Installation and Use
February 2010

All rights reserved.
Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2010 Emerson Electric Co. All other trademarks are the property of their respective owners.
Intel® is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
Java™ and all other Java-based marks are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries.
Microsoft®, Windows® and Windows Me® are registered trademarks of Microsoft Corporation; and Windows XP™ is a trademark of Microsoft Corporation.
PICMG®, CompactPCI®, AdvancedTCA™ and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI Industrial Computer Manufacturers Group.
UNIX® is a registered trademark of The Open Group in the United States and other countries.
While reasonable efforts have been made to assure the accuracy of this document, Emerson assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to a Emerson website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise altered without the permission of Emerson,
It is possible that this publication may contain reference to or information about Emerson products (machines and programs), programming, or services that are not available in your country. Such references or information must not be construed to mean that Emerson intends to announce such Emerson products, programming, or services in your country.
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply unless otherwise agreed to in writing by Emerson.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and Documentation clause at DFARS 252.227-7014 (Jun. 1995).
Emerson Network Power - Embedded Computing GmbH
Lilienthalstr. 15
© 2010 Emerson · 85579 Neubiberg-Munich/Germany


Table 1-1 Mechanical Specifications of RTM-ATCA-7350 13 Table 1-2 Standard Compliances 14 Table 1-3 Product Nomenclature 14 Table 1-4 Available Board Accessories 15 Table 2-1 Environmental Requirements 18 Table 2-2 Power Requirements 19 Table 3-1 Indicators on the RTM-ATCA-7350 Face Plate 39 Table 3-2 USB Port Pin Assignment 42 Table 3-3 VGA Port Pin Assignment 43 Table 3-4 PIN 30 Pinout 44 Table 3-5 PIN 31 Pinout 44 Table 3-6 PIN 32 Pinout 45 Table 4-1 Indicators Provided by the GE Daughter Card 48 Table 4-2 Indicators Provided by the FC Daughter Card 49 Table A-1 Emerson Network Power - Embedded Computing Publications 51 Table A-2 Related Specifications 51

List of Tables

Figure 2-1 Wearing the ESD-Preventive Wrist Strap 22 Figure 2-2 Removing the Filler Blade 23 Figure 2-3 Structure of RTM-ATCA-7350 26 Figure 2-4 Installing the GE Daughter Card 27 Figure 2-5 Installing RTM-ATCA-7350 31 Figure 2-6 Removing RTM-ATCA-7350 33 Figure 2-7 Connecting the KVM Cables to RTM-ATCA-7350 34 Figure 2-8 Connecting the Network Cables to RTM-ATCA-7350 35 Figure 2-9 Connecting the Optical Fibers to RTM-ATCA-7350 36 Figure 3-1 Face Plate of RTM-ATCA-7350 38 Figure 3-2 Structure of RTM-ATCA-7350 40 Figure 3-3 Connectors and Indicators of RTM-ATCA-7350 41 Figure 3-4 RTM-ATCA-7350 Front Plate USB Connector Pinout 42 Figure 3-5 RTM-ATCA-7350 Front Plate VGA Port Pinout 42 Figure 4-1 Block Diagram of RTM-ATCA-7350 47 Figure 4-2 GE Daughter Card 48 Figure 4-3 FC Daughter Card 49

List of Figures

Overview of Contents
This manual is intended for the users who install and configure the RTM-ATCA-7350 of the server blade. The user must be a professional engineer in the server device field, who has been trained and is able to identify danger levels when operating the device.
This manual describes the structure, appearance, functions, technical specifications, precautions, and installation procedure of the RTM-ATCA-7350. In addition, it also provides information of the components supported by the RTM-ATCA-7350 and describes how to install and replace the components.
This manual is divided into the following chapters and appendix.
z Chapter 1, Introduction, on page 13
z Chapter 2, Hardware Preparation and Installation, on page 17
z Chapter 3, Controls, LEDs and Connectors, on page 37
z Chapter 4, Functional Description, on page 47
z Appendix A, Related Documentation, on page 51
This document uses the following abbreviations:

The following table describes the conventions used throughout this manual.
About this Manual





This manual has been revised and replaces all prior editions.
About this Manual

We welcome and appreciate your comments on our documentation. We want to know what you think about our manuals and how we can make them better.
Mail comments to us by filling out the following online form: http://www.emersonnetworkpowerembeddedcomputing.com/ > Contact Us > Online Form
In "Area of Interest" select "Technical Documentation". Be sure to include the title, part number, and revision of the manual and tell us how you used it.
About this Manual

