire, malfunction, or trouble. ◊Tighten mounting screws on the unit equally to a torque of 0.5 to 0.7 N·m. Excessive tightening may distort the panel

surface. Loose tightening may cause @E.Terminal to come off, malfunction or be short-circuited. ◊@E.Terminal has a glass screen. Do not drop or give physical shock to the unit. Otherwise, the screen may be

damaged. ◊Connect the cables correctly to the terminals of @E.Terminal in accordance with the specified voltage and wattage.

Over-voltage, over-wattage, or incorrect cable connection could cause fire, malfunction or damage to the unit. ◊Be sure to establish a ground of @E.Terminal. The FG terminal must be used exclusively for the unit with the level of

grounding resistance less than 100Ω. Otherwise, electric shock or a fire may occur. ◊Prevent any conductive particles from entering into @E.Terminal. Failure to do so may lead to fire, damage, or

malfunction. ◊After wiring is finished, remove the paper used as a dust cover before starting to operate @E.Terminal. Operation with

the cover attached may result in accident, fire, malfunction, or trouble. ◊Do not attempt to repair @E.Terminal at your site. Ask us or the designated contractor for repair. ◊Do not repair, disassemble or modify @E.Terminal. We are not responsible for any damages resulting from repair,

disassembly or modification of @E.Terminal that was performed by an unauthorized person. ◊Do not use a sharp-pointed tool when pressing a touch switch. Doing so may damage the screen. Doing so may

damage the screen. ◊Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspection. ◊Lithium batteries contain combustible material such as lithium or organic solvent. Mishandling may cause heat,

explosion or ignition resulting in fire or injury. Read related manuals carefully and handle the lithium battery correctly as instructed. ◊When using @E.Terminal that has analog switch resolution with resistance film, do not press two or more points on the

screen at the same time. If two or more positions are pressed at the same time, the switch located between the pressed positions activates. ◊Take safety precautions during such operations as setting change during running, forced output, start, and stop.

Any misoperation may cause unexpected machine motions, resulting in machine accident or damage. ◊In facilities where a failure of @E.Terminal could lead to accident threatening human life or other serious damage, be

sure that the facilities are equipped with adequate safeguards. ◊At the time of disposal, @E.Terminal must be treated as industrial waste. ◊Before touching @E.Terminal, discharge static electricity from your body by touching grounded metal. Excessive static

electricity may cause malfunction or trouble. ◊The LED lamp on the CF card interface cover illuminates in red when the power is supplied to the CF card.

Never remove the CF card or turn off the power of @E.Terminal while the LED lamp is lit. Doing so may destroy the data on the CF card. Check that the LED lamp has gone off before removing the CF card or turning off the power of @E.Terminal.

Page 5 of the Epson FEH300b user manual — [Notes on LCD]
Page 5 · click to enlarge
Page 5

Safety Precautions

[General Notes]

  • Never bundle control cables nor input/output cables with high-voltage and large-current carrying cables such as power supply cables. Keep these cables at least 200 mm away from the high-voltage and large-current carrying cables. Otherwise, malfunction may occur due to noise.
  • When using @E.Terminal in an environment where a source of high-frequency noise is present, it is recommended that the FG shielded cable (communication cable) be grounded at its ends. However, the cable may be grounded only at one end if this is necessary due to unstable communication conditions or for any other reason.
  • Plug connectors or sockets of @E.Terminal in the correct orientation. Failure to do so may lead to damage or malfunction.
  • If a LAN cable is inserted into the MJ1 or MJ2 connector on @E.Terminal, the counterpart device may be damaged. Check the indication on the unit and insert a cable into the correct position.
  • Do not use thinners for cleaning because they may discolor @E.Terminal surface. Use alcohol or benzine commercially available.
  • If a data receive error occurs when @E.Terminal and the counterpart (PLC, temperature controller, etc.) are started at the same time, read the manual for the counterpart unit and remove the error correctly.
  • Avoid discharging static electricity on the mounting panel of @E.Terminal. Static charges can damage the unit and cause malfunctions. Otherwise, malfunction may occur due to noise.
  • Avoid prolonged display of any fixed pattern. Due to the characteristics of the liquid crystal display, an afterimage may occur. If a prolonged display of a fixed pattern is expected, use the auto OFF function of the backlight.

[Notes on LCD]

  • The response time, brightness and colors of @E.Terminal may be affected by the ambient temperature.
  • Tiny spots (dark or luminescent) may appear on the display due to the liquid crystal characteristics.
  • There are variations in brightness and colors on each unit.
  • Cold cathode tubes are incorporated into the LCD display for backlights. Optical properties (brightness, irregular colors, etc.) may change in a low-temperature environment or over time of operation.
Page 6 of the Epson FEH300b user manual — Revisions
Page 6 · click to enlarge
Page 6

Revisions

*Manual No. is shown on the cover.

Printed on*Manual No.Revision contents Aug. 2008 Nov. 2008 Dec. 2008FEH300 FEH300a FEH300bFirst edition • Display part is changed from UG40 series to V8 series. • Accessory "Noise filter" is eliminated from controller hardware version "03" or later. @E.Terminal (No contents installed) was added.
Page 7 of the Epson FEH300b user manual — Table of Contents
Page 7 · Contents
Contents

Contents

Display Attached Controller @E.Terminal for MC <Hardware> FEH300b Coverp.1Prefacep.2Safety Precautionsp.3Revisionsp.6Contentsp.7Section 1 Generalp.81-1 Overview of @E.Terminal for MCp.91-2 Appearancep.101-3 Typesp.111-4 System Compositionp.13Section 2 Specificationsp.142-1 Specificationsp.152-1-1 General specificationsp.152-1-2 Display unit specificationsp.16(1) Display unit specificationsp.16(2) Touch switch specificationsp.16(3) Function switch specificationsp.16(4) Interface specificationsp.17(5) Clock and backup memory specificationsp.17(6) Drawing environmentp.18(7) Display function specificationsp.18(8) Function performance specificationsp.192-1-3 Controller unit specificationsp.20(1) Application performance specificationsp.20(2) Specific system memoryp.212-2 Dimensions and Panel Cut-outp.222-2-1 External dimensions and panel cut-out dimensions for the NP5M0101-5H4p.222-2-2 External dimensions and panel cut-out dimensions for the NP5M0101-4H4p.232-2-3 External dimensions and panel cut-out dimensions for the NP5M0101-3H4p.242-3 Names and Functionsp.252-3-1 Display unitp.25(1) NP5M0101-5H4p.25(2) NP5M0101-4H4p.25(3) NP5M0101-3H4p.262-3-2 Controller unitp.282-4 Serial Connectorp.302-5 Modular Jack (MJ1 / MJ2)p.312-6 Dip Switchesp.32Section 3 Installationp.343-1 Mounting Procedurep.35(1) Mounting procedurep.35(2) Mounting anglep.353-2 Power Supply Cable Wiringp.36(1) Power supply cable wiringp.36(2) Groundingp.38Section 4 Inspection and Maintenancep.394-1 Inspection and Maintenancep.404-1-1 Daily inspectionp.404-1-2 Periodical inspectionp.404-2 Battery Replacementp.41(1) Battery specificationp.41(2) Precautionsp.41(3) How to replacement batteryp.414-3 Maintenance Servicesp.434-3-1 Ordering notesp.434-3-2 Free-of-charge warranty period and scope of warrantyp.434-3-3 Service costsp.43Appendix 1 About Project for @E.Terminal (No contents installed)p.44Back Coverp.46
Page 8 of the Epson FEH300b user manual — 1-1 Overview of @E.Terminal for MC............................................................................... 1-1
Page 8 · click to enlarge
Page 8

Section 1 General

1-1 Overview of @E.Terminal for MC 1-1

1-2 Appearance ................................................................................................................. 1-2

1-3 Types ............................................................................................................................ 1-3

1-4 System Composition .................................................................................................. 1-5

Page

Page 9 of the Epson FEH300b user manual — Section 1 General 1-1 Overview of @E.Terminal for MC
Page 9 · click to enlarge
Page 9

Section 1 General 1-1 Overview of @E.Terminal for MC

The @E.Terminal for MC Display Attached Controller is an all-in-one programmable operation display and motion controller.

