Programmer’s Reference
April 2008

© Copyright 2008 Emerson
All rights reserved.
Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2008 Emerson Electric Co.
All other trademarks are the property of their respective owners.
Intel® is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
PICMG®, CompactPCI®, AdvancedTCA™ and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI Industrial Computer Manufacturers Group.
While reasonable efforts have been made to assure the accuracy of this document, Emerson assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to a Emerson website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise altered without the permission of Emerson,
It is possible that this publication may contain reference to or information about Emerson products (machines and programs), programming, or services that are not available in your country. Such references or information must not be construed to mean that Emerson intends to announce such Emerson products, programming, or services in your country.
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply unless otherwise agreed to in writing by Emerson.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and Documentation clause at DFARS 252.227-7014 (Jun. 1995).
Emerson Network Power - Embedded Computing
2900 South Diablo Way, Suite 190
Tempe, AZ 85282


Table 1-1 Supported Global IPMI Commands 15 Table 1-2 Supported BMC WatchDog Timer Commands 16 Table 1-3 Supported BMC Device and Messaging Commands 16 Table 1-4 Supported Chassis Device Commands 17 Table 1-5 Supported Event Commands 17 Table 1-6 Supported PEF and Alerting Commands 17 Table 1-7 Supported Sensor Device Commands 18 Table 1-8 Supported FRU Commands 19 Table 1-9 Supported SDR Device Commands 19 Table 1-10 Supported SEL Commands 19 Table 1-11 Supported LAN Device Commands 20 Table 1-12 Supported Serial/Modem Device Commands 20 Table 1-13 Supported PICMG 3.0 Commands 21 Table 1-14 OEM Command Summary 22 Table 1-15 Get Shelf Configuration Record (Cmd = 0x01) 22 Table 1-16 Shelf Manager Switchover (Cmd = 0x02) 23 Table 1-17 Set FRU Extracted (Cmd = 0x03) 23 Table 2-1 Total Power Consumption for AXP 1406 and AXP1600 Shelves 25 Table 2-2 SAM Physical Power Configuration 28 Table 2-3 Sensor Overview 29 Table 2-4 Sensor No. 2 Vbat 30 Table 2-5 Sensor No. 3 3.3 V Voltage 31 Table 2-6 Sensor No. 4 +12 V Voltage 31 Table 2-7 Sensor No. 5 +1.8 V 32 Table 2-8 Sensor No. 6 MAX6656 INT@1A 32 Table 2-9 Sensor No. 7 MAX6656 EXT1@1A 33 Table 2-10 Sensor No. 8 MAX6656 EXT2@1A 34 Table 2-11 Sensor No. 0 FRU 0 HOT_SWAP 35 Table 2-12 Sensor No. 1 IPMB Link 35 Table 2-13 Sensor No. 9 PEM A 36 Table 2-14 Sensor No. 10 PEM B 37 Table 2-15 Sensor No. 11 NSC A (AXP1600 Only) 37 Table 2-16 Sensor No. 12 NSC B (AXP1600 Only) 38 Table 2-17 Sensor No. 13 AXP Backplane ID 39 Table 2-18 Sensor No. 14 12 V B Valid 39 Table 2-19 Sensor No. 15 12 V A Valid 40 Table 2-20 Sensor No. 16 Fault Event 41 Table 2-21 Sensor No. 17 POST Results 41 Table 2-22 Sensor No. 18 Shelf FRU Info 42 Table 2-23 Sensor No. 128 CPLD State 43

Table 2-24 SAM1000 Active Power Configuration 56 Table 2-25 Active SAM1000 Sensor Overview 56 Table 2-26 Sensor No. 141 (0x8D) FT 1 Fan 1 61 Table 2-27 Sensor No. 142 (0x8E) FT 1 Fan 2 61 Table 2-28 Sensor No. 143 (0x8F) FT 2 Fan 1 62 Table 2-29 Sensor No. 144 (0x90) FT2 Fan 2 62 Table 2-30 Sensor No. 145 (0x91) FT 3 Fan 1 63 Table 2-31 Sensor No. 146 (0x92) FT 3 Fan 2 63 Table 2-32 Sensor No. 147 (0x93) FT 4 Fan 1 64 Table 2-33 Sensor No. 148 (0x94) FT 4 Fan 2 64 Table 2-34 Sensor No. 149 (0x95) FT 5 Fan 1 65 Table 2-35 Sensor No. 150 (0x96) FT 5 Fan 2 65 Table 2-36 Sensor No. 151 (0x97) FT 6 Fan 1 66 Table 2-37 Sensor No. 152 (0x98) FT 6 Fan 2 66 Table 2-38 Sensor No. 153 (0x99) FT 7 Fan 1 67 Table 2-39 Sensor No. 154 (0x9A) FT 7 Fan 2 67 Table 2-40 Sensor No. 155 (0x9B) FT 8 Fan 1 68 Table 2-41 Sensor No. 156 (0x9C) FT 8 Fan 2 68 Table 2-42 Sensor No. 157 (0x9D) FT 9 Fan 1, AXP1600 69 Table 2-43 Sensor No. 158 (0x9E) FT 9 Fan 2, AXP1600 70 Table 2-44 Sensor No. 171 (0xAB) FT 1 Fan 1 12 V 70 Table 2-45 Sensor No. 172 (0xAC) FT 1 Fan 1 VBias 71 Table 2-46 Sensor No. 173 (0xAD) FT 1 Fan 2 12 V 71 Table 2-47 Sensor No. 174 (0xAE) FT 1 Fan 2 VBias 72 Table 2-48 Sensor No. 175 (0xAF) FT 2 Fan 1 12 V 73 Table 2-49 Sensor No. 176 (0xB0) FT 2 Fan 1 VBias 73 Table 2-50 Sensor No. 177 (0xB1) FT 2 Fan 2 12 V 74 Table 2-51 Sensor No. 178 (0xB2) FT 2 Fan 2 VBias 74 Table 2-52 Sensor No. 179 (0xB3) FT 3 Fan 1 12 V 75 Table 2-53 Sensor No. 180 (0xB4) FT 3 Fan 1 VBias 76 Table 2-54 Sensor No. 181 (0xB5) FT 3 Fan 2 12 V 76 Table 2-55 Sensor No. 182 (0xB6) FT 3 Fan 2 VBias 77 Table 2-56 Sensor No. 183 (0xB7) FT 4 Fan 1 12 V 77 Table 2-57 Sensor No. 184 (0xB8) FT 4 Fan 1 VBias 78 Table 2-58 Sensor No. 185 (0xB9) FT 4 Fan 2 12 V 79 Table 2-59 Sensor No. 186 (0xBA) FT 4 Fan 2 VBias 79 Table 2-60 Sensor No. 187 (0xBB) FT 5 Fan 1 12 V 80 Table 2-61 Sensor No. 188 (0xBC) FT 5 Fan 1 VBias 80 Table 2-62 Sensor No. 189 (0xBD) FT 5 Fan 2 12 V 81 Table 2-63 Sensor No. 190 (0xBE) FT 5 Fan 2 VBias 82 Table 2-64 Sensor No. 191 (0xBF) FT 6 Fan 1 12 V 82 Table 2-65 Sensor No. 192 (0xC0) FT 6 Fan 1 VBias 83 Table 2-66 Sensor No. 193 (0xC1) FT 6 Fan 2 12 V 83 Table 2-67 Sensor No. 194 (0xC2) FT 6 Fan 2 VBias 84 Table 2-68 Sensor No. 195 (0xC3) FT 7 Fan 1 +12V 85 Table 2-69 Sensor No. 196 (0xC4) FT 7 Fan 1 VBias 85
List of Tables

Table 2-70 Sensor No. 197 (0xC5) FT 7 Fan 2 12 V 86 Table 2-71 Sensor No. 198 (0xC6) FT 7 Fan 2 VBias 86 Table 2-72 Sensor No. 199 (0xC7) FT 8 Fan 1 12 V 87 Table 2-73 Sensor No. 200 (0xC8) FT 8 Fan 1 VBias 88 Table 2-74 Sensor No. 201 (0xC9) FT 8 Fan 2 12 V 88 Table 2-75 Sensor No. 202 (0xCA) FT 8 Fan 2 VBias 89 Table 2-76 Sensor No. 203 (0xCB) FT 9 Fan 1 12 V, AXP1600 90 Table 2-77 Sensor No. 204 (0xCC) FT 9 Fan 1 VBias, AXP1600 90 Table 2-78 Sensor No. 205 (0xCD) FT 9 Fan 2 12 V, AXP1600 91 Table 2-79 Sensor No. 206 (0xCE) FT 9 Fan 2 VBias, AXP1600 91 Table 2-80 Sensor No. 0 (0x00) FRU 0 HOT_SWAP 93 Table 2-81 Sensor No. 2 (0x02) FRU 1 HOT_SWAP 93 Table 2-82 Sensor No. 3 (0x03) FRU 2 HOT_SWAP 94 Table 2-83 Sensor No. 4 (0x04) FRU 3 HOT_SWAP 94 Table 2-84 Sensor No. 5 (0x05) FRU 4 HOT_SWAP 95 Table 2-85 Sensor No. 6 (0x06) FRU 5 HOT_SWAP 95 Table 2-86 Sensor No. 7 (0x07) FRU 6 HOT_SWAP 96 Table 2-87 Sensor No. 8 (0x08) FRU 7 HOT_SWAP 97 Table 2-88 Sensor No. 9 (0x09) FRU 8 HOT_SWAP 97 Table 2-89 Sensor No. 10 (0x0A) FRU 9 HOT_SWAP, AXP1600 98 Table 2-90 Sensor No. 11 (0x20) Fault Event Sensor 98 Table 2-91 Sensor No. 12 (0x0B) IPMB LINK 1 99 Table 2-92 Sensor No. 13 (0x0C) IPMB LINK 2 100 Table 2-93 Sensor No. 14 (0x0D) IPMB LINK 3 100 Table 2-94 Sensor No. 15 (0x0E) IPMB LINK 4 101 Table 2-95 Sensor No. 16 (0x0F) IPMB LINK 5 101 Table 2-96 Sensor No. 17 (0x10) IPMB LINK 6 102 Table 2-97 Sensor No. 18 (0x11) IPMB LINK 7 103 Table 2-98 Sensor No. 19 (0x12) IPMB LINK 8 103 Table 2-99 Sensor No. 20 (0x14) IPMB LINK 9 104 Table 2-100 Sensor No. 21 (0x14) IPMB LINK 10 104 Table 2-101 Sensor No. 22 (0x15) IPMB LINK 11 105 Table 2-102 Sensor No. 23 (0x16) IPMB LINK 12 106 Table 2-103 Sensor No. 24 (0x17) IPMB LINK 13 106 Table 2-104 Sensor No. 25 (0x18) IPMB LINK 14 107 Table 2-105 Sensor No. 26 (0x19) IPMB LINK 15, AXP1600 108 Table 2-106 Sensor No. 27 (0x1A) IPMB LINK 16, AXP1600 108 Table 2-107 Sensor No. 28 (0x1B) IPMB LINK 17 109 Table 2-108 Sensor No. 29 (0x1C) IPMB LINK 18, AXP1600 109 Table 2-109 Sensor No. 30 (0x1D) IPMB LINK 19, AXP1600 110 Table 2-110 Sensor No. 31 (0x1E) IPMB LINK 20, AXP1600 111 Table 2-111 Sensor No. 32 (0x1F) IPMB LINK 21, AXP1600 111 Table 2-112 Sensor No. 131 (0x83) TELCO Alarms 112 Table 2-113 Sensor No. 132 (0x84) BMC Watchdog 113 Table 2-114 Sensor No. 133 (0x85) SYSTEM EVENT 113 Table 2-115 Sensor No. 220 (0xDC) Fan Tray 1 114
List of Tables

Table 2-116 Sensor No. 221 (0xDD) Fan Tray 2 115 Table 2-117 Sensor No. 222 (0xDE) Fan Tray 3 115 Table 2-118 Sensor No. 223 (0xDF) Fan Tray 4 116 Table 2-119 Sensor No. 224 (0xE0) Fan Tray 5 116 Table 2-120 Sensor No. 225 (0xE1) Fan Tray 6 117 Table 2-121 Sensor No. 226 (0xE2) Fan Tray 7 117 Table 2-122 Sensor No. 227 (0xE3) Fan Tray 8 118 Table 2-123 Sensor No. 228 (0xE4) Fan Tray 9, AXP1600 118 Table 2-124 Sensor No. 230 (0xE6) FT 1 -48 V Fuse 119 Table 2-125 Sensor No. 231 (0xE7) FT 2 -48 V Fuse 120 Table 2-126 Sensor No. 233 (0xE9) FT 4 -48 V Fuse 120 Table 2-127 Sensor No. 232 (0xE8) FT 3 -48 V Fuse 121 Table 2-128 Sensor No. 234 (0xEA) FT 5 -48 V Fuse 121 Table 2-129 Sensor No. 235 (0xEB) FT 6 -48 V Fuse 122 Table 2-130 Sensor No. 236 (0xEC) FT 7 -48 V Fuse 122 Table 2-131 Sensor No. 237 (0xED) FT 8 -48 V Fuse 123 Table 2-132 Sensor No. 238 (0xEE) FT9 -48 V Fuse, AXP1600 123 Table 2-133 Power Configuration for PEMs 125 Table 2-134 IPMI Sensors on the PEM 126 Table 2-135 Sensor No. 2 +3.3 V 127 Table 2-136 Sensor No. 3 +8 V 127 Table 2-137 Sensor No. 4 +12 V Backplane 128 Table 2-138 Sensor No. 11 +48.0 V Feed 128 Table 2-139 Sensor No. 12 +7.5 V PEM 129 Table 2-140 Sensor No. 13 +8 V PEM Feed 2 130 Table 2-141 Sensor No. 15 +8 V PEM Feed 1 130 Table 2-142 Sensor No. 14 +12 V Current 131 Table 2-143 Sensor No. 10 DS75 Temp 132 Table 2-144 Sensor #0, Hot Swap 132 Table 2-145 Sensor #1, IPMB Physical 133 Table 2-146 Sensor #5, CB 1 134 Table 2-147 Sensor #6 CB 2 134 Table 2-148 Sensor No. 7 CB 3 135 Table 2-149 Sensor No. 8 CB 4 135 Table 2-150 Sensor No. 9 CB 5 136 Table 3-1 Shm Fault Classes 140 Table A-1 FRU State Table for Nonrecoverable Threshold Events from Temperature Sensors . 144 Table B-1 Emerson Newtork Power - Embedded Computing Documents 147 Table B-2 Manufacturers Documents 148 Table B-3 Related Specifications 148
List of Tables