1.1 Overview of RTM-ATCA-7350
The ATCA-7350 Rear Transition Module (RTM) of the server blade (hereinafter referred to as RTM-ATCA-7350) must work with the server blade ATCA-7350. RTM-ATCA-7350 provides external interfaces for the connected server blade.
RTM-ATCA-7350 provides the following functions:
z RTM-ATCA-7350 provides two daughter card connectors. RTM-ATCA-7350 supports the following daughter cards:
– Gigabit Ethernet (GE) daughter card
– Fiber Channel (FC) daughter card The daughter cards provide external interfaces for the server blade.
z As a manageable module of the server blade, RTM-ATCA-7350 is managed by the Intelligent Platform Management Controller (IPMC) of the server blade.
z The IPMC monitors the working status of RTM-ATCA-7350. In addition, the Field Replaceable Unit (FRU) data is stored in the EEPROMs on the RTM itself and the daughter cards.
The following table lists the mechanical specifications of RTM-ATCA-7350.
Table 1-1 Mechanical Specifications of RTM-ATCA-7350
Maximum weight 0.76 kg
Length x width x height 322.3 mm x 70 mm x 29 mm
Item Specification

The product is designed to meet the following standards.
Table 1-2 Standard Compliances
EN 60950-1
IEC 60950-1
CAN/CSA C22.2 No 60950-1
EMC requirements (legal) on system level (predefined Emerson Network Power Embedded Computing system)
EN 55022
EN 55024
AS/NZS CISPR 22
EN 300 386
NEBS Standard GR-1089 CORE
ETSI EN 300019 series
Defines mechanics, blade dimensions, power distribution, power and data connectors, and system management
When ordering board variants or board accessories, use the order numbers given on the following pages.
The following table explains the product nomenclature used for the available board variants.
Table 1-3 Product Nomenclature
RTM-ATCA-7350 RTM FOR THE ATCA-7350 BLADE WITH 10G FABRIC SUPPORT (ROHS 5/6)
RTM-ATCA-7350-GE RTM FOR THE ATCA-7350 BLADE WITH 2 GE INTERFACES (ROHS 5/6)

Table 1-3 Product Nomenclature (continued)
RTM-ATCA-7350-2GE RTM FOR THE ATCA-7350 BLADE WITH 4 GE INTERFACES (ROHS 5/6)
RTM-ATCA-7350-FC RTM FOR THE ATCA-7350 BLADE WITH 2 FC INTERFACES (ROHS 5/6)
As of the printing date of this manual, the following board accessories were available.
Table 1-4 Available Board Accessories
Board Accessories Order Number
Gigabit Ethernet (GE) daughter card MEZC-RTM-7150-GE
Fiber Channel (FC) daughter card1 MEZC-RTM-7150-FC
Board Accessories Introduction · Order Number Description

Introduction Board Accessories

2.1 Overview
This chapter describes:
z Unpacking and inspecting RTM-ATCA-7350
z Precautions during the operation
z Preparations before installation
z Installing and replacing daughter cards
z Connection of external cables

Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.
To inspect the shipment, perform the following steps.
z Installation procedure · z Removal procedure

Hardware Preparation and Installation Environmental and Power Requirements
The product is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately.
The following environmental and power requirements are applicable to the board.
Table 2-1 Environmental Requirements
Temperature +5ºC (41ºF) to +40ºC (104ºF) (normal operation) according to NEBS Standard GR-63-CORE
-40ºC (-40ºF) to +70ºC (158ºF) (may be further limited by installed accessories)
-5ºC to +55ºC (short term operation) according to NEBS Standard GR-63-CORE
Temp. Change +/- 0.25ºC/min or 15ºC/h (59ºF/h) according to NEBS Standard GR-63-CORE
+/- 0.25ºC/min or 15ºC/h (59ºF/h)
Rel. Humidity 5% to 85% non-condensing according to Emerson Network Power Embedded Computing-internal environmental requirements
5% to 85% non-condensing according to Emerson Network Power Embedded Computing-internal environmental requirements
Vibration 1.0g from 5 to 100 Hz and back to 5 Hz at a rate of 0.1 octave/minute
5-20 Hz @ 0.01 g2/Hz
20-200 Hz @ -3.0 dB/octave
Random 5-20 Hz @ 1 m2/Sec3
Random 20-200 Hz @ -3 m/Sec2
Shock Half-sine, 11 m/Sec, 30mSec/sec2 Blade level packaging
Half-sine, 6 mSec at 180 m/Sec2
Requirement Operating Non-Operating · Altitude

Power Requirements Hardware Preparation and Installation
Table 2-1 Environmental Requirements (continued)
Free Fall 1,200 mm (Packaged) /all edges and corners
1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging)
25mm (unpackaged) per GR-63-CORE
Table 2-2 Power Requirements
Power supply Provided by the server blade
Maximum power consumption 14.2 W