Features:

1) The guidance function of the display screen allows you to easily set up parameters and positioning data previously set up by a dedicated machine. Also, it enables easy equipment maintenance. 2) The SX bus allows one-touch connection of up to eight servo amplifiers (axes) (FALDIC-α and APLHA5 VS type), minimizing the need for wires. 3) The upper level controller can be connected by Ethernet and the like. 4) The lineup includes three different display screen sizes. 8 inch, 10 inch and 12 inch models are available. 5) The content corresponding to motion is supplied in the standard package. Content for PTP control and synchronous control (ratio synchronization, cycle synchronization, flying shear, and rotary shear) are provided.

Ethernet, ctc.

Epson FEH300b — Section 1 General 1-1 Overview of @E.Terminal for MC diagram (page 9)
Fig. 1 · Section 1 General 1-1 Overview of @E.Terminal for MC

@E.Terminal for MC

  • Contents for motion control
  • Screen data
  • Controller built-in software

Motion functions (Setting/Display) · SX bus Note)

Page 10 of the Epson FEH300b user manual — Front
Page 10 · click to enlarge
Page 10

1-2 Appearance

@E.Terminal for MC is composed of a programmable operation display (the display unit) and a controller unit attached to the back of the display unit. The controller unit is attached with screws to the connector area of the communication unit at the back of the display unit, similar to the way in which the communication unit is attached.

Type 12

Epson FEH300b — Type 12 diagram (page 10)
Fig. 2 · Type 12
Epson FEH300b — Type 12 diagram (page 10)
Fig. 3 · Type 12

Type 10

Epson FEH300b — Type 10 diagram (page 10)
Fig. 4 · Type 10

Type 8

Epson FEH300b — Type 8 diagram (page 10)
Fig. 5 · Type 8

Front

Back

Page 11 of the Epson FEH300b user manual — 1-3 Types
Page 11 · click to enlarge
Page 11

1-3 Types

  • @E.Terminal for MC
Product typesDisplay sizeSpecifications NP5M0101-5H412.1 inches• TFT color, 800 x 600 dots, DC power supply • Controller unit • Contents of the motion control (Screen data, built in software in the controller) NP5M0101-4H410.4 inches NP5M0101-3H48.4 inches
  • @E.Terminal (No contents installed)
Product typesDisplay sizeSpecifications NP5N0011-5H412.1 inches• TFT color, 800 x 600 dots, DC power supply • Controller unit • No contents installed NP5N0011-4H410.4 inches NP5N0011-3H48.4 inches
  • Accessories
Product typesNamesQuantity NP5M0101-5H4 NP5M0101-4H4 NP5M0101-3H4 NP5N0011-5H4 NP5N0011-4H4 NP5N0011-3H4Instruction Manual1 Backup CD of the @E.Terminal for MC Note1)1 SX bus terminating plug2 Screw driver1 Fixture4 Binder for USB cable (Only NP5M0101-3H4/NP5N0011-3H4)1 USB cable cramp for port A/B (Only NP5M0101-5H4/4H4, NP5N0011-5H4/4H4)2 M3 x 8 screw for USB cable cramp (Only NP5M0101-5H4/4H4, NP5N0011-5H4/4H4)2 Noise filter Note2)1
  • Screen drawing tools
NamesTypesSpecifications Configuration software: English versionV-SFT-5Screen editor: Windows98SE/NT4.0/Me/2000/XP/XP64Edition/Vista32-bit compatible Screen data transfer cableV-CP3m, Used for connection between the V8 series and a personal computer.
  • Programming support tool for controller
NamesTypesSpecifications SX-Programmer StandardNP4H-SWNProgramming support tool SX-Programmer Standard, Standard expansion FB, Windows95/98/ME/2000/XP/NT4.0 SX-Programmer Expert (D300win)NP4H-SEDBV3IEC61131-3 based on Programming support tool D300winV3, Standard expansion FB, Windows2000/XP/NT4.0 Support tool cableNW0H-CNVRS-232C/RS-485 converter for the programming support tool for AT compatible personal computer NW0H-CA3Support tool connection cable (Used to combined the NW0H-CNV)
Page 12 of the Epson FEH300b user manual — 1-3 Types
Page 12 · click to enlarge
Page 12

1-3 Types

  • Auxiliaries and others
NamesTypesSpecifications Battery for display unitV7-BTReplacement lithium primary battery for the V8 series V812-FL V810-FL V808S-FL NP8P-BT NP8B-BP NP1C-P3 NP1C-P6 NP1C-P8 NP1C-02 NP1C-05 NP1C-10 NP1C-15 NP1C-25

* For information about peripheral accessories of the display unit not documented in this manual, please refer to “V8 series Hardware Specifications (2016NEx)”.

Page 13 of the Epson FEH300b user manual — "NW0H-CNV + NW0H-CA3"
Page 13 · click to enlarge
Page 13

1-4 System Composition

The following illustration shows the system composition of @E.Terminal for MC.

LAN/CN1/MJ1/MJ2

USB-B

Up to 8 servos and I/O terminals each can be connected.

Epson FEH300b — LAN/CN1/MJ1/MJ2 diagram (page 13)
Fig. 6

MJ1/MJ2

"V-CP"

Screen editor "V-SFT-5" (V5.3.0.0 or later)

External PG (only No. 1 axis)

@E.Terminal for MC

FALDIC ALPHA5 FALDIC - α

[No. 1 axis] SX bus station No.: "201"

"NW0H-CNV + NW0H-CA3"

or commercially available USB cable

[No. 2 axis] SX bus station No.: "202"

FALDIC ALPHA5 FALDIC - α

Programming support tool SX-Programmer Standard "NP4H-SWN" (V2.3.5.1 or later) SX-Programmer Expert (D300win) "NP4H-SEDBV3" (V3.4.4.0 or later)

[No. 8 axis] SX bus station No.: "208"

FALDIC ALPHA5 FALDIC - α

Starting up signal etc.

I/O terminal Input 8 points/ Output 8 points (NR1SW-16T65DT)

SX bus station No.: "221"

RDY etc.

FALDIC-α (RYS***S3-VSS, RYS***M3-VSK) FALDIC ALPHA5 (RYT*** 5-VS )

I/O terminal Input 8 points/ Output 8 points (NR1SW-16T65DT)

SX bus station No.: "228"

PLC/general purpose computer · Ethernet/RS-232C or RS-485 · SX bus

Page 14 of the Epson FEH300b user manual — 2-4 Serial Connector ....................................................................................................... 2-16
Page 14 · click to enlarge
Page 14

Section 2 Specifications

2-1 Specifications 2-1

2-1-1 General specifications 2-1

2-1-2 Display unit specifications 2-2

(1) Display unit specifications 2-2 (2) Touch switch specifications 2-2 (3) Function switch specifications 2-2 (4) Interface specifications 2-3 (5) Clock and backup memory specifications 2-3 (6) Drawing environment 2-4 (7) Display function specifications 2-4 (8) Function performance specifications 2-5

2-1-3 Controller unit specifications 2-6

(1) Application performance specifications 2-6 (2) Specific system memory 2-7

2-2 Dimensions and Panel Cut-out 2-8

2-2-1 External dimensions and panel cut-out dimensions for the

NP5M0101-5H4/NP5N0011-5H4 2-8

2-2-2 External dimensions and panel cut-out dimensions for the

NP5M0101-4H4/NP5N0011-4H4 2-9

2-2-3 External dimensions and panel cut-out dimensions for the

NP5M0101-3H4/NP5N0011-3H4 2-10

2-3 Names and Functions............................................................................................... 2-11