Overview of Contents
The information in this reference guide support both Centellis 3406 and Centellis 3600 platforms. The differences between the two platforms are:
z The AXP1406 is a 14-slot shelf with 2 PEMs, 2 SAMs, and 8 FTMs.
z The AXP1600 is a 16-slot shelf with 2 PEMs, 2 SAMs, and 9 FTMs.
This guide provides FRU data and SDR for each AXP shelf. On the AXP1600 platform, additional sensors are described for FTM FRU 9. All AXP1600 FRU data and sensor information is clearly identified throughout this guide.
The AXP1406 and AXP1600 both have an Intelligent Peripheral Management Controller (IPMC) which is fully compliant to the IPMI V1.5 specification. The IPMC provides access to on- board Sensor Data Records (SDRs), Field Replaceable Unit (FRU) data, and furthermore contains an event generator. Within this document you find a description of:
z Supported IPMI commands
For the last two items in the list, the default values are given for reference purposes if you want to restore the factory values.
This manual is divided into the following chapters and appendices.
Chapter 1, Supported IPMI Commands, lists IPMI commands supported by the IPMC.
Chapter 2, FRU Information and Sensor Data Records, lists the PEM, FTM, and SAM1000 Shelf Manager FRU information, as well as sensors that are accessible via IPMI for both the AXP1406 and AXP1600 shelves.
Chapter 3, OEM Sensors, lists the additional OEM sensors that are accessible via IPMI for both the AXP1406 and AXP1600 shelves.
Appendix A, System Behavior in Response to Sensor Events, describes the shelf manager’s cooling management and FRU state management for nonrecoverable threshold events.
Appendix B, Related Documentation, lists publications for blade and software products used with the Centellis 3406 and 3600 platforms.
z FRU States · z SDRs · z FRU data

This document uses the following terms and abbreviations:
The following table describes the conventions used throughout this manual.
About this Manual

... Repeated item for example node 1, node 2, ..., node 12
Omission of information from example/command that is not necessary at the time being
Indicates a hazardous situation which, if not avoided, could result in death or serious injury


Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury
Indicates a property damage message


No danger encountered. Pay attention to important information
The next table provides information on the changes since the first release of this manual. This edition supersedes all other releases.
Date Description of Change Replaces
April 2008 Updated to Emerson style. 6806800B66B
April 2007 Shm Fault Event OEM Sensor added. 6806800B66A
About this Manual · | Logical OR

We welcome and appreciate your comments on our documentation. We want to know what you think about our manuals and how we can make them better.
Mail comments to us by filling out the following online form: http://www.emersonnetworkpowerembeddedcomputing.com/ > Contact Us > Online Form
In “Area of Interest” select “Technical Documentation”. Be sure to include the title, part number, and revision of the manual and tell us how you used it.
About this Manual

1.1 Introduction
This chapter describes the different commands supported by the Centellis 3000 series platforms. Command categories are as follows:
z Standard IPMI Commands
z PICMG 3.0 Commands
z Emerson and Pigeon Point OEM Commands
The IPMC is fully compliant to the Intelligent Platform Management Interface v.1.5. This section provides information on which IPMI commands are supported. Table entries marked with an “x” indicate which FRU or ATCA blade supports a listed command.
The IPMC supports the following global IPMI commands.
Table 1-1 Supported Global IPMI Commands
Physical ShelfMgr PEMs FTMs
NetFn Rq/Rs Command CMD
Get Device ID 0x06/0x07 0x01 X
Cold Reset 0x06/0x07 0x02 X
Warm Reset 0x06/0x07 0x03 X X X
Get Self Test Result 0x06/0x07 0x04 X
Set ACPI Power State 0x06/0x07 0x06 X X *
Get ACPI Power State 0x06/0x07 0x07 X X *
Get Device GUID 0x06/0x07 0x08 X
Active ShelfMgr · ATCA Blades

Supported IPMI Commands BMC WatchDog Timer Commands
The IPMC supports the following BMC WatchDog Timer commands.
Table 1-2 Supported BMC WatchDog Timer Commands
Physical ShelfMgr PEMs FTMs
Reset Watchdog Timer 0x06/0x07 0x22 X X X
Set Watchdog Timer 0x06/0x07 0x24 X X X
Get Watchdog Timer 0x06/0x07 0x25 X X X
The IPMC supports the following BMC device and messaging commands.
Table 1-3 Supported BMC Device and Messaging Commands
Physical ShelfMgr PEMs FTMs
Set BMC Global Enables 0x06/0x07 0x2E X
Get BMC Global Enables 0x06/0x07 0x2F X
Clear Message Flags 0x06/0x07 0x30 X
Get Message Flags 0x06/0x07 0x31 X
Send Message 0x06/0x07 0x34 X
Get System GUID 0x06/0x07 0x37 X
Get Channel Authentication Capabilities
0x06/0x07 0x38 X
Get Session Challenge 0x06/0x07 0x39 X
Activate Session 0x06/0x07 0x3A X
Set Session Privilege Level 0x06/0x07 0x3B X
Close Session 0x06/0x07 0x3C X
Get Session Info 0x06/0x07 0x3D X
Get AuthCode 0x06/0x07 0x3F X
Set Channel Access 0x06/0x07 0x40 X
Get Channel Access 0x06/0x07 0x41 X
Get Channel Info Command 0x06/0x07 0x42 X
Set User Access Command 0x06/0x07 0x43 X
Get User Access Command 0x06/0x07 0x44 X
Set User Name 0x06/0x07 0x45 X
Get User Name Command 0x06/0x07 0x46 X
Set User Password Command 0x06/0x07 0x47 X

Chassis Device Commands Supported IPMI Commands
The IPMC supports the following chassis device commands.
Table 1-4 Supported Chassis Device Commands
Physical ShelfMgr PEMs FTMs
Get Chassis Capabilities 0x00/0x01 0x00 X X
Get Chassis Status 0x00/0x01 0x01 X X
Chassis Control 0x00/0x01 0x02 X X
Set Chassis Capabilities 0x00/0x01 0x05 X X
Set System Boot Options* 0x00/0x01 0x08 X
Get System Boot Options* 0x00/0x01 0x09 X
*The data portion of these commands are blade-specific. Refer to the respective blade specification.
The IPMC supports the following event commands.
Table 1-5 Supported Event Commands
Physical ShelfMgr PEMs FTMs
Command NetFn Rq/Rs CMD
Set Event Receiver 0x04/0x05 0x00 X
Get Event Receiver 0x04/0x05 0x01 X
Platform Event (a.k.a. “Event Message”)
0x04/0x05 0x02 X X *
*ATCA-F101 supports this command.
The IPMC supports the following PEF and alerting commands.
Table 1-6 Supported PEF and Alerting Commands
Physical ShelfMgr PEMs FTMs
Get PEF Capabilities 0x04/0x05 0x10 X X
Arm PEF Postpone Timer 0x04/0x05 0x11 X X
Set PEF Configuration Parameters 0x04/0x05 0x12 X X
Get PEF Configuration Parameters 0x04/0x05 0x13 X X

Supported IPMI Commands Sensor Device Commands
Table 1-6 Supported PEF and Alerting Commands (continued)
Physical ShelfMgr PEMs FTMs
Set Last Processed Event ID 0x04/0x05 0x14 X X
Get Last Processed Event ID 0x04/0x05 0x15 X X
Alert Immediate 0x04/0x05 0x16 X X
PET Acknowledge 0x04/0x05 0x17 X X
The IPMC supports the following sensor device commands.
Table 1-7 Supported Sensor Device Commands
Physical ShelfMgr PEMs FTMs
Get Device SDR Info 0x04/0x05 0x20 X
Get Device SDR 0x04/0x05 0x21 X
Reserve Device SDR Repository 0x04/0x05 0x22 X
Get Sensor Reading Factors 0x04/0x05 0x23 X
Set Sensor Hysteresis 0x04/0x05 0x24 X
Get Sensor Hysteresis 0x04/0x05 0x25 X
Set Sensor Threshold 0x04/0x05 0x26 X
Get Sensor Threshold 0x04/0x05 0x27 X
Set Sensor Event Enable 0x04/0x05 0x28 X
Get Sensor Event Enable 0x04/0x05 0x29 X
Re-arm Sensor Events 0x04/0x05 0x2a X X *
Get Sensor Event Status 0x04/0x05 0x2b X
Get Sensor Reading 0x04/0x05 0x2d X
Set Sensor Type 0x04/0x05 0x2e X X *
Get Sensor Type 0x04/0x05 0x2f X
*ATCA-F101 Supports this command.

FRU Device Commands Supported IPMI Commands
The IPMC supports the following FRU device commands.
Table 1-8 Supported FRU Commands
Physical ShelfMgr PEMs FTMs
Command NetFn Rq/Rs CMD
Get FRU Inventory Area Info 0x0A/0x0B 0x10 X
Read FRU Data 0x0A/0x0B 0x11 X
Write FRU Data 0x0A/0x0B 0x12 X
The IPMC supports the following SDR device commands.
Table 1-9 Supported SDR Device Commands
Physical ShelfMgr PEMs FTMs
Get SDR Repository Info 0x0A/0x0B 0x20 X
Get SDR Repository Allocation Info
Reserve SDR Repository 0x0A/0x0B 0x22 X
Get SDR 0x0A/0x0B 0x23 X
Add SDR 0x0A/0x0B 0x24 X
Partial Add SDR 0x0A/0x0B 0x25 X
Delete SDR 0x0A/0x0B 0x26 X
Clear SDR Repository 0x0A/0x0B 0x27 X
Get SDR Repository Time 0x0A/0x0B 0x28 X
Set SDR Repository Time 0x0A/0x0B 0x29 X
The IPMC supports the following SEL device commands.
Table 1-10 Supported SEL Commands
Physical ShelfMgr PEMs FTMs
Get SEL Info 0x0A/0x0B 0x40 X
Get SEL Allocation Info 0x0A/0x0B 0x41 X
Reserve SEL 0x0A/0x0B 0x42 X
Get SEL Entry 0x0A/0x0B 0x43 X X

Supported IPMI Commands LAN Device Commands
Table 1-10 Supported SEL Commands (continued)
Physical ShelfMgr PEMs FTMs
Add SEL Entry 0x0A/0x0B 0x44 X X
Partial Add SEL Entry 0x0A/0x0B 0x45 X X
Delete SEL Entry 0x0A/0x0B 0x46 X X
Clear SEL 0x0A/0x0B 0x47 X X
Get SEL Time 0x0A/0x0B 0x48 X
Set SEL Time 0x0A/0x0B 0x49 X X
The IPMC supports the following LAN device commands.
Table 1-11 Supported LAN Device Commands
Physical ShelfMgr PEMs FTMs
Set LAN Configuration Parameters 0x0C/0x0D 0x01 X
Get LAN Configuration Parameters 0x0C/0x0D 0x02 X
Suspend BMC ARPs 0x0C/0x0D 0x03 X
The IPMC supports the following serial/modem device commands.
Table 1-12 Supported Serial/Modem Device Commands
Physical ShelfMgr PEMs FTMs
Command NetFn Rq/Rs CMD
Set User Callback Options 0x0C/0x0D 0x1A X
Get User Callback Options 0x0C/0x0D 0x1B X

PICMG 3.0 Commands Supported IPMI Commands
The Emerson IPMC is a fully compliant AdvancedTCA Intelligent Platform Management Controller. For example, it supports all required and mandatory AdvancedTCA commands as defined in the PICMG 3.0 specification.
Table 1-13 Supported PICMG 3.0 Commands
Physical ShelfMgr PEMs FTMs
Command NetFn Rq/Rs CMD
Get PICMG Properties 0x2C/0x2D 0x00 X
Get Address Info 0x2C/0x2D 0x01 X
Get Shelf Address Info 0x2C/0x2D 0x02 X X
Set Shelf Address Info 0x2C/0x2D 0x03 X X
FRU Control 0x2C/0x2D 0x04 X
Get FRU LED Properties 0x2C/0x2D 0x05 X X X
Get LED Color Capabilities 0x2C/0x2D 0x06 X X X
Set FRU LED State 0x2C/0x2D 0x07 X X X
Get FRU LED State 0x2C/0x2D 0x08 X X X
Set IPMB State 0x2C/0x2D 0x09 X
Set FRU Activation Policy 0x2C/0x2D 0x0A X
Get FRU Activation Policy 0x2C/0x2D 0x0B X
Set FRU Activation 0x2C/0x2D 0x0C X
Get Device Locator Record ID
0x2C/0x2D 0x0D X
Set Port State 0x2C/0x2D 0x0E X X X
Get Port State 0x2C/0x2D 0x0F X X X
Compute Power Properties 0x2C/0x2D 0x10 X
Set Power Level 0x2C/0x2D 0x11 X
Get Power Level 0x2C/0x2D 0x12 X
Renegotiate Power 0x2C/0x2D 0x13 X
Get Fan Speed Properties 0x2C/0x2D 0x14 X
Set Fan Level 0x2C/0x2D 0x15 X
Get Fan Level 0x2C/0x2D 0x16 X
Bused Resource 0x2C/0x2D 0x17 X X
Get IPMB Link Info 0x2C/0x2D 0x18 X X
Active ShelfMgr · ATCA Blades

Supported IPMI Commands Emerson and Pigeon Point OEM Commands
These commands can only be sent to the Emerson AXP1406 and AXP1600 Shelf Managers, sending these commands to other shelf managers or IPMCs will result in error responses or undefined behavior.
The SAM supports these OEM IPMI commands that are not defined in the IPMI 1.5 or PICMG 3.0 specifications.
Table 1-14 OEM Command Summary
IPMI NetFn (Request/Response) Emerson OEM Command IPMI Cmd
Get Shelf Configuration Record 0x2E / 0x2F 0x01
Shelf Manager Switchover 0x2E / 0x2F 0x02
Set FRU Extracted 0x2E / 0x2F 0x03
This command gets the shelf configuration for the AXP1600.
Table 1-15 Get Shelf Configuration Record (Cmd = 0x01)
Request data 1 Pigeon Point Systems IANA Enterprise number, LSB first
4 IANA enterprise number for the desired record, LSB first
9 Offset within record
10 Count of bytes to retrieve
2 Pigeon Point Systems IANA Enterprise number, LSB first
5 Requested bytes from the specified Shelf FRU record

Emerson and Pigeon Point OEM Commands Supported IPMI Commands
This command requests a SAM switchover.
Table 1-16 Shelf Manager Switchover (Cmd = 0x02)
Request data 1 Pigeon Point Systems IANA Enterprise number, LSB first
4 Flags 0x00 Switchover, but do not reboot the active Shelf Manager
0x01 Switchover, and reboot the active Shelf Manager
Response data 1 Completion Code
This command instructs the SAM to transition a FRU to the M0 (not installed) state.
Table 1-17 Set FRU Extracted (Cmd = 0x03)
Request data 1 Pigeon Point Systems IANA Enterprise number, LSB first
6 Force option 0x00 Only extract specified FRU if it is in M7 state 0x01 Extract the specified FRU regardless of its current state
Response data 1 Completion Code
2 Pigeon Point Systems IANA Enterprise number, LSB first

Supported IPMI Commands Emerson and Pigeon Point OEM Commands

2.1 Introduction
This chapter introduces FRU information, e-keying, sensor overviews, and power configuration data for each subcomponent of the AXP1406 and AXP1600 shelf. Information in this chapter also includes:
z Total Power Consumption
z SAM1000 Physical Shelf Manager
z SAM1000 Active (Virtual) Shelf Manager
z Power Entry Module Sensor Data Records
Subcomponents include the Power Entry Modules (PEMs), upper and lower Fan Tray Modules (FTMs), and the SAM1000 Shelf Management Alarm Module (SAMs), both physical and active.
All fan tray sensors are exposed by the Active SAM.
The following table shows the total power requirements for the shelf. Power consumption breakdown is shown in the next table.
Table 2-1 Total Power Consumption for AXP 1406 and AXP1600 Shelves
Amps per Fan Maximum Total Watts
AXP1406 Shelf 8 FTMs without AdvancedTCA Blades 400 Watts
AXP1600 Shelf 9 FTMs without AdvancedTCA Blades 400 Watts
Assumes the shelf is configured with 2 SAMs, 2 PEMs, and all FTMs running at full speed.

