Table of Contents 226 sections 1 ATCA-S201 Overview · 1.1 Features of the ATCA Storage Module · 1.2 I/O PICMG standards compliance · 1.3 Chassis I/O connections · … ShowHide
1 ATCA-S201 Overviewp.171.1 Features of the ATCA Storage Modulep.171.2 I/O PICMG standards compliancep.181.3 Chassis I/O connectionsp.181.3.1 AMC card connectionsp.191.3.2 DDR2 SODIMMp.191.3.3 Zone 1, power backplane connectionsp.191.3.4 Zone 2, backplane connectionsp.191.3.5 Zone 3, Advanced RTM connectorp.191.3.5.1 Ethernet Management portp.201.3.5.2 Serial Console Portp.201.4 LEDsp.211.5 Software driver supportp.221.6 Part Number, Serial Number, and Address Labelsp.222 ATCA-S201 Installationp.242.1 Installation and removal of the ATCA carrier bladep.242.2 Important information about your chassisp.242.3 Safety Statementp.242.3.1 Observe maximum module current requirementsp.242.4 Before you install or Remove the ATCA carrier bladep.252.4.1 Observe ESD Precautionsp.252.4.2 Watch for Bent Pins or Other Damagep.252.5 Use Caution When installing or removing the ATCA carrierp.252.5.1 Preserve EMI Compliancep.252.5.2 Understand Hot Swapp.262.6 Connector Mechanical keyingp.262.7 Verify Slot Usagep.262.8 Installing the ATCA carrier bladep.262.9 Removing the ATCA carrier bladep.282.10 Verifying the Hardware Installationp.282.10.1 To Verify the Hardware Installationp.293 New System configurationp.30RS232 Console portp.313.1.1 System boot overviewp.313.1.2 Flash boot device contentsp.323.1.3 Linux serial console shell windowp.333.2 Default blade login accounts and passwordsp.33Password change procedurep.333.2.2 Password recovery procedurep.333.3 Factory resetp.343.4 Configuring a new ATCA-S201 bladep.343.4.1 Serial portsp.343.4.2 Ethernet portsp.343.4.3 Management Configuration via HTML browserp.35Management configuration via secure shell (SSH)p.353.4.5 Management configuration via serial console shellp.35Command line configuration toolp.363.5.1 Change IP address of any Ethernet resourcep.36Shell, configuration scripting optionsp.383.6 New system configuration, No DHCP serverp.39U-boot console toolp.403.6.1.1 When is U-boot needed?p.40Essential U-boot user commandsp.40U-boot environment variablesp.413.6.4 Manually assign management IP addressesp.423.7 Network boot procedurep.434 Network configurationp.444.1 Enable HTML browser accessp.454.2 HTML Security certificates (https:// )p.454.3 HTML login screenp.454.3.1 Auto logout inactivity periodp.464.3.1.1 Forced user logoutp.464.3.2 Single session management overridep.464.4 HTML home pagep.464.5 Essential System Configuration Stepsp.474.6 System Identification and Time Zone attributesp.484.6.1 Hostnamep.494.6.2 Domain Namep.494.6.3 Datep.494.6.4 Timep.504.6.5 Time Zonep.504.6.6 Name Server listp.514.6.7 NTP Server listp.514.6.8 Network time protocol - NTP (On/Off)p.524.6.9 Ethernet network port identificationp.524.6.10 Enable (online/offline)p.53DHCPp.53IP addressp.53Network (Subnet) maskp.53Broadcastp.54Gatewayp.54MTU sizep.544.6.17 MAC addressp.54VLAN Virtual Local Area Network supportp.55Viewing active VLANp.56Link aggregation and bondingp.574.8.1 Bonding, CLI command syntaxp.584.9 Shelf communicationsp.594.10 I/O Status attributesp.604.11 Blade maintenance, miscellaneous operationsp.614.11.1 Rescan SAS Topology, disk refreshp.624.11.2 Software Reset SAS Controllerp.624.11.3 Reset I/O Status countersp.624.12 CPU Status attributesp.634.13 ATCA Status attributesp.645 RAID Volume Configurationp.67Hardware RAID configurationp.675.1.1 JBOD modep.685.2 Hardware RAID configuration Menu usagep.685.2.1 Hardware RAID levels and capabilitiesp.705.2.2 How new RAID definitions alter device menu displayp.705.2.3 Modify existing RAID configurationsp.71Software RAID configurationp.735.3.1 Software RAID web-configuration menu usagep.735.3.2 Software RAID, CLI command syntaxp.74Software RAID levels and capabilitiesp.766 Prepare Logical Volumes for iSCSI or file sharingp.77Benefits of a logical Volume Group (/dev/vga)p.776.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)p.776.2 Viewing Physical disksp.786.2.1 Interpreting physical disk statusp.786.2.1.1 Disk view refresh, Re-draw Tree buttonp.796.2.1.2 Rescan SAS Topologyp.796.2.1.3 Software Reset SAS Controllerp.796.2.2 View physical disk propertiesp.79Create a logical Volume Group (/dev/vga)p.806.4 Creating a Logical Device (/dev/vga/lva0)p.83Extend/Expand a Logical Device (/dev/vga/lva0)p.83Delete a Logical device (/dev/vga/lva0)p.846.5 Manage shares (prepare logical device for service)p.856.5.1 Commit a logical drive for iSCSI servicep.856.5.2 Commit a logical drive for NAS servicep.866.5.3 Un-commit an iSCSI sharep.876.5.4 Un-commit an NFS/SMB sharep.886.6 Re-name iSCSI shares, make more ‘human-friendly’p.897 iSCSI device setup toolsp.90iSCSI configuration menup.907.1.1 Add or create an iSCSI targetp.90Add or create an iSCSI LUNp.91Remove an individual iSCSI LUNp.937.1.4 Delete an iSCSI Target (and all LUNS)p.937.1.5 Advanced iSCSI configuration (expert mode)p.947.1.6 iSCSI Discovery filter configuration (expert mode)p.988 NFS/SMB Share setup toolsp.99NFS and SMB mount point configuration menusp.998.1.1 Export an nfs or smb sharep.1008.1.2 Remove an individual file-share Exportp.1028.1.3 Advanced file share configuration (expert mode)p.1039 Blade Maintenance and Firmware upgradesp.1059.1 Blade Maintenancep.1059.1.1 Backup your blade configurationp.1059.1.2 Import (restore) a blade configurationp.1069.2 ATCA Firmwarep.1069.2.1 Download New Firmware packagep.1079.2.1.1 Identifying the correct firmware imagep.1079.3 Normal Firmware Update proceduresp.107Web flash tool, update procedure detailsp.1079.3.2 flash_update.sh tool usage and optionsp.1099.3.3 CLI flash tool, update procedure detailsp.1109.4 Emergency firmware recovery, theory of operationp.1119.4.1 Jumper Settingsp.1119.4.2 Emergency flash recovery (factory reset)p.112Clear root passwordp.11310 ATCA-S201 Mechanical and Connector Informationp.11610.1 Specifications for the ATCA-S201p.11510.1.1 Physical dimensionsp.11510.1.2 Power Requirementsp.11510.1.3 Environmental Specifications and Compliancep.11510.1.4 NEBS Compliancep.11610.1.5 Electromagnetic Compliancep.11610.2 Connectors and Pin assignmentsp.11710.2.1 AMC Module Slotsp.11810.2.1.1 AMC Slot B1, Port Assignmentsp.11910.2.1.2 AMC slot B2, Port Assignmentsp.11910.2.1.3 Port Assignments for AMC Slot B3p.12010.2.1.4 AMC Slot B4, Port Assignmentsp.12010.2.2 Zone 1 Connectorsp.12010.2.3 Zone 2 Connectorsp.12110.2.4 Zone 3 Connectorsp.12210.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.12310.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignmentsp.12410.2.4.3 Connector J30, Power Supply for RTMp.12510.2.4.4 Connector J30, RTM Power Pin Assignmentp.12610.2.5 Power Supply Mezzanine Modulep.12710.2.6 SODIMM DDR Modulep.12711 RTM-ATCA-SXXX Overviewp.13311.1 Features of the Advanced Rear Transition Modulep.12811.2 I/O PICMG Standards Compliancep.12811.3 I/O Interfacesp.12811.3.1 External SAS Connectorp.12911.3.1.1 SAS Cable Lengthp.12911.3.2 Ethernet Management Port (RJ-45)p.12911.3.3 Serial Console Port (RJ-45)p.13011.4 LEDsp.13011.5 Software Supportp.13111.6 Products Supported by this Manualp.13111.7 Identification Labelsp.13112 RTM-ATCA-SXXX Installationp.13412.1 Installation and Removal of the Rear Transition Modulep.13412.2 Important Information about Your Chassisp.13412.2.1 Safety Statementp.13412.2.2 Observe Maximum Module Current Requirementsp.13412.3 Before You Install Or Remove The RTMp.13512.3.1 Observe ESD Precautionsp.13512.3.2 Watch for Bent Pins or Other Damagep.13512.4 Use Caution When Installing or Removing RTMp.13612.4.1 Preserve EMI Compliancep.13612.4.2 Understand Hot Swapp.13612.5 Verify Slot Usagep.13612.6 Installing the Advanced Rear Transition Modulep.13612.7 Removing the Advanced Rear Transition Modulep.13812.8 Verifying the Hardware Installationp.13813 RTM-ATCA-SXXX Mechanical and Connector Informationp.13913.1 Specifications for the RTM-ATCA-SXXXp.13913.1.1 Physical Dimensionsp.13913.1.2 Power Requirementsp.13913.1.3 Environmental Specifications and Compliancep.13913.1.4 NEBS Compliancep.14013.1.5 Electromagnetic Compliancep.14013.2 Connectors and Pin Assignmentsp.14113.2.1 SAS Connector Portp.14213.2.2 10/100/1000 Mb Management Portp.14313.2.3 Serial Console Management Portp.14413.2.4 Zone 3 Connectorsp.14413.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.14513.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignmentsp.14613.2.4.3 Connector J30, Power Supply for Advanced RTMp.14713.2.4.4 Connector J30, RTM Power Pin Assignmentp.14714 IPMI Functions Listp.14914.1 IPMI and Management Controller (IPMC)p.14914.2 Sensor data recordsp.14914.2.1 RTM e-Keying Port Assignmentsp.15114.3 Supported IPMI Commandsp.15215 IPMC Firmware Upgrade Procedurep.15415.1 The ipmitool utilityp.15416 Indexp.156
Page 1 of the Emerson ATCA-S201 user manual — 6806800H62B
Page 1 · click to enlarge
Page 1
Emerson ATCA-S201 diagram (page 1)
Fig. 1
Emerson ATCA-S201 diagram (page 1)
Fig. 2

ATCA-S201

Installation and Use

6806800H62B

July 2009

Page 2 of the Emerson ATCA-S201 user manual — USA
Page 2 · click to enlarge
Page 2

2009 Emerson All rights reserved.

Trademarks Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2009 Emerson Electric Co. All other product or service names are the property of their respective owners. Intel® is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. Java™ and all other Java-based marks are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other Countries. Microsoft®, Windows® and Windows Me® are registered trademarks of Microsoft Corporation; and Windows XP™ is a trademark of Microsoft Corporation. PICMG®, CompactPCI®, AdvancedTCA™ and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI Industrial Computer Manufacturers Group. UNIX® is a registered trademark of The Open Group in the United States and other countries.

Notice While reasonable efforts have been made to assure the accuracy of this document, Emerson assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes. Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to a Emerson website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise altered without the permission of Emerson, It is possible that this publication may contain reference to or information about Emerson products (machines and programs), programming, or services that are not available in your country. Such references or information must not be construed to mean that Emerson intends to announce such Emerson products, programming, or services in your country.

Limited and Restricted Rights Legend If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply unless otherwise agreed to in writing by Emerson. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and Documentation clause at DFARS 252.227-7014 (Jun. 1995).

Contact Address Emerson Network Power - Embedded Computing

2900 South Diablo Way, Suite 190 Tempe, AZ 85282

USA

Page 3 of the Emerson ATCA-S201 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

1 ATCA-S201 Overviewp.171.1 Features of the ATCA Storage Modulep.171.2 I/O PICMG standards compliancep.181.3 Chassis I/O connectionsp.181.3.1 AMC card connectionsp.191.3.2 DDR2 SODIMMp.191.3.3 Zone 1, power backplane connectionsp.191.3.4 Zone 2, backplane connectionsp.191.3.5 Zone 3, Advanced RTM connectorp.191.3.5.1 Ethernet Management portp.201.3.5.2 Serial Console Portp.201.4 LEDsp.211.5 Software driver supportp.221.6 Part Number, Serial Number, and Address Labelsp.222 ATCA-S201 Installationp.242.1 Installation and removal of the ATCA carrier bladep.242.2 Important information about your chassisp.242.3 Safety Statementp.242.3.1 Observe maximum module current requirementsp.242.4 Before you install or Remove the ATCA carrier bladep.252.4.1 Observe ESD Precautionsp.252.4.2 Watch for Bent Pins or Other Damagep.252.5 Use Caution When installing or removing the ATCA carrierp.252.5.1 Preserve EMI Compliancep.252.5.2 Understand Hot Swapp.262.6 Connector Mechanical keyingp.262.7 Verify Slot Usagep.262.8 Installing the ATCA carrier bladep.262.9 Removing the ATCA carrier bladep.282.10 Verifying the Hardware Installationp.282.10.1 To Verify the Hardware Installationp.293 New System configurationp.30RS232 Console portp.313.1.1 System boot overviewp.313.1.2 Flash boot device contentsp.323.1.3 Linux serial console shell windowp.333.2 Default blade login accounts and passwordsp.33Password change procedurep.333.2.2 Password recovery procedurep.333.3 Factory resetp.343.4 Configuring a new ATCA-S201 bladep.343.4.1 Serial portsp.343.4.2 Ethernet portsp.343.4.3 Management Configuration via HTML browserp.35Management configuration via secure shell (SSH)p.353.4.5 Management configuration via serial console shellp.35Command line configuration toolp.363.5.1 Change IP address of any Ethernet resourcep.36Shell, configuration scripting optionsp.383.6 New system configuration, No DHCP serverp.39U-boot console toolp.403.6.1.1 When is U-boot needed?p.40Essential U-boot user commandsp.40U-boot environment variablesp.413.6.4 Manually assign management IP addressesp.423.7 Network boot procedurep.434 Network configurationp.444.1 Enable HTML browser accessp.454.2 HTML Security certificates (https:// )p.454.3 HTML login screenp.454.3.1 Auto logout inactivity periodp.464.3.1.1 Forced user logoutp.464.3.2 Single session management overridep.464.4 HTML home pagep.464.5 Essential System Configuration Stepsp.474.6 System Identification and Time Zone attributesp.484.6.1 Hostnamep.494.6.2 Domain Namep.494.6.3 Datep.494.6.4 Timep.504.6.5 Time Zonep.504.6.6 Name Server listp.514.6.7 NTP Server listp.514.6.8 Network time protocol - NTP (On/Off)p.524.6.9 Ethernet network port identificationp.524.6.10 Enable (online/offline)p.53DHCPp.53IP addressp.53Network (Subnet) maskp.53Broadcastp.54Gatewayp.54MTU sizep.544.6.17 MAC addressp.54VLAN Virtual Local Area Network supportp.55Viewing active VLANp.56Link aggregation and bondingp.574.8.1 Bonding, CLI command syntaxp.584.9 Shelf communicationsp.594.10 I/O Status attributesp.604.11 Blade maintenance, miscellaneous operationsp.614.11.1 Rescan SAS Topology, disk refreshp.624.11.2 Software Reset SAS Controllerp.624.11.3 Reset I/O Status countersp.624.12 CPU Status attributesp.634.13 ATCA Status attributesp.645 RAID Volume Configurationp.67Hardware RAID configurationp.675.1.1 JBOD modep.685.2 Hardware RAID configuration Menu usagep.685.2.1 Hardware RAID levels and capabilitiesp.705.2.2 How new RAID definitions alter device menu displayp.705.2.3 Modify existing RAID configurationsp.71Software RAID configurationp.735.3.1 Software RAID web-configuration menu usagep.735.3.2 Software RAID, CLI command syntaxp.74Software RAID levels and capabilitiesp.766 Prepare Logical Volumes for iSCSI or file sharingp.77Benefits of a logical Volume Group (/dev/vga)p.776.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)p.776.2 Viewing Physical disksp.786.2.1 Interpreting physical disk statusp.786.2.1.1 Disk view refresh, Re-draw Tree buttonp.796.2.1.2 Rescan SAS Topologyp.796.2.1.3 Software Reset SAS Controllerp.796.2.2 View physical disk propertiesp.79Create a logical Volume Group (/dev/vga)p.806.4 Creating a Logical Device (/dev/vga/lva0)p.83Extend/Expand a Logical Device (/dev/vga/lva0)p.83Delete a Logical device (/dev/vga/lva0)p.846.5 Manage shares (prepare logical device for service)p.856.5.1 Commit a logical drive for iSCSI servicep.856.5.2 Commit a logical drive for NAS servicep.866.5.3 Un-commit an iSCSI sharep.876.5.4 Un-commit an NFS/SMB sharep.886.6 Re-name iSCSI shares, make more ‘human-friendly’p.897 iSCSI device setup toolsp.90iSCSI configuration menup.907.1.1 Add or create an iSCSI targetp.90Add or create an iSCSI LUNp.91Remove an individual iSCSI LUNp.937.1.4 Delete an iSCSI Target (and all LUNS)p.937.1.5 Advanced iSCSI configuration (expert mode)p.947.1.6 iSCSI Discovery filter configuration (expert mode)p.988 NFS/SMB Share setup toolsp.99NFS and SMB mount point configuration menusp.998.1.1 Export an nfs or smb sharep.1008.1.2 Remove an individual file-share Exportp.1028.1.3 Advanced file share configuration (expert mode)p.1039 Blade Maintenance and Firmware upgradesp.1059.1 Blade Maintenancep.1059.1.1 Backup your blade configurationp.1059.1.2 Import (restore) a blade configurationp.1069.2 ATCA Firmwarep.1069.2.1 Download New Firmware packagep.1079.2.1.1 Identifying the correct firmware imagep.1079.3 Normal Firmware Update proceduresp.107Web flash tool, update procedure detailsp.1079.3.2 flash_update.sh tool usage and optionsp.1099.3.3 CLI flash tool, update procedure detailsp.1109.4 Emergency firmware recovery, theory of operationp.1119.4.1 Jumper Settingsp.1119.4.2 Emergency flash recovery (factory reset)p.112Clear root passwordp.11310 ATCA-S201 Mechanical and Connector Informationp.11610.1 Specifications for the ATCA-S201p.11510.1.1 Physical dimensionsp.11510.1.2 Power Requirementsp.11510.1.3 Environmental Specifications and Compliancep.11510.1.4 NEBS Compliancep.11610.1.5 Electromagnetic Compliancep.11610.2 Connectors and Pin assignmentsp.11710.2.1 AMC Module Slotsp.11810.2.1.1 AMC Slot B1, Port Assignmentsp.11910.2.1.2 AMC slot B2, Port Assignmentsp.11910.2.1.3 Port Assignments for AMC Slot B3p.12010.2.1.4 AMC Slot B4, Port Assignmentsp.12010.2.2 Zone 1 Connectorsp.12010.2.3 Zone 2 Connectorsp.12110.2.4 Zone 3 Connectorsp.12210.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.12310.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignmentsp.12410.2.4.3 Connector J30, Power Supply for RTMp.12510.2.4.4 Connector J30, RTM Power Pin Assignmentp.12610.2.5 Power Supply Mezzanine Modulep.12710.2.6 SODIMM DDR Modulep.12711 RTM-ATCA-SXXX Overviewp.13311.1 Features of the Advanced Rear Transition Modulep.12811.2 I/O PICMG Standards Compliancep.12811.3 I/O Interfacesp.12811.3.1 External SAS Connectorp.12911.3.1.1 SAS Cable Lengthp.12911.3.2 Ethernet Management Port (RJ-45)p.12911.3.3 Serial Console Port (RJ-45)p.13011.4 LEDsp.13011.5 Software Supportp.13111.6 Products Supported by this Manualp.13111.7 Identification Labelsp.13112 RTM-ATCA-SXXX Installationp.13412.1 Installation and Removal of the Rear Transition Modulep.13412.2 Important Information about Your Chassisp.13412.2.1 Safety Statementp.13412.2.2 Observe Maximum Module Current Requirementsp.13412.3 Before You Install Or Remove The RTMp.13512.3.1 Observe ESD Precautionsp.13512.3.2 Watch for Bent Pins or Other Damagep.13512.4 Use Caution When Installing or Removing RTMp.13612.4.1 Preserve EMI Compliancep.13612.4.2 Understand Hot Swapp.13612.5 Verify Slot Usagep.13612.6 Installing the Advanced Rear Transition Modulep.13612.7 Removing the Advanced Rear Transition Modulep.13812.8 Verifying the Hardware Installationp.13813 RTM-ATCA-SXXX Mechanical and Connector Informationp.13913.1 Specifications for the RTM-ATCA-SXXXp.13913.1.1 Physical Dimensionsp.13913.1.2 Power Requirementsp.13913.1.3 Environmental Specifications and Compliancep.13913.1.4 NEBS Compliancep.14013.1.5 Electromagnetic Compliancep.14013.2 Connectors and Pin Assignmentsp.14113.2.1 SAS Connector Portp.14213.2.2 10/100/1000 Mb Management Portp.14313.2.3 Serial Console Management Portp.14413.2.4 Zone 3 Connectorsp.14413.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.14513.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignmentsp.14613.2.4.3 Connector J30, Power Supply for Advanced RTMp.14713.2.4.4 Connector J30, RTM Power Pin Assignmentp.14714 IPMI Functions Listp.14914.1 IPMI and Management Controller (IPMC)p.14914.2 Sensor data recordsp.14914.2.1 RTM e-Keying Port Assignmentsp.15114.3 Supported IPMI Commandsp.15215 IPMC Firmware Upgrade Procedurep.15415.1 The ipmitool utilityp.15416 Indexp.156
Page 4 of the Emerson ATCA-S201 user manual — 4 NETWORK CONFIGURATION .....................................................................................................34
Page 4 · click to enlarge
Page 4

2.10.1 To Verify the Hardware Installation 19

3 NEW SYSTEM CONFIGURATION .................................................................................................20

3.1 RS232 CONSOLE PORT 21 3.1.1 System boot overview 21 3.1.2 Flash boot device contents 22 3.1.3 Linux serial console shell window 23 3.2 DEFAULT BLADE LOGIN ACCOUNTS AND PASSWORDS 23 3.2.1 Password change procedure 23 3.2.2 Password recovery procedure 23 3.3 FACTORY RESET 24 3.4 CONFIGURING A NEW ATCA-S201 BLADE 24 3.4.1 Serial ports 24 3.4.2 Ethernet ports 24 3.4.3 Management Configuration via HTML browser 25 3.4.4 Management configuration via secure shell (SSH) 25 3.4.5 Management configuration via serial console shell 25 3.5 COMMAND LINE CONFIGURATION TOOL 26 3.5.1 Change IP address of any Ethernet resource 26 3.5.2 Shell, configuration scripting options 28 3.6 NEW SYSTEM CONFIGURATION, NO DHCP SERVER 29 3.6.1 U-boot console tool 30 3.6.2 Essential U-boot user commands 30 3.6.3 U-boot environment variables 31 3.6.4 Manually assign management IP addresses 32 3.7 NETWORK BOOT PROCEDURE 33

4 NETWORK CONFIGURATION 34

4.1 ENABLE HTML BROWSER ACCESS 35 4.2 HTML SECURITY CERTIFICATES (HTTPS:// ) 35 4.3 HTML LOGIN SCREEN 35 4.3.1 Auto logout inactivity period 36 4.3.2 Single session management override 36 4.4 HTML HOME PAGE 36 4.5 ESSENTIAL SYSTEM CONFIGURATION STEPS 37 4.6 SYSTEM IDENTIFICATION AND TIME ZONE ATTRIBUTES 38 4.6.1 Hostname 39 4.6.2 Domain Name 39 4.6.3 Date 39 4.6.4 Time 40 4.6.5 Time Zone 40 4.6.6 Name Server list 41 4.6.7 NTP Server list 41 4.6.8 Network time protocol - NTP (On/Off) 42 4.6.9 Ethernet network port identification 42 4.6.10 Enable (online/offline) 43 4.6.11 DHCP 43 4.6.12 IP address 43

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide ii

Page 5 of the Emerson ATCA-S201 user manual — 7 ISCSI DEVICE SETUP TOOLS .......................................................................................................80
Page 5 · click to enlarge
Page 5

4.6.13 Network (Subnet) mask 43 4.6.14 Broadcast 44 4.6.15 Gateway 44 4.6.16 MTU size 44 4.6.17 MAC address 44 4.7 VLAN VIRTUAL LOCAL AREA NETWORK SUPPORT 45 4.7.1 Viewing active VLAN 46 4.8 LINK AGGREGATION AND BONDING 47 4.8.1 Bonding, CLI command syntax 48 4.9 SHELF COMMUNICATIONS 49 4.10 I/O STATUS ATTRIBUTES 50 4.11 BLADE MAINTENANCE, MISCELLANEOUS OPERATIONS 51 4.11.1 Rescan SAS Topology, disk refresh 52 4.11.2 Software Reset SAS Controller 52 4.11.3 Reset I/O Status counters 52 4.12 CPU STATUS ATTRIBUTES 53 4.13 ATCA STATUS ATTRIBUTES 54

5 RAID VOLUME CONFIGURATION 57

5.1 HARDWARE RAID CONFIGURATION 57 5.1.1 JBOD mode 58 5.2 HARDWARE RAID CONFIGURATION MENU USAGE 58 5.2.1 Hardware RAID levels and capabilities 60 5.2.2 How new RAID definitions alter device menu display 60 5.2.3 Modify existing RAID configurations 61 5.3 SOFTWARE RAID CONFIGURATION 63 5.3.1 Software RAID web-configuration menu usage 63 5.3.2 Software RAID, CLI command syntax 64 5.3.3 Software RAID levels and capabilities 66

6 PREPARE LOGICAL VOLUMES FOR ISCSI OR FILE SHARING 67

6.1 BENEFITS OF A LOGICAL VOLUME GROUP (/DEV/VGA) 67 6.1.1 Benefits of a Logical device/disk (/dev/vga/lva0) 67 6.2 VIEWING PHYSICAL DISKS 68 6.2.1 Interpreting physical disk status 68 6.2.2 View physical disk properties 69 6.3 CREATE A LOGICAL VOLUME GROUP (/DEV/VGA) 70 6.4 CREATING A LOGICAL DEVICE (/DEV/VGA/LVA0) 73 6.4.1 Extend/Expand a Logical Device (/dev/vga/lva0) 73 6.4.2 Delete a Logical device (/dev/vga/lva0) 74 6.5 MANAGE SHARES (PREPARE LOGICAL DEVICE FOR SERVICE) 75 6.5.1 Commit a logical drive for iSCSI service 75 6.5.2 Commit a logical drive for NAS service 76 6.5.3 Un-commit an iSCSI share 77 6.5.4 Un-commit an NFS/SMB share 78 6.6 RE-NAME ISCSI SHARES, MAKE MORE ‘HUMAN-FRIENDLY’ 79

7 ISCSI DEVICE SETUP TOOLS 80

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide iii

Page 6 of the Emerson ATCA-S201 user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

1 ATCA-S201 Overviewp.171.1 Features of the ATCA Storage Modulep.171.2 I/O PICMG standards compliancep.181.3 Chassis I/O connectionsp.181.3.1 AMC card connectionsp.191.3.2 DDR2 SODIMMp.191.3.3 Zone 1, power backplane connectionsp.191.3.4 Zone 2, backplane connectionsp.191.3.5 Zone 3, Advanced RTM connectorp.191.3.5.1 Ethernet Management portp.201.3.5.2 Serial Console Portp.201.4 LEDsp.211.5 Software driver supportp.221.6 Part Number, Serial Number, and Address Labelsp.222 ATCA-S201 Installationp.242.1 Installation and removal of the ATCA carrier bladep.242.2 Important information about your chassisp.242.3 Safety Statementp.242.3.1 Observe maximum module current requirementsp.242.4 Before you install or Remove the ATCA carrier bladep.252.4.1 Observe ESD Precautionsp.252.4.2 Watch for Bent Pins or Other Damagep.252.5 Use Caution When installing or removing the ATCA carrierp.252.5.1 Preserve EMI Compliancep.252.5.2 Understand Hot Swapp.262.6 Connector Mechanical keyingp.262.7 Verify Slot Usagep.262.8 Installing the ATCA carrier bladep.262.9 Removing the ATCA carrier bladep.282.10 Verifying the Hardware Installationp.282.10.1 To Verify the Hardware Installationp.293 New System configurationp.30RS232 Console portp.313.1.1 System boot overviewp.313.1.2 Flash boot device contentsp.323.1.3 Linux serial console shell windowp.333.2 Default blade login accounts and passwordsp.33Password change procedurep.333.2.2 Password recovery procedurep.333.3 Factory resetp.343.4 Configuring a new ATCA-S201 bladep.343.4.1 Serial portsp.343.4.2 Ethernet portsp.343.4.3 Management Configuration via HTML browserp.35Management configuration via secure shell (SSH)p.353.4.5 Management configuration via serial console shellp.35Command line configuration toolp.363.5.1 Change IP address of any Ethernet resourcep.36Shell, configuration scripting optionsp.383.6 New system configuration, No DHCP serverp.39U-boot console toolp.403.6.1.1 When is U-boot needed?p.40Essential U-boot user commandsp.40U-boot environment variablesp.413.6.4 Manually assign management IP addressesp.423.7 Network boot procedurep.434 Network configurationp.444.1 Enable HTML browser accessp.454.2 HTML Security certificates (https:// )p.454.3 HTML login screenp.454.3.1 Auto logout inactivity periodp.464.3.1.1 Forced user logoutp.464.3.2 Single session management overridep.464.4 HTML home pagep.464.5 Essential System Configuration Stepsp.474.6 System Identification and Time Zone attributesp.484.6.1 Hostnamep.494.6.2 Domain Namep.494.6.3 Datep.494.6.4 Timep.504.6.5 Time Zonep.504.6.6 Name Server listp.514.6.7 NTP Server listp.514.6.8 Network time protocol - NTP (On/Off)p.524.6.9 Ethernet network port identificationp.524.6.10 Enable (online/offline)p.53DHCPp.53IP addressp.53Network (Subnet) maskp.53Broadcastp.54Gatewayp.54MTU sizep.544.6.17 MAC addressp.54VLAN Virtual Local Area Network supportp.55Viewing active VLANp.56Link aggregation and bondingp.574.8.1 Bonding, CLI command syntaxp.584.9 Shelf communicationsp.594.10 I/O Status attributesp.604.11 Blade maintenance, miscellaneous operationsp.614.11.1 Rescan SAS Topology, disk refreshp.624.11.2 Software Reset SAS Controllerp.624.11.3 Reset I/O Status countersp.624.12 CPU Status attributesp.634.13 ATCA Status attributesp.645 RAID Volume Configurationp.67Hardware RAID configurationp.675.1.1 JBOD modep.685.2 Hardware RAID configuration Menu usagep.685.2.1 Hardware RAID levels and capabilitiesp.705.2.2 How new RAID definitions alter device menu displayp.705.2.3 Modify existing RAID configurationsp.71Software RAID configurationp.735.3.1 Software RAID web-configuration menu usagep.735.3.2 Software RAID, CLI command syntaxp.74Software RAID levels and capabilitiesp.766 Prepare Logical Volumes for iSCSI or file sharingp.77Benefits of a logical Volume Group (/dev/vga)p.776.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)p.776.2 Viewing Physical disksp.786.2.1 Interpreting physical disk statusp.786.2.1.1 Disk view refresh, Re-draw Tree buttonp.796.2.1.2 Rescan SAS Topologyp.796.2.1.3 Software Reset SAS Controllerp.796.2.2 View physical disk propertiesp.79Create a logical Volume Group (/dev/vga)p.806.4 Creating a Logical Device (/dev/vga/lva0)p.83Extend/Expand a Logical Device (/dev/vga/lva0)p.83Delete a Logical device (/dev/vga/lva0)p.846.5 Manage shares (prepare logical device for service)p.856.5.1 Commit a logical drive for iSCSI servicep.856.5.2 Commit a logical drive for NAS servicep.866.5.3 Un-commit an iSCSI sharep.876.5.4 Un-commit an NFS/SMB sharep.886.6 Re-name iSCSI shares, make more ‘human-friendly’p.897 iSCSI device setup toolsp.90iSCSI configuration menup.907.1.1 Add or create an iSCSI targetp.90Add or create an iSCSI LUNp.91Remove an individual iSCSI LUNp.937.1.4 Delete an iSCSI Target (and all LUNS)p.937.1.5 Advanced iSCSI configuration (expert mode)p.947.1.6 iSCSI Discovery filter configuration (expert mode)p.988 NFS/SMB Share setup toolsp.99NFS and SMB mount point configuration menusp.998.1.1 Export an nfs or smb sharep.1008.1.2 Remove an individual file-share Exportp.1028.1.3 Advanced file share configuration (expert mode)p.1039 Blade Maintenance and Firmware upgradesp.1059.1 Blade Maintenancep.1059.1.1 Backup your blade configurationp.1059.1.2 Import (restore) a blade configurationp.1069.2 ATCA Firmwarep.1069.2.1 Download New Firmware packagep.1079.2.1.1 Identifying the correct firmware imagep.1079.3 Normal Firmware Update proceduresp.107Web flash tool, update procedure detailsp.1079.3.2 flash_update.sh tool usage and optionsp.1099.3.3 CLI flash tool, update procedure detailsp.1109.4 Emergency firmware recovery, theory of operationp.1119.4.1 Jumper Settingsp.1119.4.2 Emergency flash recovery (factory reset)p.112Clear root passwordp.11310 ATCA-S201 Mechanical and Connector Informationp.11610.1 Specifications for the ATCA-S201p.11510.1.1 Physical dimensionsp.11510.1.2 Power Requirementsp.11510.1.3 Environmental Specifications and Compliancep.11510.1.4 NEBS Compliancep.11610.1.5 Electromagnetic Compliancep.11610.2 Connectors and Pin assignmentsp.11710.2.1 AMC Module Slotsp.11810.2.1.1 AMC Slot B1, Port Assignmentsp.11910.2.1.2 AMC slot B2, Port Assignmentsp.11910.2.1.3 Port Assignments for AMC Slot B3p.12010.2.1.4 AMC Slot B4, Port Assignmentsp.12010.2.2 Zone 1 Connectorsp.12010.2.3 Zone 2 Connectorsp.12110.2.4 Zone 3 Connectorsp.12210.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.12310.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignmentsp.12410.2.4.3 Connector J30, Power Supply for RTMp.12510.2.4.4 Connector J30, RTM Power Pin Assignmentp.12610.2.5 Power Supply Mezzanine Modulep.12710.2.6 SODIMM DDR Modulep.12711 RTM-ATCA-SXXX Overviewp.13311.1 Features of the Advanced Rear Transition Modulep.12811.2 I/O PICMG Standards Compliancep.12811.3 I/O Interfacesp.12811.3.1 External SAS Connectorp.12911.3.1.1 SAS Cable Lengthp.12911.3.2 Ethernet Management Port (RJ-45)p.12911.3.3 Serial Console Port (RJ-45)p.13011.4 LEDsp.13011.5 Software Supportp.13111.6 Products Supported by this Manualp.13111.7 Identification Labelsp.13112 RTM-ATCA-SXXX Installationp.13412.1 Installation and Removal of the Rear Transition Modulep.13412.2 Important Information about Your Chassisp.13412.2.1 Safety Statementp.13412.2.2 Observe Maximum Module Current Requirementsp.13412.3 Before You Install Or Remove The RTMp.13512.3.1 Observe ESD Precautionsp.13512.3.2 Watch for Bent Pins or Other Damagep.13512.4 Use Caution When Installing or Removing RTMp.13612.4.1 Preserve EMI Compliancep.13612.4.2 Understand Hot Swapp.13612.5 Verify Slot Usagep.13612.6 Installing the Advanced Rear Transition Modulep.13612.7 Removing the Advanced Rear Transition Modulep.13812.8 Verifying the Hardware Installationp.13813 RTM-ATCA-SXXX Mechanical and Connector Informationp.13913.1 Specifications for the RTM-ATCA-SXXXp.13913.1.1 Physical Dimensionsp.13913.1.2 Power Requirementsp.13913.1.3 Environmental Specifications and Compliancep.13913.1.4 NEBS Compliancep.14013.1.5 Electromagnetic Compliancep.14013.2 Connectors and Pin Assignmentsp.14113.2.1 SAS Connector Portp.14213.2.2 10/100/1000 Mb Management Portp.14313.2.3 Serial Console Management Portp.14413.2.4 Zone 3 Connectorsp.14413.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.14513.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignmentsp.14613.2.4.3 Connector J30, Power Supply for Advanced RTMp.14713.2.4.4 Connector J30, RTM Power Pin Assignmentp.14714 IPMI Functions Listp.14914.1 IPMI and Management Controller (IPMC)p.14914.2 Sensor data recordsp.14914.2.1 RTM e-Keying Port Assignmentsp.15114.3 Supported IPMI Commandsp.15215 IPMC Firmware Upgrade Procedurep.15415.1 The ipmitool utilityp.15416 Indexp.156
Page 7 of the Emerson ATCA-S201 user manual — Table of contents
Page 7 · click to enlarge
Page 7

