Mounting/installation Please follow the installation instructions carefully.
Please read instructions before installing and using the air cleaner. This will help you obtain the full benefit from the air cleaner you have selected.
Disconnect power prior to installing the air cleaner.
To reduce the risk of electric shock this equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet contact qualified personnel to install the proper outlet. Do not alter the plug in any way.
A Read the Owner’s Manual and Important Safety Instructions carefully. Failure to follow these instructions could cause a malfunction of the filter or unsatisfactory service. B Follow a regular service and maintenance schedule for efficient operation.
To reduce the risk of electric shock, fire and injury to persons:
Use common sense, stay vigilant and pay attention to your actions during installation. Do not install the air cleaner when tired or affected by drugs, alcohol, medicines or otherwise impaired.
Use only screws delivered in the installation kit. Using other screws may damage the air cleaner and can cause a risk of shock, fire or injury to persons.
Do not use excessive strength to fasten the screws of the mounting assembly accessories. It will damage the air cleaner or mounts causing the air cleaner to fall. Do not remove a wall mounted air cleaner once it is installed. Take special care when cleaning a wall mounted air cleaner. Only use the special mounting kit for recessed ceiling mounted air cleaners. Do not use the frame of the recessed ceiling to carry the weight of the air cleaner.
ELECTROCUTION HAZARD.
Disconnect mains before servicing. Failure to do so could result in serious personal injury or death.
Fire hazard Never use the air cleaner in areas with flammable gasses.
Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, utility connections and potential hazards. Installation should be performed only by a qualified service provider. Failure to do so could result in reduced performance of the unit, serious personal injury or death.
Never use the air cleaner to extract and/or filter flammable, smoldering or burning material.
Never use the air cleaner to extract and/or filter toxic fumes or abrasive particles. Do not place any objects on top of the air cleaner. Do not use with a damaged cord or plug.
CELLS MAY CONTAIN SHARP EDGES.
Do not pull the cord to remove the plug from the mains. Protect the cord against heat, oil and sharp objects. Do not run any appliance over the cord. To unplug, grasp the plug, not the cord. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not move the air cleaner without having it unplugged first.
Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury.
Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to installation. Do not use this apparatus in a flammable or explosive atmosphere. Failure to do so could result in serious personal injury or death.

This manual provides instructions for the mounting/installation, control and maintenance of the air cleaner. The safety instructions should be read first.
The air cleaner is provided with an Air Quality Analyzer. It measures the local pollution continuously and adjusts the fan speed accordingly. The analyzer is sensitive to pollution in gaseous form that occurs in, for example, tobacco smoke.
There are no components for mounting to the ceiling or wall in these kits.
Ensure that the load capacity of the mounting devices is sufficient to safely support the air cleaner. The weights of the air cleaner are maximum 39.9 lbs. and 65.5 lbs. respectively.
See fig. 1 on page 25 The polluted air is cleaned in three successive stages.
For the single air cleaner on a pedestal, use pedestal installation kit # F848 0384.
2.1.1 Prefilter [A] The prefilter traps the coarser dust particles and other pollutants.
Use the materials prescribed during the installation. Connect the air cleaner to power only after complete installation.
2.1.2 Electronic filter [B] The electronic filter has a very high efficiency and traps dirt particles larger than 0.01 micron;
or (in case of a media filter):
Maintain your air cleaner carefully and regularly. If poorly maintained, it can be a fire hazard. Always disconnect the air cleaner from power during maintenance and cleaning.
2.1.3 Media filter [B] The media filter is folded in such a way that it has a large effective surface area. This gives a low air resistance and a high dirt collection capacity.
Adhere to the maintenance instructions and advice on filter replacement. Replace or clean the filters on time.
2.1.4 Activated carbon filter [C] The activated carbon filter adsorbs unpleasant smells.
Only use manufacturer's original replacement parts.
Inspect the product for damages regularly. The safety features should be checked regularly for proper functioning and, if required, be repaired immediately. The cord should be checked regularly and, if damaged, replaced by a qualified service person.
2.2.1 Odor Free If the air cleaner is provided with an Odor Free filter obnoxious odors can be suppressed. The standard activated carbon filter is replaced by the Odor Free filter.
3 MOUNTING/INSTALLATION
Filter replacement/cleaning frequency depends on local conditions, the fan speed selected and the operating time of the air cleaner. The Service Indicator can be used to help determine the filter replacement/cleaning frequency. See Program Settings step 1.
A crackling or snapping sound will be heard occasionally during use of the air cleaner. This is normal and is caused by high voltage arcing in the filter. Cleaning the electronic filter is necessary when the crackling or snapping is heard frequently.
Filter replacement/cleaning may be done as described in the technical repair section.
3.2 Air cleaner mounting/installation
Wipe the outside of the air cleaner with a moist cloth. Do not use cleaning products that contain ammonia or abrasives. The air cleaner is not resistant to organic solvents, such as benzene, etc. It is possible that the Air Quality Analyzer temporarily reacts abnormally with exposure to cleaning agents.
The air cleaner can be installed in several ways using different installation kits.