FRU Information and Sensor Data Records SAM1000 Physical Shelf Manager
This section describes in detail the physical SAM Shelf Manager, FRU data, power configuration and sensors at IPMB addresses 0xFC and 0xFE. The information in this section supports the SAM on both the AXP1406 and AXP1600 shelves. The AXP1600 FRU and sensor data is highlighted and marked for ease of use.
The following tables provides the FRU information for the physical SAM on the AXP1406 and AXP1600 shelves.
Internal Use Area:
Board Info Area:
Language Code = 25
Mfg Date/Time = Mar 30 23:00:00 2005 (4862820 minutes since 1996)
Board Manufacturer = Pigeon Point Systems
Board Product Name = IPM Sentry ShMM-500
Board Serial Number = PPS0000000
Board Part Number = A
FRU Programmer File ID =
Product Info Area:
Language Code = 25
Manufacturer Name = Pigeon Point Systems
Product Name = IPM Sentry Shelf Manager
Product Part / Model# = 000000
Product Version = Rev 1.00
Product Serial Number = PPS0000000

SAM Physical FRU Information FRU Information and Sensor Data Records
FRU Programmer File ID =
Multi Record Area:
PICMG Board Point-to-Point Connectivity Record (ID=0x14)
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1996)
Board Manufacturer = Pigeon Point Systems
Board Product Name = IPM Sentry ShMM-500
Board Serial Number = 08000000
Board Part Number = 01-W3911F11B
FRU Programmer File ID = SAM1000R.inf
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = SAM1000
Product Part / Model# = 01-W2313F11A
Product Version = Rev 1.00
Product Serial Number = 12345678901
FRU Programmer File ID = SAM1000R.inf
Multi Record Area:
PICMG Board Point-to-Point Connectivity Record (ID=0x14)

FRU Information and Sensor Data Records E-Keying
The physical SAMs (IPMB 0xfc and 0xfe) each contain the following Point-to-Point Connectivity Record:
PICMG Board Point-to-Point Connectivity Record (ID=0x14)
OEM GUID Count = 0
Link Descriptor:
Link Grouping ID = 0x00
Link Type = 0x01 PICMG®3.0 Base 10/100/1000 Base-T
Link Type Extension = 0x0 10/100/1000BASE-T Link (four-pair)
Link Designator = 0x101 Channel1/BaseInterface/Ports0
Link Descriptor:
Link Grouping ID = 0x00
Link Type = 0x01 PICMG®3.0 Base 10/100/1000 Base-T
Link Type Extension = 0x0 10/100/1000BASE-T Link (four-pair)
Link Designator = 0x102 Channel2/BaseInterface/Ports0
The following table describes the power configuration for the Physical SAM.
Table 2-2 SAM Physical Power Configuration
Dynamic power reconfiguration support
No Possibility to change FRU power consumption without switching it off, according to ATCA
Dynamic power configuration No Are the Power Draw levels fixed or these may vary if additional components are hot inserted or onboard components power consumption is changing dynamically
Number of Power Draw Levels 1 The amount of possible power levels, normally 1
Early Power Draw Levels, Watt 20 Complete early power consumption including IPMC
Steady state Power Draw Levels, Watt
20 Complete steady power consumption including IPMC
Transition from Early to Steady levels, sec
0 How long does board consumes early power. Early power is normally bigger than steady
Version = 0 · Item Value Meaning

Sensor Overview FRU Information and Sensor Data Records
The following table lists all IPMI sensors available on the physical SAM at IPMB addresses 0xFC and 0xFE. The information in this section supports the SAM on both the AXP1406 and AXP1600 shelves. The AXP1600 FRU and sensor data is highlighted and marked for ease of use.
Table 2-3 Sensor Overview
Sensor No. Sensor Name
What does it measure?
0 FRU 0 HOT_SWAP Status State of FRU Discrete Always
1 IPMB LINK Status State of IPMB link Discrete Always
2 Vbat Voltage Analog Always
3 Vcc 3.3 V voltage Voltage Analog Always
4 +12 V voltage Voltage Analog Always
5 +1.8 V Voltage Analog Always
6 MAX6656 INT @1A Temperature Analog Always
7 MAX6656 EXT1 @1A Temperature Analog Always
8 MAX6656 EXT2 @1A Temperature Analog Always
9 PEM A Status PEM A Presence Discrete Always
10 PEM B Status PEM B Presence Discrete Always
Status NSC Board Presence
12 NSC B1 Status NSC Board Presence
13 AXP Backplane ID OEM Backplane Bus Type
14 12 V In B Valid Status Power Unit Discrete Always
15 12 V In A Valid Status Power Unit Discrete Always
16 Fault Event OEM Shelf Manager Rebooting Notifier
17 POST Results Status Management Subsystem Health
18 Shelf FRU Info OEM Shelf Fru Info Validity
128 CPLD State OEM Master and Backup Shelf Manager State

FRU Information and Sensor Data Records SAM Physical Shelf Manager Analog Sensors
The physical shelf managers at IPMB addresses 0xFC and 0xFE present the following analog sensors:
The following tables describe the analog sensors available on the physical SAM. The information in this section supports the SAM on both the AXP1406 and AXP1600 shelves. The AXP1600 FRU and sensor data is highlighted and marked for ease of use.
The following table describes the analog voltage sensors on the physical SAM.
Table 2-4 Sensor No. 2 Vbat
Sensor Type 0x02 Voltage
Entity ID 0xF0 PICMG Shelf Management Controller
Threshold access support Readable/Settable
Settable threshold mask (bytes 19, 20) 0x12, 0x12 Upper and Lower Critical Thresholds are Readable and Settable
Lower critical threshold 0x00 0 Volts
Upper critical threshold 0xFF 3.315 Volts

SAM Physical Shelf Manager Analog Sensors FRU Information and Sensor Data Records
Table 2-5 Sensor No. 3 3.3 V Voltage
Sensor Name Vcc 3.3 V voltage
Sensor Type 0x02 Voltage
Entity ID 0xF0 PICMG Shelf Management Controller
Threshold access support Readable/Settable
Settable threshold mask (bytes 19, 20) 0x12, 0x12 Upper and Lower Critical Thresholds are Readable and Settable
Lower critical threshold 0x73 3.0245 Volts
Upper critical threshold 0x88 3.5768 Volts
Table 2-6 Sensor No. 4 +12 V Voltage
Sensor Name +12 V voltage
Sensor Type 0x02 Voltage
Entity ID 0xF0 PICMG Shelf Management Controller
Threshold access support Readable/Settable

FRU Information and Sensor Data Records SAM Physical Shelf Manager Analog Sensors
Table 2-6 Sensor No. 4 +12 V Voltage (continued)
Settable threshold mask (bytes 19, 20) 0x12, 0x12 Upper and Lower Critical Thresholds are Readable and Settable
Lower critical threshold 0x00 0 Volts
Upper critical threshold 0xFF 15.81 Volts
Table 2-7 Sensor No. 5 +1.8 V
Sensor Name +1.8 V
Type of measurement Voltage
Sensor Type 0x02 Voltage
Entity ID 0xF0 PICMG Shelf Management Controller
Threshold access support Readable/Settable
Settable threshold mask (bytes 19, 20) 0x10, 0x10 Upper Critical Threshold is Readable and Settable
Upper critical threshold 0xFF 2.499 Volts
The following tables describe the analog temperature sensors available on the physical SAM.
Table 2-8 Sensor No. 6 MAX6656 INT@1A
Sensor Name MAX6656 INT @1A
Sensor Type 0x01 Temperature

SAM Physical Shelf Manager Analog Sensors FRU Information and Sensor Data Records
Table 2-8 Sensor No. 6 MAX6656 INT@1A (continued)
Entity ID 0xF0 PICMG Shelf Management Controller
Hysteresis support Readable and Settable
Threshold access support Readable/Settable
Settable threshold mask (bytes 19, 20) 0x38, 0x38 Upper Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Reading Type 2's Complement
Upper Non-Critical, Critical and Non-Recoverable threshold
0x50, 0x5A, 0x64 (80, 90, 100) Centigrade
Table 2-9 Sensor No. 7 MAX6656 EXT1@1A
Sensor Name MAX6656 EXT1 @1A
Sensor Type 0x01 Temperature
Entity ID 0xF0 PICMG Shelf Management Controller
Hysteresis support Readable and Settable
Threshold access support Readable/Settable
Settable threshold mask (bytes 19, 20) 0x38, 0x38 Upper Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Reading Type 2's Complement
Upper Non-Critical, Critical and Non-Recoverable threshold
0x50, 0x5A, 0x64 (80, 90, 100) Centigrade

FRU Information and Sensor Data Records SAM Module Discrete Sensors
Table 2-10 Sensor No. 8 MAX6656 EXT2@1A
Sensor Name MAX6656 EXT2 @1A
Sensor Type 0x01 Temperature
Entity ID 0xF0 PICMG Shelf Management Controller
Hysteresis support Readable and Settable
Threshold access support Readable/Settable
Settable threshold mask (bytes 19, 20) 0x38, 0x38 Upper Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Reading Type 2's Complement
Upper Non-Critical, Critical and Non-Recoverable threshold
0x50, 0x5A, 0x64 (80, 90, 100) Centigrade
The physical shelf managers at IPMB addresses 0xFC and 0xFE present the following discrete sensors:
z Hot Swap Sensor
z IPMB Link Sensor
z PEM A Sensor
z PEM B Sensor
z AXP Backplane ID Sensor
z +12 V B Valid Sensor
z +12 V A Valid Sensor
z Fault Event Sensor
z POST Results Sensor
z Shelf FRU Info Sensor
z CPLD State Sensor
Device · Class 0x01 Threshold · Readable threshold mask,

SAM Module Discrete Sensors FRU Information and Sensor Data Records
The following table describes the discrete hot swap sensor available on the physical SAM.
Table 2-11 Sensor No. 0 FRU 0 HOT_SWAP
Sensor Name FRU 0 HOT_SWAP
Type of Measurement Hot Swap State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15, 16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
The following table describes the discrete IPMB link sensor available on the physical SAM.
Table 2-12 Sensor No. 1 IPMB Link
Sensor Name IPMB LINK
Type of Measurement IPMB Link State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller

FRU Information and Sensor Data Records SAM Module Discrete Sensors
Table 2-12 Sensor No. 1 IPMB Link (continued)
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
The following table describes the discrete PEM A sensor available on the physical SAM.
Table 2-13 Sensor No. 9 PEM A
Sensor Name PEM A
Type of Measurement Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x0A Power Supply
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5

SAM Module Discrete Sensors FRU Information and Sensor Data Records
The following table describes the discrete PEM B sensor available on the physical SAM.
Table 2-14 Sensor No. 10 PEM B
Sensor Name PEM B
Type of Measurement Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x0A Power Supply
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
Two additional NSC Presence sensor support the SAM used in the AXP1600 shelf.
Table 2-15 Sensor No. 11 NSC A (AXP1600 Only)
Sensor Name NSC A
Type of Measurement Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x0B (add-in card) Power Supply

FRU Information and Sensor Data Records SAM Module Discrete Sensors
Table 2-15 Sensor No. 11 NSC A (AXP1600 Only) (continued)
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
Table 2-16 Sensor No. 12 NSC B (AXP1600 Only)
Sensor Name NSC B
Type of Measurement Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x0B (add-in card Power Supply
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5

SAM Module Discrete Sensors FRU Information and Sensor Data Records
The following table describes the discrete AXP backplane ID sensor available on the physical SAM. For more detail on this sensor, refer to AXP Backplane ID (Emerson OEM) on page 138.
Table 2-17 Sensor No. 13 AXP Backplane ID
Sensor Name AXP Backplane ID
Type of Measurement Specifies Bus Type of the Backplane
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xDB OEM-reserved
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x01, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x01 0x00 Supports 1 Successive State
Reading Definition According to Motorola XXXX
The following table describes the discrete +12 V B valid sensor available on the physical SAM.
Table 2-18 Sensor No. 14 12 V B Valid
Sensor Name 12 V In B Valid
Type of Measurement State of Power Unit B
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0x09 Power Unit
Entity ID 0xF0 PICMG Shelf Management Controller

FRU Information and Sensor Data Records SAM Module Discrete Sensors
Table 2-18 Sensor No. 14 12 V B Valid (continued)
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
The following table describes the discrete +12V A valid sensor available on the physical SAM.
Table 2-19 Sensor No. 15 12 V A Valid
Sensor Name 12 V In A Valid
Type of Measurement State of Power Unit A
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0x09 Power Unit
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5

