Part No. F40BP74070000 Form No. BP7407 UL Model No.: CF144 & CF152 READ AND SA VE THESE INSTRUCTIONS CUR V A SKY ™ 44” & 52” Damp & W et Loca tion Snugger Ceiling F an Owner's M.
WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference.
3 THE F AN MODELS CF144BS, CF144CRM, CF152BS & CF152CRM ARE SUIT ABLE FOR DAMP LOCA TIONS SUCH AS COVERED PORCHES, COVERED P A TIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. THE F AN MODELS CF144WW , CF144ORB, CF152WW & CF152ORB ARE SUIT ABLE FOR WET LOCA TIONS SUCH AS PORCHES, P A TIOS, AND DECKS.
4 2. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. B. CEILING TRIM RING D. F AN BLADES (3) G. GLASS SHADE A. F AN MOTOR ASSEMBL Y H. NO-LIGHT COVER PLA TE E. LOWER HOUSING K. 50W MINI CANDELABRA HALOGEN BULBS L.
5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
CEILING FLOOR AT LEAST 7' Figure 5 6 UL Model No.: CF144 & CF152 9. T uck the wires and connectors into the fan housing. Position the light kit plate into the fan housing by placing the cut out notches over the fan housing dimples (Figure 4).
7 UL Model No.: CF144 & CF152 2. Pull the electrical supply black, white and ground wires through the center opening of the ceiling mounting plate before securing the plate to the outlet box (Figure 6). 3. Position the ceiling mounting plate onto the outlet box and secure using the two outlet box screws, supplied with outlet box (Figure 6).
UL Model No.: CF144 & CF152 3. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other inside of the outlet box.
1. Screw in two 50-watt (maximum) halogen mini candelabra base bulbs in the light kit plate sockets (Figure 13). 50-WA TT (maximum) HALOGEN MINI CANDELABRA BASE BULBS (2) LIGHT KIT PLA TE SOCKETS (2) Figure 13 2.
10 UL Model No.: CF144 & CF152 General Y our Emerson Ceiling Fan/Light Remote Control consists of hand-held transmitter and a receiver which is mounted under the fan ceiling cover . The remote control is designed to separately control your ceiling fan speed and light intensity .
11 UL Model No.: CF144 & CF152 Setting Operating F r equency of R emote Control 1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.
UL Model No.: CF144 & CF152 12 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
UL Model No.: CF144 & CF152 13 Fan/Light Fails to Operate • Check that the speed switch on the fan is set to HIGH ( .... ) speed. • Check that the light switch is on. • Check that the battery is good (red indicator light should light when any button is pressed).
14 UL Model No.: CF144 & CF152 Damp Part Numbers Wet Part Numbers Key Model No. Model No. Model No. Model No. Model No. Model No. Model No. Model No.
15 UL Model No.: CF144 & CF152 R epair Par ts 2 3 15 8 - 52" 9 - 44" 1 14 4 5 6 5 10 16 13 17 12 11 Before discarding packaging material, be certain all parts have been removed.
LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
An important point after buying a device Emerson CF152WW00 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson CF152WW00 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson CF152WW00 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson CF152WW00 you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson CF152WW00 will certainly help you make a decision on the purchase.
If you already are a holder of Emerson CF152WW00, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson CF152WW00.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson CF152WW00. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson CF152WW00 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center