Table of contents

1 ATCA-S201 Overviewp.171.1 Features of the ATCA Storage Modulep.171.2 I/O PICMG standards compliancep.181.3 Chassis I/O connectionsp.181.3.1 AMC card connectionsp.191.3.2 DDR2 SODIMMp.191.3.3 Zone 1, power backplane connectionsp.191.3.4 Zone 2, backplane connectionsp.191.3.5 Zone 3, Advanced RTM connectorp.191.3.5.1 Ethernet Management portp.201.3.5.2 Serial Console Portp.201.4 LEDsp.211.5 Software driver supportp.221.6 Part Number, Serial Number, and Address Labelsp.222 ATCA-S201 Installationp.242.1 Installation and removal of the ATCA carrier bladep.242.2 Important information about your chassisp.242.3 Safety Statementp.242.3.1 Observe maximum module current requirementsp.242.4 Before you install or Remove the ATCA carrier bladep.252.4.1 Observe ESD Precautionsp.252.4.2 Watch for Bent Pins or Other Damagep.252.5 Use Caution When installing or removing the ATCA carrierp.252.5.1 Preserve EMI Compliancep.252.5.2 Understand Hot Swapp.262.6 Connector Mechanical keyingp.262.7 Verify Slot Usagep.262.8 Installing the ATCA carrier bladep.262.9 Removing the ATCA carrier bladep.282.10 Verifying the Hardware Installationp.282.10.1 To Verify the Hardware Installationp.293 New System configurationp.30RS232 Console portp.313.1.1 System boot overviewp.313.1.2 Flash boot device contentsp.323.1.3 Linux serial console shell windowp.333.2 Default blade login accounts and passwordsp.33Password change procedurep.333.2.2 Password recovery procedurep.333.3 Factory resetp.343.4 Configuring a new ATCA-S201 bladep.343.4.1 Serial portsp.343.4.2 Ethernet portsp.343.4.3 Management Configuration via HTML browserp.35Management configuration via secure shell (SSH)p.353.4.5 Management configuration via serial console shellp.35Command line configuration toolp.363.5.1 Change IP address of any Ethernet resourcep.36Shell, configuration scripting optionsp.383.6 New system configuration, No DHCP serverp.39U-boot console toolp.403.6.1.1 When is U-boot needed?p.40Essential U-boot user commandsp.40U-boot environment variablesp.413.6.4 Manually assign management IP addressesp.423.7 Network boot procedurep.434 Network configurationp.444.1 Enable HTML browser accessp.454.2 HTML Security certificates (https:// )p.454.3 HTML login screenp.454.3.1 Auto logout inactivity periodp.464.3.1.1 Forced user logoutp.464.3.2 Single session management overridep.464.4 HTML home pagep.464.5 Essential System Configuration Stepsp.474.6 System Identification and Time Zone attributesp.484.6.1 Hostnamep.494.6.2 Domain Namep.494.6.3 Datep.494.6.4 Timep.504.6.5 Time Zonep.504.6.6 Name Server listp.514.6.7 NTP Server listp.514.6.8 Network time protocol - NTP (On/Off)p.524.6.9 Ethernet network port identificationp.524.6.10 Enable (online/offline)p.53DHCPp.53IP addressp.53Network (Subnet) maskp.53Broadcastp.54Gatewayp.54MTU sizep.544.6.17 MAC addressp.54VLAN Virtual Local Area Network supportp.55Viewing active VLANp.56Link aggregation and bondingp.574.8.1 Bonding, CLI command syntaxp.584.9 Shelf communicationsp.594.10 I/O Status attributesp.604.11 Blade maintenance, miscellaneous operationsp.614.11.1 Rescan SAS Topology, disk refreshp.624.11.2 Software Reset SAS Controllerp.624.11.3 Reset I/O Status countersp.624.12 CPU Status attributesp.634.13 ATCA Status attributesp.645 RAID Volume Configurationp.67Hardware RAID configurationp.675.1.1 JBOD modep.685.2 Hardware RAID configuration Menu usagep.685.2.1 Hardware RAID levels and capabilitiesp.705.2.2 How new RAID definitions alter device menu displayp.705.2.3 Modify existing RAID configurationsp.71Software RAID configurationp.735.3.1 Software RAID web-configuration menu usagep.735.3.2 Software RAID, CLI command syntaxp.74Software RAID levels and capabilitiesp.766 Prepare Logical Volumes for iSCSI or file sharingp.77Benefits of a logical Volume Group (/dev/vga)p.776.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)p.776.2 Viewing Physical disksp.786.2.1 Interpreting physical disk statusp.786.2.1.1 Disk view refresh, Re-draw Tree buttonp.796.2.1.2 Rescan SAS Topologyp.796.2.1.3 Software Reset SAS Controllerp.796.2.2 View physical disk propertiesp.79Create a logical Volume Group (/dev/vga)p.806.4 Creating a Logical Device (/dev/vga/lva0)p.83Extend/Expand a Logical Device (/dev/vga/lva0)p.83Delete a Logical device (/dev/vga/lva0)p.846.5 Manage shares (prepare logical device for service)p.856.5.1 Commit a logical drive for iSCSI servicep.856.5.2 Commit a logical drive for NAS servicep.866.5.3 Un-commit an iSCSI sharep.876.5.4 Un-commit an NFS/SMB sharep.886.6 Re-name iSCSI shares, make more ‘human-friendly’p.897 iSCSI device setup toolsp.90iSCSI configuration menup.907.1.1 Add or create an iSCSI targetp.90Add or create an iSCSI LUNp.91Remove an individual iSCSI LUNp.937.1.4 Delete an iSCSI Target (and all LUNS)p.937.1.5 Advanced iSCSI configuration (expert mode)p.947.1.6 iSCSI Discovery filter configuration (expert mode)p.988 NFS/SMB Share setup toolsp.99NFS and SMB mount point configuration menusp.998.1.1 Export an nfs or smb sharep.1008.1.2 Remove an individual file-share Exportp.1028.1.3 Advanced file share configuration (expert mode)p.1039 Blade Maintenance and Firmware upgradesp.1059.1 Blade Maintenancep.1059.1.1 Backup your blade configurationp.1059.1.2 Import (restore) a blade configurationp.1069.2 ATCA Firmwarep.1069.2.1 Download New Firmware packagep.1079.2.1.1 Identifying the correct firmware imagep.1079.3 Normal Firmware Update proceduresp.107Web flash tool, update procedure detailsp.1079.3.2 flash_update.sh tool usage and optionsp.1099.3.3 CLI flash tool, update procedure detailsp.1109.4 Emergency firmware recovery, theory of operationp.1119.4.1 Jumper Settingsp.1119.4.2 Emergency flash recovery (factory reset)p.112Clear root passwordp.11310 ATCA-S201 Mechanical and Connector Informationp.11610.1 Specifications for the ATCA-S201p.11510.1.1 Physical dimensionsp.11510.1.2 Power Requirementsp.11510.1.3 Environmental Specifications and Compliancep.11510.1.4 NEBS Compliancep.11610.1.5 Electromagnetic Compliancep.11610.2 Connectors and Pin assignmentsp.11710.2.1 AMC Module Slotsp.11810.2.1.1 AMC Slot B1, Port Assignmentsp.11910.2.1.2 AMC slot B2, Port Assignmentsp.11910.2.1.3 Port Assignments for AMC Slot B3p.12010.2.1.4 AMC Slot B4, Port Assignmentsp.12010.2.2 Zone 1 Connectorsp.12010.2.3 Zone 2 Connectorsp.12110.2.4 Zone 3 Connectorsp.12210.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.12310.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignmentsp.12410.2.4.3 Connector J30, Power Supply for RTMp.12510.2.4.4 Connector J30, RTM Power Pin Assignmentp.12610.2.5 Power Supply Mezzanine Modulep.12710.2.6 SODIMM DDR Modulep.12711 RTM-ATCA-SXXX Overviewp.13311.1 Features of the Advanced Rear Transition Modulep.12811.2 I/O PICMG Standards Compliancep.12811.3 I/O Interfacesp.12811.3.1 External SAS Connectorp.12911.3.1.1 SAS Cable Lengthp.12911.3.2 Ethernet Management Port (RJ-45)p.12911.3.3 Serial Console Port (RJ-45)p.13011.4 LEDsp.13011.5 Software Supportp.13111.6 Products Supported by this Manualp.13111.7 Identification Labelsp.13112 RTM-ATCA-SXXX Installationp.13412.1 Installation and Removal of the Rear Transition Modulep.13412.2 Important Information about Your Chassisp.13412.2.1 Safety Statementp.13412.2.2 Observe Maximum Module Current Requirementsp.13412.3 Before You Install Or Remove The RTMp.13512.3.1 Observe ESD Precautionsp.13512.3.2 Watch for Bent Pins or Other Damagep.13512.4 Use Caution When Installing or Removing RTMp.13612.4.1 Preserve EMI Compliancep.13612.4.2 Understand Hot Swapp.13612.5 Verify Slot Usagep.13612.6 Installing the Advanced Rear Transition Modulep.13612.7 Removing the Advanced Rear Transition Modulep.13812.8 Verifying the Hardware Installationp.13813 RTM-ATCA-SXXX Mechanical and Connector Informationp.13913.1 Specifications for the RTM-ATCA-SXXXp.13913.1.1 Physical Dimensionsp.13913.1.2 Power Requirementsp.13913.1.3 Environmental Specifications and Compliancep.13913.1.4 NEBS Compliancep.14013.1.5 Electromagnetic Compliancep.14013.2 Connectors and Pin Assignmentsp.14113.2.1 SAS Connector Portp.14213.2.2 10/100/1000 Mb Management Portp.14313.2.3 Serial Console Management Portp.14413.2.4 Zone 3 Connectorsp.14413.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.14513.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignmentsp.14613.2.4.3 Connector J30, Power Supply for Advanced RTMp.14713.2.4.4 Connector J30, RTM Power Pin Assignmentp.14714 IPMI Functions Listp.14914.1 IPMI and Management Controller (IPMC)p.14914.2 Sensor data recordsp.14914.2.1 RTM e-Keying Port Assignmentsp.15114.3 Supported IPMI Commandsp.15215 IPMC Firmware Upgrade Procedurep.15415.1 The ipmitool utilityp.15416 Indexp.156
Page 8 of the Emerson ATCA-S201 user manual — Table of contents
Page 8 · click to enlarge
Page 8

Table of contents

1 ATCA-S201 Overviewp.171.1 Features of the ATCA Storage Modulep.171.2 I/O PICMG standards compliancep.181.3 Chassis I/O connectionsp.181.3.1 AMC card connectionsp.191.3.2 DDR2 SODIMMp.191.3.3 Zone 1, power backplane connectionsp.191.3.4 Zone 2, backplane connectionsp.191.3.5 Zone 3, Advanced RTM connectorp.191.3.5.1 Ethernet Management portp.201.3.5.2 Serial Console Portp.201.4 LEDsp.211.5 Software driver supportp.221.6 Part Number, Serial Number, and Address Labelsp.222 ATCA-S201 Installationp.242.1 Installation and removal of the ATCA carrier bladep.242.2 Important information about your chassisp.242.3 Safety Statementp.242.3.1 Observe maximum module current requirementsp.242.4 Before you install or Remove the ATCA carrier bladep.252.4.1 Observe ESD Precautionsp.252.4.2 Watch for Bent Pins or Other Damagep.252.5 Use Caution When installing or removing the ATCA carrierp.252.5.1 Preserve EMI Compliancep.252.5.2 Understand Hot Swapp.262.6 Connector Mechanical keyingp.262.7 Verify Slot Usagep.262.8 Installing the ATCA carrier bladep.262.9 Removing the ATCA carrier bladep.282.10 Verifying the Hardware Installationp.282.10.1 To Verify the Hardware Installationp.293 New System configurationp.30RS232 Console portp.313.1.1 System boot overviewp.313.1.2 Flash boot device contentsp.323.1.3 Linux serial console shell windowp.333.2 Default blade login accounts and passwordsp.33Password change procedurep.333.2.2 Password recovery procedurep.333.3 Factory resetp.343.4 Configuring a new ATCA-S201 bladep.343.4.1 Serial portsp.343.4.2 Ethernet portsp.343.4.3 Management Configuration via HTML browserp.35Management configuration via secure shell (SSH)p.353.4.5 Management configuration via serial console shellp.35Command line configuration toolp.363.5.1 Change IP address of any Ethernet resourcep.36Shell, configuration scripting optionsp.383.6 New system configuration, No DHCP serverp.39U-boot console toolp.403.6.1.1 When is U-boot needed?p.40Essential U-boot user commandsp.40U-boot environment variablesp.413.6.4 Manually assign management IP addressesp.423.7 Network boot procedurep.434 Network configurationp.444.1 Enable HTML browser accessp.454.2 HTML Security certificates (https:// )p.454.3 HTML login screenp.454.3.1 Auto logout inactivity periodp.464.3.1.1 Forced user logoutp.464.3.2 Single session management overridep.464.4 HTML home pagep.464.5 Essential System Configuration Stepsp.474.6 System Identification and Time Zone attributesp.484.6.1 Hostnamep.494.6.2 Domain Namep.494.6.3 Datep.494.6.4 Timep.504.6.5 Time Zonep.504.6.6 Name Server listp.514.6.7 NTP Server listp.514.6.8 Network time protocol - NTP (On/Off)p.524.6.9 Ethernet network port identificationp.524.6.10 Enable (online/offline)p.53DHCPp.53IP addressp.53Network (Subnet) maskp.53Broadcastp.54Gatewayp.54MTU sizep.544.6.17 MAC addressp.54VLAN Virtual Local Area Network supportp.55Viewing active VLANp.56Link aggregation and bondingp.574.8.1 Bonding, CLI command syntaxp.584.9 Shelf communicationsp.594.10 I/O Status attributesp.604.11 Blade maintenance, miscellaneous operationsp.614.11.1 Rescan SAS Topology, disk refreshp.624.11.2 Software Reset SAS Controllerp.624.11.3 Reset I/O Status countersp.624.12 CPU Status attributesp.634.13 ATCA Status attributesp.645 RAID Volume Configurationp.67Hardware RAID configurationp.675.1.1 JBOD modep.685.2 Hardware RAID configuration Menu usagep.685.2.1 Hardware RAID levels and capabilitiesp.705.2.2 How new RAID definitions alter device menu displayp.705.2.3 Modify existing RAID configurationsp.71Software RAID configurationp.735.3.1 Software RAID web-configuration menu usagep.735.3.2 Software RAID, CLI command syntaxp.74Software RAID levels and capabilitiesp.766 Prepare Logical Volumes for iSCSI or file sharingp.77Benefits of a logical Volume Group (/dev/vga)p.776.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)p.776.2 Viewing Physical disksp.786.2.1 Interpreting physical disk statusp.786.2.1.1 Disk view refresh, Re-draw Tree buttonp.796.2.1.2 Rescan SAS Topologyp.796.2.1.3 Software Reset SAS Controllerp.796.2.2 View physical disk propertiesp.79Create a logical Volume Group (/dev/vga)p.806.4 Creating a Logical Device (/dev/vga/lva0)p.83Extend/Expand a Logical Device (/dev/vga/lva0)p.83Delete a Logical device (/dev/vga/lva0)p.846.5 Manage shares (prepare logical device for service)p.856.5.1 Commit a logical drive for iSCSI servicep.856.5.2 Commit a logical drive for NAS servicep.866.5.3 Un-commit an iSCSI sharep.876.5.4 Un-commit an NFS/SMB sharep.886.6 Re-name iSCSI shares, make more ‘human-friendly’p.897 iSCSI device setup toolsp.90iSCSI configuration menup.907.1.1 Add or create an iSCSI targetp.90Add or create an iSCSI LUNp.91Remove an individual iSCSI LUNp.937.1.4 Delete an iSCSI Target (and all LUNS)p.937.1.5 Advanced iSCSI configuration (expert mode)p.947.1.6 iSCSI Discovery filter configuration (expert mode)p.988 NFS/SMB Share setup toolsp.99NFS and SMB mount point configuration menusp.998.1.1 Export an nfs or smb sharep.1008.1.2 Remove an individual file-share Exportp.1028.1.3 Advanced file share configuration (expert mode)p.1039 Blade Maintenance and Firmware upgradesp.1059.1 Blade Maintenancep.1059.1.1 Backup your blade configurationp.1059.1.2 Import (restore) a blade configurationp.1069.2 ATCA Firmwarep.1069.2.1 Download New Firmware packagep.1079.2.1.1 Identifying the correct firmware imagep.1079.3 Normal Firmware Update proceduresp.107Web flash tool, update procedure detailsp.1079.3.2 flash_update.sh tool usage and optionsp.1099.3.3 CLI flash tool, update procedure detailsp.1109.4 Emergency firmware recovery, theory of operationp.1119.4.1 Jumper Settingsp.1119.4.2 Emergency flash recovery (factory reset)p.112Clear root passwordp.11310 ATCA-S201 Mechanical and Connector Informationp.11610.1 Specifications for the ATCA-S201p.11510.1.1 Physical dimensionsp.11510.1.2 Power Requirementsp.11510.1.3 Environmental Specifications and Compliancep.11510.1.4 NEBS Compliancep.11610.1.5 Electromagnetic Compliancep.11610.2 Connectors and Pin assignmentsp.11710.2.1 AMC Module Slotsp.11810.2.1.1 AMC Slot B1, Port Assignmentsp.11910.2.1.2 AMC slot B2, Port Assignmentsp.11910.2.1.3 Port Assignments for AMC Slot B3p.12010.2.1.4 AMC Slot B4, Port Assignmentsp.12010.2.2 Zone 1 Connectorsp.12010.2.3 Zone 2 Connectorsp.12110.2.4 Zone 3 Connectorsp.12210.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.12310.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignmentsp.12410.2.4.3 Connector J30, Power Supply for RTMp.12510.2.4.4 Connector J30, RTM Power Pin Assignmentp.12610.2.5 Power Supply Mezzanine Modulep.12710.2.6 SODIMM DDR Modulep.12711 RTM-ATCA-SXXX Overviewp.13311.1 Features of the Advanced Rear Transition Modulep.12811.2 I/O PICMG Standards Compliancep.12811.3 I/O Interfacesp.12811.3.1 External SAS Connectorp.12911.3.1.1 SAS Cable Lengthp.12911.3.2 Ethernet Management Port (RJ-45)p.12911.3.3 Serial Console Port (RJ-45)p.13011.4 LEDsp.13011.5 Software Supportp.13111.6 Products Supported by this Manualp.13111.7 Identification Labelsp.13112 RTM-ATCA-SXXX Installationp.13412.1 Installation and Removal of the Rear Transition Modulep.13412.2 Important Information about Your Chassisp.13412.2.1 Safety Statementp.13412.2.2 Observe Maximum Module Current Requirementsp.13412.3 Before You Install Or Remove The RTMp.13512.3.1 Observe ESD Precautionsp.13512.3.2 Watch for Bent Pins or Other Damagep.13512.4 Use Caution When Installing or Removing RTMp.13612.4.1 Preserve EMI Compliancep.13612.4.2 Understand Hot Swapp.13612.5 Verify Slot Usagep.13612.6 Installing the Advanced Rear Transition Modulep.13612.7 Removing the Advanced Rear Transition Modulep.13812.8 Verifying the Hardware Installationp.13813 RTM-ATCA-SXXX Mechanical and Connector Informationp.13913.1 Specifications for the RTM-ATCA-SXXXp.13913.1.1 Physical Dimensionsp.13913.1.2 Power Requirementsp.13913.1.3 Environmental Specifications and Compliancep.13913.1.4 NEBS Compliancep.14013.1.5 Electromagnetic Compliancep.14013.2 Connectors and Pin Assignmentsp.14113.2.1 SAS Connector Portp.14213.2.2 10/100/1000 Mb Management Portp.14313.2.3 Serial Console Management Portp.14413.2.4 Zone 3 Connectorsp.14413.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.14513.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignmentsp.14613.2.4.3 Connector J30, Power Supply for Advanced RTMp.14713.2.4.4 Connector J30, RTM Power Pin Assignmentp.14714 IPMI Functions Listp.14914.1 IPMI and Management Controller (IPMC)p.14914.2 Sensor data recordsp.14914.2.1 RTM e-Keying Port Assignmentsp.15114.3 Supported IPMI Commandsp.15215 IPMC Firmware Upgrade Procedurep.15415.1 The ipmitool utilityp.15416 Indexp.156
Page 9 of the Emerson ATCA-S201 user manual — Table of contents
Page 9 · click to enlarge
Page 9

Table of contents

1 ATCA-S201 Overviewp.171.1 Features of the ATCA Storage Modulep.171.2 I/O PICMG standards compliancep.181.3 Chassis I/O connectionsp.181.3.1 AMC card connectionsp.191.3.2 DDR2 SODIMMp.191.3.3 Zone 1, power backplane connectionsp.191.3.4 Zone 2, backplane connectionsp.191.3.5 Zone 3, Advanced RTM connectorp.191.3.5.1 Ethernet Management portp.201.3.5.2 Serial Console Portp.201.4 LEDsp.211.5 Software driver supportp.221.6 Part Number, Serial Number, and Address Labelsp.222 ATCA-S201 Installationp.242.1 Installation and removal of the ATCA carrier bladep.242.2 Important information about your chassisp.242.3 Safety Statementp.242.3.1 Observe maximum module current requirementsp.242.4 Before you install or Remove the ATCA carrier bladep.252.4.1 Observe ESD Precautionsp.252.4.2 Watch for Bent Pins or Other Damagep.252.5 Use Caution When installing or removing the ATCA carrierp.252.5.1 Preserve EMI Compliancep.252.5.2 Understand Hot Swapp.262.6 Connector Mechanical keyingp.262.7 Verify Slot Usagep.262.8 Installing the ATCA carrier bladep.262.9 Removing the ATCA carrier bladep.282.10 Verifying the Hardware Installationp.282.10.1 To Verify the Hardware Installationp.293 New System configurationp.30RS232 Console portp.313.1.1 System boot overviewp.313.1.2 Flash boot device contentsp.323.1.3 Linux serial console shell windowp.333.2 Default blade login accounts and passwordsp.33Password change procedurep.333.2.2 Password recovery procedurep.333.3 Factory resetp.343.4 Configuring a new ATCA-S201 bladep.343.4.1 Serial portsp.343.4.2 Ethernet portsp.343.4.3 Management Configuration via HTML browserp.35Management configuration via secure shell (SSH)p.353.4.5 Management configuration via serial console shellp.35Command line configuration toolp.363.5.1 Change IP address of any Ethernet resourcep.36Shell, configuration scripting optionsp.383.6 New system configuration, No DHCP serverp.39U-boot console toolp.403.6.1.1 When is U-boot needed?p.40Essential U-boot user commandsp.40U-boot environment variablesp.413.6.4 Manually assign management IP addressesp.423.7 Network boot procedurep.434 Network configurationp.444.1 Enable HTML browser accessp.454.2 HTML Security certificates (https:// )p.454.3 HTML login screenp.454.3.1 Auto logout inactivity periodp.464.3.1.1 Forced user logoutp.464.3.2 Single session management overridep.464.4 HTML home pagep.464.5 Essential System Configuration Stepsp.474.6 System Identification and Time Zone attributesp.484.6.1 Hostnamep.494.6.2 Domain Namep.494.6.3 Datep.494.6.4 Timep.504.6.5 Time Zonep.504.6.6 Name Server listp.514.6.7 NTP Server listp.514.6.8 Network time protocol - NTP (On/Off)p.524.6.9 Ethernet network port identificationp.524.6.10 Enable (online/offline)p.53DHCPp.53IP addressp.53Network (Subnet) maskp.53Broadcastp.54Gatewayp.54MTU sizep.544.6.17 MAC addressp.54VLAN Virtual Local Area Network supportp.55Viewing active VLANp.56Link aggregation and bondingp.574.8.1 Bonding, CLI command syntaxp.584.9 Shelf communicationsp.594.10 I/O Status attributesp.604.11 Blade maintenance, miscellaneous operationsp.614.11.1 Rescan SAS Topology, disk refreshp.624.11.2 Software Reset SAS Controllerp.624.11.3 Reset I/O Status countersp.624.12 CPU Status attributesp.634.13 ATCA Status attributesp.645 RAID Volume Configurationp.67Hardware RAID configurationp.675.1.1 JBOD modep.685.2 Hardware RAID configuration Menu usagep.685.2.1 Hardware RAID levels and capabilitiesp.705.2.2 How new RAID definitions alter device menu displayp.705.2.3 Modify existing RAID configurationsp.71Software RAID configurationp.735.3.1 Software RAID web-configuration menu usagep.735.3.2 Software RAID, CLI command syntaxp.74Software RAID levels and capabilitiesp.766 Prepare Logical Volumes for iSCSI or file sharingp.77Benefits of a logical Volume Group (/dev/vga)p.776.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)p.776.2 Viewing Physical disksp.786.2.1 Interpreting physical disk statusp.786.2.1.1 Disk view refresh, Re-draw Tree buttonp.796.2.1.2 Rescan SAS Topologyp.796.2.1.3 Software Reset SAS Controllerp.796.2.2 View physical disk propertiesp.79Create a logical Volume Group (/dev/vga)p.806.4 Creating a Logical Device (/dev/vga/lva0)p.83Extend/Expand a Logical Device (/dev/vga/lva0)p.83Delete a Logical device (/dev/vga/lva0)p.846.5 Manage shares (prepare logical device for service)p.856.5.1 Commit a logical drive for iSCSI servicep.856.5.2 Commit a logical drive for NAS servicep.866.5.3 Un-commit an iSCSI sharep.876.5.4 Un-commit an NFS/SMB sharep.886.6 Re-name iSCSI shares, make more ‘human-friendly’p.897 iSCSI device setup toolsp.90iSCSI configuration menup.907.1.1 Add or create an iSCSI targetp.90Add or create an iSCSI LUNp.91Remove an individual iSCSI LUNp.937.1.4 Delete an iSCSI Target (and all LUNS)p.937.1.5 Advanced iSCSI configuration (expert mode)p.947.1.6 iSCSI Discovery filter configuration (expert mode)p.988 NFS/SMB Share setup toolsp.99NFS and SMB mount point configuration menusp.998.1.1 Export an nfs or smb sharep.1008.1.2 Remove an individual file-share Exportp.1028.1.3 Advanced file share configuration (expert mode)p.1039 Blade Maintenance and Firmware upgradesp.1059.1 Blade Maintenancep.1059.1.1 Backup your blade configurationp.1059.1.2 Import (restore) a blade configurationp.1069.2 ATCA Firmwarep.1069.2.1 Download New Firmware packagep.1079.2.1.1 Identifying the correct firmware imagep.1079.3 Normal Firmware Update proceduresp.107Web flash tool, update procedure detailsp.1079.3.2 flash_update.sh tool usage and optionsp.1099.3.3 CLI flash tool, update procedure detailsp.1109.4 Emergency firmware recovery, theory of operationp.1119.4.1 Jumper Settingsp.1119.4.2 Emergency flash recovery (factory reset)p.112Clear root passwordp.11310 ATCA-S201 Mechanical and Connector Informationp.11610.1 Specifications for the ATCA-S201p.11510.1.1 Physical dimensionsp.11510.1.2 Power Requirementsp.11510.1.3 Environmental Specifications and Compliancep.11510.1.4 NEBS Compliancep.11610.1.5 Electromagnetic Compliancep.11610.2 Connectors and Pin assignmentsp.11710.2.1 AMC Module Slotsp.11810.2.1.1 AMC Slot B1, Port Assignmentsp.11910.2.1.2 AMC slot B2, Port Assignmentsp.11910.2.1.3 Port Assignments for AMC Slot B3p.12010.2.1.4 AMC Slot B4, Port Assignmentsp.12010.2.2 Zone 1 Connectorsp.12010.2.3 Zone 2 Connectorsp.12110.2.4 Zone 3 Connectorsp.12210.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.12310.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignmentsp.12410.2.4.3 Connector J30, Power Supply for RTMp.12510.2.4.4 Connector J30, RTM Power Pin Assignmentp.12610.2.5 Power Supply Mezzanine Modulep.12710.2.6 SODIMM DDR Modulep.12711 RTM-ATCA-SXXX Overviewp.13311.1 Features of the Advanced Rear Transition Modulep.12811.2 I/O PICMG Standards Compliancep.12811.3 I/O Interfacesp.12811.3.1 External SAS Connectorp.12911.3.1.1 SAS Cable Lengthp.12911.3.2 Ethernet Management Port (RJ-45)p.12911.3.3 Serial Console Port (RJ-45)p.13011.4 LEDsp.13011.5 Software Supportp.13111.6 Products Supported by this Manualp.13111.7 Identification Labelsp.13112 RTM-ATCA-SXXX Installationp.13412.1 Installation and Removal of the Rear Transition Modulep.13412.2 Important Information about Your Chassisp.13412.2.1 Safety Statementp.13412.2.2 Observe Maximum Module Current Requirementsp.13412.3 Before You Install Or Remove The RTMp.13512.3.1 Observe ESD Precautionsp.13512.3.2 Watch for Bent Pins or Other Damagep.13512.4 Use Caution When Installing or Removing RTMp.13612.4.1 Preserve EMI Compliancep.13612.4.2 Understand Hot Swapp.13612.5 Verify Slot Usagep.13612.6 Installing the Advanced Rear Transition Modulep.13612.7 Removing the Advanced Rear Transition Modulep.13812.8 Verifying the Hardware Installationp.13813 RTM-ATCA-SXXX Mechanical and Connector Informationp.13913.1 Specifications for the RTM-ATCA-SXXXp.13913.1.1 Physical Dimensionsp.13913.1.2 Power Requirementsp.13913.1.3 Environmental Specifications and Compliancep.13913.1.4 NEBS Compliancep.14013.1.5 Electromagnetic Compliancep.14013.2 Connectors and Pin Assignmentsp.14113.2.1 SAS Connector Portp.14213.2.2 10/100/1000 Mb Management Portp.14313.2.3 Serial Console Management Portp.14413.2.4 Zone 3 Connectorsp.14413.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.14513.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignmentsp.14613.2.4.3 Connector J30, Power Supply for Advanced RTMp.14713.2.4.4 Connector J30, RTM Power Pin Assignmentp.14714 IPMI Functions Listp.14914.1 IPMI and Management Controller (IPMC)p.14914.2 Sensor data recordsp.14914.2.1 RTM e-Keying Port Assignmentsp.15114.3 Supported IPMI Commandsp.15215 IPMC Firmware Upgrade Procedurep.15415.1 The ipmitool utilityp.15416 Indexp.156
Page 10 of the Emerson ATCA-S201 user manual — Table of contents
Page 10 · click to enlarge
Page 10

Table of contents

1 ATCA-S201 Overviewp.171.1 Features of the ATCA Storage Modulep.171.2 I/O PICMG standards compliancep.181.3 Chassis I/O connectionsp.181.3.1 AMC card connectionsp.191.3.2 DDR2 SODIMMp.191.3.3 Zone 1, power backplane connectionsp.191.3.4 Zone 2, backplane connectionsp.191.3.5 Zone 3, Advanced RTM connectorp.191.3.5.1 Ethernet Management portp.201.3.5.2 Serial Console Portp.201.4 LEDsp.211.5 Software driver supportp.221.6 Part Number, Serial Number, and Address Labelsp.222 ATCA-S201 Installationp.242.1 Installation and removal of the ATCA carrier bladep.242.2 Important information about your chassisp.242.3 Safety Statementp.242.3.1 Observe maximum module current requirementsp.242.4 Before you install or Remove the ATCA carrier bladep.252.4.1 Observe ESD Precautionsp.252.4.2 Watch for Bent Pins or Other Damagep.252.5 Use Caution When installing or removing the ATCA carrierp.252.5.1 Preserve EMI Compliancep.252.5.2 Understand Hot Swapp.262.6 Connector Mechanical keyingp.262.7 Verify Slot Usagep.262.8 Installing the ATCA carrier bladep.262.9 Removing the ATCA carrier bladep.282.10 Verifying the Hardware Installationp.282.10.1 To Verify the Hardware Installationp.293 New System configurationp.30RS232 Console portp.313.1.1 System boot overviewp.313.1.2 Flash boot device contentsp.323.1.3 Linux serial console shell windowp.333.2 Default blade login accounts and passwordsp.33Password change procedurep.333.2.2 Password recovery procedurep.333.3 Factory resetp.343.4 Configuring a new ATCA-S201 bladep.343.4.1 Serial portsp.343.4.2 Ethernet portsp.343.4.3 Management Configuration via HTML browserp.35Management configuration via secure shell (SSH)p.353.4.5 Management configuration via serial console shellp.35Command line configuration toolp.363.5.1 Change IP address of any Ethernet resourcep.36Shell, configuration scripting optionsp.383.6 New system configuration, No DHCP serverp.39U-boot console toolp.403.6.1.1 When is U-boot needed?p.40Essential U-boot user commandsp.40U-boot environment variablesp.413.6.4 Manually assign management IP addressesp.423.7 Network boot procedurep.434 Network configurationp.444.1 Enable HTML browser accessp.454.2 HTML Security certificates (https:// )p.454.3 HTML login screenp.454.3.1 Auto logout inactivity periodp.464.3.1.1 Forced user logoutp.464.3.2 Single session management overridep.464.4 HTML home pagep.464.5 Essential System Configuration Stepsp.474.6 System Identification and Time Zone attributesp.484.6.1 Hostnamep.494.6.2 Domain Namep.494.6.3 Datep.494.6.4 Timep.504.6.5 Time Zonep.504.6.6 Name Server listp.514.6.7 NTP Server listp.514.6.8 Network time protocol - NTP (On/Off)p.524.6.9 Ethernet network port identificationp.524.6.10 Enable (online/offline)p.53DHCPp.53IP addressp.53Network (Subnet) maskp.53Broadcastp.54Gatewayp.54MTU sizep.544.6.17 MAC addressp.54VLAN Virtual Local Area Network supportp.55Viewing active VLANp.56Link aggregation and bondingp.574.8.1 Bonding, CLI command syntaxp.584.9 Shelf communicationsp.594.10 I/O Status attributesp.604.11 Blade maintenance, miscellaneous operationsp.614.11.1 Rescan SAS Topology, disk refreshp.624.11.2 Software Reset SAS Controllerp.624.11.3 Reset I/O Status countersp.624.12 CPU Status attributesp.634.13 ATCA Status attributesp.645 RAID Volume Configurationp.67Hardware RAID configurationp.675.1.1 JBOD modep.685.2 Hardware RAID configuration Menu usagep.685.2.1 Hardware RAID levels and capabilitiesp.705.2.2 How new RAID definitions alter device menu displayp.705.2.3 Modify existing RAID configurationsp.71Software RAID configurationp.735.3.1 Software RAID web-configuration menu usagep.735.3.2 Software RAID, CLI command syntaxp.74Software RAID levels and capabilitiesp.766 Prepare Logical Volumes for iSCSI or file sharingp.77Benefits of a logical Volume Group (/dev/vga)p.776.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)p.776.2 Viewing Physical disksp.786.2.1 Interpreting physical disk statusp.786.2.1.1 Disk view refresh, Re-draw Tree buttonp.796.2.1.2 Rescan SAS Topologyp.796.2.1.3 Software Reset SAS Controllerp.796.2.2 View physical disk propertiesp.79Create a logical Volume Group (/dev/vga)p.806.4 Creating a Logical Device (/dev/vga/lva0)p.83Extend/Expand a Logical Device (/dev/vga/lva0)p.83Delete a Logical device (/dev/vga/lva0)p.846.5 Manage shares (prepare logical device for service)p.856.5.1 Commit a logical drive for iSCSI servicep.856.5.2 Commit a logical drive for NAS servicep.866.5.3 Un-commit an iSCSI sharep.876.5.4 Un-commit an NFS/SMB sharep.886.6 Re-name iSCSI shares, make more ‘human-friendly’p.897 iSCSI device setup toolsp.90iSCSI configuration menup.907.1.1 Add or create an iSCSI targetp.90Add or create an iSCSI LUNp.91Remove an individual iSCSI LUNp.937.1.4 Delete an iSCSI Target (and all LUNS)p.937.1.5 Advanced iSCSI configuration (expert mode)p.947.1.6 iSCSI Discovery filter configuration (expert mode)p.988 NFS/SMB Share setup toolsp.99NFS and SMB mount point configuration menusp.998.1.1 Export an nfs or smb sharep.1008.1.2 Remove an individual file-share Exportp.1028.1.3 Advanced file share configuration (expert mode)p.1039 Blade Maintenance and Firmware upgradesp.1059.1 Blade Maintenancep.1059.1.1 Backup your blade configurationp.1059.1.2 Import (restore) a blade configurationp.1069.2 ATCA Firmwarep.1069.2.1 Download New Firmware packagep.1079.2.1.1 Identifying the correct firmware imagep.1079.3 Normal Firmware Update proceduresp.107Web flash tool, update procedure detailsp.1079.3.2 flash_update.sh tool usage and optionsp.1099.3.3 CLI flash tool, update procedure detailsp.1109.4 Emergency firmware recovery, theory of operationp.1119.4.1 Jumper Settingsp.1119.4.2 Emergency flash recovery (factory reset)p.112Clear root passwordp.11310 ATCA-S201 Mechanical and Connector Informationp.11610.1 Specifications for the ATCA-S201p.11510.1.1 Physical dimensionsp.11510.1.2 Power Requirementsp.11510.1.3 Environmental Specifications and Compliancep.11510.1.4 NEBS Compliancep.11610.1.5 Electromagnetic Compliancep.11610.2 Connectors and Pin assignmentsp.11710.2.1 AMC Module Slotsp.11810.2.1.1 AMC Slot B1, Port Assignmentsp.11910.2.1.2 AMC slot B2, Port Assignmentsp.11910.2.1.3 Port Assignments for AMC Slot B3p.12010.2.1.4 AMC Slot B4, Port Assignmentsp.12010.2.2 Zone 1 Connectorsp.12010.2.3 Zone 2 Connectorsp.12110.2.4 Zone 3 Connectorsp.12210.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.12310.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignmentsp.12410.2.4.3 Connector J30, Power Supply for RTMp.12510.2.4.4 Connector J30, RTM Power Pin Assignmentp.12610.2.5 Power Supply Mezzanine Modulep.12710.2.6 SODIMM DDR Modulep.12711 RTM-ATCA-SXXX Overviewp.13311.1 Features of the Advanced Rear Transition Modulep.12811.2 I/O PICMG Standards Compliancep.12811.3 I/O Interfacesp.12811.3.1 External SAS Connectorp.12911.3.1.1 SAS Cable Lengthp.12911.3.2 Ethernet Management Port (RJ-45)p.12911.3.3 Serial Console Port (RJ-45)p.13011.4 LEDsp.13011.5 Software Supportp.13111.6 Products Supported by this Manualp.13111.7 Identification Labelsp.13112 RTM-ATCA-SXXX Installationp.13412.1 Installation and Removal of the Rear Transition Modulep.13412.2 Important Information about Your Chassisp.13412.2.1 Safety Statementp.13412.2.2 Observe Maximum Module Current Requirementsp.13412.3 Before You Install Or Remove The RTMp.13512.3.1 Observe ESD Precautionsp.13512.3.2 Watch for Bent Pins or Other Damagep.13512.4 Use Caution When Installing or Removing RTMp.13612.4.1 Preserve EMI Compliancep.13612.4.2 Understand Hot Swapp.13612.5 Verify Slot Usagep.13612.6 Installing the Advanced Rear Transition Modulep.13612.7 Removing the Advanced Rear Transition Modulep.13812.8 Verifying the Hardware Installationp.13813 RTM-ATCA-SXXX Mechanical and Connector Informationp.13913.1 Specifications for the RTM-ATCA-SXXXp.13913.1.1 Physical Dimensionsp.13913.1.2 Power Requirementsp.13913.1.3 Environmental Specifications and Compliancep.13913.1.4 NEBS Compliancep.14013.1.5 Electromagnetic Compliancep.14013.2 Connectors and Pin Assignmentsp.14113.2.1 SAS Connector Portp.14213.2.2 10/100/1000 Mb Management Portp.14313.2.3 Serial Console Management Portp.14413.2.4 Zone 3 Connectorsp.14413.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignmentsp.14513.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignmentsp.14613.2.4.3 Connector J30, Power Supply for Advanced RTMp.14713.2.4.4 Connector J30, RTM Power Pin Assignmentp.14714 IPMI Functions Listp.14914.1 IPMI and Management Controller (IPMC)p.14914.2 Sensor data recordsp.14914.2.1 RTM e-Keying Port Assignmentsp.15114.3 Supported IPMI Commandsp.15215 IPMC Firmware Upgrade Procedurep.15415.1 The ipmitool utilityp.15416 Indexp.156
Page 11 of the Emerson ATCA-S201 user manual — Preface
Page 11 · click to enlarge
Page 11

Preface

Safety Summary

The following general safety precautions must be observed during all phases of operation, service, and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual could result in personal injury or damage to the equipment.

