EN
Emerson logo
Official user manual

Emerson MCD1200B

27 pages·989 KB·Air Cleaner·PDF·ENDEITNLJA
Emerson MCD1200B
Table of Contents 35 sections Language - Langue · Important Safety Instructions · Read and save these instructions · ATTENTION · … ShowHide
Page 1 of the Emerson MCD1200B user manual
Page 1 · click to enlarge
Page 1
Emerson MCD1200B diagram (page 1)
Fig. 1
Media Air Cleaner Épurateur d’air Média • MCS600W • MCS600B • MCD1200W • MCD1200B Electronic Air Cleaner Épurateur d’air Électronique • ECS750W • ECS750B • ECD1500W • ECD1500BOWNER’S MANUAL MANUEL OPÉRATEUR 2SD1 2SD2 Electrostatic Electric Air Cleaner Fan White-Rodgers is a division of Emerson Electric Co. www.white-rodgers.com
Emerson MCD1200B diagram (page 1)
Fig. 2
Emerson MCD1200B diagram (page 1)
Fig. 3
Emerson MCD1200B diagram (page 1)
Fig. 4
Page 2 of the Emerson MCD1200B user manual — Language - Langue
Page 2 · click to enlarge
Page 2

Language - Langue

English (USA/Canada)page 2
Français (Canada)page 13
Nomenclature Description Model NumberTypeCabinetAir FlowColor MCS600WMC = Media CleanerS = Single Cabinet600 = Maximum Air Flow (CFM)W = White MCS600BB = Bronze MCD1200WD = Double Cabinet1200 = Maximum Air Flow (CFM)W = White MCD1200BB = Bronze ECS750WEC = Electronic CleanerS = Single Cabinet750 = Maximum Air Flow (CFM)W = White ECS750BB = Bronze ECD1500WD = Double Cabinet1500 = Maximum Air Flow (CFM)W = White ECD1500BB = Bronze

0508082120/101203/C Page 1 Owner’s manual - Manuel opérateur

Page 3 of the Emerson MCD1200B user manual — Language - Langue
Page 3 · click to enlarge
Page 3
Page 3 of the Emerson MCD1200B user manual — Language - Langue
Page 4 of the Emerson MCD1200B user manual — WARNING
Page 4 · click to enlarge
Page 4

Important Safety Instructions

Read and save these instructions

ATTENTION

Mounting/installation Please follow the installation instructions carefully.

Please read instructions before installing and using the air cleaner. This will help you obtain the full benefit from the air cleaner you have selected.

Disconnect power prior to installing the air cleaner.

To reduce the risk of electric shock this equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet contact qualified personnel to install the proper outlet. Do not alter the plug in any way.

A Read the Owner’s Manual and Important Safety Instructions carefully. Failure to follow these instructions could cause a malfunction of the filter or unsatisfactory service. B Follow a regular service and maintenance schedule for efficient operation.

To reduce the risk of electric shock, fire and injury to persons:

Use common sense, stay vigilant and pay attention to your actions during installation. Do not install the air cleaner when tired or affected by drugs, alcohol, medicines or otherwise impaired.

  • Do not use the air cleaner in wet or damp locations.
  • The air cleaner is not for use in cooking areas.
  • Do not use the air cleaner with any solid state speed control device.
  • Do not use the air cleaner outdoors.
  • Do not use the air cleaner at ambient temperatures above 95°F/35°C.

Use only screws delivered in the installation kit. Using other screws may damage the air cleaner and can cause a risk of shock, fire or injury to persons.

Do not use excessive strength to fasten the screws of the mounting assembly accessories. It will damage the air cleaner or mounts causing the air cleaner to fall. Do not remove a wall mounted air cleaner once it is installed. Take special care when cleaning a wall mounted air cleaner. Only use the special mounting kit for recessed ceiling mounted air cleaners. Do not use the frame of the recessed ceiling to carry the weight of the air cleaner.

!

WARNING

ELECTROCUTION HAZARD.

Disconnect mains before servicing. Failure to do so could result in serious personal injury or death.

!

WARNING

Fire hazard Never use the air cleaner in areas with flammable gasses.

Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, utility connections and potential hazards. Installation should be performed only by a qualified service provider. Failure to do so could result in reduced performance of the unit, serious personal injury or death.