SAM Module Discrete Sensors FRU Information and Sensor Data Records
The following table describes the discrete fault event sensor available on the physical SAM.
Table 2-20 Sensor No. 16 Fault Event
Sensor Name Fault Event
Type of Measurement Reports that the Shelf Manager has Rebooted.
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xDC OEM-reserved
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x01, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x01, 0x00 Supports 1 State
Reading Definition According to Motorola XXX
The following table describes the discrete POST results sensor available on the physical SAM. For more information on this sensor, refer to POST Results (Emerson OEM) on page 138.
Table 2-21 Sensor No. 17 POST Results
Sensor Name POST Results
Type of Measurement POST Results
Event/Reading Type 0x06 'digital' Discrete
Sensor Type 0x28 Management Subsystem Health
Entity ID 0xF0 PICMG Shelf Management Controller

FRU Information and Sensor Data Records SAM Module Discrete Sensors
Table 2-21 Sensor No. 17 POST Results (continued)
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
The following table describes the discrete shelf FRU info sensor available on the physical SAM. For more information on this sensor, refer to Shelf FRU Info (Emerson OEM) on page 139.
Table 2-22 Sensor No. 18 Shelf FRU Info
Sensor Name Shelf FRU Info
Type of Measurement Basic validation of the Shelf FRU Info
Event/Reading Type 0x09 'digital' Discrete
Sensor Type 0xDD OEM-reserved
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Motorola XXX

SAM1000 Active (Virtual) Shelf Manager FRU Information and Sensor Data Records
The following table describes the discrete CPLD state sensor available on the physical SAM.
Table 2-23 Sensor No. 128 CPLD State
Sensor Name CPLD State
Type of Measurement States of the Master and Backup Shelf Managers
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xDE OEM-reserved
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0xF7, 0x07
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xF7, 0x07 Supports 10 States
Reading Definition According to Motorola XXX
This section describes in detail all available IPMI sensors of the Active SAM1000 at IPMB address 0x20. The information in this section supports the SAM on both the AXP1406 and AXP1600 shelves. The AXP1600 FRU and sensor data is highlighted and/or marked for ease of use.
FRU 0 of address 0x20 corresponds to the main FRU information of the respective Physical SAM that is running as the Active SAM; it could be either FRU 0 of IPMB address 0xFC or FRU 0 of IPMB address 0xFE.
Active Shelf Manager FRU Data, AXP1406 There are an additional eight managed FRUs (FRUs 1 to 8) that correspond to each of the eight fan trays that cool the chassis. The Active SAM FRU information is addressed as FRU 254 which is cached information from data stored as a FRU 1 in each of the PEMs (IPMB addresses 0x66 and 0x68).

FRU Information and Sensor Data Records FRU Information
Active Shelf Manager FRU Data, AXP1600 There are an additional nine managed FRUs (FRUs 1 to 9) that correspond to each of the nine fan trays that cool the chassis. The Active SAM FRU information is addressed as FRU 254 which is cached information from data stored as a FRU 1 in each of the PEMs (IPMB addresses 0x66 and 0x68).
The following tables show an example of the output obtained when retrieving FRU information using the CLIA tool of the Active SAM.
# clia fruinfo 20 254
Pigeon Point Shelf Manager Command Line Interpreter
Chassis Info Area:
Chassis Type = (2)
Chassis Part Number = CHS1406
Chassis Serial Number = 0000001
Board Info Area:
Language Code = 25
Mfg Date/Time = Mar 29 00:00:00 2006 (5385600 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = CHS1406
Board Serial Number = 0000001
Board Part Number = CHS1406
FRU Programmer File ID = CHS1406.inf
Product Info Area:
Version = 1 · Version = 1 · Version = 1

FRU Information FRU Information and Sensor Data Records
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1406
Product Part / Model# = CHS1406
Product Version = Rev. 1
Product Serial Number = 0000001
FRU Programmer File ID = CHS1406.inf
Multi Record Area:
PICMG Shelf Manager IP Connection Record (ID=0x13)
Record Type = Management Access Record
PICMG Address Table Record (ID=0x10)
PICMG Backplane Point-to-Point Connectivity Record (ID=0x04)
PICMG Backplane Point-to-Point Connectivity Record (ID=0x04)
PICMG Shelf Power Distribution Record (ID=0x11)
PICMG Radial IPMB-0 Link Mapping Record (ID=0x15)

FRU Information and Sensor Data Records FRU Information
PICMG Shelf Activation And Power Management Record (ID=0x12)
Record Type = 0xc0 OEM Record
Manufacturer ID = 0x0000A1 MOTOROLA
Record ID = 0x02
Pigeon Point Shelf Manager Command Line Interpreter
Chassis Info Area:
Chassis Type = (1)
Chassis Part Number = 01-W1055C12B
Chassis Serial Number = 00001
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1
Board Manufacturer = Motorola
Board Product Name = CHS1600
Board Serial Number = 1234567890
Board Part Number = CHS1600
FRU Programmer File ID = CHS1600R_ShelfFru.inf

FRU Information FRU Information and Sensor Data Records
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1600
Product Part / Model# = CHS1600
Product Version = Rev. 1
Product Serial Number = 00001
FRU Programmer File ID = CHS1600R_ShelfFru.inf
Multi Record Area:
PICMG Shelf Manager IP Connection Record (ID=0x13)
Record Type = Management Access Record
PICMG Address Table Record (ID=0x10)
PICMG Backplane Point-to-Point Connectivity Record (ID=0x04)
PICMG Backplane Point-to-Point Connectivity Record (ID=0x04)
PICMG Backplane Point-to-Point Connectivity Record (ID=0x04)

FRU Information and Sensor Data Records FRU Information
PICMG Shelf Power Distribution Record (ID=0x11)
PICMG Radial IPMB-0 Link Mapping Record (ID=0x15)
PICMG Shelf Activation And Power Management Record (ID=0x12)
Record Type = 0xc0 OEM Record
Manufacturer ID = 0x0000A1 MOTOROLA
Record ID = 0x02
Pigeon Point Shelf Manager Command Line Interpreter
Internal Use Area:
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1996)
Board Manufacturer = Pigeon Point Systems
Board Product Name = IPM Sentry ShMM-500
Board Serial Number = 08000000
Board Part Number = 01-W3911F11B
FRU Programmer File ID = SAM1000R.inf
Product Info Area:

FRU Information FRU Information and Sensor Data Records
Language Code = 25
Manufacturer Name = Motorola
Product Name = SAM1000
Product Part / Model# = 01-W2313F11A
Product Version = Rev 1.00
Product Serial Number = 12345678901
FRU Programmer File ID = SAM1000R.inf
Multi Record Area:
PICMG Board Point-to-Point Connectivity Record (ID=0x14)
There are eight fan trays in the AXP1406 shelf, six of them are located at the top of the shelf and two are located in the bottom. Looking at the shelf from the top; the location of the fan tray FRUs 1 through 6 looks like this:
Figure 2-1 Upper Fan Tray Locations, AXP1406
The bottom fan tray are FRU 7 (left side) and FRU 8 (right side) looking at the shelf from the front.
Figure 2-2 Lower Fan Tray Locations, AXP1406

FRU Information and Sensor Data Records FRU Information
The FRU information for fan trays 1, 2 and 3 is the same (except serial numbers); similarly for fan trays 4, 5 and 6; and for fan trays 7 and 8. This information follows:
Pigeon Point Shelf Manager Command Line Interpreter
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 10 00:00:00 2006 (5273280 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = CHS1406 Fan Tray
Board Serial Number = AA123456
Board Part Number = 0106876A01B
FRU Programmer File ID = CHS1406R_FT_UpperFront.inf
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1406 Fan Tray
Product Part / Model# = TFT-F-1406
Product Version = Rev. 1.00
Product Serial Number = AA123456
FRU Programmer File ID = CHS1406R_FT_UpperFront.inf
Version = 1 · Version = 1 · Asset Tag =

FRU Information FRU Information and Sensor Data Records
Pigeon Point Shelf Manager Command Line Interpreter
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = CHS1406 Fan Tray
Board Serial Number = AA123456
Board Part Number = 0106877A01B
FRU Programmer File ID = CHS1406R_FT_UpperRear.inf
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1406 Fan Tray
Product Part / Model# = TFT-R-1406
Product Version = Rev. 1.00
Product Serial Number = AA123456
FRU Programmer File ID = CHS1406R_FT_UpperRear.inf
Pigeon Point Shelf Manager Command Line Interpreter
Board Info Area:
Language Code = 25

FRU Information and Sensor Data Records FRU Information
Mfg Date/Time = Jan 10 00:00:00 2006 (5273280 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = CHS1406 Fan Tray
Board Serial Number = AA123456
Board Part Number = 0106878A01B
FRU Programmer File ID = CHS1406R_FT_LowerFront.inf
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1406 Fan Tray
Product Part / Model# = BFT-F-1406
Product Version = Rev. 1.00
Product Serial Number = AA123456
FRU Programmer File ID = CHS1406R_FT_LowerFront.inf
There are nine fan trays in the AXP1600 shelf, six of them are located at the top of the shelf and three are located in the bottom. Looking at the shelf from the top; the location of the fan tray FRUs 1 through 6 looks like this:
Figure 2-3 Upper Fan Tray Locations, AXP1600

FRU Information FRU Information and Sensor Data Records
The bottom three fan trays are FTM 7 (left side) and FTM 8 (center), and FTM 9 (right side) looking at the shelf from the front.
Figure 2-4 Lower Fan Tray Locations, AXP1600
The FRU information for fan trays 1, 2 and 3 is the same (except serial numbers); similarly for fan trays 4, 5 and 6; and for fan trays 7, 8 and 9. This information follows:
Pigeon Point Shelf Manager Command Line Interpreter
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = CHS1600 Fan Tray
Board Serial Number = 1234567890
Board Part Number = 01-W2327F12A
FRU Programmer File ID = CHS1600R_FT_UpperFront.inf
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1600 Fan Tray
Bottom Front · Version = 1 · Version = 1

FRU Information and Sensor Data Records FRU Information
Product Part / Model# = TFT-F-1600
Product Version = Rev. 1.00
Product Serial Number = 1234567890
FRU Programmer File ID = CHS1600R_FT_UpperFront.inf
Pigeon Point Shelf Manager Command Line Interpreter
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = CHS1600 Fan Tray
Board Serial Number = 1234567890
Board Part Number = 01-W2328F12A
FRU Programmer File ID = CHS1600R_FT_UpperRear.inf
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1600 Fan Tray
Product Part / Model# = TFT-R-1600
Product Version = Rev. 1.00
Product Serial Number = 1234567890
FRU Programmer File ID = CHS1600R_FT_UpperRear.inf

E-Keying FRU Information and Sensor Data Records
Pigeon Point Shelf Manager Command Line Interpreter
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = CHS1600 Fan Tray
Board Serial Number = 1234567890
Board Part Number = 01-W2329F12A
FRU Programmer File ID = CHS1600R_FT_LowerFront.inf
Product Info Area:
Language Code = 25
Manufacturer Name = Motorola
Product Name = CHS1600 Fan Tray
Product Part / Model# = BFT-F-1600
Product Version = Rev. 1.00
Product Serial Number = 1234567890
FRU Programmer File ID = CHS1600R_FT_LowerFront.inf
The active (virtual) SAM does not have e-keyed backplane interfaces, and hence the FRU information for it does not contain a PICMG Point-to-Point Connectivity Record.
Version = 1 · Version = 1 · Asset Tag =

FRU Information and Sensor Data Records Power Configuration
The following table describes the power configuration for the Active SAM.
Table 2-24 SAM1000 Active Power Configuration
Dynamic power reconfiguration support No Possibility to change FRU power consumption without switching it off, according to AdvancedTCA
Dynamic power configuration No Are the power draw levels fixed or these may vary if additional components are hot inserted or onboard components’ power consumption is changing dynamically
Number of power draw levels 1 The amount of possible power levels, normally 1
Early power draw levels, Watt 5 Complete early power consumption including IPMC
Steady state power draw levels, Watt 5 Complete steady power consumption including IPMC
Transition from Early to Steady levels, sec
0 How long does board consumes early power. Early power is normally bigger than steady
The following table lists the discrete and analog sensors that reside on the Active SAM. The information in this section supports the SAM on both the AXP1406 and AXP1600 shelves. The AXP1600 FRU and sensor data is highlighted and/or marked for ease of use.
Rows that are highlighted in blue provide information for the additional sensors on the SAM1000 for the AXP1600.
Table 2-25 Active SAM1000 Sensor Overview
Sensor No. Sensor Name
What does it measure?
Status State of FRU Discrete Always
Status State of FRU Discrete Always
Status State of FRU Discrete Always
Status State of FRU Discrete Always
Status State of FRU Discrete Always
Status State of FRU Discrete Always
Item Value Meaning · Type of Measurement · Sensor Type Availability

Active SAM1000 Sensor Overview FRU Information and Sensor Data Records
Table 2-25 Active SAM1000 Sensor Overview (continued)
Sensor No. Sensor Name
What does it measure?
Status State of FRU Discrete Always
Status State of FRU Discrete Always
Status State of FRU Discrete Always
10 FRU9 HOT_SWAP Status State of FRU Discrete Always
Status State of SHM Discrete Always
12 IPMB LINK 1 Status State of IPMB link
13 IPMB LINK 2 Status State of IPMB link
14 IPMB LINK 3 Status State of IPMB link
15 IPMB LINK 4 Status State of IPMB link
16 IPMB LINK 5 Status State of IPMB link
17 IPMB LINK 6 Status State of IPMB link
18 IPMB LINK 7 Status State of IPMB link
19 IPMB LINK 8 Status State of IPMB link
20 IPMB LINK 9 Status State of IPMB link
21 IPMB LINK 10 Status State of IPMB link
22 IPMB LINK 11 Status State of IPMB link
23 IPMB LINK 12 Status State of IPMB link
24 IPMB LINK 13 Status State of IPMB link
25 IPMB LINK 14 Status State of IPMB link
26 IPMB LINK 15 Status State of IPMB link
27 IPMB LINK 16 Status State of IPMB link