2-3-1 Display unit 2-11

(1) NP5M0101-5H4/NP5N0011-5H4 2-11 (2) NP5M0101-4H4/NP5N0011-4H4 2-11 (3) NP5M0101-3H4/NP5N0011-3H4 2-12

2-3-2 Controller unit 2-14

2-4 Serial Connector 2-16

2-5 Modular Jack (MJ1 / MJ2)......................................................................................... 2-17

2-6 Dip Switches.............................................................................................................. 2-18

Page

Page 15 of the Epson FEH300b user manual — NP5M0101-4H4 NP5N0011-4H4
Page 15 · click to enlarge
Page 15

Section 2 Specifications

2-1 Specifications

2-1-1 General specifications

Items Specifications NP5M0101-5H4 NP5N0011-5H4

NP5M0101-3H4 NP5N0011-3H4 Physical environmental conditions

NP5M0101-4H4 NP5N0011-4H4

0 to +50 °C

-10 to +60 °C

85 % RH or less (Without dew condensation, max. wet-bulb temperature: 39 °C or less) Operational altitude 2000 m or less above sea level (Transport condition: 70 kPa or more) Operational atmosphere No corrosive gas, no excessive dust, no conductive dust contamination, and not stained with organic solvents. Pollution degree 2 (Note1) Mechanical working conditions

Vibration resistance Half-amplitude: 0.075 mm, acceleration: 9.8 m/s2, X, Y, Z: 3 directions for one hour Shock resistance Peak acceleration: 147 m/s2, X, Y, Z: 3 directions three times each Electrical working conditions

Noise resistance Rising time: 1 ns, pulse width: 1 µs, Noise voltage: 1.5 kVp-p (Measured by using a noise simulator.) Static electricity discharge resistance

Contact±4 kV, air: ±8 kV

Power supply Rated input voltage 24V DC (Note2) Rated voltage (tolerance) 24V DC ±10% Permissible momentary power failure

1 ms or less

power supply consumption (Max. rated)

42 W or less 37 W or less 35 W or less

Rush current 170 A or less Input terminal block

Display unit Terminal block screwM3.5 - (Connection to the

controller unit) Tightening torque: 0.8 N·m Controller unit Terminal block screw: M3 Tightening torque: 0.5 to 0.6 N·m Dielectric strength 500 V AC 1 minute (Between external terminals and frame ground) Isolation resistance 500 V DC, 5 MΩor more Dimensions W x H x D (mm) 326.4 x 259.6 x 99.0 303.8 x 231.0 x 99.0 233.0 x 178.0 x 96.0 Mass Approx. 3.5 kg Approx. 3.1 kg Approx. 2.1 kg

conductivity occurs due to condensation. Note 2) Use 24V DC power supply which comply to UL standard Class2 insulation.

  • Installation specifications

Item Specifications Grounding Less than 100Ω, FG/SG separated Protection structure Front panel (Note 1) Compliant with IP65 (When using waterproof gasket) (Note 2) Cooling system Cooling naturally Structure Inserted in a mounting panel Appropriate mounting panel thickness 1.5 to 5 mm

unit compliant with IP65. The strength differs depending on the material of the mounting panel. Check the environment where the @E.Terminal is used.

Operational ambient temperature · Storage ambient temperature · Operational ambient humidity

Page 16 of the Epson FEH300b user manual — NP5M0101-4H4 NP5N0011-4H4
Page 16 · click to enlarge
Page 16

2-1 Specifications

2-1-2 Display unit specifications

(1) Display unit specifications

NP5M0101-3H4 NP5N0011-3H4 Display device TFT color Display size 12.1-inch 10.4-inch 8.4-inch Colors 65,536 colors (without blinks) / 32,768 colors (with blinks) Display resolution (W x H) 800 x 600 dots Dot pitch (W x H) 0.3075 x 0.3075 mm 0.264 x 0.264 mm 0.2135 x 0.213 mm Backlight Cold cathode tube Backlight life (average life of backlight only)

NP5M0101-4H4 NP5N0011-4H4

Approx. 50,000 hours (at the normal temperature of 25° C)

Backlight auto OFF function Always ON, random setting Brightness adjustment Function switch: 3 levels / Macro: 128 levels Surface sheet material Polycarbonate, 0.3 mm thick POWER lamp ON: Normal (green) Blink: Backlight error

(2) Touch switch specifications

Item Specifications Method Analog resistance film type Number of switches 1024 x 1024 Mechanical life One million activations or more Surface treatment Hard-coated, anti-glare treatment 5 %

(3) Function switch specifications

Item Specifications Number of function switches 8 pcs. Method Matrix resistance film type Mechanical life One million activations or more

Item NP5M0101-5H4 NP5N0011-5H4

Page 17 of the Epson FEH300b user manual — USB-A USB-B
Page 17 · click to enlarge
Page 17

2-1 Specifications

Item Specifications D-sub 9-pin (CN1) Applicable standards

RS-232C, RS-422/485

Synchronization Asynchronous type Data length 7- or 8-bit Parity None, odd, even Stop bit 1- or 2-bit Baud rate 4800, 9600, 19200, 38400, 57600, 76800, 115.2kbps (187500 bps for MPI connection (Note)) Applications PLC, temperature controller, barcode reader, etc. Modular jack 8-pin (MJ1/MJ2)

RS-232C, RS-485 (2-wire connection)

Applications Screen data transfer (MJ1), PLC, temperature controller, CREC, barcode reader, V-I/O, Multi-link 2, V-Link, etc. USB connector (USB-A/B)

Compliant with USB version 1.1

USB-A USB-B

Baud rate Low speed: 1.5 Mbps, full speed: 12 Mbps Applications Printer (EPSON PM series), CF card reader/writer Applicable standards

Compliant with USB version 1.1

Baud rate Low speed: 1.5 Mbps, full speed: 12 Mbps Applications Screen data transfer, PictBridge-compatible printer Ethernet port 100BASE-TX/ 10BASE-T (LAN)

Compliant with IEEE802.3u (100BASE-TX), IEEE802.3 (10BASE-T)

Baud rate 100 Mbps, 10 Mbps Recommended cable

100 ΩUTP (unshielded twist-pair cable), category 5, max. 100 m long

Applications PLC connection, etc. CF card interface Compliant with CompactFlashTM

Extensional communication port (CN5)

Controller unit connection (The communication unit is not connectable.) Optional unit port (CN7) RGB input/output, video, sound (The optional unit "GU-xx" is necessary.)

(5) Clock and backup memory specifications

Item Specifications Battery specification Coin-type lithium primary cell Backup memory SRAM 512 kbytes Backup period Approx. 5 years (Ambient temperature at 25 °C) Battery voltage drop detection Provided (Internal memory of $s167 allocated) Calendar accuracy Monthly deviation ±90 s (Ambient temperature at 25 °C) (Note)

(backup with battery). Depending on the ambient temperature, the calendar may lose 356 seconds or advance 189 seconds in a month at the maximum. Correct the clock periodically.

