Installation and Use
July 2009

2009 Emerson All rights reserved.
Trademarks Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2009 Emerson Electric Co. All other product or service names are the property of their respective owners. Intel® is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. Java™ and all other Java-based marks are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other Countries. Microsoft®, Windows® and Windows Me® are registered trademarks of Microsoft Corporation; and Windows XP™ is a trademark of Microsoft Corporation. PICMG®, CompactPCI®, AdvancedTCA™ and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI Industrial Computer Manufacturers Group. UNIX® is a registered trademark of The Open Group in the United States and other countries.
Notice While reasonable efforts have been made to assure the accuracy of this document, Emerson assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes. Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to a Emerson website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise altered without the permission of Emerson, It is possible that this publication may contain reference to or information about Emerson products (machines and programs), programming, or services that are not available in your country. Such references or information must not be construed to mean that Emerson intends to announce such Emerson products, programming, or services in your country.
Limited and Restricted Rights Legend If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply unless otherwise agreed to in writing by Emerson. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and Documentation clause at DFARS 252.227-7014 (Jun. 1995).
2900 South Diablo Way, Suite 190 Tempe, AZ 85282


3 NEW SYSTEM CONFIGURATION .................................................................................................20
3.1 RS232 CONSOLE PORT 21 3.1.1 System boot overview 21 3.1.2 Flash boot device contents 22 3.1.3 Linux serial console shell window 23 3.2 DEFAULT BLADE LOGIN ACCOUNTS AND PASSWORDS 23 3.2.1 Password change procedure 23 3.2.2 Password recovery procedure 23 3.3 FACTORY RESET 24 3.4 CONFIGURING A NEW ATCA-S201 BLADE 24 3.4.1 Serial ports 24 3.4.2 Ethernet ports 24 3.4.3 Management Configuration via HTML browser 25 3.4.4 Management configuration via secure shell (SSH) 25 3.4.5 Management configuration via serial console shell 25 3.5 COMMAND LINE CONFIGURATION TOOL 26 3.5.1 Change IP address of any Ethernet resource 26 3.5.2 Shell, configuration scripting options 28 3.6 NEW SYSTEM CONFIGURATION, NO DHCP SERVER 29 3.6.1 U-boot console tool 30 3.6.2 Essential U-boot user commands 30 3.6.3 U-boot environment variables 31 3.6.4 Manually assign management IP addresses 32 3.7 NETWORK BOOT PROCEDURE 33
4.1 ENABLE HTML BROWSER ACCESS 35 4.2 HTML SECURITY CERTIFICATES (HTTPS:// ) 35 4.3 HTML LOGIN SCREEN 35 4.3.1 Auto logout inactivity period 36 4.3.2 Single session management override 36 4.4 HTML HOME PAGE 36 4.5 ESSENTIAL SYSTEM CONFIGURATION STEPS 37 4.6 SYSTEM IDENTIFICATION AND TIME ZONE ATTRIBUTES 38 4.6.1 Hostname 39 4.6.2 Domain Name 39 4.6.3 Date 39 4.6.4 Time 40 4.6.5 Time Zone 40 4.6.6 Name Server list 41 4.6.7 NTP Server list 41 4.6.8 Network time protocol - NTP (On/Off) 42 4.6.9 Ethernet network port identification 42 4.6.10 Enable (online/offline) 43 4.6.11 DHCP 43 4.6.12 IP address 43
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide ii

4.6.13 Network (Subnet) mask 43 4.6.14 Broadcast 44 4.6.15 Gateway 44 4.6.16 MTU size 44 4.6.17 MAC address 44 4.7 VLAN VIRTUAL LOCAL AREA NETWORK SUPPORT 45 4.7.1 Viewing active VLAN 46 4.8 LINK AGGREGATION AND BONDING 47 4.8.1 Bonding, CLI command syntax 48 4.9 SHELF COMMUNICATIONS 49 4.10 I/O STATUS ATTRIBUTES 50 4.11 BLADE MAINTENANCE, MISCELLANEOUS OPERATIONS 51 4.11.1 Rescan SAS Topology, disk refresh 52 4.11.2 Software Reset SAS Controller 52 4.11.3 Reset I/O Status counters 52 4.12 CPU STATUS ATTRIBUTES 53 4.13 ATCA STATUS ATTRIBUTES 54
5.1 HARDWARE RAID CONFIGURATION 57 5.1.1 JBOD mode 58 5.2 HARDWARE RAID CONFIGURATION MENU USAGE 58 5.2.1 Hardware RAID levels and capabilities 60 5.2.2 How new RAID definitions alter device menu display 60 5.2.3 Modify existing RAID configurations 61 5.3 SOFTWARE RAID CONFIGURATION 63 5.3.1 Software RAID web-configuration menu usage 63 5.3.2 Software RAID, CLI command syntax 64 5.3.3 Software RAID levels and capabilities 66
6.1 BENEFITS OF A LOGICAL VOLUME GROUP (/DEV/VGA) 67 6.1.1 Benefits of a Logical device/disk (/dev/vga/lva0) 67 6.2 VIEWING PHYSICAL DISKS 68 6.2.1 Interpreting physical disk status 68 6.2.2 View physical disk properties 69 6.3 CREATE A LOGICAL VOLUME GROUP (/DEV/VGA) 70 6.4 CREATING A LOGICAL DEVICE (/DEV/VGA/LVA0) 73 6.4.1 Extend/Expand a Logical Device (/dev/vga/lva0) 73 6.4.2 Delete a Logical device (/dev/vga/lva0) 74 6.5 MANAGE SHARES (PREPARE LOGICAL DEVICE FOR SERVICE) 75 6.5.1 Commit a logical drive for iSCSI service 75 6.5.2 Commit a logical drive for NAS service 76 6.5.3 Un-commit an iSCSI share 77 6.5.4 Un-commit an NFS/SMB share 78 6.6 RE-NAME ISCSI SHARES, MAKE MORE ‘HUMAN-FRIENDLY’ 79
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide iii






Safety Summary
The following general safety precautions must be observed during all phases of operation, service, and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual could result in personal injury or damage to the equipment.
The safety precautions listed below represent warnings of certain dangers of which Emerson is aware. You, as the user of the product, should follow these warnings and all other safety precautions necessary for the safe operation of the equipment in your operating environment.
GROUND THE INSTRUMENT. To minimize shock hazard, the equipment chassis and enclosure must be connected to an electrical ground. If the equipment is supplied with a three-conductor AC power cable, the power cable must be plugged into an approved three-contact electrical outlet, with the grounding wire (green/yellow) reliably connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable meet International Electrotechnical Commission (IEC) safety standards and local electrical regulatory codes.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. Do not operate the equipment in any explosive atmosphere such as in the presence of flammable gases or fumes. Operation of any electrical equipment in such an environment could result in an explosion and cause injury or damage.
KEEP AWAY FROM LIVE CIRCUITS INSIDE THE EQUIPMENT. Operating personnel must not remove equipment covers. Only Factory Authorized Service Personnel or other qualified service personnel may remove equipment covers for internal subassembly or component replacement or any internal adjustment. Service personnel should not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable removed. To avoid injuries, such personnel should always disconnect power and discharge circuits before touching components.
USE CAUTION WHEN EXPOSING OR HANDLING A CRT. Breakage of a Cathode-Ray Tube (CRT) causes a high-velocity scattering of glass fragments (implosion). To prevent CRT implosion, do not handle the CRT, and avoid rough handling or jarring of the equipment. Handling of a CRT should be done only by qualified service personnel using approved safety mask and gloves.
DO NOT SUBSTITUTE PARTS OR MODIFY EQUIPMENT. Do not install substitute parts or perform any unauthorized modification of the equipment. Contact your local Emerson representative for service and repair to ensure that all safety features are maintained.
OBSERVE WARNINGS IN MANUAL. Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. You should also employ all other safety precautions which you deem necessary for the operation of the equipment in your operating environment.
To prevent serious injury or death from dangerous voltages, use extreme caution when handling, testing, and adjusting this equipment and its components. Warning
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide i

All Emerson PWBs (printed wiring boards) are manufactured with a flammability rating of 94V-0 by UL-recognized manufacturers.
This equipment generates, uses, and can radiate electromagnetic energy. It may cause or be susceptible to electromagnetic interference (EMI) if not installed and used with adequate EMI protection.
The ATCA-S201 is designed to comply with EN60950-1, and is intended to be used with similarly tested ATCA and AMC products that have a user’s guide detailing user installation of AMC module accessories.
Emerson Networks products with the CE marking comply with the EMC Directive (89/336/EEC). Compliance with this directive implies conformity to the following European Norms:
EN55022 “Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment”; this product tested to Equipment Class A EN50082-1:1997 “Electromagnetic Compatibility–Generic Immunity Standard, Part 1. Residential, Commercial and Light Industry”
System products also fulfill EN60950 (product safety), which is essentially the requirement for the Low Voltage Directive (73/23/EEC).
Board products are tested in a representative system to show compliance with the above mentioned requirements. A proper installation in a CE-marked system will maintain the required EMC/safety performance.
In accordance with European Community directives, a “Declaration of Conformity” has been made and is on file within the European Union. The “Declaration of Conformity” is available on request. Please contact your sales representative.
While reasonable efforts have been made to assure the accuracy of this document, Emerson Networks, Inc. assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.
Electronic versions of this material may be read online, downloaded for personal use. The text itself may not be published commercially in print or electronic form,
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide ii
Preface

edited, translated, or otherwise altered without the permission of Emerson Networks, Inc.
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide iii
Preface

This manual supports the following configurations and model numbers.
ATCA-S201 10GbE RAID Storage-IP Carrier blade
This manual is divided into the following chapters and appendices:
Chapter 1 provides a 6ATCA-S201 Overview
Chapter 2 provides instructions for Installation
Chapter 3 provides the procedures for a 6New System configuration
Chapter 4 Provides details regarding Network configuration
Chapter 5 provides details for RAID Volume Configuration
Chapter 6 provides instructions for sharing devices as NAS or iSCSI
Chapter 7 provides information for iSCSI LUN configurations
Chapter 8 provides information for NFS and SMB file sharing configurations
Chapter 9 provides 6Blade Maintenance and Firmware upgrades
Chapter 10 provides 6ATCA-S201 Mechanical and Connector Information
Chapter 11 provides overview on RTM-ATCA-SXXX
Chapter 12 provides instructions for installing the RTM-ATCA-SXXX
Chapter 13 provides RTM-ATCA-SXXX connector information
Chapter 14 provides 6IPMI Functions List
Chapter 15 provides 6IPMC Firmware Upgrade Procedure
The following typographical conventions are used in this document:
Table 1 Conventions used in this manual
Convention Is used for
bold User input that you type just as it appears; it is also used for commands, options and arguments to commands, and names of programs, directories and files.
italic Names of variables to which you assign values, for function parameters, and for structure names and fields. Italic is also used for comments in screen displays and examples, and to introduce new terms.
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide iv
Part Number Description

courier System output (for example, screen displays and reports), examples, and system prompts.
ENTER The carriage return or Enter key.
CTRL The Control key. Execute control characters by pressing the CTRL key and the letter simultaneously, for example, Ctrl+D.
6806800H62B ATCA‐S201 Installation and Use Guide v

Unpacking Instructions
If the shipping carton is damaged upon receipt, request that the carrier’s agent be present during the unpacking and inspection of the equipment.
Unpack the equipment from the shipping carton. Refer to the packing list and verify that all items are present. Save the packing material for storing and reshipping of equipment.
Avoid touching areas of integrated circuitry. Static discharge can damage circuits.
After removing the product from the packaging:
Check for obvious physical damage. Make sure that you disconnect the chassis from the main power supply before you continue.
Emerson strongly recommends that you use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to electrostatic discharge (ESD). After removing the component from its protective wrapper or from the system, place the component flat on a grounded, static-free surface (and, in the case of a board, component side up). Do not slide the component over any surface.
If an ESD station is not available, you can avoid damage resulting from ESD by wearing an antistatic wrist strap (available at electronics stores) that is attached to an active electrical ground. Note that a system chassis may not be grounded if it is unplugged.
Avoid touching areas of integrated circuitry. Static discharge can damage these circuits.
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide vi

The Emerson ATCA-S201 is an ATCA carrier blade that supplies multi-protocol IP storage services to the chassis Zone-2 backplane using Ethernet connections. The ATCA-S201 virtualizes capacity of AMC SAS/SATA disks and creates multiple logical volumes which are mapped as iSCSI, NFS or SMB targets. Using access control lists, ATCA server blades are given authorization to connect with virtualized volumes via 10 GbE fabric or 1GbE base connections.
The ATCA-S201 carrier can accommodate up to four AMC disk modules. Additional disks may be added using an Advanced ARTM which adheres to the Advanced RTM zone-3 connector pin out.
Users may also deploy the ATCA-S201 to realize gateway functions with external equipment including SAS and/or Fiber channel (FC) storage area networks (SANs). For example, populate with an AMC 4 Gb FC controller modules, and establish gateway services between LUN volumes in the FC data center and the ATCA GbE network.
The ATCA-S201 is single slot carrier board for ATCA shelves. Measuring 8U (280mm) x 325 mm, the carrier includes four advanced mezzanine card (AMC) slots for storage disks or SAN connections. Several on board Ethernet controllers provide connections to the base and fabric interfaces.
The prominent digital components include:
Freescale® 1.3Ghz, super scalar PowerPC processor Intel® dual port 10 GbE Ethernet controller LSI® 8 port SAS controller, with RAID PLX® 48 Lane PCI Express Switch 1GB SODIMM, 533MHz DDR2, with ECC (72b) Carrier IPMC, with hot swap and LED control FRUID serial EERPORM (note: The FRU ID is not a separate part but rather embedded in the MMC controller.) Temperature sensors Voltage sensors SPI flash memory
The ATCA-S201 is loaded with software which enables it to terminate several IP protocols, and efficiently map these protocols to block I/O storage using SAS/SATA disks, and optional RAID protection. This product can also map IP protocols to Fibre Channel SAN resources, if populated with a 4Gb Fibre channel AMC module. Key software services include:
iSCSI service (IETF RFC-3720) NFS service version 3 (network file share) SMB service (Server Message Block file system) Integrated RAID0, RAID1 and RAID1E service SNMP HTML web configuration client
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 7
ATCA-S201 Overview

The ATCA-S201 10Gb RAID Storage-IP Carrier ATCA is fully compliant with the following PCI Industrial Computer Manufacturers Group (PICMG) specifications:
PICMG 3.0 Advanced Telecommunications Computing Architecture (ATCA) PICMG 3.1 Ethernet for ATCA Systems AMC.0 Advance Mezzanine Card Base Specification AMC.1 PCI Express and Advanced Switching AMC.3 AMC Storage IPMI v1.5 Intelligent Platform Management Interface Specification PCI Express 1.0a
The ATCA-S201 provides several sockets and slots to facilitate operation in an ATCA chassis. In addition to 4 AMC modules, the module includes chassis backplane connections including ATCA zone-1 (power), zone-2 (fabric) and zone-3 (Advanced rear transition module).
Zone 3 to RTM
4 SATA/SAS x1 SAS
1 Gb 1 Gb
DDR2, FLASH 8 PCI-E
ATCA
10 Gb 10 Gb
8 PCI-E
X1 SAS
8 SAS
LSI 1068E SAS/RAID 8 PCIE
24 PCI-E
24 PCI-E
X1 SAS
IPMI (PPS)
X1 SAS

Figure 1, ATCA-S201 functional block diagram
The four AMC slots have identical features, and each accommodates a half width, mid height module. The ATCA-S201 accepts AMC cards conforming to either PCI express signaling (AMC.1) or Storage signaling options (AMC.3). AMC feature support details:
PCI-Express x4 on AMC ports 4-7 PCI reference clock on FCLKA 3Gb SAS/SATA on AMC port2 3Gb SAS/SATA on AMC port3 SAS hot swap support Face plate height x width, 18.96 x 73.8mm IPMB-L 72W max each slot (120W shared with all AMC slots)
A 72 bit SODIMM socket is populated with a DDR2 memory module, and operated at 533MHz. The ATCA applies ECC (error correction code) algorithms to this memory to ensure data integrity of both the storage and program code stored in it. Single bit errors are automatically detected and corrected by these ECC algorithms.
The Zone-1 connector brings 48V DC power into the ATCA main board. This power is regulated and split into several lower voltages by discrete components and a pair of power modules that are affixed to the ATCA carrier. Together, these devices convert 48V source and distributes power amongst the ATCA local onboard needs, AMC slots and advanced rear transition module (RTM).
This connector carries the Ethernet links to the chassis backplane. All Ethernet ports on this connector are full duplex and all ports support access to advertised storage resources. This connector includes the following Gigabit Ethernet ports:
2 Fabric channels, redundant 10GbE XAUI connections 2 Base channels, redundant 1GbE base connections
This connector conforms to the advanced rear transition module (RTM) 3-row connector standard. The following functions are routed to this connector:
8x PCI-express 4x SAS/SATA target connections 4x SAS/SATA initiator connections I2C support
ATCA‐S201 Overview

12V and 3.3V supply voltage 1GbE management RS232 management
An Ethernet management port is routed to the Zone 3 connector. An advanced RTM with an RJ-45 connector is needed to access this port. The port auto negotiates to either 10/100/1000BASE-T.
An RS232 serial management port is routed to the Zone 3 connector. An advanced RTM with an RJ-45 connector is needed to access this port.
ATCA‐S201 Overview

Several LEDs are located on the panel of the ATCA-S201 Advanced TCA Carrier.
Out of Service (OOS)
Figure 2 Front view- fully populated ATCA-S201 showing panel LEDs
ATCA‐S201 Overview · Boot Status · Hot Swap

Table 2 LED functional description LED Description
Off: Normal, default state Blue-Blinking: Preparing for hot swap Blue-ON: ready for hot-swap removal ATCA Blade OK LED Green-ON: Blade Optimal
ATCA Hot Swap LED
ATCA Out of service (OOS)
The ATCA-S201 provides several IP storage services over the 10GbE fabric and 1 GbE base connections. Major services include iSCSI, NFS, and SMB. ATCA node boards with standard OS installations, require no special drives from Emerson. This product is compatible with the following operating systems and services:
Solaris 10 (SPARC) Operating System, NFS Solaris 10 (SPARC) Operating System, iSCSI initiator Solaris 10 (x86) Operating system, NFS Solaris 10 (x86) Operating system, iSCSI initiator SuSE Linux Enterprise Server 10, NFS SuSE Linux Enterprise Server 10, iSCSI initiator RedHat Enterprise Linux 5.0_u4, NFS RedHat Enterprise Linux 5.0_u4, iSCSI initiator Windows Server 2003 CIFS (a dialect of SMB) Windows Server 2003, iSCSI initiator
At manufacturing time, several labels are affixed to the ATCA-S201 as shown below. For proper identification of the AMC module, use these barcode labels to determine the module identity. The barcode labels provide the following information:
Table 3 ATCA-S201 Identification Labels
AAA = Assembly Number (100)
L =Location of manufacturer (S)
Y = Calendar year of manufacturer (2008 = 8)
MM = Calendar month of manufacturer (March = 03)
SSSS = Sequence number (reset each month) (1234)
ATCA‐S201 Overview · Label Description

This label contains 2 numbers:
(example:
Top = Internal Part Number
Bottom = Orderable Part Number

Figure 3 ATCA-S201 Diagram Showing Identification Label Location
ATCA‐S201 Overview

This chapter contains the procedures for installing and removing the ATCA-S201 10GbE RAID storage services blade.
The ATCA-S201 10GbE RAID storage services blade can be installed into an ATCA shelf (chassis) with a midplane made for front and rear board installations.
The Chassis backplane often designates certain slots as hub slots and the others as general purpose node slots. Be certain to select a general purpose node slot for installation. If this installation includes a companion advanced rear transition module (ARTM), install the ARTM first. These back-to-back slots have cut-outs that permit the front carrier board to pass signals to the ARTM via the Zone-3 connector complex.
Before installing the blade module, verify the module’s part number to ensure that the correct module is being installed into the system. For information on identifying the blade module, see Section 1.6 Part Number, Serial Number, and Address Labels.
The ATCA-S201 is designed to comply with UL60950-1, and is intended to be used with similarly tested ATCA and AMC products that have a user’s guide detailing user installation.
Be sure to validate the host chassis, and the host chassis meets the maximum current requirements. The ATCA-S201 includes a stacked power supply module with maximum rated output of 210W of power. This represents a surplus of power vs. the expected power consumption.
Table 4 Max ATCA-S201 module Current requirements
Max ATCA blade Current Draw (unpopulated) 1.04 @ 48V (50 watts) Max current draw (each AMC slot) 72 watts (max each) Max current draw (ARTM slot) 25 watts (max)
2.08 @ 48V (100 watts) total shared power pool 3.12 Total Maximum
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 14
Module ATCA-S201

