@E.Terminal for MC
USER'S MANUAL
Hardware

This hardware edition of the user’s manual describes system composition, specifications, and handling of the @E.Terminal. In order to operate the hardware properly, please read this user’s manual carefully. When using modules or peripheral devices, be sure to read the corresponding user’s manuals listed below.
In addition to the above manuals, the following Fuji Electric Systems Co., Ltd. site offers various manuals and technical documents associated with the @E.Terminal for MC.
Notes

Be sure to read the “Safety Precautions” thoroughly before using the module. Here, the safety precaution items are classified into “Warning” and “Caution.”
Even some items indicated by “Caution” may also result in a serious accident.
Both safety instruction categories provide important information. Be sure to strictly observe these instructions.
◊Never use the output signal of @E.Terminal for operations that may threaten human life or damage the system, such
as signals used in case of emergency. Please design the system so that it can cope with the malfunctions of a touch switch. A malfunction of a touch switch will result in machine accident or damage. ◊Turn off the power supply when you set up the unit, connect new cables or perform maintenance or inspections.
Otherwise, electrical shock or damage may occur. ◊Never touch any terminals while the power is on. Otherwise, electric shock may occur. ◊You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Otherwise,
electric shock may occur. ◊The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, do not ingest the leaked
liquid crystal. If the liquid crystal spills on skin or clothing, use soap and wash off thoroughly. ◊Never disassemble, recharge, deform by pressure, short-circuit, reverse the polarity of the lithium battery, nor dispose
of the lithium battery in fire. Failure to follow these conditions will lead to explosion or ignition. ◊Never use a lithium battery that is deformed, leaks, or shows any other signs of abnormality. Failure to follow these
conditions will lead to explosion or ignition. ◊The power lamp flashes when the backlight is at the end of life or is faulty. However, the switches on the screen are
operable at this time. Do not touch the screen when the screen becomes dark and the power lamp flashes. Otherwise, a malfunction may occur and result in machine accident or damage.

◊Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found.
Failure to do so may lead to fire, damage or malfunction. ◊For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile
installations, please consult your local distributor. ◊Operate (or store) @E.Terminal under the conditions indicated in this manual and related manuals. Failure to do so
could cause fire, malfunction, physical damage or deterioration. ◊Understand the following environmental limits for use and storage of @E.Terminal. Otherwise, fire or damage to the
unit may result. - Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding fluids or cutting oil can come into contact with the unit. - Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight. - Avoid locations where excessive dust, salt, and metallic particles are present. - Avoid installing the unit in a location where vibration or physical shock may be transmitted. ◊Equipment must be correctly mounted so that the main terminal of @E.Terminal will not be touched inadvertently.
Otherwise, an accident or electric shock may occur. ◊Check periodically that terminal screws on the power supply terminal block and fixtures are firmly tightened. Loosened
screws may result in fire or malfunction. ◊Tighten terminal screws on the power supply terminal block of display part equally to a torque of 0.8 N·m for the
NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, or 1.2 N·m for the NP5M0101-3H4/NP5N-0011-3H4. And tighten terminal screws on the power supply terminal block of the controller unit equally to a torque of 0.5 to 0.6 N·m. Improper tightening of screws may result in fire, malfunction, or trouble. ◊Tighten mounting screws on the unit equally to a torque of 0.5 to 0.7 N·m. Excessive tightening may distort the panel
surface. Loose tightening may cause @E.Terminal to come off, malfunction or be short-circuited. ◊@E.Terminal has a glass screen. Do not drop or give physical shock to the unit. Otherwise, the screen may be
damaged. ◊Connect the cables correctly to the terminals of @E.Terminal in accordance with the specified voltage and wattage.
Over-voltage, over-wattage, or incorrect cable connection could cause fire, malfunction or damage to the unit. ◊Be sure to establish a ground of @E.Terminal. The FG terminal must be used exclusively for the unit with the level of
grounding resistance less than 100Ω. Otherwise, electric shock or a fire may occur. ◊Prevent any conductive particles from entering into @E.Terminal. Failure to do so may lead to fire, damage, or
malfunction. ◊After wiring is finished, remove the paper used as a dust cover before starting to operate @E.Terminal. Operation with
the cover attached may result in accident, fire, malfunction, or trouble. ◊Do not attempt to repair @E.Terminal at your site. Ask us or the designated contractor for repair. ◊Do not repair, disassemble or modify @E.Terminal. We are not responsible for any damages resulting from repair,
disassembly or modification of @E.Terminal that was performed by an unauthorized person. ◊Do not use a sharp-pointed tool when pressing a touch switch. Doing so may damage the screen. Doing so may
damage the screen. ◊Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspection. ◊Lithium batteries contain combustible material such as lithium or organic solvent. Mishandling may cause heat,
explosion or ignition resulting in fire or injury. Read related manuals carefully and handle the lithium battery correctly as instructed. ◊When using @E.Terminal that has analog switch resolution with resistance film, do not press two or more points on the
screen at the same time. If two or more positions are pressed at the same time, the switch located between the pressed positions activates. ◊Take safety precautions during such operations as setting change during running, forced output, start, and stop.
Any misoperation may cause unexpected machine motions, resulting in machine accident or damage. ◊In facilities where a failure of @E.Terminal could lead to accident threatening human life or other serious damage, be
sure that the facilities are equipped with adequate safeguards. ◊At the time of disposal, @E.Terminal must be treated as industrial waste. ◊Before touching @E.Terminal, discharge static electricity from your body by touching grounded metal. Excessive static
electricity may cause malfunction or trouble. ◊The LED lamp on the CF card interface cover illuminates in red when the power is supplied to the CF card.
Never remove the CF card or turn off the power of @E.Terminal while the LED lamp is lit. Doing so may destroy the data on the CF card. Check that the LED lamp has gone off before removing the CF card or turning off the power of @E.Terminal.
![Page 5 of the Epson FEH300b user manual — [Notes on LCD]](/cdn/reader/77/779fab2a95a7216d1c7cf49463f3bbec126512d4374c915d84cf7002c3b4e24c/images/page-5.webp?w=400)