FRU Information and Sensor Data Records Active SAM1000 Sensor Overview
Table 2-25 Active SAM1000 Sensor Overview (continued)
Sensor No. Sensor Name
What does it measure?
28 IPMB LINK 17 Status State of IPMB link
29 IPMB LINK 18 Status State of IPMB link
30 IPMB LINK 19 Status State of IPMB link
31 IPMB LINK 20 Status State of IPMB link
32 IPMB LINK 21 Status State of IPMB link
131 TELCO Alarms Status State of TELCO Alarms
132 BMC Watchdog Status State of BMC Watchdog on active SAM
133 SYSTEM EVENT Status State of PEF actions, system reconfigured events, etc.
141 FT 1 Fan 1 Fan Speed RPM of Fan 1 Analog Always
142 FT 1 Fan 2 Fan Speed RPM of Fan 2 Analog Always
143 FT 2 Fan 1 Fan Speed RPM of Fan 1 Analog Always
144 FT 2 Fan 2 Fan Speed RPM of Fan 2 Analog Always
145 FT 3 Fan 1 Fan Speed RPM of Fan 1 Analog Always
146 FT 3 Fan 2 Fan Speed RPM of Fan 2 Analog Always
147 FT 4 Fan 1 Fan Speed RPM of Fan 1 Analog Always
148 FT 4 Fan 2 Fan Speed RPM of Fan 2 Analog Always
149 FT 5 Fan 1 Fan Speed RPM of Fan 1 Analog Always
150 FT 5 Fan 2 Fan Speed RPM of Fan 2 Analog Always
151 FT 6 Fan 1 Fan Speed RPM of Fan 1 Analog Always
152 FT 6 Fan 2 Fan Speed RPM of Fan 2 Analog Always
153 FT 7 Fan 1 Fan Speed RPM of Fan 1 Analog Always
154 FT 7 Fan 2 Fan Speed RPM of Fan 2 Analog Always
155 FT 8 Fan 1 Fan Speed RPM of Fan 1 Analog Always
156 FT 8 Fan 2 Fan Speed RPM of Fan 2 Analog Always
157 FT 9 Fan 1 Fan Speed RPM of Fan 1 Analog Always
158 FT 9 Fan 2 Fan Speed RPM of Fan 2 Analog Always
171 FT 1 Fan 1 12 V Voltage Analog Always

Active SAM1000 Sensor Overview FRU Information and Sensor Data Records
Table 2-25 Active SAM1000 Sensor Overview (continued)
Sensor No. Sensor Name
What does it measure?
172 FT 1 Fan 1 VBias Voltage Analog Always
173 FT 1 Fan 2 12 V Voltage Analog Always
174 FT 1 Fan 2 VBias Voltage Analog Always
175 FT 2 Fan 1 12 V Voltage Analog Always
176 FT 2 Fan 1 VBias Voltage Analog Always
177 FT 2 Fan 2 12 V Voltage Analog Always
178 FT 2 Fan 2 VBias Voltage Analog Always
179 FT 3 Fan 1 12 V Voltage Analog Always
180 FT 3 Fan 1 VBias Voltage Analog Always
181 FT 3 Fan 2 12 V Voltage Analog Always
182 FT 3 Fan 2 VBias Voltage Analog Always
183 FT 4 Fan 1 12 V Voltage Analog Always
184 FT 4 Fan 1 VBias Voltage Analog Always
185 FT 4 Fan 2 12 V Voltage Analog Always
186 FT 4 Fan 2 VBias Voltage Analog Always
187 FT 5 Fan 1 12 V Voltage Analog Always
188 FT 5 Fan 1 VBias Voltage Analog Always
189 FT 5 Fan 2 12 V Voltage Analog Always
190 FT 5 Fan 2 VBias Voltage Analog Always
191 FT 6 Fan 1 12 V Voltage Analog Always
192 FT 6 Fan 1 VBias Voltage Analog Always
193 FT 6 Fan 2 12 V Voltage Analog Always
194 FT 6 Fan 2 VBias Voltage Analog Always
195 FT 7 Fan 1 12 V Voltage Analog Always
196 FT 7 Fan 1 VBias Voltage Analog Always
197 FT 7 Fan 2 12 V Voltage Analog Always
198 FT 7 Fan 2 VBias Voltage Analog Always
199 FT 8 Fan 1 12 V Voltage Analog Always
200 FT 8 Fan 1 VBias Voltage Analog Always
201 FT 8 Fan 2 12 V Voltage Analog Always
202 FT 8 Fan 2 VBias Voltage Analog Always
203 FT 9 Fan 1 12 V Voltage Analog Always
204 FT 9 Fan 1 VBias Voltage Analog Always
205 FT 9 Fan 2 12 V Voltage Analog Always
206 FT 9 Fan 2 VBias Voltage Analog Always
Type of Measurement · Sensor Type Availability

FRU Information and Sensor Data Records Active SAM1000 Sensor Overview
Table 2-25 Active SAM1000 Sensor Overview (continued)
Sensor No. Sensor Name
What does it measure?
220 Fan Tray 1 Status Fan Tray 1 Presence
221 Fan Tray 2 Status Fan Tray 2 Presence
222 Fan Tray 3 Status Fan Tray 3 Presence
223 Fan Tray 4 Status Fan Tray 4 Presence
224 Fan Tray 5 Status Fan Tray 5 Presence
225 Fan Tray 6 Status Fan Tray 6 Presence
226 Fan Tray 7 Status Fan Tray 7 Presence
227 Fan Tray 8 Status Fan Tray 8 Presence
228 Fan Tray 9 Status Fan Tray 9 Presence
230 FT 1 -48 V Fuse Status OEM-reserved Discrete Always
231 FT 2 -48 V Fuse Status OEM-reserved Discrete Always
232 FT 3 -48 V Fuse Status OEM-reserved Discrete Always
233 FT 4 -48 V Fuse Status OEM-reserved Discrete Always
234 FT 5 -48 V Fuse Status OEM-reserved Discrete Always
235 FT 6 -48 V Fuse Status OEM-reserved Discrete Always
236 FT 7 -48 V Fuse Status OEM-reserved Discrete Always
237 FT 8 -48 V Fuse Status OEM-reserved Discrete Always
238 FT 9 -48 V Fuse Status OEM-reserved Discrete Always

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
The Active SAM at IPMB address 0x20 presents the following analog sensors:
All fan sensors are exposed by the Active SAM.
z Fan Speed Sensors
z Fan Voltage Sensors
The following tables describe the analog fan speed sensors available on the Active SAM.
Table 2-26 Sensor No. 141 (0x8D) FT 1 Fan 1
Sensor Name FT 1 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-27 Sensor No. 142 (0x8E) FT 1 Fan 2
Sensor Name FT 1 Fan 2
Sensor Type 0x04 Fan Speed
0x00 Sensor Owner LUN

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-27 Sensor No. 142 (0x8E) FT 1 Fan 2 (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-28 Sensor No. 143 (0x8F) FT 2 Fan 1
Sensor Name FT 2 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-29 Sensor No. 144 (0x90) FT2 Fan 2
Sensor Name FT 2 Fan 2
Sensor Type 0x04 Fan Speed

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-29 Sensor No. 144 (0x90) FT2 Fan 2 (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-30 Sensor No. 145 (0x91) FT 3 Fan 1
Sensor Name FT 3 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-31 Sensor No. 146 (0x92) FT 3 Fan 2
Raw Value/Description Feature Interpreted Value
Sensor Name FT 3 Fan 2
Sensor Type 0x04 Fan Speed

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-31 Sensor No. 146 (0x92) FT 3 Fan 2 (continued)
Raw Value/Description Feature Interpreted Value
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-32 Sensor No. 147 (0x93) FT 4 Fan 1
Sensor Name FT 4 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-33 Sensor No. 148 (0x94) FT 4 Fan 2
Sensor Name FT 4 Fan 2
Sensor Type 0x04 Fan Speed

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-33 Sensor No. 148 (0x94) FT 4 Fan 2 (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-34 Sensor No. 149 (0x95) FT 5 Fan 1
Sensor Name FT 5 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-35 Sensor No. 150 (0x96) FT 5 Fan 2
Sensor Name FT 5 Fan 2
Sensor Type 0x04 Fan Speed

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-35 Sensor No. 150 (0x96) FT 5 Fan 2 (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-36 Sensor No. 151 (0x97) FT 6 Fan 1
Sensor Name FT 6 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x0 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-37 Sensor No. 152 (0x98) FT 6 Fan 2
Raw Value/Description Feature Interpreted Value
Sensor Name FT 6 Fan 2
Sensor Type 0x04 Fan Speed

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-37 Sensor No. 152 (0x98) FT 6 Fan 2 (continued)
Raw Value/Description Feature Interpreted Value
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x0 Lower Critical Threshold is Readable
Lower critical threshold 0x23 1190 RPM
Table 2-38 Sensor No. 153 (0x99) FT 7 Fan 1
Sensor Name FT 7 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x83 5895 RPM
Table 2-39 Sensor No. 154 (0x9A) FT 7 Fan 2
Sensor Name FT 7 Fan 2
Sensor Type 0x04 Fan Speed

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-39 Sensor No. 154 (0x9A) FT 7 Fan 2 (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x83 5895 RPM
Table 2-40 Sensor No. 155 (0x9B) FT 8 Fan 1
Sensor Name FT 8 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x83 5895 RPM
Table 2-41 Sensor No. 156 (0x9C) FT 8 Fan 2
Sensor Name FT 8 Fan 2
Sensor Type 0x04 Fan Speed

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-41 Sensor No. 156 (0x9C) FT 8 Fan 2 (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x83 5895 RPM
Two additional Fan Speed sensors support the SAM used in the AXP1600 shelf.
Table 2-42 Sensor No. 157 (0x9D) FT 9 Fan 1, AXP1600
Sensor Name FT 9 Fan 1
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x83 5895 RPM

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-43 Sensor No. 158 (0x9E) FT 9 Fan 2, AXP1600
Sensor Name FT 9 Fan 2
Sensor Type 0x04 Fan Speed
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x02, 0x00 Lower Critical Threshold is Readable
Lower critical threshold 0x83 5895 RPM
The following tables describe the analog fan voltage sensors available on the Active SAM.
Table 2-44 Sensor No. 171 (0xAB) FT 1 Fan 1 12 V
Sensor Name FT 1 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-44 Sensor No. 171 (0xAB) FT 1 Fan 1 12 V (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-45 Sensor No. 172 (0xAC) FT 1 Fan 1 VBias
Sensor Name FT 1 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-46 Sensor No. 173 (0xAD) FT 1 Fan 2 12 V
Sensor Name FT 1 Fan 2 12 V
Sensor Type 0x02 Voltage

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-46 Sensor No. 173 (0xAD) FT 1 Fan 2 12 V (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-47 Sensor No. 174 (0xAE) FT 1 Fan 2 VBias
Sensor Name FT 1 Fan 2 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-48 Sensor No. 175 (0xAF) FT 2 Fan 1 12 V
Sensor Name FT 2 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-49 Sensor No. 176 (0xB0) FT 2 Fan 1 VBias
Sensor Name FT 2 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-49 Sensor No. 176 (0xB0) FT 2 Fan 1 VBias (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-50 Sensor No. 177 (0xB1) FT 2 Fan 2 12 V
Sensor Name FT 2 Fan 2 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-51 Sensor No. 178 (0xB2) FT 2 Fan 2 VBias
Sensor Name FT 2 Fan 2 VBias
Sensor Type 0x02 Voltage

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-51 Sensor No. 178 (0xB2) FT 2 Fan 2 VBias (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-52 Sensor No. 179 (0xB3) FT 3 Fan 1 12 V
Sensor Name FT 3 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-53 Sensor No. 180 (0xB4) FT 3 Fan 1 VBias
Sensor Name FT 3 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-54 Sensor No. 181 (0xB5) FT 3 Fan 2 12 V
Sensor Name FT 3 Fan 2 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-54 Sensor No. 181 (0xB5) FT 3 Fan 2 12 V (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-55 Sensor No. 182 (0xB6) FT 3 Fan 2 VBias
Sensor Name FT 3 Fan 2 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-56 Sensor No. 183 (0xB7) FT 4 Fan 1 12 V
Sensor Name FT 4 Fan 1 12 V
Sensor Type 0x02 Voltage

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-56 Sensor No. 183 (0xB7) FT 4 Fan 1 12 V (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-57 Sensor No. 184 (0xB8) FT 4 Fan 1 VBias
Sensor Name FT 4 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-58 Sensor No. 185 (0xB9) FT 4 Fan 2 12 V
Sensor Name FT 4 Fan 2 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-59 Sensor No. 186 (0xBA) FT 4 Fan 2 VBias
Sensor Name FT 4 Fan 2 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-59 Sensor No. 186 (0xBA) FT 4 Fan 2 VBias (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-60 Sensor No. 187 (0xBB) FT 5 Fan 1 12 V
Sensor Name FT 5 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-61 Sensor No. 188 (0xBC) FT 5 Fan 1 VBias
Sensor Name FT 5 Fan 1 VBias
Sensor Type 0x02 Voltage

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-61 Sensor No. 188 (0xBC) FT 5 Fan 1 VBias (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-62 Sensor No. 189 (0xBD) FT 5 Fan 2 12 V
Sensor Name FT 5 Fan 2 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-63 Sensor No. 190 (0xBE) FT 5 Fan 2 VBias
Sensor Name FT 5 Fan 2 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-64 Sensor No. 191 (0xBF) FT 6 Fan 1 12 V
Sensor Name FT 6 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-64 Sensor No. 191 (0xBF) FT 6 Fan 1 12 V (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-65 Sensor No. 192 (0xC0) FT 6 Fan 1 VBias
Sensor Name FT 6 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-66 Sensor No. 193 (0xC1) FT 6 Fan 2 12 V
Sensor Name FT 6 Fan 2 12 V
Sensor Type 0x02 Voltage

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-66 Sensor No. 193 (0xC1) FT 6 Fan 2 12 V (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-67 Sensor No. 194 (0xC2) FT 6 Fan 2 VBias
Sensor Name FT 6 Fan 2 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-68 Sensor No. 195 (0xC3) FT 7 Fan 1 +12V
Sensor Name FT 7 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-69 Sensor No. 196 (0xC4) FT 7 Fan 1 VBias
Sensor Name FT 7 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-69 Sensor No. 196 (0xC4) FT 7 Fan 1 VBias (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-70 Sensor No. 197 (0xC5) FT 7 Fan 2 12 V
Sensor Name FT 7 Fan 2 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-71 Sensor No. 198 (0xC6) FT 7 Fan 2 VBias
Sensor Name FT 7 Fan 2 VBias
Sensor Type 0x02 Voltage

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-71 Sensor No. 198 (0xC6) FT 7 Fan 2 VBias (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-72 Sensor No. 199 (0xC7) FT 8 Fan 1 12 V
Sensor Name FT 8 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-73 Sensor No. 200 (0xC8) FT 8 Fan 1 VBias
Sensor Name FT 8 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-74 Sensor No. 201 (0xC9) FT 8 Fan 2 12 V
Sensor Name FT 8 Fan 2 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-74 Sensor No. 201 (0xC9) FT 8 Fan 2 12 V (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-75 Sensor No. 202 (0xCA) FT 8 Fan 2 VBias
Sensor Name FT 8 Fan 2 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Additional Fan Voltage sensors support the SAM used in the AXP1600 shelf.