Boards may be damaged if improperly installed or handled. Please read and follow the guidelines in this section to protect your equipment.
Emerson strongly recommends that you use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to electrostatic discharge (ESD). After removing the component from its protective wrapper or from the system, place the component flat on a grounded, static-free surface (and, in the case of a board, component side up). Do not slide the component over any surface.
If an ESD station is not available, you can avoid damage resulting from ESD by wearing an antistatic wrist strap (available at electronics stores) that is attached to an active electrical ground. Note that a system chassis may not be grounded if it is unplugged.
Bent pins or loose components can cause damage to the board, the backplane, or other system components. Carefully inspect your board and the backplane for both pin and component integrity before installation. Our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving our factory. Bent pins caused by improper installation or by boards with damaged connectors could void the warranty for the backplane or boards.
If a system contains one or more crushed pins, power off the system and contact your local sales representative to schedule delivery of a replacement chassis assembly.
When installing boards in an empty chassis, we recommend that you start at the left of the card cage and work to the right. This helps to avoid mistakes in matching slots with the intended carrier boards. When inserting or removing a board in a slot adjacent to other boards, use extra caution to avoid damage to the pins and components located on the primary or secondary sides of the boards.
To preserve compliance with applicable standards and regulations for electromagnetic interference (EMI), during operation all front and rear openings on
ATCA‐S201 Installation

the chassis or board faceplates must be filled with an appropriate card or covered with a filler panel. If the EMI barrier is open, devices may cause or be susceptible to excessive interference.
The ATCA module is electrically designed for hot swap within a fully powered chassis. To facilitate hot swap, there is a blue LED on the front faceplate. This LED is under software control of the IPMC managers.
The manager will illuminate the blue hot swap LED on the front faceplate when software has stopped and it is safe to remove the advanced rear transition module. If the blue-LED is not illuminated or blinking, it is not ready for removal. Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.
The ATCA supports mechanical connector keying to help prevent installation with incompatible components and RTM. The ATCA carrier board utilizes an A1/K1 key that is set at for universal)
Prevent possible damage to module components by verifying the proper slot usage for your configuration.
In most cases, electronic keying (E-keying) will prevent power on of a board into an incompatible slot. However, as an extra precaution, you should be familiar with the slot purpose.
This section describes a recommended procedure for installing the ATCA carrier module in a chassis.
Before you install your module, please read all cautions, warnings, and instructions presented in this section.
Handling modules and peripherals can result in static damage. Use a grounded wrist strap, static-dissipating work surface, and antistatic containers when handling and storing components.
Insert the board by holding the Module Handles–do not exert unnecessary pressure on the faceplate.
Hot swap compliant modules may be installed while the system is powered on. If a module is not hot swap compliant, you should remove power to the slot or system before installing the module.
ATCA‐S201 Installation


Figure 4 Injector / Ejector latch and locking screw
ATCA‐S201 Installation

The ATCA-S201 ATCA carrier blade is hot-swappable and can be removed from a powered chassis. This section describes a recommended procedure for removing a board module from a chassis.
Before you remove your module, please read all cautions, warnings, and instructions presented in this section. Hot swap compliant modules may be removed while the system is powered on. When the lower ejector handle is partially disengaged, a mechanical switch will assert a signal to notify the IPMC to begin removal preparations. The IPMC will blink the blue hot-swap LED as it transitions the module to the appropriate power-down state. Upon completion and with permission from the ShMC, The blue LED will illuminate steady ON. This is the only indication that safe removal may commence. If the Blue LED is blinking or off, it is not ready for hot plug.
To remove the ATCA module, follow these steps:
This section provides information to verify the installation of the ATCA-S201 10 GbE RAID storage services module.
ATCA‐S201 Installation

If DHCP is running on the network, it is possible to immediately ping the Ethernet ports on the ATCA module. Open a command line window on any node, and attempt to ping the ATCA blade. ok ping 192.168.1.xxx
ATCA‐S201 Installation · MAC address OUI · 00-11-0D-xx-xx-xx (hex)

Ethernet Comm. Setup
NFS / SMB Share Setup
This chapter describes how to establish management communications with the ATCA-S201 for purposes including initial configuration, administration and monitoring the storage services. A typical ATCA deployment will consist of an ATCA chassis, ATCA carrier blades, Advanced RTM and shelf management controllers (ShMC). Administrators may choose from the following physical access ports to conduct management communications:
Full configuration capabilities:
- RS232 on Advanced Rear transition module (ARTM) - Ethernet on Advanced Rear transition module (1 GbE on ARTM) - Any zone 2 Ethernet connection (base or fabric)
In addition to DHCP, the ARTM Ethernet port offers special protocol services such as TFTP to recover corrupted flash or accidental erasure. All available management communications methods are outlined in this chapter.


Figure 5 Management communications port location diagram (Typical)
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 20

This port is implemented on an RJ45 connector located on the ARTM that supplies RS232 console port access. As the ATCA-S201 boots, its progress can be monitored on the console.
By default, this port is set for VT100 terminal emulation as listed in the table below.
Table 5 Console port, default terminal settings Baud rate (bits per second) 115200 Data bits 8 Parity None Stop bits 1 Flow control Off
A serial interface can be established using a null modem cable and virtually any terminal communications tool. If using a PC running Microsoft® Windows®, the user may use HyperTerminal. On Linux-based systems, Minicom can be used.
The ATCA-S201 is designed to boot and become ready for management logins without any user intervention. This is possible only if the supporting network offers DHCP. The ATCA-S201 requires no disk drives for initialization. At manufacturing time, two duplicate copies of firmware code are pre-loaded on non-volatile flash components embedded on the carrier board. These firmware images include U- boot, a Linux kernel, and the root file system (rfs) which contains the storage application services. On power-up or reset, the blade inspects jumper positions to decide whether firmware is fetched from the customer flash or a read-only factory flash. This feature allows blade recovery in situations where the customer flash has been accidently erased or corrupted. The blade boot sequence continues as the onboard CPU loads firmware and executes the code contents. If no attempts are made to halt or suspend the boot process, approximately 45 seconds later, the module is able to accept management communication logins and commands. Once booted, the blade runs entirely out of DDR2 SRAM embedded on the blade. All Ethernet ports are configured for DHCP. If DHCP is not used on your network, the ATCA-S201 Ethernet ports must be initialized manually as described in section 3.6 of this manual.


Figure 6 ATCA Blade boot sequence diagram
As mentioned in the previous section, the ATCA-S201 contains two flash images, which are preloaded with code at manufacturing. Each code image is divided into four major functional sections. Overtime, the customer may periodically updated individual sections with new code revisions, as outlined below:
U-boot.bin uImage Rootfs.ext.gz.uboot
Linux kernel code
File system code
User configuration settings
Figure 7 Boot-Flash device contents

If the boot is not interrupted and has completed, the RS232 port accepts administrator login for Linux shell access, and access to command line configuration tools.
After successful login, the user may run any of the command line configuration tools presented in section 3.4.5.
The ATCA-S201 includes two built-in user accounts for maintenance and management activities. Emerson recommends that administrators change the default passwords listed below for security purposes.
Table 6 Built-in user accounts included on a new ATCA-S201
User account Default password
admin admin The admin account was created for blade management activities. This account should be used for all management and configuration activities. Management logins may be performed via (1) Serial console RS232, (2) ssh or (3) secure html on any Ethernet port. root root The root account has master privileges with absolute power to modify the blades Linux OS in any way desired. It is unadvisable to use root as the normal user account because simple typographical errors, accidental file deletions, or generating unintentionally restrictive file permissions could render the blade in-operable, requiring the factory reset procedure. For normal activities, Emerson encourages using the admin user account and judicious use of the su command only when root privileges are really needed.
The login password may be changed using the linux passwd command. For example, if logged in as root, the password change procedure is shown: #passwd Changing password for root Enter the new password (minimum of 5, maximum of 8 characters) Please use a combination of upper and lower case letters and numbers. Enter new password: xxxxxxx Re-enter new password: xxxxxxx Password changed. #
In the event that the administrator login “root” is lost or forgotten, it is possible to clear it using jumpers provided on the ATCA-S201. The jumper location along with
Description

the clear password procedure is explained in section 9.4.3 of this manual. When invoked, the user is prompted to set a new one at first login.
Users can reset the blade to restore factory default settings. This procedure will erase all existing blade configurations (network settings, volumes, shares etc). The procedure is sometimes recommended following a major firmware upgrade.
i. Login into shell window as root
Initial configuration and setup of your blade may be conducted over Ethernet or serial (RS232) connections. Select the connection type that supports your preferred management style, either CLI (command line tool) or HTML as outlined below:
Connection type Command line tool Secure html tool
Serial/RS232 port on RTM Yes Ethernet port on RTM Yes Yes
Base or fabric ports on ATCA Zone-2 connector
An RJ45 serial port can be found on RTM panel. The default baud rate and communication settings are listed in Table 5 Console port, default terminal settings in section 3.1.2. The serial port attributes such as baud rate may be changed in the U-boot environment using the bootargs variable (see section 3.6.3 titled U-boot environment variables).
An RJ45 Ethernet port can be found on RTM panel. It auto negotiates Ethernet link speed s up to 1Gbps. Additional Ethernet ports (base and fabric) are provided on the ATCA zone-2 connector. By default, all Ethernet ports will attempt to obtain an IP address assignment form the DHCP (Dynamic Host Configuration Protocol) server on the network. Administrators must log into your DHCP server to determine the IP assignment. With the IP address, an administrator may connect to the ATCA-S201 using a secure shell (SSH) or an HTML browser which supports secure http connections. The Ethernet equipment can be identified by finding the IP address(es) corresponding to the following MAC address assignments:
Yes Yes · MAC address OUI · 00-11-0D-xx-xx-xx (hex)

Once the IP address of the Ethernet port is known, an administrator may use a web browser to connect to the ATCA-S201 to perform and monitoring or configuration tasks. For security, the browser must support secure https connections on TCP port 443.
Refer to chapter 4 , which begins the explanation and use of the html configuration tool.
Once the IP address of the Ethernet port is known, an administrator may use a SSH service to connect to the ATCA-S201 and to facilitate command line management.
If the boot is not interrupted and has completed, the RS232 port accepts administrator login for Linux shell access, and access to command line configuration tools.
******************************************************* Welcome to the Emerson ATCA-S201 Storage Blade * Type atca_blade to manage this blade, or use the * * Web Based Management tool by browsing to: * * https://ipaddr where ipaddr is the network address * * of the blade. ******************************************************* WebHost.WebDomain login: admin Password:admin
After successful login, the user may run any the shell configuration tools presented in section 3.4.5.

This tool is available from either the RS232 console or a linux secure shell connection. After successful login, the user may run an executable file “atca_blade” located in the /web/cgi-bin directory. The tool provides the user with a simple menu interface, to perform interactive parameter modifications. A sample session is shown below. #ssh 192.168.1.xxx -l root [email protected]'s password: root Last login: Tue Nov 20 17:34:30 2007 from 192.168.1.xxx # cd /web/cgi-bin /web/cgi-bin # atca_blade
The ATCA-S201 provides multiple Ethernet interfaces that host blades may use for initial setup and configuration. These ports are identified with the Linux resource labels shown in the table below
Table 7 Ethernet ports for chassis communications (base/fabric) Linux interface identifier description /dev/eth0 Chassis Base port 0, 1Gb link /dev/eth1 Chassis Base port 1, 1Gb link /dev/eth2 RTM, Rear I/O management port. /dev/eth3 Chassis fabric port 0, 10Gb XAUI link /dev/eth4 Chassis fabric port 1, 10Gb XAUI link
Perform manual Interactive changes
After invoking the command line tool (atca_blade), the user can modify any of the parameters within the functional groupings listed above. For example, select the “2. Network Settings” group. The configuration tool will display the entire list parameters in the group, along with their present values. Main Page for CLI Interface 1. IPMI Settings (get_status) 2. Network Settings (set_network) 3. Hardware Raid Configuration (set_raid) 4. Logical Volume Mangager LVM2 Configuration (set_lvm2) 5. Manage Shares (set_shares) 6. smb Configuration (set_smb) 7. nfs Configuration (set_nfs) 8. iSCSI Configuration (set_iscsi) 9. Web gui enable (set_gui) 10. Allow Web and CLI at the same time (set_useroverride) 0. Exit Enter choice [1-10], 0 to exit: [0]: 2
System Identification and TimeZone Active Settings Hostname=[BladeHost]: DomainName=[Emerson.com]

Date=[12/19/2007]: Time=[17:25:07]: TimeZone=[US/Eastern]: NTPServer[0]=[209.132.176.4]: NTPServer[1]=[64.22.86.210]: NTPServer[2]=[]: NTPServer[3]=[]: NTPServer[4]=[]: Use Network Time Protocol(NTP)=[y]: eth0 Network Configuration enable0=[0]: ipaddr0=[dhcp]: netmask0=[0.0.0.0]: broadcast0=[0.0.0.0]: gateway0=[0.0.0.0]: nameserver0=[0.0.0.0]: hwaddr0=[00:08:2b:00:11:22]: MTU0=[1500]: eth1 Network Configuration enable1=[0]: ipaddr1=[dhcp]: netmask1=[0.0.0.0]: broadcast1=[0.0.0.0]: gateway1=[0.0.0.0]: nameserver1=[0.0.0.0]: hwaddr1=[00:08:2b:00:11:23]: MTU1=[1500]: eth2 Network Configuration enable2=[1]: ipaddr2=[192.168.1.211]: netmask2=[255.255.255.0]: broadcast2=[192.168.1.255]: gateway2=[192.168.1.1]: nameserver2=[192.168.1.10]: hwaddr2=[00:08:2b:00:11:24]: MTU2=[1500]: eth3 Network Configuration enable3=[0]: ipaddr3=[dhcp]: netmask3=[0.0.0.0]: broadcast3=[0.0.0.0]: gateway3=[0.0.0.0]: nameserver3=[0.0.0.0]: hwaddr3=[00:08:2b:00:11:25]: MTU3=[9000]: eth4 Network Configuration enable4=[0]: ipaddr4=[dhcp]: netmask4=[0.0.0.0]: broadcast4=[0.0.0.0]: gateway4=[0.0.0.0]: nameserver4=[0.0.0.0]: hwaddr4=[00:08:2b:00:11:26]: MTU4=[9000]: Change Network Settings? [n]:

At this point the user may inspect the list. If the user wishes to modify any of the listed values, enter ‘y’ at the above prompt. The configuration utility will then display each parameter, one at a time. The user may accept the default input by pressing the ENTER key, or enter a replacement value. In the example below, the user will change the Hostname for the blade. Change Network Settings? [n]: y System Identification and TimeZone Active Settings 0: Hostname=[BladeHost]: STOR200 Changing Hostname= from Emerson1 to STOR200 1: DomainName=[Emerson.com]: 2: Date=[12/19/2007]: ... 48: enable4=[1]: 49: dhcp4=[0]: 50: ipaddr4=[192.168.44.11]: 51: netmask4=[255.255.255.0]: 52: broadcast4=[192.168.44.255]: 53: gateway4=[192.168.44.1]: 54: hwaddr4=[00:11:0D:D0:08:04]: 55: MTU4=[9000]:
In the previous example, the user elected to change the hostname from Emerson1 to STOR200. Also note, the tool prints a index number preceding each parameter. Hit the Enter key to proceed through the rest of the list. After displaying the final parameter, the configuration tool presents the user with two questions: Save New Network Settings? [y]: n Change Network Settings? [n]: n
Configuration tool question Possible responses
Save New Network Settings? y, changes are immediately applied, and all changes are stored in non-volatile ram flash device. This action ensures the changes are remembered after reboot.
n, do not store changes in NVRAM
Change Network Settings? y, changes are immediately applied, but new values are NOT stored in non- volatile flash device. They will revert to previous stored on rebbot.
n, discard the changes, and return to the main menu.
The “atca_blade” tool supports scripted invocations, to apply a fixed set of parameter values from a file. Such files would contain a pre-determined set of

responses that are applied to the tool in a macro fashion. A script allows the user to modify one or several parameters in one step.
SYNOPSIS atca_blade menu_page_index index_skip+ new_value [+ ] [+]
atca_blade may be called via shell script or batch file to make “un- manned” changes to parameter values used to configure ATCA-S201 IP and RAID service behaviors.
OPTIONS menu_page_index: designates the menu subgroup to be modified. The menu sub- group numbers are displayed when the tool is manually invoked with no arguments from the console window. The menu_group_number and index_skip are combined to create a pointer to a specific parameter position. The following menu_page_index syntax may be used interchangeably:
1|get_status 2|set_network 3|set_raid 4|set_lvm2 5|set_ms 6|set_smb 7|set_nfs 8|set_iscsi 9|set_gui 10|set_useroverride
y|n: Certain commands require affirmation to make changes. Example: ”Change Network Settings? [n]:”.
index_skip+: represents index leap ahead. The tool parses this value, and increments the index pointer by the amount indicated.
+: end of input (a plus symbol, with no integer). Indicates that the input line is complete, and requested changes can be committed.
Example #1: Use this script entry to change the blades Hostname. atca_blade set_network Y 0+ StorageBlade_99 +
Example #2: Additional references.
Specific CLI usage and syntax examples are provided within each configuration chapter of this manual.
In some deployments, a DHCP server may not exist. In these instances the blades Ethernet resources will require manual initialization.
Menu_page_index|equivalent_pagename

The ATCA-S201 employs a staged boot process that begins with U-boot. U-boot is an open source boot loader program that is the first code executed at system reset. As the boot execution commences, its progress may be monitored via the RS232 console port of the Advanced RTM. U-boot supplies several initialization parameters to the Linux kernel that administrators may elect to modify. U-boot employs a countdown timer with a default setting of bootdelay seconds, see table below. If a key is pressed before this time, the auto boot procedure halts and the administrator will see a U-Boot command prompt: ... Hit any key to stop autoboot: 5 uboot=>
Users may never need the U-boot environment. U-boot is included to accommodate atypical system maintenance situations such as:
On site field servicing (must be connected via serial console) Network boot (rather than flash boot) Environments without a DHCP server Flash recovery
The U-boot console environment includes a rich set of commands that can be listed on the screen using the following command: uboot=> help
Typically, only a handful of commands are needed to configure a new ATCA-S201. The essential commands are covered in the table below.
Table 8 Essential U-boot configuration commands
U-boot command syntax description
printenv Displays a list of all U-boot environment variables and their current values. See section 3.6.3 for details.
setenv
Used to create or modify a U-boot environment variable. New variables will be automatically created, existing ones overwritten. When called without a <new value>, it will delete the matching <variable_name> from the U-boot environment if it exists.
saveenv Used to saves environment variables to flash device, which is loaded upon subsequent system power cycle or reboot.
Variable changes that are not saved exist in RAM only,

U-boot command syntax description
and lost if the system is re-booted.
ping Sends an icmp echo address to the designated IP address (entered in dotted decimal format)
reset Perform soft reset of the ATCA cpu, forcing a system reboot.
run Run a sequence of commands defined in the environment <variable_name>, for example:
version Displays the version and build date of the U-boot image running on ATCA blade.
Administrators may display the full list of environment variables using the printenv command. U-boot includes the following environment variables with pre-assigned factory default settings.
Table 9 U-boot environment variables shown with printenv Variable name Default value Description bootcmd run flashboot This variable defines a command string that is automatically executed when the initial bootdelay countdown is not interrupted. flashboot A sequence of commands, set at manufacturing time. If in the U-boot console, use run flashboot to boot the ATCA using the images contained in flash. This command sequence is executed automatically by bootcmd in a normal power-up. ramboot A sequence of commands, set at manufacturing time. If in the U-boot console, use run ramboot to boot the ATCA from the serverip node. nfsboot A series of startup commands, set at manufacturing time. RESERVED for future use. bootdelay 5 U-boot will wait this number of seconds before it executes the bootcmd variable. After reset, a countdown message is printed to the serial console. Pressing any key will interrupt normal boot and display the U-boot console prompt. Value 0 =boot without delay. Value -1 = disable autoboot, always enter U-boot console baudrate 115200 RS232 Serial port baud rate, default=115200 (decimal) (Max: 115200) loads_echo 1 If set to 1, all characters received during a serial download (using the loads command) are echoed to the serial console. rootpath /nfsroot RESERVED for future use. hostname Not used
uboot=> run flashboot

Variable name Default value Description bootfile Uimage This is the filename name of the Linux kernel image. loadaddr 1000000 Specifies the starting memory address for storing the bootfile consoledev ttyS1 Settings for kernel console port. bootargs root=/dev/ram rw ramdisk_size=200000 console=ttyS1,9600
Command line passed to the Linux kernel. May contain nested references, which will be resolved at runtime.
Ramdiskaddr 2000000 Specifies the starting memory address of the Linux ramdisk. ramdisksize 2000000 Specifies the memory size reserved for the Linux ramdisk. initrd_high 0xfffffff Forces ramdisk to load at a high memory address (do not modify) othbootargs Used to pass Ethernet MAC and SAS address assignments to Linux. ramdiskfile rootfs.ext2.gz.uboot Specifies name of rfs (root file system) image fetched by U-boot when booting from the tftp server (serverip). eth0addr 00:11:0D:xx:xx:xx MAC address of 1 GbE port on ATCA Zone-2 base-0 eth1addr 00:11:0D:xx:xx:xx MAC address of 1 GbE port on ATCA Zone-2 base-1 eth2addr 00:11:0D:xx:xx:xx MAC address of 1 GbE port on ATCA Zone-3 Management port eth3addr 00:11:0D:xx:xx:xx MAC address of 10 GbE port on ATCA Zone-2 fabric-0 eth4addr 00:11:0D:xx:xx:xx MAC address of 10 GbE port on ATCA Zone-2 fabric-1 sasaddr 50:00:00:11:OD:xx:xx:xx WWN address of SAS controller, port0. Port 1 is WWN+1, Port2 is WWN+2 and so on. ipaddr 0.0.0.0 Dotted decimal IP address applied to active Ethernet management port (ethact) gatewayip 0.0.0.0 Dotted decimal Default network gateway netmask 0.0.0.0 Dotted decimal network mask stdin serial Specifies RS232 console port for input messages stdout serial Specifies RS232 console port for output messages stderr serial Specifies RS232 console port for error messages serverip 0.0.0.0 Dotted decimal IP address of TFTP server ethact At boot, ethprime is copied to ethact.
Ethact identifies which Ethernet resource is associated with U-boot services. Permissible values: eTSEC0= Zone2 connector, Base0 Ethernet (1Gbps) eTSEC1= Zone2 connector, Base1 Ethernet (1Gbps) eTSEC2= Zone3 connector, Management port (1Gbps) Note: ethact may be dynamically changed at the U-boot console, but it is not a persistent variable, and will be reloaded at next boot. netdev eth2 RESERVED for future use ethprime eTSEC2 At boot, ethprime is copied to ethact. Refer to ethact for a list of permissible values.
Administrators may individually modify any of the listed U-boot environment variables. Note these changes are not permanently recorded in the non-volatile flash unless saved using saveenv. Extreme care should be taken to ensure new values are valid entries.