Show 4 more labels / short text on this page
(4) Interface specifications · Applicable standards · Applicable standards · Applicable standards
Page 18 of the Epson FEH300b user manual — 2-1 Specifications
Page 18 · click to enlarge
Page 18

2-1 Specifications

Item Specifications Drawing method Exclusive configuration software Drawing tool Name of exclusive configuration software: V-SFT-5 Personal computer: Pentium III 800 MHz or above

(Pentium IV 2.0 GHz or above recommended) OS: Windows98SE/NT4.0/Me/2000/XP/XP64 Edition/Vista 32-bit Capacity of hard disk required:

Free space of approx. 850 Mbytes or more Display: Resolution 1024 x 800 or above Screen color: 16 bits or more

(7) Display function specifications

Interface language (Note1) Japanese English/ Western Europe

Characters 1/4-size, 1-byte ANK code Latin 1 ASCII code ASCII code ASCII code 2-byte 16-dot JIS #1, 2 levels - Chinese (traditional)

Hangul (without Kanji) 2-byte 32-dot JIS #1 level - Font Windows font Stroke font (under development) Character size 1/4-size 8 x 8 dots 1-byte 8 x 16 dots 2-byte 16 x 16 dots or 32 x 32 dots Enlargement factor

X: 1 to 8 times, Y: 1 to 8 times Point (Note: 2) : 8, 9, 10, 11, 12, 14, 16, 18, 20, 22, 24, 26, 28, 36, 48, 72 Number of displayable characters

1/4-size 100 characters x 75 lines 1-byte 100 characters x 37 lines 2-byte 57 characters x 37 lines Character properties Display properties: Normal, reverse, blink, bold, shadow, transparent Colors: 65,536 colors (without blinks) / 32,768 colors (with blinks) Graphics Lines: Line, continuous line, box, parallelogram, polygon Circles: Circle, arc, sector, ellipse, elliptical arc Others: Tile patterns Graphic properties Line types: 6 (thin, thick, dot, chain, broken, two-dot chain) Tile patterns: 16 (incl. user-definable 8 patterns) Display properties: Normal, reverse, blink Colors: 65,536 colors (without blinks) 32,768 colors (with blinks) Color selection: Foreground, background, boundary (line)

Gothic, English/Western Europe HK Gothic, English/Western Europe HK Times, Central Europe, Cyrillic, Greek, Turkish. For more information, refer to the “V8 series Reference Manual.” Note: 2) Applicable when Gothic font, Windows font or stroke font is used.

Show 8 more labels / short text on this page
(6) Drawing environment · Item Specifications · Chinese (Traditional) · Chinese (Simplified) · Korean · Chinese (simplified) · Display resolution · 800 x 600
Page 19 of the Epson FEH300b user manual — 2-1 Specifications
Page 19 · click to enlarge
Page 19

2-1 Specifications

(8) Function performance specifications

Screens Max. 1024 Screen memory Flash memory: Approx. 12.5 Mbytes (Varies depending on the font) Switch 1024 per screen Switch actions Set, reset, momentary, alternate, to light (Possible to press a function switch and a switch on the display at the same time) Lamp Reverse, blink, exchange of graphics 1024 per screen Graph Pie, bar, panel meter and closed area graph:No limitation Statistics and trend graphs: Max. 256 per layer (Note: 2) Data setting

Numerical data display No limitation Character display No limitation Message display Display resolution: 800 x 600: Max. 100 characters (1-byte) No limitation Sampling Sampling display of buffer data (Constant sampling, bit synchronization, alarm logging, time order alarming, alarm

function) Graphic library Max. 2560 Overlap library Max. 1024 Data blocks Max. 1024 Messages Max. 32768 lines Patterns Max. 1024 Macro blocks Max. 1024 Page blocks Max. 1024 Direct blocks Max. 1024 Screen blocks Max. 1024 Data sheets Max. 1024 Screen library Max. 1024 Comments Max. 32768 Device memory map Max. 32 x 8 (PLC1 to PLC8) Time display Provided Hard copy Provided Buzzer Provided, 2 sounds (short beep, long beep) Auto OFF function Always ON, random setting Self-diagnostic function Switch self-test function Communication parameter setting check function Communication check function

Item Specifications

Page 20 of the Epson FEH300b user manual — 2-1-3 Controller unit specifications
Page 20 · click to enlarge
Page 20

2-1 Specifications

2-1-3 Controller unit specifications

(1) Application performance specifications

Control system Stored program, Cyclic scanning system (default task), periodic task, event task

Input / Output connection method Direct input / output (SX bus)

I/O control system Via SX bus: Synchronous refresh with takt

CPU 32-bit RISC processor

Memory types Program memory, data memory, temporary memory

Programming language IL language (Instruction List) LD language ST language (Structured Text) ST language LD language (Ladder Diagram) FBD language (Function Block Diagram) SFC elements (Sequential Function Chart) Program memory capacity 49152 steps Memory I/O memory 512 words (Up to 256 words, useable I/O memory on the @E.Termina for MC.) General memory 65536 words Retain memory 22528 words 8192 words User FB instance memory 4096 words 8192 words Memory for System FB

6144 words 16384 words Timer 256 points 512 points Integrating timer 64 points 128 points Counter 128 points 256 points Edge detection 512 points 1024 points Others 2048 words 8192 words System memory 512 words No. of tasks Default tasks (Cyclic scanning): 1 Periodic tasks: 4 Event tasks : 4 (Total of 4 tasks when periodic task is used) No. of programs Max. 256 (Max. 128 for one task) Diagnosis function Self diagnosis (memory checking, ROM sum checking), system configuration monitoring, module fault monitoring Secret preserving function By password (set with the support tool) Calendar Available up to 12/31/2069 23:59:59 Precision: ± 27 s/month (at 25 °C, when active) Backup of application program Flash ROM built in CPU module Backup area: Application program, system definition, ZIP file User ROM function Application programs, system definitions, zipped files and compressed projects can be stored in user ROM cards. Backup of data memory

Backup area Retain memory, retain attributed memory (e.g. current value of counter), calendar IC memory, RAS area Battery Lithium primary cell, replacement time: 5 minutes or less (at 25 °C) Backup period Approx. 5 years (at 25 °C)

  • CPU module. For more information on memory, language, and system definition, please refer to “User’s Manual Instruction Edition, MICREX-SX series” as appropriate for your programming support tool.
  • SX-Programmer Standard FEH588
  • SX-Programmer Expert (D300win) FEH200

Item Specifications · Type NP5M0101-5H4/4H4/3H4 NP5N0011-5H4/4H4/3H4

Page 21 of the Epson FEH300b user manual — SM1240 (%MX10.124.0)
Page 21 · click to enlarge
Page 21

2-1 Specifications

(2) Specific system memory The table below lists system memory specific to @E.Terminal controller unit.

[Expansion annunciator relay area]

Display unit connection status flag

Represents whether a display unit is connected (ON/OFF of display unit power supply). 1: Connected 0: None

SM1240 (%MX10.124.0)

[Cause of memory error]

Address Names Descriptions Level SM84 (%MX10.8.4)

Display unit DPRAM error Turns ON when an error occurs in DPRAM for display unit I/F in controller unit.

Address Names Descriptions · Fatal fault

Page 22 of the Epson FEH300b user manual — 2-2 Dimensions and Panel Cut-out
Page 22 · click to enlarge
Page 22

2-2 Dimensions and Panel Cut-out

2-2-1 External dimensions and panel cut-out dimensions for the NP5M0101-5H4/NP5N0011-5H4 (Unit: mm)

  • Front view

313.0 +0.5

Epson FEH300b — 2-2 Dimensions and Panel Cut-out diagram (page 22)
Fig. 7 · 2-2 Dimensions and Panel Cut-out

F 7 F 6 F 5 F 4 F 3 F 2 F 1

  • Bottom view

radius of bend in the cable is at least 50mm. Plug/unplug the SX bus expansion cable in the perpendicular direction.

Page 23 of the Epson FEH300b user manual — 2-2 Dimensions and Panel Cut-out
Page 23 · click to enlarge
Page 23

2-2 Dimensions and Panel Cut-out

2-2-2 External dimensions and panel cut-out dimensions for the NP5M0101-4H4/NP5N0011-4H4 (Unit: mm)

  • Front view
Epson FEH300b — 2-2 Dimensions and Panel Cut-out diagram (page 23)
Fig. 8 · 2-2 Dimensions and Panel Cut-out

radius of bend in the cable is at least 50mm. Plug/unplug the SX bus expansion cable in the perpendicular direction.