*Manual No. is shown on the cover.


1-2 Appearance ................................................................................................................. 1-2
1-3 Types ............................................................................................................................ 1-3
1-4 System Composition .................................................................................................. 1-5
Page

The @E.Terminal for MC Display Attached Controller is an all-in-one programmable operation display and motion controller.
Features:
1) The guidance function of the display screen allows you to easily set up parameters and positioning data previously set up by a dedicated machine. Also, it enables easy equipment maintenance. 2) The SX bus allows one-touch connection of up to eight servo amplifiers (axes) (FALDIC-α and APLHA5 VS type), minimizing the need for wires. 3) The upper level controller can be connected by Ethernet and the like. 4) The lineup includes three different display screen sizes. 8 inch, 10 inch and 12 inch models are available. 5) The content corresponding to motion is supplied in the standard package. Content for PTP control and synchronous control (ratio synchronization, cycle synchronization, flying shear, and rotary shear) are provided.
Ethernet, ctc.

@E.Terminal for MC
Motion functions (Setting/Display) · SX bus Note)

@E.Terminal for MC is composed of a programmable operation display (the display unit) and a controller unit attached to the back of the display unit. The controller unit is attached with screws to the connector area of the communication unit at the back of the display unit, similar to the way in which the communication unit is attached.




Back


* For information about peripheral accessories of the display unit not documented in this manual, please refer to “V8 series Hardware Specifications (2016NEx)”.

The following illustration shows the system composition of @E.Terminal for MC.
USB-B
Up to 8 servos and I/O terminals each can be connected.

"V-CP"
Screen editor "V-SFT-5" (V5.3.0.0 or later)
External PG (only No. 1 axis)
@E.Terminal for MC
FALDIC ALPHA5 FALDIC - α
[No. 1 axis] SX bus station No.: "201"
or commercially available USB cable
[No. 2 axis] SX bus station No.: "202"
FALDIC ALPHA5 FALDIC - α
Programming support tool SX-Programmer Standard "NP4H-SWN" (V2.3.5.1 or later) SX-Programmer Expert (D300win) "NP4H-SEDBV3" (V3.4.4.0 or later)
[No. 8 axis] SX bus station No.: "208"
FALDIC ALPHA5 FALDIC - α
Starting up signal etc.
I/O terminal Input 8 points/ Output 8 points (NR1SW-16T65DT)
SX bus station No.: "221"
RDY etc.
FALDIC-α (RYS***S3-VSS, RYS***M3-VSK) FALDIC ALPHA5 (RYT*** 5-VS )
I/O terminal Input 8 points/ Output 8 points (NR1SW-16T65DT)
SX bus station No.: "228"
PLC/general purpose computer · Ethernet/RS-232C or RS-485 · SX bus