Never use the air cleaner to extract and/or filter flammable, smoldering or burning material.

Never use the air cleaner to extract and/or filter toxic fumes or abrasive particles. Do not place any objects on top of the air cleaner. Do not use with a damaged cord or plug.

!

CAUTION

CELLS MAY CONTAIN SHARP EDGES.

Do not pull the cord to remove the plug from the mains. Protect the cord against heat, oil and sharp objects. Do not run any appliance over the cord. To unplug, grasp the plug, not the cord. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not move the air cleaner without having it unplugged first.

Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury.

!

WARNING

Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to installation. Do not use this apparatus in a flammable or explosive atmosphere. Failure to do so could result in serious personal injury or death.

Page 5 of the Emerson MCD1200B user manual — 4.2 Cleaning the outside of the air cleaner
Page 5 · click to enlarge
Page 5

Operating Instructions 1 INTRODUCTION

  • For ceiling mounting of the air cleaners, use installation kit # F801 0195. For a single air cleaner one set is required, for the double air cleaner two sets are required.

This manual provides instructions for the mounting/installation, control and maintenance of the air cleaner. The safety instructions should be read first.

  • For recessed ceiling mounting of the single air cleaner use installation kit # F801 0196. For the double air cleaner, use installation kit # F801 0197.

2 PRODUCT DESCRIPTION

The air cleaner is provided with an Air Quality Analyzer. It measures the local pollution continuously and adjusts the fan speed accordingly. The analyzer is sensitive to pollution in gaseous form that occurs in, for example, tobacco smoke.

There are no components for mounting to the ceiling or wall in these kits.

Ensure that the load capacity of the mounting devices is sufficient to safely support the air cleaner. The weights of the air cleaner are maximum 39.9 lbs. and 65.5 lbs. respectively.

2.1 Filter package

See fig. 1 on page 25 The polluted air is cleaned in three successive stages.

For the single air cleaner on a pedestal, use pedestal installation kit # F848 0384.

2.1.1 Prefilter [A] The prefilter traps the coarser dust particles and other pollutants.

Use the materials prescribed during the installation. Connect the air cleaner to power only after complete installation.

2.1.2 Electronic filter [B] The electronic filter has a very high efficiency and traps dirt particles larger than 0.01 micron;

4 MAINTENANCE

or (in case of a media filter):

Maintain your air cleaner carefully and regularly. If poorly maintained, it can be a fire hazard. Always disconnect the air cleaner from power during maintenance and cleaning.

2.1.3 Media filter [B] The media filter is folded in such a way that it has a large effective surface area. This gives a low air resistance and a high dirt collection capacity.

Adhere to the maintenance instructions and advice on filter replacement. Replace or clean the filters on time.

2.1.4 Activated carbon filter [C] The activated carbon filter adsorbs unpleasant smells.

Only use manufacturer's original replacement parts.

2.2 Optional feature

Inspect the product for damages regularly. The safety features should be checked regularly for proper functioning and, if required, be repaired immediately. The cord should be checked regularly and, if damaged, replaced by a qualified service person.

2.2.1 Odor Free If the air cleaner is provided with an Odor Free filter obnoxious odors can be suppressed. The standard activated carbon filter is replaced by the Odor Free filter.

4.1 Filter replacement/cleaning frequency

3 MOUNTING/INSTALLATION

Filter replacement/cleaning frequency depends on local conditions, the fan speed selected and the operating time of the air cleaner. The Service Indicator can be used to help determine the filter replacement/cleaning frequency. See Program Settings step 1.

3.1 Technical specifications

SingleDouble Dimensions24.8x24.4x11.4 in.24.8x41.3x11.4 in. Max. built-in height8.3 in.8.3 in. Weightmax. 39.9 lbs.max. 65.5 lbs. Power consumption: - electronic - media130 W 118 W225 W 222 W Voltage115V, 60Hz115V, 60Hz

A crackling or snapping sound will be heard occasionally during use of the air cleaner. This is normal and is caused by high voltage arcing in the filter. Cleaning the electronic filter is necessary when the crackling or snapping is heard frequently.

Filter replacement/cleaning may be done as described in the technical repair section.