The safety precautions listed below represent warnings of certain dangers of which Emerson is aware. You, as the user of the product, should follow these warnings and all other safety precautions necessary for the safe operation of the equipment in your operating environment.

GROUND THE INSTRUMENT. To minimize shock hazard, the equipment chassis and enclosure must be connected to an electrical ground. If the equipment is supplied with a three-conductor AC power cable, the power cable must be plugged into an approved three-contact electrical outlet, with the grounding wire (green/yellow) reliably connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable meet International Electrotechnical Commission (IEC) safety standards and local electrical regulatory codes.

DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. Do not operate the equipment in any explosive atmosphere such as in the presence of flammable gases or fumes. Operation of any electrical equipment in such an environment could result in an explosion and cause injury or damage.

KEEP AWAY FROM LIVE CIRCUITS INSIDE THE EQUIPMENT. Operating personnel must not remove equipment covers. Only Factory Authorized Service Personnel or other qualified service personnel may remove equipment covers for internal subassembly or component replacement or any internal adjustment. Service personnel should not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable removed. To avoid injuries, such personnel should always disconnect power and discharge circuits before touching components.

USE CAUTION WHEN EXPOSING OR HANDLING A CRT. Breakage of a Cathode-Ray Tube (CRT) causes a high-velocity scattering of glass fragments (implosion). To prevent CRT implosion, do not handle the CRT, and avoid rough handling or jarring of the equipment. Handling of a CRT should be done only by qualified service personnel using approved safety mask and gloves.

DO NOT SUBSTITUTE PARTS OR MODIFY EQUIPMENT. Do not install substitute parts or perform any unauthorized modification of the equipment. Contact your local Emerson representative for service and repair to ensure that all safety features are maintained.

OBSERVE WARNINGS IN MANUAL. Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. You should also employ all other safety precautions which you deem necessary for the operation of the equipment in your operating environment.

To prevent serious injury or death from dangerous voltages, use extreme caution when handling, testing, and adjusting this equipment and its components. Warning

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide i

Page 12 of the Emerson ATCA-S201 user manual — Notice
Page 12 · click to enlarge
Page 12

Flammability

All Emerson PWBs (printed wiring boards) are manufactured with a flammability rating of 94V-0 by UL-recognized manufacturers.

EMI Caution

This equipment generates, uses, and can radiate electromagnetic energy. It may cause or be susceptible to electromagnetic interference (EMI) if not installed and used with adequate EMI protection.

Safety Statement

The ATCA-S201 is designed to comply with EN60950-1, and is intended to be used with similarly tested ATCA and AMC products that have a user’s guide detailing user installation of AMC module accessories.

CE Notice (European Community)

Emerson Networks products with the CE marking comply with the EMC Directive (89/336/EEC). Compliance with this directive implies conformity to the following European Norms:

EN55022 “Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment”; this product tested to Equipment Class A EN50082-1:1997 “Electromagnetic Compatibility–Generic Immunity Standard, Part 1. Residential, Commercial and Light Industry”

System products also fulfill EN60950 (product safety), which is essentially the requirement for the Low Voltage Directive (73/23/EEC).

Board products are tested in a representative system to show compliance with the above mentioned requirements. A proper installation in a CE-marked system will maintain the required EMC/safety performance.

In accordance with European Community directives, a “Declaration of Conformity” has been made and is on file within the European Union. The “Declaration of Conformity” is available on request. Please contact your sales representative.

Notice

While reasonable efforts have been made to assure the accuracy of this document, Emerson Networks, Inc. assumes no liability resulting from any omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.

Electronic versions of this material may be read online, downloaded for personal use. The text itself may not be published commercially in print or electronic form,

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide ii

Preface

Page 13 of the Emerson ATCA-S201 user manual
Page 13 · click to enlarge
Page 13

edited, translated, or otherwise altered without the permission of Emerson Networks, Inc.

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide iii

Preface

Page 14 of the Emerson ATCA-S201 user manual — Conventions Used in This Manual
Page 14 · click to enlarge
Page 14

About This Manual

This manual supports the following configurations and model numbers.

ATCA-S201 10GbE RAID Storage-IP Carrier blade

How this manual is organized

This manual is divided into the following chapters and appendices:

Chapter 1 provides a 6ATCA-S201 Overview

Chapter 2 provides instructions for Installation

Chapter 3 provides the procedures for a 6New System configuration

Chapter 4 Provides details regarding Network configuration

Chapter 5 provides details for RAID Volume Configuration

Chapter 6 provides instructions for sharing devices as NAS or iSCSI

Chapter 7 provides information for iSCSI LUN configurations

Chapter 8 provides information for NFS and SMB file sharing configurations

Chapter 9 provides 6Blade Maintenance and Firmware upgrades

Chapter 10 provides 6ATCA-S201 Mechanical and Connector Information

Chapter 11 provides overview on RTM-ATCA-SXXX

Chapter 12 provides instructions for installing the RTM-ATCA-SXXX

Chapter 13 provides RTM-ATCA-SXXX connector information

Chapter 14 provides 6IPMI Functions List

Chapter 15 provides 6IPMC Firmware Upgrade Procedure

Conventions Used in This Manual

The following typographical conventions are used in this document:

Table 1 Conventions used in this manual

Convention Is used for

bold User input that you type just as it appears; it is also used for commands, options and arguments to commands, and names of programs, directories and files.

italic Names of variables to which you assign values, for function parameters, and for structure names and fields. Italic is also used for comments in screen displays and examples, and to introduce new terms.

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide iv

Part Number Description

Page 15 of the Emerson ATCA-S201 user manual
Page 15 · click to enlarge
Page 15

courier System output (for example, screen displays and reports), examples, and system prompts.

ENTER The carriage return or Enter key.

CTRL The Control key. Execute control characters by pressing the CTRL key and the letter simultaneously, for example, Ctrl+D.

6806800H62B ATCA‐S201 Installation and Use Guide v

Page 16 of the Emerson ATCA-S201 user manual — Antistatic Precautions
Page 16 · click to enlarge
Page 16

Hardware Preparation and Installation

Unpacking Instructions

If the shipping carton is damaged upon receipt, request that the carrier’s agent be present during the unpacking and inspection of the equipment.

Unpack the equipment from the shipping carton. Refer to the packing list and verify that all items are present. Save the packing material for storing and reshipping of equipment.

Avoid touching areas of integrated circuitry. Static discharge can damage circuits.

After removing the product from the packaging:

Check for obvious physical damage. Make sure that you disconnect the chassis from the main power supply before you continue.

Antistatic Precautions

Emerson strongly recommends that you use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to electrostatic discharge (ESD). After removing the component from its protective wrapper or from the system, place the component flat on a grounded, static-free surface (and, in the case of a board, component side up). Do not slide the component over any surface.

If an ESD station is not available, you can avoid damage resulting from ESD by wearing an antistatic wrist strap (available at electronics stores) that is attached to an active electrical ground. Note that a system chassis may not be grounded if it is unplugged.

Avoid touching areas of integrated circuitry. Static discharge can damage these circuits.

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide vi

Page 17 of the Emerson ATCA-S201 user manual — 1.1 Features of the ATCA Storage Module
Page 17 · click to enlarge
Page 17

1 ATCA-S201 Overview

The Emerson ATCA-S201 is an ATCA carrier blade that supplies multi-protocol IP storage services to the chassis Zone-2 backplane using Ethernet connections. The ATCA-S201 virtualizes capacity of AMC SAS/SATA disks and creates multiple logical volumes which are mapped as iSCSI, NFS or SMB targets. Using access control lists, ATCA server blades are given authorization to connect with virtualized volumes via 10 GbE fabric or 1GbE base connections.

The ATCA-S201 carrier can accommodate up to four AMC disk modules. Additional disks may be added using an Advanced ARTM which adheres to the Advanced RTM zone-3 connector pin out.

Users may also deploy the ATCA-S201 to realize gateway functions with external equipment including SAS and/or Fiber channel (FC) storage area networks (SANs). For example, populate with an AMC 4 Gb FC controller modules, and establish gateway services between LUN volumes in the FC data center and the ATCA GbE network.

1.1 Features of the ATCA Storage Module

The ATCA-S201 is single slot carrier board for ATCA shelves. Measuring 8U (280mm) x 325 mm, the carrier includes four advanced mezzanine card (AMC) slots for storage disks or SAN connections. Several on board Ethernet controllers provide connections to the base and fabric interfaces.

The prominent digital components include:

Freescale® 1.3Ghz, super scalar PowerPC processor Intel® dual port 10 GbE Ethernet controller LSI® 8 port SAS controller, with RAID PLX® 48 Lane PCI Express Switch 1GB SODIMM, 533MHz DDR2, with ECC (72b) Carrier IPMC, with hot swap and LED control FRUID serial EERPORM (note: The FRU ID is not a separate part but rather embedded in the MMC controller.) Temperature sensors Voltage sensors SPI flash memory

The ATCA-S201 is loaded with software which enables it to terminate several IP protocols, and efficiently map these protocols to block I/O storage using SAS/SATA disks, and optional RAID protection. This product can also map IP protocols to Fibre Channel SAN resources, if populated with a 4Gb Fibre channel AMC module. Key software services include:

iSCSI service (IETF RFC-3720) NFS service version 3 (network file share) SMB service (Server Message Block file system) Integrated RAID0, RAID1 and RAID1E service SNMP HTML web configuration client

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 7

ATCA-S201 Overview

Page 18 of the Emerson ATCA-S201 user manual — 8 PCI-E
Page 18 · click to enlarge
Page 18

1.2 I/O PICMG standards compliance

The ATCA-S201 10Gb RAID Storage-IP Carrier ATCA is fully compliant with the following PCI Industrial Computer Manufacturers Group (PICMG) specifications:

PICMG 3.0 Advanced Telecommunications Computing Architecture (ATCA) PICMG 3.1 Ethernet for ATCA Systems AMC.0 Advance Mezzanine Card Base Specification AMC.1 PCI Express and Advanced Switching AMC.3 AMC Storage IPMI v1.5 Intelligent Platform Management Interface Specification PCI Express 1.0a

1.3 Chassis I/O connections

The ATCA-S201 provides several sockets and slots to facilitate operation in an ATCA chassis. In addition to 4 AMC modules, the module includes chassis backplane connections including ATCA zone-1 (power), zone-2 (fabric) and zone-3 (Advanced rear transition module).

8 PCI-E

Zone 3 to RTM

4 SATA/SAS

4 SATA/SAS x1 SAS

1 Gb 1 Gb

MPC8548E CPU

DDR2, FLASH 8 PCI-E

ATCA

10 Gb 10 Gb

8 PCI-E

8 PCI-E

X1 SAS

8 SAS

LSI 1068E SAS/RAID 8 PCIE

24 PCI-E

24 PCI-E

X1 SAS

IPMI (PPS)

X1 SAS

Show 19 more labels / short text on this page
ATCA‐S201 Overview · Site B1 · x4 PCI-E · 1 Gb · x1 SAS · Zone 2 · Site B2 · x4 PCI-E · x1 SAS · XAUI 10GigE · Site B3 · x4 PCI-E · x1 SAS · PLX8548 PCI-E Switch · Site B4 · Zone 1 Power · x4 PCI-E · x1 SAS · Power Module
Page 19 of the Emerson ATCA-S201 user manual — 1.3.5 Zone 3, Advanced RTM connector
Page 19 · click to enlarge
Page 19

Figure 1, ATCA-S201 functional block diagram

1.3.1 AMC card connections

The four AMC slots have identical features, and each accommodates a half width, mid height module. The ATCA-S201 accepts AMC cards conforming to either PCI express signaling (AMC.1) or Storage signaling options (AMC.3). AMC feature support details:

PCI-Express x4 on AMC ports 4-7 PCI reference clock on FCLKA 3Gb SAS/SATA on AMC port2 3Gb SAS/SATA on AMC port3 SAS hot swap support Face plate height x width, 18.96 x 73.8mm IPMB-L 72W max each slot (120W shared with all AMC slots)

1.3.2 DDR2 SODIMM

A 72 bit SODIMM socket is populated with a DDR2 memory module, and operated at 533MHz. The ATCA applies ECC (error correction code) algorithms to this memory to ensure data integrity of both the storage and program code stored in it. Single bit errors are automatically detected and corrected by these ECC algorithms.

1.3.3 Zone 1, power backplane connections

The Zone-1 connector brings 48V DC power into the ATCA main board. This power is regulated and split into several lower voltages by discrete components and a pair of power modules that are affixed to the ATCA carrier. Together, these devices convert 48V source and distributes power amongst the ATCA local onboard needs, AMC slots and advanced rear transition module (RTM).

1.3.4 Zone 2, backplane connections

This connector carries the Ethernet links to the chassis backplane. All Ethernet ports on this connector are full duplex and all ports support access to advertised storage resources. This connector includes the following Gigabit Ethernet ports:

2 Fabric channels, redundant 10GbE XAUI connections 2 Base channels, redundant 1GbE base connections

1.3.5 Zone 3, Advanced RTM connector

This connector conforms to the advanced rear transition module (RTM) 3-row connector standard. The following functions are routed to this connector:

8x PCI-express 4x SAS/SATA target connections 4x SAS/SATA initiator connections I2C support

ATCA‐S201 Overview

Page 20 of the Emerson ATCA-S201 user manual — 1.3.5.2 Serial Console Port
Page 20 · click to enlarge
Page 20

12V and 3.3V supply voltage 1GbE management RS232 management

1.3.5.1 Ethernet Management port

An Ethernet management port is routed to the Zone 3 connector. An advanced RTM with an RJ-45 connector is needed to access this port. The port auto negotiates to either 10/100/1000BASE-T.

1.3.5.2 Serial Console Port

An RS232 serial management port is routed to the Zone 3 connector. An advanced RTM with an RJ-45 connector is needed to access this port.

ATCA‐S201 Overview

Page 21 of the Emerson ATCA-S201 user manual — OK
Page 21 · click to enlarge
Page 21

1.4 LEDs

Several LEDs are located on the panel of the ATCA-S201 Advanced TCA Carrier.

Out of Service (OOS)

OK

Figure 2 Front view- fully populated ATCA-S201 showing panel LEDs

ATCA‐S201 Overview · Boot Status · Hot Swap

Page 22 of the Emerson ATCA-S201 user manual — 1.6 Part Number, Serial Number, and Address Labels
Page 22 · click to enlarge
Page 22

Table 2 LED functional description LED Description

Off: Normal, default state Blue-Blinking: Preparing for hot swap Blue-ON: ready for hot-swap removal ATCA Blade OK LED Green-ON: Blade Optimal

ATCA Hot Swap LED

ATCA Boot (Health) status AmberBlade is resetting Green: Blade is optimal
OffNormal, default state Yellow-Blinking: firmware update in progress Red-ON: Out of service (PPC/IPMC)

ATCA Out of service (OOS)

1.5 Software driver support

The ATCA-S201 provides several IP storage services over the 10GbE fabric and 1 GbE base connections. Major services include iSCSI, NFS, and SMB. ATCA node boards with standard OS installations, require no special drives from Emerson. This product is compatible with the following operating systems and services:

Solaris 10 (SPARC) Operating System, NFS Solaris 10 (SPARC) Operating System, iSCSI initiator Solaris 10 (x86) Operating system, NFS Solaris 10 (x86) Operating system, iSCSI initiator SuSE Linux Enterprise Server 10, NFS SuSE Linux Enterprise Server 10, iSCSI initiator RedHat Enterprise Linux 5.0_u4, NFS RedHat Enterprise Linux 5.0_u4, iSCSI initiator Windows Server 2003 CIFS (a dialect of SMB) Windows Server 2003, iSCSI initiator

1.6 Part Number, Serial Number, and Address Labels

At manufacturing time, several labels are affixed to the ATCA-S201 as shown below. For proper identification of the AMC module, use these barcode labels to determine the module identity. The barcode labels provide the following information:

Table 3 ATCA-S201 Identification Labels

Label 1Top/Final assembly P/N For Internal Use Only
Label 2Sub assembly P/N For Internal Use Only
Label 3Serial number (S/N)

AAA = Assembly Number (100)

FormatAAALYMMSSSS (example: 100S8031234)

L =Location of manufacturer (S)

Y = Calendar year of manufacturer (2008 = 8)

MM = Calendar month of manufacturer (March = 03)

SSSS = Sequence number (reset each month) (1234)

ATCA‐S201 Overview · Label Description

Page 23 of the Emerson ATCA-S201 user manual — ATCA-S120)
Page 23 · click to enlarge
Page 23
Label 4Part Numbers

This label contains 2 numbers:

(example:

Top = Internal Part Number

0106826G01A

Bottom = Orderable Part Number

ATCA-S120)

Emerson ATCA-S201 — ATCA-S120) diagram (page 23)
Fig. 3

Figure 3 ATCA-S201 Diagram Showing Identification Label Location

ATCA‐S201 Overview

Page 24 of the Emerson ATCA-S201 user manual — 2.3.1 Observe maximum module current requirements
Page 24 · click to enlarge
Page 24

2 ATCA-S201 Installation

This chapter contains the procedures for installing and removing the ATCA-S201 10GbE RAID storage services blade.

2.1 Installation and removal of the ATCA carrier blade

The ATCA-S201 10GbE RAID storage services blade can be installed into an ATCA shelf (chassis) with a midplane made for front and rear board installations.

2.2 Important information about your chassis

The Chassis backplane often designates certain slots as hub slots and the others as general purpose node slots. Be certain to select a general purpose node slot for installation. If this installation includes a companion advanced rear transition module (ARTM), install the ARTM first. These back-to-back slots have cut-outs that permit the front carrier board to pass signals to the ARTM via the Zone-3 connector complex.

Before installing the blade module, verify the module’s part number to ensure that the correct module is being installed into the system. For information on identifying the blade module, see Section 1.6 Part Number, Serial Number, and Address Labels.

2.3 Safety Statement

The ATCA-S201 is designed to comply with UL60950-1, and is intended to be used with similarly tested ATCA and AMC products that have a user’s guide detailing user installation.

2.3.1 Observe maximum module current requirements

Be sure to validate the host chassis, and the host chassis meets the maximum current requirements. The ATCA-S201 includes a stacked power supply module with maximum rated output of 210W of power. This represents a surplus of power vs. the expected power consumption.

Table 4 Max ATCA-S201 module Current requirements

Max ATCA blade Current Draw (unpopulated) 1.04 @ 48V (50 watts) Max current draw (each AMC slot) 72 watts (max each) Max current draw (ARTM slot) 25 watts (max)

2.08 @ 48V (100 watts) total shared power pool 3.12 Total Maximum

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 14

Module ATCA-S201

Page 25 of the Emerson ATCA-S201 user manual — 2.5.1 Preserve EMI Compliance
Page 25 · click to enlarge
Page 25

2.4 Before you install or Remove the ATCA carrier blade

Boards may be damaged if improperly installed or handled. Please read and follow the guidelines in this section to protect your equipment.

2.4.1 Observe ESD Precautions

Emerson strongly recommends that you use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to electrostatic discharge (ESD). After removing the component from its protective wrapper or from the system, place the component flat on a grounded, static-free surface (and, in the case of a board, component side up). Do not slide the component over any surface.

If an ESD station is not available, you can avoid damage resulting from ESD by wearing an antistatic wrist strap (available at electronics stores) that is attached to an active electrical ground. Note that a system chassis may not be grounded if it is unplugged.

2.4.2 Watch for Bent Pins or Other Damage

Bent pins or loose components can cause damage to the board, the backplane, or other system components. Carefully inspect your board and the backplane for both pin and component integrity before installation. Our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving our factory. Bent pins caused by improper installation or by boards with damaged connectors could void the warranty for the backplane or boards.

If a system contains one or more crushed pins, power off the system and contact your local sales representative to schedule delivery of a replacement chassis assembly.

2.5 Use Caution When installing or removing the ATCA carrier

When installing boards in an empty chassis, we recommend that you start at the left of the card cage and work to the right. This helps to avoid mistakes in matching slots with the intended carrier boards. When inserting or removing a board in a slot adjacent to other boards, use extra caution to avoid damage to the pins and components located on the primary or secondary sides of the boards.

2.5.1 Preserve EMI Compliance

To preserve compliance with applicable standards and regulations for electromagnetic interference (EMI), during operation all front and rear openings on

ATCA‐S201 Installation

Page 26 of the Emerson ATCA-S201 user manual — 2.8 Installing the ATCA carrier blade
Page 26 · click to enlarge
Page 26

the chassis or board faceplates must be filled with an appropriate card or covered with a filler panel. If the EMI barrier is open, devices may cause or be susceptible to excessive interference.

2.5.2 Understand Hot Swap

The ATCA module is electrically designed for hot swap within a fully powered chassis. To facilitate hot swap, there is a blue LED on the front faceplate. This LED is under software control of the IPMC managers.

The manager will illuminate the blue hot swap LED on the front faceplate when software has stopped and it is safe to remove the advanced rear transition module. If the blue-LED is not illuminated or blinking, it is not ready for removal. Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.

2.6 Connector Mechanical keying

The ATCA supports mechanical connector keying to help prevent installation with incompatible components and RTM. The ATCA carrier board utilizes an A1/K1 key that is set at for universal)

2.7 Verify Slot Usage

Prevent possible damage to module components by verifying the proper slot usage for your configuration.

In most cases, electronic keying (E-keying) will prevent power on of a board into an incompatible slot. However, as an extra precaution, you should be familiar with the slot purpose.

2.8 Installing the ATCA carrier blade

This section describes a recommended procedure for installing the ATCA carrier module in a chassis.

Before you install your module, please read all cautions, warnings, and instructions presented in this section.

Handling modules and peripherals can result in static damage. Use a grounded wrist strap, static-dissipating work surface, and antistatic containers when handling and storing components.

Insert the board by holding the Module Handles–do not exert unnecessary pressure on the faceplate.

Hot swap compliant modules may be installed while the system is powered on. If a module is not hot swap compliant, you should remove power to the slot or system before installing the module.

1. Verify that you have taken the necessary antistatic precautions.

ATCA‐S201 Installation

Page 27 of the Emerson ATCA-S201 user manual — 2.5.2 Understand Hot Swap
Page 27 · click to enlarge
Page 27
2. Go to the front of the system and choose an appropriate slot for the ATCA carrier blade. If also installing a companion advanced rear transition module (RTM), install it before installing the ATCA node board. For example, if the ATCA node board is planned for slot B4, first install the ARTM at the back of the system in slot B4.
3. Remove the slot filler panel from the selected node board slot, if necessary.
4. Prepare the module by loosening the locking screws and opening the injector/ejector latch at the top and bottom of the module as shown in the figure below.
Emerson ATCA-S201 — 2.5.2 Understand Hot Swap diagram (page 27)
Fig. 4 · 2.5.2 Understand Hot Swap

Figure 4 Injector / Ejector latch and locking screw

5. Carefully align the edges of the module with the guides in the appropriate slot. It might be helpful to look into the enclosure to verify correct alignment of the rails in the guides. Align the edges of the module with the card cage rail guides in the appropriate slot.
6. Taking care to keep the module aligned in the guides, apply equal and steady pressure and slide the module in until the injector/ejector mechanism engages the retention bars.
7. Position your thumbs at the top and bottom of the ATCA carrier board; simultaneously push in the module and rotate the injector/ejector mechanisms inward to their closed position to seat and secure ATCA carrier blade. DO NOT FORCE THE BOARD INTO THE SLOT.
8. Tighten the two module retention screws to secure the module into the shelf.

ATCA‐S201 Installation

Page 28 of the Emerson ATCA-S201 user manual — 2.10 Verifying the Hardware Installation
Page 28 · click to enlarge
Page 28
9. Power on the system, if necessary. Refer to your system manual for instructions on correctly powering on the system. Once power is applied to the chassis, the internal MMC controller runs a self-test that runs for approximately 10 seconds. Upon a successful power up self-test, the blue hot swap LED will blink and then turn off, indicating that the module has been placed in operation.

2.9 Removing the ATCA carrier blade

The ATCA-S201 ATCA carrier blade is hot-swappable and can be removed from a powered chassis. This section describes a recommended procedure for removing a board module from a chassis.

Before you remove your module, please read all cautions, warnings, and instructions presented in this section. Hot swap compliant modules may be removed while the system is powered on. When the lower ejector handle is partially disengaged, a mechanical switch will assert a signal to notify the IPMC to begin removal preparations. The IPMC will blink the blue hot-swap LED as it transitions the module to the appropriate power-down state. Upon completion and with permission from the ShMC, The blue LED will illuminate steady ON. This is the only indication that safe removal may commence. If the Blue LED is blinking or off, it is not ready for hot plug.

To remove the ATCA module, follow these steps:

1. Loosen the locking screws on the rear transition module.
2. Rotate the lower ejector handle to the half way (HW) position. Do not remove the module immediately.
3. If your host module running hot swap-aware software, the action of rotating the ejector lever will start the shutdown process on the board. The software will slowly blink the blue hot swap LED indicating the module is in the process of being de-activated.
4. Once the module has been de-activated, the Blue LED will illuminate steady. Once this is done you can extract the module by pulling on the module handle. Note: Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.
5. When the blue LED is illuminated ON, removal of the ATCA carrier board may proceed.
6. Carefully pull the module from the chassis.
7. If the card slot is to remain empty, install a filler panel in the slot.

2.10 Verifying the Hardware Installation

This section provides information to verify the installation of the ATCA-S201 10 GbE RAID storage services module.

ATCA‐S201 Installation

Page 29 of the Emerson ATCA-S201 user manual — 2.10.1 To Verify the Hardware Installation
Page 29 · click to enlarge
Page 29

2.10.1 To Verify the Hardware Installation

1. After power is applied to the system, wait approximately 45 seconds for firmware to initialize the board.
2. Inspect the LEDs on the front of the ATCA panel. When properly installed and powered, the LEDs will illuminate as follows: ATCA Hot Swap LED Off: Normal, default state ATCA Health status Green-blinking: Healthy, OK ATCA Out of service (OOS) Off: Normal, default state
3. (Optional). There are five Ethernet ports on the ATCA blade: 1 management (on RTM) 2 ATCA base ports (zone-2 connector) 2 ATCA fabric ports (zone-2 connector)

If DHCP is running on the network, it is possible to immediately ping the Ethernet ports on the ATCA module. Open a command line window on any node, and attempt to ping the ATCA blade. ok ping 192.168.1.xxx

ATCA‐S201 Installation · MAC address OUI · 00-11-0D-xx-xx-xx (hex)

Page 30 of the Emerson ATCA-S201 user manual — ATCA Chassis
Page 30 · click to enlarge
Page 30

3 New System configuration

Configuration Step:

Ethernet Comm. Setup

NFS / SMB Share Setup

This chapter describes how to establish management communications with the ATCA-S201 for purposes including initial configuration, administration and monitoring the storage services. A typical ATCA deployment will consist of an ATCA chassis, ATCA carrier blades, Advanced RTM and shelf management controllers (ShMC). Administrators may choose from the following physical access ports to conduct management communications:

Full configuration capabilities:

- RS232 on Advanced Rear transition module (ARTM) - Ethernet on Advanced Rear transition module (1 GbE on ARTM) - Any zone 2 Ethernet connection (base or fabric)

In addition to DHCP, the ARTM Ethernet port offers special protocol services such as TFTP to recover corrupted flash or accidental erasure. All available management communications methods are outlined in this chapter.

Emerson ATCA-S201 — Configuration Step: diagram (page 30)
Fig. 5 · Configuration Step:
Emerson ATCA-S201 — Configuration Step: diagram (page 30)
Fig. 6 · Configuration Step:

ATCA Chassis

Figure 5 Management communications port location diagram (Typical)

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 20

Show 8 more labels / short text on this page
RS232 Console Setup · RAID LUN Setup · Logical Volume · iSCSI Device Setup · Setup · Console (ShMC) · 1 GbE · Console (RS232)
Page 31 of the Emerson ATCA-S201 user manual — 3.1.1 System boot overview
Page 31 · click to enlarge
Page 31

3.1 RS232 Console port

This port is implemented on an RJ45 connector located on the ARTM that supplies RS232 console port access. As the ATCA-S201 boots, its progress can be monitored on the console.

By default, this port is set for VT100 terminal emulation as listed in the table below.

Table 5 Console port, default terminal settings Baud rate (bits per second) 115200 Data bits 8 Parity None Stop bits 1 Flow control Off

A serial interface can be established using a null modem cable and virtually any terminal communications tool. If using a PC running Microsoft® Windows®, the user may use HyperTerminal. On Linux-based systems, Minicom can be used.

3.1.1 System boot overview

The ATCA-S201 is designed to boot and become ready for management logins without any user intervention. This is possible only if the supporting network offers DHCP. The ATCA-S201 requires no disk drives for initialization. At manufacturing time, two duplicate copies of firmware code are pre-loaded on non-volatile flash components embedded on the carrier board. These firmware images include U- boot, a Linux kernel, and the root file system (rfs) which contains the storage application services. On power-up or reset, the blade inspects jumper positions to decide whether firmware is fetched from the customer flash or a read-only factory flash. This feature allows blade recovery in situations where the customer flash has been accidently erased or corrupted. The blade boot sequence continues as the onboard CPU loads firmware and executes the code contents. If no attempts are made to halt or suspend the boot process, approximately 45 seconds later, the module is able to accept management communication logins and commands. Once booted, the blade runs entirely out of DDR2 SRAM embedded on the blade. All Ethernet ports are configured for DHCP. If DHCP is not used on your network, the ATCA-S201 Ethernet ports must be initialized manually as described in section 3.6 of this manual.

Page 32 of the Emerson ATCA-S201 user manual — U-boot code
Page 32 · click to enlarge
Page 32
Emerson ATCA-S201 — 3.1.2 Flash boot device contents diagram (page 32)
Fig. 7 · 3.1.2 Flash boot device contents

Figure 6 ATCA Blade boot sequence diagram

3.1.2 Flash boot device contents

As mentioned in the previous section, the ATCA-S201 contains two flash images, which are preloaded with code at manufacturing. Each code image is divided into four major functional sections. Overtime, the customer may periodically updated individual sections with new code revisions, as outlined below:

Flash contents Source file name

U-boot code

U-boot.bin uImage Rootfs.ext.gz.uboot

Linux kernel code

File system code

User configuration settings

Figure 7 Boot-Flash device contents

Page 33 of the Emerson ATCA-S201 user manual — 3.2.2 Password recovery procedure
Page 33 · click to enlarge
Page 33

3.1.3 Linux serial console shell window

If the boot is not interrupted and has completed, the RS232 port accepts administrator login for Linux shell access, and access to command line configuration tools.

After successful login, the user may run any of the command line configuration tools presented in section 3.4.5.

3.2 Default blade login accounts and passwords

The ATCA-S201 includes two built-in user accounts for maintenance and management activities. Emerson recommends that administrators change the default passwords listed below for security purposes.

Table 6 Built-in user accounts included on a new ATCA-S201

User account Default password

admin admin The admin account was created for blade management activities. This account should be used for all management and configuration activities. Management logins may be performed via (1) Serial console RS232, (2) ssh or (3) secure html on any Ethernet port. root root The root account has master privileges with absolute power to modify the blades Linux OS in any way desired. It is unadvisable to use root as the normal user account because simple typographical errors, accidental file deletions, or generating unintentionally restrictive file permissions could render the blade in-operable, requiring the factory reset procedure. For normal activities, Emerson encourages using the admin user account and judicious use of the su command only when root privileges are really needed.

3.2.1 Password change procedure

The login password may be changed using the linux passwd command. For example, if logged in as root, the password change procedure is shown: #passwd Changing password for root Enter the new password (minimum of 5, maximum of 8 characters) Please use a combination of upper and lower case letters and numbers. Enter new password: xxxxxxx Re-enter new password: xxxxxxx Password changed. #

3.2.2 Password recovery procedure

In the event that the administrator login “root” is lost or forgotten, it is possible to clear it using jumpers provided on the ATCA-S201. The jumper location along with

Description

Page 34 of the Emerson ATCA-S201 user manual — 3.4.2 Ethernet ports
Page 34 · click to enlarge
Page 34

the clear password procedure is explained in section 9.4.3 of this manual. When invoked, the user is prompted to set a new one at first login.

3.3 Factory reset

Users can reset the blade to restore factory default settings. This procedure will erase all existing blade configurations (network settings, volumes, shares etc). The procedure is sometimes recommended following a major firmware upgrade.

i. Login into shell window as root

ii. At console prompt, typefw_setenv setfactorydefaults 1

3.4 Configuring a new ATCA-S201 blade

Initial configuration and setup of your blade may be conducted over Ethernet or serial (RS232) connections. Select the connection type that supports your preferred management style, either CLI (command line tool) or HTML as outlined below:

Connection type Command line tool Secure html tool

Serial/RS232 port on RTM Yes Ethernet port on RTM Yes Yes

Base or fabric ports on ATCA Zone-2 connector

3.4.1 Serial ports

An RJ45 serial port can be found on RTM panel. The default baud rate and communication settings are listed in Table 5 Console port, default terminal settings in section 3.1.2. The serial port attributes such as baud rate may be changed in the U-boot environment using the bootargs variable (see section 3.6.3 titled U-boot environment variables).

3.4.2 Ethernet ports

An RJ45 Ethernet port can be found on RTM panel. It auto negotiates Ethernet link speed s up to 1Gbps. Additional Ethernet ports (base and fabric) are provided on the ATCA zone-2 connector. By default, all Ethernet ports will attempt to obtain an IP address assignment form the DHCP (Dynamic Host Configuration Protocol) server on the network. Administrators must log into your DHCP server to determine the IP assignment. With the IP address, an administrator may connect to the ATCA-S201 using a secure shell (SSH) or an HTML browser which supports secure http connections. The Ethernet equipment can be identified by finding the IP address(es) corresponding to the following MAC address assignments:

Yes Yes · MAC address OUI · 00-11-0D-xx-xx-xx (hex)

Page 35 of the Emerson ATCA-S201 user manual — 3.4.5 Management configuration via serial console shell
Page 35 · click to enlarge
Page 35

3.4.3 Management Configuration via HTML browser

Once the IP address of the Ethernet port is known, an administrator may use a web browser to connect to the ATCA-S201 to perform and monitoring or configuration tasks. For security, the browser must support secure https connections on TCP port 443.

ExampleType this address into the address field of your web browser: https://192.168.1.xxx

Refer to chapter 4 , which begins the explanation and use of the html configuration tool.

3.4.4 Management configuration via secure shell (SSH)

Once the IP address of the Ethernet port is known, an administrator may use a SSH service to connect to the ATCA-S201 and to facilitate command line management.

For examplessh 192.168.1.211 –l admin

3.4.5 Management configuration via serial console shell

If the boot is not interrupted and has completed, the RS232 port accepts administrator login for Linux shell access, and access to command line configuration tools.

******************************************************* Welcome to the Emerson ATCA-S201 Storage Blade * Type atca_blade to manage this blade, or use the * * Web Based Management tool by browsing to: * * https://ipaddr where ipaddr is the network address * * of the blade. ******************************************************* WebHost.WebDomain login: admin Password:admin

After successful login, the user may run any the shell configuration tools presented in section 3.4.5.

