www.rosemount.com ¢00809-0300-4727h¤ Manual Supplemen t 00809-0300-4727, Rev AA June 2005 Rosemount 8700 Series Step 1: Disassembling the T ube and T ransmitter Step 2: Prep aring the Flo wtube Step.
Manual Supp lement 00809-0300-4727, Rev AA June 2005 Rosemount 8700 Series 2 © 2005 Rose mount Inc. All right s reserved. All ma rks property of owner . Introduction This document will explain how to change an integrally mounted Rosemount 87 32/8742 transmitter to a remote mount system.
Manual Supplemen t 00809-0300-4727, Rev AA June 2005 Rosemount 8700 Series 3 S TE P 1: D ISASSEMBLING THE T UBE AND T RA NSMITTER 1. Shut off the power going to the magnetic transmitter . 2. Remove the cover on the terminal strip side of the electronics housing.
Manual Supp lement 00809-0300-4727, Rev AA June 2005 Rosemount 8700 Series 4 S TE P 2: P REPARING THE F LOWTUBE 1. Remove the existing o-ring and discard appropriately . 2. Replace the o-ring with the new one sup p lied with the Remote Junction Box in the conversion kit.
Manual Supplemen t 00809-0300-4727, Rev AA June 2005 Rosemount 8700 Series 5 S TE P 3: P REPARING THE T RANSMIT TER 1. Position the remote mount terminal box adjac ent to the transmitter and carefully feed the wire leads so that they are accessible from the electronics access of the transmitter.
Manual Supp lement 00809-0300-4727, Rev AA June 2005 Rosemount 8700 Series 6 S TE P 4: W IRING THE T UBE AN D T RANSMITTER 1. Follow the procedures outlined in the m agnetic flow meter manual for making the proper wiring terminations between the T ransmitte r Remote T erminal box and the Flowtube T erminal Junction Box.
An important point after buying a device Emerson Process Management 8700 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson Process Management 8700 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson Process Management 8700 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson Process Management 8700 you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson Process Management 8700 will certainly help you make a decision on the purchase.
If you already are a holder of Emerson Process Management 8700, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson Process Management 8700.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson Process Management 8700. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson Process Management 8700 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center