4.2 Cleaning the outside of the air cleaner

3.2 Air cleaner mounting/installation

Wipe the outside of the air cleaner with a moist cloth. Do not use cleaning products that contain ammonia or abrasives. The air cleaner is not resistant to organic solvents, such as benzene, etc. It is possible that the Air Quality Analyzer temporarily reacts abnormally with exposure to cleaning agents.

The air cleaner can be installed in several ways using different installation kits.

  • For wall mounting use installation kit # F801 0193. This kit is only suitable for single air cleaners.
Page 6 of the Emerson MCD1200B user manual — 5.3 Automatic operation ( AUTO mode)
Page 6 · click to enlarge
Page 6

5 CONTROL

6 PROGRAM SETTINGS

See fig. 5 on page 25 Do not close all vents simultaneously as this may result in the motor/fan overheating.

The air cleaner is shipped with factory default program settings. The following program settings allow you to customize the air cleaner operation for your personal preference.

The product is designed solely for cleaning air indoors and must not be used for any other purpose.

  • Program Setting 1: Service Indicator
  • Program Setting 2: Resetting the Service Indicator

The user is liable for damages resulting from improper use. Do not use the air cleaner when parts or safety devices are faulty, absent or damaged.

PROGRAM: press this button once to get in the program mode. While in the program mode if no key is pressed for 60 seconds the air cleaner will return to the last setting without saving any changes.

The air cleaner can be controlled in three different ways:

6.1 Program Setting 1: Service Indicator

A Using the panel button (>> button), for selecting fan speed or AUTO mode B Using the remote control C Using the Auto Clean mode (AUTO mode)

The Service Indicator is used to predict when the filter will need cleaning (electronic air cleaners) or replacement (media air cleaners).

5.1 Controlling with the panel button

  • The Service Indicator automatically calculates the service interval based on the pollution level selected and the fan speed. When the filter becomes clogged the leds
  • and
  • will flash each time the air cleaner is turned on.

See fig. 2 on page 25 The panel button (>> button) allows you to control the fan speed as follows:

Pollution level guidelines for establishing setting:

  • With the air cleaner OFF :
  • Press the panel button (>> ); control goes to AUTO .
  • Press the panel button (>> ); fan speed goes to
  • ( TURBO ).
  • Press the panel button (>> ); fan speed goes to
  • ( HIGH ).
  • Press the panel button (>> ); fan speed goes to
  • ( MEDIUM ).
  • Press the panel button (>> ); fan speed goes to
  • ( LOW ).
  • Press the panel button (>> ); fan speed goes to STANDBY .
  • Press the panel button (>> ); fan speed switches OFF .
  • LOW DUTY: general pollution without tobacco smoke
  • MEDIUM DUTY: moderate tobacco smoke concentrations
  • HEAVY DUTY: high tobacco smoke concentrations
  • EXTREME DUTY: extremely high tobacco smoke concentrations
  • To select the pollution level:
  • Press PROGRAM ; you are in the program mode 1 and STANDBY led will flash once every two seconds.
  • Default: OFF (all leds off).
  • Press V : led
  • ( LOW ) will light up, meaning you've set the pollution level to LOW DUTY.
  • Press V : led
  • ( MEDIUM ) will light up, meaning you have set the pollution level to MEDIUM DUTY.
  • Press V : led
  • ( HIGH ) will light up, meaning you have set the pollution level to HEAVY DUTY.
  • Press V : led
  • ( TURBO ) will light up, meaning you have set the pollution level to EXTREME DUTY.
  • If you want to go back to one of the previous pollution levels, press W .
  • Press PROGRAM to confirm setting 1 and to go to setting 2.

If you keep pressing on the panel button (>> ), the control will go one step every second.

5.2 Remote Control operation

See fig. 3 on page 25 Remote Control Fan Speed Indicators:

  • LOW
  • MEDIUM
  • HIGH
  • TURBO

6.2 Program Setting 2: Resetting the Service Indicator

  • OFF : switches off air cleaner.
  • V and W : fan speed goes one level higher ( V ) or lower ( W ).
  • AUTO : switches the air cleaner to automatic operation.
  • The indicator needs to be reset when the media filter is changed out. If led
  • and led
  • are flashing, it is time to change the filter(s) and to reset the indicator.