6 PROGRAM SETTINGS
See fig. 5 on page 25 Do not close all vents simultaneously as this may result in the motor/fan overheating.
The air cleaner is shipped with factory default program settings. The following program settings allow you to customize the air cleaner operation for your personal preference.
The product is designed solely for cleaning air indoors and must not be used for any other purpose.
The user is liable for damages resulting from improper use. Do not use the air cleaner when parts or safety devices are faulty, absent or damaged.
PROGRAM: press this button once to get in the program mode. While in the program mode if no key is pressed for 60 seconds the air cleaner will return to the last setting without saving any changes.
The air cleaner can be controlled in three different ways:
A Using the panel button (>> button), for selecting fan speed or AUTO mode B Using the remote control C Using the Auto Clean mode (AUTO mode)
The Service Indicator is used to predict when the filter will need cleaning (electronic air cleaners) or replacement (media air cleaners).
See fig. 2 on page 25 The panel button (>> button) allows you to control the fan speed as follows:
Pollution level guidelines for establishing setting:
If you keep pressing on the panel button (>> ), the control will go one step every second.
See fig. 3 on page 25 Remote Control Fan Speed Indicators:
See fig. 4 on page 25 Press AUTO on the remote control. There is a 5 minute warm up time for the Air Quality Analyzer. It is recommended the air cleaner be plugged in continuously to avoid the warm-up delay. If you activate AUTO during this time, the led on the control panel will flash. After 5 minutes you will hear a beep and the air cleaner will operate automatically.

If led AUTO is flashing: Air Quality Analyzer is warming up. After 5 minutes the Air Quality Analyzer is ready and air cleaner will start running in AUTO mode.
If led STANDBY is flashing: High Voltage Output problem in the collecting cell(s). If there is a dead short in the cell for over 60 seconds the STANDBY led flashes. Power will be interrupted to the cell(s) for 10 minutes which may allow the cause of the problem (e.g. hair) to flow out of the collecting cell. After 10 minutes the high voltage will return to the cell. If there is still a short in the cell the high voltage will again be interrupted for 10 minutes, etc. This loop stops at the fourth time a dead short condition is detected. Upon detection, the software blocks the fan control and the unit quits operating. The collecting cell should be cleaned to see if it can be returned to service or requires further repair. Contact your service person.

These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
This guide contains service checks to assist service personnel in locating and correcting any condition that might occur to render the air cleaner ineffective or inoperative. The air cleaner has been designed with replaceable components, such as the high voltage power supply which allows the service person to simply replace a component rather than attempt repair of components in the field.
To Reset:
Program Setting 1: Service Indicator The Service Indicator is used to predict when the filter will need cleaning (electronic air cleaners) or replacement (media air cleaners).
Pollution level guidelines for establishing setting:

Reset to factory default To reset the factory default settings: Open the inlet grid, press the panel button (>> ). While pressing the panel button (>> ) close the inlet grid. Release the panel button (>> ) when you hear two beeps. Everything is now back into the default setting, except the Service Indicator (hours in use).
See fig. 8 on page 25 In order to open the inlet grid (i.e. access the filter components), a narrow round screwdriver type tool will be needed (such as a torx type). The inlet grid is secured by two mechanical clips. To release these clips there are two access holes parallel to the control board faceplate on the inlet grid (approx. 3½" from the sides). Insert the tool into the access holes and gently push further through some light resistance. This will allow the clips to be "unlocked" and thus the inlet grid will open easily.
DO NOT PULL THE DOOR OPEN WITHOUT RELEASING THE CLIPS.
The disposable prefilter can only be used once and cannot be cleaned. Do not turn the prefilter around since it can only be used in one flow direction.
A crackling or snapping sound will be heard occasionally during use of the air cleaner. This is normal and is caused by high voltage arcing in the filter. Cleaning the electronic filter is necessary when the crackling is heard frequently.
CELLS MAY CONTAIN SHARP EDGES.
Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury.
For maximum efficiency your air cleaner cell(s) should be cleaned regularly. When cleaning is required the following procedure should be used:
A Turn the air moving system OFF and disconnect the air cleaner from power. Wait 15 seconds for the collecting cell(s) to discharge.
B Remove the cell(s) and prefilter(s) from cabinet. Using a solution of warm water and low sudsing detergent, soak cell(s) for 20 to 30 minutes. Discard prefilter(s) and carbon filter(s). NOTE: Ionizing wires may become coated causing loss of cleaning ability by the collecting cell. Using a damp cloth, wipe each ionizing wire, exercising care not to damage them.

