SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER 8 2 8 By SHERWOOD INDUSTRIES LTD. B Vent OWNERS MANUAL Installation And Operating Instructions For Models: 828 BV. FS. (Freestanding) 828 BV. INS. (Insert) PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions.
TABLE OF CONTENTS 1 Code Approvals ............................................................................................................... .................... 3 2 Specifications ................................................................
FOR INSTALLATIONS ABOVE 2000 FEET • In Canada, these appliances are certified for altit udes of 0-2,000 feet and must be derated by 10% for installation at elevations be tween 2,000 and 4,500 feet. • In the USA, these appliance are certified for elevati ons up to 2,000 feet.
4. DECIDING WHERE TO LOCATE YOUR FREESTANDING STOVE 1. The stove should be located out of tr affic and away from f urniture and draperies. 2. This stove should have sufficient access for its safe operation and maintenance.
* As specified in CGA B149 Installation Codes (1991) Note: Local Codes or Regulations may require different clearances. 5. ASSEMBLY AND INSTALLATION INSTRUCTIONS PREPARATION FOR INSTALLATION • Remove the packaging from the appliance, pedestal or surround panels, check to make sure there is no damage.
13. Re-attach the hinged side flaps by sandwiching the surround panels between th e mounting brackets and the hinged side flaps. secure with screws. 14. Re-install the stove top by inserting the locating screws, previously put into the surr ound panel top, through the holes in the back of the stov e top.
6. ELECTRICAL REQUIREMENTS The ENVIROGAS 828 Series will operate w it hout an external electrical power supply . This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operat e the main burners. CAUTION: Label all wires prior to disconnection when servici ng controls.
7. GAS LINE CONNECTION AND TESTING WA RNING: Only persons licensed to w ork with gas piping can make the gas connections to this appliance. This appliance is equipped with a 3/8” stainless steel flex line from the valve. This line ma y be routed through the hole in the rear of the pedestal, or on inserts, routed through the fire box sides.
8. VENTING WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM. IT IS ALSO DE SIGNED TO DRAW ROOM AIR FOR PROPER HEAT CIRCULATION FROM THE SIDES OF THE UNIT. BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY CAN CREATE HAZARDOUS SITUATIONS, EITHER THROUGH POOR VENTING OR BY OVERHEATING.
constructed out of non-combust ible materials. Make sure that all chimney clean outs are tightly fitti ng and will not permit air to leak into the chimney. Remove the vent collar plate from the top of the insert and connect it s ecurely with at least 3 sheet metal screws and a 4" hose clamp.
For best venting perfor mance, we recommend total vent height of 10ft (3m) to 30f t (9m). Total horizontal length depends on the number of elbows used. The venting should never slope down. 1/4" rise per 2' horizontal is recommended. If practical, it is best have shor ter horizontals and fewer elbows.
10. INSTALLATION OF LOG SET and EMBERS A. INSTALLING THE GLOWING EMBERS A bag of ceramic fiber ember s is provided for use on the front burner tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required.
11. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIO NS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot which must be lit by hand by following these instructions exactly.
12. ROUTINE MAINTENANCE Periodically check to ensure that the "B-Vent" venting system is clear and that a negative draft is pr esent when the unit is operating. On fireplace insert models there is a draft inspection tube the opening is located on the right hand side behind the hinged side.
13. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not arc to the pilot after repeated pressing of spark ignitor Defective piezo ignitor Check connections to ignitor -If ignitor connectio.
14. PARTS AND ACCESSORIES Service Parts available from your local ENVIROGAS Dealer. PART # DESCRIPTION 828-001 Convection Blower 828-002 Heyco Strain Relief 828-003 2-Speed Fan Switch 828-004 Eurosit .
18 15. WARRANTY Sherwood Industries Ltd. offer s a *Lifetime Warranty on t his gas product. The lifetime warrant y covers the appliance for a period of seven years f rom the date of installat ion.
16. INSTALLATION DATA SHEET The following information must be recorded by the inst aller for w arranty purposes and future reference. Envirogas Model: EG-828 INSERT BV.
20.
An important point after buying a device Enviro ENVIRO GAS 828 BV. FS. (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro ENVIRO GAS 828 BV. FS. yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro ENVIRO GAS 828 BV. FS. - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro ENVIRO GAS 828 BV. FS. you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro ENVIRO GAS 828 BV. FS. will certainly help you make a decision on the purchase.
If you already are a holder of Enviro ENVIRO GAS 828 BV. FS., but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro ENVIRO GAS 828 BV. FS..
However, one of the most important roles played by the user manual is to help in solving problems with Enviro ENVIRO GAS 828 BV. FS.. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro ENVIRO GAS 828 BV. FS. along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center