EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 GENERAL ST A TEMENT IMPORT ANT : The information cont ained in this manual is critical to the correct operation and main- tenance of the EMI cassette and should be read by all persons responsible for the installation, start up and maintenance of the unit.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 2 displayed on the fascia mounted receiver . The microproces- sor also limits the number of compressor starts per hour to reduce wear on the compressor .
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 3 1. Position the thermostat approximately 5 ft. above floor level. 2. Do not position thermostat where it can be directly affected by the unit’s discharge air stream. 3. Avoid external walls and draft s from windows and doors.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 4 SECTION THROUGH F ASCIA FASCIA BLANKING PIECE 3. Condensate pipework should slope downwards in the direction of water flow with a minimum gradient of (1” per 10’). There must not be any uphill gradients other than in the first 18” of pipework from the Cassette.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 5 E LE CT R ICAL S P E CIF ICATIO N S SM A L L M E DIU M L A R GE P OW E R SU P P LY 230V / 1P H /60H Z 230V /1P H /60H Z 230V / 1P H /60H Z F U LL LO A D A M P S A 0.4 0.6 0.9 MI N. CIRCUIT A MP A CITY ( MCA ) A 0 .
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 6 STA RT U P SH E E T E XA M PLE E N VIR OM ASTE R IN TE R N A TION AL LL C 5780 SU C C ESS D RIVE R O M E , N Y 1 34 4 0 T EL: 1 -800-22 8-9364 F A X: 1 -800-23 2-9364 H T T P :/ / WWW.E N VIR OM A S T E R .
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 7 CAH/ W TECHNICAL DAT A R E F R I G E R A T I O N 09- 12 15 18- 24 30-3 6 42- 48 NUM BE R O F CIRCUI T S 1 1 1 1 1 R E FR IGE R A N T T Y PE R 2 2.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 8 SMALL CABINET • CAH 9,000 - 12,000 • CAHW 9,000 ONL Y • CAF 8,000 - 12,000 • CAF4 8,000 ONL Y EMI CASSETTE DIMENSIONS.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 9 MEDIUM CABINET • CAH 15,000 - 24,000 • CAHW 12,000 - 24,000 • CAF 18,000 - 20,000 • CAF4 12,000 - 20,000 CAS S ETT E DIM ENS IO NS ( I NC.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 0 The red indicator will be lit when the in-built time clock func- tion is activated. T o disable the time clock, all start/stop times must be set to 12am via the transmitter (see program- ming instructions in this installation manual).
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 1 DISPLA Y INDICA T ORS TRANSMIT INDICA TOR Flashes when system settings are transmitted. MODE INDICA TOR Highlights Mode of Operation. F AN MODE INDICA TO R Highlights Fan Speed. CLOCK/TIMER DISPLA Y Shows current day , time, or weekly program Stop/Start times.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 2 SETTING UP THE BUIL T -IN TIME CLOCK HOW TO SET THE PRESENT TIME 1. Press CLK/Timer: “Clock Set” highlights. NOTE: Display will stop flashing after 15 seconds. 2. Select Hour with either (+) or (-).
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 3 IMPORT ANT : As of 12/01/04 EMI air handlers will be manu- factured with a low Volt transformer installed. At the same time, EMI outdoor condensers will be manufactures with- out a low Volt transformer .
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 4 TRANSMITTER F AILURE (MICRO UNITS ONL Y). Try new batteries first, if receiver bleeps on transmitting signal, trans- mitter is OK. If no response press On/Off button on unit fascia. If the unit responds to the On/Off button transmitter is faulty .
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 5 HIGH CONDENSA TE LEVEL TRIP . Drain the condensate tray and investigate. See section “Condensate high Level/” erating pressures. Check filter condition. (See maintenance instructions for more information).
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 6 NO HEA TING (E lectric Heat) POSSIBLE CAUSES/REMEDIES INCORRECT MODE SETTING (MICRO UNITS ONL Y) – Check that the transmitter Mode is set to Heat or Auto Mode. SET POINT TOO LOW – Check the set point on the trans- mitter or wall mounted thermostat and adjust if necessary .
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 7 MAINTENANCE EVERY 3 MONTHS: Check the air filter condition and clean if necessary (see below). EVERY 6 MONTHS: Same as 3 months plus clean conden- sate tray with biocide suitable for polystyrene and clean fas- cia.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 8 TERMINAL BLOCK INSTRUCTION FOR THE CONNECTION OF HIGH/LOW VOL T AGE WIRES When connecting line and/or low voltage wires to the CAH terminal block(s) a 3/32-screw driver (thermostat type) is required.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 9 1. Cassette Chassis 2. Evaporator Assembly 3. Electric Heater Element Assembly 4. Condensate Tray 5. Condensate Tray Supports (2) 6. Condensate Pump 7. High Level Switch 8. Condensate Pump Assembly 9.
EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 2 0 1 8 5 7 10 18 19 20 14 3 2 9 4 6 16 13 12 15 11 17 1. Cassette Chassis 2. Evaporator Coil 3. Condensate Tray 4. Condensate Tray Support 5. Condensate Pump 6. High Level Switch 7. Fan & Motor Assembly 8.
An important point after buying a device EMI WLCA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought EMI WLCA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data EMI WLCA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, EMI WLCA you will learn all the available features of the product, as well as information on its operation. The information that you get EMI WLCA will certainly help you make a decision on the purchase.
If you already are a holder of EMI WLCA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime EMI WLCA.
However, one of the most important roles played by the user manual is to help in solving problems with EMI WLCA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device EMI WLCA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center