Personal Injury Power and communication cables Touching power and communication cables that are energized may cause injuries. Make sure that the cables cannot be touched while the product is operating.
Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.
Requirement Operating Non-Operating · Requirement Operating

Hardware Preparation and Installation Ejector Handles
Module Damage If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane. Do not exert too much force when you insert the blade.
z Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent the static electricity from hurting you or damaging the device.
z Keep your personal objects such as your clothes away from RTM-ATCA-7350. To prevent the static electricity on clothing, you need to put on antistatic clothing.
z RTM-ATCA-7350 is installed in the slot paired with the server blade slot at the back side of the shelf. RTM-ATCA-7350 is powered from the payload power of the front board. You should install RTM-ATCA-7350 before payload power of the front board is turned on. Hot swap of the RTM-ATCA-7350 while under power is not supported.
z Hold the ejector handles and the face plate when you insert or remove RTM-ATCA-7350. Do not touch the components inside of the blades.
z Keep the blade vertical when you install RTM-ATCA-7350. Align the blade with the slot and then insert it in the shelf.
RTM-ATCA-7350 is powered by the server blade in the slot paired with the RTM-ATCA-7350 slot. RTM-ATCA-7350 does not support hot swap. As shown in Figure 1-4, the face plate of RTM-ATCA-7350 provides an upper and a lower ejector handles. The ejector handles help to insert, remove, fasten, power on, and power off RTM-ATCA-7350.
Static electricity may hurt you or damage the device. To minimize the damage, pay attention to the following points:
z Before you operate the device, wear the ESD-preventive wrist strap. Both terminals of the ESD-preventive wrist strap must contact well. One terminal touches your bare skin, and the other is inserted in the jack at the front or back side of the shelf. For details on how to wear the ESD-preventive wrist strap, refer Wearing the ESD-Preventive Wrist Strap on page 21.
z Avoid moving your body as much as possible. Movement gathers static electricity around you.
z Do not touch the solder point, pin, or bare circuit.
z Do not leave the device in the place where others can operate it.

Installation Preparations Hardware Preparation and Installation
z Install the device at once after you take it out of the antistatic package. If you need to lay down the device, place it back in the antistatic package. Do not lay the device on the shelf or cabinet.
z Monitor the temperature and humidity of the equipment room. Warm air decreases the humidity and increases the static electricity in the room.
The installation preparations process includes:
z check the installation environment
z wear the ESD-preventive wrist strap
z remove the blank filler panels
z unpack and check the RTM-ATCA-7350 suite
z Electrostatic discharge can damage circuits or shorten their life.
z The ESD-preventive wrist strap prevents only the static electricity on your body from damaging the blade. To prevent the static electricity on your clothes, it is recommended to wear the antistatic clothes. Additionally, you have to make sure that the cabinet and shelf are properly grounded - for details, refer to the corresponding system documentation.

Hardware Preparation and Installation Wearing the ESD-Preventive Wrist Strap
To wear the ESD-preventive wrist strap, proceed as follows:
Figure 2-1 Wearing the ESD-Preventive Wrist Strap


Removing Filler Blades Hardware Preparation and Installation
After a filler blade is removed, place it in the equipment room or other moisture-proof and dust-proof places.
You should install a blank filler blade in the slot after removing the blade. Otherwise, it may effect the ventilation, heat dissipation, electromagnetic shielding and dust prevention of the shelf.
If this is the first installation for the shelf, the blade is fully configured and the shelf is not powered on, you can remove all the filler blades. Then, install blades in the slots in order. This document takes the first installation as an example.
If you want to install multiple blades in the shelf that is powered on, you can remove a filler blade and then install a blade one by one.
If the slot is occupied with a filler blade you have to remove it first.
To remove the filler blade, proceed as follows:
Figure 2-2 Removing the Filler Blade


Hardware Preparation and Installation Installing and Replacing Daughter Cards
2.6.1 Precautions
Incorrect installation or removal of additional devices or modules may damage the product or the additional devices or modules. Before installing or removing additional devices or modules, read the respective documentation.

Personal Injury Power and communication cables Touching power and communication cables that are energized may cause injuries. Make sure that the cables cannot be touched while the product is operating.
Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life. Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.
Do not exert too much force when you insert the blade. If the blade is not fully aligned with the interface in the backplane, too much force may twist the pins on the blade or backplane.
z Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent the static electricity from hurting you or damaging the device.
z Keep the area where the components reside clean and keep the components away from the heat-generating devices, such as radiators.