Page 24 of the Epson FEH300b user manual — 2-2-3 External dimensions and panel cut-out dimensions for the NP5M0101-3H4/NP5N0011-3H4
Page 24 · click to enlarge
Page 24

2-2 Dimensions and Panel Cut-out

2-2-3 External dimensions and panel cut-out dimensions for the NP5M0101-3H4/NP5N0011-3H4

(Unitmm)
  • Front view

220.5 +0.5

Epson FEH300b — 2-2-3 External dimensions and panel cut-out dimensions for the NP5M0101-3H4/NP5N0011-3H4 diagram (page 24)
Fig. 9 · 2-2-3 External dimensions and panel cut-out dimensio…

radius of bend in the cable is at least 50mm. Plug/unplug the SX bus expansion cable in the perpendicular direction.

Page 25 of the Epson FEH300b user manual — (2) NP5M0101-4H4/NP5N0011-4H4
Page 25 · click to enlarge
Page 25

2-3 Names and Functions

2-3-1 Display unit

(1) NP5M0101-5H4/NP5N0011-5H4

Epson FEH300b — 2-3-1 Display unit diagram (page 25)
Fig. 10 · 2-3-1 Display unit
Epson FEH300b — 2-3-1 Display unit diagram (page 25)
Fig. 11 · 2-3-1 Display unit

F 7 F 6 F 5 F 4 F 3 F 2 F 1

(2) NP5M0101-4H4/NP5N0011-4H4

4. 5)
Epson FEH300b — (2) NP5M0101-4H4/NP5N0011-4H4 diagram (page 25)
Fig. 12
Epson FEH300b — (2) NP5M0101-4H4/NP5N0011-4H4 diagram (page 25)
Fig. 13
Show 16 more labels / short text on this page
1) · 4) · 6) · 8) · 5) · 7) · 2) · 3) · 17) · 1) · 6) · 8) · 3) · 7) · 2) · 17)
Page 26 of the Epson FEH300b user manual — (3) NP5M0101-3H4/NP5N0011-3H4
Page 26 · click to enlarge
Page 26

2-3 Names and Functions

(3) NP5M0101-3H4/NP5N0011-3H4

4. 5)
Epson FEH300b — (3) NP5M0101-3H4/NP5N0011-3H4 diagram (page 26)
Fig. 14
Epson FEH300b — (3) NP5M0101-3H4/NP5N0011-3H4 diagram (page 26)
Fig. 15
8. 16)
1. Display This is the display unit.
2. Power lamp (POWER) Illuminates in green when the display unit is powered on, and is operating normally. Flashes when an error occurs to the backlight (burned-out backlight, etc.).
3. Function keys Used for RUN/STOP selection, brightness adjustment and backlight ON/OFF (setting on the V-SFT-5 editor required). These switches can be used as user-defined switches in the RUN mode.
4. Communication interface unit connector (CN5) Connects with the controller unit.

* Hidden by the controller unit.

5. Optional unit connector (CN7) Used for mounting the optional unit “GU-xx” for video input, sound output, RGB input or RGB output.
6. Battery holder Contains a backup battery for SRAM and clock. When the battery voltage drops, replace the battery with a new one (V7-BT).

* Hidden by the controller unit. Replace battery by detaching the controller unit.

7. CF card connector (CF) This is the connector where the CF card is inserted. Access to the CF card is enabled when the cover is closed.
8. Dip switch 8-bit Dip switch used for setting terminating resistance of the CN1 signal line and the MJ1/MJ2 RS-485 signal line. * In NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, the dip switch is hidden by the controller unit. Operate dip switch by detaching the controller unit.
Show 6 more labels / short text on this page
1) · 6) · 7) · 3) · 2) · 17)
Page 27 of the Epson FEH300b user manual — 2-3 Names and Functions
Page 27 · click to enlarge
Page 27

2-3 Names and Functions

9. Power supply terminal block (display unit) Supplies the power to the display unit (24 V DC).
10. Modular jack 1 (MJ1) Used for screen data transfer and connection with PLCs or other peripheral devices.
11. Modular jack 2 (MJ2) Used for connection with PLCs or other peripheral devices.
12. PLC communication connector (CN1) Used for connection with a controller (PLC, temperature controller, inverter, etc.).
13. 100BASE-TX/10BASE-T connector (LAN) Used for Ethernet connection.
14. USB-B (slave port) Used for screen data transfer or connection with a PictBridge-compatible printer.
15. USB-A (master port) This is the connector where a printer or a CF card reader/writer is connected.
16. USB cable clamp mounting hole For NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, this hole is used for attaching a USB cable clamp. For NP5M0101-3H4/NP5N0011-3H4, this hole is used for attaching a USB cable binder.
17. Mounting holes Used for inserting fixtures when securing the @E.Terminal to the mounting panel.
Page 28 of the Epson FEH300b user manual — LOADER
Page 28 · click to enlarge
Page 28

2-3 Names and Functions

2-3-2 Controller unit

Seal of the occasion of next

4. Data backup battery
1. Status indication LED
2. Key switch

SX-BUS

ONL ERR UROM RUN ALM BAT

5. SX bus connector

IN

3. CPU No. selection key switch

4:RUN 3:U-TERM 2:TERM 1:STOP

No. CPU

6. Power supply terminal block (3 poles)

OUT

24V DC +

9. USB-miniB connector

FG

USER ROM CARD

USB

Version No.

LOADER

8. Loader connector 7) Connector for user ROM card (CF card)

Name plate · battery replacement

Page 29 of the Epson FEH300b user manual — RUN ALM
Page 29 · click to enlarge
Page 29

2-3 Names and Functions

1. Status indication LED (Controller unit)

ONL ERR

Status of the controller unit.

ONL ERR Status of controller unit

OFF OFF Power OFF, system resetting or initializing

Blinks - SX bus standing on

ON OFF Normally running

ON ON Nonfatal fault, at a running

OFF ON Fatal fault at a stop

UROM Green Lights on continuously when the CPU recognizes a user ROM card. Lights on continuously when a user ROM card (compact flash card) is correctly installed in the CPU module and the key switch is set to "3" or "4".

RUN ALM

Status of system of the conntroller unit.

RUN ALM Status of system

OFF OFF Power OFF or application program at a stop

ON OFF Normally running

ON ON Nonfatal fault, at a running

OFF ON Fatal fault, at a stop

Blinks - While the CPU is accessing the user ROM

BAT Orange Turned on when data backup battery dropped or disconnected.

2. Key switch (Controller unit) Selects the running mode of the controller unit.
1. STOP 2: TERM 3: U-TERM 4: RUN * The shipment default is 3 (U-TERM).
3. CPU No. selection key switch Sets the CPU number of the controller unit. Set the number to “0”.
4. Data backup battery (Controller unit) The battery backs up the retain memory of the contoller uint.
5. SX bus connector (IN, OUT) Be sure to connect cable from OUT to IN. For the connection cable, use a dedicated SX bus extension cable.
6. Power supply terminal block (Controller unit) Supplies the power to the display unit (24 V DC).
7. Connector for user ROM card (CF card) (Controller unit) This is the connector where the User ROM card (CF card) is inserted.
8. Loader connector For the personal computer loader, use a RS-232C port.
9. USB-miniB connector (Controller unit) Connects to the USB port of a personal computer loader. Please use a commercially sold USB cable (male A connector _ male miniB connector).
Show 6 more labels / short text on this page
Symbol Color Descriptions · Green Red · <Lights on pattern> · Green Red · (Note) · <Lights on pattern>
Page 30 of the Epson FEH300b user manual — 2-4 Serial Connector
Page 30 · click to enlarge
Page 30

2-4 Serial Connector

Communication (RS-232C, RS-422/485) with a controller is enabled via the serial connector (CN1).