Page 36 of the Emerson ATCA-S201 user manual — 3.5.1 Change IP address of any Ethernet resource
Page 36 · click to enlarge
Page 36

3.5 Command line configuration tool

This tool is available from either the RS232 console or a linux secure shell connection. After successful login, the user may run an executable file “atca_blade” located in the /web/cgi-bin directory. The tool provides the user with a simple menu interface, to perform interactive parameter modifications. A sample session is shown below. #ssh 192.168.1.xxx -l root [email protected]'s password: root Last login: Tue Nov 20 17:34:30 2007 from 192.168.1.xxx # cd /web/cgi-bin /web/cgi-bin # atca_blade

3.5.1 Change IP address of any Ethernet resource

The ATCA-S201 provides multiple Ethernet interfaces that host blades may use for initial setup and configuration. These ports are identified with the Linux resource labels shown in the table below

Table 7 Ethernet ports for chassis communications (base/fabric) Linux interface identifier description /dev/eth0 Chassis Base port 0, 1Gb link /dev/eth1 Chassis Base port 1, 1Gb link /dev/eth2 RTM, Rear I/O management port. /dev/eth3 Chassis fabric port 0, 10Gb XAUI link /dev/eth4 Chassis fabric port 1, 10Gb XAUI link

Perform manual Interactive changes

After invoking the command line tool (atca_blade), the user can modify any of the parameters within the functional groupings listed above. For example, select the “2. Network Settings” group. The configuration tool will display the entire list parameters in the group, along with their present values. Main Page for CLI Interface 1. IPMI Settings (get_status) 2. Network Settings (set_network) 3. Hardware Raid Configuration (set_raid) 4. Logical Volume Mangager LVM2 Configuration (set_lvm2) 5. Manage Shares (set_shares) 6. smb Configuration (set_smb) 7. nfs Configuration (set_nfs) 8. iSCSI Configuration (set_iscsi) 9. Web gui enable (set_gui) 10. Allow Web and CLI at the same time (set_useroverride) 0. Exit Enter choice [1-10], 0 to exit: [0]: 2

System Identification and TimeZone Active Settings Hostname=[BladeHost]: DomainName=[Emerson.com]

Page 37 of the Emerson ATCA-S201 user manual — Command line configuration tool
Page 37 · click to enlarge
Page 37

Date=[12/19/2007]: Time=[17:25:07]: TimeZone=[US/Eastern]: NTPServer[0]=[209.132.176.4]: NTPServer[1]=[64.22.86.210]: NTPServer[2]=[]: NTPServer[3]=[]: NTPServer[4]=[]: Use Network Time Protocol(NTP)=[y]: eth0 Network Configuration enable0=[0]: ipaddr0=[dhcp]: netmask0=[0.0.0.0]: broadcast0=[0.0.0.0]: gateway0=[0.0.0.0]: nameserver0=[0.0.0.0]: hwaddr0=[00:08:2b:00:11:22]: MTU0=[1500]: eth1 Network Configuration enable1=[0]: ipaddr1=[dhcp]: netmask1=[0.0.0.0]: broadcast1=[0.0.0.0]: gateway1=[0.0.0.0]: nameserver1=[0.0.0.0]: hwaddr1=[00:08:2b:00:11:23]: MTU1=[1500]: eth2 Network Configuration enable2=[1]: ipaddr2=[192.168.1.211]: netmask2=[255.255.255.0]: broadcast2=[192.168.1.255]: gateway2=[192.168.1.1]: nameserver2=[192.168.1.10]: hwaddr2=[00:08:2b:00:11:24]: MTU2=[1500]: eth3 Network Configuration enable3=[0]: ipaddr3=[dhcp]: netmask3=[0.0.0.0]: broadcast3=[0.0.0.0]: gateway3=[0.0.0.0]: nameserver3=[0.0.0.0]: hwaddr3=[00:08:2b:00:11:25]: MTU3=[9000]: eth4 Network Configuration enable4=[0]: ipaddr4=[dhcp]: netmask4=[0.0.0.0]: broadcast4=[0.0.0.0]: gateway4=[0.0.0.0]: nameserver4=[0.0.0.0]: hwaddr4=[00:08:2b:00:11:26]: MTU4=[9000]: Change Network Settings? [n]:

Page 38 of the Emerson ATCA-S201 user manual — 3.5.2 Shell, configuration scripting options
Page 38 · click to enlarge
Page 38

At this point the user may inspect the list. If the user wishes to modify any of the listed values, enter ‘y’ at the above prompt. The configuration utility will then display each parameter, one at a time. The user may accept the default input by pressing the ENTER key, or enter a replacement value. In the example below, the user will change the Hostname for the blade. Change Network Settings? [n]: y System Identification and TimeZone Active Settings 0: Hostname=[BladeHost]: STOR200 Changing Hostname= from Emerson1 to STOR200 1: DomainName=[Emerson.com]: 2: Date=[12/19/2007]: ... 48: enable4=[1]: 49: dhcp4=[0]: 50: ipaddr4=[192.168.44.11]: 51: netmask4=[255.255.255.0]: 52: broadcast4=[192.168.44.255]: 53: gateway4=[192.168.44.1]: 54: hwaddr4=[00:11:0D:D0:08:04]: 55: MTU4=[9000]:

In the previous example, the user elected to change the hostname from Emerson1 to STOR200. Also note, the tool prints a index number preceding each parameter. Hit the Enter key to proceed through the rest of the list. After displaying the final parameter, the configuration tool presents the user with two questions: Save New Network Settings? [y]: n Change Network Settings? [n]: n

Configuration tool question Possible responses

Save New Network Settings? y, changes are immediately applied, and all changes are stored in non-volatile ram flash device. This action ensures the changes are remembered after reboot.

n, do not store changes in NVRAM

Change Network Settings? y, changes are immediately applied, but new values are NOT stored in non- volatile flash device. They will revert to previous stored on rebbot.

n, discard the changes, and return to the main menu.

3.5.2 Shell, configuration scripting options

The “atca_blade” tool supports scripted invocations, to apply a fixed set of parameter values from a file. Such files would contain a pre-determined set of

Page 39 of the Emerson ATCA-S201 user manual — 3.6 New system configuration, No DHCP server
Page 39 · click to enlarge
Page 39

responses that are applied to the tool in a macro fashion. A script allows the user to modify one or several parameters in one step.

SYNOPSIS atca_blade menu_page_index index_skip+ new_value [+ ] [+]

DESCRIPTION

atca_blade may be called via shell script or batch file to make “un- manned” changes to parameter values used to configure ATCA-S201 IP and RAID service behaviors.

OPTIONS menu_page_index: designates the menu subgroup to be modified. The menu sub- group numbers are displayed when the tool is manually invoked with no arguments from the console window. The menu_group_number and index_skip are combined to create a pointer to a specific parameter position. The following menu_page_index syntax may be used interchangeably:

1|get_status 2|set_network 3|set_raid 4|set_lvm2 5|set_ms 6|set_smb 7|set_nfs 8|set_iscsi 9|set_gui 10|set_useroverride

y|n: Certain commands require affirmation to make changes. Example: ”Change Network Settings? [n]:”.

index_skip+: represents index leap ahead. The tool parses this value, and increments the index pointer by the amount indicated.

+: end of input (a plus symbol, with no integer). Indicates that the input line is complete, and requested changes can be committed.

Example #1: Use this script entry to change the blades Hostname. atca_blade set_network Y 0+ StorageBlade_99 +

Example #2: Additional references.

Specific CLI usage and syntax examples are provided within each configuration chapter of this manual.

3.6 New system configuration, No DHCP server

In some deployments, a DHCP server may not exist. In these instances the blades Ethernet resources will require manual initialization.

Menu_page_index|equivalent_pagename

Page 40 of the Emerson ATCA-S201 user manual — 3.6.2 Essential U-boot user commands
Page 40 · click to enlarge
Page 40

3.6.1 U-boot console tool

The ATCA-S201 employs a staged boot process that begins with U-boot. U-boot is an open source boot loader program that is the first code executed at system reset. As the boot execution commences, its progress may be monitored via the RS232 console port of the Advanced RTM. U-boot supplies several initialization parameters to the Linux kernel that administrators may elect to modify. U-boot employs a countdown timer with a default setting of bootdelay seconds, see table below. If a key is pressed before this time, the auto boot procedure halts and the administrator will see a U-Boot command prompt: ... Hit any key to stop autoboot: 5 uboot=>

3.6.1.1 When is U-boot needed?

Users may never need the U-boot environment. U-boot is included to accommodate atypical system maintenance situations such as:

On site field servicing (must be connected via serial console) Network boot (rather than flash boot) Environments without a DHCP server Flash recovery

3.6.2 Essential U-boot user commands

The U-boot console environment includes a rich set of commands that can be listed on the screen using the following command: uboot=> help

Typically, only a handful of commands are needed to configure a new ATCA-S201. The essential commands are covered in the table below.

Table 8 Essential U-boot configuration commands

U-boot command syntax description

printenv Displays a list of all U-boot environment variables and their current values. See section 3.6.3 for details.

setenv

Used to create or modify a U-boot environment variable. New variables will be automatically created, existing ones overwritten. When called without a <new value>, it will delete the matching <variable_name> from the U-boot environment if it exists.

saveenv Used to saves environment variables to flash device, which is loaded upon subsequent system power cycle or reboot.

Variable changes that are not saved exist in RAM only,

Page 41 of the Emerson ATCA-S201 user manual — 3.6.3 U-boot environment variables
Page 41 · click to enlarge
Page 41

U-boot command syntax description

and lost if the system is re-booted.

ping Sends an icmp echo address to the designated IP address (entered in dotted decimal format)

reset Perform soft reset of the ATCA cpu, forcing a system reboot.

run Run a sequence of commands defined in the environment <variable_name>, for example:

version Displays the version and build date of the U-boot image running on ATCA blade.

3.6.3 U-boot environment variables

Administrators may display the full list of environment variables using the printenv command. U-boot includes the following environment variables with pre-assigned factory default settings.

Table 9 U-boot environment variables shown with printenv Variable name Default value Description bootcmd run flashboot This variable defines a command string that is automatically executed when the initial bootdelay countdown is not interrupted. flashboot A sequence of commands, set at manufacturing time. If in the U-boot console, use run flashboot to boot the ATCA using the images contained in flash. This command sequence is executed automatically by bootcmd in a normal power-up. ramboot A sequence of commands, set at manufacturing time. If in the U-boot console, use run ramboot to boot the ATCA from the serverip node. nfsboot A series of startup commands, set at manufacturing time. RESERVED for future use. bootdelay 5 U-boot will wait this number of seconds before it executes the bootcmd variable. After reset, a countdown message is printed to the serial console. Pressing any key will interrupt normal boot and display the U-boot console prompt. Value 0 =boot without delay. Value -1 = disable autoboot, always enter U-boot console baudrate 115200 RS232 Serial port baud rate, default=115200 (decimal) (Max: 115200) loads_echo 1 If set to 1, all characters received during a serial download (using the loads command) are echoed to the serial console. rootpath /nfsroot RESERVED for future use. hostname Not used

uboot=> run flashboot

Page 42 of the Emerson ATCA-S201 user manual — 3.6.4 Manually assign management IP addresses
Page 42 · click to enlarge
Page 42

Variable name Default value Description bootfile Uimage This is the filename name of the Linux kernel image. loadaddr 1000000 Specifies the starting memory address for storing the bootfile consoledev ttyS1 Settings for kernel console port. bootargs root=/dev/ram rw ramdisk_size=200000 console=ttyS1,9600

Command line passed to the Linux kernel. May contain nested references, which will be resolved at runtime.

Ramdiskaddr 2000000 Specifies the starting memory address of the Linux ramdisk. ramdisksize 2000000 Specifies the memory size reserved for the Linux ramdisk. initrd_high 0xfffffff Forces ramdisk to load at a high memory address (do not modify) othbootargs Used to pass Ethernet MAC and SAS address assignments to Linux. ramdiskfile rootfs.ext2.gz.uboot Specifies name of rfs (root file system) image fetched by U-boot when booting from the tftp server (serverip). eth0addr 00:11:0D:xx:xx:xx MAC address of 1 GbE port on ATCA Zone-2 base-0 eth1addr 00:11:0D:xx:xx:xx MAC address of 1 GbE port on ATCA Zone-2 base-1 eth2addr 00:11:0D:xx:xx:xx MAC address of 1 GbE port on ATCA Zone-3 Management port eth3addr 00:11:0D:xx:xx:xx MAC address of 10 GbE port on ATCA Zone-2 fabric-0 eth4addr 00:11:0D:xx:xx:xx MAC address of 10 GbE port on ATCA Zone-2 fabric-1 sasaddr 50:00:00:11:OD:xx:xx:xx WWN address of SAS controller, port0. Port 1 is WWN+1, Port2 is WWN+2 and so on. ipaddr 0.0.0.0 Dotted decimal IP address applied to active Ethernet management port (ethact) gatewayip 0.0.0.0 Dotted decimal Default network gateway netmask 0.0.0.0 Dotted decimal network mask stdin serial Specifies RS232 console port for input messages stdout serial Specifies RS232 console port for output messages stderr serial Specifies RS232 console port for error messages serverip 0.0.0.0 Dotted decimal IP address of TFTP server ethact At boot, ethprime is copied to ethact.

Ethact identifies which Ethernet resource is associated with U-boot services. Permissible values: eTSEC0= Zone2 connector, Base0 Ethernet (1Gbps) eTSEC1= Zone2 connector, Base1 Ethernet (1Gbps) eTSEC2= Zone3 connector, Management port (1Gbps) Note: ethact may be dynamically changed at the U-boot console, but it is not a persistent variable, and will be reloaded at next boot. netdev eth2 RESERVED for future use ethprime eTSEC2 At boot, ethprime is copied to ethact. Refer to ethact for a list of permissible values.

3.6.4 Manually assign management IP addresses

Administrators may individually modify any of the listed U-boot environment variables. Note these changes are not permanently recorded in the non-volatile flash unless saved using saveenv. Extreme care should be taken to ensure new values are valid entries.

Page 43 of the Emerson ATCA-S201 user manual — Flash contents Source file name
Page 43 · click to enlarge
Page 43

To manually establish IP port address, a typical new system configuration might consist of the following commands: uboot=> setenv ipaddr 192.168.1.211 uboot=> setenv gatewayip 192.168.10.1 uboot=> setenv netmask 255.255.255.0 uboot=> setenv ethprime eTSEC2

Once all of the environment variables have been modified they persist only if permanently recorded in the flash device. This is accomplished with this command: uboot=> saveenv

This example setup establishes initializes the 1Gb Ethernet port located on the RTM for administrator login and management access.

3.7 Network boot procedure

The ATCA-S201 supports network boot which allows the user to bypass code contained on the embedded flash devices, and instead load code images contained on the network. Network boot does not replace stored user configurations. Network boot requires that the network node supports tftp and must contain the following source files located in directory named /tftpboot/:

Flash contents Source file name

U-boot.bin uImage Rootfs.ext.gz.uboot

... Hit any key to stop autoboot: 5 uboot=> run ramboot

Show 4 more labels / short text on this page
U-boot code · Linux kernel code · File system code · User configuration settings
Page 44 of the Emerson ATCA-S201 user manual — HW RAID
Page 44 · click to enlarge
Page 44

4 Network configuration

Configuration Step:

Ethernet Comm. Setup

NFS / SMB Share Setup

This chapter explains how to configure the IP ports for external host access. The ATCA-S201 offers 5 Ethernet ports within the ATCA environment, as follows:

Two 10Gb XAUI fabric ports (zone-2) Two 1Gb base ports (zone-2) One 1Gb management port (zone-3)

SiteB1

HW RAID

SiteB2

IP host 1:1 mapping (JBOD)

SiteB3

1:1 mapping (JBOD)

SiteB4

Storage is ultimately served out over these IP ports using iSCSI, NFS and SMB protocols. Administrators may individually enable and configure these ports. Configuration can be done using the serial console port, Telnet or via HTML. This chapter assumes the reader is familiar with internet protocols and TCP/IP networking.

Show 25 more labels / short text on this page
RS232 Console Setup · RAID LUN Setup · Logical Volume · iSCSI Device Setup · Setup · AMC disk · Physical · Logical groups · iSCSI & NAS · modules · disks · & volumes · iSCSI · LUNs · sda · vga · Zone-2 Fabric · IP network · Zone-2 Base · sdb · NFS share points · Zone-3 RTM · vgz · sdc · CIFS share points
Page 45 of the Emerson ATCA-S201 user manual — 4.3 HTML login screen
Page 45 · click to enlarge
Page 45

4.1 Enable HTML browser access

The web browser configuration tool may be enabled or disabled for security reasons.

Table 10 CLI command syntax, enable/disable GUI access Convention atca_blade set_gui + < enable> 0|1 Value 0 disables the GUI, value 1 enables the GUI.

4.2 HTML Security certificates (https:// )

The user may perform HTML configuration with any browser that supports https . Direct your browser to the any active IP port on the ATCA-S201. The ATCA-S201 employs https (encrypted secure sockets layer- SSL) technology to protect configuration activity that occurs over IP links. The ATCA-S201 issues a self-signed certificate, identified as “EMERSON”. This certificate is not registered with a certificate authority, and the browser will pop up a warning as shown below. Users must accept the certificate to proceed.

Emerson ATCA-S201 — 4.2 HTML Security certificates (https:// ) diagram (page 45)
Fig. 8 · 4.2 HTML Security certificates (https:// )
Emerson ATCA-S201 — 4.2 HTML Security certificates (https:// ) diagram (page 45)
Fig. 9 · 4.2 HTML Security certificates (https:// )
Emerson ATCA-S201 — 4.2 HTML Security certificates (https:// ) diagram (page 45)
Fig. 10 · 4.2 HTML Security certificates (https:// )
Emerson ATCA-S201 — 4.2 HTML Security certificates (https:// ) diagram (page 45)
Fig. 11 · 4.2 HTML Security certificates (https:// )

4.3 HTML login screen

A user login is required to access and operate the ATCA-S201 storage blade. This menu prompts the user for username and password. When shipped from the factory, the default entries are username=admin, password=admin. See section 3.2.1for the information on the Password change procedure.

StorBlade99 ATCA-S201 Enter Username and Password

Username:

Password:

CLI command syntax · Submit

Page 46 of the Emerson ATCA-S201 user manual — 4.4 HTML home page
Page 46 · click to enlarge
Page 46

4.3.1 Auto logout inactivity period

The system will automatically terminate (logout) a remote user after 10 minutes of in-activity. Optionally, the user can create this file to set an alternate inactivity threshold value (expressed in seconds):

# echo 60 >/etc/max_inactivity

4.3.1.1 Forced user logout

A local user may immediately terminate an active management session by deleting the following file:

# rm /tmp/curruser

The above command will require the remote user to re-login, or allow the administrator to launch the atca_blade CLI tool locally.

4.3.2 Single session management override

Blade management is restricted to one admin user at a time, thus preventing blade configuration conflicts from multiple remote locations. Moreover, a user may not simultaneously operate the atca_blade CLI tool with the web GUI configuration tool.

Users may optionally override this protection mechanism using either of the following mechanisms:

Refer to page 55, Table 24 ATCA status indication, for the instructions to enable this override “Allow GUI and CLI”.

Table 11 CLI command syntax, single session management override Convention atca_blade set_useroverride <enable> +

< enable> 0|1 Value 0 disables the GUI, value 1 enables the GUI.

4.4 HTML home page

Once logged in, the user will see the start-up screen shown in the figure below. Left click the folder panel to expand the menu configuration tools.

Emerson ATCA-S201 — 4.4 HTML home page diagram (page 46)
Fig. 12 · 4.4 HTML home page

Web GUI command · CLI command syntax · Emerson ATCA-S201 +

Page 47 of the Emerson ATCA-S201 user manual — 4.5 Essential System Configuration Steps
Page 47 · click to enlarge
Page 47
Emerson ATCA-S201 — 4.5 Essential System Configuration Steps diagram (page 47)
Fig. 13 · 4.5 Essential System Configuration Steps
Emerson ATCA-S201 — 4.5 Essential System Configuration Steps diagram (page 47)
Fig. 14 · 4.5 Essential System Configuration Steps
Emerson ATCA-S201 — 4.5 Essential System Configuration Steps diagram (page 47)
Fig. 15 · 4.5 Essential System Configuration Steps
Emerson ATCA-S201 — 4.5 Essential System Configuration Steps diagram (page 47)
Fig. 16 · 4.5 Essential System Configuration Steps
Emerson ATCA-S201 — 4.5 Essential System Configuration Steps diagram (page 47)
Fig. 17 · 4.5 Essential System Configuration Steps
Emerson ATCA-S201 — 4.5 Essential System Configuration Steps diagram (page 47)
Fig. 18 · 4.5 Essential System Configuration Steps
Emerson ATCA-S201 — 4.5 Essential System Configuration Steps diagram (page 47)
Fig. 19 · 4.5 Essential System Configuration Steps
Log Off Usernameadmin

Figure 8 HTML tool, startup screen

4.5 Essential System Configuration Steps

Once connected to html configuration page, it is essential that the user navigate to both the Network and Shelf configuration pages. Proper interaction with the blade cannot occur without completing these configuration steps:

Page 48 of the Emerson ATCA-S201 user manual — 4.6 System Identification and Time Zone attributes
Page 48 · click to enlarge
Page 48
Emerson ATCA-S201 — 4.6 System Identification and Time Zone attributes diagram (page 48)
Fig. 20 · 4.6 System Identification and Time Zone attributes

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance Network Shelf I/O Status CPU Status ATCA Status

Submit All Network Changes Add New VLAN VLAN Index Interface

HostName DomainName Date Time TimeZone Nameservers NTP Server List Use NTP

Active Settings StorBlade99 domain.com 4/6/2009 08:51:59 New_York 0.0.0.0 tick.usask.ca tock.usask.ca y

IPAddress Network Mask Broadcast Gateway MTU Size MAC Address

IPAddress Network Mask Broadcast Gateway MTU Size MAC Address

IPAddress Network Mask Broadcast Gateway MTU Size MAC Address

New Settings DHCP Enable dhcp 1500 0.0.0.0 0.0.0.0 0.0.0.0

IPAddress Network Mask Broadcast Gateway MTU Size MAC Address

New Settings DHCP Enable 192.168.43.11 9000 192.168.43.255 255.255.255.0 192.168.43.1

IPAddress Network Mask Broadcast Gateway MTU Size MAC Address

New Settings DHCP Enable 192.168.44.11 9000 192.168.43.255 255.255.255.0 192.168.44.1

Figure 9 Emerson ATCA-S201 Maintenance Network

Use the mouse to navigate and make changes to an item in the “new settings” row. Notice that changes made here do not immediately change the “Active settings” row. New settings changes are abandoned by navigating away from the page. Changes are committed only when the “submit” button is clicked.

4.6 System Identification and Time Zone attributes

The attributes in this menu grouping establish time reference utilized by all aspects of product operation.

Submit

Page 49 of the Emerson ATCA-S201 user manual — 4.6.3 Date
Page 49 · click to enlarge
Page 49

System Identification and TimeZone

HostName DomainName Date Time TimeZone Nameservers NTP Server List Use NTP

Active Settings StorBlade99 domain.com 4/6/2009 08:51:59 New_York 0.0.0.0 tick.usask.ca tock.usask.ca y

New Settings NTP StorBlade99 domain.com tick.usask.ca 4/6/2009 08:51:59 New_York

ˇ 0.0.0.0

4.6.1 Hostname

The user may assign a human friendly name to the ATCA-S201 instance. The hostname is printed at the top of all menus, and listed in configuration and logs files. Users are encouraged to assign different hostnames to each blade; however there is no actual requirement to make unique assignments within a namespace.

Table 12 CLI command syntax, set network property: hostname Convention atca_blade set_network Y 0+ <hostname> +

< hostname> Any combination of letters or digits, no spaces

4.6.2 Domain Name

The user may use this field to specify the registered domain name in which the product will operate (e.g. emerson.com or example.net). In practice, this name should be officially assigned and recorded with the domain name registrar.

Table 13 CLI command syntax, set network property: domain name Convention atca_blade set_network Y 1+ <domain> +

Argument represents new domain name, e.g. yourdomain.com

4.6.3 Date

The user may manually adjust the system date, if NTP is NOT enabled. Date must be entered as month/day/year. (e.g. 3/15/2008).

CLI command syntax · CLI command syntax

Page 50 of the Emerson ATCA-S201 user manual — 4.6.5 Time Zone
Page 50 · click to enlarge
Page 50

Table 14 CLI command syntax, set network property: system date Convention atca_blade set_network Y 2+ <date> +

Date format MM/DD/YYYY, (month,day,year)

4.6.4 Time

The user may manually adjust the system time, if NTP is NOT enabled. Date must be entered as hours/minutes/seconds. (e.g. 14:51:59 to indicate 2:51 PM and 59 seconds).

Table 15 CLI command syntax, set network property: system time Convention: atca_blade set_network Y 3+ <time> +

hh:mm:ss (for example, 01:23:45), where hh (00 to 23), mm and ss (00 to 59)

4.6.5 Time Zone

World Time references are synchronized with GMT. The drop-down time zone field allows the user to choose a city matching the physical deployment region and daylight savings observance. To minimize code size, only one city per world time zone was chosen. The valid list of drop down field are shown in Table 17 Time Zone Selections.

Table 16 CLI command syntax, set network property: system time zone Convention: atca_blade set_network Y 4+ <zone> +

Pick from list in Table 17 Time Zone Selections. E.g. New_York, Chicago etc.

CLI command syntax · CLI command syntax · CLI command syntax

Page 51 of the Emerson ATCA-S201 user manual — 4.6.7 NTP Server list
Page 51 · click to enlarge
Page 51

Table 17 Time Zone Selections

Emerson ATCA-S201 — 4.6.6 Name Server list diagram (page 51)
Fig. 21 · 4.6.6 Name Server list

London WET -Western European GMT+1 Paris CET — Central European GMT-1 GMT+2 Athens EET — Eastern European GMT-2 GMT+3 Moscow BT - Baghdad GMT-3 St_Johns GMT+4 GMT-4 Halifax AST - Atlantic Standard GMT+5 GMT-5 New_York EST — Eastern Standard GMT+6 GMT-6 Chicago CST — Central Standard Denver MST - Mountain Standard GMT+7 GMT-7

Phoenix GMT+8 Taipei CCT — China Coast GMT-8 Los_Angeles PST — Pacific standard GMT+9 Tokyo JST — Japan Standard GMT-9 Anchorage YST — Yukon Standard GMT+10 Sydney GST — Guam Standard GMT- 10 Honolulu HST - Hawaiian Standard

4.6.6 Name Server list

Name servers must be specified using dotted decimal notation. For redundancy purposes, the user may specify up to five servers, each separated by a comma.

Table 18 CLI command syntax, set network property: assign Name server Convention: atca_blade set_network Y 5+ <server1> … [server5]+

Enter one to five name servers, specified as Dotted decimal addresses.

4.6.7 NTP Server list

NTP servers must be specified using dotted decimal notation. For redundancy purposes, the user may specify multiple servers, each separated by a comma. At manufacturing time, this field is seeded with two NTP servers:

64.22.86.210 209.132.176.4

CLI command syntax · …

Page 52 of the Emerson ATCA-S201 user manual — 4.6.9 Ethernet network port identification
Page 52 · click to enlarge
Page 52

Table 19 CLI command syntax, set network property: assign NTP server Convention: atca_blade set_network Y 10+ <server1> … [server5]+

Enter one to five NTP servers, specified as Dotted decimal or domain addresses (time.nist.gov)

4.6.8 Network time protocol - NTP (On/Off)

Users may enable NTP protocol service to synchronize the ATCA- S201’s clocks with a known good reference time source.

4.6.9 Ethernet network port identification

The ATCA-S201 provides multiple Ethernet interfaces that host blades may use to access storage. Whether using the CLI or web based configuration tools, these ports are identified with the Linux resource labels shown in the table below

Table 20 Ethernet ports for chassis communications (base/fabric) Linux interface identifier Port Description /dev/eth0 10/100/1000 — Base 0 (Zone -2) /dev/eth1 10/100/1000 — Base 1 (Zone -2) /dev/eth2 10/100/1000 — Management (RTM, Rear I/O management port) /dev/eth3 10G — Fabric 0 (Zone-2 XAUI ) /dev/eth4 10G — Fabric 1 (Zone-2 XAUI )

The webtool provides a table for each Ethernet resource. Users may enter new settings for any field, and click the submit button located at the top of the screen to apply the settings.

IPAddress Network Mask Broadcast Gateway MTU Size MAC Address

Active Settings 192.168.200.32 255.255.255.0 192.168.200.255 192.168.200.1 1500 00:11:0D:xx:xx:xx

New Settings DHCP Enable dhcp 1500 0.0.0.0 0.0.0.0 0.0.0.0

CLI command syntax · … · Management[eth#] Network configuration

Page 53 of the Emerson ATCA-S201 user manual — 4.6.13 Network (Subnet) mask
Page 53 · click to enlarge
Page 53

Table 21 CLI command syntax, set network property: Ethernet port configuration Convention: atca_blade set_network Y + Use portcode 16+ to modify eth0

Use portcode 24+ to modify eth1 Use portcode 32+ to modify eth2 Use portcode 40+ to modify eth3 Use portcode 48+ to modify eth4 Use portcode 52+ to modify VLAN 0|1 Value 0 disables the port, value 1 enables the port. 0|1 Value 0 disables dhcp, value 1 enables the dhcp. When enabled, other network input fields are ignored. (ipaddr, netmask etc.) Remaining

ipaddr, netmask input formats etc. are defined in the sections below

4.6.10 Enable (online/offline)

The user may set a port online or offline with this menu box. When enabled the port in online, and will terminate IP traffic. When the port is disabled, IP packets are not processed.

4.6.11 DHCP

The user may configure any port for Dynamic Host Configuration Protocol (DHCP). If DHCP is enabled, the port will search for a DHCP server to automatically set the IP address, subnet mask, default gateway address.

4.6.12 IP address

The user may manually assign the IP address of a port, if DHCP is NOT enabled. The address must be entered using dotted decimal notation. (e.g. 192.168.1.211)

4.6.13 Network (Subnet) mask

The user may manually assign the subnet mask of a port, if DHCP is NOT enabled. The subnet mask must be entered using dotted decimal notation. (e.g. 255.255.255.0)

CLI command syntax · inputs

Page 54 of the Emerson ATCA-S201 user manual — 4.6.17 MAC address
Page 54 · click to enlarge
Page 54

4.6.14 Broadcast

< Read/Write > The user may manually assign the broadcast address for a port, if DHCP is NOT enabled. The broadcast address must be entered using dotted decimal notation. (e.g. 192.168.1.255)

4.6.15 Gateway

The user may manually assign the default gateway for a port, if DHCP is NOT enabled. The default gateway must be entered using dotted decimal notation. (e.g. 192.168.1.1)

4.6.16 MTU size

The MTU defaults to 1500 bytes on each IP interface, but the user can adjusted higher if that size that is also supported by all adapter, switch, and router devices in the path. Any path component with a smaller MTU will break packets into pieces (fragment), which can reduce overall system performance. The user may specify the MTU (Maximum Transmission Unit) for each Ethernet resource. Linux interface Port Description Max MTU size /dev/eth0 10/100/1000 — Base 0 (Zone -2) 9586 /dev/eth1 10/100/1000 — Base 1 (Zone -2) 9586 /dev/eth2 10/100/1000 — Management (RTM port) 9586 /dev/eth3 10G — Fabric 0 (Zone-2 XAUI ) 16110 /dev/eth4 10G — Fabric 1 (Zone-2 XAUI ) 16110

MTU defines the maximum size of a packet that the blade may transmit over the network interface without fragmentation. A large MTU permits the system to send fewer packets of a larger size to achieve the same network throughput, with generally less OS and software overhead.

If you are not sure, you can often find the MTU size using a trial-and-error ping command. First set the MTU to the max, then open a console port, and ping the destination port, incrementing the size until no response is received:

ping 192.168.1.10 –l 1500 –f ping 192.168.1.10 –l 4000 –f ping 192.168.1.10 –l 8000 –f … ping 192.168.1.10 –l 16110 –f

4.6.17 MAC address

The Ethernet MAC address is a 48-bit number that identifies the physical source and destination of the Ethernet 802.3 frame. The address is assigned by Emerson during manufacturing, and permanently recorded in nonvolatile memory on the blade.

Page 55 of the Emerson ATCA-S201 user manual — # atca_blade set_network Y 52+ 1
Page 55 · click to enlarge
Page 55

4.7 VLAN Virtual Local Area Network support

Users may configure assign any of the Ethernet ports available on the ATCA-S201 to a Virtual Local Area Networking (Virtual LAN, IEEE 802.1q).

The webtool provides a entry for to define new VLAN. Users choose a physical interface from the drop down menu (etho, eth1..eth4) and assign a VLAN index. Click the submit button to apply the settings.

StorBlade99 ATCA-S201 Network Configuration

Submit All Network Changes Add New VLAN VLAN Index Interface

ˇ

Users may also configure VLANs using a console window and the Linux vconfig tool.

vconfig offers a rich set of feature options. The section below explains only the minimal options to add or remove a VLAN definition. Consult the Linux manpages for more details.

SYNOPSIS vconfig [add|rem] [options]

DESCRIPTION

vconfig is a program which enables the user to create and remove vlan devices.

OPTIONS add [interface-name] [vlan-id]

Creates a vlan-device on [interface-name]. The resulting vlan-device will be

called according to the naming convention set. Users should avoid using [vlan-id]= 1. Many hardware products use [vlan-id] 1 as the management vlan. See linux manpage ‘vconfig’ for more information.

Removes the named vlan-device.

Example #1add a vlan interface to XAUI port 4, ID 66

# vconfig add eth4 66 # ifconfig eth4.66 up Finally, enable the VLAN, and commit to system flash memory:

# atca_blade set_network Y 52+ 1

Show 4 more labels / short text on this page
0 eth0 · Submit · CLI command syntax · rem [vlan-device]
Page 56 of the Emerson ATCA-S201 user manual — # ifconfig eth4.66
Page 56 · click to enlarge
Page 56

Convention: atca_blade set_network Y Use VLANindex 52+ to modify 1st VLAN definition

Use VLANindex 60+ to modify 2nd VLAN definition Use VLANindex 68+ to modify 3rd VLAN definition Increment index by 8 for each additional VLAN definition 0|1 Value 0 disables the port, value 1 enables the port. Other prompts Other prompts will follow.

Example #2Remove vlan interfaces on XAUI port 4, ID 66

Disable the VLAN port (see notes above for explanation of )

# atca_blade set_network Y <VLANindex> 0 + # vconfig rem eth4.66 Permanently remove VLAN port from system flash memory. Edit file to remove 12 lines for VLAN entry # vi /etc/network.conf

Example: remove these 12 lines: # net interface 6 ifconfig eth4 up if [ `grep eth4.66: /proc/net/dev -c` -ne 1 ]; then vconfig add eth4 66 ; fi HWADDR[6]="" SYSCFG_IFACE[6]=y INTERFACE[6]="eth4.66" IPADDR[6]="5.5.5.5" NETMASK[6]="255.255.255.0" BROADCAST[6]="4.4.4.255" GATEWAY[6]="0.0.0.0" MTU[6]="1500" IF_NAME[6]="VLAN Network Port 6"

4.7.1 Viewing active VLAN

Each VLAN is enumerated within the management web-tool and CLI tools. Open the network page. Each VLAN appears as Port Description [eth#].[vlan-id] Network Configuration

Example #2list vlan interfaces on XAUI port 4, ID 66

# ifconfig eth4.66

Page 57 of the Emerson ATCA-S201 user manual — Storage Blade
Page 57 · click to enlarge
Page 57

4.8 Link aggregation and bonding

The ATCA-S201 supports 802.3ad link aggregation also known as “bonding”. Bonding allows you to aggregate multiple Ethernet ports into a single group, effectively combining the bandwidth into a single connection. For example, you can aggregate the ATCA base channel ports (1 Gb/s each) into a trunk group, providing 2Gb/s cumulative bandwidth, fault tolerance and load balancing.

Emerson ATCA-S201 — 4.8 Link aggregation and bonding diagram (page 57)
Fig. 22 · 4.8 Link aggregation and bonding
Emerson ATCA-S201 — 4.8 Link aggregation and bonding diagram (page 57)
Fig. 23 · 4.8 Link aggregation and bonding

Base channel bonding example

Storage Blade

Host Blade

The Linux bonding driver provides the ability to group ports, detect link failures and reroute traffic to the surviving ports in a manner transparent to the storage participants.

Figure 10 Link aggregation 802.3ad (bonding), theory of operation

Show 11 more labels / short text on this page
Base channel · Switch 1 · bonding · Host · Eth0 · Eth0 · Bond0 · Bond0 · Eth1 · Switch 2 · Eth1
Page 58 of the Emerson ATCA-S201 user manual — /etc/rc.d/init.d/userstart
Page 58 · click to enlarge
Page 58

4.8.1 Bonding, CLI command syntax

The Linux community has created an extensive man page for ifenslave. The subset of essential elements is summarized below.

1. ifconfig eth0 down; ifconfig eth1 down

Deactivate the Ethernet “slave” ports that will become bond members Step2: modprobe bonding mode=0 miimon=100

This loads the bonding module, sets the usage policy mode and sets polling frequency to 100mS. Several mode exist, but these are the most common Valid mode=[ ] options:. mode=0 - Round robin packet, or balanced transmit policy. This mode will only work with switches that support trunking.

mode=1- Active-backup; one slave port is active, the other is passive. This mode should work with any Layer-II switch.

3. ifconfig bond0 up Define a new bond0, and assign a dotted decimal . Note: the MAC address of the bond0 device will be taken from the first slave device. Step4: ifenslave bond0 eth0; ifenslave bond0 eth1 Assign the slave ports that will comprise the new bond.

Preserve new bond attributes

/etc/rc.d/init.d/userstart

This file contains a template for adding commands that will be executed on boot (or shutdown) as required by the user. This file is stored in system flash memory and preserved over reboots. Edit this file and add the entire sequence of bond commands.

Example:

ifconfig eth0 down; ifconfig eth1 down modprobe bonding mode=0 miimon=100 ifconfig bond0 <ip-address> up ifenslave bond0 eth0; ifenslave bond0 eth1 eth1

1. ifenslave -d bond0 eth0; ifenslave -d bond0 eth1 Remove all Ethernet “slave” ports that are bond members Step2: ifconfig eth0 down; ifconfig eth1 down Set the former slave ports as down. Step3: /etc/rc.d/init.d/userstart

Remove the relevant bond creation code, and reboot

Create new bond · Remove bond

Page 59 of the Emerson ATCA-S201 user manual — Blade Number IPMB‐Address (Hex)
Page 59 · click to enlarge
Page 59

4.9 Shelf communications

Use these menus to initialize a communication path with the chassis shelf manager, and properly monitor ATCA-S201 hardware.

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance Network Shelf I/O Status CPU Status ATCA Status

StorBlade99 ATCA‐S201 Shelf Configuration

Blade 1 (Primary) Configuration

Blade Number IPMB‐Address (Hex)

Active Settings 1 0x96

Blade 2 (Expander) Configuration

Shelf Address

Shelf Primary Address Shelf Alternate Address

Active Settings 192.168.100.32 127.0.0.1

New Settings

192.68.100.32 127.0.0.1

Blade Number IPMB‐Address (Hex)

Active Settings 2 0x84

New Settings 2

Figure 11 HTML tool, Emerson ATCA-S201 MaintenanceShelf

Show 12 more labels / short text on this page
‐ · Emerson ATCA-S201 · + · + · + · + · + · + · + · + · ‐ · Submit
Page 60 of the Emerson ATCA-S201 user manual — 4.10 I/O Status attributes
Page 60 · click to enlarge
Page 60

Table 22 Shelf configuration menu parameters

Shelf Address Primary/Secondary Address

Active Settings Current IP address of chassis shelf manager New Settings This field is used to assign a new IP address for the chassis shelf manager. User must hit “submit” to update the value.

Blade 1 Configuration IPMB-Address (Hex) for ATCA-S201

Active Settings Slot number and Hex address code corresponds to the physical slot where the ATCA-S201 blade is installed. The value is self-discovered, where Slot0=0x82, Slot1=0x84 … Slot13=0x9C, Slot14=9E

Blade 2 Configuration IPMB-Address (Hex) for slave expansion blade

Active Settings The ATCA-S201A may be paired with companion blade to add additional hardware resources such as additional hard drives Supported companion blades include the Emerson ATCA1020 JBOD and ATCA1010 PCIe expansion blades. This Hex address code corresponds to the physical slot where the companion blade is installed. Slot0=0x82, Slot1=0x84 … Slot13=0x9C, Slot14=9E. New Settings This field is used to assign a slot address for the blade. User must hit “submit” to update the value.