To manually establish IP port address, a typical new system configuration might consist of the following commands: uboot=> setenv ipaddr 192.168.1.211 uboot=> setenv gatewayip 192.168.10.1 uboot=> setenv netmask 255.255.255.0 uboot=> setenv ethprime eTSEC2
Once all of the environment variables have been modified they persist only if permanently recorded in the flash device. This is accomplished with this command: uboot=> saveenv
This example setup establishes initializes the 1Gb Ethernet port located on the RTM for administrator login and management access.
The ATCA-S201 supports network boot which allows the user to bypass code contained on the embedded flash devices, and instead load code images contained on the network. Network boot does not replace stored user configurations. Network boot requires that the network node supports tftp and must contain the following source files located in directory named /tftpboot/:
U-boot.bin uImage Rootfs.ext.gz.uboot
... Hit any key to stop autoboot: 5 uboot=> run ramboot

Ethernet Comm. Setup
NFS / SMB Share Setup
This chapter explains how to configure the IP ports for external host access. The ATCA-S201 offers 5 Ethernet ports within the ATCA environment, as follows:
Two 10Gb XAUI fabric ports (zone-2) Two 1Gb base ports (zone-2) One 1Gb management port (zone-3)
IP host 1:1 mapping (JBOD)
1:1 mapping (JBOD)
Storage is ultimately served out over these IP ports using iSCSI, NFS and SMB protocols. Administrators may individually enable and configure these ports. Configuration can be done using the serial console port, Telnet or via HTML. This chapter assumes the reader is familiar with internet protocols and TCP/IP networking.

The web browser configuration tool may be enabled or disabled for security reasons.
Table 10 CLI command syntax, enable/disable GUI access Convention atca_blade set_gui + < enable> 0|1 Value 0 disables the GUI, value 1 enables the GUI.
The user may perform HTML configuration with any browser that supports https . Direct your browser to the any active IP port on the ATCA-S201. The ATCA-S201 employs https (encrypted secure sockets layer- SSL) technology to protect configuration activity that occurs over IP links. The ATCA-S201 issues a self-signed certificate, identified as “EMERSON”. This certificate is not registered with a certificate authority, and the browser will pop up a warning as shown below. Users must accept the certificate to proceed.




A user login is required to access and operate the ATCA-S201 storage blade. This menu prompts the user for username and password. When shipped from the factory, the default entries are username=admin, password=admin. See section 3.2.1for the information on the Password change procedure.
StorBlade99 ATCA-S201 Enter Username and Password
Username:
Password:
CLI command syntax · Submit

The system will automatically terminate (logout) a remote user after 10 minutes of in-activity. Optionally, the user can create this file to set an alternate inactivity threshold value (expressed in seconds):
A local user may immediately terminate an active management session by deleting the following file:
The above command will require the remote user to re-login, or allow the administrator to launch the atca_blade CLI tool locally.
Blade management is restricted to one admin user at a time, thus preventing blade configuration conflicts from multiple remote locations. Moreover, a user may not simultaneously operate the atca_blade CLI tool with the web GUI configuration tool.
Users may optionally override this protection mechanism using either of the following mechanisms:
Refer to page 55, Table 24 ATCA status indication, for the instructions to enable this override “Allow GUI and CLI”.
Table 11 CLI command syntax, single session management override Convention atca_blade set_useroverride <enable> +
< enable> 0|1 Value 0 disables the GUI, value 1 enables the GUI.
Once logged in, the user will see the start-up screen shown in the figure below. Left click the folder panel to expand the menu configuration tools.

Web GUI command · CLI command syntax · Emerson ATCA-S201 +








Figure 8 HTML tool, startup screen
Once connected to html configuration page, it is essential that the user navigate to both the Network and Shelf configuration pages. Proper interaction with the blade cannot occur without completing these configuration steps:


iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance Network Shelf I/O Status CPU Status ATCA Status
Submit All Network Changes Add New VLAN VLAN Index Interface
HostName DomainName Date Time TimeZone Nameservers NTP Server List Use NTP
Active Settings StorBlade99 domain.com 4/6/2009 08:51:59 New_York 0.0.0.0 tick.usask.ca tock.usask.ca y
IPAddress Network Mask Broadcast Gateway MTU Size MAC Address
IPAddress Network Mask Broadcast Gateway MTU Size MAC Address
IPAddress Network Mask Broadcast Gateway MTU Size MAC Address
New Settings DHCP Enable dhcp 1500 0.0.0.0 0.0.0.0 0.0.0.0
IPAddress Network Mask Broadcast Gateway MTU Size MAC Address
New Settings DHCP Enable 192.168.43.11 9000 192.168.43.255 255.255.255.0 192.168.43.1
IPAddress Network Mask Broadcast Gateway MTU Size MAC Address
New Settings DHCP Enable 192.168.44.11 9000 192.168.43.255 255.255.255.0 192.168.44.1
Figure 9 Emerson ATCA-S201 Maintenance Network
Use the mouse to navigate and make changes to an item in the “new settings” row. Notice that changes made here do not immediately change the “Active settings” row. New settings changes are abandoned by navigating away from the page. Changes are committed only when the “submit” button is clicked.
The attributes in this menu grouping establish time reference utilized by all aspects of product operation.
Submit

System Identification and TimeZone
HostName DomainName Date Time TimeZone Nameservers NTP Server List Use NTP
Active Settings StorBlade99 domain.com 4/6/2009 08:51:59 New_York 0.0.0.0 tick.usask.ca tock.usask.ca y
New Settings NTP StorBlade99 domain.com tick.usask.ca 4/6/2009 08:51:59 New_York
4.6.1 Hostname
The user may assign a human friendly name to the ATCA-S201 instance. The hostname is printed at the top of all menus, and listed in configuration and logs files. Users are encouraged to assign different hostnames to each blade; however there is no actual requirement to make unique assignments within a namespace.
Table 12 CLI command syntax, set network property: hostname Convention atca_blade set_network Y 0+ <hostname> +
< hostname> Any combination of letters or digits, no spaces
The user may use this field to specify the registered domain name in which the product will operate (e.g. emerson.com or example.net). In practice, this name should be officially assigned and recorded with the domain name registrar.
Table 13 CLI command syntax, set network property: domain name Convention atca_blade set_network Y 1+ <domain> +
Argument represents new domain name, e.g. yourdomain.com
The user may manually adjust the system date, if NTP is NOT enabled. Date must be entered as month/day/year. (e.g. 3/15/2008).
CLI command syntax · CLI command syntax

Table 14 CLI command syntax, set network property: system date Convention atca_blade set_network Y 2+ <date> +
Date format MM/DD/YYYY, (month,day,year)
The user may manually adjust the system time, if NTP is NOT enabled. Date must be entered as hours/minutes/seconds. (e.g. 14:51:59 to indicate 2:51 PM and 59 seconds).
Table 15 CLI command syntax, set network property: system time Convention: atca_blade set_network Y 3+ <time> +
hh:mm:ss (for example, 01:23:45), where hh (00 to 23), mm and ss (00 to 59)
World Time references are synchronized with GMT. The drop-down time zone field allows the user to choose a city matching the physical deployment region and daylight savings observance. To minimize code size, only one city per world time zone was chosen. The valid list of drop down field are shown in Table 17 Time Zone Selections.
Table 16 CLI command syntax, set network property: system time zone Convention: atca_blade set_network Y 4+ <zone> +
Pick from list in Table 17 Time Zone Selections. E.g. New_York, Chicago etc.
CLI command syntax · CLI command syntax · CLI command syntax

Table 17 Time Zone Selections

London WET -Western European GMT+1 Paris CET — Central European GMT-1 GMT+2 Athens EET — Eastern European GMT-2 GMT+3 Moscow BT - Baghdad GMT-3 St_Johns GMT+4 GMT-4 Halifax AST - Atlantic Standard GMT+5 GMT-5 New_York EST — Eastern Standard GMT+6 GMT-6 Chicago CST — Central Standard Denver MST - Mountain Standard GMT+7 GMT-7
Phoenix GMT+8 Taipei CCT — China Coast GMT-8 Los_Angeles PST — Pacific standard GMT+9 Tokyo JST — Japan Standard GMT-9 Anchorage YST — Yukon Standard GMT+10 Sydney GST — Guam Standard GMT- 10 Honolulu HST - Hawaiian Standard
Name servers must be specified using dotted decimal notation. For redundancy purposes, the user may specify up to five servers, each separated by a comma.
Table 18 CLI command syntax, set network property: assign Name server Convention: atca_blade set_network Y 5+ <server1> … [server5]+
Enter one to five name servers, specified as Dotted decimal addresses.
NTP servers must be specified using dotted decimal notation. For redundancy purposes, the user may specify multiple servers, each separated by a comma. At manufacturing time, this field is seeded with two NTP servers:
64.22.86.210 209.132.176.4
CLI command syntax · …

Table 19 CLI command syntax, set network property: assign NTP server Convention: atca_blade set_network Y 10+ <server1> … [server5]+
Enter one to five NTP servers, specified as Dotted decimal or domain addresses (time.nist.gov)
Users may enable NTP protocol service to synchronize the ATCA- S201’s clocks with a known good reference time source.
The ATCA-S201 provides multiple Ethernet interfaces that host blades may use to access storage. Whether using the CLI or web based configuration tools, these ports are identified with the Linux resource labels shown in the table below
Table 20 Ethernet ports for chassis communications (base/fabric) Linux interface identifier Port Description /dev/eth0 10/100/1000 — Base 0 (Zone -2) /dev/eth1 10/100/1000 — Base 1 (Zone -2) /dev/eth2 10/100/1000 — Management (RTM, Rear I/O management port) /dev/eth3 10G — Fabric 0 (Zone-2 XAUI ) /dev/eth4 10G — Fabric 1 (Zone-2 XAUI )
The webtool provides a table for each Ethernet resource. Users may enter new settings for any field, and click the submit button located at the top of the screen to apply the settings.
IPAddress Network Mask Broadcast Gateway MTU Size MAC Address
Active Settings 192.168.200.32 255.255.255.0 192.168.200.255 192.168.200.1 1500 00:11:0D:xx:xx:xx
New Settings DHCP Enable dhcp 1500 0.0.0.0 0.0.0.0 0.0.0.0
CLI command syntax · … · Management[eth#] Network configuration

Table 21 CLI command syntax, set network property: Ethernet port configuration Convention: atca_blade set_network Y + Use portcode 16+ to modify eth0
Use portcode 24+ to modify eth1 Use portcode 32+ to modify eth2 Use portcode 40+ to modify eth3 Use portcode 48+ to modify eth4 Use portcode 52+ to modify VLAN 0|1 Value 0 disables the port, value 1 enables the port. 0|1 Value 0 disables dhcp, value 1 enables the dhcp. When enabled, other network input fields are ignored. (ipaddr, netmask etc.) Remaining
ipaddr, netmask input formats etc. are defined in the sections below
The user may set a port online or offline with this menu box. When enabled the port in online, and will terminate IP traffic. When the port is disabled, IP packets are not processed.
The user may configure any port for Dynamic Host Configuration Protocol (DHCP). If DHCP is enabled, the port will search for a DHCP server to automatically set the IP address, subnet mask, default gateway address.
The user may manually assign the IP address of a port, if DHCP is NOT enabled. The address must be entered using dotted decimal notation. (e.g. 192.168.1.211)
The user may manually assign the subnet mask of a port, if DHCP is NOT enabled. The subnet mask must be entered using dotted decimal notation. (e.g. 255.255.255.0)
CLI command syntax · inputs

< Read/Write > The user may manually assign the broadcast address for a port, if DHCP is NOT enabled. The broadcast address must be entered using dotted decimal notation. (e.g. 192.168.1.255)
The user may manually assign the default gateway for a port, if DHCP is NOT enabled. The default gateway must be entered using dotted decimal notation. (e.g. 192.168.1.1)
The MTU defaults to 1500 bytes on each IP interface, but the user can adjusted higher if that size that is also supported by all adapter, switch, and router devices in the path. Any path component with a smaller MTU will break packets into pieces (fragment), which can reduce overall system performance. The user may specify the MTU (Maximum Transmission Unit) for each Ethernet resource. Linux interface Port Description Max MTU size /dev/eth0 10/100/1000 — Base 0 (Zone -2) 9586 /dev/eth1 10/100/1000 — Base 1 (Zone -2) 9586 /dev/eth2 10/100/1000 — Management (RTM port) 9586 /dev/eth3 10G — Fabric 0 (Zone-2 XAUI ) 16110 /dev/eth4 10G — Fabric 1 (Zone-2 XAUI ) 16110
MTU defines the maximum size of a packet that the blade may transmit over the network interface without fragmentation. A large MTU permits the system to send fewer packets of a larger size to achieve the same network throughput, with generally less OS and software overhead.
If you are not sure, you can often find the MTU size using a trial-and-error ping command. First set the MTU to the max, then open a console port, and ping the destination port, incrementing the size until no response is received:
ping 192.168.1.10 –l 1500 –f ping 192.168.1.10 –l 4000 –f ping 192.168.1.10 –l 8000 –f … ping 192.168.1.10 –l 16110 –f
The Ethernet MAC address is a 48-bit number that identifies the physical source and destination of the Ethernet 802.3 frame. The address is assigned by Emerson during manufacturing, and permanently recorded in nonvolatile memory on the blade.

Users may configure assign any of the Ethernet ports available on the ATCA-S201 to a Virtual Local Area Networking (Virtual LAN, IEEE 802.1q).
The webtool provides a entry for to define new VLAN. Users choose a physical interface from the drop down menu (etho, eth1..eth4) and assign a VLAN index. Click the submit button to apply the settings.
StorBlade99 ATCA-S201 Network Configuration
Submit All Network Changes Add New VLAN VLAN Index Interface
Users may also configure VLANs using a console window and the Linux vconfig tool.
vconfig offers a rich set of feature options. The section below explains only the minimal options to add or remove a VLAN definition. Consult the Linux manpages for more details.
SYNOPSIS vconfig [add|rem] [options]
vconfig is a program which enables the user to create and remove vlan devices.
OPTIONS add [interface-name] [vlan-id]
Creates a vlan-device on [interface-name]. The resulting vlan-device will be
called according to the naming convention set. Users should avoid using [vlan-id]= 1. Many hardware products use [vlan-id] 1 as the management vlan. See linux manpage ‘vconfig’ for more information.
Removes the named vlan-device.
# vconfig add eth4 66 # ifconfig eth4.66 up Finally, enable the VLAN, and commit to system flash memory:

Convention: atca_blade set_network Y Use VLANindex 52+ to modify 1st VLAN definition
Use VLANindex 60+ to modify 2nd VLAN definition Use VLANindex 68+ to modify 3rd VLAN definition Increment index by 8 for each additional VLAN definition 0|1 Value 0 disables the port, value 1 enables the port. Other prompts Other prompts will follow.
Disable the VLAN port (see notes above for explanation of )
# atca_blade set_network Y <VLANindex> 0 + # vconfig rem eth4.66 Permanently remove VLAN port from system flash memory. Edit file to remove 12 lines for VLAN entry # vi /etc/network.conf
Example: remove these 12 lines: # net interface 6 ifconfig eth4 up if [ `grep eth4.66: /proc/net/dev -c` -ne 1 ]; then vconfig add eth4 66 ; fi HWADDR[6]="" SYSCFG_IFACE[6]=y INTERFACE[6]="eth4.66" IPADDR[6]="5.5.5.5" NETMASK[6]="255.255.255.0" BROADCAST[6]="4.4.4.255" GATEWAY[6]="0.0.0.0" MTU[6]="1500" IF_NAME[6]="VLAN Network Port 6"
Each VLAN is enumerated within the management web-tool and CLI tools. Open the network page. Each VLAN appears as Port Description [eth#].[vlan-id] Network Configuration

The ATCA-S201 supports 802.3ad link aggregation also known as “bonding”. Bonding allows you to aggregate multiple Ethernet ports into a single group, effectively combining the bandwidth into a single connection. For example, you can aggregate the ATCA base channel ports (1 Gb/s each) into a trunk group, providing 2Gb/s cumulative bandwidth, fault tolerance and load balancing.


Base channel bonding example
Host Blade
The Linux bonding driver provides the ability to group ports, detect link failures and reroute traffic to the surviving ports in a manner transparent to the storage participants.
Figure 10 Link aggregation 802.3ad (bonding), theory of operation

The Linux community has created an extensive man page for ifenslave. The subset of essential elements is summarized below.
Deactivate the Ethernet “slave” ports that will become bond members Step2: modprobe bonding mode=0 miimon=100
This loads the bonding module, sets the usage policy mode and sets polling frequency to 100mS. Several mode exist, but these are the most common Valid mode=[ ] options:. mode=0 - Round robin packet, or balanced transmit policy. This mode will only work with switches that support trunking.
mode=1- Active-backup; one slave port is active, the other is passive. This mode should work with any Layer-II switch.
Preserve new bond attributes
This file contains a template for adding commands that will be executed on boot (or shutdown) as required by the user. This file is stored in system flash memory and preserved over reboots. Edit this file and add the entire sequence of bond commands.
Example:
ifconfig eth0 down; ifconfig eth1 down modprobe bonding mode=0 miimon=100 ifconfig bond0 <ip-address> up ifenslave bond0 eth0; ifenslave bond0 eth1 eth1
Remove the relevant bond creation code, and reboot
Create new bond · Remove bond

Use these menus to initialize a communication path with the chassis shelf manager, and properly monitor ATCA-S201 hardware.
iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance Network Shelf I/O Status CPU Status ATCA Status
Blade 1 (Primary) Configuration
Blade Number IPMB‐Address (Hex)
Active Settings 1 0x96
Blade 2 (Expander) Configuration
Shelf Address
Shelf Primary Address Shelf Alternate Address
Active Settings 192.168.100.32 127.0.0.1
New Settings
192.68.100.32 127.0.0.1
Active Settings 2 0x84
New Settings 2
Figure 11 HTML tool, Emerson ATCA-S201 MaintenanceShelf

Table 22 Shelf configuration menu parameters
Shelf Address Primary/Secondary Address
Active Settings Current IP address of chassis shelf manager New Settings This field is used to assign a new IP address for the chassis shelf manager. User must hit “submit” to update the value.
Blade 1 Configuration IPMB-Address (Hex) for ATCA-S201
Active Settings Slot number and Hex address code corresponds to the physical slot where the ATCA-S201 blade is installed. The value is self-discovered, where Slot0=0x82, Slot1=0x84 … Slot13=0x9C, Slot14=9E
Blade 2 Configuration IPMB-Address (Hex) for slave expansion blade
Active Settings The ATCA-S201A may be paired with companion blade to add additional hardware resources such as additional hard drives Supported companion blades include the Emerson ATCA1020 JBOD and ATCA1010 PCIe expansion blades. This Hex address code corresponds to the physical slot where the companion blade is installed. Slot0=0x82, Slot1=0x84 … Slot13=0x9C, Slot14=9E. New Settings This field is used to assign a slot address for the blade. User must hit “submit” to update the value.
The items in this menu provide real-time information about the I/O activity occurring on physical disks connected to the ATCA-S201 raid controller. Disks may reside in any of the four AMC slots, RTM, or expansion JBOD products. Disks are identified by the Linux device designation /dev/sdx, highlighted in gray.