  • For NP5M0101-5H4/4H4 NP5N0011-5H4/4H4
  • For NP5M0101-3H4 NP5N0011-3H4

Bottom view Bottom view

Epson FEH300b — 2-4 Serial Connector diagram (page 30)
Fig. 16 · 2-4 Serial Connector

The serial connector pins correspond to signals as given below.

Epson FEH300b — 2-4 Serial Connector diagram (page 30)
Fig. 17 · 2-4 Serial Connector

6 NC Not used +RTS Request to send (+)

7 RTS Request to send -RTS Request to send (-)

9 NC Not used +5V Use prohibited (Note: 2)

When RS-232C is selected, set the dip switches 5 and 7 to the OFF position. (For more information on the dip switch, refer to “Chapter 2-6”.) Note: 2) When RS-422/485 is selected, +5V is output from pin No. 9.

+5V is used as the power supply for the external terminating resistance for RS-422/485 communication. It cannot be used as an external power supply.

Recommended connector The following connector is recommended for a self-made cable.

DDK's 17JE-23090-02 (D8C) -CG D-sub 9-pin / male / inch screw thread (#4-40UNC) type / with hood / lead- and cadmium-free

Recommended connector

Page 31 of the Epson FEH300b user manual — 2-5 Modular Jack (MJ1 / MJ2)
Page 31 · click to enlarge
Page 31

2-5 Modular Jack (MJ1 / MJ2)

A screen data transfer cable (MJ1 only), temperature controller, barcode reader, CREC, or V-I/O can be connected to the modular jack (MJ1 or MJ2).

  • For NP5M0101-5H4/4H4 NP5N0011-5H4/4H4
  • For NP5M0101-3H4 NP5N0011-3H4

Bottom view Bottom view

Epson FEH300b — 2-5 Modular Jack (MJ1 / MJ2) diagram (page 31)
Fig. 18 · 2-5 Modular Jack (MJ1 / MJ2)

Pins of MJ1 and MJ2 correspond to signals as given below.

Epson FEH300b — 2-5 Modular Jack (MJ1 / MJ2) diagram (page 31)
Fig. 19 · 2-5 Modular Jack (MJ1 / MJ2)
  • For MJ1 and MJ2, the maximum allowable current is 150 mA in total.
  • When connecting an optional unit or communication unit, be careful not to exceed the total allowable current (650 mA) for USB-A, MJ1 and MJ2.
Page 32 of the Epson FEH300b user manual — ON
Page 32 · click to enlarge
Page 32

2-6 Dip Switches

In NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, the dip switch is hidden by the controller unit. Operate the dip switch by detaching the controller unit. The @E.Terminal is equipped with eight (1 to 8) dip switches. When setting the dip switch, turn the power off. Upon delivery, all the dip switches are set to OFF.

  • For NP5M0101-5H4/4H4 NP5N0011-5H4/4H4
  • For NP5M0101-3H4 NP5N0011-3H4

Rear view Rear view

Epson FEH300b — 2-6 Dip Switches diagram (page 32)
Fig. 20 · 2-6 Dip Switches

ON

1 2 3 4 5 6 7 8

MJ2 (modular jack 2) terminating resistor

CF auto-uploading Not used

CN1 +RD/-RD terminating resistor at pins 1 and 2 MJ1 (modular jack 1) terminating resistor

CF card interface cover access control

CN1 +SD/-SD terminating resistor at pins 3 and 4

Dip switch number 1 (Note) (CF Auto-uploading)

Set the dip switch number 1 to the ON position when auto-uploading a screen data file saved on a CF card.

1. Have a CF card Have a CF card to which the screen data is loaded using the V-SFT-5 editor. (For the loading procedure, refer to the “V8 series Reference Manual.” )
2. Insert a CF card Turn the power of the display unit off, and set the dip switch number 1 to the ON position. Open the CF card interface cover, and insert a CF card.
3. Auto-uploading starts Turn the power of the display unit on. The screen data is automatically loaded into the FLASH memory of the unit.

Dip switch · Procedure

Page 33 of the Epson FEH300b user manual — 2-6 Dip Switches
Page 33 · click to enlarge
Page 33

2-6 Dip Switches

Dip switch number 2 (CF Card interface cover access control)

When the dip switch number 2 is set to the ON position, access to the CF card is possible whether the cover is opened or not. In case access to the CF card is disabled because of damage of the CF card interface cover, set the dip switch number 2 to the ON position. Normally keep it in the OFF position. Caution

With the dip switch number 2, the LED status when the CF card interface cover is opened can be set.

Epson FEH300b — 2-6 Dip Switches diagram (page 33)
Fig. 21 · 2-6 Dip Switches

Not lit Access to the CF card is not performed. CF card can be removed.

Lights up in red Accessing the CF card. After the access is finished, the LED goes off.

ON Lights up in red Access to the CF card is possible at all times.

Dip switch number 3, 4 (Not used)

Set the dip switch number 3 and 4 to OFF.

Dip switch number 5, 6, 7, 8 (Terminating resistor setting)

  • When connecting a controller at CN1 via RS-422/485 (2-wire connection), set the dip switch number 7 to the ON position.
  • When connecting a controller at CN1 via RS-422/485 (4-wire connection), set the dip switch number 5 and 7 to the ON position.
  • For the following connections at modular jack 1 or 2, set the dip switch number 6 or 8 to the ON position.
  • Master station for multi-link 2 connection
  • Connection with a controller (PLC, temperature controller, etc.) via RS-485
  • Connection with the card recorder “CREC” (optional)
  • Connection with the serial extension I/O “V-I/O” (optional)
  • Connection to the @E.Terminal at the termination of V-Link connection via RS-485

* Detaching controller unit To operate the dip switch in NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, remove the controller unit. Remove mounting screws at three places to remove the controller unit from the display unit. Be careful not to drop or lose the mounting screws.

Epson FEH300b — 2-6 Dip Switches diagram (page 33)
Fig. 22 · 2-6 Dip Switches

Mounting screws at three places M3 screws thread, Tightening torque:

0.5 to 0.7N·m

Page 34 of the Epson FEH300b user manual — 3-2 Power Supply Cable Wiring ........................................................................................ 3-2
Page 34 · click to enlarge
Page 34

Section 3 Installation

3-1 Mounting Procedure 3-1

(1) Mounting procedure 3-1 (2) Mounting angle 3-1

3-2 Power Supply Cable Wiring 3-2

(1) Power supply cable wiring 3-2 (2) Grounding 3-4

Page

Page 35 of the Epson FEH300b user manual — Section 3 Installation
Page 35 · click to enlarge
Page 35

Section 3 Installation

3-1 Mounting Procedure

1. Insert the @E.Terminal unit into the mounting panel (max. thick: 5 mm).
Epson FEH300b — Section 3 Installation diagram (page 35)
Fig. 23 · Section 3 Installation
Epson FEH300b — Section 3 Installation diagram (page 35)
Fig. 24 · Section 3 Installation
2. Insert four fixtures attached to the @E.Terminal unit into the mounting holes, and tighten them with the tightening screws. Tightening torque: 0.5 to 0.7 N·m
Epson FEH300b — Section 3 Installation diagram (page 35)
Fig. 25 · Section 3 Installation
Fixture dimensions (Unitmm)

* When the @E.Terminal unit is attached to the mounting panel, the fixtures and frame grounds (FG) are connected. To prevent static electricity, be sure to connect the mounting panel to the frame ground.