5.3 Automatic operation ( AUTO mode)

To Reset• Press PROGRAM : you are in the program mode 2 and the

See fig. 4 on page 25 Press AUTO on the remote control. There is a 5 minute warm up time for the Air Quality Analyzer. It is recommended the air cleaner be plugged in continuously to avoid the warm-up delay. If you activate AUTO during this time, the led on the control panel will flash. After 5 minutes you will hear a beep and the air cleaner will operate automatically.

  • STANDBY led will flash twice every two seconds.
  • Default: OFF (all leds are off).
  • If the indicator is programmed (setting 1), you will see all the leds switched on in setting 2, provided the Service Indicator is in use for a while.
  • Reset Service Indicator: press OFF (all leds are off).
  • Press PROGRAM : all user settings are saved and the air cleaner is back in normal control.
Page 7 of the Emerson MCD1200B user manual — 7 TROUBLESHOOTING
Page 7 · click to enlarge
Page 7

7 TROUBLESHOOTING

  • If leds
  • and
  • are flashing: This is the Service Indicator. It signifies time to service (replace or clean) the filter(s). Pressing any button will turn off the Service Indicator leds. When the unit is switched on again the Service Indicator will resume flashing. After changing the filter(s), the Service Indicator should be reset in Program Setting 2. Contact your service person.

If led AUTO is flashing: Air Quality Analyzer is warming up. After 5 minutes the Air Quality Analyzer is ready and air cleaner will start running in AUTO mode.

If led STANDBY is flashing: High Voltage Output problem in the collecting cell(s). If there is a dead short in the cell for over 60 seconds the STANDBY led flashes. Power will be interrupted to the cell(s) for 10 minutes which may allow the cause of the problem (e.g. hair) to flow out of the collecting cell. After 10 minutes the high voltage will return to the cell. If there is still a short in the cell the high voltage will again be interrupted for 10 minutes, etc. This loop stops at the fourth time a dead short condition is detected. Upon detection, the software blocks the fan control and the unit quits operating. The collecting cell should be cleaned to see if it can be returned to service or requires further repair. Contact your service person.

Page 8 of the Emerson MCD1200B user manual — 8 ADJUSTING TO SPECIFIC ROOM CONDITIONS
Page 8 · click to enlarge
Page 8

WARNING: RISK OF ELECTRIC SHOCK

These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

This guide contains service checks to assist service personnel in locating and correcting any condition that might occur to render the air cleaner ineffective or inoperative. The air cleaner has been designed with replaceable components, such as the high voltage power supply which allows the service person to simply replace a component rather than attempt repair of components in the field.

  • Program Setting 2: Resetting the Service Indicator The indicator needs to be reset when the media filter is changed out. If led
  • and led
  • are flashing, it is time to change the filter(s) and to reset the indicator.

To Reset:

  • Press PROGRAM : you are in the program mode 2 and the
  • STANDBY led will flash twice every two seconds.
  • Default: OFF (all leds are off).
  • If the indicator is programmed (setting 1), you will see all the leds switched on in setting 2, provided the Service Indicator is in use for a while.
  • Reset Service Indicator: press OFF (all leds are off).
  • Press PROGRAM : all user settings are saved and the air cleaner is back in normal control.

8 ADJUSTING TO SPECIFIC ROOM CONDITIONS

Program Setting 1: Service Indicator The Service Indicator is used to predict when the filter will need cleaning (electronic air cleaners) or replacement (media air cleaners).

  • Program Setting 3: Maximum fan speed for Air Quality Analyzer ( AUTO mode) It is not possible to go directly to setting 3. If the panel button (>> ) and then the PROGRAM key are pressed simultaneously before confirming setting 2, you're in setting 3 and STANDBY led will flash three times every two seconds. Adjusting the maximum fan speed for the Air Quality Analyzer is very convenient for meeting rooms and open plan offices.
  • Default:
  • ( TURBO ).
  • Press W and so on to go to the desired maximum fan speed.
  • Press PROGRAM : confirm setting 3 and go to setting 4.
  • The Service Indicator automatically calculates the service interval based on the pollution level selected and the fan speed. If the filter becomes clogged the led
  • and
  • will flash each time the air cleaner is turned on.