FRU Information and Sensor Data Records Active SAM1000 Analog Sensors
Table 2-76 Sensor No. 203 (0xCB) FT 9 Fan 1 12 V, AXP1600
Sensor Name FT 9 Fan 1 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-77 Sensor No. 204 (0xCC) FT 9 Fan 1 VBias, AXP1600
Sensor Name FT 9 Fan 1 VBias
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable

Active SAM1000 Analog Sensors FRU Information and Sensor Data Records
Table 2-77 Sensor No. 204 (0xCC) FT 9 Fan 1 VBias, AXP1600 (continued)
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
Table 2-78 Sensor No. 205 (0xCD) FT 9 Fan 2 12 V, AXP1600
Sensor Name FT 9 Fan 2 12 V
Sensor Type 0x02 Voltage
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x50, 0x4c (6.88, 6.536) Volts
Upper critical and non- recoverable thresholds
0x9F, 0xA0 (13.674, 13.76) Volts
Table 2-79 Sensor No. 206 (0xCE) FT 9 Fan 2 VBias, AXP1600
Sensor Name FT 9 Fan 2 VBias
Sensor Type 0x02 Voltage

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-79 Sensor No. 206 (0xCE) FT 9 Fan 2 VBias, AXP1600 (continued)
Threshold access support Readable/Settable
Readable and Settable threshold mask (bytes 19, 20)
0x36, 0x00 Upper and Lower Critical and Non-recoverable Thresholds are Readable
Lower critical and non- recoverable thresholds
0x73, 0x71 (9.89, 9.718) Volts
Upper critical and non- recoverable thresholds
0x87, 0xA5 (11.61, 14.19) Volts
The active shelf managers at IPMB address 0x20 present the following discrete sensors:
z Hot Swap Sensors
z Shm Fault Event Sensor
z IPMB Link Sensor
z Telco Alarm Sensor
z BMC Watchdog Sensor
z Fan Tray Presence Sensor
z Fan Tray -48 V Fuse Sensor
The following tables describe the discrete sensors available on the active SAM.
Hysteresis support No · Reading Type Unsigned · z System Event

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
The following table describes the discrete hot swap sensors available on the Active SAM.
Table 2-80 Sensor No. 0 (0x00) FRU 0 HOT_SWAP
Sensor Name FRU 0 HOT_SWAP
Type of Measurement Hot Swap State of Main FRU
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
Table 2-81 Sensor No. 2 (0x02) FRU 1 HOT_SWAP
Sensor Name FRU 1 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 1
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-81 Sensor No. 2 (0x02) FRU 1 HOT_SWAP (continued)
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
Table 2-82 Sensor No. 3 (0x03) FRU 2 HOT_SWAP
Sensor Name FRU 2 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 2
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
Table 2-83 Sensor No. 4 (0x04) FRU 3 HOT_SWAP
Sensor Name FRU 3 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 3
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-83 Sensor No. 4 (0x04) FRU 3 HOT_SWAP (continued)
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
Table 2-84 Sensor No. 5 (0x05) FRU 4 HOT_SWAP
Sensor Name FRU 4 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 4
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
Table 2-85 Sensor No. 6 (0x06) FRU 5 HOT_SWAP
Sensor Name FRU 5 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 5
Event/Reading Type 0x6F Sensor-specific

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-85 Sensor No. 6 (0x06) FRU 5 HOT_SWAP (continued)
Sensor Type 0xF0 Hot Swap
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
Table 2-86 Sensor No. 7 (0x07) FRU 6 HOT_SWAP
Sensor Name FRU 6 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 6
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-87 Sensor No. 8 (0x08) FRU 7 HOT_SWAP
Sensor Name FRU 7 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 7
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
Table 2-88 Sensor No. 9 (0x09) FRU 8 HOT_SWAP
Sensor Name FRU 8 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 8
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
A FRU 9 Hot Swap sensor supports the SAM used in the AXP1600 shelf.
Table 2-89 Sensor No. 10 (0x0A) FRU 9 HOT_SWAP, AXP1600
Sensor Name FRU 8 HOT_SWAP
Type of Measurement Hot Swap State of Fan Tray 8
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF0 Hot Swap
Assertion Event Mask (bytes 15,16) 0xFF, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
The following table describes the discrete Shm Fault Event sensor available on the Active SAM.
Table 2-90 Sensor No. 11 (0x20) Fault Event Sensor
Sensor Name Shm Fault Event
Type of Measurement Status of various classes of software discovered faults in the Shm
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xDE OEM-reserved

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-90 Sensor No. 11 (0x20) Fault Event Sensor (continued)
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0xFE 0x01
Deassertion Event Mask (bytes 17,18) 0xFE 0x01
Discrete Reading Mask (bytes 19, 20) 0xFE 0x01
Reading Definition According to Motorola XXX
The following table describes the discrete IPMB link sensors available on the Active SAM.
Table 2-91 Sensor No. 12 (0x0B) IPMB LINK 1
Sensor Name IPMB LINK 1
Type of Measurement IPMB Link 1 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-92 Sensor No. 13 (0x0C) IPMB LINK 2
Sensor Name IPMB LINK 2
Type of Measurement IPMB Link 2 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-93 Sensor No. 14 (0x0D) IPMB LINK 3
Sensor Name IPMB LINK 3
Type of Measurement IPMB Link 3 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-93 Sensor No. 14 (0x0D) IPMB LINK 3 (continued)
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-94 Sensor No. 15 (0x0E) IPMB LINK 4
Sensor Name IPMB LINK 4
Type of Measurement IPMB Link 4 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-95 Sensor No. 16 (0x0F) IPMB LINK 5
Sensor Name IPMB LINK 5
Type of Measurement IPMB Link 5 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-95 Sensor No. 16 (0x0F) IPMB LINK 5 (continued)
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-96 Sensor No. 17 (0x10) IPMB LINK 6
Sensor Name IPMB LINK 6
Type of Measurement IPMB Link 6 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-97 Sensor No. 18 (0x11) IPMB LINK 7
Sensor Name IPMB LINK 7
Type of Measurement IPMB Link 7 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-98 Sensor No. 19 (0x12) IPMB LINK 8
Sensor Name IPMB LINK 8
Type of Measurement IPMB Link 8 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-98 Sensor No. 19 (0x12) IPMB LINK 8 (continued)
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-99 Sensor No. 20 (0x14) IPMB LINK 9
Sensor Name IPMB LINK 9
Type of Measurement IPMB Link 9 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-100 Sensor No. 21 (0x14) IPMB LINK 10
Sensor Name IPMB LINK 10
Type of Measurement IPMB Link 10 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-100 Sensor No. 21 (0x14) IPMB LINK 10 (continued)
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-101 Sensor No. 22 (0x15) IPMB LINK 11
Sensor Name IPMB LINK 11
Type of Measurement IPMB Link 11 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-102 Sensor No. 23 (0x16) IPMB LINK 12
Sensor Name IPMB LINK 12
Type of Measurement IPMB Link 12 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-103 Sensor No. 24 (0x17) IPMB LINK 13
Sensor Name IPMB LINK 13
Type of Measurement IPMB Link 13 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-103 Sensor No. 24 (0x17) IPMB LINK 13 (continued)
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-104 Sensor No. 25 (0x18) IPMB LINK 14
Sensor Name IPMB LINK 14
Type of Measurement IPMB Link 14 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Additional IPMB LINK sensors support the SAM used in the AXP1600 shelf.

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-105 Sensor No. 26 (0x19) IPMB LINK 15, AXP1600
Sensor Name IPMB LINK 15
Type of Measurement IPMB Link 14 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-106 Sensor No. 27 (0x1A) IPMB LINK 16, AXP1600
Sensor Name IPMB LINK 16
Type of Measurement IPMB Link 14 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-106 Sensor No. 27 (0x1A) IPMB LINK 16, AXP1600 (continued)
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-107 Sensor No. 28 (0x1B) IPMB LINK 17
Sensor Name IPMB LINK 17
Type of Measurement IPMB Link 17 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-108 Sensor No. 29 (0x1C) IPMB LINK 18, AXP1600
Sensor Name IPMB LINK 18
Type of Measurement IPMB Link 17 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-108 Sensor No. 29 (0x1C) IPMB LINK 18, AXP1600 (continued)
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-109 Sensor No. 30 (0x1D) IPMB LINK 19, AXP1600
Sensor Name IPMB LINK 19
Type of Measurement IPMB Link 17 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-110 Sensor No. 31 (0x1E) IPMB LINK 20, AXP1600
Sensor Name IPMB LINK 20
Type of Measurement IPMB Link 17 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Table 2-111 Sensor No. 32 (0x1F) IPMB LINK 21, AXP1600
Sensor Name IPMB LINK 21
Type of Measurement IPMB Link 17 State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Entity ID 0xF0 PICMG Shelf Management Controller

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-111 Sensor No. 32 (0x1F) IPMB LINK 21, AXP1600 (continued)
Assertion Event Mask (bytes 15,16) 0x0F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
The following table describes the discrete Telco alarm sensor available on the Active SAM. Further information on this sensor can be found at Telco Alarms (Pigeon Point OEM) on page 137.
Table 2-112 Sensor No. 131 (0x83) TELCO Alarms
Sensor Name TELCO Alarms
Type of Measurement State of the TELCO Alarms
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xDF OEM-reserved
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x00, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x07, 0x00 OEM States
Reading Definition According to Pigeon Point

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
The following table describes the discrete BMC Watchdog sensor available on the Active SAM.
Table 2-113 Sensor No. 132 (0x84) BMC Watchdog
Sensor Name BMC Watchdog
Type of Measurement State of the BMC Watchdog on the Active SAM
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x23 IPMI Watchdog 2
Entity ID 0xF0 PICMG Shelf Management Controller
Assertion Event Mask (bytes 15,16) 0x0F, 0x01
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x0F, 0x01 Supports 5 States
Reading Definition According to IPMI 1.5
The following table describes the discrete system event sensor available on the Active SAM.
Table 2-114 Sensor No. 133 (0x85) SYSTEM EVENT
Sensor Name System Event
Type of Measurement Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x12 System Event
Entity ID 0xF0 PICMG Shelf Management Controller

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-114 Sensor No. 133 (0x85) SYSTEM EVENT (continued)
Assertion Event Mask (bytes 15,16) 0x1F, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x1F, 0x00 Supports 5 Successive States
Reading Definition According to IPMI 1.5
The following table describes the discrete fan tray presence sensor available on the Active SAM.
Table 2-115 Sensor No. 220 (0xDC) Fan Tray 1
Sensor Name Fan Tray 1
Type of Measurement Fan Tray 1 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x1E 0x1E
Assertion Event Mask(bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-116 Sensor No. 221 (0xDD) Fan Tray 2
Sensor Name Fan Tray 2
Type of Measurement Fan Tray 2 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x1E 0x1E
Assertion Event Mask(bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
Table 2-117 Sensor No. 222 (0xDE) Fan Tray 3
Sensor Name Fan Tray 3
Type of Measurement Fan Tray 3 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x1E 0x1E
Assertion Event Mask(bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-118 Sensor No. 223 (0xDF) Fan Tray 4
Sensor Name Fan Tray 4
Type of Measurement Fan Tray 4 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x1E 0x1E
Assertion Event Mask(bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
Table 2-119 Sensor No. 224 (0xE0) Fan Tray 5
Sensor Name Fan Tray 5
Type of Measurement Fan Tray 5 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x1E 0x1E
Assertion Event Mask(bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-120 Sensor No. 225 (0xE1) Fan Tray 6
Sensor Name Fan Tray 6
Type of Measurement Fan Tray 6 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x1E 0x1E
Assertion Event Mask(bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
Table 2-121 Sensor No. 226 (0xE2) Fan Tray 7
Sensor Name Fan Tray 7
Type of Measurement Fan Tray 7 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Entity ID 0x1E 0x1E
Assertion Event Mask(bytes 15,16) 0x03, 0x00
Deassertion Event Mask(bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-122 Sensor No. 227 (0xE3) Fan Tray 8
Sensor Name Fan Tray 8
Type of Measurement Fan Tray 8 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
An additional Fan Tray Presence sensor supports the SAM used in the AXP1600 shelf.
Table 2-123 Sensor No. 228 (0xE4) Fan Tray 9, AXP1600
Sensor Name Fan Tray 9
Type of Measurement Fan Tray 8 Presence
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-123 Sensor No. 228 (0xE4) Fan Tray 9, AXP1600 (continued)
Assertion Event Mask (bytes 15,16) 0x03, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
The following tables describes the discrete fan tray -48 V fuse sensors available on the Active SAM. For further information on these sensors, refer to FT -48 V Fuse (Emerson OEM) on page 139.
Table 2-124 Sensor No. 230 (0xE6) FT 1 -48 V Fuse
Sensor Name FT 1 -48V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-125 Sensor No. 231 (0xE7) FT 2 -48 V Fuse
Sensor Name FT 2 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point
Table 2-126 Sensor No. 233 (0xE9) FT 4 -48 V Fuse
Sensor Name FT 4 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-127 Sensor No. 232 (0xE8) FT 3 -48 V Fuse
Sensor Name FT 3 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point
Table 2-128 Sensor No. 234 (0xEA) FT 5 -48 V Fuse
Sensor Name FT 5 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point

FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
Table 2-129 Sensor No. 235 (0xEB) FT 6 -48 V Fuse
Sensor Name FT 6 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point
Table 2-130 Sensor No. 236 (0xEC) FT 7 -48 V Fuse
Sensor Name FT 7 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point

SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
Table 2-131 Sensor No. 237 (0xED) FT 8 -48 V Fuse
Sensor Name FT 8 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point
An additional -48 V Fuse sensor supports the SAM used in the AXP1600 shelf.
Table 2-132 Sensor No. 238 (0xEE) FT9 -48 V Fuse, AXP1600
Sensor Name FT 9 -48 V Fuse
Type of Measurement State of Fuse
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved

FRU Information and Sensor Data Records Power Entry Module Sensor Data Records
Table 2-132 Sensor No. 238 (0xEE) FT9 -48 V Fuse, AXP1600 (continued)
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x00, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to Pigeon Point
This section describes in detail all available IPMI sensors of the Power Entry Module.
There are two PEMs; one at IPMB address 0x66 and another at IPMB address 0x68. The main FRU (FRU 0) contains the FRU information of the PEM and it is the same for both PEMs (except for the serial number). FRU 1 contains the FRU information that the Active SAM caches as FRU 254 of IPMB address 0x20.
The FRU 0 information in a PEM1000 is represented in the next table.
Pigeon Point Shelf Manager Command Line Interpreter
Board Info Area:
Language Code = 25
Mfg Date/Time = Jan 1 00:00:00 2006 (5260320 minutes since 1996)
Board Manufacturer = Motorola
Board Product Name = PEM1000
Board Serial Number = 1234567890
Board Part Number = 01-W2330F11A
FRU Programmer File ID = PEM1000R.inf
Product Info Area:
Language Code = 25
Version = 1 · Version = 1

E-Keying FRU Information and Sensor Data Records
Manufacturer Name = Motorola
Product Name = AXP Power Entry Module
Product Part / Model# = PEM1000
Product Version = Rev. 01
Product Serial Number = 1234567890
FRU Programmer File ID = PEM1000R.inf
The Power Entry Module does not have e-keyed backplane interfaces, and as a result the FRU information for the PEM does not contain a PICMG Point-to-Point Connectivity Record.
The next table describes the power configuration for the PEMs.
Table 2-133 Power Configuration for PEMs
Dynamic power reconfiguration support No Possibility to change FRU power consumption without switching it off, according to AdvancedTCA
Dynamic power configuration No Are the power draw levels fixed or these may vary if additional components are hot inserted or onboard component power consumption is changing dynamically
Number of power draw levels 1 The amount of possible power levels, normally 1
Early power draw levels, watt 0.1 Complete early power level including IPMC
Steady state power draw levels, watt 0.1 Complete steady power consumption including IPMC
Transition from early to steady levels in seconds 0 How long does board consume early power. Early power is normally bigger than steady power
Asset Tag = · Item Value Description

FRU Information and Sensor Data Records Power Entry Module Sensor Overview
The following table lists all IPMI sensors available on the Power Entry Module.
Table 2-134 IPMI Sensors on the PEM
Sensor No. Sensor Name
What does it measure?
0 Hot Swap Status State of FRU Discrete Always
1 IPMB Physical Status State of IPMB link Discrete Always
2 +3.3 V Voltage Analog Always
3 +8 V Backup Out Voltage Analog Always
4 +12 V Backplane Voltage Analog Always
5 CB 1 Status Circuit Breaker fuse state
6 CB 2 Status Circuit Breaker fuse state
7 CB 3 Status Circuit Breaker fuse state
8 CB 4 Status Circuit Breaker fuse state
9 CB 5 Status Circuit Breaker fuse state
10 DS75 Temp Temperature Analog Always
11 +48.0 V FEED Voltage Analog Always
12 +7.5 V PEM Voltage Analog Always
13 +8 V PEM Feed 2 Voltage Analog Always
14 +12 V Current Current Analog Always
15 +8 V PEM Feed 1 Voltage Analog Always
The analog sensors available on the PEM can be divided into the following four categories:

Power Entry Module Analog Sensors FRU Information and Sensor Data Records
The following sensors measure voltages of the PEM.
Table 2-135 Sensor No. 2 +3.3 V
Sensor Name +3.3 V
Sensor Type 0x02 Voltage
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Lower Non-Critical, Critical and Non-Recoverable thresholds
0xD8, 0xD4, 0xD1 (3.1104, 2.0528, 3.0096) Volts
Upper Non-Critical, Critical and Non-Recoverable thresholds
0xF4, 0xF7, 0xFA (3.5136, 3.5568, 3.6) Volts
Table 2-136 Sensor No. 3 +8 V
Sensor Name +8 V Backup Out
Sensor Type 0x02 Voltage
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable

FRU Information and Sensor Data Records Power Entry Module Analog Sensors
Table 2-136 Sensor No. 3 +8 V (continued)
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Lower Non-Critical, Critical and Non-Recoverable thresholds
0x87, 0x7D, 0x74 (7.02, 6.5, 6.032) Volts
Upper Non-Critical, Critical and Non-Recoverable thresholds
0xAE, 0xB7, 0xC1 (0.048, 9.516, 10.036) Volts
Table 2-137 Sensor No. 4 +12 V Backplane
Sensor Name +12 V Backplane
Sensor Type 0x02 Voltage
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Lower Non-Critical, Critical and Non-Recoverable thresholds
0xD4, 0xCA, 0xC1 (11.024, 10.504, 10.036) Volts
Upper Non-Critical, Critical and Non-Recoverable thresholds
0xFA, 0xFF, 0xFF (13, 13.26, 13.26) Volts
Table 2-138 Sensor No. 11 +48.0 V Feed
Sensor Name +48.0 V FEED
Sensor Type 0x02 Voltage

Power Entry Module Analog Sensors FRU Information and Sensor Data Records
Table 2-138 Sensor No. 11 +48.0 V Feed (continued)
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Lower Non-Critical, Critical and Non-Recoverable thresholds
0x86, 0x7A, 0x73 (42.076, 38.308, 36.11) Volts
Upper Non-Critical, Critical and Non-Recoverable thresholds
0xE6, 0xEF, 0xF3 (72.22, 75.046, 76.302) Volts
Table 2-139 Sensor No. 12 +7.5 V PEM
Sensor Name +7.5 V PEM
Sensor Type 0x02 Voltage
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Lower Non-Critical, Critical and Non-Recoverable thresholds
0x7D, 0x74, 0x6A (6.5, 6.032, 5.512) Volts
Upper Non-Critical, Critical and Non-Recoverable thresholds
0xA4, 0xAE, 0xB7 (8.528, 9.048, 9.516) Volts

FRU Information and Sensor Data Records Power Entry Module Analog Sensors
Table 2-140 Sensor No. 13 +8 V PEM Feed 2
Sensor Name +8 V PEM Feed 2
Sensor Type 0x02 Voltage
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Lower Non-Critical, Critical and Non-Recoverable thresholds
0x87, 0x7D, 0x74 (7.02, 6.5, 6.032) Volts
Upper Non-Critical, Critical and Non-Recoverable thresholds
0xAE, 0xB7, 0xC1 (9.048, 9.516, 10.036) Volts
Table 2-141 Sensor No. 15 +8 V PEM Feed 1
Sensor Name +8 V PEM Feed 1
Sensor Type 0x02 Voltage
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable

Power Entry Module Analog Sensors FRU Information and Sensor Data Records
Table 2-141 Sensor No. 15 +8 V PEM Feed 1 (continued)
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x3F, 0x3F Upper and Lower Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Lower Non-Critical, Critical and Non-Recoverable thresholds
0x87, 0x7D, 0x74 (7.02, 6.5, 6.032) Volts
Upper Non-Critical, Critical and Non-Recoverable thresholds
0xAE, 0xB7, 0xC1 (9.048, 9.516, 10.036) Volts
The following table describes the sensor that measures the +12V current on the PEM.
Table 2-142 Sensor No. 14 +12 V Current
Sensor Name +12 V Current
Sensor Type 0x03 Current
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x38, 0x38 Upper Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Upper Non-Critical, Critical and Non-Recoverable thresholds
0x4A, 0x4E, 0x52 (9.028, 9.516, 10.004) Amps

FRU Information and Sensor Data Records Power Entry Module Discrete Sensors
The following tables describe the temperature sensors available on the PEMs.
Table 2-143 Sensor No. 10 DS75 Temp
Sensor Name DS75 Temp
Sensor Type 0x01 Temperature
Entity ID 0x0A Power Supply
Threshold access support Readable/Settable
Readable threshold mask, Settable threshold mask (bytes 19, 20)
0x38, 0x38 Upper Non-Critical, Critical and Non-Recoverable Thresholds are Readable and Settable
Upper Non-Critical, Critical and Non-Recoverable thresholds
0x28, 0x3C, 0x50 (40, 60, 80) Centigrades
The following tables describe these discrete sensors available on the PEM:
z Hot Swap Sensor
z IPMB Link Sensor
z Circuit Breaker State Sensors
The following table describes the discrete hot swap sensor available on the PEM.
Table 2-144 Sensor #0, Hot Swap
Sensor Name Hot Swap
Type of Measurement Hot Swap State
Event/Reading Type 0x6F Sensor-specific

Power Entry Module Discrete Sensors FRU Information and Sensor Data Records
Table 2-144 Sensor #0, Hot Swap (continued)
Sensor Type 0xF0 Hot Swap
Entity ID 0x0A Power Supply
Assertion Event Mask (byte 15, 16) 0xFF, 0x00
Deassertion Event Mask (byte 17, 18) 0x00, 0x00
Discrete Reading Mask (byte 19, 20) 0xFF, 0x00 Supports 8 Successive States
Reading Definition According to PICMG 3.0
The following table describes the IPMB link sensor on the PEMs.
Table 2-145 Sensor #1, IPMB Physical
Sensor Name IPMB Physical
Type of Measurement IPMB Link State
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Assertion Event Mask (byte 15, 16) 0x0F, 0x00
Deassertion Event Mask (byte 17, 18) 0x00, 0x00
Discrete Reading Mask (byte 19, 20) 0x0F, 0x00 Supports 4 Successive States
Reading Definition According to PICMG 3.0
Entity ID 0x0A

FRU Information and Sensor Data Records Circuit Breaker State Sensors
The following tables describe the OEM circuit breaker state sensors available on the PEM.
Table 2-146 Sensor #5, CB 1
Sensor Name CB 1
Type of Measurement Monitors if the circuit breaker has been opened.l
Event/Reading Type 0x03 Digital Discrete
Sensor Type 0xC0 OEM-reserved
Entity ID 0x0A Power Supply
Assertion Event Mask (byte 15, 16) 0x02, 0x00
Deassertion Event Mask (byte 17, 18) 0x02, 0x00
Discrete Reading Mask (byte 19, 20) 0x03, 0x00 Supports 2 States
Reading Definition According to Pigeon Point
Table 2-147 Sensor #6 CB 2
Sensor Name CB 2
Type of Measurement Monitors if the circuit breaker has been opened.l
Event/Reading Type 0x03 Digital Discrete
Sensor Type 0xC0 OEM-reserved
Entity ID 0x0A Power Supply
Event Message Control Discrete State Event Enable/Disable
Entity Instance

Circuit Breaker State Sensors FRU Information and Sensor Data Records
Table 2-147 Sensor #6 CB 2 (continued)
Assertion Event Mask (byte 15, 16) 0x02, 0x00 State Deasserted State Asserted
Deassertion Event Mask (byte 17, 18) 0x02, 0x00 State Deasserted State Asserted
Discrete Reading Mask (byte 19, 20) 0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
Table 2-148 Sensor No. 7 CB 3
Sensor Name CB 3
Type of Measurement Monitors if the Circuit Breaker has been opened.
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Entity ID 0x0A Power Supply
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x02, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 States
Reading Definition According to Pigeon Point
Table 2-149 Sensor No. 8 CB 4
Sensor Name CB 4
Type of Measurement Monitors if the Circuit Breaker has been opened.
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved

FRU Information and Sensor Data Records Circuit Breaker State Sensors
Table 2-149 Sensor No. 8 CB 4 (continued)
Entity ID 0x0A Power Supply
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x02, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 States
Reading Definition According to Pigeon Point
Table 2-150 Sensor No. 9 CB 5
Sensor Name CB 5
Type of Measurement Monitors if the Circuit Breaker has been opened.
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0xC0 OEM-reserved
Entity ID 0x0A Power Supply
Assertion Event Mask (bytes 15,16) 0x02, 0x00
Deassertion Event Mask (bytes 17,18) 0x02, 0x00
Discrete Reading Mask (bytes 19, 20) 0x03, 0x00 Supports 2 States
Reading Definition According to Pigeon Point

3.1 OEM Sensors
This section describes the various OEM sensors provided by Emerson and Pigeon Point Systems that are located on the SAM.
z Telco Alarms (Pigeon Point OEM)
z AXP Backplane ID (Emerson OEM)
z POST Results (Emerson OEM)
z Shelf FRU Info (Emerson OEM)
z FT -48 V Fuse (Emerson OEM)
z Shm Fault Event (Emerson OEM)
The ShM implements the alarm generation mechanism as part of the platform event filtering (PEF) framework. An OEM action in PEF is implemented as alarm generation. The ShM implements the alarm sensor in its own sensor space. The sensor type for this sensor is OEM specific, currently chosen to be DFh. The sensor is a discrete sensor with three states:
z State 0 reflects the presence of the Critical alarm
z State 1 reflects the presence of the Major alarm
z State 2 reflects the presence of the Minor alarm
Changes in the states of this sensor may be mapped to events using regular IPMI mechanisms.
Subsequently, platform event filtering may be used to specify actions, such as chassis reset or power cycle, that should be invoked for these events, or alerts to be sent to remote destinations (including the System Manager).
The alarm sensor is recorded in the device SDR repository maintained by the ShM. The command Re-Arm Sensor Events can be used by the ShM to clear active Major and Minor alarms.
The ShM tracks the current state of alarms and the alarm cutoff input line and modifies the state of alarm LEDs accordingly. When the alarm cutoff signal gets activated, the ShM stops generating the alarms to the external output, but maintains the alarm state internally. The alarm LED(s) is (are) left blinking during that time. When the alarm cutoff signal gets deactivated, the state of external outputs and LEDs is restored according to the current state of the alarms (Minor and Major alarms may still be cleared while alarm cutoff is active).