2-1-1 General specifications 2-1
2-1-2 Display unit specifications 2-2
(1) Display unit specifications 2-2 (2) Touch switch specifications 2-2 (3) Function switch specifications 2-2 (4) Interface specifications 2-3 (5) Clock and backup memory specifications 2-3 (6) Drawing environment 2-4 (7) Display function specifications 2-4 (8) Function performance specifications 2-5
2-1-3 Controller unit specifications 2-6
(1) Application performance specifications 2-6 (2) Specific system memory 2-7
2-2-1 External dimensions and panel cut-out dimensions for the
2-2-2 External dimensions and panel cut-out dimensions for the
2-2-3 External dimensions and panel cut-out dimensions for the
2-3 Names and Functions............................................................................................... 2-11
2-3-1 Display unit 2-11
(1) NP5M0101-5H4/NP5N0011-5H4 2-11 (2) NP5M0101-4H4/NP5N0011-4H4 2-11 (3) NP5M0101-3H4/NP5N0011-3H4 2-12
2-3-2 Controller unit 2-14
2-5 Modular Jack (MJ1 / MJ2)......................................................................................... 2-17
2-6 Dip Switches.............................................................................................................. 2-18
Page

2-1 Specifications
Items Specifications NP5M0101-5H4 NP5N0011-5H4
NP5M0101-3H4 NP5N0011-3H4 Physical environmental conditions
0 to +50 °C
-10 to +60 °C
85 % RH or less (Without dew condensation, max. wet-bulb temperature: 39 °C or less) Operational altitude 2000 m or less above sea level (Transport condition: 70 kPa or more) Operational atmosphere No corrosive gas, no excessive dust, no conductive dust contamination, and not stained with organic solvents. Pollution degree 2 (Note1) Mechanical working conditions
Vibration resistance Half-amplitude: 0.075 mm, acceleration: 9.8 m/s2, X, Y, Z: 3 directions for one hour Shock resistance Peak acceleration: 147 m/s2, X, Y, Z: 3 directions three times each Electrical working conditions
Noise resistance Rising time: 1 ns, pulse width: 1 µs, Noise voltage: 1.5 kVp-p (Measured by using a noise simulator.) Static electricity discharge resistance
Power supply Rated input voltage 24V DC (Note2) Rated voltage (tolerance) 24V DC ±10% Permissible momentary power failure
1 ms or less
power supply consumption (Max. rated)
42 W or less 37 W or less 35 W or less
Rush current 170 A or less Input terminal block
controller unit) Tightening torque: 0.8 N·m Controller unit Terminal block screw: M3 Tightening torque: 0.5 to 0.6 N·m Dielectric strength 500 V AC 1 minute (Between external terminals and frame ground) Isolation resistance 500 V DC, 5 MΩor more Dimensions W x H x D (mm) 326.4 x 259.6 x 99.0 303.8 x 231.0 x 99.0 233.0 x 178.0 x 96.0 Mass Approx. 3.5 kg Approx. 3.1 kg Approx. 2.1 kg
conductivity occurs due to condensation. Note 2) Use 24V DC power supply which comply to UL standard Class2 insulation.
Item Specifications Grounding Less than 100Ω, FG/SG separated Protection structure Front panel (Note 1) Compliant with IP65 (When using waterproof gasket) (Note 2) Cooling system Cooling naturally Structure Inserted in a mounting panel Appropriate mounting panel thickness 1.5 to 5 mm
unit compliant with IP65. The strength differs depending on the material of the mounting panel. Check the environment where the @E.Terminal is used.
Operational ambient temperature · Storage ambient temperature · Operational ambient humidity