Maintenance Network Shelf I/O Status CPU Status ATCA Status
/dev/sda Current I/Os / sec Current MBytes / sec Total MBytes
/dev/sdb Current I/Os / sec Current MBytes / sec Total MBytes
Figure 12 HTML tool, Emerson ATCA-S201 MaintenanceIO Status
Status item Description

Table 23 Blade, I/O Status indication

Current I/Os / sec Bar graphs provided for each disk
Read Displays the number of real-time read I/O per second (read IOPS). Write Displays the number of real-time write I/O per second (write IOPS). Total Displays the cumulative number of real-time I/O activity (read and write).
Counter Mbytes / sec Numeric counters provided for each disk
Total Displays the cumlative real-time bandwidth, displayed megabytes/second Total Mbytes Numeric counters provided for each disk
Read/write/Total 128 bit counter displays the number of bytes transferred since reset.
These menus provide several miscellaneous operations that are useful for blade management and monitoring. The base page lists detailed versioning information of the loaded software as shown below:

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

Linux 2.6.23 #28 Wed Jul 1 09:09:29 EDT 2009

The physical disk assignments change as disks become utilized in a RAID definitions. Use the “Re-Draw Tree” button to rescan for physical disks, and refresh the menu view.
The button will issue a software-reset signal to the embedded SAS controller. If users have hot-swapped many disks, this ensures the SAS controller has completely purged internal tables, and is properly presenting the new or remaining disks to the operating system.
Software reset SAS controller
This button will reset all I/O status counters.
Rescan SAS topology

This screen displays real-time statistics for the applications running on ATCA-S201’s PowerPC processor. The data on this screen is derived from the Linux top command (man top), formatted to fit the HTML window. The screen auto refreshes approximately every 6 seconds.
StorBlade99 ATCA-S201 Current CPU Status top - 13:27:48 up 21:05, 1 user, load average: 0.03, 0.02, 0.00 Tasks: 61 total, 1 running, 60 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 1034688k total, 228964k used, 805724k free, 185084k buffers Swap: 0k total, 0k used, 0k free, 14496k cached
iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance Network Shelf I/O Status CPU Status ATCA Status
PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 17888 root 20 0 2456 1136 916 R 1.0 0.1 0:00.02 top 1 root 20 0 3876 808 680 S 0.0 0.1 0:07.44 init 2 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kthreadd 3 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 ksoftirqd/0 4 root 15 ‐5 0 0 0 S 0.0 0.0 0:09.15 events/0 5 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.01 khelper 69 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kblockd/0 76 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 ata/0 77 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 ata_aux 126 root 20 S 0.0 0.0 0:00.00 pdflush 127 root 20 S 0.0 0.0 0:00.34 pdflush 128 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kswapd0 129 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 aio/0 130 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 cifsoplockd 131 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 cifsdnotifyd 132 root 20 S 0.0 0.0 0:00.02 crypto 133 root 20 S 0.0 0.0 0:00.00 crypto_ret 163 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 pciehpd 496 root 20 0 7080 2032 1692 S 0.0 0.2 0:00.30 sshd 500 root 20 0 2668 1356 1132 S 0.0 0.1 0:00.01 sh 830 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 rpciod/0 851 root 20 0 3876 628 500 S 0.0 0.1 0:00.02 klogd
874 root 30 10 S 0.0 0.0 0:00.00 jffs2_gcd_m
877 root 30 10 S 0.0 0.0 0:00.54 jffs2_gcd_m
td0 894 root 16 ‐4 1788 560 484 S 0.0 0.1 0:00.04 udevd 956 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.20 mpt_poll_0 960 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.01 mpt/0 972 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 scsi_eh_0 1351 root 20 0 3876 628 504 S 0.0 0.1 0:00.36 syslogd 1440 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kjournald
Figure 13 HTML tool, Emerson ATCA-S201 MaintenanceCPU Status

The items in this menu provide operational condition of the ATCA-S201 and the four AMC slots and RTM if installed.
Maintenance Network Shelf I/O Status CPU Status ATCA Status
StorBlade99 ATCA-S201 Blade 1 (0x96) Status
Vendor IANA ID Name HW Revision
H8 FW Revision IPMI Rev Model Serial
Emerson 65cd ATCA‐S201 0004 01.10 01.50 ATCA‐S201 100LYMMSSSS
AMC Site B1 (0x7a) Configuration Phy Num Type SAS Address Handle Parent Disk 00 SAS 5000cca000784c49 0009 0001 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B2 (0x7c) Configuration Phy Num Type SAS Address Handle Parent Disk 01 SAS 500000e016cbd032 000a 0002 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B3 (0x7e) Configuration Phy Num Type SAS Address Handle Parent Disk 02 SAS 5000c50005b18665 000b 0003 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B4 (0x80) Configuration Phy Num Type SAS Address Handle Parent Disk 03 SAS 500000e016cbd982 000c 0004 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B5 (0x8e) Configuration Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson RTM 0106828G 401NYMxxx Enabled True Site Control
Figure 14 HTML tool, Emerson ATCA-S201 MaintenanceATCA Status

Table 24 ATCA status indication
PCI state Collection of values pertaining to AMC modules with PCI devices
Vendor 4 digit Hex value representing the PCI Vendor ID . Device 4 digit Hex value representing the PCI device ID . SVID 4 digit Hex value representing the PCI sub-system vendor ID . (set to 0000 for non-PCI modules) SSID 4 digit Hex value representing the PCI sub-system device ID . (set to 0000 for non-PCI modules) Bus/Slot/Func Displays the OS assignments for bus, slot, and function of the PCIe device. (set to 0000 for non-PCI modules)
AMC state Collection of values pertaining to AMC modules with PCI devices
Vendor FRU data retrieved from the management device; it indicates the manufacturer of the device. Product FRU data retrieved from the management device; it indicates the product name.
Model FRU data retrieved from the management device; it indicates the model name.
Serial FRU data retrieved from the management device; it indicates the serial number.
State Indicates whether the AMC module is enable or disabled.
Present Indicates the present pin is asserted, indicated the presence of a module
MgEna Indicates management enable is asserted on the AMC
MgOK Indicates management power is detected on the AMC
PayEna Indicates payload enable is asserted on the AMC
PayOK Indicates payload power is detected on the AMC
‘Radio button’ when selected will eliminate the majority of ‘pop-up’ confirmations that precede major configuration changes.
‘Radio button’ will allow an administrator to operate the GUI and CLI simultaneously.
Allow GUI and CLI
This button will redraw the display window.
This button will reboot the storage blade, and all storage served by this blade will be unavailable. The Blade will terminate all applications and shutdown its internal OS. The blade will automatically reboot, by executing the uboot, kernel and applications loaded in its flash memory.
This button will power down the storage blade, and all storage served by this blade will be unavailable. The Blade will terminate all applications and shutdown its internal OS. When the sequence completes all hot-swap LED indicators will illuminate “Blue”. Manual operator action will be required to reboot the blade.
This button will enable AMC sites. When enabled, the menu will show the AMC state as Enabled.
This button will disable AMC sites. When disabled, the menu will show the AMC state as Disabled.

Table 25 CLI command syntax, blade_status for ATCA and AMC site status Convention: atca_blade get_status 2 +
Display ATCA blade revision information Convention: atca_blade get_status 1 <site> +
1 |2|3|4|5 Display site status: 1=Site B1, 2=Site B2, 2=Site B3, 2=Site B4, 2=Site B5 (RTM)
CLI command syntax

Ethernet Comm. Setup
NFS / SMB Share Setup
This chapter explains how to prepare and configure RAID volumes that are ultimately mapped to the various IP services advertised on the ATCA-S201 ATCA carrier board. These virtual RAID volumes are created from in-chassis storage pools comprised of AMC modules with SAS or SATA disks. Hardware RAID services are available for disk striping (RAID0) and extended volume mirroring (RAID1, RAID1E). Software RAID services are available for parity based disk striping algorithms including RAID4, RAID5 and RAID6. The Software RAID features of this product can provide better capacity utilization efficiency, but can consume a greater percentage of CPU and system memory bandwidth.
IP host 1:1 mapping (JBOD)
1:1 mapping (JBOD)
Administrators will use two inter-related menus to enable and configure the hardware RAID features of ATCA-S201. These configuration tools appear within the html tool’s main navigation panel on the left side as shown in the figure below.
Emerson ATCA-S201 Hardware RAID Emerson ATCA-S201 Physical Disks


Shares LVM2 LVM2 Configuration MD RAID Configuration Hardware RAID Configuration Physical Disks /dev/sda /dev/sdb /dev/sdc /dev/sdd /dev/sde /dev/sdf /dev/sdg Maintenance
Figure 15 HTML tool, Main navigation side-bar, Hardware RAID->Configuration
These menus are used to view and arrange the hardware disk pool. The hardware disk pool is the raw (unformatted/unassigned) disk capacity or resources available to a ATCA-S201. In SNIA terminology, these are primordial disks. This storage is block I/O comprised of the following:
The sum capacity of the hardware disk pool resources equals the total size of storage available to the particular ATCA-S201.
Just a bunch of disks (JBOD) is a term to describe disks which are not part of a RAID or logical device definition. By default, a new ATCA-S201 will scan and display all discovered disks 1:1 in the physical disk menu. These disks may be used as-is, or grouped using the configuration tools to create RAID or combined logical volumes.
On a new system installation, this configuration menu enables the creation of RAID disk(s) that will appear in the physical disk menu. Once created, RAID disks are managed in the same manner as other physical disks, but boast benefits including improved performance and redundancy.


Disk Name Parent Host Bus Target Lun Vendor Product Rev Size Select
1 /dev/sda md0 HITACHI HUC101414CSS300 A410 140205MB
2 /dev/sdb md0 0 0 1 0 HITACHI HUC101414CSS300 A410 140205MB
3 /dev/sdc unknown 0 0 2 0 HITACHI HUC101414CSS300 A410 140205MB
4 /dev/sdd unknown 0 0 3 0 FUJITSU MAY2073RC 0103 70136MB
Select 2 or more disks for Volume Raid 1/E Raid 0
Figure 16 Emerson ATCA-S201 Hardware RAID (new installation screen-shot)
Disk An enumeration of disks that may be used in new RAID LUN definition. Parent Identifies the volume that claims ownership to a disk. ‘Unknown’ indicates no volume ownership. Host/Bus/Target/Lun Identifies the SCSI parameters used to address the virtual RAID device Vendor/Product/Rev Use these items to identify the physical disk resource. Size Capacity of the disk Select “Radio button” used to select which disks will participate in the new RAID LUN definition RAID1/E Click to create a new RAID1 LUN (mirroring) RAID0 Click to create a new RAID0 LUN (stripping)
Click to commit the selections and create the new RAID device.
Table 26 CLI command syntax, set_raid: Add RAID configuration Convention: atca_blade set_raid Y <diskmask> <RAID_level> Y +

Ydisk|Ndisk … [Ydisk|Ndisk] variable length mask. Must specify one entry for each system disk. Ydisk includes disk in RAID volume, Ndisk exclude disk from RAID volume. 0|1 Use value 0 to apply RAID0, and value 1 to apply RAID1 atca_blade set_raid Y Ydisk Ydisk Ydisk Ndisk 1 Y + Syntax examples
System has four disks. Assign the first three disks to new RAID1 volume.

RAID Level RAID0 RAID1 RAID1E
Description Two or more disks are grouped to provide a capacity aggregation function. The advantage is the multiplicative performance and capacity effect of up to 10 spindles working in concert to store or retrieve data for the host.
Exactly two disks are grouped to provide a mirror function. By definition, two drives our bounded in a fashion such that every write to one drive is mirrored to the second. If a failure occurs with either drive, data is still accessible via the surviving drive.
Three or more disks are grouped to provide a mirror function using an algorithm extension to permit use with many drives. If a failure occurs with any drive, data is still accessible via the surviving drives.
S0 S1 S2 S3 S4
S0 S1 S2 S3 S4
RAID1
RAID1E
RAID0
S0 S1 S2 S3 S4 S4
S0 S0’ S1 S1’ S2 S2’
S0 S0’ S1’ S2 S3 S3’
S1 S2’ S4
Disk 1 Disk 2
Disk 1 Disk 2
Disk 1 Disk 2
The number of devices appearing in the Physical Disks menu will change once the user applies RAID services. The figure below illustrates this concept. In this example, there are four AMC disk modules available to the ATCA-S201, but only three disks appear in the physical disk menu.


Figure 17 Figure shows how RAID LUN definitions alter physical disk display
After creating a RAID volume, the RAID configuration tool page changes to include several new configuration options. The menu is now comprised of four sections, arranged to facilitate creation and deletion of RAID volumes and global hot spares.

Disk Bus Target Lun Vendor Product Rev Size Select
Select 2 or more disks for Volume Raid 1/E (Mirroring Extended) Raid 0 (Striping)
Volume Bus Target Type WWID State Status Size Stripe Size
Volume 0 0 6 Raid1 00ba23e977ca6eb7 optimal enabled 70008 0
Member Physdisk Errors Bus Target Lun Vendor Product Rev Size State
0 56 0 FUJITSU MAY2073RC 0103 70136MB online
1 1 0 0 9 0 SEAGATE ST9146803SS 0002 140014MB online
Available Disk Bus Target Lun Vendor Product Rev Size Select
Section 4
No Disks Have Been Allocated to Hot Spare Pools
Figure 18 Hardware RAID configuration screen showing existing RAID volume

Section 1 — Create RAID volumes
List of remaining disks available for new RAID volume definition. Click to select disk members. Click to select RAID level Click create Volume Upon completion, the physical disk view will change to display the new Virtual RAID volume while its disk members become hidden. Section 2 —RAID Status Summary
Provides a detailed status of existing RAID volumes, and details regarding the “hidden” disk members. Click “delete” to erase this volume and return all of the member disks to the pool of available disks. Section 3 — Allocate Hot Spare List of disks available for new global hot spare. The ATCA-S201 will use a global hot spare to repair a RAID1 or RAID1E volume that is degraded. Section 4- Hot spare status Provides a detailed status of existing global hot spares. Click “delete” to return a spare disk to the pool of available disks.
Understanding the Hardware RAID status table page
Once the RAID volume is created, the individual disks comprising a RAID disk are “hidden” from the OS and physical disk view, but are shown in the RAID status table.
Volume The ATCA blade is label string identifies the RAID volume. Bus/Target Identifies the SCSI parameters used to address the virtual RAID device Type Identifies the RAID level employed by the virtual RAID device. (Raid0, Raid1, or Raid1E) WWID The World-Wide Identification, is an eight byte SAS address that uniquely identifies the virtual RAID volume. Optimal — The RAID volume and all comprising disk members are fully operational Degraded - The RAID volume is accessible for read/write operation, but one of its underlying disk members is offline.
Failed - the RAID volume is not accessible for read/write operations. Data loss may have occurred. Enabled (default) — The RAID volume is able to receive I/O commands Status
Offline — The RAID volume cannot receive I/O Size The usable capacity, (MB) of the Virtual RAID drive. Stripe Size The maximum chunk of data that is written to one disk of a RAID group. The stripe width = Stripe size * number of disks. The ATCA- S201 currently applies a fixed size of 64 KB.

Administrators may use the ‘MD RAID’ menus to configure the Software AID features of ATCA-S201. The implementation leverages the mdadm tool available with the 2.6.23 Linux kernel, which also offers the ability to conduct all volume setup and configuration via a shell commands. Upon creation, a new software raid-device will appear as a new device in web or cli configuration menus. Users may utilize the new raid-device to create logical volumes, and configure iSCSI and NAS file shares. The ‘MD RAID’ configuration tool appears within the html tool’s main navigation panel on the left side as shown in the figure below.
On a new system installation, this configuration menu enables the creation of RAID disk(s) that will appear in the physical disk menu. Once created, RAID disks are managed in the same manner as other physical disks, but boast benefits including improved performance and redundancy.

iSCSI nfs smb Shares LVM2 MD RAID Configuration Hardware RAID Physical Disks Maintenance
Disk Parent Bus Target Lun Vendor Product Rev Size Select
/dev/sda Unknown 0 1 0 HITACHI HUC101414CSS300 A410 140205MB
/dev/sdb Unknown 0 2 0 HITACHI HUC101414CSS300 A410 140205MB
/dev/sdc Unknown 0 0 0 HITACHI HUC101414CSS300 A410 140205MB
Add to Volume RAID 0 RAID1 RAID 4 RAID 5 RAID 6 Override warnings
Figure 19 Emerson ATCA-S201 MD RAID (new installation screen-shot)
Available Disk An enumeration of disks that may be used in new RAID LUN definition. Parent Identifies the volume that claims ownership to a disk. ‘Unknown’ indicates disk has no known volume ownership. Bus/Target/Lun Identifies the SCSI parameters used to address the virtual RAID device Vendor/Product/Rev Use these items to identify the physical disk resource.
Select ‘Radio button’ identifies which disks will participate in the new RAID LUN definition.
Add to volume ‘Radio button’ adds the selected disk(s) to an existing volume as spare disk(s). If a volume is degraded, the volume will immediately commence a re-build operation.
RAID0 Click to create a new RAID0 LUN (stripping)
RAID1 Click to create a new RAID1 LUN (mirroring)
RAID4 Click to create a new RAID4 LUN (Fixed parity)
RAID5 Click to create a new RAID5 LUN (Rotating parity)
RAID6 Click to create a new RAID6 LUN (double parity)

ˇ Use this drop down menu to choose a volume name. Four choices: md0, md1,md2 or md3
Click to commit the selections and create the new RAID device.
Ignore Warnings ‘Radio button’ will ignore minor mdadm warnings. Example ignore warning when creating RAID1 with disks that have greater than 1% capacity difference. This Filed self-clears on each use.
Import Foreign Array Will display ONLY in situations when a drive contains meta-data that indicates it was at one time a member of a software RAID volume. Click and select participating drives to attempt an import of the volume.
Clear ownership Will display ONLY in situations when a drive contains meta-data that indicates it was at one time a member of a software RAID volume. Click and select drives to clear all meta-data stored on these disk(s). This operation will permanently eliminate the import array option.
Table 27 CLI command syntax, mdadm: manage RAID configuration
Create new volume mdadm –-create raiddevice –n <#devices> -l <raidlevel> [-c <stripe_size>] <component-devices> --create “Create” mode, used initialize a new md array, associate some devices with it, and activate the array. Raiddevice Device name assigned to new volume. Example /dev/md0. Integer, specifies the number of Integer: 4=raid4, 5=raid5, 6=raid6 Optional, will default to 64 if omitted, expressed in kilobytes. Within a stripe, this defines the ‘chunk’ of data read or written to any single member disk. Space delimited list of component devices. Example /dev/sda /dev/sdb…
mdadm --detail --scan > /etc/mdadm.conf
Preserve new volume attributes
Issue this command immediately after creating a new volume. This command preserves key volume parameters, and ensures the new volume is available across system reboots.
List volume status mdadm --detail --scan
Issue this command at any time to inspect volume status
Create hot spare mdadm –-add raiddevice <spare-device>
--add Used to add a spare disk to an existing raid-device. Users may issue this commend any number of times to specify multiple spare drives if available. Raiddevice Device name assigned to existing volume. Example /dev/md0 Designate spare device. Example /dev/sda
Remove faulty disk mdadm –-remove raiddevice <faulty-device>
md0 · Submit

--remove Used to remove a disk from a volume definition. Users may later re-add the disk using the —add command. Raiddevice Device name assigned to existing volume. Example /dev/md0 Designate faulty device. Example /dev/sda
Remove volume /etc/rc.d/init.d/mdarray stop

RAID Level Description Data Layout Diagram
RAID4 Three or more disks are grouped in fashion where all written data is available even when any single disk drive is removed or fails. RAID4 employs block level striping with a dedicated parity disk.
RAID4
S0 S1 S2 S3 S4 S4
Disk 1 Disk 2
RAID5 Three or more disks are grouped in fashion where all written data is available even when any single disk drive is removed or fails. RAID5 employs block level striping with a distributed parity disk. This provides a significant advantage for RAID5 vs RAID4 for write operations, because the bandwidth of all disks is available for parity write operations.
RAID5
S0 S1 S2 Parity Parity S4
RAID6 Four or more disks are grouped in fashion where all written data is available even when any two disk drives are removed or fail. RAID6 employs block level striping with two distributed parity disks. While RAID6 provides a significant redundancy advantage, each write spawns two additional parity calculations, which in turn adds commensurate loads on both the internal CPU and memory systems.
Disk 1 Disk 2
RAID6
S0 S1 S2 Parity-P Parity-P Parity-Q
S3 S5 Parity-Q S6 S7 Parity-P
Disk 1 Disk 2

Ethernet Comm. Setup
NFS / SMB Share Setup
This chapter explains how to prepare a device resource (example /dev/sda) for iSCSI or NAS file sharing. Disks appearing in the “physical disk” menu must first be mapped to a Logical Volume group before it can be used for these services. Once a device is committed as a shared resource for iSCSI or NAS for service, it becomes un-available for new RAID or logical volume definitions unless it is first un-shared.
IP host 1:1 mapping (JBOD)
1:1 mapping (JBOD)
A volume group is a group of one or more physical disks. A volume group gives the administrator several powerful tools to manage storage resources. These features include:
Define volume groups with multiple disks or partitions Dynamically increase a volume group by adding new physical disks
A volume group may be divided into multiple pieces. Each piece is known as logical device but may also be called a logical disk or volume. A Logical Device offers powerful features that include:
Essentially unlimited logical devices defined on each volume group Dynamically increase the size of logical device

Logical volumes are comprised of one or more physical disk members. Using the HTML configuration tool, the user may view the available set of physical disks.
Emerson ATCA-S201 Physical Disks
This top html menu provides a summary list of current physical disks.
StorBlade99 ATCA-S201 Physical Disk Summary
iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks /dev/sda /dev/sdb /dev/sdc Maintenance
Device Name Parent Device State Vendor Model Rev
/dev/sda Unknown Offline HITACHI HUC101414CSS300 A410
/dev/sdb Unknown Offline FUJITSU MAY2073RC 0103
/dev/sdc Unknown Offline LSILOGIC Logical Volume 3000
Update Java Menu to reflect added disks
Figure 20 HTML tool, Emerson ATCA-S201 Physical Disk (summary screen)
Physical disks resources can be mapped to logical volume groups, which are split into Logical device ‘slices’ which are then shared as iSCSI or NAS. The number of Physical disks may not necessarily correlate 1:1 with the hardware disk pool (e.g. number of AMC drive carriers), because physical disks may include volumes created through RAID services that mask the individual hardware disk members. From the ATCA-S201 perspective, physical disks are presented as Linux SCSI devices (/dev/sd[a-z]).
Online Device is actively used as either a iSCSI export or NAS share volume
Offline Device is available for iSCSI or NAS operations.

