Instruction/ maintenance manual of the product CF905BS00 Emerson
Go to page of 16
Part No. F40BP74320000 Form No. BP7432 U.L. Model No.: CF905 READ AND SA VE THESE INSTRUCTIONS Ceiling F an Owner's Manual CF905BS00 CF905CK00 CF905GES00 Model Number s PRIMA SNUGGER Net W eight: 18.
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
3 U.L. Model No.: CF905 EMERSON QUICK ST ART GUIDE The Quick Start Guide covers the installation instructions common for ceiling fan operations. If additional assistance with wiring, alternate hanging systems, or lighting options, proceed to the complete instructions of this Owner’s Manual.
4 U.L. Model No.: CF905 How to Put Y our Ceiling Fan T ogether (pages 9 & 10) 1. Remove the 10-24 x 3/8” pan head screw with lockwasher nearest the hook from the ceiling mounting plate and retain for later use. Loosen the remaining two 10-24 x 3/8” pan head screws several turns.
How to Put Y our Ceiling Fan T ogether (pages 10 & 1 1) EMERSON QUICK ST ART GUIDE NOTE: Electric connections should be in accordance with the National Electrical Codes and all Local Codes. Before starting, disconnect power to the circuit at the fuse box or circuit breaker panel.
Unpac king Instr uctions 1. Open carton containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a.
7 Electrical R equir ements Ho w to Hang Y our Ceiling F an If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
8 Ho w to W ir e Y our Ceiling F an FAN MOTOR ASSEMBL Y CEILING MOUNTING PLA TE HOOK RADIAL SLOT HOLE Figure 3 FAN MOTOR ASSEMBL Y SUPPL Y BLACK WIRE SUPPL Y WHITE WIRE SUPPL Y GREEN WIRE FAN MOTOR BLUE WIRE FAN MOTOR BLACK WIRE FAN MOTOR WHITE WIRE Figure 4 1.
9 U.L. Model No.: CF905 FAN MOTOR ASSEMBL Y KEY HOLE SLOT 10-24 x 3/8" PAN HEAD SCREW WITH LOCKWASHER (3) Figure 5 1. Remove the 10-24 x 3/8” pan head screw with lockwasher nearest the hook from the ceiling mounting plate and retain for later use.
10 U.L. Model No.: CF905 Ho w to Put Y our Ceiling F an T ogether (continued) CEILING TRIM RING FAN HOUSING COVER MOUNTING SCREW HEADS Figure 9 FAN BLADE 10-24 x 5/16" WASHER HEAD BLADE SCREW (3) BLADE FLANGE Figure 10 9.
11 U.L. Model No.: CF905 Ho w to Put Y our Ceiling F an T ogether (continued) SWITCH HOUSING ASSEMBL Y MOUNTING SCREWS (4) Figure 13 14. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate.
W all Control Installation 12 U.L. Model No.: CF905 This control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.
13 U.L. Model No.: CF905 Ener gy Ef ficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan. Here are a few tips to ensure quality and product performance. Choosing the Appropriate Mounting Location.
14 U.L. Model No.: CF905 T r ouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1.
15 U.L. Model No.: CF905 R epair Par ts 3 8 13 15 2 1 10 4 9 5 12 6 7 14 4 0 3 2 1 11 Key Model Numbers No. Description CF905BS00 CF905CK00 CF905GES00 CF905ORB00 CF905VNB00 1 Ceiling Mounting Plate 76.
Part No. F40BP74320000 Printed in China 01/11 Form No. BP7432 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 U.
An important point after buying a device Emerson CF905BS00 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson CF905BS00 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson CF905BS00 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson CF905BS00 you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson CF905BS00 will certainly help you make a decision on the purchase.
If you already are a holder of Emerson CF905BS00, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson CF905BS00.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson CF905BS00. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson CF905BS00 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center