OEM Sensors AXP Backplane ID (Emerson OEM)
Alarm cutoff is deactivated automatically after a timeout defined as a configuration parameter (see PPS user guide for the Shmm 500 for more details about TELCO Alarms configuration parameters).
This sensor reports the ID number of the IPMB backplane type. The 1406 and 1600 contain a readable value which reports a unique identifier of the backplane type. While the main purpose of this sensor is to report the unique ID of the backplane, it can also be used to determine if a SAM has connectivity problems to the backplane. This sensor is available on each physical ShMM controller.
z Sensor Reading - Unique identification number of the backplane
z Current State Mask - 0x00 = No failure reading ID 0x01 = ECC check failed on read value
z Events - No events are generated by this sensor.
This sensor reports the results of the U-Boot POST tests. This sensor is available on each physical ShMM controller. POST results are reported in an 8-bit bit-field. Any bit that is set (set to 1) indicates that the respective POST failure occurred.
z Sensor Reading - POST State in a 8-bit value according to the following mask definition:
Bit 7 - RTC Bit 6 - Watchdog Bit 5 - CRC Bit 4 - Ethernet Bit 3 - UART Bit 2 - I2C Bit 1 - Memory Bit 0 - IPMB
z Current State Mask - 0x01 = POST Passed 0x02 = POST Failed
z Events - Events are generated at shelf manager start up that will report failure events for each individual test that fails as follows:
Event Data Byte 1 = 0x61
Event Data Byte 2 = 0x3F
POST Sensor Reading = Bit 0 (IPMB)

Shelf FRU Info (Emerson OEM) OEM Sensors
This sensor reports the validity of the Shelf FRU Information. This sensor is available on each physical ShMM controller. The check it performs is basic checksum and length checks based on information of previous sections of the FRU area; and key bytes that are expected to have certain values.
z Sensor Reading - 0x00 (meaningless since discrete sensor reading)
z Current State Mask - 0x01 Shelf FRU Info not found (Disabled) 0x02 Shelf FRU Info found (Enabled)
z Events - Events are generated when the state of the FRU Info found state changes.
Event Data Byte 1 = 0x01 Shelf FRU Info not found (Disabled) 0x02 Shelf FRU Info found (Enabled)
Event Data Byte 2 = 0xFF (Unspecified)
Event Data Byte 3 = 0xFF (Unspecified)
This sensor reads the System Status Register of the respective Fan Tray and verifies if the bit for 48 V input power OK is set. The 48 V input power ok bit is set if all input fuses are intact.
z Sensor Reading - 0x00 (NULL Discrete sensor reading)
z Current State Mask - 0x01 (State Deasserted, all input fuses are intact) 0x02 (State Asserted, not all input fuses are intact)
z Events - No events are generated by this sensor.
Bit 5 (CRC) · Bit 6 (Watchdog) · Bit 7 (RTC)

OEM Sensors Shm Fault Event (Emerson OEM)
This sensor reports the status of Fault Classes on the Active shelf. When the value is read it indicates the presence or absence of each fault class. Currently defined fault classes relate to the health of the FTMs in the shelf.
z Sensor Reading - This is a 2-byte bit mask of active fault conditions detected by the sensor. A '1' in any bit indicates the specified fault is active. Refer to the following table for fault classes.
z Current State Mask - 0x1FE - mask of possible fault event bits
z Events - For FTM-related faults, an event is generated when any FTM transitions into or out of a fault condition. An event is flagged as an assertion event when at least one FTM exhibits the fault class. It is flagged as a deassertion event when no FTMs remain with the fault class.
Table 3-1 Shm Fault Classes
0 Not used.
1 One or more fan trays are missing.
2 One or more fan trays' speed sensors are below critical threshold.
By default, all of a FTM's speed sensors must be below critical speed in order to declare a fault at that FTM; however through a new configuration option in shelfman.conf, the administrator can change the behavior to declare a fault if any speed sensor is critical.
3 One or more fan trays' speed sensors do not show significant increase when the active shelf manager asserts FULL_SPEED signal as part of the Fan Tray Latent Fault Check algorithm. (Active FULL_SPEED test)
4 One or more fan trays' speed sensors do not return to a normal speed following the release of FULL_SPEED signal by the active shelf manager, as part of the Fan Tray Latent Fault Check algorithm. (Active FULL_SPEED test)
5 One or more fan trays' speed sensors do not show significant increase when the redundant shelf manager asserts FULL_SPEED signal as part of the Fan Tray Latent Fault Check algorithm. (Redundant FULL_SPEED test)
6 One or more fan trays' speed sensors do not return to a normal speed following the release of FULL_SPEED signal by the active shelf manager, as part of the Fan Tray Latent Fault Check algorithm. (Redundant FULL_SPEED test)
7 One or more fan trays' speed sensors do not show significant increase when the active shelf manager increases the speed level to its maximum value as part of the Fan Tray Latent Fault Check algorithm. (PSOC LFC test)
8 One or more fan trays' speed sensors do not return to a normal speed following the lowering of the speed level by the active shelf manager, as part of the Fan Tray Latent Fault Check algorithm. (PSOC test)
Fault Class Meaning

A
Sensor Events
A.1 Introduction
This chapter introduces important information for those who are developing their own applications code, based on how the Centellis 3406 and 3600 system behaves to different events.
The Shelf Manager operates in normal mode with respect to cooling if no temperature sensor in the shelf reports crossing of one of the upper thresholds (noncritical, critical or nonrecoverable). In that case, there is no need to accelerate the fan speed.
On the contrary, the Shelf Manager in normal mode periodically reduces the fan speed by FAN_LEVEL_STEP_DOWN* levels (once per COOLING_FAN_DECREASE_TIMEOUT* seconds) until the fan speed reaches the minimum fan level or the shelf goes to abnormal mode (with at least one of the temperature sensors reporting one of its upper thresholds crossed). The minimum fan level is initially specified as a configuration parameter, but its value is adjusted if the transition to the abnormal mode happens, in order to prevent subsequent recurrence of the thermal alert.
The Shelf Manager operates in abnormal mode with respect to cooling if at least one temperature sensor in the shelf reports crossing of one of the upper thresholds (noncritical, critical or nonrecoverable). In that case, the Shelf Manager takes over the control of all fan trays, including those that support local control mode, but excluding any fans for which the Get Fan Level command reports that the fan is in 'Emergency Shut Down' mode. The Shelf Manager raises the fan speed by FAN_LEVEL_STEP_UP* levels for every fan tray every COOLING_FAN_INCREASE_TIMEOUT* seconds until the temperature reported by all temperature sensors falls below the thresholds.
Additionally, when at least one critical temperature threshold has been exceeded, the Shelf Manager starts reducing the power level of FRUs one level each COOLING_POLL_TIMEOUT* seconds, if possible. FRUs are not powered down in that case, for example, SetPowerLevel(0) is not issued. In that state, the Shelf Manager also immediately raises the level of all fans to the maximum level and keeps it at maximum.

System Behavior in Response to Sensor Events Adaptive Adjustment of the Minimum Fan Level
When at least one nonrecoverable temperature threshold has been exceeded on a FRU, the Shelf Manager powers down the FRU (sending them the SetPowerLevel(0) command) and refuses to power the FRU back up for COOLING_POLL_TIMEOUT* seconds. In that state, the Shelf Manager also immediately raises the level of all fans to the maximum level and keeps it at maximum.
The Shelf Manager changes the minimum fan level over time to prevent oscillations of the shelf between normal and abnormal cooling mode. When the shelf transitions from normal to abnormal cooling mode, this means that the current fan level is insufficient for effective cooling of the shelf. In that case, the Shelf Manager dynamically changes the minimum fan level to the current level + 1, so that next time in normal mode the Shelf Manager will not try to decrease the fan level so low. (In the case of multiple fans and different fan levels, the Shelf Manager chooses the maximum current fan level.) This makes the algorithm to converge to a certain fan level after several oscillations; at that level, the shelf operates in normal cooling mode and this is the minimum possible fan level at which the shelf can operate in normal cooling mode.
To accommodate for possible changes in the thermal load in the shelf in a long run, an additional enhancement is implemented. After the shelf stays in normal cooling mode at a stable fan level for a substantial period of time (specified as a configuration parameter NORMAL_STABLE_TIME*, with a default of 1 hour), the minimum fan level is decreased by one and the current fan level is allowed to drop to the new minimum. If the thermal load in the shelf has decreased, the shelf will continue to operate at the reduced fan level. Otherwise, the shelf will transition to the abnormal cooling state and the fan level will converge to a new stable value after several oscillations.

Adaptive Adjustment of the Minimum Fan Level System Behavior in Response to Sensor Events
The following graph illustrates the behavior of the above cooling algorithm in finding a stable fan level in real shelf, in the presence of a substantial thermal load in the shelf. The configuration parameter NORMAL_STABLE_TIME* is set to 30 minutes. The graph presents the fan speed changes over a period of 70 minutes. The horizontal axis has time scaled from 0 to 70 minutes.
Figure A-1 Cooling Algorithm

The fan speed is initially lowered to 3. This causes a thermal alert and after a single increase in fan speed, during the subsequent fan speed reduction, the level stabilizes at 4. After the expiration of a period defined by the parameter NORMAL_STABLE_TIME* (which is equal to 30 minutes) the level is lowered to 3 which again causes a thermal alert, an increase in fan speed with subsequent reductions, and the fan level again stabilizes at 4.
* These are configurable options in /etc/shelfman.conf. If these values are not defined in shelfman.conf, default levels are used.

System Behavior in Response to Sensor Events FRU State Management
The following table provides the SAM action, FRU status, hot swap state for each FRU temperature sensor in the shelf.
Table A-1 FRU State Table for Nonrecoverable Threshold Events from Temperature Sensors
FRU Temperature Sensor SAM Action FRU Status
Hot Swap State H/S LED
Sensor # 6("MAX6656 INT @1A") Sensor # 7("MAX6656 EXT1 @1A") Sensor # 8("MAX6656 EXT2 @1A")
Set all FAN- module speed MAX
H/S LED ON. Still working as Active.
M6->M1 (Logical SAM (0x20) will show M4 state)
Sensor # 6("MAX6656 INT @1A") Sensor # 7("MAX6656 EXT1 @1A") Sensor # 8("MAX6656 EXT2 @1A")
Set all FAN- module speed MAX
H/S LED ON.
PEM Sensor # 12 ("DS75 Temp") Set all FAN- module speed MAX
Issue "deactivate" command to PEM
Still working. M6 > M1 Turn ON
Sensor # 8 ("Inlet Temp") Set all FAN- module speed MAX
Issue "deactivate" command to F101
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 9 ("Outlet Temp") Set all FAN- module speed MAX
Issue "deactivate" command to F101
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 10 ("PMC Temp") Set all FAN- module speed MAX
Issue "deactivate" command to F101
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 20 ("Artesyn Temp") Set all FAN- module speed MAX
Issue "deactivate" command to F101
Payload powered down by the SAM.
M6 > M1 Turn ON

FRU State Management System Behavior in Response to Sensor Events
Table A-1 FRU State Table for Nonrecoverable Threshold Events from Temperature Sensors (continued)
FRU Temperature Sensor SAM Action FRU Status
Hot Swap State H/S LED
ATCA- 7221 Sensor # 0 ("BrdTempNearPMC")
Set all FAN- module speed MAX
Issue "deactivate" command to 7221
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 1 ("Temp Near Mem ") Set all FAN- module speed MAX
Issue "deactivate" command to 7221
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 2 ("Temp CPU 0") Set all FAN- module speed MAX
Issue "deactivate" command to 7221
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 3 ("Temp CPU 1") Set all FAN- module speed MAX
Issue "deactivate" command to 7221
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 6 ("Die Temp CPU 0") Set all FAN- module speed MAX
Issue "deactivate" command to 7221
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 7 ("Die Temp CPU 1") Set all FAN- module speed MAX
Issu e "deactivate" command to 7221
Payload powered down by the SAM.
M6 > M1 Turn ON
Sensor # 10 ("12V DCDC Temp.")
Set all FAN- module speed MAX
Issue "deactivate" command to 7221
Payload powered down by the SAM.
M6 > M1 Turn ON
Step-1 Step-2 Operation

System Behavior in Response to Sensor Events FRU State Management

B
B.1 Emerson Network Power - Embedded Computing Documents
The Emerson Network Power - Embedded Computing publications listed below are referenced in this manual. You can obtain electronic copies of Emerson Network Power - Embedded Computing publications by contacting your local Emerson sales office. For documentation of final released (GA) products, you can also visit the following website: http://www.emersonnetworkpowerembeddedcomputing.com > Solution Services> Technical Documentation Search. This site provides the most up-to-date copies of Emerson Network Power - Embedded Computing product documentation.
Table B-1 Emerson Newtork Power - Embedded Computing Documents
Document Title Publication Number
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference 6806800B66
Centellis R2 (AXP1405) to R3 (AXP1406/AXP1600) Porting Reference 6806800C31
ATCA-F101-5E System Controller and Switching Blade Installation and Use
ATCA-7221 Reference Guide 6806800A50
ATCA-7107 Reference Guide 6806800A48
ATCA-S100 Reference Guide 6806800A36
ATCA-F101 Basic Blade Service Software Release 3 6806800C12
ATCA-7221 Basic Blade Service Software Release 3 6806800C14
ATCA-F101 Basic Blade Service Software Release 3 6806800C13
Centellis 3406/3600 Release 3.0 Document Collection 6806800C29
Pigeon Point Shelf Manager External Interface Reference, Release 2.1.1 DOCSHMEXTINT
Pigeon Point IPM Sentry Shelf Manager User Guide, 2.1.1 DOCSHMUG

Related Documentation Manufacturers’ Documents
For additional information, refer to the following table for manufacturers’ data sheets or user’s manuals. As an additional help, a source for the listed document is provided. Please note that, while these sources have been verified, the information is subject to change without notice.
Table B-2 Manufacturers Documents
Document Title Web Site Source
IPM Sentry Shelf Manager User Guide http://www.emersonnetworkpowerembeddedcompu ting.com
IPM Sentry Shelf - External Interface Reference, Release
http://www.emersonnetworkpowerembeddedcompu ting.com
For additional information, refer to the following table for related specifications. As an additional help, a source for the listed document is provided. Please note that, while these sources have been verified, the information is subject to change without notice.
Table B-3 Related Specifications
IPMI Specifications, http://www.intel.com/design/servers/ipmi
IPMI Spec v1.5, Document Revision 1.1, February 20, 2002 Intel Corporation, Hewlett- Packard, DEC, NEC
IPMI v1.5 Addenda, Errata, and Clarifications, Addendum Document Revision 5, January 29, 2004
Intel Corporation, Hewlett- Packard, DEC, NEC
Intelligent Platform Management Interface Specification v1.0, Document Revision 1.1, November 15 1999
Intel Corporation, Hewlett- Packard, NEC, Dell
IPMI Implementer's Guide, Draft Version 0.7, September 16, 1998 Intel Corporation
IPMI Platform Management FRU Information Storage Definition V1.0, September 27, 1999
PCI Industrial Manufacturers Group (PICMG) http://www.picmg.com/
AdvancedTCA Base 3.0 Specification, Revision 2.0 PICMG 3.0 R 2.0,Dated 03/18/05