The physical disk assignments change as disks become utilized in a RAID definitions. Use the “Re-Draw Tree” button to rescan for physical disks, and refresh the menu view.
If the disk configuration is not displaying properly, users can rescan the SAS topology, using the button located on the Maintenance menu page.
If the disk configuration is not displaying properly, users can issue a software-reset signal to the embedded SAS controller using the button located on the Maintenance menu page. If users have hot-swapped many disks, this ensures the SAS controller has completely purged internal tables, and is properly presenting the new or remaining disks to the operating system.
Software reset SAS controller
Additional property informational is available for each physical disk. These may be viewed by clicking the individual device (e.g. /dev/sda), which opens the menu shown below.


iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks /dev/sda /dev/sdb /dev/sdc Maintenance

Name State Type Parent Host Bus Target LUN Vendor Model Rev
/dev/sda Online Raw Unknown 0 0 19 0 ATA 64G SATA Flash D 401A
Re‐Draw Tree · Rescan SAS topology

Table 21 HTML tool, Emerson ATCA-S201 Physical Disk (configuration screen)
Device Name Linux SCSI device name, from ATCA-S201 management perspective Online: indicates the device is active and ready for I/O State
file: indicates the device was formatted by the ATCA-S201 Parent Identifies the volume that claims ownership to a disk. ‘Unknown’ indicates disk has no known volume ownership. Host/Bus/Target/LUN Identifies the SCSI parameters used to address the physical device Vendor/model/Rev Identifies the vendor and revision of the disk device. If vendor = LSILogic, this physical device is a RAID volume managed by the ATCA- S201 resources.
A volume group must contain at least one physical disk member. The figure below outlines the steps that will be taken to create volume groups and logical device/disk volumes.

Shares LVM2 LVM2 Configuration MD RAID Configuration Hardware RAID Configuration Physical Disks /dev/sda /dev/sdb /dev/sdc /dev/sdd /dev/sde /dev/sdf /dev/sdg Maintenance
Figure 22 HTML tool, Main navigation side-bar, LVM2->Configuration
Logical volumes are comprised of one or more physical disk members. Using the HTML configuration tool, the user may view the available set of physical disks and assign them to volume groups.
Emerson ATCA-S201 LVM2 LVM2 Configuration
The screen shows physical disks which are available for a new volume group definition.
Parameter Description


iSCSI nfs smb Shares LVM2 LVM2 Configuration MD RAID Hardware RAID Physical Disks Maintenance
StorBlade99 ATCA-S201 Available Physical Disks
Group State Capacity File Type Vendor Model Rev Select
/dev/sda ‐none‐ Offline 140205(MBytes) Raw Unknown HITACHI HUC101414CSS300 A410
/dev/sdb ‐none‐ Offline 70136(MBytes) Raw Unknown FUJITSU MAY2073RC 0103
/dev/sdc ‐none‐ Offline 70008(MBytes) Raw Unknown LSILOGIC Logical Volume 3000
Select 1 or more disks for Volume Group
Figure 23 HTML tool, Emerson ATCA-S201 LVM2 Configuration
Follow these instructions to create a new volume group
group.

Table 28 CLI command syntax, create new volume groups Convention: atca_blade set_lvm2 Y Y Y + Ydisk |Ndisk … [Ydisk|Ndisk] variable length mask. Must specify one entry for each available system disk. Ydisk includes disk in new volume group, Ndisk exclude disk from new volume group. atca_blade set_lvm2 Y Ydisk Ndisk Y Y + Syntax examples
System has two disks. Assign the first disk to a new volume group.
Table 24 HTML tool, Emerson ATCA-S201 LVM2 logical group (status screen)
Volume/member Linux SCSI device name, from ATCA-S201 management perspective Access Displays the volumes access privilege settings; default is read/write Total Size The calculated capacity (GB) is the product of ‘Total PE’ x ‘PE Size’. PE Size The physical extent (PE) in LVM is the block-size that physical volumes are using. The default physical extent is 4MB. Total PE This is the summation of physical extents contributed by its members. Allocated Space/PE The number of physical extents committed to logical device definitions. Free Space/PE The number of physical extents not yet committed (available) to new or existing logical devices.
CLI command syntax · Parameter Description

After successfully creating a volume group, the user must next create a logical device which can be assigned to iSCSI or NAS services. The LMV2 configuration menu will update to show the new volume group as shown below.
StorBlade99 ATCA-S201 Available Physical Disks
Group State Capacity File Type Vendor Model Rev Select
/dev/sda ‐none‐ Offline 140205(MBytes) Raw Unknown HITACHI HUC101414CSS300 A410
/dev/sdb ‐none‐ Offline 70136(MBytes) Raw Unknown FUJITSU MAY2073RC 0103
Select 1 or more disks for Volume Group
Volume Access Total Size PE Size Total PEs Allocated Space Free Space Resizable
vga read/write 68(GBytes) 4(MBytes) 17501 0(GBytes) 68(GBytes) resizable
Member PV Name Capacity PE Size Total PE Allocated PE Free PE Status
1 /dev/sdc 68(GBytes) 4(MBytes) 17501 0 17501
Volume LV Name Access Status Open Size Select
Enter size to create or extend GBytes 68
Follow these instructions to create a new logical device
Enter size to create or extend [ ]. (It can exceed the seed value displayed in the box).
Table 29 CLI command syntax, create new logical device Convention: atca_blade set_lvm2 index <diskmask> Y <size> Y +
Ndisk … [Ndisk] variable length mask. Must specify one entry for each available system disk. Size of new logical volume. atca_blade set_lvm2 Y Ndisk Ndisk Y 100 Y + Syntax examples
Create a logical disk of size 100GB.
The user may dynamically expand the space allocated to a logical device.
Follow these instructions to extend an existing volume group
capacity.

Enter size to create or extend [ ]. (It can exceed the seed value displayed in the box).
The user may dynamically delete a logical device, and return all the space to the volume group.
Follow these instructions to extend an existing volume group

By default, all logical devices are unformatted and not yet visible to either iSCSI or NAS services. The manage share menu is used to prepare a logical device for one or more of these services (iSCSI, NFS or SMB). The manage share will display a menu for each logical device defined, along with options to make service assignments.

iSCSI nfs smb Shares Manage Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance
StorBlade99 ATCA-S201 Shared Resource /dev/vga/lva0
Logical Volume Share Name Share Type Block / File Action
/dev/vga/lva0 iSCSI nfs smb
Figure 25 HTML tool, Manage shares menu function
Block File field Description
This button is available for logical devices not yet designated as either iSCSI or NAS. Formatting a physical disk will permanently erase all existing data.
If the Share type field is nfs or smb, this button commits the logical device and enables a “file share mount point”. If the Share type field iSCSI this button is commits the logical device and enables an “iSCSI mount point”. Block Indicates the bytes on the logical device are not managed by the ATCA-S201. If exposed by iSCSI, an external host owns the device in its entirety (partitioning, formatting etc.). File Indicates the logical device is formatted, and the bytes on the device are managed by the ATCA-S201 and its Linux file system including partitioning and formatting.
A newly defined logical drive is immediately ready for iSCSI block sharing. In the example above, the logical disk named /dev/vga/lva0 is ready for “iSCSI share”.

Follow these instructions to assign iSCSI service
Share Name [ ].
Upon completion the ‘Block / File’ field will display Block.
Table 30 CLI command syntax, create iSCSI share Convention: atca_blade manage_shares Y <diskmask> N Y <name> Y Y +
Y |N … [Y|N] variable length mask. Must specify one entry for each system disk. Use to ‘Y’ designate which disk to share. Use ‘N’ in all other positions. < name> Enter human friendly “share name” atca_blade set_shares Y Y N N Y iSCSI_targetAA Y Y + Syntax example
#1 Designate disk 1 of 2, an iSCSI share called iSCSI_target_AA atca_blade set_shares Y N Y N Y iSCSI_targetBB Y Y + Syntax example
#2 Designate disk 2 of 2, an iSCSI share called iSCSI_target_BB
Before a disk may be utilized for file sharing services (nfs/smb), it must be formatted. Depending on the size of the device or virtual volume, formatting may take several minutes.
Follow these instructions to assign NAS service
Share Name [ ].
Formatting can take several minutes, with duration depending on the size.
such as Linux or Solaris®.
Block services, such Microsoft® Windows®.
Upon completion the ‘Block / File’ field will display File.
CLI command syntax

Upon completing these steps, the Mange share menu will update as shown below. Changes may be applied by clicking the appropriate box and clicking ‘Update’.
Table 31 CLI command syntax, format a logical volume Convention: atca_blade set_shares Y <diskmask> Y Y +
Use to ‘Y’ designate which disk to format. Use skip in all other positions. atca_blade set_shares Y skip Y Y Y + Syntax example
#1 Designate disk ‘lva’ an iSCSI share called iSCSI_target_AA atca_blade set_shares Y N Y N Y iSCSI_targetBB Y Y + Syntax example
#2 Designate disk 2 of 2, an iSCSI share called iSCSI_target_BB
The administrator may modify or un-share any currently shared logical device by navigating to the html configuration screen:
Emerson ATCA-S201 Shares Manage Shares The Manage shares menu displays the active status of all logical devices. Scroll to the device of interest, and complete the steps below.

iSCSI nfs smb Shares Manage Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

StorBlade99 ATCA-S201 Shared Resource /dev/vga/lva0
Logical Volume Share Name Share Type Block / File Action
/dev/vga/lva0 lva0 iSCSI nfs smb Block ‐In Use ‐
lva0 /mnt/shr/block/lva0 <-> /mnt/shr/block/lva0 iSCSI nfs smb
Follow these instructions to un-commit a logical drive
Later, the logical device may be reassigned to a new share, or the space returned to the Volume group be deleting the device using the LVM2 configuration menu.
The administrator may modify or un-share any currently shared logical device by navigating to the html configuration screen:
Emerson ATCA-S201 Shares Manage Shares The Manage shares menu displays the active status of all logical devices. Scroll to the device of interest, and complete the steps below.

iSCSI nfs smb Shares Manage Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

StorBlade99 ATCA-S201 Shared Resource /dev/vga/lva0
Logical Volume Share Name Share Type Block / File Action
/dev/vga/lva0 lva0 iSCSI nfs smb Block ‐In Use ‐
lva0 /mnt/shr/block/lva0 <-> /mnt/shr/block/lva0 iSCSI nfs smb
Follow these instructions to un-commit a logical drive
Later, the logical device may be reassigned to a new share, or the space returned to the Volume group be deleting the device using the LVM2 configuration menu.
As a default, the ATCA will name shares based on the underlying device path. Though these is nothing wrong with this, the user may use the ‘manage shares’ menu to assign more appropriate names.
Update

Ethernet Comm. Setup
NFS / SMB Share Setup
This chapter explains how to create one or more iSCSI LUNs for external host access. The user must complete step 4 before this step can be accomplished.
IP host 1:1 mapping (JBOD)
1:1 mapping (JBOD)
Using the HTML configuration tool, navigate to this configuration page .
Emerson ATCA-S201 iSCSI iSCSI Configuration
This top html menu provides the ability to create an iSCSI target on a device (e.g. /dev/vga/lva0) that was previously committed for iSCSI block I/O share (see chapter ).
These are the final steps to make an iSCSI device ‘appear’ on the IP network.


iSCSI iSCSI Configuration nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance
StorBlade99 ATCA-S201 iSCSI Configuration Global Settings
iSNSServer None iSNSAccessControl No
Add an iSCSI Target
Figure 26 HTML tool, Emerson ATCA-S201 iSCSI iSCSI Configuration
Follow these instructions to create a new iSCSI target
After confirming the popup, the iSCSI configuration tool page changes, and will display a list of operating attributes for the new iSCSI target. The menu will also include a new section to create an iSCSI LUN (see next section).
The final step in defining a usable iSCSI resource requires the creation of one or more iSCSI LUNs. A LUN (Logical Unit Number) is an addressable entity on the iSCSI target. A target may have several LUNs, and each LUN maps one-to-one with a logical share device. When an external host subsequently connects to the iSCSI target, it may write to a LUN, which again is mapped to the logical device. An external host may partition and format each LUN individually and write independent data.
Table 32 CLI command syntax, create iSCSI share Convention: atca_blade set_iscsi
This command invokes an interactive session to modify the iSCSI setting of the blade. The command will spawn a series of Yes/No questions which guide the user the iSCSI configuration options. The command session and responses can be scripted to automate a common configuration setup on multiple blades.

Delete This iSCSI Target
Alias NoAlias MaxConnections 1
InitialR2T No ImmediateData Yes
MaxRecvDataSegmentLength 262144 MaxXmitDataSegmentLength 262144
MaxBurstLength 262144 FirstBurstLength 65536
DefaultTime2Wait 2 DefaultTime2Retain 20
MaxOutstandingR2T 8 DataPDUInOrder 1
DataSequenceInOrder 1 ErrorRecoveryLevel 0
HeaderDigest None DataDigest None
Wthreads 8 IET tid 1
0 LUNs Served By This Target
LUN Path Type Remove
Add a new LUN Share to This Target
LUN Path Type Action
ˇ
ˇ
1 LUNs Served By This Target
LUN Path Type Remove
0 /export/iSCSI/lva0 blockio Remove
LUN Path Type Action
blockio No paths available 1
ˇ Fol low these instructions to create an iSCSI LUN
resource.
this LUN.
Add Lun 0 · lva0 · blockio

LUN Path Type Remove
0 /export/iSCSI/lva0 blockio Remove
LUN Path Type Action
blockio No paths available 1
ˇ
Figure 27 SCSI configuration screen updates to show the new LUN.
The user can remove an iSCSI LUN from operation by opening the iSCSI configuration page, and clicking the “remove” box for the LUN, followed by the ‘submit changes’ button at the top of the screen. The data on the LUN is not erased, and remains intact but inaccessible on the target. When complete, the device resource can subsequently be re-assigned as a LUN in another iSCSI target, and data access is restored.
Follow these instructions to delete an iSCSI LUN
The user can remove an iSCSI target (and all LUN assignments) from operation by opening the iSCSI configuration page, and clicking the “Delete This iSCSI Target” button. Clicking this button will generate a pop-up which will ask the user to confirm this operation.
Follow these instructions to delete an iSCSI Target
will remove.

The iSCSI service running on the storage blade supports numerous configuration options that appear in the iSCSI section of web interface tool. Users may modify any number of parameters listed, and then click the ‘submit’ button located at the top of the page.
Alternatively, iSCSI configuration options may be set via simple edits to a text based configuration file /etc/ietd.conf using a console window. The configuration file contains an entry for each target entry created by the web or cli tools. The file contains a stanza style entry for each iSCSI target that begins with the parameter name: “Target”. The file syntax is explained in the next section. File changes become active at next reboot or by re-starting the iSCSI service (as root): /etc/rc.d/init.d/iscsi stop /etc/rc.d/init.d/iscsi start
Sample ietd.conf file for iSCSI targets
Everything before the first Target definition belongs to the global configuration. # iSCSI target configuration file ietd.conf # Target iqn.1995-07.com.emerson:BladeHost.Target0 IncomingUser OutgoingUser NoAlias Alias NoAlias #MaxConnections 1 No InitialR2T No ImmediateData Yes MaxRecvDataSegmentLength 262144 MaxXmitDataSegmentLength 262144 #MaxBurstLength 262144 #FirstBurstLength 65536 #DefaultTime2Wait 2 #DefaultTime2Retain 20 #MaxOutstandingR2T 8 #DataPDUInOrder 1 #DataSequenceInOrder 1
Target Default Settings

#ErrorRecoveryLevel 0 #HeaderDigest None #DataDigest None #Wthreads 8 Lun 0 Path=/export/iSCSI/lva0,Type=blockio,ScsiId=RXEUlYcCN9siiOnP

Table 33 iSCSI Advanced configuration and parameter definitions Target iqn.<yyyy-mm>.<tld.domain.host.Target#>[:<identifier>] Identifies the iSCSI Qualified Name, which is globally unique as required by the iSCSI standard. iqn. followed by a single dot “.” is the date (year and month) at which the domain is valid followed by a single dot “.” Reversed domain name followed by a single dot “.” Host name is assigned on Maintenance->Network page, followed by a dot “.” is set to numerically enumerate each iSCSI target definition. (e.g. Target0, Target1 etc)
The optional - permitted by RFC3720, but is not used IncomingUser <username> <password> Used to set the and to authenticate iSCSI initiators during discovery sessions, using CHAP. Several entries can be specified for each target discovery. If no IncomingUser is specified, any initiator may open a discovery session. Note: RFC 3720 requires to be 12 characters long. This is enforced by Microsoft’s® Initiator. OutgoingUser <username> <password> Used to set the and to authenticate the target to initiators during discovery sessions using CHAP. Only one outgoing / combination may be specified. Note: RFC 3720 requires to be 12 characters long. This is enforced by Microsoft’s® Initiator. Alias <string> May be set to a “friendly” human-readable name or description that is communicated to the initiator at Login. An initiator may elect to display this value when listing connected targets. NOTE: As an additional feature, this string is appended to the target name. MaxConnections Default 1 Sets the maximum number of connections an initiator may make with a each iSCSI target entity. 1 is the only valid value InitialR2T "No" — default: Indicates the initiator may include BurstLength bytes together immediately following an iSCSI command. This setting may reduce protocol handshakes, and thus improve system performance. "Yes" — Indicates the initiator has to wait for the target to solicit SCSI data before sending it. ImmediateData "Yes" — default: Indicates the initiator may combine iSCSI command and data information and send in the same packet. This setting may reduce protocol handshakes, and thus improve system performance. "No" — Indicates the initiator may not combine command and data information in the same packet. MaxRecvDataSegmentLength Default: 262144, sets the maximum data segment length that the target can receive. Note: The should be set to multiples of PAGE_SIZE. The maximum supported value is 64 * 4096 = 262144. MaxXmitDataSegmentLength Default: 262144, sets the maximum data segment length that the target can send. Note: The actual value is reduced to match the MaxXmitDataSegmentLength and the MaxRecvDataSegmentLength negotiated with each initiator during login. The should be set to multiples of PAGE_SIZE. The maximum supported value is 64 * 4096 = 262144. #MaxBurstLength Default: 262144, Sets the maximum amount of data the initiator may send in a single burst.

Note: The should be set to multiples of PAGE_SIZE. The maximum supported value is 16 * 4096 = 65536. #DefaultTime2Wait Not currently supported #DefaultTime2Retain Not currently supported #MaxOutstandingR2T Default: 1, Controls the maximum number of data transfers the target may request at once, each of up to MaxBurstLength bytes. #DataPDUInOrder "Yes" — default:, Indicates the initiator MUST send data PDUs within sequences have to be at continuously increasing addresses. “No” — Not supported. #DataSequenceInOrder "Yes" — default: Indicates the initiator MUST send Data Sequences with continuous non-decreasing sequence offsets (R2T buffer offset for writes, or the smallest SCSI Data-In buffer offset within a read data sequence). “No” — Not supported. #ErrorRecoveryLevel 0 Default 0, Establishes the recovery level supported by the target. #HeaderDigest "None" — default. CRC not enabled. "CRC32C" — Indicates Target will support CRC32C checksum to protect iSCSI PDU’s headers, if requested by initiator.
Notes: (1) data digests are not used during discovery sessions. (2) CRC32C may negatively affect overall target performance. #Wthreads Default: 8 Sets the number of threads used to perform the block I/O to the blades’ disk resources. 8 threads was determined optimal for the majority of deployments and workloads. Lun Path=,Type,ScsiID= defines a mapping between a Logical Unit Number and a block device . : The value between 0 and 2^14-1 : Linux device path mapped to the LUN Indicates the blade will perform direct block i/o with the device, bypassing page-cache for all operations. Optimal for non-aligned sector transfers large block transfers. a unique ID assigned to the iSCSI volume. It is required to assist mulitipath-aware initiator host accessing the same through several targets. The must not exceed 16 characters.

The iSCSI service running on the storage blade includes the ability to limit the targets each host will see during discovery; this can often significantly reduce the iSCSI boot time. The filter mechanism uses the host IP address as criteria to expose or hide iSCSI targets listed in discovery.
The iSCSI discovery filter is configured via simple edits to a pair of text based configuration files: /etc/initiators.allow /etc/initiators.deny
The file syntax is explained in the next section. File changes become active immediately upon save, no reboot is necessary.
Enter the iSCSI iqn followed by one or more ip addresses. Use a comma to separate multiple IP address entries. (Note: Entries must not use tabs) iqn.1995-07.com.emerson:BladeHost.Target0 192.168.1.109 iqn.1995-07.com.emerson:BladeHost.Target1 192.168.1.108, 192.168.1.110
For each iSCSI iqn listed above, make a corresponding entry as shown. Each entry should consist of the iSCSI iqn, followed by the word ALL (Note: Entries must not use tabs). iqn.1995-07.com.emerson:BladeHost.Target0 ALL iqn.1995-07.com.emerson:BladeHost.Target1 ALL


This chapter explains how to establish NFS and SMB mount points for external host access. The configuration menus for the NFS and SMB services are nearly identical, and will be discussed together. The user must complete step 4 before this step can be accomplished.