3. Mount the gasket so that it will be sandwiched securely between the @E.Terminal unit and the mounting panel.

(2) Mounting angle Install the unit within the angle of 15° to 135° as shown on the right.

Show 7 more labels / short text on this page
(1) Mounting procedure · 90° · 135° · 15° · Display · Display · 0°
Page 36 of the Epson FEH300b user manual — 24V DC +
Page 36 · click to enlarge
Page 36

3-2 Power Supply Cable Wiring

(1) Power supply cable wiring Power supply terminal blocks of the display unit and the controller unit are connected with each other with a cable by default. Use one power supply terminal block to connect the power supply cable.

  • For NP5M0101-5H4/4H4 NP5N0011-5H4/4H4
  • For NP5M0101-3H4 NP5N0011-3H4

Connect the power supply cable to the power supply terminal block of the controller unit. Connect the power supply cable to the power supply terminal block of the display unit.

Epson FEH300b — 3-2 Power Supply Cable Wiring diagram (page 36)
Fig. 26 · 3-2 Power Supply Cable Wiring
  • Attaching noise filter Attach accompanying noise filter to the power supply cable between the DC power supply and the power supply terminal block.

Keep the distance between the DC power supply and the power supply module as short as possible, and the cable must be twisted densely.

Epson FEH300b — 3-2 Power Supply Cable Wiring diagram (page 36)
Fig. 27 · 3-2 Power Supply Cable Wiring

24V DC +

FG

Do not bundle up and do not close.

* Noise filter is not required for controller unit hardware version “03” or later. Noise filter is not attached as accessory with above version.

DC power supply

Page 37 of the Epson FEH300b user manual — NTK
Page 37 · click to enlarge
Page 37

3-2 Power Supply Cable Wiring

  • Tighten terminal screws on the power supply terminal block of the display unit with the following torque. Use a power supply cable within the range shown below.

NP5M0101-5H4 NP5M0101-4H4 NP5N0011-5H4 NP5N0011-4H4

3.7mm

φ 3.7mm

M3.5 0.8N·m AWG18 - 16

3.7mm

φ 3.7mm

NP5M0101-3H4 NP5N0011-3H4 M3.5 1.2N·m AWG16 - 14

7.1mm or less

7.1mm or less

  • The power supply terminal block of the controller unit uses M3 terminal screws. Their tightening torque should be 0.5 to 0.6 N·m. Select the appropriate cable, and crimp terminals to be used. Applicable cable sizes and crimp terminals are as follows:

Maker Form Types Cable size AWG mm2

36467 22 to 18 0.3 to 0.8 mm2 34104 34105

0.3-3 24 to 20 0.2 to 0.5 mm2 0.3-3N 1.25-3

22 to 16 0.3 to 1.3 mm2 1.25-3N 1.25-3S 1.25-3.5N 1.25-3.5S 2-3N 16 to 14 1.3 to 2.0 mm2

0.3Y-3 24 to 20 0.2 to 0.5 mm2

1.25Y-3

22 to 16 0.3 to 1.3 mm2 1.25Y-3N 1.25Y-3S 1.25Y-3.5 2Y-3 16 to 14 1.3 to 2.0 mm2 2Y-3.5S AT1-10 22 to 16 0.3 to 1.3 mm2

AT2-10 16 to 14 1.3 to 2.0 mm2

SRA-20-3.2 22 to 18 0.3 to 0.8 mm2 SRA-20T-3.2

0.4-3 26 to 22 0.2 to 0.3 mm2

1.25-3 22 to 16 0.3 to 1.3 mm2 Angle edge terminals

NTK

VR1.25-3 VD1.25-3 VD2-3S 16 to 14 1.3 to 2.0 mm2

Show 16 more labels / short text on this page
Tterminal screw · Power · Types · Cable Screw · Tightening · torque Crimp-style terminal · size · 8mm or less · 8mm or less · AMP Round terminals · Round terminals · Terminal dimensions · Nichifu · Angle edge terminals · JST Round terminals · Round terminals
Page 38 of the Epson FEH300b user manual — 3-2 Power Supply Cable Wiring
Page 38 · click to enlarge
Page 38

3-2 Power Supply Cable Wiring

  • An independent earth pole must be used for the @E.Terminal.
  • Use a cable which has a nominal cross section of more than 2 mm 2 for grounding.
  • Set the grounding point near the @E.Terminal to shorten the distance of grounding cables.

Other equipment @E.Terminal Other equipment @E.Terminal Other equipment @E.Terminal

* When the @E.Terminal unit is attached to the mounting panel, the fixtures and frame grounds (FG) are connected. To detach the FG terminal from the ground, attach the insulating sheet to the fixtures and the mounting panel for insulation.

(2) Grounding

Page 39 of the Epson FEH300b user manual — 4-3 Maintenance Services ................................................................................................ 4-4
Page 39 · click to enlarge
Page 39

Section 4 Inspection and Maintenance

4-1 Inspection and Maintenance 4-1

4-1-1 Daily inspection 4-1

4-1-2 Periodical inspection 4-1

4-2 Battery Replacement 4-2

(1) Battery specification 4-2 (2) Precautions 4-2 (3) How to replacement battery 4-2

4-3 Maintenance Services 4-4

4-3-1 Ordering notes 4-4

4-3-2 Free-of-charge warranty period and scope of warranty 4-4

4-3-3 Service costs 4-4

Page

Page 40 of the Epson FEH300b user manual — Section 4 Inspection and Maintenance
Page 40 · click to enlarge
Page 40

Section 4 Inspection and Maintenance

4-1 Inspection and Maintenance

  • 4-1-1 Daily inspection
  • Check that the screws on the @E.Terminal are tightened firmly.
  • Check that the connectors and terminal screws used for connection with other devices are tightened firmly.
  • If the display surface or frame is dirty, wipe it with a soft cloth soaked in alcohol (commercially available).
  • Conduct periodical inspection once or twice a year. The number of inspections may be increased as necessary if facilities are relocated or modified, or the environment is hot, humid, or dusty.

4-1-2 Periodical inspection Inspect the following points periodically.

  • Are the ambient temperature and humidity appropriate? 0 to +50 ° C, 85 % RH or less
  • Are the environmental conditions appropriate? No excessive dust, no conductive dust contamination, and not stained with organic solvents.
  • Does the atmosphere contain no corrosive gas?
  • Is the source voltage in the allowable range? With DC power supply: 24 V DC ± 10 %
  • Are the @E.Terminal mounting screws tightened firmly?
  • Are the connectors and terminal screws used for connection with other devices tightened firmly?
  • Is the lithium primary battery within the expiry date? About 5 years from the date of your purchase
Page 41 of the Epson FEH300b user manual — Battery replacement
Page 41 · click to enlarge
Page 41

4-2 Battery Replacement

Battery replacement

When the time comes to replacement the battery, replace it for a new one even if battery error is not displayed. Also, when low battery voltage of the display unit and the controller unit is discovered, replace the battery for a new one immediately. Replacement the batteries of the display unit and the controller unit at the same time.

  • Controller unit

Battery specification Lithium primary cell

Backup time Approx. 5 years (Ambient temperature at 25 °C)

Battery boltage drop detection funnction

Provided (Status indication LEDBAT)
Battery for replacement TypeNP8P-BT

Required time in the battery replacement

5 minutes or less

  • Display unit

Battery specification Coin-type lithium primary cell

Backup time Approx. 5 years (Ambient temperature at 25 °C)

Battery boltage drop detection funnction

Provided (Internal memory of $s167 allocated)

Battery for replacement TypeV7-BT

Required time in the battery replacement

3 minutes or less

  • (2) Precautions
  • Do not short across the battery.
  • Do not discard in a fire.
  • Do not attempt to recharge the battery.
  • Do not disassemble the battery.
  • Observe local and governmental regulations when disposing of waste batteries.