Preparations Hardware Preparation and Installation
z Ensure that your sleeves are tightened or rolled up above the elbow. For safety purpose, it is not recommended to wear jewelry, watch, glasses with metal frame, or clothes with metal buttons.
z Do not exert too much force, or insert or remove the components forcibly. Avoid damage to the components or plug-ins, for example, the pins are bent or get short circuit.
Before you install or replace a component, make the following preparations
z Confirming the feasibility of the operation
– There are available spare parts of the component to be installed or replaced in the equipment warehouse. When the available spare parts are in short supply, contact Emerson Network Power Embedded Computing for help in time.
– Make sure that the new component is in good condition, without defects such as oxidation, chemical corrosion, missing component, or transportation damage.
– By reading this document, you are familiar with how to install and replace the component and master the skills required by the operation.
z Checking the environment Make sure that the shelf, power supply, temperature, and humidity meet the operating requirements of the blades and components. For details, refer to ATCA-7350 Installation and Use Manual and other related documents.
z Preparing spare parts and tools
– Prepare the component to be installed or replaced. When you hold or transport the component, use the special antistatic package. In addition, you need to tidy, record, and repair the component during routine maintenance.
– Prepare the cross screwdriver, screws, plastic supports, cooling gel, and ESD- preventive wrist strap. The supplier provides a list of tools and negotiates with you to decide the tool provider.
z Confirming installation or changing positions Confirm the positions of the cabinet, the shelf, and the slot where RTM-ATCA-7350 is installed. Then, stick a label on the face plate of RTM-ATCA-7350 to avoid wrong operation.
z Others If a serious problem occurs and cannot be solved when you install or replace the component, contact Emerson Network Power Embedded Computing for technical support.
This manual considers the GE daughter card providing two external Ethernet interfaces as an example, and describes how to install the daughter card on and remove it from RTM-ATCA- 7350.

Hardware Preparation and Installation GE Daughter Card
When the GE daughter card is used with the RTM-ATCA-7350 it can be installed on the daughter card connector J1, J2. The default position as used on the RTM-ATCA-7350-GE is position J2.
Figure 2-3 Structure of RTM-ATCA-7350

To install the GE daughter card, proceed as follows.

GE Daughter Card Hardware Preparation and Installation
Figure 2-4 Installing the GE Daughter Card


Hardware Preparation and Installation FC Daughter Card
After installation, check if RTM-ATCA-7350 can be powered on and work normally. Use the network cable to connect RTM-ATCA-7350 to the external network. Check if the network is connected properly and monitor whether the network port indicator is normal.
To replace the GE daughter card, proceed as follows.
After replacement, check if RTM-ATCA-7350 can be powered on and work normally. Use the network cable to connect RTM-ATCA-7350 to the external network. Check if the network is connected properly and monitor whether the network port indicator is normal.
This section describes how to install the daughter card on and remove it from RTM-ATCA-7350.
When the FC daughter card is used with the RTM-ATCA-7350 it can be installed on the daughter card connector J1. The RTM-ATCA-7350 provides space for one FC daughter card. Use of the FC daughter card excludes use of the GE daughter card.

FC Daughter Card Hardware Preparation and Installation
To install the FC daughter card, proceed as follows.
After installation, check if RTM-ATCA-7350 can be powered on and work normally. Use the optical fiber to connect RTM-ATCA-7350 to the external storage system. Check if RTM-ATCA- 7350 can transmit data normally and monitor whether the FC status indicator is normal.
To replace the FC daughter card, proceed as follows.

Hardware Preparation and Installation Installing and Removing the RTM-ATCA-7350
After replacement, check if RTM-ATCA-7350 can be powered on and work normally. Use the optical fibre to connect RTM-ATCA-7350 to the external storage system. Check if RTM-ATCA- 7350 can transmit data normally and monitor whether the FC status indicator is normal.
2.7.1 Installing RTM-ATCA-7350
Product Damage You can install RTM-ATCA-7350 into a system if the front blade is already installed or if it is not installed. In case the front blade is already installed, its payload has to be powered down first.
The following procedure describes the installation of RTM-ATCA-7350. It assumes that your system is powered on. If your system is powered off, you can disregard the blue LED and thus skip the respective step. In this case it is a purely mechanical installation. The same applies to an installation without an installed front blade. In this case disregard the LEDs and skip the respective step.

Installing RTM-ATCA-7350 Hardware Preparation and Installation
The blue LED blinks indicating that the shelf manager is informed about the desire of the blade to power down the payload of the front blade and the power-down process is ongoing.
Figure 2-5 Installing RTM-ATCA-7350


Hardware Preparation and Installation Removing RTM-ATCA-7350
Product Damage You should power off the front blade before removing RTM-ATCA-7350.
To remove RTM-ATCA-7350, proceed as follows:

Connecting External Cables Hardware Preparation and Installation
Figure 2-6 Removing RTM-ATCA-7350

After RTM-ATCA-7350 is installed in the shelf, you can connect the keyboard, video, and mouse (KVM) cables.
If RTM-ATCA-7350 is configured with the GE daughter card or FC daughter card, it provides the external GE network ports or external FC interfaces. Network cables or optical fibers can be connected to RTM-ATCA-7350. You can choose to use one or more daughter cards according to actual applications.
Refer Daughter Cards on page 47, for the functions of the daughter cards of RTM-ATCA- 7350.