4.10 I/O Status attributes

The items in this menu provide real-time information about the I/O activity occurring on physical disks connected to the ATCA-S201 raid controller. Disks may reside in any of the four AMC slots, RTM, or expansion JBOD products. Disks are identified by the Linux device designation /dev/sdx, highlighted in gray.

Emerson ATCA-S201 — 4.10 I/O Status attributes diagram (page 60)
Fig. 24 · 4.10 I/O Status attributes

Maintenance Network Shelf I/O Status CPU Status ATCA Status

/dev/sda Current I/Os / sec Current MBytes / sec Total MBytes

/dev/sdb Current I/Os / sec Current MBytes / sec Total MBytes

Figure 12 HTML tool, Emerson ATCA-S201 MaintenanceIO Status

Status item Description

Page 61 of the Emerson ATCA-S201 user manual — 4.11 Blade maintenance, miscellaneous operations
Page 61 · click to enlarge
Page 61

Table 23 Blade, I/O Status indication

Emerson ATCA-S201 — 4.11 Blade maintenance, miscellaneous operations diagram (page 61)
Fig. 25 · 4.11 Blade maintenance, miscellaneous operations

Current I/Os / sec Bar graphs provided for each disk

Read Displays the number of real-time read I/O per second (read IOPS). Write Displays the number of real-time write I/O per second (write IOPS). Total Displays the cumulative number of real-time I/O activity (read and write).

Counter Mbytes / sec Numeric counters provided for each disk

Total Displays the cumlative real-time bandwidth, displayed megabytes/second Total Mbytes Numeric counters provided for each disk

Read/write/Total 128 bit counter displays the number of bytes transferred since reset.

4.11 Blade maintenance, miscellaneous operations

These menus provide several miscellaneous operations that are useful for blade management and monitoring. The base page lists detailed versioning information of the loaded software as shown below:

Emerson ATCA-S201 — 4.11 Blade maintenance, miscellaneous operations diagram (page 61)
Fig. 26 · 4.11 Blade maintenance, miscellaneous operations

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

Emerson ATCA-S201 — 4.11 Blade maintenance, miscellaneous operations diagram (page 61)
Fig. 27 · 4.11 Blade maintenance, miscellaneous operations

Linux 2.6.23 #28 Wed Jul 1 09:09:29 EDT 2009

Show 11 more labels / short text on this page
Emerson ATCA-S201 · ‐ · + · + · + · + · + · + · + · + · +
Page 62 of the Emerson ATCA-S201 user manual — 4.11.3 Reset I/O Status counters
Page 62 · click to enlarge
Page 62

4.11.1 Rescan SAS Topology, disk refresh

The physical disk assignments change as disks become utilized in a RAID definitions. Use the “Re-Draw Tree” button to rescan for physical disks, and refresh the menu view.

4.11.2 Software Reset SAS Controller

The button will issue a software-reset signal to the embedded SAS controller. If users have hot-swapped many disks, this ensures the SAS controller has completely purged internal tables, and is properly presenting the new or remaining disks to the operating system.

Software reset SAS controller

4.11.3 Reset I/O Status counters

This button will reset all I/O status counters.

Rescan SAS topology

Page 63 of the Emerson ATCA-S201 user manual — 4.12 CPU Status attributes
Page 63 · click to enlarge
Page 63

4.12 CPU Status attributes

This screen displays real-time statistics for the applications running on ATCA-S201’s PowerPC processor. The data on this screen is derived from the Linux top command (man top), formatted to fit the HTML window. The screen auto refreshes approximately every 6 seconds.

StorBlade99 ATCA-S201 Current CPU Status top - 13:27:48 up 21:05, 1 user, load average: 0.03, 0.02, 0.00 Tasks: 61 total, 1 running, 60 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 1034688k total, 228964k used, 805724k free, 185084k buffers Swap: 0k total, 0k used, 0k free, 14496k cached

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance Network Shelf I/O Status CPU Status ATCA Status

PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 17888 root 20 0 2456 1136 916 R 1.0 0.1 0:00.02 top 1 root 20 0 3876 808 680 S 0.0 0.1 0:07.44 init 2 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kthreadd 3 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 ksoftirqd/0 4 root 15 ‐5 0 0 0 S 0.0 0.0 0:09.15 events/0 5 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.01 khelper 69 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kblockd/0 76 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 ata/0 77 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 ata_aux 126 root 20 S 0.0 0.0 0:00.00 pdflush 127 root 20 S 0.0 0.0 0:00.34 pdflush 128 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kswapd0 129 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 aio/0 130 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 cifsoplockd 131 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 cifsdnotifyd 132 root 20 S 0.0 0.0 0:00.02 crypto 133 root 20 S 0.0 0.0 0:00.00 crypto_ret 163 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 pciehpd 496 root 20 0 7080 2032 1692 S 0.0 0.2 0:00.30 sshd 500 root 20 0 2668 1356 1132 S 0.0 0.1 0:00.01 sh 830 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 rpciod/0 851 root 20 0 3876 628 500 S 0.0 0.1 0:00.02 klogd

874 root 30 10 S 0.0 0.0 0:00.00 jffs2_gcd_m

877 root 30 10 S 0.0 0.0 0:00.54 jffs2_gcd_m

td0 894 root 16 ‐4 1788 560 484 S 0.0 0.1 0:00.04 udevd 956 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.20 mpt_poll_0 960 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.01 mpt/0 972 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 scsi_eh_0 1351 root 20 0 3876 628 504 S 0.0 0.1 0:00.36 syslogd 1440 root 15 ‐5 0 0 0 S 0.0 0.0 0:00.00 kjournald

Figure 13 HTML tool, Emerson ATCA-S201 MaintenanceCPU Status

Show 12 more labels / short text on this page
‐ · Emerson ATCA-S201 · + · + · + · + · + · + · + · + · ‐ · td3
Page 64 of the Emerson ATCA-S201 user manual — 4.13 ATCA Status attributes
Page 64 · click to enlarge
Page 64

4.13 ATCA Status attributes

The items in this menu provide operational condition of the ATCA-S201 and the four AMC slots and RTM if installed.

Maintenance Network Shelf I/O Status CPU Status ATCA Status

StorBlade99 ATCA-S201 Blade 1 (0x96) Status

Vendor IANA ID Name HW Revision

H8 FW Revision IPMI Rev Model Serial

Emerson 65cd ATCA‐S201 0004 01.10 01.50 ATCA‐S201 100LYMMSSSS

AMC Site B1 (0x7a) Configuration Phy Num Type SAS Address Handle Parent Disk 00 SAS 5000cca000784c49 0009 0001 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B2 (0x7c) Configuration Phy Num Type SAS Address Handle Parent Disk 01 SAS 500000e016cbd032 000a 0002 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B3 (0x7e) Configuration Phy Num Type SAS Address Handle Parent Disk 02 SAS 5000c50005b18665 000b 0003 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B4 (0x80) Configuration Phy Num Type SAS Address Handle Parent Disk 03 SAS 500000e016cbd982 000c 0004 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B5 (0x8e) Configuration Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson RTM 0106828G 401NYMxxx Enabled True Site Control

Figure 14 HTML tool, Emerson ATCA-S201 MaintenanceATCA Status

Show 14 more labels / short text on this page
‐ · Refresh · Reboot · Power Off · Enable · Disable · Enable · Disable · Enable · Disable · Enable · Disable · Enable · Disable
Page 65 of the Emerson ATCA-S201 user manual — 4.13 ATCA Status attributes
Page 65 · click to enlarge
Page 65

Table 24 ATCA status indication

PCI state Collection of values pertaining to AMC modules with PCI devices

Vendor 4 digit Hex value representing the PCI Vendor ID . Device 4 digit Hex value representing the PCI device ID . SVID 4 digit Hex value representing the PCI sub-system vendor ID . (set to 0000 for non-PCI modules) SSID 4 digit Hex value representing the PCI sub-system device ID . (set to 0000 for non-PCI modules) Bus/Slot/Func Displays the OS assignments for bus, slot, and function of the PCIe device. (set to 0000 for non-PCI modules)

AMC state Collection of values pertaining to AMC modules with PCI devices

Vendor FRU data retrieved from the management device; it indicates the manufacturer of the device. Product FRU data retrieved from the management device; it indicates the product name.

Model FRU data retrieved from the management device; it indicates the model name.

Serial FRU data retrieved from the management device; it indicates the serial number.

State Indicates whether the AMC module is enable or disabled.

Present Indicates the present pin is asserted, indicated the presence of a module

MgEna Indicates management enable is asserted on the AMC

MgOK Indicates management power is detected on the AMC

PayEna Indicates payload enable is asserted on the AMC

PayOK Indicates payload power is detected on the AMC

‘Radio button’ when selected will eliminate the majority of ‘pop-up’ confirmations that precede major configuration changes.

‘Radio button’ will allow an administrator to operate the GUI and CLI simultaneously.

Allow GUI and CLI

This button will redraw the display window.

This button will reboot the storage blade, and all storage served by this blade will be unavailable. The Blade will terminate all applications and shutdown its internal OS. The blade will automatically reboot, by executing the uboot, kernel and applications loaded in its flash memory.

This button will power down the storage blade, and all storage served by this blade will be unavailable. The Blade will terminate all applications and shutdown its internal OS. When the sequence completes all hot-swap LED indicators will illuminate “Blue”. Manual operator action will be required to reboot the blade.

This button will enable AMC sites. When enabled, the menu will show the AMC state as Enabled.

This button will disable AMC sites. When disabled, the menu will show the AMC state as Disabled.

Show 8 more labels / short text on this page
Status item Description · Button usage · Suppress Warnings · Refresh · Reboot · PowerOff · Enable · Disable
Page 66 of the Emerson ATCA-S201 user manual — 4.13 ATCA Status attributes
Page 66 · click to enlarge
Page 66

Table 25 CLI command syntax, blade_status for ATCA and AMC site status Convention: atca_blade get_status 2 +

Display ATCA blade revision information Convention: atca_blade get_status 1 <site> +

1 |2|3|4|5 Display site status: 1=Site B1, 2=Site B2, 2=Site B3, 2=Site B4, 2=Site B5 (RTM)

CLI command syntax

Page 67 of the Emerson ATCA-S201 user manual — 5.1 Hardware RAID configuration
Page 67 · click to enlarge
Page 67

5 RAID Volume Configuration

Configuration Step:

Ethernet Comm. Setup

NFS / SMB Share Setup

This chapter explains how to prepare and configure RAID volumes that are ultimately mapped to the various IP services advertised on the ATCA-S201 ATCA carrier board. These virtual RAID volumes are created from in-chassis storage pools comprised of AMC modules with SAS or SATA disks. Hardware RAID services are available for disk striping (RAID0) and extended volume mirroring (RAID1, RAID1E). Software RAID services are available for parity based disk striping algorithms including RAID4, RAID5 and RAID6. The Software RAID features of this product can provide better capacity utilization efficiency, but can consume a greater percentage of CPU and system memory bandwidth.

SiteB1

HW RAID

SiteB2

IP host 1:1 mapping (JBOD)

SiteB3
SiteB4

1:1 mapping (JBOD)

5.1 Hardware RAID configuration

Administrators will use two inter-related menus to enable and configure the hardware RAID features of ATCA-S201. These configuration tools appear within the html tool’s main navigation panel on the left side as shown in the figure below.

Emerson ATCA-S201 Hardware RAID Emerson ATCA-S201 Physical Disks

Show 25 more labels / short text on this page
RS232 Console Setup · RAID LUN Setup · Logical Volume · iSCSI Device Setup · Setup · AMC disk · Physical · Logical groups · iSCSI & NAS · modules · disks · & volumes · iSCSI · LUNs · sda · vga · Zone-2 Fabric · IP network · Zone-2 Base · NFS share points · sdb · vgz · Zone-3 RTM · sdc · CIFS share points
Page 68 of the Emerson ATCA-S201 user manual — 5.2 Hardware RAID configuration Menu usage
Page 68 · click to enlarge
Page 68
Emerson ATCA-S201 — 5.1.1 JBOD mode diagram (page 68)
Fig. 28 · 5.1.1 JBOD mode

Shares LVM2 LVM2 Configuration MD RAID Configuration Hardware RAID Configuration Physical Disks /dev/sda /dev/sdb /dev/sdc /dev/sdd /dev/sde /dev/sdf /dev/sdg Maintenance

Figure 15 HTML tool, Main navigation side-bar, Hardware RAID->Configuration

These menus are used to view and arrange the hardware disk pool. The hardware disk pool is the raw (unformatted/unassigned) disk capacity or resources available to a ATCA-S201. In SNIA terminology, these are primordial disks. This storage is block I/O comprised of the following:

1. AMC SAS/SATA hard drive(s)
2. RTM SAS/SATA hard drive(s)
3. Disks or volumes accessed via an AMC SAS controller
4. Disks or volumes access via an AMC FC controller

The sum capacity of the hardware disk pool resources equals the total size of storage available to the particular ATCA-S201.

5.1.1 JBOD mode

Just a bunch of disks (JBOD) is a term to describe disks which are not part of a RAID or logical device definition. By default, a new ATCA-S201 will scan and display all discovered disks 1:1 in the physical disk menu. These disks may be used as-is, or grouped using the configuration tools to create RAID or combined logical volumes.

5.2 Hardware RAID configuration Menu usage

On a new system installation, this configuration menu enables the creation of RAID disk(s) that will appear in the physical disk menu. Once created, RAID disks are managed in the same manner as other physical disks, but boast benefits including improved performance and redundancy.

Page 69 of the Emerson ATCA-S201 user manual — 5.1.1 JBOD mode
Page 69 · click to enlarge
Page 69
Emerson ATCA-S201 — 5.1.1 JBOD mode diagram (page 69)
Fig. 29 · 5.1.1 JBOD mode

Disk Name Parent Host Bus Target Lun Vendor Product Rev Size Select

1 /dev/sda md0 HITACHI HUC101414CSS300 A410 140205MB

2 /dev/sdb md0 0 0 1 0 HITACHI HUC101414CSS300 A410 140205MB

3 /dev/sdc unknown 0 0 2 0 HITACHI HUC101414CSS300 A410 140205MB

4 /dev/sdd unknown 0 0 3 0 FUJITSU MAY2073RC 0103 70136MB

Select 2 or more disks for Volume Raid 1/E Raid 0

Figure 16 Emerson ATCA-S201 Hardware RAID (new installation screen-shot)

Disk An enumeration of disks that may be used in new RAID LUN definition. Parent Identifies the volume that claims ownership to a disk. ‘Unknown’ indicates no volume ownership. Host/Bus/Target/Lun Identifies the SCSI parameters used to address the virtual RAID device Vendor/Product/Rev Use these items to identify the physical disk resource. Size Capacity of the disk Select “Radio button” used to select which disks will participate in the new RAID LUN definition RAID1/E Click to create a new RAID1 LUN (mirroring) RAID0 Click to create a new RAID0 LUN (stripping)

Click to commit the selections and create the new RAID device.

Table 26 CLI command syntax, set_raid: Add RAID configuration Convention: atca_blade set_raid Y <diskmask> <RAID_level> Y +

Emerson ATCA-S201 — 5.1.1 JBOD mode diagram (page 69)
Fig. 30 · 5.1.1 JBOD mode

Ydisk|Ndisk … [Ydisk|Ndisk] variable length mask. Must specify one entry for each system disk. Ydisk includes disk in RAID volume, Ndisk exclude disk from RAID volume. 0|1 Use value 0 to apply RAID0, and value 1 to apply RAID1 atca_blade set_raid Y Ydisk Ydisk Ydisk Ndisk 1 Y + Syntax examples

System has four disks. Assign the first three disks to new RAID1 volume.

Show 5 more labels / short text on this page
‐ · Hardware RAID Configuration · Parameter Description · Create Volume · CLI command syntax
Page 70 of the Emerson ATCA-S201 user manual — 5.2.2 How new RAID definitions alter device menu display
Page 70 · click to enlarge
Page 70

5.2.1 Hardware RAID levels and capabilities

RAID Level RAID0 RAID1 RAID1E

Description Two or more disks are grouped to provide a capacity aggregation function. The advantage is the multiplicative performance and capacity effect of up to 10 spindles working in concert to store or retrieve data for the host.

Exactly two disks are grouped to provide a mirror function. By definition, two drives our bounded in a fashion such that every write to one drive is mirrored to the second. If a failure occurs with either drive, data is still accessible via the surviving drive.

Three or more disks are grouped to provide a mirror function using an algorithm extension to permit use with many drives. If a failure occurs with any drive, data is still accessible via the surviving drives.

S0 S1 S2 S3 S4

S0 S1 S2 S3 S4

S0 S1 S2 S3 S4

RAID1

RAID1E

RAID0

S0 S1 S2 S3 S4 S4

S0 S0’ S1 S1’ S2 S2’

S0 S0’ S1’ S2 S3 S3’

S1 S2’ S4

Disk 1 Disk 2

Disk 1 Disk 2

Disk 1 Disk 2

1. A maximum of 2 RAID volumes may be defined on each ATCA-S201.
2. A maximum of 2 global hot spares may be defined for each ATCA-S201.
3. A maximum of 10 disks may be used for a single RAID volume
4. A maximum of 12 disks (cumulative) for both RAID volumes (not including spares)

5.2.2 How new RAID definitions alter device menu display

The number of devices appearing in the Physical Disks menu will change once the user applies RAID services. The figure below illustrates this concept. In this example, there are four AMC disk modules available to the ATCA-S201, but only three disks appear in the physical disk menu.

Show 8 more labels / short text on this page
Data Layout Diagram · Data · Data · Data · Stripe Stripe Stripe · Stripe Stripe Stripe · Stripe Stripe Stripe · Disk 3
Page 71 of the Emerson ATCA-S201 user manual — Section 3
Page 71 · click to enlarge
Page 71
Emerson ATCA-S201 — 5.2.3 Modify existing RAID configurations diagram (page 71)
Fig. 31 · 5.2.3 Modify existing RAID configurations

Figure 17 Figure shows how RAID LUN definitions alter physical disk display

5.2.3 Modify existing RAID configurations

After creating a RAID volume, the RAID configuration tool page changes to include several new configuration options. The menu is now comprised of four sections, arranged to facilitate creation and deletion of RAID volumes and global hot spares.

Emerson ATCA-S201 — 5.2.3 Modify existing RAID configurations diagram (page 71)
Fig. 32 · 5.2.3 Modify existing RAID configurations

Disk Bus Target Lun Vendor Product Rev Size Select

Section 1

Select 2 or more disks for Volume Raid 1/E (Mirroring Extended) Raid 0 (Striping)

Volume Bus Target Type WWID State Status Size Stripe Size

Volume 0 0 6 Raid1 00ba23e977ca6eb7 optimal enabled 70008 0

Section 2

Member Physdisk Errors Bus Target Lun Vendor Product Rev Size State

0 56 0 FUJITSU MAY2073RC 0103 70136MB online

1 1 0 0 9 0 SEAGATE ST9146803SS 0002 140014MB online

Available Disk Bus Target Lun Vendor Product Rev Size Select

Section 3

Section 4

No Disks Have Been Allocated to Hot Spare Pools

Figure 18 Hardware RAID configuration screen showing existing RAID volume

Page 72 of the Emerson ATCA-S201 user manual — 5.2.3 Modify existing RAID configurations
Page 72 · click to enlarge
Page 72

Section 1 — Create RAID volumes

List of remaining disks available for new RAID volume definition. Click to select disk members. Click to select RAID level Click create Volume Upon completion, the physical disk view will change to display the new Virtual RAID volume while its disk members become hidden. Section 2 —RAID Status Summary

Provides a detailed status of existing RAID volumes, and details regarding the “hidden” disk members. Click “delete” to erase this volume and return all of the member disks to the pool of available disks. Section 3 — Allocate Hot Spare List of disks available for new global hot spare. The ATCA-S201 will use a global hot spare to repair a RAID1 or RAID1E volume that is degraded. Section 4- Hot spare status Provides a detailed status of existing global hot spares. Click “delete” to return a spare disk to the pool of available disks.

Understanding the Hardware RAID status table page

Once the RAID volume is created, the individual disks comprising a RAID disk are “hidden” from the OS and physical disk view, but are shown in the RAID status table.

Volume The ATCA blade is label string identifies the RAID volume. Bus/Target Identifies the SCSI parameters used to address the virtual RAID device Type Identifies the RAID level employed by the virtual RAID device. (Raid0, Raid1, or Raid1E) WWID The World-Wide Identification, is an eight byte SAS address that uniquely identifies the virtual RAID volume. Optimal — The RAID volume and all comprising disk members are fully operational Degraded - The RAID volume is accessible for read/write operation, but one of its underlying disk members is offline.

Failed - the RAID volume is not accessible for read/write operations. Data loss may have occurred. Enabled (default) — The RAID volume is able to receive I/O commands Status

Offline — The RAID volume cannot receive I/O Size The usable capacity, (MB) of the Virtual RAID drive. Stripe Size The maximum chunk of data that is written to one disk of a RAID group. The stripe width = Stripe size * number of disks. The ATCA- S201 currently applies a fixed size of 64 KB.

Show 4 more labels / short text on this page
Hardware RAID configuration · Description · Parameter Description · State
Page 73 of the Emerson ATCA-S201 user manual — 5.3.1 Software RAID web-configuration menu usage
Page 73 · click to enlarge
Page 73

5.3 Software RAID configuration

Administrators may use the ‘MD RAID’ menus to configure the Software AID features of ATCA-S201. The implementation leverages the mdadm tool available with the 2.6.23 Linux kernel, which also offers the ability to conduct all volume setup and configuration via a shell commands. Upon creation, a new software raid-device will appear as a new device in web or cli configuration menus. Users may utilize the new raid-device to create logical volumes, and configure iSCSI and NAS file shares. The ‘MD RAID’ configuration tool appears within the html tool’s main navigation panel on the left side as shown in the figure below.

5.3.1 Software RAID web-configuration menu usage

On a new system installation, this configuration menu enables the creation of RAID disk(s) that will appear in the physical disk menu. Once created, RAID disks are managed in the same manner as other physical disks, but boast benefits including improved performance and redundancy.

Emerson ATCA-S201 — 5.3.1 Software RAID web-configuration menu usage diagram (page 73)
Fig. 33 · 5.3.1 Software RAID web-configuration menu usage

iSCSI nfs smb Shares LVM2 MD RAID Configuration Hardware RAID Physical Disks Maintenance

Disk Parent Bus Target Lun Vendor Product Rev Size Select

/dev/sda Unknown 0 1 0 HITACHI HUC101414CSS300 A410 140205MB

/dev/sdb Unknown 0 2 0 HITACHI HUC101414CSS300 A410 140205MB

/dev/sdc Unknown 0 0 0 HITACHI HUC101414CSS300 A410 140205MB

Add to Volume RAID 0 RAID1 RAID 4 RAID 5 RAID 6 Override warnings

Figure 19 Emerson ATCA-S201 MD RAID (new installation screen-shot)

Available Disk An enumeration of disks that may be used in new RAID LUN definition. Parent Identifies the volume that claims ownership to a disk. ‘Unknown’ indicates disk has no known volume ownership. Bus/Target/Lun Identifies the SCSI parameters used to address the virtual RAID device Vendor/Product/Rev Use these items to identify the physical disk resource.

Select ‘Radio button’ identifies which disks will participate in the new RAID LUN definition.

Add to volume ‘Radio button’ adds the selected disk(s) to an existing volume as spare disk(s). If a volume is degraded, the volume will immediately commence a re-build operation.

RAID0 Click to create a new RAID0 LUN (stripping)

RAID1 Click to create a new RAID1 LUN (mirroring)

RAID4 Click to create a new RAID4 LUN (Fixed parity)

RAID5 Click to create a new RAID5 LUN (Rotating parity)

RAID6 Click to create a new RAID6 LUN (double parity)

Show 12 more labels / short text on this page
‐ · Emerson ATCA-S201 · + · + · + · + · + · ‐ · + · + · + · Parameter Description
Page 74 of the Emerson ATCA-S201 user manual — 5.3.2 Software RAID, CLI command syntax
Page 74 · click to enlarge
Page 74

ˇ Use this drop down menu to choose a volume name. Four choices: md0, md1,md2 or md3

Click to commit the selections and create the new RAID device.

Ignore Warnings ‘Radio button’ will ignore minor mdadm warnings. Example ignore warning when creating RAID1 with disks that have greater than 1% capacity difference. This Filed self-clears on each use.

Import Foreign Array Will display ONLY in situations when a drive contains meta-data that indicates it was at one time a member of a software RAID volume. Click and select participating drives to attempt an import of the volume.

Clear ownership Will display ONLY in situations when a drive contains meta-data that indicates it was at one time a member of a software RAID volume. Click and select drives to clear all meta-data stored on these disk(s). This operation will permanently eliminate the import array option.

5. A maximum of 4 software-RAID volumes may be defined on each ATCA-S201 .
6. The default stripe size is 64KB, but can be changed by creating the array using the CLI mdadm tool instead.
7. A user may assign multiple spare disks to each volume.

5.3.2 Software RAID, CLI command syntax

Table 27 CLI command syntax, mdadm: manage RAID configuration

Create new volume mdadm –-create raiddevice –n <#devices> -l <raidlevel> [-c <stripe_size>] <component-devices> --create “Create” mode, used initialize a new md array, associate some devices with it, and activate the array. Raiddevice Device name assigned to new volume. Example /dev/md0. Integer, specifies the number of Integer: 4=raid4, 5=raid5, 6=raid6 Optional, will default to 64 if omitted, expressed in kilobytes. Within a stripe, this defines the ‘chunk’ of data read or written to any single member disk. Space delimited list of component devices. Example /dev/sda /dev/sdb…

mdadm --detail --scan > /etc/mdadm.conf

Preserve new volume attributes

Issue this command immediately after creating a new volume. This command preserves key volume parameters, and ensures the new volume is available across system reboots.

List volume status mdadm --detail --scan

Issue this command at any time to inspect volume status

Create hot spare mdadm –-add raiddevice <spare-device>

--add Used to add a spare disk to an existing raid-device. Users may issue this commend any number of times to specify multiple spare drives if available. Raiddevice Device name assigned to existing volume. Example /dev/md0 Designate spare device. Example /dev/sda

Remove faulty disk mdadm –-remove raiddevice <faulty-device>

md0 · Submit

Page 75 of the Emerson ATCA-S201 user manual — 5.3.2 Software RAID, CLI command syntax
Page 75 · click to enlarge
Page 75

--remove Used to remove a disk from a volume definition. Users may later re-add the disk using the —add command. Raiddevice Device name assigned to existing volume. Example /dev/md0 Designate faulty device. Example /dev/sda

Remove volume /etc/rc.d/init.d/mdarray stop

step2 Edit file/etc/ mdadm.co nf and remove RAID volume entry
Page 76 of the Emerson ATCA-S201 user manual — S4
Page 76 · click to enlarge
Page 76

5.3.3 Software RAID levels and capabilities

RAID Level Description Data Layout Diagram

RAID4 Three or more disks are grouped in fashion where all written data is available even when any single disk drive is removed or fails. RAID4 employs block level striping with a dedicated parity disk.

S0 S1 S2 S3 S4

RAID4

S0 S1 S2 S3 S4 S4

Disk 1 Disk 2

RAID5 Three or more disks are grouped in fashion where all written data is available even when any single disk drive is removed or fails. RAID5 employs block level striping with a distributed parity disk. This provides a significant advantage for RAID5 vs RAID4 for write operations, because the bandwidth of all disks is available for parity write operations.

S0 S1 S2 S3 S4

RAID5

S0 S1 S2 Parity Parity S4

S3 S5

RAID6 Four or more disks are grouped in fashion where all written data is available even when any two disk drives are removed or fail. RAID6 employs block level striping with two distributed parity disks. While RAID6 provides a significant redundancy advantage, each write spawns two additional parity calculations, which in turn adds commensurate loads on both the internal CPU and memory systems.

Disk 1 Disk 2

S0 S1 S2 S3 S4

RAID6

S0 S1 S2 Parity-P Parity-P Parity-Q

S3 S5 Parity-Q S6 S7 Parity-P

S4

Disk 1 Disk 2

Show 16 more labels / short text on this page
Data · Stripe Stripe Stripe · Parity · Parity Parity · Disk 3 · Data · Stripe Stripe Stripe · Parity · Disk 3 · Data · Stripe Stripe Stripe · Parity-P Parity-Q · Parity-Q · Stripe · Disk 3 · Disk 4
Page 77 of the Emerson ATCA-S201 user manual — 6.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)
Page 77 · click to enlarge
Page 77

6 Prepare Logical Volumes for iSCSI or file sharing

Configuration Step:

Ethernet Comm. Setup

NFS / SMB Share Setup

This chapter explains how to prepare a device resource (example /dev/sda) for iSCSI or NAS file sharing. Disks appearing in the “physical disk” menu must first be mapped to a Logical Volume group before it can be used for these services. Once a device is committed as a shared resource for iSCSI or NAS for service, it becomes un-available for new RAID or logical volume definitions unless it is first un-shared.

SiteB1

HW RAID

SiteB2

IP host 1:1 mapping (JBOD)

SiteB3
SiteB4

1:1 mapping (JBOD)

6.1 Benefits of a logical Volume Group (/dev/vga)

A volume group is a group of one or more physical disks. A volume group gives the administrator several powerful tools to manage storage resources. These features include:

Define volume groups with multiple disks or partitions Dynamically increase a volume group by adding new physical disks

6.1.1 Benefits of a Logical device/disk (/dev/vga/lva0)

A volume group may be divided into multiple pieces. Each piece is known as logical device but may also be called a logical disk or volume. A Logical Device offers powerful features that include:

Essentially unlimited logical devices defined on each volume group Dynamically increase the size of logical device

Show 25 more labels / short text on this page
RS232 Console Setup · RAID LUN Setup · Logical Volume · iSCSI Device Setup · Setup · AMC disk · Physical · Logical groups · iSCSI & NAS · modules · disks · & volumes · iSCSI · LUNs · sda · vga · Zone-2 Fabric · IP network · Zone-2 Base · sdb · NFS share points · Zone-3 RTM · vgz · sdc · CIFS share points
Page 78 of the Emerson ATCA-S201 user manual — 6.2.1 Interpreting physical disk status
Page 78 · click to enlarge
Page 78

6.2 Viewing Physical disks

Logical volumes are comprised of one or more physical disk members. Using the HTML configuration tool, the user may view the available set of physical disks.

Emerson ATCA-S201 Physical Disks

This top html menu provides a summary list of current physical disks.

StorBlade99 ATCA-S201 Physical Disk Summary

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks /dev/sda /dev/sdb /dev/sdc Maintenance

Device Name Parent Device State Vendor Model Rev

/dev/sda Unknown Offline HITACHI HUC101414CSS300 A410

/dev/sdb Unknown Offline FUJITSU MAY2073RC 0103

/dev/sdc Unknown Offline LSILOGIC Logical Volume 3000

Update Java Menu to reflect added disks

Figure 20 HTML tool, Emerson ATCA-S201 Physical Disk (summary screen)

6.2.1 Interpreting physical disk status

Physical disks resources can be mapped to logical volume groups, which are split into Logical device ‘slices’ which are then shared as iSCSI or NAS. The number of Physical disks may not necessarily correlate 1:1 with the hardware disk pool (e.g. number of AMC drive carriers), because physical disks may include volumes created through RAID services that mask the individual hardware disk members. From the ATCA-S201 perspective, physical disks are presented as Linux SCSI devices (/dev/sd[a-z]).

Online Device is actively used as either a iSCSI export or NAS share volume

Offline Device is available for iSCSI or NAS operations.

Show 13 more labels / short text on this page
‐ · Emerson ATCA-S201 · + · + · + · + · + · + · + · ‐ · Re‐Draw Tree · + · Status description
Page 79 of the Emerson ATCA-S201 user manual — 6.2.2 View physical disk properties
Page 79 · click to enlarge
Page 79

6.2.1.1 Disk view refresh, Re-draw Tree button

The physical disk assignments change as disks become utilized in a RAID definitions. Use the “Re-Draw Tree” button to rescan for physical disks, and refresh the menu view.

6.2.1.2 Rescan SAS Topology

If the disk configuration is not displaying properly, users can rescan the SAS topology, using the button located on the Maintenance menu page.

6.2.1.3 Software Reset SAS Controller

If the disk configuration is not displaying properly, users can issue a software-reset signal to the embedded SAS controller using the button located on the Maintenance menu page. If users have hot-swapped many disks, this ensures the SAS controller has completely purged internal tables, and is properly presenting the new or remaining disks to the operating system.

Software reset SAS controller

6.2.2 View physical disk properties

Additional property informational is available for each physical disk. These may be viewed by clicking the individual device (e.g. /dev/sda), which opens the menu shown below.

Emerson ATCA-S201 — 6.2.2 View physical disk properties diagram (page 79)
Fig. 34 · 6.2.2 View physical disk properties
Emerson ATCA-S201 — 6.2.2 View physical disk properties diagram (page 79)
Fig. 35 · 6.2.2 View physical disk properties

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks /dev/sda /dev/sdb /dev/sdc Maintenance

Emerson ATCA-S201 — 6.2.2 View physical disk properties diagram (page 79)
Fig. 36 · 6.2.2 View physical disk properties

Name State Type Parent Host Bus Target LUN Vendor Model Rev

/dev/sda Online Raw Unknown 0 0 19 0 ATA 64G SATA Flash D 401A

Re‐Draw Tree · Rescan SAS topology

Page 80 of the Emerson ATCA-S201 user manual — 6.3 Create a logical Volume Group (/dev/vga)
Page 80 · click to enlarge
Page 80

Table 21 HTML tool, Emerson ATCA-S201 Physical Disk (configuration screen)

Device Name Linux SCSI device name, from ATCA-S201 management perspective Online: indicates the device is active and ready for I/O State

OfflineRaw: indicates the device was not formatted by the ATCA-S201 Type

file: indicates the device was formatted by the ATCA-S201 Parent Identifies the volume that claims ownership to a disk. ‘Unknown’ indicates disk has no known volume ownership. Host/Bus/Target/LUN Identifies the SCSI parameters used to address the physical device Vendor/model/Rev Identifies the vendor and revision of the disk device. If vendor = LSILogic, this physical device is a RAID volume managed by the ATCA- S201 resources.

6.3 Create a logical Volume Group (/dev/vga)

A volume group must contain at least one physical disk member. The figure below outlines the steps that will be taken to create volume groups and logical device/disk volumes.

Emerson ATCA-S201 — 6.3 Create a logical Volume Group (/dev/vga) diagram (page 80)
Fig. 37 · 6.3 Create a logical Volume Group (/dev/vga)

Shares LVM2 LVM2 Configuration MD RAID Configuration Hardware RAID Configuration Physical Disks /dev/sda /dev/sdb /dev/sdc /dev/sdd /dev/sde /dev/sdf /dev/sdg Maintenance

Figure 22 HTML tool, Main navigation side-bar, LVM2->Configuration

Logical volumes are comprised of one or more physical disk members. Using the HTML configuration tool, the user may view the available set of physical disks and assign them to volume groups.

Emerson ATCA-S201 LVM2 LVM2 Configuration

The screen shows physical disks which are available for a new volume group definition.

Parameter Description

Page 81 of the Emerson ATCA-S201 user manual — ˇ
Page 81 · click to enlarge
Page 81
Emerson ATCA-S201 — Create a logical Volume Group (/dev/vga) diagram (page 81)
Fig. 38 · Create a logical Volume Group (/dev/vga)

iSCSI nfs smb Shares LVM2 LVM2 Configuration MD RAID Hardware RAID Physical Disks Maintenance

StorBlade99 ATCA-S201 Available Physical Disks

Group State Capacity File Type Vendor Model Rev Select

/dev/sda ‐none‐ Offline 140205(MBytes) Raw Unknown HITACHI HUC101414CSS300 A410

/dev/sdb ‐none‐ Offline 70136(MBytes) Raw Unknown FUJITSU MAY2073RC 0103

/dev/sdc ‐none‐ Offline 70008(MBytes) Raw Unknown LSILOGIC Logical Volume 3000

ˇ

Select 1 or more disks for Volume Group

Figure 23 HTML tool, Emerson ATCA-S201 LVM2 Configuration

Follow these instructions to create a new volume group

2. Click the ‘Select’ box to choose which disks will be assigned to the new volume

group.

3. Use drop down menu to specify volume group name. (vga,vgb, etc)
4. Click the ‘Submit’ button
Show 14 more labels / short text on this page
‐ · Emerson ATCA-S201 · + · + · + · + · ‐ · + · + · + · + · Disk Name Volume · vga · Submit
Page 82 of the Emerson ATCA-S201 user manual — Create a logical Volume Group (/dev/vga)
Page 82 · click to enlarge
Page 82

Table 28 CLI command syntax, create new volume groups Convention: atca_blade set_lvm2 Y Y Y + Ydisk |Ndisk … [Ydisk|Ndisk] variable length mask. Must specify one entry for each available system disk. Ydisk includes disk in new volume group, Ndisk exclude disk from new volume group. atca_blade set_lvm2 Y Ydisk Ndisk Y Y + Syntax examples

System has two disks. Assign the first disk to a new volume group.

Table 24 HTML tool, Emerson ATCA-S201 LVM2 logical group (status screen)

Volume/member Linux SCSI device name, from ATCA-S201 management perspective Access Displays the volumes access privilege settings; default is read/write Total Size The calculated capacity (GB) is the product of ‘Total PE’ x ‘PE Size’. PE Size The physical extent (PE) in LVM is the block-size that physical volumes are using. The default physical extent is 4MB. Total PE This is the summation of physical extents contributed by its members. Allocated Space/PE The number of physical extents committed to logical device definitions. Free Space/PE The number of physical extents not yet committed (available) to new or existing logical devices.

CLI command syntax · Parameter Description

Page 83 of the Emerson ATCA-S201 user manual — 6.4.1 Extend/Expand a Logical Device (/dev/vga/lva0)
Page 83 · click to enlarge
Page 83

6.4 Creating a Logical Device (/dev/vga/lva0)

After successfully creating a volume group, the user must next create a logical device which can be assigned to iSCSI or NAS services. The LMV2 configuration menu will update to show the new volume group as shown below.

StorBlade99 ATCA-S201 Available Physical Disks

Group State Capacity File Type Vendor Model Rev Select

/dev/sda ‐none‐ Offline 140205(MBytes) Raw Unknown HITACHI HUC101414CSS300 A410

/dev/sdb ‐none‐ Offline 70136(MBytes) Raw Unknown FUJITSU MAY2073RC 0103

Select 1 or more disks for Volume Group

ˇ Volume Group vga Status

Volume Access Total Size PE Size Total PEs Allocated Space Free Space Resizable

vga read/write 68(GBytes) 4(MBytes) 17501 0(GBytes) 68(GBytes) resizable

Member PV Name Capacity PE Size Total PE Allocated PE Free PE Status

1 /dev/sdc 68(GBytes) 4(MBytes) 17501 0 17501

Volume LV Name Access Status Open Size Select

Enter size to create or extend GBytes 68

Follow these instructions to create a new logical device

1. Enter the size of the new device in the field labeled

Enter size to create or extend [ ]. (It can exceed the seed value displayed in the box).

