Model 3700 Transmitter (MVD) or Model 3350 Peripheral
Installation Instructions for Field-Mount
For technical support, phone the support center nearest you:

This quick reference guide explains basic installation guidelines for installing the Micro Motion
® Model 3350/3700 MVD applications platform.
For information on I.S. applications, refer to Micro Motion approval documentation.
For complete instructions about configuration, maintenance, and service, refer to the instruction manual shipped with the transmitter.
Improper installation in a hazardous area can cause an explosion.
For information about hazardous applications, refer to Micro Motion approval documentation, shipped with the transmitter or available from the Micro Motion web site.
Hazardous voltage can cause severe injury or death.
Install transmitter and complete all wiring before supplying power.
Improper installation could cause measurement error or meter failure.
Follow all instructions to ensure transmitter will operate correctly.
©2005, Micro Motion, Inc. All rights reserved. Micro Motion is a registered trademark of Micro Motion, Inc. The Micro Motion and Emerson logos are trademarks of Emerson Electric Co. All other trademarks are property of their respective owners.

This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this quick reference guide. Refer to the EC declaration of conformity for directives that apply to this product.
The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the web at www.micromotion.com/atex or through your local Micro Motion support center.
The Model 3350/3700 installation kit includes the parts shown in Figure 1.

4 x Lock washer
Transmitter can be oriented on bracket. See Step 3.
Mounting bracket

Choose a location for the transmitter based on the requirements described below.
Improper installation in a hazardous area could cause an explosion.
Install the transmitter in an area that is compatible with the rating on the approvals tag. See Figure 3.
Install the Model 3350/3700 according to specified limits:
See Figures 2, 3, and 4 for Model 3350/3700 dimensions.
To ensure personal and system safety, all tags attached to the housing must remain visible. Clean them as often as necessary. Replace tags that are damaged, missing, or worn. See Figure 3 for location of approvals tag.




2 x 2 13/17 (71) inches
(mm) 1 7/8 (48) 2 x 15/16 (24)
5 x 3/4–14 NPT or 5 x M20 x 1.5 – 6H
Maximum cable length from the sensor to the Model 3700 transmitter depends on the installation type and cable type:
If you are installing the Model 3350 applications peripheral in combination with a transmitter, the maximum cable length from the transmitter’s frequency output to the Model 3350’s frequency input is 500 feet (150 meters).



Cable type Wire gauge Maximum length
Micro Motion 9-wire Not applicable 60 feet (20 meters)
Micro Motion 4-wire Not applicable 1000 feet (300 meters)
20 AWG (0,5 mm 2) 500 feet (150 meters)
18 AWG (0,8 mm 2) 1000 feet (300 meters)
Cable from transmitter’s FO to Model 3350’s FI
Not applicable 500 feet (150 meters)
(1) Applies only to the Model 3300 applications peripheral when receiving frequency input from a remote Micro Motion transmitter such as an IFT9701 or RFT9739.

If the Model 3350/3700 carries an ATEX Zone 1 approval:
The Model 3350/3700 can be oriented on the mounting bracket as needed, and the display cover can be rotated on the applications platform. Figure 7 provides orientation examples.
To orient the Model 3350/3700:
To rotate the display cover, if needed, see the transmitter installation manual.

Conduit openings down

For flat-surface mounting, see Figure 8.
For pole mounting, see Figure 9.


2 x 5/16-inch U bolt for 2-inch pipe (user-supplied)

This step is required only for remote core processor with remote transmitter installations (see Figure 6). If you have a 4-wire remote installation, go to Step 6.
Figure 10 shows the remote core processor and mounting bracket. Using the mounting bracket, mount the core processor in a location compatible with the cable length requirements discussed in Step 1.
STEP 6. Connecting input and output wiring
Figure 11 shows the location of the wiring terminals on the Model 3350/3700.


Lockout device (not supplied with all units)
Non-intrinsically safe input/output wiring terminals (gray terminal block)
Intrinsically safe sensor wiring terminals
Wiring compartment Should remain closed
while power is on
Label for input/output wiring terminals


Model 3350/3700 with AC
Model 3350/3700 with DC


Terminal 9:
Terminal 9:
line (L or L2)
Terminal 10:
Terminal 10:
neutral (N or L1)
If you are installing the Model 3350 applications peripheral, this step is not required. Go to Step 8.
To connect the Model 3700 transmitter to a Micro Motion sensor, follow the instructions in this section.

The Model 3700 can be wired to the sensor in either of the following configurations:
a. Identify the wires in the 4-wire cable. The 4-wire cable supplied by Micro Motion consists of one pair of 18 AWG (0,75 mm
b. Connect the four wires from the core processor to the appropriate terminals on the transmitter. See Table 3 and Figure 13 (standard core processor) or Figure 14 (enhanced core processor). No bare wires should remain exposed. Do not ground the shield or drain wire(s) at the transmitter.
(1) Wire colors apply only to 4-wire cable supplied by Micro Motion.