Hardware Preparation and Installation Connecting KVM Cables

z There is a back cable trough at the back side of the shelf. You need to arrange and identify all cables and then bind and fasten them in the back cable through after connecting them.
z If you use excessive force when installing cables, the cables may be damaged.
z Do not exert too much force when you insert or remove the cables. Do not twist or tear the cables in any condition.
The figure below shows the method of connecting the Keyboard, Video, Mouse (KVM) cables to RTM-ATCA-7350 when connecting PS/2 compatible keyboard and mouse using a PS/2-USB converter. USB based keyboard and mouse can also be attached to the RTM by using a USB hub.

Product Damage You have to use matching interfaces for the KVM cables. Use a PS/2-USB converter when connecting to PS/2 based keyboard and mouse cables. Use a USB hub when connecting to USB based keyboard and mouse cables.
Figure 2-7 Connecting the KVM Cables to RTM-ATCA-7350


Connecting Network Cables Hardware Preparation and Installation

Electromagnetic Radiation Make sure that the cable and connectors of the network cable are with shielding function and that both ends of the shielded layer of the network cable are grounded. It is recommended that the network cable is grounded through the metal cover of the network port connector.
When RTM-ATCA-7350 is configured with the GE daughter card, it provides two external Ethernet interfaces with 10/100/1000M Base-T auto-negotiation. Network cables are used to connect RTM-ATCA-7350 to the external network.
The figure below shows the method of connecting the network cables to RTM-ATCA-7350.
Figure 2-8 Connecting the Network Cables to RTM-ATCA-7350


Hardware Preparation and Installation Connecting Optical Fibers
When RTM-ATCA-7350 is configured with the FC daughter card, it provides two external 2G FC interfaces. Optical fibers are used to connect RTM-ATCA-7350 to the external Storage Area Network (SAN) storage system. Optical modules for the FC daughter cards must be obtained separately. Recommended modules are FINISAR FTRJ8519P1BNL-HW, FINISAR FTRJ8519P2BNL-HW.
As shown in steps 1 and 2 in the figure below, insert the optical module in the FC interface and then insert the optical fibers in the optical module.
Figure 2-9 Connecting the Optical Fibers to RTM-ATCA-7350


3.1 Overview
This chapter describes:
z Face plate connectors
z Face plate LEDs
z Rear panel connectors

Controls, LEDs and Connectors Face Plate Connectors and LEDs
The following figure shows the face plate of RTM-ATCA-7350 without daughter cards installed.
Figure 3-1 Face Plate of RTM-ATCA-7350

You need to install a filler blade in the position that is not occupied by the face plate of the daughter card.
The face plate of RTM-ATCA-7350 provides the following indicators:
z Out of service (OOS) indicator
z In service (IS) indicator
z Hotswap (H/S) indicator

LEDs Controls, LEDs and Connectors
The GE daughter card provides the network port indicators and the FC daughter card provides the FC status indicators. You can monitor these indicators to diagnose the current status of RTM-ATCA-7350.
The following table lists the indicators on the RTM-ATCA-7350 face plate.
Table 3-1 Indicators on the RTM-ATCA-7350 Face Plate
Indicator Color Meaning Description
OOS Red or amber Service status indicator
z The RTM-ATCA-7350 turns the red LED on when transitioning from FRU M3 to M4 state if in local control state. It is the responsibility of the application to change the status of the LED via IPMI command.
z The RTM-ATCA-7350 turns the LED off when transitioning from FRU state M6 to M1 if in local control state.
IS Red, green or amber
In service indicator The IS LED is off when the payload processor starts running.
Payload Management software is
responsible for controlling the IS LED.
H/S Blue Hot swap indicator z Off: RTM-ATCA-7350 is in activated state.
z On: RTM-ATCA-7350 is inserted, but in deactivated state or not powered on.
z Blinking at the long blink rate1: RTM-ATCA- 7350 is requesting activation.
z Blinking at the short blink rate2: RTM- ATCA-7350 is requesting deactivation.
ATN Amber Attention indicator The ATN LED is set to off when the payload processor starts running.
Payload Management software is responsible for controlling the ATN LED.