2. Click the ‘New Volume’ button

Table 29 CLI command syntax, create new logical device Convention: atca_blade set_lvm2 index <diskmask> Y <size> Y +

Ndisk … [Ndisk] variable length mask. Must specify one entry for each available system disk. Size of new logical volume. atca_blade set_lvm2 Y Ndisk Ndisk Y 100 Y + Syntax examples

Create a logical disk of size 100GB.

6.4.1 Extend/Expand a Logical Device (/dev/vga/lva0)

The user may dynamically expand the space allocated to a logical device.

Follow these instructions to extend an existing volume group

1. Click the ‘Select’ box to choose which device that will get additional

capacity.

Show 8 more labels / short text on this page
Disk Name Volume · vga · Submit · Logical Devices · New Volume · Extend Volume · Delete Volume · CLI command syntax
Page 84 of the Emerson ATCA-S201 user manual — 6.4.2 Delete a Logical device (/dev/vga/lva0)
Page 84 · click to enlarge
Page 84
2. Enter the new size increase in the field labeled

Enter size to create or extend [ ]. (It can exceed the seed value displayed in the box).

3. Click the ‘Extend Volume’ button

6.4.2 Delete a Logical device (/dev/vga/lva0)

The user may dynamically delete a logical device, and return all the space to the volume group.

Follow these instructions to extend an existing volume group

1. Click the ‘Select’ box to choose which device will be deleted.
2. Click the ‘Delete Volume’ button
Page 85 of the Emerson ATCA-S201 user manual — 6.5.1 Commit a logical drive for iSCSI service
Page 85 · click to enlarge
Page 85

6.5 Manage shares (prepare logical device for service)

By default, all logical devices are unformatted and not yet visible to either iSCSI or NAS services. The manage share menu is used to prepare a logical device for one or more of these services (iSCSI, NFS or SMB). The manage share will display a menu for each logical device defined, along with options to make service assignments.

Emerson ATCA-S201 — 6.5 Manage shares (prepare logical device for service) diagram (page 85)
Fig. 39 · 6.5 Manage shares (prepare logical device for servic…

iSCSI nfs smb Shares Manage Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

StorBlade99 ATCA-S201 Shared Resource /dev/vga/lva0

Logical Volume Share Name Share Type Block / File Action

/dev/vga/lva0 iSCSI nfs smb

Figure 25 HTML tool, Manage shares menu function

Block File field Description

This button is available for logical devices not yet designated as either iSCSI or NAS. Formatting a physical disk will permanently erase all existing data.

If the Share type field is nfs or smb, this button commits the logical device and enables a “file share mount point”. If the Share type field iSCSI this button is commits the logical device and enables an “iSCSI mount point”. Block Indicates the bytes on the logical device are not managed by the ATCA-S201. If exposed by iSCSI, an external host owns the device in its entirety (partitioning, formatting etc.). File Indicates the logical device is formatted, and the bytes on the device are managed by the ATCA-S201 and its Linux file system including partitioning and formatting.

6.5.1 Commit a logical drive for iSCSI service

A newly defined logical drive is immediately ready for iSCSI block sharing. In the example above, the logical disk named /dev/vga/lva0 is ready for “iSCSI share”.

Show 16 more labels / short text on this page
‐ · Emerson ATCA-S201 · + · + · + · ‐ · + · + · + · + · + · lva0 · Format · Share · Format · Share
Page 86 of the Emerson ATCA-S201 user manual — 6.5.2 Commit a logical drive for NAS service
Page 86 · click to enlarge
Page 86

Follow these instructions to assign iSCSI service

1. Enter a ‘human friendly’ name for your new iSCSI share in the field labeled

Share Name [ ].

2. Click the ‘iSCSI box.
3. Click the ‘Share’ button.

Upon completion the ‘Block / File’ field will display Block.

Table 30 CLI command syntax, create iSCSI share Convention: atca_blade manage_shares Y <diskmask> N Y <name> Y Y +

Y |N … [Y|N] variable length mask. Must specify one entry for each system disk. Use to ‘Y’ designate which disk to share. Use ‘N’ in all other positions. < name> Enter human friendly “share name” atca_blade set_shares Y Y N N Y iSCSI_targetAA Y Y + Syntax example

#1 Designate disk 1 of 2, an iSCSI share called iSCSI_target_AA atca_blade set_shares Y N Y N Y iSCSI_targetBB Y Y + Syntax example

#2 Designate disk 2 of 2, an iSCSI share called iSCSI_target_BB

6.5.2 Commit a logical drive for NAS service

Before a disk may be utilized for file sharing services (nfs/smb), it must be formatted. Depending on the size of the device or virtual volume, formatting may take several minutes.

Follow these instructions to assign NAS service

1. Enter a ‘human friendly’ name for your new NAS share in the field labeled

Share Name [ ].

2. Click the ‘Format’ button to commit a logical device as NFS/SMB share.

Formatting can take several minutes, with duration depending on the size.

3. Click the ‘nfs’ box to allow access via OS’s that support network file services,

such as Linux or Solaris®.

4. Click the ‘smb’ box to allow access via OS’s that support Server Message

Block services, such Microsoft® Windows®.

5. Click the ‘Share’ button

Upon completion the ‘Block / File’ field will display File.

CLI command syntax

Page 87 of the Emerson ATCA-S201 user manual — 6.5.3 Un-commit an iSCSI share
Page 87 · click to enlarge
Page 87

Upon completing these steps, the Mange share menu will update as shown below. Changes may be applied by clicking the appropriate box and clicking ‘Update’.

Table 31 CLI command syntax, format a logical volume Convention: atca_blade set_shares Y <diskmask> Y Y +

Use to ‘Y’ designate which disk to format. Use skip in all other positions. atca_blade set_shares Y skip Y Y Y + Syntax example

#1 Designate disk ‘lva’ an iSCSI share called iSCSI_target_AA atca_blade set_shares Y N Y N Y iSCSI_targetBB Y Y + Syntax example

#2 Designate disk 2 of 2, an iSCSI share called iSCSI_target_BB

6.5.3 Un-commit an iSCSI share

The administrator may modify or un-share any currently shared logical device by navigating to the html configuration screen:

Emerson ATCA-S201 Shares Manage Shares The Manage shares menu displays the active status of all logical devices. Scroll to the device of interest, and complete the steps below.

Emerson ATCA-S201 — 6.5.3 Un-commit an iSCSI share diagram (page 87)
Fig. 40 · 6.5.3 Un-commit an iSCSI share

iSCSI nfs smb Shares Manage Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

Show 12 more labels / short text on this page
CLI command syntax · ‐ · Emerson ATCA-S201 · + · + · + · ‐ · + · + · + · + · +
Page 88 of the Emerson ATCA-S201 user manual — 6.5.4 Un-commit an NFS/SMB share
Page 88 · click to enlarge
Page 88

StorBlade99 ATCA-S201 Shared Resource /dev/vga/lva0

Logical Volume Share Name Share Type Block / File Action

/dev/vga/lva0 lva0 iSCSI nfs smb Block ‐In Use ‐

Share Name Mount Point <‐> Fullname Share Type Delete Action

lva0 /mnt/shr/block/lva0 <-> /mnt/shr/block/lva0 iSCSI nfs smb

Follow these instructions to un-commit a logical drive

1. Un-Click all the ‘iSCSI’ box
2. Click the ‘Update’ button.
3. Click the ‘Delete’ button.
4. Click the ‘Update’ button.

Later, the logical device may be reassigned to a new share, or the space returned to the Volume group be deleting the device using the LVM2 configuration menu.

6.5.4 Un-commit an NFS/SMB share

The administrator may modify or un-share any currently shared logical device by navigating to the html configuration screen:

Emerson ATCA-S201 Shares Manage Shares The Manage shares menu displays the active status of all logical devices. Scroll to the device of interest, and complete the steps below.

Emerson ATCA-S201 — 6.5.4 Un-commit an NFS/SMB share diagram (page 88)
Fig. 41 · 6.5.4 Un-commit an NFS/SMB share

iSCSI nfs smb Shares Manage Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

Show 12 more labels / short text on this page
Update · ‐ · Emerson ATCA-S201 · + · + · + · ‐ · + · + · + · + · +
Page 89 of the Emerson ATCA-S201 user manual — 6.6 Re-name iSCSI shares, make more ‘human-friendly’
Page 89 · click to enlarge
Page 89

StorBlade99 ATCA-S201 Shared Resource /dev/vga/lva0

Logical Volume Share Name Share Type Block / File Action

/dev/vga/lva0 lva0 iSCSI nfs smb Block ‐In Use ‐

Share Name Mount Point <‐> Fullname Share Type Delete Action

lva0 /mnt/shr/block/lva0 <-> /mnt/shr/block/lva0 iSCSI nfs smb

Follow these instructions to un-commit a logical drive

1. Un-Click the ‘nfs’ and ‘smb’ box
2. Click the ‘Update’ button.
3. Click the ‘Delete’ button.
4. Click the ‘Update’ button.

Later, the logical device may be reassigned to a new share, or the space returned to the Volume group be deleting the device using the LVM2 configuration menu.

6.6 Re-name iSCSI shares, make more ‘human-friendly’

As a default, the ATCA will name shares based on the underlying device path. Though these is nothing wrong with this, the user may use the ‘manage shares’ menu to assign more appropriate names.

Update

Page 90 of the Emerson ATCA-S201 user manual — 7.1.1 Add or create an iSCSI target
Page 90 · click to enlarge
Page 90

7 iSCSI device setup tools

Configuration Step:

Ethernet Comm. Setup

NFS / SMB Share Setup

This chapter explains how to create one or more iSCSI LUNs for external host access. The user must complete step 4 before this step can be accomplished.

SiteB1

HW RAID

SiteB2

IP host 1:1 mapping (JBOD)

SiteB3
SiteB4

1:1 mapping (JBOD)

7.1 iSCSI configuration menu

Using the HTML configuration tool, navigate to this configuration page .

Emerson ATCA-S201 iSCSI iSCSI Configuration

This top html menu provides the ability to create an iSCSI target on a device (e.g. /dev/vga/lva0) that was previously committed for iSCSI block I/O share (see chapter ).

7.1.1 Add or create an iSCSI target

These are the final steps to make an iSCSI device ‘appear’ on the IP network.

Show 25 more labels / short text on this page
RS232 Console Setup · RAID LUN Setup · Logical Volume · iSCSI Device Setup · Setup · AMC disk · Physical · Logical groups · iSCSI & NAS · modules · disks · & volumes · iSCSI · LUNs · sda · vga · Zone-2 Fabric · IP network · NFS share points · Zone-2 Base · sdb · vgz · Zone-3 RTM · sdc · CIFS share points
Page 91 of the Emerson ATCA-S201 user manual — 7.1.2 Add or create an iSCSI LUN
Page 91 · click to enlarge
Page 91
Emerson ATCA-S201 — Add or create an iSCSI LUN diagram (page 91)
Fig. 42 · Add or create an iSCSI LUN

iSCSI iSCSI Configuration nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

StorBlade99 ATCA-S201 iSCSI Configuration Global Settings

iSNSServer None iSNSAccessControl No

Add an iSCSI Target

Figure 26 HTML tool, Emerson ATCA-S201 iSCSI iSCSI Configuration

Follow these instructions to create a new iSCSI target

1. Click the ‘add an iSCSI Target’ button.

After confirming the popup, the iSCSI configuration tool page changes, and will display a list of operating attributes for the new iSCSI target. The menu will also include a new section to create an iSCSI LUN (see next section).

7.1.2 Add or create an iSCSI LUN

The final step in defining a usable iSCSI resource requires the creation of one or more iSCSI LUNs. A LUN (Logical Unit Number) is an addressable entity on the iSCSI target. A target may have several LUNs, and each LUN maps one-to-one with a logical share device. When an external host subsequently connects to the iSCSI target, it may write to a LUN, which again is mapped to the logical device. An external host may partition and format each LUN individually and write independent data.

Table 32 CLI command syntax, create iSCSI share Convention: atca_blade set_iscsi

This command invokes an interactive session to modify the iSCSI setting of the blade. The command will spawn a series of Yes/No questions which guide the user the iSCSI configuration options. The command session and responses can be scripted to automate a common configuration setup on multiple blades.

Show 13 more labels / short text on this page
Emerson ATCA-S201 · ‐ · ‐ · + · + · + · Submit Changes · + · + · + · + · + · CLI command syntax
Page 92 of the Emerson ATCA-S201 user manual — ˇ
Page 92 · click to enlarge
Page 92

Target iqn.1995-07.com.emerson:ATCA-S201.Target0

Delete This iSCSI Target

Alias NoAlias MaxConnections 1

InitialR2T No ImmediateData Yes

MaxRecvDataSegmentLength 262144 MaxXmitDataSegmentLength 262144

MaxBurstLength 262144 FirstBurstLength 65536

DefaultTime2Wait 2 DefaultTime2Retain 20

MaxOutstandingR2T 8 DataPDUInOrder 1

DataSequenceInOrder 1 ErrorRecoveryLevel 0

HeaderDigest None DataDigest None

Wthreads 8 IET tid 1

IncomingUser[0] OutgoingUser[0]

0 LUNs Served By This Target

LUN Path Type Remove

Add a new LUN Share to This Target

LUN Path Type Action

ˇ

ˇ

1 LUNs Served By This Target

LUN Path Type Remove

0 /export/iSCSI/lva0 blockio Remove

Add a new LUN Share to This Target

LUN Path Type Action

blockio No paths available 1

ˇ

ˇ Fol low these instructions to create an iSCSI LUN

2. Use the LUN Drop down menu, to specify the LUN assignment for the

resource.

3. Use the Path Drop down menu, to specify the logical device that will map to

this LUN.

4. Click the ‘Add LUN button. Repeat to add additional LUNs.

Add Lun 0 · lva0 · blockio

Page 93 of the Emerson ATCA-S201 user manual — 7.1.4 Delete an iSCSI Target (and all LUNS)
Page 93 · click to enlarge
Page 93

1 LUNs Served By This Target

LUN Path Type Remove

0 /export/iSCSI/lva0 blockio Remove

Add a new LUN Share to This Target

LUN Path Type Action

blockio No paths available 1

ˇ

ˇ

Figure 27 SCSI configuration screen updates to show the new LUN.

7.1.3 Remove an individual iSCSI LUN

The user can remove an iSCSI LUN from operation by opening the iSCSI configuration page, and clicking the “remove” box for the LUN, followed by the ‘submit changes’ button at the top of the screen. The data on the LUN is not erased, and remains intact but inaccessible on the target. When complete, the device resource can subsequently be re-assigned as a LUN in another iSCSI target, and data access is restored.

Follow these instructions to delete an iSCSI LUN

1. Click the ‘Remove button corresponding to the LUN you will remove.
2. Click the ‘Submit Changes’ button at the top of the menu.

7.1.4 Delete an iSCSI Target (and all LUNS)

The user can remove an iSCSI target (and all LUN assignments) from operation by opening the iSCSI configuration page, and clicking the “Delete This iSCSI Target” button. Clicking this button will generate a pop-up which will ask the user to confirm this operation.

Follow these instructions to delete an iSCSI Target

1. Click the ‘Delete Tthis iSCSI Target’ button corresponding to the Target you

will remove.

2. Click the ‘Submit Changes’ button at the top of the menu.
Page 94 of the Emerson ATCA-S201 user manual — 7.1.5 Advanced iSCSI configuration (expert mode)
Page 94 · click to enlarge
Page 94

7.1.5 Advanced iSCSI configuration (expert mode)

The iSCSI service running on the storage blade supports numerous configuration options that appear in the iSCSI section of web interface tool. Users may modify any number of parameters listed, and then click the ‘submit’ button located at the top of the page.

Alternatively, iSCSI configuration options may be set via simple edits to a text based configuration file /etc/ietd.conf using a console window. The configuration file contains an entry for each target entry created by the web or cli tools. The file contains a stanza style entry for each iSCSI target that begins with the parameter name: “Target”. The file syntax is explained in the next section. File changes become active at next reboot or by re-starting the iSCSI service (as root): /etc/rc.d/init.d/iscsi stop /etc/rc.d/init.d/iscsi start

Sample ietd.conf file for iSCSI targets

Everything before the first Target definition belongs to the global configuration. # iSCSI target configuration file ietd.conf # Target iqn.1995-07.com.emerson:BladeHost.Target0 IncomingUser OutgoingUser NoAlias Alias NoAlias #MaxConnections 1 No InitialR2T No ImmediateData Yes MaxRecvDataSegmentLength 262144 MaxXmitDataSegmentLength 262144 #MaxBurstLength 262144 #FirstBurstLength 65536 #DefaultTime2Wait 2 #DefaultTime2Retain 20 #MaxOutstandingR2T 8 #DataPDUInOrder 1 #DataSequenceInOrder 1

Target Default Settings

Page 95 of the Emerson ATCA-S201 user manual — 7.1.5 Advanced iSCSI configuration (expert mode)
Page 95 · click to enlarge
Page 95

#ErrorRecoveryLevel 0 #HeaderDigest None #DataDigest None #Wthreads 8 Lun 0 Path=/export/iSCSI/lva0,Type=blockio,ScsiId=RXEUlYcCN9siiOnP

Page 96 of the Emerson ATCA-S201 user manual — 7.1.5 Advanced iSCSI configuration (expert mode)
Page 96 · click to enlarge
Page 96

Table 33 iSCSI Advanced configuration and parameter definitions Target iqn.<yyyy-mm>.<tld.domain.host.Target#>[:<identifier>] Identifies the iSCSI Qualified Name, which is globally unique as required by the iSCSI standard. iqn. followed by a single dot “.” is the date (year and month) at which the domain is valid followed by a single dot “.” Reversed domain name followed by a single dot “.” Host name is assigned on Maintenance->Network page, followed by a dot “.” is set to numerically enumerate each iSCSI target definition. (e.g. Target0, Target1 etc)

The optional - permitted by RFC3720, but is not used IncomingUser <username> <password> Used to set the and to authenticate iSCSI initiators during discovery sessions, using CHAP. Several entries can be specified for each target discovery. If no IncomingUser is specified, any initiator may open a discovery session. Note: RFC 3720 requires to be 12 characters long. This is enforced by Microsoft’s® Initiator. OutgoingUser <username> <password> Used to set the and to authenticate the target to initiators during discovery sessions using CHAP. Only one outgoing / combination may be specified. Note: RFC 3720 requires to be 12 characters long. This is enforced by Microsoft’s® Initiator. Alias <string> May be set to a “friendly” human-readable name or description that is communicated to the initiator at Login. An initiator may elect to display this value when listing connected targets. NOTE: As an additional feature, this string is appended to the target name. MaxConnections Default 1 Sets the maximum number of connections an initiator may make with a each iSCSI target entity. 1 is the only valid value InitialR2T "No" — default: Indicates the initiator may include BurstLength bytes together immediately following an iSCSI command. This setting may reduce protocol handshakes, and thus improve system performance. "Yes" — Indicates the initiator has to wait for the target to solicit SCSI data before sending it. ImmediateData "Yes" — default: Indicates the initiator may combine iSCSI command and data information and send in the same packet. This setting may reduce protocol handshakes, and thus improve system performance. "No" — Indicates the initiator may not combine command and data information in the same packet. MaxRecvDataSegmentLength Default: 262144, sets the maximum data segment length that the target can receive. Note: The should be set to multiples of PAGE_SIZE. The maximum supported value is 64 * 4096 = 262144. MaxXmitDataSegmentLength Default: 262144, sets the maximum data segment length that the target can send. Note: The actual value is reduced to match the MaxXmitDataSegmentLength and the MaxRecvDataSegmentLength negotiated with each initiator during login. The should be set to multiples of PAGE_SIZE. The maximum supported value is 64 * 4096 = 262144. #MaxBurstLength Default: 262144, Sets the maximum amount of data the initiator may send in a single burst.

Page 97 of the Emerson ATCA-S201 user manual — 7.1.5 Advanced iSCSI configuration (expert mode)
Page 97 · click to enlarge
Page 97

Note: The should be set to multiples of PAGE_SIZE. The maximum supported value is 16 * 4096 = 65536. #DefaultTime2Wait Not currently supported #DefaultTime2Retain Not currently supported #MaxOutstandingR2T Default: 1, Controls the maximum number of data transfers the target may request at once, each of up to MaxBurstLength bytes. #DataPDUInOrder "Yes" — default:, Indicates the initiator MUST send data PDUs within sequences have to be at continuously increasing addresses. “No” — Not supported. #DataSequenceInOrder "Yes" — default: Indicates the initiator MUST send Data Sequences with continuous non-decreasing sequence offsets (R2T buffer offset for writes, or the smallest SCSI Data-In buffer offset within a read data sequence). “No” — Not supported. #ErrorRecoveryLevel 0 Default 0, Establishes the recovery level supported by the target. #HeaderDigest "None" — default. CRC not enabled. "CRC32C" — Indicates Target will support CRC32C checksum to protect iSCSI PDU’s headers, if requested by initiator.

Notes: (1) data digests are not used during discovery sessions. (2) CRC32C may negatively affect overall target performance. #Wthreads Default: 8 Sets the number of threads used to perform the block I/O to the blades’ disk resources. 8 threads was determined optimal for the majority of deployments and workloads. Lun Path=,Type,ScsiID= defines a mapping between a Logical Unit Number and a block device . : The value between 0 and 2^14-1 : Linux device path mapped to the LUN Indicates the blade will perform direct block i/o with the device, bypassing page-cache for all operations. Optimal for non-aligned sector transfers large block transfers. a unique ID assigned to the iSCSI volume. It is required to assist mulitipath-aware initiator host accessing the same through several targets. The must not exceed 16 characters.

Page 98 of the Emerson ATCA-S201 user manual — /etc/initiators.deny
Page 98 · click to enlarge
Page 98

7.1.6 iSCSI Discovery filter configuration (expert mode)

The iSCSI service running on the storage blade includes the ability to limit the targets each host will see during discovery; this can often significantly reduce the iSCSI boot time. The filter mechanism uses the host IP address as criteria to expose or hide iSCSI targets listed in discovery.

The iSCSI discovery filter is configured via simple edits to a pair of text based configuration files: /etc/initiators.allow /etc/initiators.deny

The file syntax is explained in the next section. File changes become active immediately upon save, no reboot is necessary.

/etc/initiators.allow

Enter the iSCSI iqn followed by one or more ip addresses. Use a comma to separate multiple IP address entries. (Note: Entries must not use tabs) iqn.1995-07.com.emerson:BladeHost.Target0 192.168.1.109 iqn.1995-07.com.emerson:BladeHost.Target1 192.168.1.108, 192.168.1.110

/etc/initiators.deny

For each iSCSI iqn listed above, make a corresponding entry as shown. Each entry should consist of the iSCSI iqn, followed by the word ALL (Note: Entries must not use tabs). iqn.1995-07.com.emerson:BladeHost.Target0 ALL iqn.1995-07.com.emerson:BladeHost.Target1 ALL

Page 99 of the Emerson ATCA-S201 user manual — 8.1 NFS and SMB mount point configuration menus
Page 99 · click to enlarge
Page 99

8 NFS/SMB Share setup tools

Configuration Step:

Emerson ATCA-S201 — Configuration Step: diagram (page 99)
Fig. 43 · Configuration Step:

This chapter explains how to establish NFS and SMB mount points for external host access. The configuration menus for the NFS and SMB services are nearly identical, and will be discussed together. The user must complete step 4 before this step can be accomplished.

Emerson ATCA-S201 — Configuration Step: diagram (page 99)
Fig. 44 · Configuration Step:

8.1 NFS and SMB mount point configuration menus

Using the HTML configuration tool, navigate to either of these configuration pages:

Emerson ATCA-S201 — 8.1 NFS and SMB mount point configuration menus diagram (page 99)
Fig. 45 · 8.1 NFS and SMB mount point configuration menus
Emerson ATCA-S201 — 8.1 NFS and SMB mount point configuration menus diagram (page 99)
Fig. 46 · 8.1 NFS and SMB mount point configuration menus

iSCSI nfs nfs Configuration Smb smb Configuration Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

Page 100 of the Emerson ATCA-S201 user manual — ˇ
Page 100 · click to enlarge
Page 100

These menus provides the ability to create file mount points for logical devices previously committed for file I/O share (see chapter 6 ).

8.1.1 Export an nfs or smb share

These are the final steps to make an nfs or smb share ‘appear’ on the IP network.

Follow these instructions to create a new nfs File-Share Export

nfs menu Emerson ATCA-S201 nfs nfs Configuration Use the ‘nfs’ configuration menu to export shares to OS’s using network file services, such as Linux or Solaris®.

StorBlade99 ATCA-S201 Network File Share (nfs) Configuration

ˇ

Figure 28 HTML tool, Emerson ATCA-S201 nfs nfs Configuration

1. Choose the logical device from the drop down menu that will map to this

export.

2. Click the ‘Add nfs Export’ button.

After confirming the popup, the configuration tool page changes, and will display the newly created export along with several export attributes.

Export Name Client List Access Attributes Action

/export/nfs/lvb0 Remove Update * (rw,sync,no_wdelay,root_squash)

3. Enter one or more client names (separated by commas) in the client list box
4. Adjust the “Access Attributes” if desired. The default attributes include:

(rw,sync,no_wdelay,root_squash) Syntax note: attributes must be in parenthesis, with no white spaces.

5. Left click the update button
Show 4 more labels / short text on this page
nfs menu · Add nfsExport lvb0 · nfs export /export/nfs/lvb0 · Update
Page 101 of the Emerson ATCA-S201 user manual — ˇ
Page 101 · click to enlarge
Page 101

Table 34 CLI command syntax, create nfs share Convention: atca_blade set_nfs This command invokes an interactive session to modify the nfs setting of the blade. The command will spawn a series of Yes/No questions which guide the user the nfs configuration options. The command session and responses can be scripted to automate a common configuration setup on multiple blades.

Follow these instructions to create a new smb File-Share Export

smb menu Emerson ATCA-S201 smb smb Configuration Use the ‘smb’ configuration menu to export shares to OS’s using Server Message Block services, such Microsoft® Windows®.

StorBlade99 ATCA-S201 Network File Share (smb/cifs) Configuration

Security share Guest Access Yes

Workgroup WORKGROUP Netbios Name PPCSAMBA

Log Level 1 Log Size 100

Allowed Hosts ALL Denied Hosts NONE

Share Device Share Name

ˇ

Figure 29 HTML tool, Emerson ATCA-S201 smb smb Configuration

1. Choose the logical device from the drop down menu that will map to this

export.

2. Click the ‘Add nfs Export’ button.

After confirming the popup, the configuration tool page changes, and will display the newly created export along with several export attributes.

Public Access Guest Access

Open format comment field

3. Adjust the “Access Attributes” if desired.
4. Left click the update button
Show 8 more labels / short text on this page
CLI command syntax · Add smbExport lvb0 · Share0 · Name=Share0 path=/export/smb/Fileshare · Delete · Update · Read Only Browseable · Comment
Page 102 of the Emerson ATCA-S201 user manual — 8.1.2 Remove an individual file-share Export
Page 102 · click to enlarge
Page 102

Table 35 CLI command syntax, create smb share Convention: atca_blade set_smb This command invokes an interactive session to modify the smb setting of the blade. The command will spawn a series of Yes/No questions which guide the user the smb configuration options. The command session and responses can be scripted to automate a common configuration setup on multiple blades.

8.1.2 Remove an individual file-share Export

The user can remove any export from operation by opening the nfs or smb configuration menu. All data on these exports is NOT lost. It is merely made unavailable and can be exported again at a later time.

Follow these instructions to Delete a file-share export

1. Click the ‘Delete this Export’ button corresponding to the export you will

remove. Confirm the popup message.

CLI command syntax

Page 103 of the Emerson ATCA-S201 user manual — 8.1.3 Advanced file share configuration (expert mode)
Page 103 · click to enlarge
Page 103

8.1.3 Advanced file share configuration (expert mode)

The file share services running on the storage blade supports numerous configuration features that are not part of the web interface tool, but available via simple edits to a text based configuration file using a console window.

File share service Configuration file

Samba (cifs) /etc/samba/smb.conf

The configuration file contains an entry for each target entry created by the web or cli tools. The file syntax explanations follow in the next section.

Sample smb.conf file for samba/CIFs file shares

Comment lines must start with a ‘#’ or “;” as first character. A line may extend across multiple lines if last character is backslash ‘\’ Parameter names are case insensitive

The configurations applicable to this product are contained in the [global] section. [global] security = share interfaces = 192.168.1.152/255.255.255.0 workgroup = WORKGROUP netbios name = PPCSAMBA hosts deny = NONE hosts allow =ALL

1. Parameter and content definitions for this file is available online:

http://us1.samba.org/samba/docs/man/manpages-3/smb.conf.5.html

Sample /etc/export file for nfs file shares

Comment lines must start with a ‘# ’ as first character. A line may extend across multiple lines if last character is backslash ‘\’

The /etc/exports file facilitates the export of file systems to remote hosts, with various user options. Each exported file system should be on its own individual line, with lists of authorized hosts placed after an exported file system, with each entry delimited by spaces. Options for each of the hosts is placed in parentheses directly after the host identifier, without any spaces separating the host and the first parenthesis. -sh-2.05b# cat exports

nfs /etc/exports

Page 104 of the Emerson ATCA-S201 user manual — 8.1.3 Advanced file share configuration (expert mode)
Page 104 · click to enlarge
Page 104

Export option syntax:

Table 36 Common nfs export option definitions host1-hostN Host specifies the directory on the storage blade that is the target of the export. Option <wdelay|no_wdelay> no_wdelay- (default) option turns off the delayed writes feature; no_wdelay must be accompanied with the sync option. wdelay- option causes the NFS server to delay writing to the disk if it suspects another write request is imminent. This can improve performance by reducing the number of times the disk must be accessed by separate write commands, reducing write overhead. Option <root_squash> This default setting prevents root users connected remotely from having root privileges and assigns them the user ID for the user nfsnobody. This effectively "squashes" the power of the remote root user to the lowest local user, preventing unauthorized alteration of files on the ATCA storage blade. Option <ro|rw> ro - Mounts of the exported file system are read-only. Remote hosts are not able to make changes to the data shared on the file system. rw- (default) Mounts of the exported file system are read/write. Remote hosts are able to make changes to data shared on the file system Option <sync> The sync setting (default) instructs the Linux kernel to minimize the amount of write data kept in volatile system memory. Though it is sometimes slower to complete all writes to disk, doing so can prevent data loss in the event of a power failure.

/export/nfs/Fileshare nfs_share1(rw,sync,no_wdelay,root_squash) · () ()

Page 105 of the Emerson ATCA-S201 user manual — 9.1.1 Backup your blade configuration
Page 105 · click to enlarge
Page 105

9 Blade Maintenance and Firmware upgrades

This chapter provides information about preserving all existing blade configuration settings and also installing and updating the firmware loaded on the ATCA-S201 storage services blade. At manufacturing time, the ATCA carrier is pre-loaded with firmware prior to shipping. Periodically, new firmware releases are offered to improve the functionality or performance of the ATCA carrier blade.

9.1 Blade Maintenance

The following section describes how to create a backup of an existing blade configuration and how to restore this configuration on a replacement blade. The procedure will record the iSCSI, NAS, volume, and share privileges of all disk storage connected to the ATCA-S201. Moreover, it will record IP attributes of all fabric, base and RTM Ethernet ports, as well as any VLAN, bonds or RAID definitions.

9.1.1 Backup your blade configuration

The ATCA-S201 blade software keeps all system configuration data in a single archive file. This file contains all customizations made by the user over the life of the blade. Administrators can manually copy this file to a safe location and later reload the configuration if needed.

The following procedure is a detailed description of the web-based export system configuration procedure.

Export System configuration file using web-GUI tool

2. Navigate to the Maintenance menu. Click the ‘Export’ button.
3. Acknowledge the popup window to confirm and commence the export.

The action will create a backup file on the host which can be later imported.

iSCSI nfs smb Shares LVM2 MD RAID Hardware RAID Physical Disks Maintenance

StorBlade99 ATCA-S201 System Maintenance

Export System Configuration /backup/nvdisk.tar.gz

Show 18 more labels / short text on this page
Emerson ATCA-S201 · ‐ · + · + · Import Software Update · Browse… · Import · + · + · Import System Configuration · Browse… · Import · + · + · Export · + · ‐ · +
Page 106 of the Emerson ATCA-S201 user manual — 9.2 ATCA Firmware
Page 106 · click to enlarge
Page 106

Export system configuration file using CLI

The following procedure is a detailed description of the CLI-based export system configuration procedure.

4. On your remote host, open a secure ftp connection.

sftp [email protected]

5. Set binary mode and copy file

bin get /backup/nvdisk.tar.gz

9.1.2 Import (restore) a blade configuration

The following procedure is a detailed description of the web-based import system configuration procedure.

Import System configuration using web-GUI tool

6. Navigate to the Maintenance menu. Click the ‘Browse’ button, navigate to

find the new *.gz firmware file.

7. Click the ‘Import’ configuration button.
8. A popup will confirm successful import.

Import System configuration using CLI

9. Open a secure ftp connection. (Note: Substitute the proper IP address)

sftp [email protected]

10. Change remote directory cd /dev/shm
11. Set binary mode and copy file bin put nvdisk.tar.gz exit
12. Open a secure remote shell. (Note: Substitute the proper IP address) ssh –l admin 192.168.100.100
13. Un-tar the config file tar –C / –xvf /dev/shm/nvdisk.tar.gz

9.2 ATCA Firmware

All firmware code is stored in a single EEPROM flash device located on the carrier blade. The ATCA-S201 flash device is partitioned into regions containing the following code functions:

U-boot Linux Kernel (kernel) Root file system and storage applications (rfs) Non-Volatile blade configuration Data (NVDATA)

Page 107 of the Emerson ATCA-S201 user manual — 9.3.1 Web flash tool, update procedure details
Page 107 · click to enlarge
Page 107

Each image contains a CRC signature which is validated by the system prior to loading. The normal methods for updating these code images is to establish a management connection, ( see chapter 3 ) login as administrator, and utilize either the command line interface (CLI) or web-based graphical user interface (GUI) interface outlined later in this chapter . Both of these mechanisms require that the existing firmware is known-good and intact.

Additionally, an alternate emergency recovery method is provided to repair flash contents that are blank, erased or corrupted.

9.2.1 Download New Firmware package

To begin, the user must first download new ATCA firmware component(s). Please contact your Emerson Networks sales person for access.

9.2.1.1 Identifying the correct firmware image

The download area contains firmware for several products. Locate the latest firmware for the ATCA-S201. Emerson distributes the code as gunu-zip (*.gz) file. The distribution will contain the following three files:

Rootfs.ext.gz.uboot compressed file system firmware image file (version denoted by timestamp) uImage Compressed linux kernel firmware image U-boot.bin Compressed u-boot firmware code image

9.3 Normal Firmware Update procedures

Two methods exist for upgrading the firmware on the ATCA-S201, one that is web based and one that is command line. Both are equally effective, and both require root administration privileges.

9.3.1 Web flash tool, update procedure details

Emerson offers the ability to update the carrier firmware using secure html connections. The user must establish Web access to use this utility. (See chapter 3 New System configuration 3 . The following procedure is a detailed description of the web-based flash update procedure:

File Description

Page 108 of the Emerson ATCA-S201 user manual — Browse…
Page 108 · click to enlarge
Page 108

StorBlade99 ATCA-S201 Maintenance Page

File Name Revision Build Date

Software Release kit V.1.0rc7 Date2009/07/21 20:05:48

U‐boot 1.3.0 Apr 27 2009 – 17:44:03

Linux 2.6.23 #28 Wed Jul 1 09:09:29 EDT 2009

atca_blade Revision1.73 Date: 2009/07/21 20:05:48

Software reset SAS controller

StorBlade99 ATCA-S201 System Maintenance

Browse…

Export System Configuration /backup/nvdisk.tar.gz

Follow these instructions to load new firmware

1. Click the ‘Browse’ button, navigate to find the new *.gz firmware file.
2. Click the ‘Import’ button. The import can take 1 to 5 minutes; the user

must wait, and not navigate away from the open browser window.

3. The following screen will appear. Click the software component(s) to

upgrade and click the ‘Update’ button.

StorBlade99 ATCA-S201 System Maintenance

/dev/shm/ATCA-S201_V1.0rc7/u-boot

/dev/shm/ATCA-S201_V1.0rc27uImage_2.6.23

/dev/shm/ATCA-S201_V1.0rc27rootfs

Export System Backup /backup/nvdisk.tar.gz

Show 12 more labels / short text on this page
Upgrade firmware procedure · Reset IO Counters · Rescan SAS topology · Import Software Update · Browse… · Import · Import System Configuration · Import · Export · Apply Software Update · Update · Export
Page 109 of the Emerson ATCA-S201 user manual — DESCRIPTION
Page 109 · click to enlarge
Page 109

A Pop-up window notifies the user when the flash update completes. The new software becomes active at next reboot. A blade reboot button is available on the ‘ATCA Status’ menu (see

StorBlade99 ATCA-S201 Blade 1 (0x96) Status

Vendor IANA ID Name HW Revision

H8 FW Revision IPMI Rev Model Serial

Emerson 65cd ATCA‐S201 0004 01.10 01.50 ATCA‐S201 100LYMMSSSS

AMC Site B1 (0x7a) Configuration Phy Num Type SAS Address Handle Parent Disk 00 SAS 5000cca000784c49 0009 0001 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B2 (0x7c) Configuration Phy Num Type SAS Address Handle Parent Disk 01 SAS 500000e016cbd032 000a 0002 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B3 (0x7e) Configuration Phy Num Type SAS Address Handle Parent Disk 02 SAS 5000c50005b18665 000b 0003 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B4 (0x80) Configuration Phy Num Type SAS Address Handle Parent Disk 03 SAS 500000e016cbd982 000c 0004 Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson AMC‐S402 0106825G 068NYMxxxx Enabled True Site Control

AMC Site B5 (0x8e) Configuration Vendor Product Model Serial State Present MgEna MgOK PayEna PayOK AMC State Emerson RTM 0106828G 401NYMxxx Enabled True Site Control

4. Figure 14), or via shell console prompt using:

9.3.2 flash_update.sh tool usage and options

Emerson offers a shell script (.sh) to update firmware code stored in flash. This command line script is named sbflash, and is located on the /bin directory of the ATCA-S201.

