CAUTION !
Take care when securing and routing wires so they do not short to adjacent terminals or rear of thermostat. Personal injury and/or property damage may occur.
ATTENTION! This product does not contain mercury. How- ever, this product may replace a unit which contains mercury. Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing non-absorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded. Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container and return to White-Rodgers for proper disposal.
New Thermostat Terminal Designation
Other Manufacturers’ Terminal Designation
RH
M
R5
R
RC
R
R
MOUNTING AND WIRING
G
G
G
F
G
G
W
W
W
H
W
Y
Y
Y
Y6
Y
WARNING !
* These are four-wire, single-transformer systems. Factory installed jumper wire between the RH and RC terminals must remain in place.
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
1. Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit. If necessary, move the electric heat switch (see ELECTRIC HEAT SYSTEMS, above). 2. Connect wires beneath terminal screws on base using appro- priate wiring schematic (see figs. 2 through 7). 3. Place base over hole in wall and mark mounting hole locations on wall using base as a template. 4. Move base out of the way. Drill mounting holes. 5. Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. Place a level against bottom of base, adjust until level, and then tighten screws. (Leveling is for appear- ance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure base. 6. Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.
Thermostat installation and all components of the sys- tem shall conform to Class II circuits per the NEC code.
Heat Pump Systems
This thermostat is configured from the factory to operate a heat/ cool, fossil fuel (gas, oil, etc.), forced air system. It is configured correctly for any system that DOES NOT require the thermostat to energize the fan on a call for heat. If your system is an electric or heat-pump system that REQUIRES the thermostat to turn on the fan on a call for heat, locate the GAS/ELECTRIC switch (see fig. 1) and switch it to the ELECTRIC position. This will allow the thermostat to energize the fan immediately on a call for heat. If you are unsure if the heating/cooling system requires the thermostat to control the fan, contact a qualified heating and air conditioning service person.
Heating Systems
Battery Location
This thermostat is set to operate properly with a forced-air heating system. If you have a hydronic heating system (a system that heats with hot water or steam), you must set the thermostat to operate properly with your system. Change the second option in the configuration menu to SL (see CONFIGURATION MENU, page 5).
This thermostat requires 2 “AA” alkaline batteries to operate. If the word LO BATTERY is displayed, the batteries are low and should be replaced with fresh “AA” Energizer® alkaline batteries. To replace the batteries, install the batteries along the top of the base (see fig. 1). The batteries must be installed with the positive(+) ends to the right.
* *


JUMPER
WIRE

For 2-wire Heat only, attach to RH and W
Figure 2. Typical wiring diagram for heat only, 3-wire, single transformer systems
Figure 5. Typical wiring diagram for heat/cool, 5-wire, two-transformer systems
JUMPER
JUMPER
WIRE
WIRE
WIRE


* Reversing valve is energized when the system switch is in the COOL position
TRANSFORMER
Figure 3. Typical wiring diagram for cool only, 3-wire, single transformer systems
Figure 6. Typical wiring diagram for heat pump
with reversing valve energized in COOL

RED jumper wire (provided with thermostat) must be connected between thermostat RH and RC terminals for proper thermostat operation with this system.
JUMPER
WIRE
WIRE

* Reversing valve is energized when the system switch is in the HEAT position
TRANSFORMER
Figure 4. Typical wiring diagram for heat/cool, 4-wire, single transformer systems
Figure 7. Typical wiring diagram for heat pump
with reversing valve energized in HEAT
‡ The 24 Volt neutral connection to terminal C on the
thermostat is not required if the batteries are replaced once a year with fresh “AA” Energizer® alkaline batteries.


If at any time during testing your system does not operate properly, contact a qualified service person. Turn on power to the system.
If your system does not have a G terminal connection, skip to Heating System. 1. Move FAN switch to ON position. The blower should begin to operate. 2. Move FAN switch to AUTO position. The blower should stop immediately.
The Display

9 Indicates day of the week.
To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.
10 Flame icon ( ) is displayed when the SYSTEM switch is in the HEAT position. Snowflake icon ( )is displayed (non- flashing) when the SYSTEM switch is in the COOL position. Snowflake is displayed (flashing) if the thermostat is in lockout mode to prevent the compressor from cycling too quickly. 11 Displays “BATT” when the 2 “AA” batteries are low and should be replaced. Only “BATT” with “LO” in the minutes field are displayed when batteries are low with no system power.
12 Alternately displays current time and temperature. Displays “LO” in the minutes field when batteries are low. 13 The word “HOLD” is displayed when the thermostat is in the HOLD mode. “HOLD” is displayed flashing when the ther- mostat is in a temporary HOLD Mode. 14 Displays currently programmed set temperature (this is blank when SYSTEM switch is in the OFF position). 15 Displays FLTR when the system has run for the programmed filter time period as a reminder to change or clean your air filter.
Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. Your thermostat consists of two parts: the thermostat cover and the base. To remove the cover, pull it straight out from the base. To replace the cover, line up the cover with the base and press until the cover snaps onto the base.
CONFIGURATION MENU The configuration menu allows you to set certain thermostat operating characteristics to your system or personal require- ments. Press RUN to make sure the thermostat is in the run program mode, then press PRGM and RUN at the same time to enter the configuration menu. The display will show the first item in the configuration menu. The configuration menu table summarizes the configuration options. An explanation of each option follows. Press HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.
1 Raises temperature setting.
2 Lowers temperature setting.
3 TIME button.
4 PRGM (program) button.
5 RUN (run program) button.
6 HOLD temperature button.
7 FAN switch (ON, AUTO).
8 SYSTEM switch (COOL, OFF, HEAT).