Controls, LEDs and Connectors Connectors
RTM-ATCA-7350 provides two daughter card connectors, as shown in the following figure.
Figure 3-2 Structure of RTM-ATCA-7350

In the above figure:
1 Daughter card connector J2
2 Daughter card connector J1
Face plate of the RTM-ATCA-7350 provides:
z One USB interface
z One VGA DB15 Port
Label Description

Connectors Controls, LEDs and Connectors
Figure 3-3 Connectors and Indicators of RTM-ATCA-7350


Controls, LEDs and Connectors Connectors
RTM-ATCA-7350 provides a single port USB connector on the face plate. The USB port is compliant to the USB 1.1 specification. The following USB Port Pin Assignment table describes the pinout information.
Figure 3-4 RTM-ATCA-7350 Front Plate USB Connector Pinout

Table 3-2 USB Port Pin Assignment
Pin Pin Name Description
1 +5V +5V Power Supply, Max 500mA each port.
2 Data- Differential Data transmitting pair.
4 GROUND Ground, connected to the logic GND of ATCA-7350.
ATCA-7350 provides its VGA output port through RTM-ATCA-7350. The VGA port on RTM- ATCA-7350 use a DB15 female connector with a signal definition compatible to the standard VGA plug.
Figure 3-5 RTM-ATCA-7350 Front Plate VGA Port Pinout

3 Data+

Zone 3 Connectors Controls, LEDs and Connectors
Table 3-3 VGA Port Pin Assignment
Pin Pin Name Description
1 RED Analog red video output signal.
2 GREEN Analog green video output signal.
3 BLUE Analog blue video output signal.
4 RESERVED1 Reserved.
5 RESERVED2 Reserved on RTM-ATCA-7350.
6 GROUND1 Connected to the logic ground of RTM-ATCA-7350.
7 GROUND2 Connected to the logic ground of RTM-ATCA-7350.
8 RESERVED3 Reserved on RTM-ATCA-7350.
9 RESERVED4 Reserved, Connected to 5VCC on RTM-ATCA-7350 through a PTC resistor.
10 GROUND3 Connected to the logic ground of RTM-ATCA-7350.
11 RESERVED5 Reserved.
12 DDC DATA DDC data pin for CRT.
13 HS Horizontal sync for Monitor.
14 VS Vertical sync for Monitor.
15 DDC CLK DDC pin SCL for CRT.
Zone 3 is composed of three connectors, P30, P31, and P32. The three connectors are used to connect RTMs with RTM-ATCA-7350s. Zone 3 defines the following signals:
z Power (VCC 12VDC, VSBY 5V5)
z General control signals (RTM PRESENT, RTM RST, LEDs)
z Fabric channel port 0, port 1, port 2, port 3 for the ATCA-7350
P30 uses a common 2mm HM connector. P31 uses a half-height ZD connector. P32 uses a ZD connector.
Refer to the PICMG specification for the location of the connectors.
The following table shows the P30 pinout. PinA1 on the server blade side is on the top of the connector while the server blade is placed top side upwards and the face plate is left.

Controls, LEDs and Connectors P31 Pinout
RTM_EN0_ and RTM_EN_ are signals that indicate the RTM is firmly inserted.
Table 3-4 PIN 30 Pinout
1 VSB5V RTM_EN0 GND RTM_OOSR_ RTM_HEALTHY_G _
2 VSB5V RTM_HOTSPWA P_
GND RTM_HEALTHY_ R
RTM_OOSY_
3 +12V RTM_TOP_EJEC TOR_
GND RTM_SDA RTM_SCL
4 +12V RT;_EPROM_WE GND VGA_RED CPLD_RTM_TDI
5 +12V RTM_BOT_EJEC TOR_
GND VGA_BLUE RTM_JTAG_TDO
6 +12V RTM_KBCLK GND VGA_GREEN CPLD_RTM_TCK
7 +12V RTM_MSDAT GND VGA_HS CPLD_RTM_TMS
8 +12V RTM_MSCLK GND VGA_VS CPLD_RTM_TRST
9 +12V RTM_KBDAT GND VGA_DDCCLK RTM_PWR_GOOD
10 +12V RTM_USB_P GND VGA_DDCDAT RTM_LM80_INT_
11 +12V RTM_USB_N GND RTM_SBY_RST RTM_EN_
3.3.2 P31 Pinout
P31 is used for port1 and port2 signals of the Fabric interface, and the PCIE signals from MCH.
PinA1 on the sever board side is on the top of the connector, and on the left column of the P31 connector while the server board is placed top side upwards and the front panel is on the left.
Table 3-5 PIN 31 Pinout
1 RTM_SYSLED _G_
RESERVED GND RTM_SYSLED _R_
RESERVED GND
2 RTM_FC2_TX 2_H RTM_FC2_TX2_ L
GND RTM_FC1_TX 2_H RTM_FC1_TX2_ L
GND
3 RTM_FC2_RX 2_H RTM_FC2_RX2_ L
GND RTM_FC1_RX 2_H RTM_FC1_RX2_ L
GND
4 RTM_FC2_TX 1_H RTM_FC2_TX1_ L
GND RTM_FC1_TX 1_H RTM_FC1_TX1_ L
GND
5 RTM_FC2_RX 1_H RTM_FC2_RX1_ L
GND RTM_FC1_RX 1_H RTM_FC1_RX1_ L
GND
6 RTM_PE7_PR SNT_R_
RTM_PE7_RST_ GND MCH_EXP7_R XP3
MCH_EXP7_RX N3
GND
7 RTM_EXP7_R XP3
RTM_EXP7_RXN 3 GND MCH_EXP7_R XP2
MCH_EXP7_RX N2
GND

