Part No. SP6551 Printed in Canada CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. SAVE THIS OWNER’S MANUAL FOR FUTURE REFERENCE. Model No.
Safety Signal W ords DANGER: means if the safety information is not followed someone will be seriously injured or killed. WARNING: means if the safety information is not followed someone could be seriously injured or killed. CAUTION: means if the safety information is not followed someone may be injured.
3 Know Y our Humidifier Controls Humidity Light Fill Light Bottles Fan Assembly Filters: Replacement No. HDC-12 or HDC12C Control Panel Cover & Pivoting Lid Removed for Clarity Filter Housing Description HD1405 Gallon Output/24 hrs.* 14 Litre Output / 24 hrs.
Humidifier Operations Your new Emerson humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air. After water is added to the bottles and posi- tioned in the humidifier, the filters begin to soak up the water and become totally saturat- ed in approximately 30 minutes.
5 WARNING : For your own safety, do not use humidifier if any parts are damaged or missing. Step 1 Place humidifier on a flat level surface in area of house where humidity is needed most, or one which would likely result in moist air being circulated throughout the house such as near a cold air return.
W ater Fill (continued) Open the pivoting lid of the humidifier. Remove the water bottles, by lifting them straight up and out of the cabinet. Notice the water bottles are designed as right and left hand units. Position them in the cor- rect location so the humidifier can function properly.
7 Operating Humidifier Controls The operating controls of your Emerson evaporative humidifier are located on the top center of the humidifier. The controls are found under the smoked cover, located between the air circulating fans. Lift the con- trol cover by placing your finger in the round cutout and lifting.
Using Y our Humidifier Step 1 Be sure unit is full of water and plugged in. Step 2 Set air flow control to desired setting. Step 3 Set Humidity Control to medium position (half way between and ) NOTE: Humidifier should operate with humid- ity control on the recommended medium set- ting.
9 Replacement and Care of Filters WARNING: To reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or replacing any parts. CAUTION: To help retard bacteria growth and keep maximum efficiency, the filters should be replaced at least once a season, or more often under hard water conditions.
10 Replacement and Care of Filters (continued) c. Install new filters in the filter housing track with the glue beads of the wicking pad to the inside of the filter housing.
11 Cleaning Y our Humidifier CAUTION: To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, com- bustible or poisonous materials to clean your humidifier. To reduce the risk of scalds and damage to humidifier, never put hot water in humidifier.
12 Bi-Weekly Maintenance Removing Scale 1. Fill the humidifier cabinet with one 8 oz. cup of undiluted white vinegar. Let solu- tion stay 20 minutes. 2. Clean all interior surfaces with soft brush. Dampen a soft cloth with undiluted white vinegar and wipe out the humidifier cabi- net to remove scale.
13 T roubleshooting CAUTION: Use only approved EPA Registered liquid bacteriostat available from your local retail store. Use of other water treatment products may damage the filter elements. Under no circumstances should you use water treatment products designed for Rotobelt or Ultrasonic humidifiers.
14 Repair Parts Parts List for MoistAir Humidifier Model No. HD14050 28 27 26 25 24 23 28 27 21 26 30 24 23 22 21 20 19 18 14 15 13 31 12 11 33 16 17 3 1 32 8 10 7 5 4 6 9 34 2 SP6551 manual - 71238 7.
15 Repair Parts Parts List for MoistAir Humidifier Model No. HD14050 Always order by part number - Not by key number Key Part No. Description No. 1 823884 Cover, Dust 2 829844 Lid, Stationary 3 829841.
© 2004 Emerson Part No. SP6551 Form No. SP6551 Printed in Canada 11/04 FOR TECHNICAL HELP, CALL (800) 654-3545 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) Emerson Tool Company For more information about MoistAir® humidifiers visit our website at www.
An important point after buying a device Emerson HD1405 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson HD1405 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson HD1405 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson HD1405 you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson HD1405 will certainly help you make a decision on the purchase.
If you already are a holder of Emerson HD1405, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson HD1405.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson HD1405. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson HD1405 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center