Using the HTML configuration tool, navigate to either of these configuration pages:


iSCSI nfs nfs Configuration Smb smb Configuration Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

These menus provides the ability to create file mount points for logical devices previously committed for file I/O share (see chapter 6 ).
These are the final steps to make an nfs or smb share ‘appear’ on the IP network.
Follow these instructions to create a new nfs File-Share Export
nfs menu Emerson ATCA-S201 nfs nfs Configuration Use the ‘nfs’ configuration menu to export shares to OS’s using network file services, such as Linux or Solaris®.
StorBlade99 ATCA-S201 Network File Share (nfs) Configuration
Figure 28 HTML tool, Emerson ATCA-S201 nfs nfs Configuration
export.
After confirming the popup, the configuration tool page changes, and will display the newly created export along with several export attributes.
Export Name Client List Access Attributes Action
/export/nfs/lvb0 Remove Update * (rw,sync,no_wdelay,root_squash)
(rw,sync,no_wdelay,root_squash) Syntax note: attributes must be in parenthesis, with no white spaces.

Table 34 CLI command syntax, create nfs share Convention: atca_blade set_nfs This command invokes an interactive session to modify the nfs setting of the blade. The command will spawn a series of Yes/No questions which guide the user the nfs configuration options. The command session and responses can be scripted to automate a common configuration setup on multiple blades.
Follow these instructions to create a new smb File-Share Export
smb menu Emerson ATCA-S201 smb smb Configuration Use the ‘smb’ configuration menu to export shares to OS’s using Server Message Block services, such Microsoft® Windows®.
StorBlade99 ATCA-S201 Network File Share (smb/cifs) Configuration
Security share Guest Access Yes
Workgroup WORKGROUP Netbios Name PPCSAMBA
Log Level 1 Log Size 100
Allowed Hosts ALL Denied Hosts NONE
Share Device Share Name
Figure 29 HTML tool, Emerson ATCA-S201 smb smb Configuration
export.
After confirming the popup, the configuration tool page changes, and will display the newly created export along with several export attributes.
Public Access Guest Access
Open format comment field

Table 35 CLI command syntax, create smb share Convention: atca_blade set_smb This command invokes an interactive session to modify the smb setting of the blade. The command will spawn a series of Yes/No questions which guide the user the smb configuration options. The command session and responses can be scripted to automate a common configuration setup on multiple blades.
The user can remove any export from operation by opening the nfs or smb configuration menu. All data on these exports is NOT lost. It is merely made unavailable and can be exported again at a later time.
Follow these instructions to Delete a file-share export
remove. Confirm the popup message.
CLI command syntax

The file share services running on the storage blade supports numerous configuration features that are not part of the web interface tool, but available via simple edits to a text based configuration file using a console window.
File share service Configuration file
Samba (cifs) /etc/samba/smb.conf
The configuration file contains an entry for each target entry created by the web or cli tools. The file syntax explanations follow in the next section.
Sample smb.conf file for samba/CIFs file shares
Comment lines must start with a ‘#’ or “;” as first character. A line may extend across multiple lines if last character is backslash ‘\’ Parameter names are case insensitive
The configurations applicable to this product are contained in the [global] section. [global] security = share interfaces = 192.168.1.152/255.255.255.0 workgroup = WORKGROUP netbios name = PPCSAMBA hosts deny = NONE hosts allow =ALL
http://us1.samba.org/samba/docs/man/manpages-3/smb.conf.5.html
Sample /etc/export file for nfs file shares
Comment lines must start with a ‘# ’ as first character. A line may extend across multiple lines if last character is backslash ‘\’
The /etc/exports file facilitates the export of file systems to remote hosts, with various user options. Each exported file system should be on its own individual line, with lists of authorized hosts placed after an exported file system, with each entry delimited by spaces. Options for each of the hosts is placed in parentheses directly after the host identifier, without any spaces separating the host and the first parenthesis. -sh-2.05b# cat exports
nfs /etc/exports

Export option syntax:
Table 36 Common nfs export option definitions host1-hostN Host specifies the directory on the storage blade that is the target of the export. Option <wdelay|no_wdelay> no_wdelay- (default) option turns off the delayed writes feature; no_wdelay must be accompanied with the sync option. wdelay- option causes the NFS server to delay writing to the disk if it suspects another write request is imminent. This can improve performance by reducing the number of times the disk must be accessed by separate write commands, reducing write overhead. Option <root_squash> This default setting prevents root users connected remotely from having root privileges and assigns them the user ID for the user nfsnobody. This effectively "squashes" the power of the remote root user to the lowest local user, preventing unauthorized alteration of files on the ATCA storage blade. Option <ro|rw> ro - Mounts of the exported file system are read-only. Remote hosts are not able to make changes to the data shared on the file system. rw- (default) Mounts of the exported file system are read/write. Remote hosts are able to make changes to data shared on the file system Option <sync> The sync setting (default) instructs the Linux kernel to minimize the amount of write data kept in volatile system memory. Though it is sometimes slower to complete all writes to disk, doing so can prevent data loss in the event of a power failure.
/export/nfs/Fileshare nfs_share1(rw,sync,no_wdelay,root_squash) · () ()

This chapter provides information about preserving all existing blade configuration settings and also installing and updating the firmware loaded on the ATCA-S201 storage services blade. At manufacturing time, the ATCA carrier is pre-loaded with firmware prior to shipping. Periodically, new firmware releases are offered to improve the functionality or performance of the ATCA carrier blade.
The following section describes how to create a backup of an existing blade configuration and how to restore this configuration on a replacement blade. The procedure will record the iSCSI, NAS, volume, and share privileges of all disk storage connected to the ATCA-S201. Moreover, it will record IP attributes of all fabric, base and RTM Ethernet ports, as well as any VLAN, bonds or RAID definitions.
The ATCA-S201 blade software keeps all system configuration data in a single archive file. This file contains all customizations made by the user over the life of the blade. Administrators can manually copy this file to a safe location and later reload the configuration if needed.
The following procedure is a detailed description of the web-based export system configuration procedure.
Export System configuration file using web-GUI tool
The action will create a backup file on the host which can be later imported.
iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance
StorBlade99 ATCA-S201 System Maintenance
Export System Configuration /backup/nvdisk.tar.gz

Export system configuration file using CLI
The following procedure is a detailed description of the CLI-based export system configuration procedure.
sftp [email protected]
bin get /backup/nvdisk.tar.gz
The following procedure is a detailed description of the web-based import system configuration procedure.
Import System configuration using web-GUI tool
find the new *.gz firmware file.
Import System configuration using CLI
sftp [email protected]
All firmware code is stored in a single EEPROM flash device located on the carrier blade. The ATCA-S201 flash device is partitioned into regions containing the following code functions:
U-boot Linux Kernel (kernel) Root file system and storage applications (rfs) Non-Volatile blade configuration Data (NVDATA)

Each image contains a CRC signature which is validated by the system prior to loading. The normal methods for updating these code images is to establish a management connection, ( see chapter 3 ) login as administrator, and utilize either the command line interface (CLI) or web-based graphical user interface (GUI) interface outlined later in this chapter . Both of these mechanisms require that the existing firmware is known-good and intact.
Additionally, an alternate emergency recovery method is provided to repair flash contents that are blank, erased or corrupted.
To begin, the user must first download new ATCA firmware component(s). Please contact your Emerson Networks sales person for access.
The download area contains firmware for several products. Locate the latest firmware for the ATCA-S201. Emerson distributes the code as gunu-zip (*.gz) file. The distribution will contain the following three files:
Rootfs.ext.gz.uboot compressed file system firmware image file (version denoted by timestamp) uImage Compressed linux kernel firmware image U-boot.bin Compressed u-boot firmware code image
Two methods exist for upgrading the firmware on the ATCA-S201, one that is web based and one that is command line. Both are equally effective, and both require root administration privileges.
Emerson offers the ability to update the carrier firmware using secure html connections. The user must establish Web access to use this utility. (See chapter 3 New System configuration 3 . The following procedure is a detailed description of the web-based flash update procedure:
File Description

StorBlade99 ATCA-S201 Maintenance Page
File Name Revision Build Date
U‐boot 1.3.0 Apr 27 2009 – 17:44:03
Linux 2.6.23 #28 Wed Jul 1 09:09:29 EDT 2009
Software reset SAS controller
StorBlade99 ATCA-S201 System Maintenance
Export System Configuration /backup/nvdisk.tar.gz
Follow these instructions to load new firmware
must wait, and not navigate away from the open browser window.
upgrade and click the ‘Update’ button.
StorBlade99 ATCA-S201 System Maintenance
/dev/shm/ATCA-S201_V1.0rc7/u-boot
/dev/shm/ATCA-S201_V1.0rc27uImage_2.6.23
/dev/shm/ATCA-S201_V1.0rc27rootfs
Export System Backup /backup/nvdisk.tar.gz

A Pop-up window notifies the user when the flash update completes. The new software becomes active at next reboot. A blade reboot button is available on the ‘ATCA Status’ menu (see
StorBlade99 ATCA-S201 Blade 1 (0x96) Status
Vendor IANA ID Name HW Revision
H8 FW Revision IPMI Rev Model Serial
Emerson 65cd ATCA‐S201 0004 01.10 01.50 ATCA‐S201 100LYMMSSSS
AMC Site B1 (0x7a) Configuration Phy Num Type SAS Address Handle Parent Disk 00 SAS 5000cca000784c49 0009 0001 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B2 (0x7c) Configuration Phy Num Type SAS Address Handle Parent Disk 01 SAS 500000e016cbd032 000a 0002 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B3 (0x7e) Configuration Phy Num Type SAS Address Handle Parent Disk 02 SAS 5000c50005b18665 000b 0003 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B4 (0x80) Configuration Phy Num Type SAS Address Handle Parent Disk 03 SAS 500000e016cbd982 000c 0004 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control
AMC Site B5 (0x8e) Configuration Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson RTM 0106828G 401NYMxxx Enabled True Site Control
Emerson offers a shell script (.sh) to update firmware code stored in flash. This command line script is named sbflash, and is located on the /bin directory of the ATCA-S201.
SYNOPSIS sbflash [-r] [-k] [-u] [-t tftp_serverIP]
sbflash is a shell script which enables the user to selectively update some or all of the firmware components. A blade reboot is required to activate the new firmware components.

OPTIONS -r: indicates the root file system should be replaced with the image on the tftp server.
-k: indicates the linux kernel should be replaced with the image on the tftp server.
-u: indicates the uboot components should be replaced with the image on the tftp server.
-t tftp_serverIP: used to specify the dotted decimal IP address of the remote tftp server. (example -t 192.168.1.151). If this option is omitted, the script will search for tftp at the IP address assigned to U-boot variable assignment for serverip.
Example #1: flash new root file system and kernel from specified tftp server sbflash –r –k –t 192.168.1.151
The following procedure is a detailed description of the CLI flash update procedure:
uboot_flash=/dev/mtd4 rootfs_flash=/dev/mtd2 kernel_flash=/dev/mtd1 Will use TFTP Server 192.168.1.151 Writing root file system image rootfs.ext2.gz.uboot to /dev/mtd2 File rootfs.ext2.gz.uboot not found on local system, try tftp from 192.168.1.151 Successful tftp get of rootfs.ext2.gz.uboot Updating Flash /dev/mtd2 from file rootfs.ext2.gz.uboot ************************************************* Do not interrupt this process * * or the system will be unbootable *
Upgrade firmware procedure

* * ************************************************* Erasing 256 Kibyte @ 31c0000 -- 99 % complete. Programming /dev/mtd2 Verifying rootfs.ext2.gz.uboot Successful update of flash /dev/mtd2 from file rootfs.ext2.gz.uboot /nvdisk/mnt #
The ATCA-S201 hardware actually contains two copies of flash code. The primary image used for normal customer carrier operation, while the second image contains a backup copy preserved for emergency firmware recovery tasks. The contents of the backup flash remain fixed at time of manufacturing and there is no end-user mechanism to modify its contents. This ensures the device is not accidentally re- written or erased. A jumper on the ATCA blade is used to instruct the CPU to boot either the primary flash (normal) or the secondary flash (emergency recovery).
The ATCA-S201 carrier board includes jumpers that are used for special recovery and reset procedures. Jumper locations are shown in Figure 30. Jumpers create an electrical connection between two pins which can be sensed by circuitry on ATCA- S201 to enter special service modes or behavior. Pin 1 is identified with a square solder pad on the printed circuit board. Jumper behavior is described below.
Table 37 JP1, jumper for primary/recovery Flash selection JP1 Jumper Setting
Short Pin 1-2 Normal setting. When in this position, the jumper indicates that boot is loaded from the primary flash device.
Short Pin 2-3 Service setting. When in this position, the jumper indicates that boot code is loaded from the secondary flash device.
Table 38 JP2, jumper for clearing master password JP2 Jumper Setting
Short Pin 1-2 Normal setting. When in this position, the jumper indicates the master password is preserved in flash.
Short Pin 2-3 Service setting. When in this position, the jumper indicates the master password shall be cleared.
Description · Description



DDR2 DIMM

CPU
J33
SAS
J23
J10

Figure 30 ATCA-S201 Jumper locations
The method described in this section explains a procedure to repair primary flash contents that are blank, erased or corrupted. We advise against using this emergency recovery procedure if the ATCA-S201 is functional, and management communications can be conducted.

For security purposes, administrators are encouraged to change factory default passwords to protect unauthorized access and configuration of the storage blades resources. The method described in this section explains a procedure to clear the blades root password to factory default. None of the other user account passwords are cleared.
root password reset procedure (method 1)
This procedure is useful when the user has no access to the RTM serial console port.

root password reset procedure (method 2)
This procedure is useful when the user has access to the serial console port and can operate the U-boot environment. This secondary method allows you to clear the root password without removing the blade from the chassis but does require a power cycle and some familiarity with U-boot.
The above commands will continue the boot sequence and trigger the blades Linux file system to clear the root password. No other passwords are cleared. Do not use saveenv after setting resetroot, otherwise the root password will be reset on every re-boot.

This chapter provides the specifications and connector pin outs for the ATCA-S201 module.
This section provides mechanical, electrical, environmental, and other relevant physical information.
The ATCA-S201 is an 8U (280 mm) height board with 325 mm in depth for standard applications. It complies with IEEE 1101.11 mechanical standards, as required by the PICMG 2.0 Revision 3.0 specification. The ATCA-S201 is keyed to conform to the PICMG 2.10, Keying of ATCA Boards and Backplanes specification.
The ATCA-S201 includes a stacked power supply module with maximum rated output of 210 W of power. This represents a surplus of power vs. the expected power consumption. The power consumption of the RTM is limited to 25 W maximum. The unpopulated base blade (no AMC or RTM) blade will consume 1.04 A at 48 V (50 W).
The environmental specifications for the ATCA-S201 assembly are presented in the table below.

ATCA-S201 Mechanical and Connector Information
Table 39 Environmental specifications for the ATCA-S201 SPECIFICATION VALUE Operating Temperature (airflow 5.0 CFM)
Operating Temperature (airflow 2.0 CFM)
Storage Temperature -40 °C ~ 85 °C Operating Temperature Gradient 11 °C /H (max) Storage Temperature Gradient 20 °C /H (max) Shipping Temperature Gradient 20 °C /H (max) *1 Operating Humidity 8 % ~ 80 % Storage Humidity 5 % ~ 95 % Shipping Humidity 5 % ~ 95 % *1 Wet bulb Maximum Temperature 27 °C Condensation No condensation Atmospheric Pressure and Altitude Operating: 0 ~ 3,000 m Shipping: 0 ~ 12,000 m Operating Shock
See PICMG 3.0 specification, Regulatory guidelines.
Operating Vibration See PICMG 3.0 specification, Regulatory guidelines. RoHS 6 of 6 compliant. Operating voltage -36 to -72 Vdc Operating power 3.12@48V = 150W max total, shared as follows:
Max ATCA blade Current Draw
1.04 @ 48V (50 watts)
Max current draw (each AMC slot) 72 watts (max each) Max current draw (ARTM slot) 25 watts max 100 watts total shared power pool Reliability MTBF: 229481 Hours
NEBS certifications are performed by integrator at a system level (chassis, ATCA, AMC shelf managers etc) The RTM module will not preclude the system from passing NEBS.
The board is designed and implemented so as to minimize electromagnetic emissions, susceptibility, and the effects of electrostatic discharge. The board carries the following certifications:
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 106
(unpopulated)

Table 40 EMC Emission compliancy
ICES-003 2004 Class A Class A Interference-causing Equipment standard (Canada) VCCI V-3/2007.04 Class A Class A ITE emissions requirements (Japan) Europe Commercial: EN5022:2006 Class A, ITE Class A ITE emissions requirements (EU, Europe) AS/NZS CISPR 22:2005 Class A, ITE Class A ITE emissions requirements (Australia) Europe Commercial: EN 55022:1998/A1:2000/A2:2003 Immunity for ITE equipment Europe Commercial: EN 55024:1998A1:2001/A2:2003 Immunity for ITE equipment Europe Commercial: EN 61000-4-2,3,4,5,6 ,11: 2001 EMC Electrostatic discharge immunity
This section provides position and pin-out details of all connectors available on the ATCA-S201.
Description Description

Table 41 Connector Port Identification and Location 1 AMC Slot 0 7 Zone 3, J32 RTM signal connector 2 AMC Slot 1 8 Zone 3, J33 RTM signal connector 3 AMC Slot 2 9 Zone 2, J23 Chassis connector 4 AMC Slot 3 10 Zone 1, J10 Power supply connector 5 SODIMM, DDR2 socket 11 Power supply mezzanine module 6 Zone 3, J30 RTM power connector


Figure 31 ATCA-S201 ATCA Module Connectors
The ATCA-S201 can accept up to four mid-height single width AMC modules. Each slot is routed with PCI Express (AMC.1) and storage (AMC.3) signaling.
Channel 2 of the AMC slots is allocated for SAS signaling. All four AMC are connected to the SAS Controller located on the ATCA carrier. Channel 3 of the AMC slots is allocated for SAS signaling. A manufacturing option is available to provide ONE of the following configurations:
Port 3 is routed to the on board SAS Controller. Port 3 is routed to the Zone 3 RTM connector.

AMC.3 PCI Express
All four slots implement a x4 PCIe connection on channels 4 to 7. All slots are directly connected to the PCI Express switch located on the ATCA carrier.
Table 42 AMC Slot 0, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 0 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0, port 14 15 EXTENDED --
5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --
Table 43 AMC Slot 1, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 1 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0, port 13 15 EXTENDED --
5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --

Table 44 AMC slot 2, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 2 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0 15 EXTENDED -- 5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --
Table 45 AMC slot 3, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 3 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0 15 EXTENDED -- 5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --
The ATCA-S201 includes a standard zone 1 connector designated as J10 on the ATCA board. This connector is implemented with a 30-pin male connector type available from Positronics industries (http://www.connectpositronic.com), part number VPB30W8M400A1.