(1) Display unit specifications
NP5M0101-3H4 NP5N0011-3H4 Display device TFT color Display size 12.1-inch 10.4-inch 8.4-inch Colors 65,536 colors (without blinks) / 32,768 colors (with blinks) Display resolution (W x H) 800 x 600 dots Dot pitch (W x H) 0.3075 x 0.3075 mm 0.264 x 0.264 mm 0.2135 x 0.213 mm Backlight Cold cathode tube Backlight life (average life of backlight only)
Approx. 50,000 hours (at the normal temperature of 25° C)
Backlight auto OFF function Always ON, random setting Brightness adjustment Function switch: 3 levels / Macro: 128 levels Surface sheet material Polycarbonate, 0.3 mm thick POWER lamp ON: Normal (green) Blink: Backlight error
(2) Touch switch specifications
Item Specifications Method Analog resistance film type Number of switches 1024 x 1024 Mechanical life One million activations or more Surface treatment Hard-coated, anti-glare treatment 5 %
(3) Function switch specifications
Item Specifications Number of function switches 8 pcs. Method Matrix resistance film type Mechanical life One million activations or more
Item NP5M0101-5H4 NP5N0011-5H4

Item Specifications D-sub 9-pin (CN1) Applicable standards
Synchronization Asynchronous type Data length 7- or 8-bit Parity None, odd, even Stop bit 1- or 2-bit Baud rate 4800, 9600, 19200, 38400, 57600, 76800, 115.2kbps (187500 bps for MPI connection (Note)) Applications PLC, temperature controller, barcode reader, etc. Modular jack 8-pin (MJ1/MJ2)
RS-232C, RS-485 (2-wire connection)
Applications Screen data transfer (MJ1), PLC, temperature controller, CREC, barcode reader, V-I/O, Multi-link 2, V-Link, etc. USB connector (USB-A/B)
Compliant with USB version 1.1
Baud rate Low speed: 1.5 Mbps, full speed: 12 Mbps Applications Printer (EPSON PM series), CF card reader/writer Applicable standards
Compliant with USB version 1.1
Baud rate Low speed: 1.5 Mbps, full speed: 12 Mbps Applications Screen data transfer, PictBridge-compatible printer Ethernet port 100BASE-TX/ 10BASE-T (LAN)
Compliant with IEEE802.3u (100BASE-TX), IEEE802.3 (10BASE-T)
Baud rate 100 Mbps, 10 Mbps Recommended cable
100 ΩUTP (unshielded twist-pair cable), category 5, max. 100 m long
Applications PLC connection, etc. CF card interface Compliant with CompactFlashTM
Extensional communication port (CN5)
Controller unit connection (The communication unit is not connectable.) Optional unit port (CN7) RGB input/output, video, sound (The optional unit "GU-xx" is necessary.)
(5) Clock and backup memory specifications
Item Specifications Battery specification Coin-type lithium primary cell Backup memory SRAM 512 kbytes Backup period Approx. 5 years (Ambient temperature at 25 °C) Battery voltage drop detection Provided (Internal memory of $s167 allocated) Calendar accuracy Monthly deviation ±90 s (Ambient temperature at 25 °C) (Note)
(backup with battery). Depending on the ambient temperature, the calendar may lose 356 seconds or advance 189 seconds in a month at the maximum. Correct the clock periodically.