P32 Pinout Controls, LEDs and Connectors
Table 3-5 PIN 31 Pinout (continued)
8 RTM_EXP7_R XP2
RTM_EXP7_RXN 2 GND MCH_EXP7_R XP1
MCH_EXP7_RX N1
GND
9 RTM_EXP7_R XP1
RTM_EXP7_RXN 1 GND MCH_EXP7_R XP0
MCH_EXP7_RX N0
GND
10 RTM_EXP7_R XP0
RTM_EXP7_RXN 0 GND RTM_PCIE7_ CLK_P
RTM_PCIE7_CL K_N
GND
3.3.3 P32 Pinout
P32 is used for port1 and port4 signals of the Fabric interface, and the PCIE signals from front board.
PinA1 on the server board side is on the top of the connector, and on the left column of the P32 connector while the server board is placed top side upwards and the front panel is on the left.
Table 3-6 PIN 32 Pinout
ZD2 A B C D E F G H
RTM_P E_SCL
GN D
MCH_E XP6_R XP1
MCH_E XP6_R XN1
GN D
RTM_E XP6_R XP3
RTM_E XP6_R XN3
GN D
MCH_E XP6_R XP3
MCH_E XP6_R XN3
GN D
2 RTM_E XP6_R XP1
RTM_E XP6_R XN1
GN D
MCH_E XP6_R XP0
MCH_E XP6_R XN0
GN D
RTM_E XP6_R XP2
RTM_E XP6_R XN2
GN D
MCH_E XP6_R XP2
MCH_E XP6_R XN2
GN D
3 RTM_E XP6_R XP0
RTM_E XP6_R XN0
GN D
RTM_P CIE6_C LK_P
RTM_P CIE6_C LK_N
GN D
RTM_E XP5_R XP3
RTM_E XP5_R XN3
GN D
MCH_E XP5_R XP3
MCH_E XP5_R XN3
GN D
4 RTM_E XP5_R XP1
RTM_E XP5_R XN1
GN D
MCH_E XP5_R XP1
MCH_E XP5_R XN1
GN D
RTM_E XP5_R XP2
RTM_E XP5_R XN2
GN D
MCH_E XP5_R XP2
MCH_E XP5_R XN2
GN D
5 RTM_E XP5_R XP0
RTM_E XP5_R XN0
GN D
MCH_E XP5_R XP0
MCH_E XP5_R XN0
GN D
RTM_P CIE4_C LK_P
RTM_P CIE4_C LK_N
GN D
RTM_P CIE5_C LK_P
RTM_P CIE5_C LK_N
GN D
6 RTM_E XP4_R XP1
RTM_E XP4_R XN1
GN D
MCH_E XP4_R XP1
MCH_E XP4_R XN1
GN D
RTM_E XP4_R XP3
RTM_E XP4_R XN3
GN D
MCH_E XP4_R XP3
MCH_E XP4_R XN3
GN D
7 RTM_E XP4_R XP0
RTM_E XP4_R XN0
GN D
MCH_E XP4_R XP0
MCH_E XP4_R XN0
GN D
RTM_E XP4_R XP2
RTM_E XP4_R XN2
GN D
MCH_E XP4_R XP2
MCH_E XP4_R XN2
GN D
8 RTM_P E6_PR SNT_R _
RTM_P E5_PR SNT_R _
GN D
RTM_P E4_PR SNT_
RTM_P E5_WA KE_
GN D
RTM_P E6_RS T_
RTM_P E5_RS T_
GN D
RTM_P E4_RS T_
RTM_P E4_WA KE_
GN D
9 RTM_F C2_TX3 _H
RTM_F C2_TX3 _L
GN D
RTM_F C1_TX3 _H
RTM_F C1_TX3 _L
GN D
RTM_F C2_TX0 _H
RTM_F C2_TX0 _L
GN D
RTM_F C1_TX0 _H
RTM_F C1_TX0 _L
GN D