Pollution level guidelines for establishing setting:

  • LOW DUTY: general pollution without tobacco smoke
  • MEDIUM DUTY: moderate tobacco smoke concentrations
  • HEAVY DUTY: high tobacco smoke concentrations
  • EXTREME DUTY: extremely high tobacco smoke concentrations
  • Program Setting 4: Manual lock In setting 4 STANDBY led will flash four times every two seconds. Blocking the panel button (>> ), to ensure that non-authorised people cannot control the air cleaner.
  • Default: unlock; no leds are burning.
  • Press W or V : lock; led
  • ( LOW ) is burning.
  • Press W or V : unlock; led
  • ( LOW ) is off.
  • Press PROGRAM : confirm setting 4 and go to setting 5.
  • To select the pollution level:
  • Press PROGRAM ; you are in the program mode 1 and STANDBY led will flash once every two seconds.
  • Default: OFF (all leds off).
  • Press V : led
  • ( LOW ) will light up, meaning you've set the pollution level to LOW DUTY.
  • Press V : led
  • ( MEDIUM ) will light up, meaning you have set the pollution level to MEDIUM DUTY.
  • Press V : led
  • ( HIGH ) will light up, meaning you have set the pollution level to HEAVY DUTY.
  • Press V : led
  • ( TURBO ) will light up, meaning you have set the pollution level to EXTREME DUTY.
  • If you want to go back to one of the previous pollution levels, press W .
  • Press PROGRAM to confirm setting 1 and to go to setting 2.
  • Program Setting 5: Voltage output for maximum efficiency (Electronic Air Cleaners only) In setting 5 STANDBY led will flash five times every two seconds. This setting can be used to lower the efficiency (up to 10% at low HV). This will increase the time between cleaning intervals.
  • Default: high HV level (7600 V); leds
  • and
  • are burning.
Page 9 of the Emerson MCD1200B user manual — Cleaning the cell(s)
Page 9 · click to enlarge
Page 9
  • Press W : medium HV level (7300 V); leds
  • and
  • are burning.
  • Press W : low HV level (7100 V); led
  • is burning.
  • Press V : to increase efficiency again up to maximum HV level (7900 V); leds
  • and
  • are burning.
  • Press PROGRAM : confirm setting 5 and go to setting 6.

Reset to factory default To reset the factory default settings: Open the inlet grid, press the panel button (>> ). While pressing the panel button (>> ) close the inlet grid. Release the panel button (>> ) when you hear two beeps. Everything is now back into the default setting, except the Service Indicator (hours in use).

  • Program Setting 6: Maximum fan speed remote control/ panel button In setting 6 STANDBY led will flash six times every two seconds. Adjusting the maximum fan speed for remote control/panel button is very convenient for air cleaners installed in meeting rooms and open plan offices.
  • Default:
  • ( TURBO ).
  • Press W and so on to go to the desired maximum fan speed.
  • Press PROGRAM : confirm setting 6 and go to setting 7.

9 FILTER REPLACEMENT/CLEANING

See fig. 8 on page 25 In order to open the inlet grid (i.e. access the filter components), a narrow round screwdriver type tool will be needed (such as a torx type). The inlet grid is secured by two mechanical clips. To release these clips there are two access holes parallel to the control board faceplate on the inlet grid (approx. 3½" from the sides). Insert the tool into the access holes and gently push further through some light resistance. This will allow the clips to be "unlocked" and thus the inlet grid will open easily.

  • Program Setting 7: Sensitivity adjustment Air Quality Analyzer In setting 7 STANDBY led will flash seven times every two seconds. Setting the sensitivity of the Air Quality Analyzer. The more sensitive, the quicker the reaction to changes in pollution level.
  • Default: OFF (all leds are off), meaning the lowest sensitivity
  • Press V : led
  • ( LOW ) will light up, meaning you've set the pollution sensitivity to low.
  • press V : led
  • ( MEDIUM ) will light up, meaning you have set the pollution sensitivity to medium.
  • Press V : led
  • ( HIGH ) will light up, meaning you have set the pollution sensitivity to heavy.
  • Press V : led
  • ( TURBO ) will light up, meaning you have set the pollution sensitivity to extreme.
  • If you want to go back to one of the previous pollution sensitivity, press W .
  • Press PROGRAM to confirm setting 7 and go to setting 8.