1 5 9 13
4 8 12 16 17 18 19 20
2 6 10 14
3 7 11 15
21 22 23 24

Figure 32 Zone 1 J10 Connector Port Pin Location Diagram
Table 46 Connector J10, Zone-1 Pin Assignments Pin# Signal Pin# Signal Pin# Signal Pin# Signal 1 NC 10 PP_HA5 19 NC 28 VRTN_A 2 NC 11 PP_HA6 20 NC 29 VRTN_B 3 NC 12 PP_HA7 21 NC 30 N48V_A 4 NC 13 PP_IPMB_SCL_A 22 NC 31 N48V_B 5 PP_HA0 14 PP_IPMB_SDA_A 23 NC 32 PPENABLE_A 6 PP_HA1 15 PP_IPMB_SCL_B 24 NC 33 N48V_A 7 PP_HA2 16 PP_IPMB_SDA_B 25 Shelf Ground 34 N48V_B 8 PP_HA3 17 NC 26 Logic Ground 9 PP_HA4 18 NC 27 PPENABLE_B

The ATCA-S201 provides Ethernet fabric and base ports on the Zone-2 connector designated as J23 on the ATCA board. This connector is implemented with a 4-pin per column type available from Tyco electronics (http://www.tycoelectronics.com), part number 6469081-1.
ATCA Receptacle view


1 2 3 4 5 6 7 8 9 10
Row H G F E D C B A
Figure 33 Zone 2 Connector Port Pin Location Diagram
Table 47 Connector J23, Zone-2 Pin Assignments Row# Interface A B C D E F G H 1 XAUI_0 TX2+ TX2- RX2+ RX2- TX3+ TX3- RX3+ RX3- 2 XAUI_0 TX0+ TX0- RX0+ RX0- TX1+ TX1- RX1+ RX1- 3 XAUI_1 TX2+ TX2- RX2+ RX2- TX3+ TX3- RX3+ RX3- 4 XAUI_1 TX0+ TX0- RX0+ RX0- TX1+ TX1- RX1+ RX1- 5 BASE0 MDIO0+ MDIO0- MDIO1+ MDIO1- MDIO2+ MDIO2- MDIO3+ MDIO3- 6 BASE1 MDIO0+ MDIO0- MDIO1+ MDIO1- MDIO2+ MDIO2- MDIO3+ MDIO3- 7 - 8 - 9 - 10 -

Table 48 Connector J23, Zone-2 Signal Descriptions XAUI_0 Fabric Port 0, 10GbE XAUI TX and Rx signals XAUI_1 Fabric Port 1, 10GbE XAUI TX and Rx signals BASE_0 Base Port 0, 1GbE, MDIO interface signals. For Star or dual star backplanes BASE_1 Base Port 1, 1GbE, MDIO interface signals. For Star or dual star backplanes
The ATCA-S201 routes several I/O signals to the zone 3 connector complex consisting of connectors J30, J32 and J33. These connectors enable future expansion using advanced rear transition modules (RTM) whose ‘J’ connectors mirror the ‘P’ connectors located on the carrier module. All of these connectors utilize a 3-pin per column type available from Tyco electronics (http://www.tycoelectronics.com), part number 6469081-1 .
ATCA Receptacle view


1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10
Row F E D C B A
Figure 34 Zone 3, Connector Port Pin Location Diagram
The ATCA-S201 P32 connector pin assignments and descriptions appear below.
Table 49 Connector P32, Management infrastructure pin assignments Row# Interface A B C D E F

3 SAS-out SAS_TX1+ SAS_TX1- SAS_RX1+ SAS_RX1- UART_TXD0 UART_RXD0 4 SAS-out SAS_TX2+ SAS_TX2- SAS_RX2+ SAS_RX2- NC UART_CTS0# 5 SAS-out SAS_TX3+ SAS_TX3- SAS_RX3+ SAS_RX3- NC NC 6 LAN0 LAN0_MDIO0+ LAN0_MDIO0- LAN0_CTV LAN0_CTV LAN0_MDIO1+ LAN0_MDIO1- 7 LAN0 LAN0_MDIO2+ LAN0_MDIO2- LAN0_LEDACT# LAN0_LEDLNK# LAN0_MDIO3+ LAN0_MDIO3-
9 SAS-in AMC1_TX3+ AMC1_TX3- AMC1_RX3+ AMC1_RX3- AMC3_TX3+ AMC3_TX3- 10 SAS-in AMC2_TX3+ AMC2_TX3- AMC2_RX3+ AMC2_RX3- AMC3_RX3+ AMC3_RX3-
ATCA Receptacle view

Table 50 Connector J32, Management infrastructure signal descriptions SAS-out These signal pairs connect to the SAS controller (LSI-1068) on ATCA-S201, ports 4, 5, 6 and 7. SAS-in These signal pairs route to the Port3 of the AMC slots, sites 0, 1, 2 and 3 LAN0_MDIOxx GbE Management port. 10/100/1000BaseT signals. These signals route to a transceiver owned by the Freescale PowerPC device. LAN0_CTV 10/100/1000BaseT transformer Center Tap signal, which could be used to terminate center tap of transformers, if they are placed on RTM. This signal is applicable if Ethernet PHY is located on ATCA blade, while GE transformers are located on RTM. LEDACT# LAN 0 (Management) activity indicator signal for LED (active low)
LEDLINK# LAN 0 (Management) LINK indicator signal for LED (active low) UART_ RS232 Serial Signals, transmit, receive, clear to send, request to send, data terminal ready, data set ready. These signals route to the Freescale PowerPC device.
The ATCA-S201 J33 connector pin assignments and descriptions appear below.
Table 51 Connector J33, PCIe and Miscellaneous RTM Pin Assignments Row# Interface A B C D E F 1 PCIe PETX0+ PETX0- PERX0+ PERX0- FCLKA+ FCLKA- 2 PCIe PETX1+ PETX1- PERX1+ PERX1- NC NC 3 PCIe PETX2+ PETX2- PERX2+ PERX2- NC NC 4 PCIe PETX3+ PETX3- PERX3+ PERX3- NC NC 5 PCIe PETX4+ PETX4- PERX4+ PERX4- NC NC 6 PCIe PETX5+ PETX5- PERX5+ PERX5- JTAG_TCK JTAG_TMS 7 PCIe PETX6+ PETX6- PERX6+ PERX6- JTAG_TRST# JTAG_TDO 8 PCIe PETX7+ PETX7- PERX7+ PERX7- JTAG_TDI PCIRST# 9 Misc NC RTM# PCICFG# 10 Misc. I2C_RST I2C_SCL I2C_SDA NC PS0# ENABLE#


Table 52 Connector J33, PCIe and Miscellaneous RTM Signal Descriptions PETx… PCI-Express transmit differential pair signals PERx… PCI-Express receive differential pair signals FCLKA Fabric clock, as defined in AMC.0 specification. Intended to be used for PCI-Express 100MHz spread spectrum clock. This signal can be either terminated or passed through the CREFCLK via jumpers on the RTM403. The ATCA blade provides no spread spectrum support. PCIRST# PCI-Express reset signal (input). The ATCA board may drive a Logic low to reset PCI-Express switch and PCI-Express interfaces that are behind it. RTM# RTM# signal is grounded by the ATCA-S201 to indicate a MMC controller is present (see AMC.0 specification.) The ATCA implementation shall include a 10Kohm pull-up resistor to management power on the ATCA. In this way, an ATCA is able to detect non-intelligent vs. intelligent RTMs. PCICFG# PCI-Express bus configuration signal. It shall be grounded on RTMs that use a single x8 PCI- Express bus and pulled up on the ATCA with 10Kohm resistor to management power. On RTMs that expect two x4 PCI-Express busses this pin will float (not be connected). Two x4 PCI Express busses are intended for RTM implementations that desire to avoid PCI-Express switch in order to reduce latency. The ATCA-S201 asserts logic ground to this signal. PS0# Active low RTM present signal.PS0# is tied to logic GND on the ATCA blade. PS0# (Connector J33) and PS1# (Connector J30) shall be connected through a diode on the ATCA-S201, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted. ENABLE# When low indicates to RTM that it is fully inserted and that MMC can start execution. Logic high shall keep MMC in reset state. This signal shall have a pull-up resistor as indicated in AMC.0 specification. JTAG_xxx These pins provide a functional JTAG port on the P33 connector. The JTAG chain is for mfg testing only and the chain is not intended for RTM use. I2C_xxx This bus allows an RTM to place peripherals on the ATCA serial management bus.
The ATCA-S201 supplies 12 V and the 3.3 V stand-by voltages to an advanced rear transition modules (RTM) via the P30 connector. The P30 connector assignments also include the IPMI-L interface, PS1#. If needed, an advanced RTM will convert the main 12V payload power into 1.2V, 1.5V, 2.5V and 3.3V by using DCDC converters.
The ATCA-S201 is specified to the following maximum power ratings:
Mean power: 25 W Peak power: 26 W Standard deviation of power from mean power: 0.25 W
The ATCA-S201 P30 connector is implemented by using Metral® 89096-xxx from FCI (www.fciconnect.com).


Figure 35 ‘J30’ RTM Power Receptacle
The ATCA-S201 J30 connector pin assignments and descriptions appear below.
Table 53 J30, RTM Power Pin Header Assignment
Row# Interface 1 2 a Pwr Logic_GND Shelf_GND b Pwr Logic_GND +3.3V MP c IPMI IPMI_SCL_L IPMI_SDA_L d Pwr +12V PP +12V PP e Pwr PS1# NC
Table 54 Connector J30, RTM Power Pin Signal Descriptions PS1# Active low RTM present signal. PS1# shall be pulled up to 3.3 V management power on the ATCA blade. PS0# (Connector P33) and PS1# (Connector P30) shall be connected through a diode on the ATCA-S201, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted. IPMI_SCL_L IPMI bus clock signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0specification. IPMI_SDA_L IPMI bus data signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0 specification. 12VPP 12 V payload power, enabled after successful E-keying, as outlined in the AMC.0 specification. RTM must meet requirements posted for payload power in AMC specification. 3.3V_MP 3.3V Management Power. RTM must meet requirements posted for management power in AMC.0 specification. Shelf_GND Frame/Chassis Safety Ground
Logic_GND (Logic 0vdc). Logic Ground- Common return for Management Power Payload Power, reference potential for single ended logic signaling, and shielding for differential pair signals in the AMC Connector.
e d · c b a

The ATCA-S201 incorporates a power mezzanine module from Artesyn® Technologies which performs DC-DC conversions to produce the various voltages needed by the ATCA carrier, its AMC slots and the advanced rear transition module is installed. The module supplier is.
Pin# Signal Pin# Signal Pin# Signal Pin# Signal 1 -48_A 9 C_CL 17 A2 25 3V3_OUT 2 -48_B 10 HU 18 INTRPT 26 3V3_OUT 3 NC 11 HUHU+OUT 19 A1 27 NC 4 NC 12 HU+IN 20 SCL 28 NC 5 RTN_A 13 ON/OFF- 21 A0 29 12V_OUT 6 RTN_B 14 ON/OFF+ 22 SDA 30 12V_RTN 7 EN_A 15 B_OK# 23 3V3_RTN 31 8 EN_B 16 A_OK# 24 3V3_RTN 32

The ATCA-S201 incorporates a SODIMM socket which holds the DDR2 memory for the onboard PowerPC® processor.

The RTM-ATCA-SXXX is an Advanced Rear transition module (RTM) that features a SAS expander which provides a storage I/O path between the front ATCA board and rear I/O access panel. The front ATCA board connection conforms to the 3-row Advanced RTM standard. Optionally, the module may be populated with up to two (2) SAS, SATA or SSD 2.5” disk drives. .
Users may pair the RTM-ATCA-SXXX with ATCA disk carriers (ATCA-S120) to create in-chassis JBOD. The RTM-ATCA-SXXX may also be used to add more disk capacity to other ATCA carrier products ATCA cards with proper zone-3 connector pin-outs can extend connectivity to connectors on the RTM panel. All rear panel connectors are compatible with commodity off-the-shelf, non- proprietary cables. Standard connectors include a x4 SAS/SATA IB connector and two RJ45 pass-through management ports (RS232 and 1 GbE Ethernet). The RTM-ATCA-SXXX includes a modular management controller (MMC) and conforms to the PICMG 3.1 revision 2 specification.
The RTM-ATCA-SXXX is a 8U (233.35mm) x 80mm single slot Rear Transition Module with very few active silicon components. The prominent attributes include:
One X4 IB-SAS/SATA port (Infiniband style SFF-8470) Accommodates up to two disks (manufacturing assembly option) 1Gb RS232 LAN port (pass through connection to Front ATCA blade) - LED drive logic RS232 Port ((pass through connection to Front ATCA blade) MMC, with hot swap and LED control, FRUID serial EERPORM (note: The FRU ID is not a separate part but rather embedded in the MMC controller.) Temperature sensors Voltage sensors SPI flash memory
The RTM-ATCA-SXXX is fully compliant with the following PCI Industrial Computer Manufacturers Group (PICMG) specifications:
11.3 I/O Interfaces
The RTM-ATCA-SXXX mates to ATCA carrier blades via zone-3 connectors in a fashion conforming to PICMG 3.0 ATCA specification revision 2. Internally the ATCA- S201 provides connections to “bridge” between zone3 and the RTM faceplate as follows:
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 118

Table 55 I/O Ports Available on RTM Faceplate RTM Zone-3 function RTM Faceplate RS232 Console port Port 1 —RJ45
SAS, x4 (3.0GHz) Port 2 — IB SAS connector (SFF-8470)
1Gb Ethernet Management port Port 3 - RJ45 IPMI — to MMC device on RTM NA Power NA



Figure 36, RTM-ATCA-SXXX Functional Interconnect Diagram
The RTM-ATCA-SXXX provides a x4 SAS port, implemented with a infiniband Style connector. Depending on RTM factory configuration, this will carry 4 SAS lanes.
The RTM-ATCA-SXXX provides can accommodate SAS Cables up to3M in length.
An Ethernet management port is provided on the RTM-ATCA-SXXX to facilitate a pass-through communication path to certain ATCA board products. The port uses an RJ-45 connector, with integrated LED for Link (green) and activity (amber). The port auto negotiates to either 10/100/1000BASE-T.
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 119
10BRTM‐ATCA‐SXXX Overview


Figure 37, Ethernet Management Port
An RS232 serial console port is provided on the RTM-ATCA-SXXX to facilitate a pass- through communication path to certain ATCA board products. The port uses an RJ45 connector.
The following LEDs are located on the face plate of the RTM-ATCA-SXXX.
Table 56 LEDs On RTM Faceplate LED RTM Faceplate On LAN management activity LED Ethernet Activity AMBER
Off No Activity On LAN management LINK LED Ethernet Link GREEN
Off No Link On Management power available to the module and the module can safely be extracted Off The module is operational and is unsafe for extraction Long Blink Delay before module is activated
Hot Swap (HS) BLUE
Short Blink Delay before module is de-activated On Module Fault set by Shelf manager or 12V payload power not detected. Fault or “Out of Service” (OOS) RED
Off No module fault 12V payload power is being supplied to board On 12V payload power is being supplied to board Module Ready (OK) and “in service” GREEN
Off 12V payload power is not detected


Figure 38 RTM-ATCA-SXXX Front Panel LEDs
The RTM-ATCA-SXXX requires no special software to operate. As shipped from the factory, the expander is un-zoned, and configured for table routing.
The information in this manual applies to the following products:

Figure 39. RTM-ATCA-SXXX Top View (Two Disk Drives)
At manufacturing time, several labels are affixed to the RTM-ATCA-SXXX as shown below. For proper identification of the RTM, use these barcode labels to accurately

determine the module identity. The barcode labels provide the following information:
Table 57 RTM-ATCA-SXXX Identification Labels
For Internal Use Only
L =Location of manufacturer (S)
Y = Calendar year of manufacturer (2008 = 8, 2010=A)
MM = Calendar month of manufacturer (March = 03)
SSSS = Sequence number (reset each month) (1234)
This label contains 2 numbers:
Top = Internal Part Number
Bottom = Ordering Part Number
Label Description


Figure 40 RTM-ATCA-SXXX Diagram Showing Identification Label Locations

This chapter contains the procedures for installing and removing the RTM-ATCA-SXXX.
The RTM-ATCA-SXXX can be installed into an ATCA shelf (chassis) with a midplane made for front and rear board installations. The module must be installed in the slot directly behind the host ATCA node board. These back-to-back slots have common pins to enable passing of signals via the Zone-3 connector complex.
Before installing the rear transition module, verify the module’s part number to ensure that the correct rear transition module is being installed into the system. For information on identifying the rear transition module, see Section11.6.
The RTM-ATCA-SXXX is designed to comply with UL60950-1, and is intended to be used with similarly tested ATCA products that have a user’s guide detailing user installation of module accessories.
There are several manufacturing options for the RTM. The diskless version of the RTM requires no power from the front ATCA node board, but may draw up to 200mA from the 3.3 V management power source. Be sure to validate that the host chassis can supply the RTM slot with these maximum current requirements.
Table 58 Max RTM Module Current Requirements
Module Current RTM-ATCA- SXXX-0 (No Disk)
RTM-ATCA-SXXX-2 (Two disk version)
+12 V (spin up < 100 sec)
0.55 A(6.6W) 2.05 A (25 W) (staggered spin-up) +12 V normal operating
+12 V (idle) 0.55 A (6.6 W) 1.55 A (18.6 W) OFF STATE LESS THAN 0.4 W LESS THAN 0.4 W
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 124

Module Current RTM-ATCA- SXXX (No Disk)
RTM-ATCA-SXXX-2 (Two disk version)
+12 V (spin up < 100 sec)
0.55 A(6.6W) 2.05 A (25 W) (staggered spin-up) +12 V normal operating
+12 V (idle) 0.55 A (6.6 W) 1.55 A (18.6 W) OFF STATE LESS THAN 0.4 W LESS THAN 0.4 W
Boards may be damaged if improperly installed or handled. Please read and follow the guidelines in this section to protect your equipment.
Emerson strongly recommends that you use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to electrostatic discharge (ESD). After removing the component from its protective wrapper or from the system, place the component flat on a grounded, static-free surface (and, in the case of a board, component side up). Do not slide the component over any surface.
If an ESD station is not available, you can avoid damage resulting from ESD by wearing an antistatic wrist strap (available at electronics stores) that is attached to an active electrical ground. Note that a system chassis may not be grounded if it is unplugged.
Bent pins or loose components can cause damage to the board, the backplane, or other system components. Carefully inspect your board and the backplane for both pin and component integrity before installation. Our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving our factory. Bent pins caused by improper installation or by boards with damaged connectors could void the warranty for the backplane or boards.
If a system contains one or more crushed pins, power off the system and contact your local sales representative to schedule delivery of a replacement chassis assembly.
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 125
RTM-ATCA-SXXX Installation

When first installing boards in an empty chassis or onto a carrier card, we recommend that you start at the left of the card cage and work to the right. When inserting or removing a board in a slot adjacent to other boards, use extra caution to avoid damage to the pins and components located on the primary or secondary sides of the boards.
To preserve compliance with applicable standards and regulations for electromagnetic interference (EMI), during operation all front and rear openings on the chassis or board faceplates must be filled with an appropriate card or covered with a filler panel. If the EMI barrier is open, devices may cause or be susceptible to excessive interference.
Your RTM is electrically designed for hot swap within a fully powered chassis. To facilitate hot swap, there is a blue LED on the rear faceplate. This LED is under software control.
If your system is using software that provides full hot swap capabilities, the software will illuminate the blue hot swap LED on the rear faceplate when software has stopped and it is safe to remove the advanced rear transition module.
If your system does not have hot swap-aware software running, behavior of the blue LED is indeterminate. In this case, you may need to manually shut down applications or operating systems running on the board prior to board removal, even if the blue LED is lit.
Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.
Prevent possible damage to module components by verifying the proper slot usage for your configuration.
This section describes a recommended procedure for installing the RTM module in a chassis.
Before you install your module, please read all cautions, warnings, and instructions presented in this section.
RTM‐ATCA‐SXXX Installation

Handling modules and peripherals can result in static damage. Use a grounded wrist strap, static-dissipating work surface, and antistatic containers when handling and storing components.
Insert the board by holding the Module Handles–do not exert unnecessary pressure on the faceplate.
Hot swap compliant modules may be installed while the system is powered on. If a module is not hot swap compliant, you should remove power to the slot or system before installing the module.

Figure 41 Injector / Ejector Latch and Locking Screw
RTM‐ATCA‐SXXX Installation

The RTM-ATCA-SXXX is hot-swappable and can be removed from the chassis without powering down its associated node board. This section describes a recommended procedure for removing a board module from a chassis.
Before you remove your module, please read all cautions, warnings, and instructions presented in this section. Hot swap compliant modules may be removed while the system is powered on. If the chassis is not hot swap compliant, you should remove power to the slot or system before removing the module.
To remove a rear transition module, follow these steps:
This section provides information to verify the installation of the RTM-ATCA-SXXX. Visually inspect the module power LED on the RTM panel. Refer to Figure 38 RTM- ATCA-SXXX Front Panel LEDs.
RTM‐ATCA‐SXXX Installation

This chapter provides the specifications and connector pin outs for the RTM-ATCA-SXXX.
This section provides mechanical, electrical, environmental, and other relevant information.
The RTM-ATCA-SXXX is an 8U (233.35 mm) height board with 80 mm in depth for standard applications. It complies with IEEE 1101.11 mechanical standards, as required by the PICMG 2.0 Revision 3.0 specification. The RTM-ATCA-SXXX is keyed to conform to the PICMG 2.10, Keying of ATCA Boards and Backplanes specification.
There are several manufacturing options for the RTM. Be sure to validate the host chassis, can supply the RTM slot with these maximum current requirements.
Table 59 Max RTM Module Current Requirements
Module Current ATCA-S201-0 (No Disk)
ATCA-S201-2 (Two disk version)
+12V (spin up < 100 sec)
0.55A(6.6W) 2.05A (25W) (staggered spin-up) +12v normal operating
+12v (idle) 0.55A (6.6W) 1.55A (18.6W) OFF STATE LESS THAN 0.4W LESS THAN 0.4W
The environmental specifications for the RTM-ATCA-SXXX assembly are presented in the table below.
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 129

RTM-ATCA-SXXX Mechanical and Connector Information
Table 60 Environmental Specifications for the ATCA-S201 SPECIFICATION VALUE Operating Temperature (airflow 3.1 CFM) 0°C ~ 55 °C Storage Temperature -40 °C ~ 85 °C Operating Temperature Gradient 11 °C /H (max) Storage Temperature Gradient 20 °C /H (max) Shipping Temperature Gradient 20 °C /H (max) *1 Operating Humidity 8 % ~ 80 % Storage Humidity 5 % ~ 95 % Shipping Humidity 5 % ~ 95 % *1 Wet bulb Maximum Temperature 27 °C Condensation No condensation Atmospheric Pressure and Altitude Operating: 0 ~ 3,000 m Shipping: 0 ~ 12,000 m Operating Shock
See PICMG 3.0 specification, Regulatory guidelines.
Operating Vibration See PICMG 3.0 specification, Regulatory guidelines. RoHS 6 of 6 compliant.
NEBS certifications are performed by integrator at a system level (chassis, ATCA, AMC shelf managers etc). The RTM module will not preclude the system form passing NEBS.
The board is designed and implemented so as to minimize electromagnetic emissions, susceptibility, and the effects of electrostatic discharge. The board carries the following certifications:
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 130

RTM‐ATCA‐SXXX Mechanical and Connector Information
Table 61 EMC Emission Compliancy Description Description US: FCC 47 CFR Part 15 Class A Yes, Class A emissions requirements (USA) Canada: ICES 003 Class A Yes Class A Digital Apparatus emissions (Canada) Japan: VCCI Class A Yes Class A ITE emissions requirements (Japan) Europe Commercial: EN 55022:1994 Class A Yes, Class A ITE emissions requirements (EU)
Europe Commercial: EN 61000-3-2,3 Yes, Limits for harmonic current emissions Europe Telecom Carrier: EN 300-386 v1.3.3 April 2005
Requirements for Telecom Network Equipment — Non-Telco Centers Europe CE Mark Yes Australia: AS/NZS 3548 C-Tick Yes, Class A ITE emissions requirements (Australia) South Korea: MIC Taiwan: BSMI
This section provides position and pin-out details of all connectors available on the RTM-ATCA-SXXX.