Controls, LEDs and Connectors P32 Pinout
Table 3-6 PIN 32 Pinout (continued)
ZD2 A B C D E F G H
RTM_F C2_RX 3_L
GN D
RTM_F C1_RX 3_H
RTM_F C1_RX 3_L
GN D
RTM_F C2_RX 0_H
RTM_F C2_RX 0_L
GN D
RTM_F C1_RX 0_H
RTM_F C1_RX 0_L
GN D

4.1 Overview
This chapter describes:
The following block diagram shows the main components of RTM-ATCA-7350 and how they interact/are connected.
Figure 4-1 Block Diagram of RTM-ATCA-7350
LM80
USB
Port
VGA
VGA
Zone3(P30&P31&P32)
Port Power Supply
5VSBY & 12V & 3.3V
BCM57710 10GB/s PCI-EX4*2
P0,P1,P2,P3
Mezzanine 1 (Connector:J2)
Mezzanine 2 (Connector:J1)
4.3 Daughter Cards
RTM-ATCA-7350 provides two daughter card connectors, you can choose one or two GE daughter cards (single slot) or one FC daughter card (dual slot).

Functional Description GE Daughter Card
The GE daughter card provides two external Ethernet interfaces; 10/100/1000M Base-T auto- negotiation and RJ-45 interface. The RTM-ATCA-7350 can host one or two GE daughter cards, thus providing up to four external Ethernet interfaces.
The following figure shows the GE daughter card.
Figure 4-2 GE Daughter Card

The GE daughter card provides two network port indicators. You can monitor these indicators to diagnose the current status of the external Ethernet interfaces.
The following table lists the two network port indicators provided by the GE daughter card.
Table 4-1 Indicators Provided by the GE Daughter Card

z Green on: The network port is in Link state.
z Amber blinking: The network port is in Active state and is transmitting data.
The FC daughter card provides two 2G FC interfaces; FC-AL, FC-SW, point to point, and 1G/2G auto-negotiation. The RTM-ATCA-7350 can host one FC daughter card. Use of the FC daughter card excludes use of the GE daughter card.

FC Daughter Card Functional Description
Optical modules are used to provide the optical interfaces at the face plate. See Connecting Optical Fibers on page 36 for installing the optical modules. Optical modules for the FC daughter card must be obtained separately. Recommended modules are FINISAR FTRJ8519P1BNL-HW. FINISAR FTRJ8519P2BNL-HW.
The following figure shows the FC daughter card.
Figure 4-3 FC Daughter Card

The FC daughter card provides the RUN and ALM indicators. You can monitor these indicators to diagnose the current status of the external FC interfaces.
The following table lists the two indicators provided by the FC daughter card.
Table 4-2 Indicators Provided by the FC Daughter Card

z Green on and amber on: RTM-ATCA-7350 is in the power-on process.
z Green off and amber blinking: Signal synchronization is lost.
z Green off and amber on: The interfaces are obtaining signals.
z Green on and amber off: The interfaces are ready for processing signals.
z Green blinking and amber blinking: A fault occurs in the firmware.

Functional Description FC Daughter Card

A
A.1 Emerson Network Power - Embedded Computing Documents
The Emerson Network Power - Embedded Computing publications listed below are referenced in this manual. You can obtain electronic copies of Emerson Network Power - Embedded Computing publications by contacting your local Emerson sales office. For documentation of final released (GA) products, you can also visit the following website: http://www.emersonnetworkpowerembeddedcomputing.com > Resource Center > Technical Documentation Search. This site provides the most up-to-date copies of Emerson Network Power - Embedded Computing product documentation.
Table A-1 Emerson Network Power - Embedded Computing Publications
Document Title and Source Publication Number
ATCA-7350 Installation and Use 6806800G59
MESC-RTM-7150-FC Installation Information 6806800F90
MESC-RTM-7150-GE Installation Information 6806800F89
ATCA-7X50-HDDx-SAS/SATA Installation Information 6806800E28
ATCA-7x50-MEM Installation Information 6806800E27
ATCA-7350/RTM-ATCA-7350 Release Notes 6806800H69
For additional information, refer to the following table for related specifications. As an additional help, a source for the listed document is provided. Please note that, while these sources have been verified, the information is subject to change without notice.
Table A-2 Related Specifications
Platform Management FRU Information Storage Definition v1.0
developer.intel.com/design/servers/ipmi
IPMI Specification v1.5
PICMG 3.0 Revision 2.0 Advanced TCA Base Specification
Organization Document Title · Intel

Related Documentation Related Specifications