DO NOT PULL THE DOOR OPEN WITHOUT RELEASING THE CLIPS.

9.1 Prefilter replacement

The disposable prefilter can only be used once and cannot be cleaned. Do not turn the prefilter around since it can only be used in one flow direction.

9.2 Electronic filter cleaning

A crackling or snapping sound will be heard occasionally during use of the air cleaner. This is normal and is caused by high voltage arcing in the filter. Cleaning the electronic filter is necessary when the crackling is heard frequently.

!

CAUTION

  • Program Setting 8: Time without high voltage after Service (Electronic Air Cleaners only) In setting 8 STANDBY led will flash eight times every two seconds. Setting a specific time for no high voltage after servicing is useful when the filter cells are damp or condensed in winter time. This setting will go back to default value if power is interrupted to the air cleaner.
  • Default: OFF (all leds are off), when the air cleaner is switched on, there's always high voltage on the cell(s).
  • Press V : led
  • ( LOW ) will light up, meaning you've set the time of no high voltage to 30 minutes.
  • Press V : led
  • ( MEDIUM ) will light up, meaning you've set the time of no high voltage to 60 minutes.
  • Press V : led
  • ( HIGH ) will light up, meaning you've set the time of no high voltage to 120 minutes.
  • Press V : led
  • ( TURBO ) will light up, meaning you've set the time of no high voltage to 240 minutes.
  • If you want to go back to one of the previous time setting levels, press W .
  • Press PROGRAM to confirm setting 8. The air cleaner will return to the normal running mode.

CELLS MAY CONTAIN SHARP EDGES.

Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury.

For maximum efficiency your air cleaner cell(s) should be cleaned regularly. When cleaning is required the following procedure should be used:

Cleaning the cell(s)

A Turn the air moving system OFF and disconnect the air cleaner from power. Wait 15 seconds for the collecting cell(s) to discharge.

B Remove the cell(s) and prefilter(s) from cabinet. Using a solution of warm water and low sudsing detergent, soak cell(s) for 20 to 30 minutes. Discard prefilter(s) and carbon filter(s). NOTE: Ionizing wires may become coated causing loss of cleaning ability by the collecting cell. Using a damp cloth, wipe each ionizing wire, exercising care not to damage them.

Page 10 of the Emerson MCD1200B user manual — 9.4 Activated carbon or Odor Free filter replacement
Page 10 · click to enlarge
Page 10

C Remove the cell(s) from the solution and rinse thoroughly with clean hot water water.

D Allow cell(s) to drip dry for a minimum of 2 hours. Cell(s) may be tipped at a slight angle to expedite the drip-dry process.

E Reinstall the cell(s) and new replacement prefilter(s) and carbon filter(s) in the cabinet.

A moderate amount of arcing or "snapping" may occur when the unit is turned on. This may indicate that the cell(s) are still damp. Turn the unit off and allow it more drying time or go to Program Setting 8.

9.3 Media filter replacement

The disposable media filter can only be used once and cannot be cleaned. Replace as necessary.

9.4 Activated carbon or Odor Free filter replacement

The disposable activated carbon or the Odor Free filters can only be used once and cannot be cleaned. They are located behind the electronic/media filter. Replace as necessary.

Page 11 of the Emerson MCD1200B user manual — 10 BASIC SERVICE GUIDE
Page 11 · click to enlarge
Page 11

10 BASIC SERVICE GUIDE

The Basic Service Guide should cover most performance issues. If after checking the items listed, the air cleaner still fails to operate properly please contact your distributor.