Item Specifications Drawing method Exclusive configuration software Drawing tool Name of exclusive configuration software: V-SFT-5 Personal computer: Pentium III 800 MHz or above
(Pentium IV 2.0 GHz or above recommended) OS: Windows98SE/NT4.0/Me/2000/XP/XP64 Edition/Vista 32-bit Capacity of hard disk required:
Free space of approx. 850 Mbytes or more Display: Resolution 1024 x 800 or above Screen color: 16 bits or more
(7) Display function specifications
Characters 1/4-size, 1-byte ANK code Latin 1 ASCII code ASCII code ASCII code 2-byte 16-dot JIS #1, 2 levels - Chinese (traditional)
Hangul (without Kanji) 2-byte 32-dot JIS #1 level - Font Windows font Stroke font (under development) Character size 1/4-size 8 x 8 dots 1-byte 8 x 16 dots 2-byte 16 x 16 dots or 32 x 32 dots Enlargement factor
X: 1 to 8 times, Y: 1 to 8 times Point (Note: 2) : 8, 9, 10, 11, 12, 14, 16, 18, 20, 22, 24, 26, 28, 36, 48, 72 Number of displayable characters
1/4-size 100 characters x 75 lines 1-byte 100 characters x 37 lines 2-byte 57 characters x 37 lines Character properties Display properties: Normal, reverse, blink, bold, shadow, transparent Colors: 65,536 colors (without blinks) / 32,768 colors (with blinks) Graphics Lines: Line, continuous line, box, parallelogram, polygon Circles: Circle, arc, sector, ellipse, elliptical arc Others: Tile patterns Graphic properties Line types: 6 (thin, thick, dot, chain, broken, two-dot chain) Tile patterns: 16 (incl. user-definable 8 patterns) Display properties: Normal, reverse, blink Colors: 65,536 colors (without blinks) 32,768 colors (with blinks) Color selection: Foreground, background, boundary (line)
Gothic, English/Western Europe HK Gothic, English/Western Europe HK Times, Central Europe, Cyrillic, Greek, Turkish. For more information, refer to the “V8 series Reference Manual.” Note: 2) Applicable when Gothic font, Windows font or stroke font is used.

(8) Function performance specifications
Screens Max. 1024 Screen memory Flash memory: Approx. 12.5 Mbytes (Varies depending on the font) Switch 1024 per screen Switch actions Set, reset, momentary, alternate, to light (Possible to press a function switch and a switch on the display at the same time) Lamp Reverse, blink, exchange of graphics 1024 per screen Graph Pie, bar, panel meter and closed area graph:No limitation Statistics and trend graphs: Max. 256 per layer (Note: 2) Data setting
Numerical data display No limitation Character display No limitation Message display Display resolution: 800 x 600: Max. 100 characters (1-byte) No limitation Sampling Sampling display of buffer data (Constant sampling, bit synchronization, alarm logging, time order alarming, alarm
function) Graphic library Max. 2560 Overlap library Max. 1024 Data blocks Max. 1024 Messages Max. 32768 lines Patterns Max. 1024 Macro blocks Max. 1024 Page blocks Max. 1024 Direct blocks Max. 1024 Screen blocks Max. 1024 Data sheets Max. 1024 Screen library Max. 1024 Comments Max. 32768 Device memory map Max. 32 x 8 (PLC1 to PLC8) Time display Provided Hard copy Provided Buzzer Provided, 2 sounds (short beep, long beep) Auto OFF function Always ON, random setting Self-diagnostic function Switch self-test function Communication parameter setting check function Communication check function
Item Specifications

(1) Application performance specifications
Control system Stored program, Cyclic scanning system (default task), periodic task, event task
Input / Output connection method Direct input / output (SX bus)
I/O control system Via SX bus: Synchronous refresh with takt
CPU 32-bit RISC processor
Memory types Program memory, data memory, temporary memory
Programming language IL language (Instruction List) LD language ST language (Structured Text) ST language LD language (Ladder Diagram) FBD language (Function Block Diagram) SFC elements (Sequential Function Chart) Program memory capacity 49152 steps Memory I/O memory 512 words (Up to 256 words, useable I/O memory on the @E.Termina for MC.) General memory 65536 words Retain memory 22528 words 8192 words User FB instance memory 4096 words 8192 words Memory for System FB
6144 words 16384 words Timer 256 points 512 points Integrating timer 64 points 128 points Counter 128 points 256 points Edge detection 512 points 1024 points Others 2048 words 8192 words System memory 512 words No. of tasks Default tasks (Cyclic scanning): 1 Periodic tasks: 4 Event tasks : 4 (Total of 4 tasks when periodic task is used) No. of programs Max. 256 (Max. 128 for one task) Diagnosis function Self diagnosis (memory checking, ROM sum checking), system configuration monitoring, module fault monitoring Secret preserving function By password (set with the support tool) Calendar Available up to 12/31/2069 23:59:59 Precision: ± 27 s/month (at 25 °C, when active) Backup of application program Flash ROM built in CPU module Backup area: Application program, system definition, ZIP file User ROM function Application programs, system definitions, zipped files and compressed projects can be stored in user ROM cards. Backup of data memory
Backup area Retain memory, retain attributed memory (e.g. current value of counter), calendar IC memory, RAS area Battery Lithium primary cell, replacement time: 5 minutes or less (at 25 °C) Backup period Approx. 5 years (at 25 °C)
Item Specifications · Type NP5M0101-5H4/4H4/3H4 NP5N0011-5H4/4H4/3H4