(3) How to replacement battery

  • Battery replacement of controller unit 1) Turn off power supply of the @E.Terminal. 2) Remove battery holder cover at top of controller unit. Remove battery connector and then remove battery from battery holder. 3) Attach a new battery connector, mount battery into the battery holder, and attach the cover. Perform the exchange quickly (within five minutes). When battery is detached for a long time, the data retained during power outage may become erased. 4) Enter the battery guarantee period on a seal to be used on the occasion of the next battery replacement, and affix seal to the controller unit.

(1) Battery specification · Items Specifications · Items Specifications

Page 42 of the Epson FEH300b user manual — 4-2 Battery Replacement Battery replacement
Page 42 · click to enlarge
Page 42

4-2 Battery Replacement Battery replacement

  • Battery replacement of display unit 1) Remove the controller unit from @E.Terminal. Remove mounting screws at three places to remove the controller unit from the display unit. Be careful not to drop or lose the mounting screws.
Epson FEH300b — 4-2 Battery Replacement Battery replacement diagram (page 42)
Fig. 28 · 4-2 Battery Replacement Battery replacement

Mounting screws at three places M3 screws thread, Tightening torque:

0.5 to 0.7N·m

2. Open the battery holder cover of the display unit in the direction of the arrow as shown in the left illustration below.
Epson FEH300b — 4-2 Battery Replacement Battery replacement diagram (page 42)
Fig. 29 · 4-2 Battery Replacement Battery replacement
Epson FEH300b — 4-2 Battery Replacement Battery replacement diagram (page 42)
Fig. 30 · 4-2 Battery Replacement Battery replacement
3. Remove battery connector, and slide battery to remove it from its socket, as shown in the right figure.
4. Insert a new battery into the socket so that the red cable side of the new battery faces the board and the cable is on the left side. Next, slide battery from the arrow key direction shown in the right figure.
5. Connect the battery connector, and close the battery holder cover.
6. Attach the controller unit to the display unit and fix it with mounting screws at three places.

the unit is turned off. If it is not possible to replace within three minutes, make a backup copy of data in the SRAM.

Show 4 more labels / short text on this page
Battery holder · Socket · Printed circuit board · Battery connector
Page 43 of the Epson FEH300b user manual — 4-3-2 Free-of-charge warranty period and scope of warranty
Page 43 · click to enlarge
Page 43

4-3 Maintenance Services Maintenance services

4-3-1 Ordering notes When ordering electrical and control equipment (or requesting price estimates), the following general notes are to be observed, unless otherwise specified in the estimation paper, contract paper, catalogs, or specifications. When the product is delivered, check the contents of the package as soon as possible. Even before inspection, use caution on storing and using the product safely.

4-3-2 Free-of-charge warranty period and scope of warranty

[Free-of-charge warranty period] (1) This product is covered by a warranty for a period of one year from the date of purchase or 18 months from the date of

manufacture described in the nameplate, whichever comes earlier. (2) This warranty period may not be applied if the operating environment, operating condition, operating frequency, or

number of operations affects the operating life of the product. (3) The warranty period for the product section repaired by Fuji Electric service sector is six (6) months from the date of

completion of repair.

[Warranty period] (1) If a failure judged to be the responsibility of Fuji Electric occurs during the warranty period, the failed section of the

product is replaced or repaired on a free-of-charge basis at the site of purchase or delivery of the product. However, the following failures are not covered by this warranty.

  • Breakage of or damage to the appearance (case or surface sheet), touch switches, LCD, or other components due to dropping, impact, or mishandling
  • LCD or backlight at the end of life
  • Fusion of a printed circuit board pattern associated with connection to external devices, or fusion of a pattern in the terminal block or connector section of a printed circuit board caused by short-circuiting of external load circuit
  • Overvoltage or different voltage applied due to wiring mistake (power supply terminal, external communication terminal, or other terminal blocks)
  • Failure caused by lightning surge
  • Failure due to the entry of conductive substances, water, solvent, particles, etc. under inappropriate environmental conditions
  • Failure due to inappropriate environmental conditions (e.g. corrosive gas or high humidity)
  • Failure due to vibration or impact exceeding the specified level
  • Disassembly and modification by the customer or failure obviously resulting from improper handling by the customer (2) The warranty is limited only to a single purchased product and a single delivered product. (3) The upper limit of the warranty period is (1). Any damages caused by failures of the purchased product and delivered

product (damages to or loss of machinery and equipment, or passive damages) are not covered by this warranty.

[Repair period after production stoppage and supply period of spare parts (maintenance period)] As for retired models (products), Fuji Electric performs repair work within seven (7) years from the date of retirement. As for major spare parts for repair, Fuji Electric also performs repair work within seven (7) years from the date of retirement. With electronic parts, however, difficulty in procurement or production may be anticipated because of short life cycles and therefore repair or spare parts supply may be difficult even during the warranty period. For details, please contact Fuji Electric sales office or service sector.

4-3-3 Service costs The price of the product does not include maintenance and servicing costs, such as the cost of dispatching an engineer to the customer. The customer will be charged for actual expenses in the following cases. (1) Guidance for installation and adjustment, and attendance at a test operation (2) Maintenance, inspection, adjustment, and repair (3) Technical guidance and technical education

Page 44 of the Epson FEH300b user manual — Appendix 1 About Project for @E.Terminal (No contents installed) .................... App. 1-1
Page 44 · click to enlarge
Page 44

Appendix 1 About Project for @E.Terminal

(No contents installed)

Appendix 1 About Project for @E.Terminal (No contents installed) App. 1-1

Page

Page 45 of the Epson FEH300b user manual — App. 1-1
Page 45 · click to enlarge
Page 45

Appendix 1 About Project for @E.Terminal

(No contents installed)

When you make new project for controller of @E.Terminal (No contents installed) by personal computer loader (SX- programmer Expert/ Standard), download template for new project from our homepage. The project for controller of @E. Terminal for MC is stored in backup CD.

(1) Download template Access to our homepage, download from [Software libraries] of [Programmable controllers]. (Address: http://www.fesys.co.jp/eng/)

  • (2) Template file
  • The file for SX-programmer Expert (SPH2000-48CR.zwt) The file is compressed project type. Uncompress the project before use.
  • The file for SX-programmer Standard (SPH2000-48CR.Sxt) The file is template type. Register template in the loader before use.

(3) Order to register template to SX-Programmer Standard. When you click [File]-[New], [Template selection] screen is displayed. Right click mouse under description area, and select [import]. Select template file at [import] dialog, and click open.

Epson FEH300b — Appendix 1 About Project for @E.Terminal diagram (page 45)
Fig. 31 · Appendix 1 About Project for @E.Terminal
Epson FEH300b — Appendix 1 About Project for @E.Terminal diagram (page 45)
Fig. 32 · Appendix 1 About Project for @E.Terminal
Epson FEH300b — Appendix 1 About Project for @E.Terminal diagram (page 45)
Fig. 33 · Appendix 1 About Project for @E.Terminal

Template of is registered at [Template selection] screen.

(4) Notes In [Execution band ratio setting] of [CPU running definition], proportion of [Built-in] must be set as “0.”

Epson FEH300b — Appendix 1 About Project for @E.Terminal diagram (page 45)
Fig. 34 · Appendix 1 About Project for @E.Terminal

App. 1-1

Page 46 of the Epson FEH300b user manual — Back Cover
Page 46 · click to enlarge
Page 46

Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032,Japan Phone: +81-3-5435-7280 Fax: +81-3-5435-7425 URL http://www.fesys.co.jp/eng/

Printed on recycled paper.

Printed in Japan 2008-12 FIS

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Epson FEH300b

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Epson FEH300b

Be the first to ask — other owners or our team will answer.

Original document

Epson FEH300b manual PDF

46 pages·1 MB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…