CHECK THERMOSTAT OPERATION CONTINUED FROM FOURTH PAGE 5 5) Select filter replacement run time - The thermostat will display “FLTR” after a set time of operation. This is a reminder to change or clean your air filter. This time can be set from 0 to 1950 hours in 50 hour increments. A selection of 000 will cancel this feature. When “FLTR” is displayed, you can clear it by pressing HOLD and RUN at the same time. This resets the timer and starts counting the hours until the next filter change. Changing the time in the menu also resets the timer. 6) Select Compressor Lockout LOC OFF or ON - Selecting LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power. It will also wait 5 minutes minimum between cooling cycles. This is intended to help protect the compres- sor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the feature is already present in their system. When the compressor time delay occurs it will flash the (snowflake icon) for about five minutes then turn on the compressor. 7) Select Temperature Display Adjustment 4 LO to 4 HI - Allows you to adjust the room temperature display 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display tem- perature to match your previous thermostat. 8) Select F° or C° Readout - Changes the display readout to Centigrade or Fahrenheit as required.
Example: 1. You have selected 3:00 hours for the Temporary Hold time period. 2. With the thermostat set to HEAT or COOL, press HOLD for approximately five seconds until “HOLD” time (3:00 indicating 3 hours) appears as a setting reminder. 3. After releasing the button, “HOLD” on the display will blink. 4. Use or to set the temperature to your preference. The thermostat will maintain this temperature setting for 3 hours with “HOLD” blinking to remind you it is in Tempo- rary Hold. After 3 hours the thermostat will go back to the program temperature and “HOLD” will no longer blink or display. 2) Select FA or SL (Fast or Slow) Heating Cycle Rate - The FA setting is frequently used for gas, oil or electric heat. The SL setting produces a longer heating cycle which is normally for hot water or steam (hydronic) systems. Both settings produce very accurate temperature control and can be set to your personal preference. FA cycles the system just under 1°F and the SL setting cycles at approximately 1.5°F. 3) Select backlit display - The display backlight improves display contrast in low lighting conditions. Selecting backlight ON will keep the light on for a short period of time after any key is pressed. Selecting OFF will keep the light off. 4) Select Energy Management Recovery OFF or ON - Energy Management Recovery (EMR) causes the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint. Example: You select EMR and have your heating pro- grammed to 65° at night and 70° at 7 AM. If the building temperature is 65° the difference between 65° and 70° is 5°. Allowing 5 minutes per degree the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows more time per degree because it takes longer to reach temperature.
Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the thermostat.
* Press HOLD to advance to next item or TIME to move backwards to previous item

PROGRAMMING YOUR THERMOSTAT 6
This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.
AM
EXAMPLE:
This display window shows that for the 1st weekday period, the start time is 6:00 AM, and 70° is the programmed tempera- ture (this example reflects factory preprogramming).
3. Press or to change the displayed temperature to your selected temperature for the 1st heating program period. 4. Press TIME once (the programmed time will flash). Press or until your selected time appears. The time will change in 15 minute increments. When your selected time is dis- played, press TIME again to return to the change temperature mode. 5. Press PRGM once. The currently programmed start time and setpoint temperature for the 2nd heating program period will appear. 6. Repeat steps 3 through 5 to select the start time and heating temperature for the 2nd heating program period.
Follow these steps to enter the heating and cooling programs you have selected.
SAMPLE Heating/Cooling Schedule Plan (Factory Program)
SAMPLE Heating/Cooling Schedule Plan (Factory Program)



7. Repeat steps 3 through 5 for the 3rd and 4th heating program periods. Weekday heating programs are now complete. 8. Press PRGM once. “SA” will appear in the display, along with the start time for the 1st heating period and the currently programmed temperature for Saturday. 9. Repeat steps 3 through 7 to complete Saturday heating programming. 10.Press PRGM once. “SU” will appear on the display along with start time and currently programmed temperature for the 1st heating period for Sunday. Repeat steps 3 through 7 to complete Sunday heating programming.
Follow these steps to check your thermostat programming one final time before beginning thermostat operation. 1. Move SYSTEM switch to HEAT position. 2. Press PRGM to view the 1st weekday heating period time and temperature. Each time you press PRGM, the next heating period time and temperature will be displayed in sequence for weekday, then weekend program periods (you may change any time or temperature during this procedure). 3. Press RUN. 4. Move SYSTEM switch to COOL position. 5. Repeat step 2 to check cooling temperatures. 6. Press RUN to begin program operation.
11.When you have completed entering your heating program, press RUN.
YOUR THERMOSTAT IS NOW COMPLETELY PROGRAMMED AND READY TO AUTOMATICALLY PROVIDE MAXIMUM COM- FORT AND EFFICIENCY!
If the outside temperature is below 50°F, disconnect power to the cooling system before programming. En- ergizing the air conditioner compressor during cold weather may cause personal injury or property damage.
THERMAL DATA Setpoint Temperature Range:
ELECTRICAL DATA Electrical Rating:
0 to 30 VAC 50/60 Hz. or D.C. 0.05 to 1.2 Amps (Load per terminal) 1.5 Amps Maximum Total Load (All terminals combined)
45°F to 90°F (7°C to 32°C) Operating Ambient Temperature Range:
32°F to 105°F Operating Humidity Range:
0 to 90% RH (non-condensing) Shipping Temperature Range:
-40°F to 150°F
Reset Operation If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation you can reset the thermostat by pressing , and TIME at the same time. This resets the thermostat to the factory defaults. If the thermostat has power,
has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.
Batteries For optimum performance, we recommend replacing batteries once a year with fresh “AA” Energizer
® alkaline batteries.

The Emerson logo is a trademark and a service mark of Emerson Electric Co.