(2) Specific system memory The table below lists system memory specific to @E.Terminal controller unit.
[Expansion annunciator relay area]
Display unit connection status flag
Represents whether a display unit is connected (ON/OFF of display unit power supply). 1: Connected 0: None
[Cause of memory error]
Address Names Descriptions Level SM84 (%MX10.8.4)
Display unit DPRAM error Turns ON when an error occurs in DPRAM for display unit I/F in controller unit.
Address Names Descriptions · Fatal fault

2-2-1 External dimensions and panel cut-out dimensions for the NP5M0101-5H4/NP5N0011-5H4 (Unit: mm)
313.0 +0.5

F 7 F 6 F 5 F 4 F 3 F 2 F 1
radius of bend in the cable is at least 50mm. Plug/unplug the SX bus expansion cable in the perpendicular direction.

2-2-2 External dimensions and panel cut-out dimensions for the NP5M0101-4H4/NP5N0011-4H4 (Unit: mm)

radius of bend in the cable is at least 50mm. Plug/unplug the SX bus expansion cable in the perpendicular direction.

220.5 +0.5

radius of bend in the cable is at least 50mm. Plug/unplug the SX bus expansion cable in the perpendicular direction.

(1) NP5M0101-5H4/NP5N0011-5H4


F 7 F 6 F 5 F 4 F 3 F 2 F 1





* Hidden by the controller unit.
* Hidden by the controller unit. Replace battery by detaching the controller unit.


Seal of the occasion of next
ONL ERR UROM RUN ALM BAT
No. CPU
24V DC +
USER ROM CARD
USB
Version No.
Name plate · battery replacement

Status of the controller unit.
ONL ERR Status of controller unit
OFF OFF Power OFF, system resetting or initializing
Blinks - SX bus standing on
ON OFF Normally running
ON ON Nonfatal fault, at a running
OFF ON Fatal fault at a stop
UROM Green Lights on continuously when the CPU recognizes a user ROM card. Lights on continuously when a user ROM card (compact flash card) is correctly installed in the CPU module and the key switch is set to "3" or "4".
Status of system of the conntroller unit.
RUN ALM Status of system
OFF OFF Power OFF or application program at a stop
ON OFF Normally running
ON ON Nonfatal fault, at a running
OFF ON Fatal fault, at a stop
Blinks - While the CPU is accessing the user ROM
BAT Orange Turned on when data backup battery dropped or disconnected.

Communication (RS-232C, RS-422/485) with a controller is enabled via the serial connector (CN1).
Bottom view Bottom view

The serial connector pins correspond to signals as given below.

6 NC Not used +RTS Request to send (+)
7 RTS Request to send -RTS Request to send (-)
9 NC Not used +5V Use prohibited (Note: 2)
When RS-232C is selected, set the dip switches 5 and 7 to the OFF position. (For more information on the dip switch, refer to “Chapter 2-6”.) Note: 2) When RS-422/485 is selected, +5V is output from pin No. 9.
+5V is used as the power supply for the external terminating resistance for RS-422/485 communication. It cannot be used as an external power supply.
Recommended connector The following connector is recommended for a self-made cable.
DDK's 17JE-23090-02 (D8C) -CG D-sub 9-pin / male / inch screw thread (#4-40UNC) type / with hood / lead- and cadmium-free
Recommended connector

A screen data transfer cable (MJ1 only), temperature controller, barcode reader, CREC, or V-I/O can be connected to the modular jack (MJ1 or MJ2).
Bottom view Bottom view

Pins of MJ1 and MJ2 correspond to signals as given below.


In NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, the dip switch is hidden by the controller unit. Operate the dip switch by detaching the controller unit. The @E.Terminal is equipped with eight (1 to 8) dip switches. When setting the dip switch, turn the power off. Upon delivery, all the dip switches are set to OFF.
Rear view Rear view

1 2 3 4 5 6 7 8
MJ2 (modular jack 2) terminating resistor
CF auto-uploading Not used
CN1 +RD/-RD terminating resistor at pins 1 and 2 MJ1 (modular jack 1) terminating resistor
CF card interface cover access control
CN1 +SD/-SD terminating resistor at pins 3 and 4
Set the dip switch number 1 to the ON position when auto-uploading a screen data file saved on a CF card.
Dip switch · Procedure

Dip switch number 2 (CF Card interface cover access control)
When the dip switch number 2 is set to the ON position, access to the CF card is possible whether the cover is opened or not. In case access to the CF card is disabled because of damage of the CF card interface cover, set the dip switch number 2 to the ON position. Normally keep it in the OFF position. Caution
With the dip switch number 2, the LED status when the CF card interface cover is opened can be set.

Not lit Access to the CF card is not performed. CF card can be removed.
Lights up in red Accessing the CF card. After the access is finished, the LED goes off.
ON Lights up in red Access to the CF card is possible at all times.
Dip switch number 3, 4 (Not used)
Set the dip switch number 3 and 4 to OFF.
Dip switch number 5, 6, 7, 8 (Terminating resistor setting)
* Detaching controller unit To operate the dip switch in NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, remove the controller unit. Remove mounting screws at three places to remove the controller unit from the display unit. Be careful not to drop or lose the mounting screws.

Mounting screws at three places M3 screws thread, Tightening torque:
0.5 to 0.7N·m

(1) Mounting procedure 3-1 (2) Mounting angle 3-1
(1) Power supply cable wiring 3-2 (2) Grounding 3-4
Page

3-1 Mounting Procedure



* When the @E.Terminal unit is attached to the mounting panel, the fixtures and frame grounds (FG) are connected. To prevent static electricity, be sure to connect the mounting panel to the frame ground.
(2) Mounting angle Install the unit within the angle of 15° to 135° as shown on the right.

(1) Power supply cable wiring Power supply terminal blocks of the display unit and the controller unit are connected with each other with a cable by default. Use one power supply terminal block to connect the power supply cable.
Connect the power supply cable to the power supply terminal block of the controller unit. Connect the power supply cable to the power supply terminal block of the display unit.

Keep the distance between the DC power supply and the power supply module as short as possible, and the cable must be twisted densely.

FG
Do not bundle up and do not close.
* Noise filter is not required for controller unit hardware version “03” or later. Noise filter is not attached as accessory with above version.
DC power supply

3.7mm
φ 3.7mm
M3.5 0.8N·m AWG18 - 16
3.7mm
φ 3.7mm
NP5M0101-3H4 NP5N0011-3H4 M3.5 1.2N·m AWG16 - 14
7.1mm or less
7.1mm or less
Maker Form Types Cable size AWG mm2
36467 22 to 18 0.3 to 0.8 mm2 34104 34105
0.3-3 24 to 20 0.2 to 0.5 mm2 0.3-3N 1.25-3
22 to 16 0.3 to 1.3 mm2 1.25-3N 1.25-3S 1.25-3.5N 1.25-3.5S 2-3N 16 to 14 1.3 to 2.0 mm2
0.3Y-3 24 to 20 0.2 to 0.5 mm2
22 to 16 0.3 to 1.3 mm2 1.25Y-3N 1.25Y-3S 1.25Y-3.5 2Y-3 16 to 14 1.3 to 2.0 mm2 2Y-3.5S AT1-10 22 to 16 0.3 to 1.3 mm2
AT2-10 16 to 14 1.3 to 2.0 mm2
SRA-20-3.2 22 to 18 0.3 to 0.8 mm2 SRA-20T-3.2
0.4-3 26 to 22 0.2 to 0.3 mm2
1.25-3 22 to 16 0.3 to 1.3 mm2 Angle edge terminals
VR1.25-3 VD1.25-3 VD2-3S 16 to 14 1.3 to 2.0 mm2

Other equipment @E.Terminal Other equipment @E.Terminal Other equipment @E.Terminal
* When the @E.Terminal unit is attached to the mounting panel, the fixtures and frame grounds (FG) are connected. To detach the FG terminal from the ground, attach the insulating sheet to the fixtures and the mounting panel for insulation.
(2) Grounding

4-1-1 Daily inspection 4-1
4-1-2 Periodical inspection 4-1
(1) Battery specification 4-2 (2) Precautions 4-2 (3) How to replacement battery 4-2
4-3-1 Ordering notes 4-4
4-3-2 Free-of-charge warranty period and scope of warranty 4-4
4-3-3 Service costs 4-4
Page

4-1 Inspection and Maintenance
4-1-2 Periodical inspection Inspect the following points periodically.