RTM‐ATCA‐SXXX Mechanical and Connector Information
Table 62 Connector Port Identification and Location 1 Serial console port 4 Zone 3 Connector 2 SAS Connector 5 Power connector 3 10/100/1000 Mb management port 6 RTM alignment pin

Figure 42 RTM-ATCA-SXXX Connectors
Port 3 provides an infiniband (IB) SAS connector, SFF-8470. The port is wired as pass-through to the front ATCA carrier via the J32/P32 Zone-3 connector. This receptacle features jack screws to mechanically secure the external cable. A cable can be ordered from Emerson.
Figure 43. RTM-ATCA-SXXX Front Panel SAS Connector Pin-Out Diagram
Top


RTM‐ATCA‐SXXX Mechanical and Connector Information
Table 63. RTM-ATCA-SXXX Front Panel SAS Connector Pin Assignments
Connecto r Pin Description SAS_RX0 + S1 SAS_RX0- S2
SAS Lane 0, Rx Differential Pair, Drives ATCA Zone 3 connector (P32) SAS_RX1 + S3 SAS_RX1- S4
SAS Lane 1, Rx Differential Pair, Drives ATCA Zone 3 connector (P32) SAS_RX2 + S5 SAS_RX2- S6
SAS Lane 2, Rx Differential Pair, Drives ATCA Zone 3 connector (P32) SAS_RX3 + S7 SAS_RX3- S8
SAS Lane 3, Rx Differential Pair, Drives ATCA Zone 3 connector (P32)
SAS Lane 3, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)
SAS Lane 2, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)
SAS Lane 1, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)
SAS Lane 0, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)
SAS_TX0+ S16
13.2.2 10/100/1000 Mb Management Port
The RTM-ATCA-SXXX provides a 1 GbE management port on the faceplate via RJ45 jack (port 3). The port is wired as pass-through to the front ATCA carrier via the J32/P32 Zone-3 connector
Table 64 10/100/1000 Management Port Connector Pin Assignments Pin Signal Name Pin Signal Name 1 LAN0_A+ 5 LAN0_C- 2 LAN0_A- 6 LAN0_B- 3 LAN0_B+ 7 LAN0_D+ 4 LAN0_C+ 8 LAN0_D-
Figure 44 10/100/1000 Mb Management Port Pin Location Diagram
Signal

RTM‐ATCA‐SXXX Mechanical and Connector Information
Port 4 is a low-profile RJ-45 connector jack that provides RS232 signaling. The port is wired as pass-through to the front ATCA carrier via the J32/P32 Zone-3 connector
Table 65 Serial Console Management Port Connector Pin Assignments Pin Signal Name Pin Signal Name 1 RTS 5 GND 2 DTR 6 RXD 3 TXD 7 DSR 4 GND 8 CTS

Figure 45 Serial Console Management Port Pin Location Diagram
The RTM-ATCA-SXXX routes several I/O signals to the Zone-3 connector complex consisting of connectors J30, J32 and J3. These connectors enable expansion using rear transition modules (RTM) whose ‘J’ connectors mirror the ‘P’ connectors located on the carrier module. All of these connectors utilize a 3-pin per column type available from Tyco electronics (http://www.tycoelectronics.com), part number 6469081-1

RTM‐ATCA‐SXXX Mechanical and Connector Information

Figure 46 Zone 3, Connector Port Pin Location Diagram
The RTM-ATCA-SXXX P32 connector pin assignments and descriptions appear below.
Table 66 Connector P32, Management Infrastructure Pin Assignments Row# Interface A B C D E F

3 SAS SAS_TX1+ SAS_TX1- SAS_RX1+ SAS_RX1- UART_TXD0 UART_RXD0 4 SAS SAS_TX2+ SAS_TX2- SAS_RX2+ SAS_RX2- NC UART_CTS0# 5 SAS SAS_TX3+ SAS_TX3- SAS_RX3+ SAS_RX3- NC NC 6 LAN0 LAN0_MDIO0+ LAN0_MDIO0- LAN0_CTV LAN0_CTV LAN0_MDIO1+ LAN0_MDIO1- 7 LAN0 LAN0_MDIO2+ LAN0_MDIO2- LAN0_LEDACT# LAN0_LEDLNK# LAN0_MDIO3+ LAN0_MDIO3-
9 SAS SAS_TX5+ SAS_TX5- SAS_RX5+ SAS_RX5- SAS_TX7+ SAS_TX7- 10 SAS SAS_TX6+ SAS_TX6- SAS_RX6+ SAS_RX6- SAS_RX7+ SAS_RX7-

RTM‐ATCA‐SXXX Mechanical and Connector Information
Table 67 Connector J32, Management Infrastructure Signal Descriptions SAS ports 4-7 A manufacturing option exists for these signals. These pins are either No-connect, or These transceiver pairs will connect port2 of the AMC front slots. (Port 4 routes to site 0) SAS ports 0-3 These transceiver pairs will connect port3 of the AMC front slots (Port 0 routes to site 0) LAN0_MDIOxx GbE Management port. 10/100/1000BaseT signals. These signals route to a transceiver owned by the Freescale PowerPC device. LAN0_CTV 10/100/1000BaseT transformer Center Tap signal, which could be used to terminate center tap of transformers, if they are placed on RTM. This signal is applicable if Ethernet PHY is located on ATCA blade, while GE transformers are located on RTM. LEDACT# LAN 0 (Management) activity indicator signal for LED (active low) LEDLINK# LAN 0 (Management) LINK indicator signal for LED (active low) UART_ RS232 Serial Signals, transmit, receive, clear to send, request to send, data terminal ready, data set ready. These signals route to the Freescale PowerPC device.
The RTM-ATCA-SXXX, J33 connector pin assignments and descriptions appear below.
Table 68 Connector J33, Miscellaneous RTM Pin Assignments Row# Interface A B C D E F 1 NC 2 NC 3 NC 4 NC 5 NC 6 NC 7 NC 8 NC 9 NC 10 Misc. NC PS0# ENABLE#


RTM‐ATCA‐SXXX Mechanical and Connector Information
Table 69 Connector J33, Miscellaneous RTM Signal Descriptions PS0# Active low RTM present signal.PS0# is tied to logic GND on the ATCA blade. PS0# (Connector J33) and PS1# (Connector J30) shall be connected through a diode on the RTM, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted ENABLE# When low indicates to RTM that it is fully inserted and that MMC can start execution. Logic high shall keep MMC in reset state. This signal shall have a pull-up resistor as indicated in AMC.0 specification.
The RTM-ATCA-SXXX supplies 12V and the 3.3V stand-by voltages to an Advanced rear transition modules (RTM) via the P30 connector. The P30 connector assignments also include the IPMI-L interface, PS1#. If needed, an Advanced RTM will convert the main 12V payload power into 1.2V, 1.5V, 2.5V and 3.3V by using DCDC converters.
The RTM-ATCA-SXXX P30 connector is implemented with the Metral® 89096-xxx from FCI (www.fciconnect.com).

Figure 47 ‘J30’ RTM Power Receptacle
The RTM-ATCA-SXXX J30 connector pin assignments and descriptions appear below.
Table 70 J30, RTM Power Pin Header Assignment Row# Interface 1 2 e Pwr PS1# NC d Pwr +12V PP +12V PP c IPMI IPMI_SCL_L IPMI_SDA_L b Pwr Logic_GND +3.3V MP a Pwr Logic_GND Shelf_GND
e d · c b a

RTM‐ATCA‐SXXX Mechanical and Connector Information
Table 71 Connector J30, RTM Power Pin Signal Descriptions PS1# Active low RTM present signal. PS1# shall be pulled up to 3.3V Management Power on the ATCA blade. PS0# (Connector P33) and PS1# (Connector P30) shall be connected through a diode on the RTM, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted IPMI_SCL_L IPMI bus clock signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0specification. IPMI_SDA_L IPMI bus data signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0 specification. 12VPP 12V Payload Power, enabled after successful E-keying, as outlined in the AMC.0 specification. RTM must meet requirements posted for payload power in AMC specification 3.3V_MP 3.3V Management Power. RTM must meet requirements posted for management power in AMC.0 specification. Shelf_GND Frame/Chassis Safety Ground
Logic_GND (Logic 0vdc). Logic Ground- Common return for Management Power Payload Power, reference potential for single ended logic signaling, and shielding for differential pair signals in the AMC Connector.

The ATCA-S201 module supports the intelligent platform management interface (IPMI) version 1.5. This system is used to collect status information from on on-board sensors as well as sensors installed on AMC or RTM modules. Collected information items include:
Hot swap communication with the shelf manager Inlet air temperatures Voltage monitoring Electronic Keying as described in the AMC.0 specification FRU information Drives blue LED indicators for hot swap, OOS (out of service) Drives green LED for module “OK”
The RTM-ATCA-SXXX module includes an MMC device for reporting status information to the ATCA blade. This MMC utilizes an Intelligent Platform Management Interface (IPMI) which will communicate with the ATCA. This MMC controls and monitors the following:
Hot Swap communication with the shelf manager Inlet air temperatures Voltage monitoring Electronic Keying as described in the AMC.0 specification FRU information Drives “blue” LED indicators for Hot Swap. OOS (out of service), Drives “green LED for module “OK”
The design features an IPMI controller consisting of a 16-bit microcontroller, flash and SRAM. The microcontroller uses I2C interface to communicate the shelf management controller (ShMC), sensors, and MMC devices on AMC modules and the RTM if installed.
Support hot-swap operation as defined for AMC modules in PICMG AMC.0 specification “Fail-safe flash update” - if interrupted at anytime, the MMC firmware is still able to respond and re-flash.
The MMC monitors the status of the module and provides this data so it can be read by the shelf manager. Below are the SDRs that the ATCA-S201 and the RTM-ATCA- SXXX modules create.
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 139

Table 72. ATCA-S201 Sensor Data Records

Sensor UNR UC UNC LNC LC LNR ID String
1.0V 1.16 1.13 1.10 0.90 0.87 0.84 +1.0V 1.1V 1.27 1.24 1.21 0.99 0.99 0.91 +1.1V 1.2V 1.40 1.36 1.32 1.08 1.04 1.00 +1.2V 1.5V 1.75 1.70 1.65 1.35 1.30 1.25 +1.5V 1.8V 2.05 2.00 1.95 1.65 1.60 1.55 +1.8V 2.5V 2.90 2.80 2.70 2.30 2.20 2.10 +2.5V 3.3V 3.60 3.55 3.50 3.10 3.00 2.0 +3.3V
AMC exit Temp Zone-3 Exit 80 90 100 N/A N/A N/A Zone3-Exit Inlet Temp 60 70 80 N/A N/A N/A Inlet Temp
AMC Exit Temp 80 90 100 N/A N/A N/A
Table 73. RTM-ATCA-SXXX Sensor Data Records

Sensor UNR UC UNC LNC LC LNR ID String 3.3V 3.60 3.50 3.45 3.15 3.10 3.00 +3.3V 5.0V 5.50 5.35 5.25 4.75 4.65 4.5 +5V 12V 13.60 13.40 13.00 11.00 10.60 10.400 +12V Board Temp (LM75) 70 60 50 N/A N/A N/A Board Temp Inlet Temp (LM60) 70 60 50 N/A N/A N/A Inlet Temp
The ATCA-S201 and the RTM-ATCA-SXXX include the standard FRU data records per the IPMI Platform Management FRU Information Storage Definition, Board Info Area. The ATCA-S201 and the RTM-ATCA-SXXX include additional FRU records as defined in the PICMG 2.9 specification.
Table 74 ATCA-S201 Example FRU Data Records
Board Information ATCA-S201 Version 1 Language Code EN (English) MFG date.time See note *1 Manufacturer Emerson Product Name ATCA-S201 Serial Number 100LYMMssss (See note *2) Part Number 0106826G01A

*1. Manufacturing time is defined as 'minutes since 1/1/96' in the IPMI FRU spec.
AAA = Assembly Number (102)
L =Location of manufacturer
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 14-1

Y = Calendar year of manufacturer (2008 = 8, 2010 = 0)
MM = Calendar month of manufacturer (March = 03)
ssss = Sequence number (reset each month) (1234)
Table 75 RTM-ATCA-SXXX Example FRU Data Records
Board Information RTM-ATCA-SXXX Version 1 Language Code EN (English) MFG date.time See note *1 Manufacturer Emerson Product Name RTM-ATCA-SXXX Serial Number AAALYMMssss (See note *2) Part Number 0106828G01A

*1. Manufacturing time is defined as 'minutes since 1/1/96' in the IPMI FRU spec.
AAA = 401 part code (denotes RTM-ATCA-SXXX)
L =Location of manufacturer (S)
Y = Calendar year of manufacturer (2008 = 8)
MM = Calendar month of manufacturer (March = 03)
SSSS = Sequence number (reset each month) (1234)
Port # Port Name Link type Link type extension

1 unused 2 unused 2 PCIe Lane0 AMC.1 PCI Express type 8 0, Gen1 J33 A1,B1, C1, D1 3 PCIe Lane1 AMC.1 PCI Express type 8 0, Gen1 J33 A2,B2, C2, D2 4 PCIe Lane2 AMC.1 PCI Express type 8 0, Gen1 J33 A3,B3, C3, D3 5 PCIe Lane3 AMC.1 PCI Express type 8 0, Gen1 J33 A4,B4, C4, D4 6 PCIe Lane4 AMC.1 PCI Express type 8 0, Gen1 J33 A5,B5, C5, D5 7 PCIe Lane5 AMC.1 PCI Express type 8 0, Gen1 J33 A6,B6, C6, D6 8 PCIe Lane6 AMC.1 PCI Express type 8 0, Gen1 J33 A7,B7, C7, D7 9 PCIe Lane7 AMC.1 PCI Express type 8 0, Gen1 J33 A8,B8, C8, D8
10 SAS_0 AMC.3 Storage signaling J32-A2, B2, C2, D2
11 SAS_1 AMC.3 Storage signaling J32-A3, B3, C3, D3
IPMI Functions List

12 SAS_2 AMC.3 Storage signaling J32-A4, B4, C4, D4
13 SAS_3 AMC.3 Storage signaling J32-A5, B5, C5, D5
15 AMC1_EO_13 J31 A1,B1, E2, F2
16 AMC1_EO_14 J31 A2,B2, C2, D2
17 AMC1_EO_15 J31 C3,D3, E3, F3
18 AMC1_EO_16 J31 A3,B3, E4, F4
19 AMC1_EO_17 J31 A4, B4, C4, D4
20 AMC1_EO_18 J31 C5, D5, E5, F5
21 AMC1_EO_19 J31 A5, B5, E6, F6
14.3 Supported IPMI Commands
The MMC communicates with the carrier controller through the local IPMB-L bus of the carrier and responds to all mandatory commands for AMC Module Management Controllers (as defined in the RTM Specification), as well as some optional ones.
IPMI Functions List · 22-31 unused

Table 76 Supported IPMI Commands
IPMI/PICMG/A MC Spec NetFn CMD MMC Req IPM Device “Global” Commands Get Device ID 17.1 App 01h Mandatory Broadcast “Get Device ID” 17.9 App 01h Mandatory Messaging Commands Send Message 18.7 App 34h Optional Event Commands Platform Event 23.3 S/E 02h Mandatory Sensor Device Commands Get Device SDR Info 29.2 S/E 20h Mandatory Get Device SDR 29.3 S/E 21h Mandatory Reserve Device SDR Repository 29.4 S/E 22h Mandatory Get Sensor Reading Factors 29.5 S/E 23h Optional Set Sensor Hysteresis 29.6 S/E 24h Optional Get Sensor Hysteresis 29.7 S/E 25h Optional Set Sensor Threshold 29.8 S/E 26h Optional Get Sensor Threshold 29.9 S/E 27h Optional Set Sensor Event Enable 29.10 S/E 28h Optional Get Sensor Event Enable 29.11 S/E 29h Optional Rearm Sensor Events 29.12 S/E 2Ah Optional Get Sensor Event Status 29.13 S/E 2Bh Optional Get Sensor Reading 29.14 S/E 2Dh Mandatory FRU Device Commands Get FRU Inventory Area Info 28.1 Storage 10h Mandatory Read FRU Data 28.2 Storage 11h Mandatory Write FRU Data 28.3 Storage 12h Mandatory ATCA™ Commands Get PICMG Properties 3-9 PICMG 00h Mandatory FRU Control 3-22 PICMG 04h Mandatory
Get FRU LED Properties 3-24 PICMG 05h Mandatory Get LED Color Capabilities 3-25 PICMG 06h Mandatory Set FRU LED State 3-26 PICMG 07h Mandatory Get FRU LED State 3-27 PICMG 08h Mandatory Get Device Locator Record ID 3-29 PICMG 0Dh Mandatory AMC® Commands Set AMC Port State 3-27 PICMG 19h Mandatory Get AMC Port State 3-28 PICMG 1Ah Mandatory
IPMI Functions List · Command

This chapter provides the instruction for upgrading the IPMC (Intelligent Platform Management controller) firmware. If the ATCA-S201 requires new firmware, an upgrade can be performed remotely using a LAN connection to the self manager.
Firmware upgrades are accomplished with ipmitool, a utility for managing IPMI- enabled devices. The utility is an open source derivative which is modified by the shelf management supplier.
The ATCA-S201 keeps a redundant copy of the firmware in the FLASH. Upgrades are reliable and reversible. A failure in the download (error or interruption) does not disturb the IPMC's ability to continue using the "old" firmware or its ability to restart the download process. The IPMC automatically fails back to the previous firmware if there is a problem when first running new code.
The minimum information to complete a firmware upgrade is documented here.
$ ipmitool [-I|-H|-T|-B|-t|-b] hpm upgrade <firmware_file> $ ipmitool [-I|-H|-T|-B|-t|-b] hpm activate
ipmitool lets you manage Intelligent Platform Management Interface (IPMI) functions of either a local or remote system using IPMI V1.5 and IPMI v2.0. Capabilities include printing FRU data, LAN configuration, sensor readings, and remote power control. OPTIONS
Table 77 ipmitool options relevant to firmware upgrades
-I <interface> Selects IPMI interface to use. Supported interfaces that are compiled in are visible in the usage help output. Use lan to designate Ethernet.
-H <address> Remote server address, can be IP address or hostname. This option is required for lan interfaces.
-T <address> If updating AMC, use this to specify optional bus address of the bridge device (ex: Carrier IPMB-0 address if updating an AMC)
-B <bus id> If updating an AMC, these this optional bus ID of the Bridge device (ex: 0 if updating through a IPMC
-t <address> IPMB-L address of the final target
-b <bus id> bus ID of the final target [0=IPMB-0(IPMC), 7=IPMB-L(AMC)]
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 15-1
Option Description

IPMC Firmware Upgrade Procedure
EXAMPLE 1. The following example shows the command sequence for firmware upgrade of an AMC installed on a carrier: $ ipmitool -I lan -H 192.168.0.2 -T 0x82 -B 0 -t 0x74 -b 7 hpm upgrade hpm1fw.img $ ipmitool -I lan -H 192.168.0.2 -T 0x82 -B 0 -t 0x74 -b 7 hpm activate
Line 1 puts the new firmware in the flash device, where hpm1fw.img is the image. Line 2 is used to dynamically load and activate the new firmware.
EXAMPLE 2. The following example shows the command performing firmware upgrade on the carrier itself: $ ipmitool -I lan -H 192.168.0.2 -t 0x82 -b 0 hpm upgrade hpm1fw.img $ ipmitool -I lan -H 192.168.0.2 -t 0x82 -b 0 hpm activate
Line 1 puts the new firmware in the flash device, where hpm1fw.img is the image. Line 2 is used to dynamically load and activate the new firmware.

Bonding 47
create a LUN 81 create a target 80 remove a LUN 83
CIFs support See SMB CLI
blade status 45, 56 Overview 26, 34 scripting options 28 start/invoke 25 syntax examples .35, 36, 39, 40, 43, 45, 56, 59, 64,
Link agregation (802.3ad) See Bonding LVM (Logical Volume Manager)
create a logical device 73 create a logical volume 70 delete a volume 74 extend a volume 73 overview 67
72, 73, 76, 81, 91
DHCP See Ethernet Port Properties
MTU See Ethernet Port Properties
N
Broadast address 44 DHCP 43 Gateway 44 IP address 43 MTU 44 Subnet mask 43
Create an export 89
F
changing 23, 35 recover, reset 103
Updating blade firmware 97
H
overview 57, 63 supported RAID levels 60, 66 RS232
HTML login See Web GUI
default baudrate 21
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 16-3

Create an export 91 Status
vconfig tool 45 view defined VLAN 46
Blade staus menu 54
U
Enable/disable 35
commands 30 environment variables 24, 31 Overview 30
Pages referenced in this manual — manufacturer, support and downloads.