ConditionPossible causeSolution Air cleaner inoperable.Malfunctioning safety switch.Properly close the extraction grid or contact your service person. Disconnected from power.Reconnect power. Faulty cord or plug.Distributor to replace the cord or plug. Faulty hardware and/or software.Contact your distributor for replacement parts. Poorly operating or malfunctioning remote control.(Nearly) exhausted battery.Check the red led above the • button on the remote control by pressing any button. Replace the battery if the led is not activated. Fan fails to rotate.Defective fan.Contact your distributor for replacement parts. Faulty hardware and/or software.Contact your distributor for replacement parts. Fan works but the air cleaner functions poorly or not at all.One or more filters are polluted.Replace or clean the filters. Vents are closed.Open one or more of the vents (see section 5). Dirt in the electronic filter causes a short-circuit (STANDBY led blinks)Clean the electronic filter. Crackling sound from the electronic filter.Electronic filter dirty or wet.Clean or dry the electronic filter. Missing prefilter.Install prefilter. The air cleaner cannot be controlled manually.Control is locked out.See Program Setting # 4 (page 7) to unlock. STANDBY led blinks.Dirt in the electronic filter causes a short-circuit.Clean the electronic filter. Short-circuit in the electronic filter by a broken ionizing wire and/or bent collector plates.Contact your distributor. Air cleaner is in PROGRAM mode.Push the PROGRAM button on the remote control once or several times to scroll through the menu or wait for 1 minute. and • leds blink.The Service Indicator indicates that the filters are clogged.Clean the electronic filter or replace the media filter. The fan speed does not increase when using the Air Quality Analyzer.Fan speed limited.See Program Setting # 6 (page 8) to change maximum fan speed. The Air Quality Analyzer starts while the atmosphere is apparently clean.Sensor reacts to, for instance, high or low humidity or fumes from cleaning agents.The sensitivity will adjust itself after some time. Air Quality Analyzer is too sensitive.Contact your distributor. Smells are no longer adsorbed.Activated carbon filter or Odor Free filter is saturated.Replace the activated carbon filter or Odor Free filter.
Page 12 of the Emerson MCD1200B user manual — Parts List
Page 12 · click to enlarge
Page 12

Parts List

Pos.WhiteRodgers P/NDescriptionULUnits where usedPrice € MCS600WMCS600BMCD1200WMCD1200BECS750WECS750BECD1500WECD1500B Electrical components 1F849 0064Motor + fan (120V/1ph/60Hz)xxxxxxxxx96,00 2F809 0095Capacitor 5,0 µF (120V/1ph/60Hz)xxxxxxxxx1,40 3F859 0386PC board controlxxxxxxxxx72,00 4F859 0387PC board HTxxxxx40,40 5F881 0241HT transformer (120V/1ph/60Hz)xxxxx65,60 7F881 0242Transformer motor (120V/1ph/60Hz)xxxxxxxxx30,60 8F881 0244Choke 120V/60Hz Kit UV Lightxxxxxxxxx25,00 10F829 0014Fuse 4,0 A-T (120V/60Hz)xxxxxxxxx1,44 11F848 0389Sensor module Air Quality Analyzerxxxxxxxxx80,40 12F843 1398Ionizing wires collecting cell (set of 10)xxxxx15,88 13F848 0390Remote controlxxxxxxxxx15,64 14F819 0160Contact boardxxxxx6,20 15F843 1399Flatcablexxxxx1,24 Mechanical components 16F831 0131Inlet grid whitexxxxxxxxx28,84 17F831 0132Inlet grid bronzexxxxxxxxx44,00 18F828 0212Frame prefilterxxxxxxxxx2,48 19F833 0023Hinge inlet gridxxxxxxxxx0,84 20F820 0355Base cover whitexxx7,50 21F820 0356Base cover bronzexxx11,80 22F839 0020Turning knob electronic cellxxxxx0,60 23F828 0213Fan protection framexxxxxxxxx2,48 24F820 0357Cover fragrance gelxxxxxxxxx0,40 25F828 0214Frame activated carbon filter (set of 10)xxxxxxxxx24,72 Spare filters 26aF825 0630Prefilter (72 pcs)xxxxxxxxx75,60 26bF825 0631Prefilter (600 pcs)xxxxxxxxx540,00 27aF825 0632Media filter (2 pcs)xxxxx42,00 27bF825 0633Media filter (40 pcs)xxxxx800,00 28F825 0634Electronic cellxxxxx84,40 29aF825 0635Activated carbon filter (72 pcs)xxxxxxxxx205,20 29bF825 0636Activated carbon filter (625 pcs)xxxxxxxxx1.625,00 30aF825 0628Activated carbon filter Odor Free (option, 2 pcs)xxxxxxxxx47,40 30bF825 0629Activated carbon filter Odor Free (option, 48 pcs)xxxxxxxxx1.056,00 32F848 0391Fragrance gel (72 pcs)xxxxxxxx165,60 F801 0198Level 1 Service Kit includes: 6 Pre-filters, 1 media filter, 6 activated carbon filtersxxxx71,50 F801 0199Level 2 Service Kit includes: 12 Pre-filters, 2 media filters, 12 activated carbon filtersxxxx114,25 F801 0200Level 3 Service Kit includes: 18 Pre-filters, 3 media filters, 18 activated carbon filtersxxxx157,50 F801 0201Level 4 Service Kit includes: 24 Pre-filters, 4 media filters, 24 activated carbon filtersxxxx200,50 F801 0202Service Kit for Electronic Air Cleaners includes: 12 Pre-filters, 12 activated carbon filtersxxxx75,00 General components 33F848 0386Service tool for ionizing wires electronic cellxxxx12,36 34F810 0360Service transport box electronic cellxxxx20,30 F801 0194Corner Wall Mount Hardware Kitxxxx F801 0193Wall mounting kit for single air cleaner (option)xxxx5,20 F801 0196Recessed ceiling mount kit for single air cleanerxxxx11,00 F801 0197Recessed ceiling mount kit for double air cleanerxxxx16,00 F848 0384Pedestal mount for single air cleaner (option)xxxx64,00 F801 0195Ceiling mount kitxxxxxxxx5,20