SYNOPSIS sbflash [-r] [-k] [-u] [-t tftp_serverIP]

DESCRIPTION

sbflash is a shell script which enables the user to selectively update some or all of the firmware components. A blade reboot is required to activate the new firmware components.

Show 14 more labels / short text on this page
Refresh · Reboot · Power Off · Enable · Disable · Enable · Disable · Enable · Disable · Enable · Disable · Enable · Disable · # reboot
Page 110 of the Emerson ATCA-S201 user manual — 9.3.3 CLI flash tool, update procedure details
Page 110 · click to enlarge
Page 110

OPTIONS -r: indicates the root file system should be replaced with the image on the tftp server.

-k: indicates the linux kernel should be replaced with the image on the tftp server.

-u: indicates the uboot components should be replaced with the image on the tftp server.

-t tftp_serverIP: used to specify the dotted decimal IP address of the remote tftp server. (example -t 192.168.1.151). If this option is omitted, the script will search for tftp at the IP address assigned to U-boot variable assignment for serverip.

Example #1: flash new root file system and kernel from specified tftp server sbflash –r –k –t 192.168.1.151

9.3.3 CLI flash tool, update procedure details

The following procedure is a detailed description of the CLI flash update procedure:

1. Establish console or ssh access to the ATCA-S201. Must be user root.
2. Install a second host machine on the same IP network as the ATCA-S201. This machines IP address must be visible from the ATCA-S201. Use ping to validate it is accessible. (e.g. ping 192.168.xxx.xxx)
3. Load the second host machine with TFTP server software. A good quality tftp program is offered by PumpKIN, an open source and free implementation that is written to RFC1350.
4. Copy all new firmware file to the secondary host machine named /tftpboot/
5. Execute the following command from the ATCA-S201 shell # # sbflash -t 192.168.1.151 –r

uboot_flash=/dev/mtd4 rootfs_flash=/dev/mtd2 kernel_flash=/dev/mtd1 Will use TFTP Server 192.168.1.151 Writing root file system image rootfs.ext2.gz.uboot to /dev/mtd2 File rootfs.ext2.gz.uboot not found on local system, try tftp from 192.168.1.151 Successful tftp get of rootfs.ext2.gz.uboot Updating Flash /dev/mtd2 from file rootfs.ext2.gz.uboot ************************************************* Do not interrupt this process * * or the system will be unbootable *

Upgrade firmware procedure

Page 111 of the Emerson ATCA-S201 user manual — 9.4.1 Jumper Settings
Page 111 · click to enlarge
Page 111

* * ************************************************* Erasing 256 Kibyte @ 31c0000 -- 99 % complete. Programming /dev/mtd2 Verifying rootfs.ext2.gz.uboot Successful update of flash /dev/mtd2 from file rootfs.ext2.gz.uboot /nvdisk/mnt #

9.4 Emergency firmware recovery, theory of operation

The ATCA-S201 hardware actually contains two copies of flash code. The primary image used for normal customer carrier operation, while the second image contains a backup copy preserved for emergency firmware recovery tasks. The contents of the backup flash remain fixed at time of manufacturing and there is no end-user mechanism to modify its contents. This ensures the device is not accidentally re- written or erased. A jumper on the ATCA blade is used to instruct the CPU to boot either the primary flash (normal) or the secondary flash (emergency recovery).

9.4.1 Jumper Settings

The ATCA-S201 carrier board includes jumpers that are used for special recovery and reset procedures. Jumper locations are shown in Figure 30. Jumpers create an electrical connection between two pins which can be sensed by circuitry on ATCA- S201 to enter special service modes or behavior. Pin 1 is identified with a square solder pad on the printed circuit board. Jumper behavior is described below.

Table 37 JP1, jumper for primary/recovery Flash selection JP1 Jumper Setting

Short Pin 1-2 Normal setting. When in this position, the jumper indicates that boot is loaded from the primary flash device.

Short Pin 2-3 Service setting. When in this position, the jumper indicates that boot code is loaded from the secondary flash device.

Table 38 JP2, jumper for clearing master password JP2 Jumper Setting

Short Pin 1-2 Normal setting. When in this position, the jumper indicates the master password is preserved in flash.

Short Pin 2-3 Service setting. When in this position, the jumper indicates the master password shall be cleared.

Description · Description

Page 112 of the Emerson ATCA-S201 user manual — 9.4.2 Emergency flash recovery (factory reset)
Page 112 · click to enlarge
Page 112
Emerson ATCA-S201 — 9.4.2 Emergency flash recovery (factory reset) diagram (page 112)
Fig. 47 · 9.4.2 Emergency flash recovery (factory reset)

JP1

Emerson ATCA-S201 — JP1 diagram (page 112)
Fig. 48

J30

DDR2 DIMM

Emerson ATCA-S201 — J30 diagram (page 112)
Fig. 49

JP2

J32

CPU

J33

SAS

J23

J10

Emerson ATCA-S201 — J32 diagram (page 112)
Fig. 50

ATCA-S201

Figure 30 ATCA-S201 Jumper locations

9.4.2 Emergency flash recovery (factory reset)

The method described in this section explains a procedure to repair primary flash contents that are blank, erased or corrupted. We advise against using this emergency recovery procedure if the ATCA-S201 is functional, and management communications can be conducted.

1. Remove the ATCA carrier the chassis (see 2.9, Removing the ATCA carrier blade)
2. Locate header JP1, and move the jumper to the service setting. This causes the blade to fetch firmware from the read-only factory flash.
3. Re-install the ATCA blade into the chassis and allow it to reboot.
Show 7 more labels / short text on this page
AMC slot B1 · PCIe Switch · AMC slot B2 · AMC slot B3 · 10GbE XAUI · AMC slot B4 · Upgrade firmware procedure
Page 113 of the Emerson ATCA-S201 user manual — 9.4.3 Clear root password
Page 113 · click to enlarge
Page 113
4. The ATCA blade will break into the U-boot console.
5. Establish a serial connection, login into the blade as root (see section 3.2)
6. Use printenv to list the environment variables. Assign a serverip address to match the tftp server address in the next step , for example: setenv serverip 192.168.xxx.xxx
7. Install a second host machine on the same IP network as the ATCA-S201. Its IP address must match the serverip address listed in the previous step.
8. Load the second host machine with TFTP server software. A good quality tftp program is offered by PumpKIN, an open source and free implementation that is written to RFC1350.
9. If necessary create a directory on the secondary host machine named /tftpboot/
10. Place the new blade firmware image(s) for the primary flash device in /tftpboot/
11. When all pieces are in place, go to U-boot console and type: run ramboot
12. Watch U-boot console, and wait for output message: “Primary flash successfully restored”
13. Remove the ATCA carrier the chassis
14. Locate header JP1, and move the jumper to the normal setting.
15. Re-install the ATCA blade into the chassis and allow it to reboot normally.

9.4.3 Clear root password

For security purposes, administrators are encouraged to change factory default passwords to protect unauthorized access and configuration of the storage blades resources. The method described in this section explains a procedure to clear the blades root password to factory default. None of the other user account passwords are cleared.

root password reset procedure (method 1)

This procedure is useful when the user has no access to the RTM serial console port.

1. Remove the ATCA carrier the chassis (see 2.9, Removing the ATCA carrier blade)
2. Locate header JP2, and move the jumper to the service setting.
3. Re-install the ATCA blade into the chassis and allow it to reboot.
4. Inspect the LED’s on the front panel. When the ATCA Health status begins blinking green, the password reset has occurred.
5. Power down the blade and again remove it from the chassis.
6. Locate header JP2, and move the jumper to the normal setting.
7. Re-install the ATCA blade into the chassis and allow it to reboot.
Page 114 of the Emerson ATCA-S201 user manual — Clear root password
Page 114 · click to enlarge
Page 114
8. Administrators may login as root. There is no password, and the ‘root’ user will be asked to create one.

root password reset procedure (method 2)

This procedure is useful when the user has access to the serial console port and can operate the U-boot environment. This secondary method allows you to clear the root password without removing the blade from the chassis but does require a power cycle and some familiarity with U-boot.

1. Establish a connection to the serial port (RS232)
2. Reboot the blade: # reboot
3. Stop the normal boot sequence; enter the U-boot menu. (see section 3.6.1)
4. Type the following series of U-boot commands: uboot=> setenv resetroot 1 uboot=> run flashboot

The above commands will continue the boot sequence and trigger the blades Linux file system to clear the root password. No other passwords are cleared. Do not use saveenv after setting resetroot, otherwise the root password will be reset on every re-boot.

Page 115 of the Emerson ATCA-S201 user manual — 10.1.3 Environmental Specifications and Compliance
Page 115 · click to enlarge
Page 115

10 ATCA-S201 Mechanical and Connector Information

This chapter provides the specifications and connector pin outs for the ATCA-S201 module.

10.1 Specifications for the ATCA-S201

This section provides mechanical, electrical, environmental, and other relevant physical information.

10.1.1 Physical dimensions

The ATCA-S201 is an 8U (280 mm) height board with 325 mm in depth for standard applications. It complies with IEEE 1101.11 mechanical standards, as required by the PICMG 2.0 Revision 3.0 specification. The ATCA-S201 is keyed to conform to the PICMG 2.10, Keying of ATCA Boards and Backplanes specification.

10.1.2 Power Requirements

The ATCA-S201 includes a stacked power supply module with maximum rated output of 210 W of power. This represents a surplus of power vs. the expected power consumption. The power consumption of the RTM is limited to 25 W maximum. The unpopulated base blade (no AMC or RTM) blade will consume 1.04 A at 48 V (50 W).

10.1.3 Environmental Specifications and Compliance

The environmental specifications for the ATCA-S201 assembly are presented in the table below.

Page 116 of the Emerson ATCA-S201 user manual — 10.1.5 Electromagnetic Compliance
Page 116 · click to enlarge
Page 116

ATCA-S201 Mechanical and Connector Information

Table 39 Environmental specifications for the ATCA-S201 SPECIFICATION VALUE Operating Temperature (airflow 5.0 CFM)

0°C ~ 55 °C

Operating Temperature (airflow 2.0 CFM)

0°C ~ 23 °C

Storage Temperature -40 °C ~ 85 °C Operating Temperature Gradient 11 °C /H (max) Storage Temperature Gradient 20 °C /H (max) Shipping Temperature Gradient 20 °C /H (max) *1 Operating Humidity 8 % ~ 80 % Storage Humidity 5 % ~ 95 % Shipping Humidity 5 % ~ 95 % *1 Wet bulb Maximum Temperature 27 °C Condensation No condensation Atmospheric Pressure and Altitude Operating: 0 ~ 3,000 m Shipping: 0 ~ 12,000 m Operating Shock

See PICMG 3.0 specification, Regulatory guidelines.

Operating Vibration See PICMG 3.0 specification, Regulatory guidelines. RoHS 6 of 6 compliant. Operating voltage -36 to -72 Vdc Operating power 3.12@48V = 150W max total, shared as follows:

Max ATCA blade Current Draw

1.04 @ 48V (50 watts)

Max current draw (each AMC slot) 72 watts (max each) Max current draw (ARTM slot) 25 watts max 100 watts total shared power pool Reliability MTBF: 229481 Hours

10.1.4 NEBS Compliance

NEBS certifications are performed by integrator at a system level (chassis, ATCA, AMC shelf managers etc) The RTM module will not preclude the system from passing NEBS.

10.1.5 Electromagnetic Compliance

The board is designed and implemented so as to minimize electromagnetic emissions, susceptibility, and the effects of electrostatic discharge. The board carries the following certifications:

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 106

(unpopulated)

Page 117 of the Emerson ATCA-S201 user manual — 10.2 Connectors and Pin assignments
Page 117 · click to enlarge
Page 117

Table 40 EMC Emission compliancy

USFCC 47 CFR Part 15 Class A FCC Class A emissions requirements (United States)

ICES-003 2004 Class A Class A Interference-causing Equipment standard (Canada) VCCI V-3/2007.04 Class A Class A ITE emissions requirements (Japan) Europe Commercial: EN5022:2006 Class A, ITE Class A ITE emissions requirements (EU, Europe) AS/NZS CISPR 22:2005 Class A, ITE Class A ITE emissions requirements (Australia) Europe Commercial: EN 55022:1998/A1:2000/A2:2003 Immunity for ITE equipment Europe Commercial: EN 55024:1998A1:2001/A2:2003 Immunity for ITE equipment Europe Commercial: EN 61000-4-2,3,4,5,6 ,11: 2001 EMC Electrostatic discharge immunity

Europe CommercialEN6100-3-2, 2000 Section 2 With A2 (2005) Limits for harmonic current emissions
Europe CommercialEN6100-3-3, 2000 Section 3 With A2 (2005) limits for voltage fluctuations and flicker

10.2 Connectors and Pin assignments

This section provides position and pin-out details of all connectors available on the ATCA-S201.

Description Description

Page 118 of the Emerson ATCA-S201 user manual — AMC.1 SAS/SATA
Page 118 · click to enlarge
Page 118

Table 41 Connector Port Identification and Location 1 AMC Slot 0 7 Zone 3, J32 RTM signal connector 2 AMC Slot 1 8 Zone 3, J33 RTM signal connector 3 AMC Slot 2 9 Zone 2, J23 Chassis connector 4 AMC Slot 3 10 Zone 1, J10 Power supply connector 5 SODIMM, DDR2 socket 11 Power supply mezzanine module 6 Zone 3, J30 RTM power connector

Emerson ATCA-S201 — 10.2.1 AMC Module Slots diagram (page 118)
Fig. 51 · 10.2.1 AMC Module Slots
Emerson ATCA-S201 — 10.2.1 AMC Module Slots diagram (page 118)
Fig. 52 · 10.2.1 AMC Module Slots

Figure 31 ATCA-S201 ATCA Module Connectors

10.2.1 AMC Module Slots

The ATCA-S201 can accept up to four mid-height single width AMC modules. Each slot is routed with PCI Express (AMC.1) and storage (AMC.3) signaling.

AMC.1 SAS/SATA

Channel 2 of the AMC slots is allocated for SAS signaling. All four AMC are connected to the SAS Controller located on the ATCA carrier. Channel 3 of the AMC slots is allocated for SAS signaling. A manufacturing option is available to provide ONE of the following configurations:

Port 3 is routed to the on board SAS Controller. Port 3 is routed to the Zone 3 RTM connector.

Page 119 of the Emerson ATCA-S201 user manual — 10.2.1.2 AMC slot B2, Port Assignments
Page 119 · click to enlarge
Page 119

AMC.3 PCI Express

All four slots implement a x4 PCIe connection on channels 4 to 7. All slots are directly connected to the PCI Express switch located on the ATCA carrier.

10.2.1.1 AMC Slot B1, Port Assignments

Table 42 AMC Slot 0, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 0 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0, port 14 15 EXTENDED --

5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --

10.2.1.2 AMC slot B2, Port Assignments

Table 43 AMC Slot 1, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 1 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0, port 13 15 EXTENDED --

5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --

Page 120 of the Emerson ATCA-S201 user manual — 10.2.2 Zone 1 Connectors
Page 120 · click to enlarge
Page 120

10.2.1.3 Port Assignments for AMC Slot B3

Table 44 AMC slot 2, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 2 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0 15 EXTENDED -- 5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --

10.2.1.4 AMC Slot B4, Port Assignments

Table 45 AMC slot 3, Port Assignments Port# Region Port Mapping Port# Region Port mapping CLK1 CLOCK -- 8 AMC-AMC -- CLK2 CLOCK -- 9 AMC-AMC -- CLK3 CLOCK PCI Express Clock 10 AMC-AMC -- 0 COMMON -- 11 AMC-AMC -- 1 COMMON -- 12 EXTENDED -- 2 COMMON SAS/SATA Controller Port 3 13 EXTENDED -- 3 COMMON SAS/SATA Controller on RTM 14 EXTENDED -- 4 FAT PIPE PCI-Express PEX Switch Lane0 15 EXTENDED -- 5 FAT PIPE PCI-Express PEX Switch Lane1 16 EXTENDED -- 6 FAT PIPE PCI-Express PEX Switch Lane2 17 EXTENDED -- 7 FAT PIPE PCI-Express PEX Switch Lane3 18 EXTENDED -- 19 EXTENDED --

10.2.2 Zone 1 Connectors

The ATCA-S201 includes a standard zone 1 connector designated as J10 on the ATCA board. This connector is implemented with a 30-pin male connector type available from Positronics industries (http://www.connectpositronic.com), part number VPB30W8M400A1.

Page 121 of the Emerson ATCA-S201 user manual — 10.2.3 Zone 2 Connectors
Page 121 · click to enlarge
Page 121
Emerson ATCA-S201 — 10.2.3 Zone 2 Connectors diagram (page 121)
Fig. 53 · 10.2.3 Zone 2 Connectors

1 5 9 13

4 8 12 16 17 18 19 20

2 6 10 14

3 7 11 15

21 22 23 24

ATCA PCB

Emerson ATCA-S201 — ATCA PCB diagram (page 121)
Fig. 54

Figure 32 Zone 1 J10 Connector Port Pin Location Diagram

Table 46 Connector J10, Zone-1 Pin Assignments Pin# Signal Pin# Signal Pin# Signal Pin# Signal 1 NC 10 PP_HA5 19 NC 28 VRTN_A 2 NC 11 PP_HA6 20 NC 29 VRTN_B 3 NC 12 PP_HA7 21 NC 30 N48V_A 4 NC 13 PP_IPMB_SCL_A 22 NC 31 N48V_B 5 PP_HA0 14 PP_IPMB_SDA_A 23 NC 32 PPENABLE_A 6 PP_HA1 15 PP_IPMB_SCL_B 24 NC 33 N48V_A 7 PP_HA2 16 PP_IPMB_SDA_B 25 Shelf Ground 34 N48V_B 8 PP_HA3 17 NC 26 Logic Ground 9 PP_HA4 18 NC 27 PPENABLE_B

Emerson ATCA-S201 — ATCA PCB diagram (page 121)
Fig. 55

10.2.3 Zone 2 Connectors

The ATCA-S201 provides Ethernet fabric and base ports on the Zone-2 connector designated as J23 on the ATCA board. This connector is implemented with a 4-pin per column type available from Tyco electronics (http://www.tycoelectronics.com), part number 6469081-1.

ATCA Receptacle view

Page 122 of the Emerson ATCA-S201 user manual — 10.2.4 Zone 3 Connectors
Page 122 · click to enlarge
Page 122
Emerson ATCA-S201 — 10.2.4 Zone 3 Connectors diagram (page 122)
Fig. 56 · 10.2.4 Zone 3 Connectors

1 2 3 4 5 6 7 8 9 10

J23

Row H G F E D C B A

Figure 33 Zone 2 Connector Port Pin Location Diagram

Table 47 Connector J23, Zone-2 Pin Assignments Row# Interface A B C D E F G H 1 XAUI_0 TX2+ TX2- RX2+ RX2- TX3+ TX3- RX3+ RX3- 2 XAUI_0 TX0+ TX0- RX0+ RX0- TX1+ TX1- RX1+ RX1- 3 XAUI_1 TX2+ TX2- RX2+ RX2- TX3+ TX3- RX3+ RX3- 4 XAUI_1 TX0+ TX0- RX0+ RX0- TX1+ TX1- RX1+ RX1- 5 BASE0 MDIO0+ MDIO0- MDIO1+ MDIO1- MDIO2+ MDIO2- MDIO3+ MDIO3- 6 BASE1 MDIO0+ MDIO0- MDIO1+ MDIO1- MDIO2+ MDIO2- MDIO3+ MDIO3- 7 - 8 - 9 - 10 -

Emerson ATCA-S201 — J23 diagram (page 122)
Fig. 57

Table 48 Connector J23, Zone-2 Signal Descriptions XAUI_0 Fabric Port 0, 10GbE XAUI TX and Rx signals XAUI_1 Fabric Port 1, 10GbE XAUI TX and Rx signals BASE_0 Base Port 0, 1GbE, MDIO interface signals. For Star or dual star backplanes BASE_1 Base Port 1, 1GbE, MDIO interface signals. For Star or dual star backplanes

10.2.4 Zone 3 Connectors

The ATCA-S201 routes several I/O signals to the zone 3 connector complex consisting of connectors J30, J32 and J33. These connectors enable future expansion using advanced rear transition modules (RTM) whose ‘J’ connectors mirror the ‘P’ connectors located on the carrier module. All of these connectors utilize a 3-pin per column type available from Tyco electronics (http://www.tycoelectronics.com), part number 6469081-1 .

ATCA Receptacle view

Page 123 of the Emerson ATCA-S201 user manual — 10.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments
Page 123 · click to enlarge
Page 123
Emerson ATCA-S201 — 10.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments diagram (page 123)
Fig. 58 · 10.2.4.1 Connector P32, Storage and Management Infra…

1 2 3 4 5 6 7 8 9 10

J32

ATCA PCB

Emerson ATCA-S201 — ATCA PCB diagram (page 123)
Fig. 59

1 2 3 4 5 6 7 8 9 10

J33

Row F E D C B A

Figure 34 Zone 3, Connector Port Pin Location Diagram

10.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments

The ATCA-S201 P32 connector pin assignments and descriptions appear below.

Table 49 Connector P32, Management infrastructure pin assignments Row# Interface A B C D E F

Emerson ATCA-S201 — 10.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments diagram (page 123)
Fig. 60 · 10.2.4.1 Connector P32, Storage and Management Infra…

3 SAS-out SAS_TX1+ SAS_TX1- SAS_RX1+ SAS_RX1- UART_TXD0 UART_RXD0 4 SAS-out SAS_TX2+ SAS_TX2- SAS_RX2+ SAS_RX2- NC UART_CTS0# 5 SAS-out SAS_TX3+ SAS_TX3- SAS_RX3+ SAS_RX3- NC NC 6 LAN0 LAN0_MDIO0+ LAN0_MDIO0- LAN0_CTV LAN0_CTV LAN0_MDIO1+ LAN0_MDIO1- 7 LAN0 LAN0_MDIO2+ LAN0_MDIO2- LAN0_LEDACT# LAN0_LEDLNK# LAN0_MDIO3+ LAN0_MDIO3-

9 SAS-in AMC1_TX3+ AMC1_TX3- AMC1_RX3+ AMC1_RX3- AMC3_TX3+ AMC3_TX3- 10 SAS-in AMC2_TX3+ AMC2_TX3- AMC2_RX3+ AMC2_RX3- AMC3_RX3+ AMC3_RX3-

ATCA Receptacle view

Page 124 of the Emerson ATCA-S201 user manual — 10.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignments
Page 124 · click to enlarge
Page 124

Table 50 Connector J32, Management infrastructure signal descriptions SAS-out These signal pairs connect to the SAS controller (LSI-1068) on ATCA-S201, ports 4, 5, 6 and 7. SAS-in These signal pairs route to the Port3 of the AMC slots, sites 0, 1, 2 and 3 LAN0_MDIOxx GbE Management port. 10/100/1000BaseT signals. These signals route to a transceiver owned by the Freescale PowerPC device. LAN0_CTV 10/100/1000BaseT transformer Center Tap signal, which could be used to terminate center tap of transformers, if they are placed on RTM. This signal is applicable if Ethernet PHY is located on ATCA blade, while GE transformers are located on RTM. LEDACT# LAN 0 (Management) activity indicator signal for LED (active low)

LEDLINK# LAN 0 (Management) LINK indicator signal for LED (active low) UART_ RS232 Serial Signals, transmit, receive, clear to send, request to send, data terminal ready, data set ready. These signals route to the Freescale PowerPC device.

10.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignments

The ATCA-S201 J33 connector pin assignments and descriptions appear below.

Table 51 Connector J33, PCIe and Miscellaneous RTM Pin Assignments Row# Interface A B C D E F 1 PCIe PETX0+ PETX0- PERX0+ PERX0- FCLKA+ FCLKA- 2 PCIe PETX1+ PETX1- PERX1+ PERX1- NC NC 3 PCIe PETX2+ PETX2- PERX2+ PERX2- NC NC 4 PCIe PETX3+ PETX3- PERX3+ PERX3- NC NC 5 PCIe PETX4+ PETX4- PERX4+ PERX4- NC NC 6 PCIe PETX5+ PETX5- PERX5+ PERX5- JTAG_TCK JTAG_TMS 7 PCIe PETX6+ PETX6- PERX6+ PERX6- JTAG_TRST# JTAG_TDO 8 PCIe PETX7+ PETX7- PERX7+ PERX7- JTAG_TDI PCIRST# 9 Misc NC RTM# PCICFG# 10 Misc. I2C_RST I2C_SCL I2C_SDA NC PS0# ENABLE#

Emerson ATCA-S201 — 10.2.4.2 Connector J33, PCI-Express and Test infrastructure Pin Assignments diagram (page 124)
Fig. 61 · 10.2.4.2 Connector J33, PCI-Express and Test infrast…
Page 125 of the Emerson ATCA-S201 user manual — 10.2.4.3 Connector J30, Power Supply for RTM
Page 125 · click to enlarge
Page 125

Table 52 Connector J33, PCIe and Miscellaneous RTM Signal Descriptions PETx… PCI-Express transmit differential pair signals PERx… PCI-Express receive differential pair signals FCLKA Fabric clock, as defined in AMC.0 specification. Intended to be used for PCI-Express 100MHz spread spectrum clock. This signal can be either terminated or passed through the CREFCLK via jumpers on the RTM403. The ATCA blade provides no spread spectrum support. PCIRST# PCI-Express reset signal (input). The ATCA board may drive a Logic low to reset PCI-Express switch and PCI-Express interfaces that are behind it. RTM# RTM# signal is grounded by the ATCA-S201 to indicate a MMC controller is present (see AMC.0 specification.) The ATCA implementation shall include a 10Kohm pull-up resistor to management power on the ATCA. In this way, an ATCA is able to detect non-intelligent vs. intelligent RTMs. PCICFG# PCI-Express bus configuration signal. It shall be grounded on RTMs that use a single x8 PCI- Express bus and pulled up on the ATCA with 10Kohm resistor to management power. On RTMs that expect two x4 PCI-Express busses this pin will float (not be connected). Two x4 PCI Express busses are intended for RTM implementations that desire to avoid PCI-Express switch in order to reduce latency. The ATCA-S201 asserts logic ground to this signal. PS0# Active low RTM present signal.PS0# is tied to logic GND on the ATCA blade. PS0# (Connector J33) and PS1# (Connector J30) shall be connected through a diode on the ATCA-S201, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted. ENABLE# When low indicates to RTM that it is fully inserted and that MMC can start execution. Logic high shall keep MMC in reset state. This signal shall have a pull-up resistor as indicated in AMC.0 specification. JTAG_xxx These pins provide a functional JTAG port on the P33 connector. The JTAG chain is for mfg testing only and the chain is not intended for RTM use. I2C_xxx This bus allows an RTM to place peripherals on the ATCA serial management bus.

10.2.4.3 Connector J30, Power Supply for RTM

The ATCA-S201 supplies 12 V and the 3.3 V stand-by voltages to an advanced rear transition modules (RTM) via the P30 connector. The P30 connector assignments also include the IPMI-L interface, PS1#. If needed, an advanced RTM will convert the main 12V payload power into 1.2V, 1.5V, 2.5V and 3.3V by using DCDC converters.

The ATCA-S201 is specified to the following maximum power ratings:

Mean power: 25 W Peak power: 26 W Standard deviation of power from mean power: 0.25 W

The ATCA-S201 P30 connector is implemented by using Metral® 89096-xxx from FCI (www.fciconnect.com).

Page 126 of the Emerson ATCA-S201 user manual — 10.2.4.4 Connector J30, RTM Power Pin Assignment
Page 126 · click to enlarge
Page 126

J30ATCA

Emerson ATCA-S201 — J30ATCA diagram (page 126)
Fig. 62

Figure 35 ‘J30’ RTM Power Receptacle

10.2.4.4 Connector J30, RTM Power Pin Assignment

The ATCA-S201 J30 connector pin assignments and descriptions appear below.

Table 53 J30, RTM Power Pin Header Assignment

Row# Interface 1 2 a Pwr Logic_GND Shelf_GND b Pwr Logic_GND +3.3V MP c IPMI IPMI_SCL_L IPMI_SDA_L d Pwr +12V PP +12V PP e Pwr PS1# NC

Table 54 Connector J30, RTM Power Pin Signal Descriptions PS1# Active low RTM present signal. PS1# shall be pulled up to 3.3 V management power on the ATCA blade. PS0# (Connector P33) and PS1# (Connector P30) shall be connected through a diode on the ATCA-S201, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted. IPMI_SCL_L IPMI bus clock signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0specification. IPMI_SDA_L IPMI bus data signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0 specification. 12VPP 12 V payload power, enabled after successful E-keying, as outlined in the AMC.0 specification. RTM must meet requirements posted for payload power in AMC specification. 3.3V_MP 3.3V Management Power. RTM must meet requirements posted for management power in AMC.0 specification. Shelf_GND Frame/Chassis Safety Ground

Logic_GND (Logic 0vdc). Logic Ground- Common return for Management Power Payload Power, reference potential for single ended logic signaling, and shielding for differential pair signals in the AMC Connector.

e d · c b a

Page 127 of the Emerson ATCA-S201 user manual — 10.2.6 SODIMM DDR Module
Page 127 · click to enlarge
Page 127

10.2.5 Power Supply Mezzanine Module

The ATCA-S201 incorporates a power mezzanine module from Artesyn® Technologies which performs DC-DC conversions to produce the various voltages needed by the ATCA carrier, its AMC slots and the advanced rear transition module is installed. The module supplier is.

Pin# Signal Pin# Signal Pin# Signal Pin# Signal 1 -48_A 9 C_CL 17 A2 25 3V3_OUT 2 -48_B 10 HU 18 INTRPT 26 3V3_OUT 3 NC 11 HUHU+OUT 19 A1 27 NC 4 NC 12 HU+IN 20 SCL 28 NC 5 RTN_A 13 ON/OFF- 21 A0 29 12V_OUT 6 RTN_B 14 ON/OFF+ 22 SDA 30 12V_RTN 7 EN_A 15 B_OK# 23 3V3_RTN 31 8 EN_B 16 A_OK# 24 3V3_RTN 32

Emerson ATCA-S201 — 10.2.5 Power Supply Mezzanine Module diagram (page 127)
Fig. 63 · 10.2.5 Power Supply Mezzanine Module

10.2.6 SODIMM DDR Module

The ATCA-S201 incorporates a SODIMM socket which holds the DDR2 memory for the onboard PowerPC® processor.

Page 128 of the Emerson ATCA-S201 user manual — PICMG 3.1
Page 128 · click to enlarge
Page 128

The RTM-ATCA-SXXX is an Advanced Rear transition module (RTM) that features a SAS expander which provides a storage I/O path between the front ATCA board and rear I/O access panel. The front ATCA board connection conforms to the 3-row Advanced RTM standard. Optionally, the module may be populated with up to two (2) SAS, SATA or SSD 2.5” disk drives. .

Users may pair the RTM-ATCA-SXXX with ATCA disk carriers (ATCA-S120) to create in-chassis JBOD. The RTM-ATCA-SXXX may also be used to add more disk capacity to other ATCA carrier products ATCA cards with proper zone-3 connector pin-outs can extend connectivity to connectors on the RTM panel. All rear panel connectors are compatible with commodity off-the-shelf, non- proprietary cables. Standard connectors include a x4 SAS/SATA IB connector and two RJ45 pass-through management ports (RS232 and 1 GbE Ethernet). The RTM-ATCA-SXXX includes a modular management controller (MMC) and conforms to the PICMG 3.1 revision 2 specification.

11.1 Features of the Advanced Rear Transition Module

The RTM-ATCA-SXXX is a 8U (233.35mm) x 80mm single slot Rear Transition Module with very few active silicon components. The prominent attributes include:

One X4 IB-SAS/SATA port (Infiniband style SFF-8470) Accommodates up to two disks (manufacturing assembly option) 1Gb RS232 LAN port (pass through connection to Front ATCA blade) - LED drive logic RS232 Port ((pass through connection to Front ATCA blade) MMC, with hot swap and LED control, FRUID serial EERPORM (note: The FRU ID is not a separate part but rather embedded in the MMC controller.) Temperature sensors Voltage sensors SPI flash memory

11.2 I/O PICMG Standards Compliance

The RTM-ATCA-SXXX is fully compliant with the following PCI Industrial Computer Manufacturers Group (PICMG) specifications:

PICMG 3.1

11.3 I/O Interfaces

The RTM-ATCA-SXXX mates to ATCA carrier blades via zone-3 connectors in a fashion conforming to PICMG 3.0 ATCA specification revision 2. Internally the ATCA- S201 provides connections to “bridge” between zone3 and the RTM faceplate as follows:

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 118

Page 129 of the Emerson ATCA-S201 user manual — 11.3.2 Ethernet Management Port (RJ-45)
Page 129 · click to enlarge
Page 129

Table 55 I/O Ports Available on RTM Faceplate RTM Zone-3 function RTM Faceplate RS232 Console port Port 1 —RJ45

SAS, x4 (3.0GHz) Port 2 — IB SAS connector (SFF-8470)

1Gb Ethernet Management port Port 3 - RJ45 IPMI — to MMC device on RTM NA Power NA

Emerson ATCA-S201 — 11.3.1 External SAS Connector diagram (page 129)
Fig. 64 · 11.3.1 External SAS Connector
Emerson ATCA-S201 — 11.3.1 External SAS Connector diagram (page 129)
Fig. 65 · 11.3.1 External SAS Connector
Emerson ATCA-S201 — 11.3.1 External SAS Connector diagram (page 129)
Fig. 66 · 11.3.1 External SAS Connector

Figure 36, RTM-ATCA-SXXX Functional Interconnect Diagram

11.3.1 External SAS Connector

The RTM-ATCA-SXXX provides a x4 SAS port, implemented with a infiniband Style connector. Depending on RTM factory configuration, this will carry 4 SAS lanes.

11.3.1.1 SAS Cable Length

The RTM-ATCA-SXXX provides can accommodate SAS Cables up to3M in length.

11.3.2 Ethernet Management Port (RJ-45)

An Ethernet management port is provided on the RTM-ATCA-SXXX to facilitate a pass-through communication path to certain ATCA board products. The port uses an RJ-45 connector, with integrated LED for Link (green) and activity (amber). The port auto negotiates to either 10/100/1000BASE-T.

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 119

10BRTM‐ATCA‐SXXX Overview

Page 130 of the Emerson ATCA-S201 user manual — 11.4 LEDs
Page 130 · click to enlarge
Page 130
Emerson ATCA-S201 — 11.3.3 Serial Console Port (RJ-45) diagram (page 130)
Fig. 67 · 11.3.3 Serial Console Port (RJ-45)

Figure 37, Ethernet Management Port

11.3.3 Serial Console Port (RJ-45)

An RS232 serial console port is provided on the RTM-ATCA-SXXX to facilitate a pass- through communication path to certain ATCA board products. The port uses an RJ45 connector.

11.4 LEDs

The following LEDs are located on the face plate of the RTM-ATCA-SXXX.

Table 56 LEDs On RTM Faceplate LED RTM Faceplate On LAN management activity LED Ethernet Activity AMBER

Off No Activity On LAN management LINK LED Ethernet Link GREEN

Off No Link On Management power available to the module and the module can safely be extracted Off The module is operational and is unsafe for extraction Long Blink Delay before module is activated

Hot Swap (HS) BLUE

Short Blink Delay before module is de-activated On Module Fault set by Shelf manager or 12V payload power not detected. Fault or “Out of Service” (OOS) RED

Off No module fault 12V payload power is being supplied to board On 12V payload power is being supplied to board Module Ready (OK) and “in service” GREEN

Off 12V payload power is not detected

Page 131 of the Emerson ATCA-S201 user manual — 11.7 Identification Labels
Page 131 · click to enlarge
Page 131
Emerson ATCA-S201 — 11.5 Software Support diagram (page 131)
Fig. 68 · 11.5 Software Support

Figure 38 RTM-ATCA-SXXX Front Panel LEDs

11.5 Software Support

The RTM-ATCA-SXXX requires no special software to operate. As shipped from the factory, the expander is un-zoned, and configured for table routing.

11.6 Products Supported by this Manual

The information in this manual applies to the following products:

RTM-ATCA-SXXX-0 RTM-ATCA-SXXX-2 RTM-ATCA-SXXX-2-300

Emerson ATCA-S201 — RTM-ATCA-SXXX-0 RTM-ATCA-SXXX-2 RTM-ATCA-SXXX-2-300 diagram (page 131)
Fig. 69

Figure 39. RTM-ATCA-SXXX Top View (Two Disk Drives)

11.7 Identification Labels

At manufacturing time, several labels are affixed to the RTM-ATCA-SXXX as shown below. For proper identification of the RTM, use these barcode labels to accurately

Page 132 of the Emerson ATCA-S201 user manual — RTM-ATCA-SXXX-0
Page 132 · click to enlarge
Page 132

determine the module identity. The barcode labels provide the following information:

Table 57 RTM-ATCA-SXXX Identification Labels

Label 1Final assembly P/N

For Internal Use Only

Label 2Sub-Assembly P/N For Internal Use Only
Label 3Serial number (S/N) S/N Format :AAA = Assembly Number (401)

L =Location of manufacturer (S)

Y = Calendar year of manufacturer (2008 = 8, 2010=A)

MM = Calendar month of manufacturer (March = 03)

SSSS = Sequence number (reset each month) (1234)

Label 4Part Numbers

This label contains 2 numbers:

Top = Internal Part Number

Example0106828G01A

Bottom = Ordering Part Number

RTM-ATCA-SXXX-0

Label Description

Page 133 of the Emerson ATCA-S201 user manual — 11 RTM-ATCA-SXXX Overview
Page 133 · click to enlarge
Page 133
Emerson ATCA-S201 — 11 RTM-ATCA-SXXX Overview diagram (page 133)
Fig. 70 · 11 RTM-ATCA-SXXX Overview

Figure 40 RTM-ATCA-SXXX Diagram Showing Identification Label Locations

Page 134 of the Emerson ATCA-S201 user manual — 0.55 A (6.6 W) 2.05 A (24.6 W)
Page 134 · click to enlarge
Page 134

12 RTM-ATCA-SXXX Installation

This chapter contains the procedures for installing and removing the RTM-ATCA-SXXX.

12.1 Installation and Removal of the Rear Transition Module

The RTM-ATCA-SXXX can be installed into an ATCA shelf (chassis) with a midplane made for front and rear board installations. The module must be installed in the slot directly behind the host ATCA node board. These back-to-back slots have common pins to enable passing of signals via the Zone-3 connector complex.