C Remove the cell(s) from the solution and rinse thoroughly with clean hot water water.
D Allow cell(s) to drip dry for a minimum of 2 hours. Cell(s) may be tipped at a slight angle to expedite the drip-dry process.
E Reinstall the cell(s) and new replacement prefilter(s) and carbon filter(s) in the cabinet.
A moderate amount of arcing or "snapping" may occur when the unit is turned on. This may indicate that the cell(s) are still damp. Turn the unit off and allow it more drying time or go to Program Setting 8.
The disposable media filter can only be used once and cannot be cleaned. Replace as necessary.
The disposable activated carbon or the Odor Free filters can only be used once and cannot be cleaned. They are located behind the electronic/media filter. Replace as necessary.

The Basic Service Guide should cover most performance issues. If after checking the items listed, the air cleaner still fails to operate properly please contact your distributor.

Parts List



Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Air cleaner inoperable. | Malfunctioning safety switch. | Properly close the extraction grid or contact your service person. | p.11 |
| Air cleaner inoperable. | Disconnected from power. | Reconnect power. | p.11 |
| Air cleaner inoperable. | Faulty cord or plug. | Distributor to replace the cord or plug. | p.11 |
| Air cleaner inoperable. | Faulty hardware and/or software. | Contact your distributor for replacement parts. | p.11 |
| Poorly operating or malfunctioning remote control. | (Nearly) exhausted battery. | Check the red led above the • button on the remote control by pressing any button. Replace the battery if the led is not activated. | p.11 |
| Fan fails to rotate. | Defective fan. | Contact your distributor for replacement parts. | p.11 |
| Fan fails to rotate. | Faulty hardware and/or software. | Contact your distributor for replacement parts. | p.11 |
| Fan works but the air cleaner functions poorly or not at all. | One or more filters are polluted. | Replace or clean the filters. | p.11 |
| Fan works but the air cleaner functions poorly or not at all. | Vents are closed. | Open one or more of the vents (see section 5). | p.11 |
| Fan works but the air cleaner functions poorly or not at all. | Dirt in the electronic filter causes a short-circuit (STANDBY led blinks) | Clean the electronic filter. | p.11 |
| Crackling sound from the electronic filter. | Electronic filter dirty or wet. | Clean or dry the electronic filter. | p.11 |
| Crackling sound from the electronic filter. | Missing prefilter. | Install prefilter. | p.11 |
| The air cleaner cannot be controlled manually. | Control is locked out. | See Program Setting # 4 (page 7) to unlock. | p.11 |
| STANDBY led blinks. | Dirt in the electronic filter causes a short-circuit. | Clean the electronic filter. | p.11 |
| STANDBY led blinks. | Short-circuit in the electronic filter by a broken ionizing wire and/or bent collector plates. | Contact your distributor. | p.11 |
| STANDBY led blinks. | Air cleaner is in PROGRAM mode. | Push the PROGRAM button on the remote control once or several times to scroll through the menu or wait for 1 minute. | p.11 |
| •••• and • leds blink. | The Service Indicator indicates that the filters are clogged. | Clean the electronic filter or replace the media filter. | p.11 |
| The fan speed does not increase when using the Air Quality Analyzer. | Fan speed limited. | See Program Setting # 6 (page 8) to change maximum fan speed. | p.11 |
| The Air Quality Analyzer starts while the atmosphere is apparently clean. | Sensor reacts to, for instance, high or low humidity or fumes from cleaning agents. | The sensitivity will adjust itself after some time. | p.11 |
| The Air Quality Analyzer starts while the atmosphere is apparently clean. | Air Quality Analyzer is too sensitive. | Contact your distributor. | p.11 |
| Smells are no longer adsorbed. | Activated carbon filter or Odor Free filter is saturated. | Replace the activated carbon filter or Odor Free filter. | p.11 |