When the time comes to replacement the battery, replace it for a new one even if battery error is not displayed. Also, when low battery voltage of the display unit and the controller unit is discovered, replace the battery for a new one immediately. Replacement the batteries of the display unit and the controller unit at the same time.
Battery specification Lithium primary cell
Backup time Approx. 5 years (Ambient temperature at 25 °C)
Battery boltage drop detection funnction
Required time in the battery replacement
5 minutes or less
Battery specification Coin-type lithium primary cell
Backup time Approx. 5 years (Ambient temperature at 25 °C)
Battery boltage drop detection funnction
Provided (Internal memory of $s167 allocated)
Required time in the battery replacement
3 minutes or less
(3) How to replacement battery
(1) Battery specification · Items Specifications · Items Specifications


Mounting screws at three places M3 screws thread, Tightening torque:
0.5 to 0.7N·m


the unit is turned off. If it is not possible to replace within three minutes, make a backup copy of data in the SRAM.

4-3-1 Ordering notes When ordering electrical and control equipment (or requesting price estimates), the following general notes are to be observed, unless otherwise specified in the estimation paper, contract paper, catalogs, or specifications. When the product is delivered, check the contents of the package as soon as possible. Even before inspection, use caution on storing and using the product safely.
[Free-of-charge warranty period] (1) This product is covered by a warranty for a period of one year from the date of purchase or 18 months from the date of
manufacture described in the nameplate, whichever comes earlier. (2) This warranty period may not be applied if the operating environment, operating condition, operating frequency, or
number of operations affects the operating life of the product. (3) The warranty period for the product section repaired by Fuji Electric service sector is six (6) months from the date of
completion of repair.
[Warranty period] (1) If a failure judged to be the responsibility of Fuji Electric occurs during the warranty period, the failed section of the
product is replaced or repaired on a free-of-charge basis at the site of purchase or delivery of the product. However, the following failures are not covered by this warranty.
product (damages to or loss of machinery and equipment, or passive damages) are not covered by this warranty.
[Repair period after production stoppage and supply period of spare parts (maintenance period)] As for retired models (products), Fuji Electric performs repair work within seven (7) years from the date of retirement. As for major spare parts for repair, Fuji Electric also performs repair work within seven (7) years from the date of retirement. With electronic parts, however, difficulty in procurement or production may be anticipated because of short life cycles and therefore repair or spare parts supply may be difficult even during the warranty period. For details, please contact Fuji Electric sales office or service sector.
4-3-3 Service costs The price of the product does not include maintenance and servicing costs, such as the cost of dispatching an engineer to the customer. The customer will be charged for actual expenses in the following cases. (1) Guidance for installation and adjustment, and attendance at a test operation (2) Maintenance, inspection, adjustment, and repair (3) Technical guidance and technical education

(No contents installed)
Page

(No contents installed)
When you make new project for controller of @E.Terminal (No contents installed) by personal computer loader (SX- programmer Expert/ Standard), download template for new project from our homepage. The project for controller of @E. Terminal for MC is stored in backup CD.
(1) Download template Access to our homepage, download from [Software libraries] of [Programmable controllers]. (Address: http://www.fesys.co.jp/eng/)
(3) Order to register template to SX-Programmer Standard. When you click [File]-[New], [Template selection] screen is displayed. Right click mouse under description area, and select [import]. Select template file at [import] dialog, and click open.



Template of is registered at [Template selection] screen.
(4) Notes In [Execution band ratio setting] of [CPU running definition], proportion of [Built-in] must be set as “0.”


Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032,Japan Phone: +81-3-5435-7280 Fax: +81-3-5435-7425 URL http://www.fesys.co.jp/eng/
Printed on recycled paper.
Printed in Japan 2008-12 FIS
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.