12.2 Important Information about Your Chassis

Before installing the rear transition module, verify the module’s part number to ensure that the correct rear transition module is being installed into the system. For information on identifying the rear transition module, see Section11.6.

12.2.1 Safety Statement

The RTM-ATCA-SXXX is designed to comply with UL60950-1, and is intended to be used with similarly tested ATCA products that have a user’s guide detailing user installation of module accessories.

12.2.2 Observe Maximum Module Current Requirements

There are several manufacturing options for the RTM. The diskless version of the RTM requires no power from the front ATCA node board, but may draw up to 200mA from the 3.3 V management power source. Be sure to validate that the host chassis can supply the RTM slot with these maximum current requirements.

Table 58 Max RTM Module Current Requirements

Module Current RTM-ATCA- SXXX-0 (No Disk)

RTM-ATCA-SXXX-2 (Two disk version)

+12 V (spin up < 100 sec)

0.55 A(6.6W) 2.05 A (25 W) (staggered spin-up) +12 V normal operating

0.55 A (6.6 W) 2.05 A (24.6 W)

+12 V (idle) 0.55 A (6.6 W) 1.55 A (18.6 W) OFF STATE LESS THAN 0.4 W LESS THAN 0.4 W

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 124

Page 135 of the Emerson ATCA-S201 user manual — 12.3.2 Watch for Bent Pins or Other Damage
Page 135 · click to enlarge
Page 135

Module Current RTM-ATCA- SXXX (No Disk)

RTM-ATCA-SXXX-2 (Two disk version)

+12 V (spin up < 100 sec)

0.55 A(6.6W) 2.05 A (25 W) (staggered spin-up) +12 V normal operating

0.55 A (6.6 W) 2.05 A (24.6 W)

+12 V (idle) 0.55 A (6.6 W) 1.55 A (18.6 W) OFF STATE LESS THAN 0.4 W LESS THAN 0.4 W

12.3 Before You Install Or Remove The RTM

Boards may be damaged if improperly installed or handled. Please read and follow the guidelines in this section to protect your equipment.

12.3.1 Observe ESD Precautions

Emerson strongly recommends that you use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to electrostatic discharge (ESD). After removing the component from its protective wrapper or from the system, place the component flat on a grounded, static-free surface (and, in the case of a board, component side up). Do not slide the component over any surface.

If an ESD station is not available, you can avoid damage resulting from ESD by wearing an antistatic wrist strap (available at electronics stores) that is attached to an active electrical ground. Note that a system chassis may not be grounded if it is unplugged.

12.3.2 Watch for Bent Pins or Other Damage

Bent pins or loose components can cause damage to the board, the backplane, or other system components. Carefully inspect your board and the backplane for both pin and component integrity before installation. Our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving our factory. Bent pins caused by improper installation or by boards with damaged connectors could void the warranty for the backplane or boards.

If a system contains one or more crushed pins, power off the system and contact your local sales representative to schedule delivery of a replacement chassis assembly.

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 125

RTM-ATCA-SXXX Installation

Page 136 of the Emerson ATCA-S201 user manual — 12.6 Installing the Advanced Rear Transition Module
Page 136 · click to enlarge
Page 136

12.4 Use Caution When Installing or Removing RTM

When first installing boards in an empty chassis or onto a carrier card, we recommend that you start at the left of the card cage and work to the right. When inserting or removing a board in a slot adjacent to other boards, use extra caution to avoid damage to the pins and components located on the primary or secondary sides of the boards.

12.4.1 Preserve EMI Compliance

To preserve compliance with applicable standards and regulations for electromagnetic interference (EMI), during operation all front and rear openings on the chassis or board faceplates must be filled with an appropriate card or covered with a filler panel. If the EMI barrier is open, devices may cause or be susceptible to excessive interference.

12.4.2 Understand Hot Swap

Your RTM is electrically designed for hot swap within a fully powered chassis. To facilitate hot swap, there is a blue LED on the rear faceplate. This LED is under software control.

If your system is using software that provides full hot swap capabilities, the software will illuminate the blue hot swap LED on the rear faceplate when software has stopped and it is safe to remove the advanced rear transition module.

If your system does not have hot swap-aware software running, behavior of the blue LED is indeterminate. In this case, you may need to manually shut down applications or operating systems running on the board prior to board removal, even if the blue LED is lit.

Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.

12.5 Verify Slot Usage

Prevent possible damage to module components by verifying the proper slot usage for your configuration.

12.6 Installing the Advanced Rear Transition Module

This section describes a recommended procedure for installing the RTM module in a chassis.

Before you install your module, please read all cautions, warnings, and instructions presented in this section.

RTM‐ATCA‐SXXX Installation

Page 137 of the Emerson ATCA-S201 user manual — 12.4 Use Caution When Installing or Removing RTM
Page 137 · click to enlarge
Page 137

Handling modules and peripherals can result in static damage. Use a grounded wrist strap, static-dissipating work surface, and antistatic containers when handling and storing components.

Insert the board by holding the Module Handles–do not exert unnecessary pressure on the faceplate.

Hot swap compliant modules may be installed while the system is powered on. If a module is not hot swap compliant, you should remove power to the slot or system before installing the module.

5. Verify that you have taken the necessary antistatic precautions.
6. Go to the back of the system and choose an appropriate slot for the rear transition module. Rear transition modules must be installed in-line behind the accompanying node board. For example, if the accompanying node board is going to be installed in slot 3, its rear transition module must be installed at the back of the system in slot 3.
7. Remove the slot filler panel from the selected node board slot, if necessary.
8. Prepare the module by loosening the locking screws and opening the injector/ejector latch at the top of the module as shown in the figure below.
Emerson ATCA-S201 — 12.4 Use Caution When Installing or Removing RTM diagram (page 137)
Fig. 71 · 12.4 Use Caution When Installing or Removing RTM

Figure 41 Injector / Ejector Latch and Locking Screw

9. Carefully align the edges of the module with the guides in the appropriate slot. It might be helpful to look into the enclosure to verify correct alignment of the rails in the guides. Align the edges of the module with the card cage rail guides in the appropriate slot.
10. Taking care to keep the module aligned in the guides, apply equal and steady pressure and slide the module in until the injector/ejector mechanism engages the retention bars.

RTM‐ATCA‐SXXX Installation

Page 138 of the Emerson ATCA-S201 user manual — 12.8 Verifying the Hardware Installation
Page 138 · click to enlarge
Page 138
11. Position your thumbs at the top and bottom of the RTM; simultaneously push in the module and rotate the injector/ejector mechanisms inward to their closed position to seat and secure RTM. DO NOT FORCE THE BOARD INTO THE SLOT.
12. Tighten the two module retention screws to secure the module into the shelf.
13. Power on the system, if necessary. Refer to your system manual for instructions on correctly powering on the system. Once power is applied to the chassis, the internal MMC controller runs a self-test that runs for approximately 10 seconds. Upon a successful power up self-test, the blue hot swap LED will blink and then turn off, indicating that the module has been placed in operation.

12.7 Removing the Advanced Rear Transition Module

The RTM-ATCA-SXXX is hot-swappable and can be removed from the chassis without powering down its associated node board. This section describes a recommended procedure for removing a board module from a chassis.

Before you remove your module, please read all cautions, warnings, and instructions presented in this section. Hot swap compliant modules may be removed while the system is powered on. If the chassis is not hot swap compliant, you should remove power to the slot or system before removing the module.

To remove a rear transition module, follow these steps:

14. Loosen the locking screws on the rear transition module.
15. Rotate the top ejector handle to the half way (HW) position. Do not remove the module immediately.
16. If your host module running hot swap-aware software, the action of rotating the ejector lever will start the shutdown process on the board. The software will slowly blink the blue hot swap LED indicating the module is in the process of being de-activated.
17. Once the module has been de-activated, the Blue LED will illuminate steady. Once this is done you can extract the module by pulling on the module handle. Note: Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.
18. If your board or system is not running hot swap-aware software, the blue LED may illuminate without regard to software processes still running on the board. Be sure to manually shut down applications or operating systems running on the board prior to board removal.
19. Carefully pull the module from the chassis.
20. If the card slot is to remain empty, install a filler panel in the slot.

12.8 Verifying the Hardware Installation

This section provides information to verify the installation of the RTM-ATCA-SXXX. Visually inspect the module power LED on the RTM panel. Refer to Figure 38 RTM- ATCA-SXXX Front Panel LEDs.

RTM‐ATCA‐SXXX Installation

Page 139 of the Emerson ATCA-S201 user manual — 13.1.3 Environmental Specifications and Compliance
Page 139 · click to enlarge
Page 139

13 RTM-ATCA-SXXX Mechanical and Connector Information

This chapter provides the specifications and connector pin outs for the RTM-ATCA-SXXX.

13.1 Specifications for the RTM-ATCA-SXXX

This section provides mechanical, electrical, environmental, and other relevant information.

13.1.1 Physical Dimensions

The RTM-ATCA-SXXX is an 8U (233.35 mm) height board with 80 mm in depth for standard applications. It complies with IEEE 1101.11 mechanical standards, as required by the PICMG 2.0 Revision 3.0 specification. The RTM-ATCA-SXXX is keyed to conform to the PICMG 2.10, Keying of ATCA Boards and Backplanes specification.

13.1.2 Power Requirements

There are several manufacturing options for the RTM. Be sure to validate the host chassis, can supply the RTM slot with these maximum current requirements.

Table 59 Max RTM Module Current Requirements

Module Current ATCA-S201-0 (No Disk)

ATCA-S201-2 (Two disk version)

+12V (spin up < 100 sec)

0.55A(6.6W) 2.05A (25W) (staggered spin-up) +12v normal operating

0.55A (6.6W) 2.05A (24.6W)

+12v (idle) 0.55A (6.6W) 1.55A (18.6W) OFF STATE LESS THAN 0.4W LESS THAN 0.4W

13.1.3 Environmental Specifications and Compliance

The environmental specifications for the RTM-ATCA-SXXX assembly are presented in the table below.

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 129

Page 140 of the Emerson ATCA-S201 user manual — 13.1.5 Electromagnetic Compliance
Page 140 · click to enlarge
Page 140

RTM-ATCA-SXXX Mechanical and Connector Information

Table 60 Environmental Specifications for the ATCA-S201 SPECIFICATION VALUE Operating Temperature (airflow 3.1 CFM) 0°C ~ 55 °C Storage Temperature -40 °C ~ 85 °C Operating Temperature Gradient 11 °C /H (max) Storage Temperature Gradient 20 °C /H (max) Shipping Temperature Gradient 20 °C /H (max) *1 Operating Humidity 8 % ~ 80 % Storage Humidity 5 % ~ 95 % Shipping Humidity 5 % ~ 95 % *1 Wet bulb Maximum Temperature 27 °C Condensation No condensation Atmospheric Pressure and Altitude Operating: 0 ~ 3,000 m Shipping: 0 ~ 12,000 m Operating Shock

See PICMG 3.0 specification, Regulatory guidelines.

Operating Vibration See PICMG 3.0 specification, Regulatory guidelines. RoHS 6 of 6 compliant.

13.1.4 NEBS Compliance

NEBS certifications are performed by integrator at a system level (chassis, ATCA, AMC shelf managers etc). The RTM module will not preclude the system form passing NEBS.

13.1.5 Electromagnetic Compliance

The board is designed and implemented so as to minimize electromagnetic emissions, susceptibility, and the effects of electrostatic discharge. The board carries the following certifications:

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 130

Page 141 of the Emerson ATCA-S201 user manual — 13.2 Connectors and Pin Assignments
Page 141 · click to enlarge
Page 141

RTM‐ATCA‐SXXX Mechanical and Connector Information

Table 61 EMC Emission Compliancy Description Description US: FCC 47 CFR Part 15 Class A Yes, Class A emissions requirements (USA) Canada: ICES 003 Class A Yes Class A Digital Apparatus emissions (Canada) Japan: VCCI Class A Yes Class A ITE emissions requirements (Japan) Europe Commercial: EN 55022:1994 Class A Yes, Class A ITE emissions requirements (EU)

Europe CommercialEN 55024:1998 Class A Immunity for ITE equipment
Europe CommercialEN 61000-42,3,5,6,8,11: 2001 EMC Electrostatic discharge immunity
Europe CommercialEN 61000-4-4: 2000 (Limits for harmonic current emissions) Yes

Europe Commercial: EN 61000-3-2,3 Yes, Limits for harmonic current emissions Europe Telecom Carrier: EN 300-386 v1.3.3 April 2005

Requirements for Telecom Network Equipment — Non-Telco Centers Europe CE Mark Yes Australia: AS/NZS 3548 C-Tick Yes, Class A ITE emissions requirements (Australia) South Korea: MIC Taiwan: BSMI

13.2 Connectors and Pin Assignments

This section provides position and pin-out details of all connectors available on the RTM-ATCA-SXXX.

Page 142 of the Emerson ATCA-S201 user manual — S1 S15
Page 142 · click to enlarge
Page 142

RTM‐ATCA‐SXXX Mechanical and Connector Information

Table 62 Connector Port Identification and Location 1 Serial console port 4 Zone 3 Connector 2 SAS Connector 5 Power connector 3 10/100/1000 Mb management port 6 RTM alignment pin

Emerson ATCA-S201 — 13.2.1 SAS Connector Port diagram (page 142)
Fig. 72 · 13.2.1 SAS Connector Port

Figure 42 RTM-ATCA-SXXX Connectors

13.2.1 SAS Connector Port

Port 3 provides an infiniband (IB) SAS connector, SFF-8470. The port is wired as pass-through to the front ATCA carrier via the J32/P32 Zone-3 connector. This receptacle features jack screws to mechanically secure the external cable. A cable can be ordered from Emerson.

Figure 43. RTM-ATCA-SXXX Front Panel SAS Connector Pin-Out Diagram

S2 S16

Top

Emerson ATCA-S201 — S2 S16 diagram (page 142)
Fig. 73

S1 S15

Page 143 of the Emerson ATCA-S201 user manual — SAS_TX0S15
Page 143 · click to enlarge
Page 143

RTM‐ATCA‐SXXX Mechanical and Connector Information

Table 63. RTM-ATCA-SXXX Front Panel SAS Connector Pin Assignments

Connecto r Pin Description SAS_RX0 + S1 SAS_RX0- S2

SAS Lane 0, Rx Differential Pair, Drives ATCA Zone 3 connector (P32) SAS_RX1 + S3 SAS_RX1- S4

SAS Lane 1, Rx Differential Pair, Drives ATCA Zone 3 connector (P32) SAS_RX2 + S5 SAS_RX2- S6

SAS Lane 2, Rx Differential Pair, Drives ATCA Zone 3 connector (P32) SAS_RX3 + S7 SAS_RX3- S8

SAS Lane 3, Rx Differential Pair, Drives ATCA Zone 3 connector (P32)

SAS_TX3S9 SAS_TX3+ S10

SAS Lane 3, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)

SAS_TX2S11 SAS_TX2+ S12

SAS Lane 2, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)

SAS_TX1S13 SAS_TX1+ S14

SAS Lane 1, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)

SAS Lane 0, Tx Differential Pair, Drives ATCA Zone 3 connector (P32)

SAS_TX0S15

SAS_TX0+ S16

13.2.2 10/100/1000 Mb Management Port

The RTM-ATCA-SXXX provides a 1 GbE management port on the faceplate via RJ45 jack (port 3). The port is wired as pass-through to the front ATCA carrier via the J32/P32 Zone-3 connector

Table 64 10/100/1000 Management Port Connector Pin Assignments Pin Signal Name Pin Signal Name 1 LAN0_A+ 5 LAN0_C- 2 LAN0_A- 6 LAN0_B- 3 LAN0_B+ 7 LAN0_D+ 4 LAN0_C+ 8 LAN0_D-

Figure 44 10/100/1000 Mb Management Port Pin Location Diagram

Signal

Page 144 of the Emerson ATCA-S201 user manual — 13.2.4 Zone 3 Connectors
Page 144 · click to enlarge
Page 144

RTM‐ATCA‐SXXX Mechanical and Connector Information

13.2.3 Serial Console Management Port

Port 4 is a low-profile RJ-45 connector jack that provides RS232 signaling. The port is wired as pass-through to the front ATCA carrier via the J32/P32 Zone-3 connector

Table 65 Serial Console Management Port Connector Pin Assignments Pin Signal Name Pin Signal Name 1 RTS 5 GND 2 DTR 6 RXD 3 TXD 7 DSR 4 GND 8 CTS

Emerson ATCA-S201 — 13.2.3 Serial Console Management Port diagram (page 144)
Fig. 74 · 13.2.3 Serial Console Management Port

Figure 45 Serial Console Management Port Pin Location Diagram

13.2.4 Zone 3 Connectors

The RTM-ATCA-SXXX routes several I/O signals to the Zone-3 connector complex consisting of connectors J30, J32 and J3. These connectors enable expansion using rear transition modules (RTM) whose ‘J’ connectors mirror the ‘P’ connectors located on the carrier module. All of these connectors utilize a 3-pin per column type available from Tyco electronics (http://www.tycoelectronics.com), part number 6469081-1

Page 145 of the Emerson ATCA-S201 user manual — 13.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments
Page 145 · click to enlarge
Page 145

RTM‐ATCA‐SXXX Mechanical and Connector Information

Emerson ATCA-S201 — 13.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments diagram (page 145)
Fig. 75 · 13.2.4.1 Connector P32, Storage and Management Infra…

Figure 46 Zone 3, Connector Port Pin Location Diagram

13.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments

The RTM-ATCA-SXXX P32 connector pin assignments and descriptions appear below.

Table 66 Connector P32, Management Infrastructure Pin Assignments Row# Interface A B C D E F

Emerson ATCA-S201 — 13.2.4.1 Connector P32, Storage and Management Infrastructure Pin Assignments diagram (page 145)
Fig. 76 · 13.2.4.1 Connector P32, Storage and Management Infra…

3 SAS SAS_TX1+ SAS_TX1- SAS_RX1+ SAS_RX1- UART_TXD0 UART_RXD0 4 SAS SAS_TX2+ SAS_TX2- SAS_RX2+ SAS_RX2- NC UART_CTS0# 5 SAS SAS_TX3+ SAS_TX3- SAS_RX3+ SAS_RX3- NC NC 6 LAN0 LAN0_MDIO0+ LAN0_MDIO0- LAN0_CTV LAN0_CTV LAN0_MDIO1+ LAN0_MDIO1- 7 LAN0 LAN0_MDIO2+ LAN0_MDIO2- LAN0_LEDACT# LAN0_LEDLNK# LAN0_MDIO3+ LAN0_MDIO3-

9 SAS SAS_TX5+ SAS_TX5- SAS_RX5+ SAS_RX5- SAS_TX7+ SAS_TX7- 10 SAS SAS_TX6+ SAS_TX6- SAS_RX6+ SAS_RX6- SAS_RX7+ SAS_RX7-

Page 146 of the Emerson ATCA-S201 user manual — 13.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignments
Page 146 · click to enlarge
Page 146

RTM‐ATCA‐SXXX Mechanical and Connector Information

Table 67 Connector J32, Management Infrastructure Signal Descriptions SAS ports 4-7 A manufacturing option exists for these signals. These pins are either No-connect, or These transceiver pairs will connect port2 of the AMC front slots. (Port 4 routes to site 0) SAS ports 0-3 These transceiver pairs will connect port3 of the AMC front slots (Port 0 routes to site 0) LAN0_MDIOxx GbE Management port. 10/100/1000BaseT signals. These signals route to a transceiver owned by the Freescale PowerPC device. LAN0_CTV 10/100/1000BaseT transformer Center Tap signal, which could be used to terminate center tap of transformers, if they are placed on RTM. This signal is applicable if Ethernet PHY is located on ATCA blade, while GE transformers are located on RTM. LEDACT# LAN 0 (Management) activity indicator signal for LED (active low) LEDLINK# LAN 0 (Management) LINK indicator signal for LED (active low) UART_ RS232 Serial Signals, transmit, receive, clear to send, request to send, data terminal ready, data set ready. These signals route to the Freescale PowerPC device.

13.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignments

The RTM-ATCA-SXXX, J33 connector pin assignments and descriptions appear below.

Table 68 Connector J33, Miscellaneous RTM Pin Assignments Row# Interface A B C D E F 1 NC 2 NC 3 NC 4 NC 5 NC 6 NC 7 NC 8 NC 9 NC 10 Misc. NC PS0# ENABLE#

Emerson ATCA-S201 — 13.2.4.2 Connector J33, PCI-Express and Test Infrastructure Pin Assignments diagram (page 146)
Fig. 77 · 13.2.4.2 Connector J33, PCI-Express and Test Infrast…
Page 147 of the Emerson ATCA-S201 user manual — 13.2.4.4 Connector J30, RTM Power Pin Assignment
Page 147 · click to enlarge
Page 147

RTM‐ATCA‐SXXX Mechanical and Connector Information

Table 69 Connector J33, Miscellaneous RTM Signal Descriptions PS0# Active low RTM present signal.PS0# is tied to logic GND on the ATCA blade. PS0# (Connector J33) and PS1# (Connector J30) shall be connected through a diode on the RTM, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted ENABLE# When low indicates to RTM that it is fully inserted and that MMC can start execution. Logic high shall keep MMC in reset state. This signal shall have a pull-up resistor as indicated in AMC.0 specification.

13.2.4.3 Connector J30, Power Supply for Advanced RTM

The RTM-ATCA-SXXX supplies 12V and the 3.3V stand-by voltages to an Advanced rear transition modules (RTM) via the P30 connector. The P30 connector assignments also include the IPMI-L interface, PS1#. If needed, an Advanced RTM will convert the main 12V payload power into 1.2V, 1.5V, 2.5V and 3.3V by using DCDC converters.

The RTM-ATCA-SXXX P30 connector is implemented with the Metral® 89096-xxx from FCI (www.fciconnect.com).

J30ATCA

Emerson ATCA-S201 — J30ATCA diagram (page 147)
Fig. 78

Figure 47 ‘J30’ RTM Power Receptacle

13.2.4.4 Connector J30, RTM Power Pin Assignment

The RTM-ATCA-SXXX J30 connector pin assignments and descriptions appear below.

Table 70 J30, RTM Power Pin Header Assignment Row# Interface 1 2 e Pwr PS1# NC d Pwr +12V PP +12V PP c IPMI IPMI_SCL_L IPMI_SDA_L b Pwr Logic_GND +3.3V MP a Pwr Logic_GND Shelf_GND

e d · c b a

Page 148 of the Emerson ATCA-S201 user manual — 13.2.4.3 Connector J30, Power Supply for Advanced RTM
Page 148 · click to enlarge
Page 148

RTM‐ATCA‐SXXX Mechanical and Connector Information

Table 71 Connector J30, RTM Power Pin Signal Descriptions PS1# Active low RTM present signal. PS1# shall be pulled up to 3.3V Management Power on the ATCA blade. PS0# (Connector P33) and PS1# (Connector P30) shall be connected through a diode on the RTM, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted IPMI_SCL_L IPMI bus clock signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0specification. IPMI_SDA_L IPMI bus data signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0 specification. 12VPP 12V Payload Power, enabled after successful E-keying, as outlined in the AMC.0 specification. RTM must meet requirements posted for payload power in AMC specification 3.3V_MP 3.3V Management Power. RTM must meet requirements posted for management power in AMC.0 specification. Shelf_GND Frame/Chassis Safety Ground

Logic_GND (Logic 0vdc). Logic Ground- Common return for Management Power Payload Power, reference potential for single ended logic signaling, and shielding for differential pair signals in the AMC Connector.

Page 149 of the Emerson ATCA-S201 user manual — 14.2 Sensor data records
Page 149 · click to enlarge
Page 149

14 IPMI Functions List

The ATCA-S201 module supports the intelligent platform management interface (IPMI) version 1.5. This system is used to collect status information from on on-board sensors as well as sensors installed on AMC or RTM modules. Collected information items include:

Hot swap communication with the shelf manager Inlet air temperatures Voltage monitoring Electronic Keying as described in the AMC.0 specification FRU information Drives blue LED indicators for hot swap, OOS (out of service) Drives green LED for module “OK”

The RTM-ATCA-SXXX module includes an MMC device for reporting status information to the ATCA blade. This MMC utilizes an Intelligent Platform Management Interface (IPMI) which will communicate with the ATCA. This MMC controls and monitors the following:

Hot Swap communication with the shelf manager Inlet air temperatures Voltage monitoring Electronic Keying as described in the AMC.0 specification FRU information Drives “blue” LED indicators for Hot Swap. OOS (out of service), Drives “green LED for module “OK”

14.1 IPMI and Management Controller (IPMC)

The design features an IPMI controller consisting of a 16-bit microcontroller, flash and SRAM. The microcontroller uses I2C interface to communicate the shelf management controller (ShMC), sensors, and MMC devices on AMC modules and the RTM if installed.

Support hot-swap operation as defined for AMC modules in PICMG AMC.0 specification “Fail-safe flash update” - if interrupted at anytime, the MMC firmware is still able to respond and re-flash.

14.2 Sensor data records

The MMC monitors the status of the module and provides this data so it can be read by the shelf manager. Below are the SDRs that the ATCA-S201 and the RTM-ATCA- SXXX modules create.

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 139

Page 150 of the Emerson ATCA-S201 user manual — 14 IPMI Functions List
Page 150 · click to enlarge
Page 150

Table 72. ATCA-S201 Sensor Data Records

Emerson ATCA-S201 — 14 IPMI Functions List diagram (page 150)
Fig. 79 · 14 IPMI Functions List

Sensor UNR UC UNC LNC LC LNR ID String

1.0V 1.16 1.13 1.10 0.90 0.87 0.84 +1.0V 1.1V 1.27 1.24 1.21 0.99 0.99 0.91 +1.1V 1.2V 1.40 1.36 1.32 1.08 1.04 1.00 +1.2V 1.5V 1.75 1.70 1.65 1.35 1.30 1.25 +1.5V 1.8V 2.05 2.00 1.95 1.65 1.60 1.55 +1.8V 2.5V 2.90 2.80 2.70 2.30 2.20 2.10 +2.5V 3.3V 3.60 3.55 3.50 3.10 3.00 2.0 +3.3V

AMC exit Temp Zone-3 Exit 80 90 100 N/A N/A N/A Zone3-Exit Inlet Temp 60 70 80 N/A N/A N/A Inlet Temp

AMC Exit Temp 80 90 100 N/A N/A N/A

Table 73. RTM-ATCA-SXXX Sensor Data Records

Emerson ATCA-S201 — 14 IPMI Functions List diagram (page 150)
Fig. 80 · 14 IPMI Functions List

Sensor UNR UC UNC LNC LC LNR ID String 3.3V 3.60 3.50 3.45 3.15 3.10 3.00 +3.3V 5.0V 5.50 5.35 5.25 4.75 4.65 4.5 +5V 12V 13.60 13.40 13.00 11.00 10.60 10.400 +12V Board Temp (LM75) 70 60 50 N/A N/A N/A Board Temp Inlet Temp (LM60) 70 60 50 N/A N/A N/A Inlet Temp

The ATCA-S201 and the RTM-ATCA-SXXX include the standard FRU data records per the IPMI Platform Management FRU Information Storage Definition, Board Info Area. The ATCA-S201 and the RTM-ATCA-SXXX include additional FRU records as defined in the PICMG 2.9 specification.

Table 74 ATCA-S201 Example FRU Data Records

Board Information ATCA-S201 Version 1 Language Code EN (English) MFG date.time See note *1 Manufacturer Emerson Product Name ATCA-S201 Serial Number 100LYMMssss (See note *2) Part Number 0106826G01A

Emerson ATCA-S201 — 14 IPMI Functions List diagram (page 150)
Fig. 81 · 14 IPMI Functions List

*1. Manufacturing time is defined as 'minutes since 1/1/96' in the IPMI FRU spec.

*2. Serial Number format102LYMSSSS

AAA = Assembly Number (102)

L =Location of manufacturer

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 14-1

Page 151 of the Emerson ATCA-S201 user manual — 14.2.1 RTM e-Keying Port Assignments
Page 151 · click to enlarge
Page 151

Y = Calendar year of manufacturer (2008 = 8, 2010 = 0)

MM = Calendar month of manufacturer (March = 03)

ssss = Sequence number (reset each month) (1234)

Table 75 RTM-ATCA-SXXX Example FRU Data Records

Board Information RTM-ATCA-SXXX Version 1 Language Code EN (English) MFG date.time See note *1 Manufacturer Emerson Product Name RTM-ATCA-SXXX Serial Number AAALYMMssss (See note *2) Part Number 0106828G01A

Emerson ATCA-S201 — 14.2.1 RTM e-Keying Port Assignments diagram (page 151)
Fig. 82 · 14.2.1 RTM e-Keying Port Assignments

*1. Manufacturing time is defined as 'minutes since 1/1/96' in the IPMI FRU spec.

*2. Serial Number formatAAALYMMssss

AAA = 401 part code (denotes RTM-ATCA-SXXX)

L =Location of manufacturer (S)

Y = Calendar year of manufacturer (2008 = 8)

MM = Calendar month of manufacturer (March = 03)

SSSS = Sequence number (reset each month) (1234)

14.2.1 RTM e-Keying Port Assignments

Port # Port Name Link type Link type extension

Emerson ATCA-S201 — 14.2.1 RTM e-Keying Port Assignments diagram (page 151)
Fig. 83 · 14.2.1 RTM e-Keying Port Assignments

1 unused 2 unused 2 PCIe Lane0 AMC.1 PCI Express type 8 0, Gen1 J33 A1,B1, C1, D1 3 PCIe Lane1 AMC.1 PCI Express type 8 0, Gen1 J33 A2,B2, C2, D2 4 PCIe Lane2 AMC.1 PCI Express type 8 0, Gen1 J33 A3,B3, C3, D3 5 PCIe Lane3 AMC.1 PCI Express type 8 0, Gen1 J33 A4,B4, C4, D4 6 PCIe Lane4 AMC.1 PCI Express type 8 0, Gen1 J33 A5,B5, C5, D5 7 PCIe Lane5 AMC.1 PCI Express type 8 0, Gen1 J33 A6,B6, C6, D6 8 PCIe Lane6 AMC.1 PCI Express type 8 0, Gen1 J33 A7,B7, C7, D7 9 PCIe Lane7 AMC.1 PCI Express type 8 0, Gen1 J33 A8,B8, C8, D8

10 SAS_0 AMC.3 Storage signaling J32-A2, B2, C2, D2

11 SAS_1 AMC.3 Storage signaling J32-A3, B3, C3, D3

IPMI Functions List

Page 152 of the Emerson ATCA-S201 user manual — 14 AMC1_EO_12 J31 C1,D1, E1, F1
Page 152 · click to enlarge
Page 152

12 SAS_2 AMC.3 Storage signaling J32-A4, B4, C4, D4

13 SAS_3 AMC.3 Storage signaling J32-A5, B5, C5, D5

14 AMC1_EO_12 J31 C1,D1, E1, F1

15 AMC1_EO_13 J31 A1,B1, E2, F2

16 AMC1_EO_14 J31 A2,B2, C2, D2

17 AMC1_EO_15 J31 C3,D3, E3, F3

18 AMC1_EO_16 J31 A3,B3, E4, F4

19 AMC1_EO_17 J31 A4, B4, C4, D4

20 AMC1_EO_18 J31 C5, D5, E5, F5

21 AMC1_EO_19 J31 A5, B5, E6, F6

14.3 Supported IPMI Commands

The MMC communicates with the carrier controller through the local IPMB-L bus of the carrier and responds to all mandatory commands for AMC Module Management Controllers (as defined in the RTM Specification), as well as some optional ones.

IPMI Functions List · 22-31 unused

Page 153 of the Emerson ATCA-S201 user manual — 14.3 Supported IPMI Commands
Page 153 · click to enlarge
Page 153

Table 76 Supported IPMI Commands

IPMI/PICMG/A MC Spec NetFn CMD MMC Req IPM Device “Global” Commands Get Device ID 17.1 App 01h Mandatory Broadcast “Get Device ID” 17.9 App 01h Mandatory Messaging Commands Send Message 18.7 App 34h Optional Event Commands Platform Event 23.3 S/E 02h Mandatory Sensor Device Commands Get Device SDR Info 29.2 S/E 20h Mandatory Get Device SDR 29.3 S/E 21h Mandatory Reserve Device SDR Repository 29.4 S/E 22h Mandatory Get Sensor Reading Factors 29.5 S/E 23h Optional Set Sensor Hysteresis 29.6 S/E 24h Optional Get Sensor Hysteresis 29.7 S/E 25h Optional Set Sensor Threshold 29.8 S/E 26h Optional Get Sensor Threshold 29.9 S/E 27h Optional Set Sensor Event Enable 29.10 S/E 28h Optional Get Sensor Event Enable 29.11 S/E 29h Optional Rearm Sensor Events 29.12 S/E 2Ah Optional Get Sensor Event Status 29.13 S/E 2Bh Optional Get Sensor Reading 29.14 S/E 2Dh Mandatory FRU Device Commands Get FRU Inventory Area Info 28.1 Storage 10h Mandatory Read FRU Data 28.2 Storage 11h Mandatory Write FRU Data 28.3 Storage 12h Mandatory ATCA™ Commands Get PICMG Properties 3-9 PICMG 00h Mandatory FRU Control 3-22 PICMG 04h Mandatory

Get FRU LED Properties 3-24 PICMG 05h Mandatory Get LED Color Capabilities 3-25 PICMG 06h Mandatory Set FRU LED State 3-26 PICMG 07h Mandatory Get FRU LED State 3-27 PICMG 08h Mandatory Get Device Locator Record ID 3-29 PICMG 0Dh Mandatory AMC® Commands Set AMC Port State 3-27 PICMG 19h Mandatory Get AMC Port State 3-28 PICMG 1Ah Mandatory

IPMI Functions List · Command

Page 154 of the Emerson ATCA-S201 user manual — DESCRIPTION
Page 154 · click to enlarge
Page 154

15 IPMC Firmware Upgrade Procedure

This chapter provides the instruction for upgrading the IPMC (Intelligent Platform Management controller) firmware. If the ATCA-S201 requires new firmware, an upgrade can be performed remotely using a LAN connection to the self manager.

15.1 The ipmitool utility

Firmware upgrades are accomplished with ipmitool, a utility for managing IPMI- enabled devices. The utility is an open source derivative which is modified by the shelf management supplier.

The ATCA-S201 keeps a redundant copy of the firmware in the FLASH. Upgrades are reliable and reversible. A failure in the download (error or interruption) does not disturb the IPMC's ability to continue using the "old" firmware or its ability to restart the download process. The IPMC automatically fails back to the previous firmware if there is a problem when first running new code.

SYNOPSIS

The minimum information to complete a firmware upgrade is documented here.

$ ipmitool [-I|-H|-T|-B|-t|-b] hpm upgrade <firmware_file> $ ipmitool [-I|-H|-T|-B|-t|-b] hpm activate

DESCRIPTION

ipmitool lets you manage Intelligent Platform Management Interface (IPMI) functions of either a local or remote system using IPMI V1.5 and IPMI v2.0. Capabilities include printing FRU data, LAN configuration, sensor readings, and remote power control. OPTIONS

Table 77 ipmitool options relevant to firmware upgrades

-I <interface> Selects IPMI interface to use. Supported interfaces that are compiled in are visible in the usage help output. Use lan to designate Ethernet.

-H <address> Remote server address, can be IP address or hostname. This option is required for lan interfaces.

-T <address> If updating AMC, use this to specify optional bus address of the bridge device (ex: Carrier IPMB-0 address if updating an AMC)

-B <bus id> If updating an AMC, these this optional bus ID of the Bridge device (ex: 0 if updating through a IPMC

-t <address> IPMB-L address of the final target

-b <bus id> bus ID of the final target [0=IPMB-0(IPMC), 7=IPMB-L(AMC)]

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 15-1

Option Description

Page 155 of the Emerson ATCA-S201 user manual — COMMAND SYNTAX EXAMPLES
Page 155 · click to enlarge
Page 155

IPMC Firmware Upgrade Procedure

COMMAND SYNTAX EXAMPLES

EXAMPLE 1. The following example shows the command sequence for firmware upgrade of an AMC installed on a carrier: $ ipmitool -I lan -H 192.168.0.2 -T 0x82 -B 0 -t 0x74 -b 7 hpm upgrade hpm1fw.img $ ipmitool -I lan -H 192.168.0.2 -T 0x82 -B 0 -t 0x74 -b 7 hpm activate

Line 1 puts the new firmware in the flash device, where hpm1fw.img is the image. Line 2 is used to dynamically load and activate the new firmware.

EXAMPLE 2. The following example shows the command performing firmware upgrade on the carrier itself: $ ipmitool -I lan -H 192.168.0.2 -t 0x82 -b 0 hpm upgrade hpm1fw.img $ ipmitool -I lan -H 192.168.0.2 -t 0x82 -b 0 hpm activate

Line 1 puts the new firmware in the flash device, where hpm1fw.img is the image. Line 2 is used to dynamically load and activate the new firmware.

Page 156 of the Emerson ATCA-S201 user manual — RAID
Page 156 · click to enlarge
Page 156

16 Index

B

Bonding 47

create a LUN 81 create a target 80 remove a LUN 83

CIFs support See SMB CLI

blade status 45, 56 Overview 26, 34 scripting options 28 start/invoke 25 syntax examples .35, 36, 39, 40, 43, 45, 56, 59, 64,

Link agregation (802.3ad) See Bonding LVM (Logical Volume Manager)

create a logical device 73 create a logical volume 70 delete a volume 74 extend a volume 73 overview 67

72, 73, 76, 81, 91

D

DHCP See Ethernet Port Properties

M

MTU See Ethernet Port Properties

E

N

Broadast address 44 DHCP 43 Gateway 44 IP address 43 MTU 44 Subnet mask 43

NFS

Create an export 89

P

F

changing 23, 35 recover, reset 103

Updating blade firmware 97

R

H

RAID

overview 57, 63 supported RAID levels 60, 66 RS232

HTML login See Web GUI

default baudrate 21

6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 16-3

Show 4 more labels / short text on this page
iSCSI · Ethernet port properties · Password · Firmware
Page 157 of the Emerson ATCA-S201 user manual — W
Page 157 · click to enlarge
Page 157

S

VLAN

Create an export 91 Status

vconfig tool 45 view defined VLAN 46

Blade staus menu 54

W

U

Enable/disable 35

commands 30 environment variables 24, 31 Overview 30

Show 4 more labels / short text on this page
Index · SMB share · Web GUI · Uboot
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Emerson ATCA-S201

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson ATCA-S201

Be the first to ask — other owners or our team will answer.

Original document

Emerson ATCA-S201 manual PDF

157 pages·4.1 MB·Power Supply·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…