4-wire cable Model 3700 terminals
Maximum cable length:
VDC+

16 RS-485B (Green) 15 RS-485A (White) 14 VDC– (Black) 13 VDC+ (Red)
4-wire cable Model 3700 terminals
Maximum cable length:

16 RS-485B (Green) 15 RS-485A (White) 14 VDC– (Black) 13 VDC+ (Red)

There are two phases to this procedure:
To wire the remote core processor to the transmitter:
- If you are using shielded cable, prepare the cable and apply shielded heat shrink as described in Step 4. The shielded heat shrink provides a shield termination suitable for use in the gland when using cable whose shield consists of foil and not a braid. Go to Step 2.
- If you are using armored cable, prepare the cable as described in Step 4, but do not apply heat shrink – omit Steps 4d, e, f, and g. Go to Step 2.


4 1/2 in (114 mm)
3/4 in (19 mm)
Gland nut Gland clamping
7/8 in (22 mm) 7/8 in (22 mm) Shielded heat shrink
a. Strip 4 1/2 inches (114 mm) of cable jacket.
b. Remove the clear wrap that is inside the cable jacket, and remove the filler material between the wires.
c. Remove the foil shield that is around the insulated wires, leaving 3/4 inch (19 mm) of foil or braid and drain wires exposed, and separate the wires.
d. Wrap the shield drain wire(s) around the exposed foil twice. Cut off the excess wire.

Shield drain wire(s) wrapped twice around exposed shield foil
e. Place the shielded heat shrink over the exposed shield drain wire(s). The tubing should completely cover the drain wires.
f. Without burning the cable, apply heat (250 °F or 120 °C) to shrink the tubing.
insert · Gland body


Shielded heat shrink completely covers exposed drain wires
g. Position gland clamping insert so the interior end is flush with the heat shrink.
h. Fold the cloth shield or braid and drain wires over the clamping insert and approximately 1/8 inch (3 mm) past the O-ring.

i. Install the gland body into the core processor housing conduit opening.



Power supply – (Black wire)
Twisting the core processor will damage the sensor.
Do not twist the core processor.
To wire the sensor to the remote core processor:
Allowing the shield drain wires to contact the sensor junction box can cause meter errors.
Do not allow the shield drain wires to contact the sensor junction box.

a. Identify the components shown in Figure 10.
a. Remove the core processor’s end-cap.
b. Insert the 9-wire cable through the conduit opening.
c. Connect the wires to the plugs supplied with the core processor.
d. Insert the plugs into the sockets inside the lower conduit ring. See Figure 15.
9-wire cable from sensor
Black (Drains from all wire sets)
Blue Gray Orange Violet Yellow
a. Ground the shield drain wires (the black wire) only on the core processor end, by connecting it to the ground screw inside the lower conduit ring. Do not ground to the core processor’s mounting screw. Do not ground the cable at the sensor junction box.

If using shielded or armored cable:
a. Ground the shield drain wires (the black wire) only on the core processor end, by connecting it to the ground screw inside the lower conduit ring. Do not ground to the core processor’s mounting screw. Do not ground the cable at the sensor junction box.
b. Ground the cable braid on both ends, by terminating it inside the cable glands.
Damaging the wires that connect the transmitter to the sensor can cause measurement error or meter failure.
To reduce the risk of measurement error or meter failure, when closing the housings on the sensor and core processor, make sure that the wires are not caught or pinched.
CAUTION
Improper wiring installation can cause device failure or measurement error.

Connect the Model 3350/3700 to a power supply as follows:





©2005, Micro Motion, Inc. All rights reserved. P/N 20001008, Rev. B
Visit us on the Internet at www.micromotion.com
Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado 80301 T (303) 527-5200 (800) 522-6277 F (303) 530-8459
Micro Motion Europe Emerson Process Management Veenendaal The Netherlands T +31 (0) 318 495 670 F +31 (0) 318 495 689
Micro Motion Asia Emerson Process Management 1 Pandan Crescent Singapore 128461 Republic of Singapore T (65) 6777-8211 F (65) 6770-8003
Micro Motion United Kingdom Emerson Process Management Limited Horsfield Way Bredbury Industrial Estate Stockport SK6 2SU U.K. T 0800 966 180 F 0800 966 181
Micro Motion Japan Emerson Process Management Shinagawa NF Bldg. 5F 1-2-5, Higashi Shinagawa Shinagawa-ku Tokyo 140-0002 Japan T (81) 3 5769-6803 F (81) 3 5769-6843
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.