Parts List

Page 13 of the Emerson MCD1200B user manual — Parts List
Page 13 · click to enlarge
Page 13

Parts List

Emerson MCD1200B — Parts List diagram (page 13)
Fig. 5 · Parts List
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Air cleaner inoperable.Malfunctioning safety switch.Properly close the extraction grid or contact your service person. p.11
Air cleaner inoperable.Disconnected from power.Reconnect power. p.11
Air cleaner inoperable.Faulty cord or plug.Distributor to replace the cord or plug. p.11
Air cleaner inoperable.Faulty hardware and/or software.Contact your distributor for replacement parts. p.11
Poorly operating or malfunctioning remote control.(Nearly) exhausted battery.Check the red led above the • button on the remote control by pressing any button. Replace the battery if the led is not activated. p.11
Fan fails to rotate.Defective fan.Contact your distributor for replacement parts. p.11
Fan fails to rotate.Faulty hardware and/or software.Contact your distributor for replacement parts. p.11
Fan works but the air cleaner functions poorly or not at all.One or more filters are polluted.Replace or clean the filters. p.11
Fan works but the air cleaner functions poorly or not at all.Vents are closed.Open one or more of the vents (see section 5). p.11
Fan works but the air cleaner functions poorly or not at all.Dirt in the electronic filter causes a short-circuit (STANDBY led blinks)Clean the electronic filter. p.11
Crackling sound from the electronic filter.Electronic filter dirty or wet.Clean or dry the electronic filter. p.11
Crackling sound from the electronic filter.Missing prefilter.Install prefilter. p.11
The air cleaner cannot be controlled manually.Control is locked out.See Program Setting # 4 (page 7) to unlock. p.11
STANDBY led blinks.Dirt in the electronic filter causes a short-circuit.Clean the electronic filter. p.11
STANDBY led blinks.Short-circuit in the electronic filter by a broken ionizing wire and/or bent collector plates.Contact your distributor. p.11
STANDBY led blinks.Air cleaner is in PROGRAM mode.Push the PROGRAM button on the remote control once or several times to scroll through the menu or wait for 1 minute. p.11
•••• and • leds blink.The Service Indicator indicates that the filters are clogged.Clean the electronic filter or replace the media filter. p.11
The fan speed does not increase when using the Air Quality Analyzer.Fan speed limited.See Program Setting # 6 (page 8) to change maximum fan speed. p.11
The Air Quality Analyzer starts while the atmosphere is apparently clean.Sensor reacts to, for instance, high or low humidity or fumes from cleaning agents.The sensitivity will adjust itself after some time. p.11
The Air Quality Analyzer starts while the atmosphere is apparently clean.Air Quality Analyzer is too sensitive.Contact your distributor. p.11
Smells are no longer adsorbed.Activated carbon filter or Odor Free filter is saturated.Replace the activated carbon filter or Odor Free filter. p.11

Ask about the Emerson MCD1200B

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson MCD1200B

Be the first to ask — other owners or our team will answer.

Original document

Emerson MCD1200B manual PDF

27 pages·989 KB·Air Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…